810026 KSU Conduit.pub

201410
Technical Data Sheet
Page 1
Metallic Systems - Stainless Steel
KSU - Uncovered Conduit
Technical Characteristics
Conforms to
BSI Kitemark KM-90009
Low voltage directive
Approvals and Standards
Degree of mechanical protection
Very high flexibility & fatigue life
Degree of protection
IP40 - As standard with GFMS fittings
UV protection
Very High
Finish
Self Coloured
Application
Indoors - light industrial, buildings marine, corrosive environments
Normal operating temperature range
Application
Min Temp
Max Temp
Static
- 65°C
+350°C
Dynamic
- 45°C
+250 °C
For use with - Fitting range
Fire performance
KF-E - GFMS
Test Standard
Performance Rating
Not Rated
Not Rated
Testing data
Click or See page 3
Type of material
Stainless Steel AISI 316L
Inherent
Low Fire Hazard
Resistance to
Flame
Propagation
Image
Cable Management Products Ltd.
CMG House - Station Road - Coleshill - B46 1HT - United Kingdom
Tel: +44(0)1675 468 222 - Fax: +44(0)1675 464 930
Technical Support e-mail: [email protected] - www.kopex.co.uk
The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.
201410
Technical Data Sheet
Page 2
Metallic Systems - Stainless Steel
KSU - Uncovered Conduit
Technical & Dimensional Data
Conduit size metric
(mm)
10
12
16
20
25
32
40
-
1/4”
5/16”
3/8”
1/2”
3/4”
1”
1 1/4”
-
KSU01*
KSU02*
KSU03*
KSU04*
KSU05*
KSU06*
KSU07*
-
10/30
10/30
10/30
10/30
10/30
10/20
10/20
-
A - Outside diameter
(mm)
9.6
12.8
16.1
20.2
24.7
32.0
40.0
-
B - Inside diameter
(mm)
7.0
10.0
12.9
17.0
21.1
28.4
36.4
-
C - Static bend radius
(mm)
20.0
20.0
24.0
32.0
45.0
55.0
65.0
-
Average weight
(KG/100m)
9.5
12.9
15.6
21.7
27.0
36.0
45.5
-
Conduit size US trade
(inches)
Part code
Coil length (m)
*For ordering code add coil length to part code - e.g KSU0410
Cable Management Products Ltd.
CMG House - Station Road - Coleshill - B46 1HT - United Kingdom
Tel: +44(0)1675 468 222 - Fax: +44(0)1675 464 930
Technical Support e-mail: [email protected] - www.kopex.co.uk
The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.
201410
Technical Data Sheet
Page 3
Metallic Systems - Stainless Steel
KSU - Uncovered Conduit
BS EN 61386 Classification
KSU04
Fitting
Compression
Impact
Min
temp
Max
temp
bending
electrical
IP
solids
IP
water
GFMS
4
4
5
6
4
0
4
0
Corrosion Tensile
4
4
Non-flame
Propogating
Suspended
load
1
5
Mechanical Properties
Test Type
Methods / Standards Requirements
Value
Crush Strength @ 23°C
IEC61386-1
<25% crush >90% recovery
>1250N
Impact Strength @ 23 °C
IEC61386-1
No Cracks <20% deformation
>20J
Impact Strength @-45 °C
IEC61386-1
No Cracks. <20% deformation
>20J
Tensile Strength
IEC61386-1
With GFMS Type Fitting
>1000N
Ultimate pull-out of GFMS Fitting
1450N
IEC61386-23
5000 cycles minimum
4xOD
Test Type
Methods / Standards
Requirements
Value
Minimum Temperature
IEC61386-23
Dynamic 5000 cycles
-45°C
Maximum Temperature
IEC61386-23
Dynamic 5000 cycles
250°C
Minimum Static
Permanent Use
-65°C
Maximum Static
Permanent Use
350°C
Tensile Strength
Dynamic Bend radius @ -45 °C
Thermal Properties
Chemical Resistance Chart
Key:
Suitable :
Limited Suitability :
Unsuitable :
Not Tested :
Astm No.1
Diesel oil
Methyl Bromide
Sulphur Dioxide (Gas)
Astm No.2
Diethylamine
MEK
Sulphuric Acid (10%)
Astm No.3
Ethanol
Nitric Acid (10%)
Sulphuric Acid (70%)
Acetic Acid (10%)
Ether
Nitric Acid (70%)
Toluene
Acetone
Ethylamine
Oxalic Acid
Transformer Oil
Aluminium Chloride
Ethylene Glycol
Ozone (Gas)
1,1,1-Trichloroethane
Aniline
Ethyl Ethanoate
Paraffin oil
Trichloroethylene
Benzaldehyde
Freon 32
Petrol
Turpentine
Benzene
Hydrochloric Acid (10%)
Phenol
Vegetable Oil
Carbon tetrachloride
Hydrochloric Acid (36%)
Sea Water
Vinyl Acetate
Chlorine water
Hydrogen Peroxide (35%)
Silver Nitrate
Water
Chloroform
Hydrogen Peroxide (87%)
Skydrol
White Spirit
Citric Acid
Lactic Acid
Sodium Chloride
Zinc Chloride
Copper Sulphate
Lubricating oil
Sodium Hydroxide (10%)
Cresol
Methanol
Sodium Hydroxide (60%)
The information above is given as a guide only and is based on published technical data and experience. The chemical resistance of the above products is dependant
on factors such as chemical exposure, concentration of the chemical and temperature. The above chemicals are valid for a temperature of 23°C. Use of the above
table is at the users own discretion and risk. Those using it must satisfy themselves that their application presents no health and safety risks. The end user should
assess compatibility with their application and contact Thomas & Betts for further information.
ADHERENCE TO THE CURRENT WIRING REGULATIONS BS7671 OR NEC WIRING REGULATIONS (FOR USA) IS STRONGLY
ADVISED.
MINIMUM BEND RADIUS FOR FLEXING IS DEPENDANT UPON MINIMUM TEMPERATURE, BENDING FREQUENCY AND CHEMICAL
ENVIRONMENT.
Cable Management Products Ltd.
CMG House - Station Road - Coleshill - B46 1HT - United Kingdom
Tel: +44(0)1675 468 222 - Fax: +44(0)1675 464 930
Technical Support e-mail: [email protected] - www.kopex.co.uk
The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.