201410 Technical Data Sheet Page 1 Metallic Systems - Stainless Steel KSU - Uncovered Conduit Technical Characteristics Conforms to BSI Kitemark KM-90009 Low voltage directive Approvals and Standards Degree of mechanical protection Very high flexibility & fatigue life Degree of protection IP40 - As standard with GFMS fittings UV protection Very High Finish Self Coloured Application Indoors - light industrial, buildings marine, corrosive environments Normal operating temperature range Application Min Temp Max Temp Static - 65°C +350°C Dynamic - 45°C +250 °C For use with - Fitting range Fire performance KF-E - GFMS Test Standard Performance Rating Not Rated Not Rated Testing data Click or See page 3 Type of material Stainless Steel AISI 316L Inherent Low Fire Hazard Resistance to Flame Propagation Image Cable Management Products Ltd. CMG House - Station Road - Coleshill - B46 1HT - United Kingdom Tel: +44(0)1675 468 222 - Fax: +44(0)1675 464 930 Technical Support e-mail: [email protected] - www.kopex.co.uk The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. 201410 Technical Data Sheet Page 2 Metallic Systems - Stainless Steel KSU - Uncovered Conduit Technical & Dimensional Data Conduit size metric (mm) 10 12 16 20 25 32 40 - 1/4” 5/16” 3/8” 1/2” 3/4” 1” 1 1/4” - KSU01* KSU02* KSU03* KSU04* KSU05* KSU06* KSU07* - 10/30 10/30 10/30 10/30 10/30 10/20 10/20 - A - Outside diameter (mm) 9.6 12.8 16.1 20.2 24.7 32.0 40.0 - B - Inside diameter (mm) 7.0 10.0 12.9 17.0 21.1 28.4 36.4 - C - Static bend radius (mm) 20.0 20.0 24.0 32.0 45.0 55.0 65.0 - Average weight (KG/100m) 9.5 12.9 15.6 21.7 27.0 36.0 45.5 - Conduit size US trade (inches) Part code Coil length (m) *For ordering code add coil length to part code - e.g KSU0410 Cable Management Products Ltd. CMG House - Station Road - Coleshill - B46 1HT - United Kingdom Tel: +44(0)1675 468 222 - Fax: +44(0)1675 464 930 Technical Support e-mail: [email protected] - www.kopex.co.uk The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. 201410 Technical Data Sheet Page 3 Metallic Systems - Stainless Steel KSU - Uncovered Conduit BS EN 61386 Classification KSU04 Fitting Compression Impact Min temp Max temp bending electrical IP solids IP water GFMS 4 4 5 6 4 0 4 0 Corrosion Tensile 4 4 Non-flame Propogating Suspended load 1 5 Mechanical Properties Test Type Methods / Standards Requirements Value Crush Strength @ 23°C IEC61386-1 <25% crush >90% recovery >1250N Impact Strength @ 23 °C IEC61386-1 No Cracks <20% deformation >20J Impact Strength @-45 °C IEC61386-1 No Cracks. <20% deformation >20J Tensile Strength IEC61386-1 With GFMS Type Fitting >1000N Ultimate pull-out of GFMS Fitting 1450N IEC61386-23 5000 cycles minimum 4xOD Test Type Methods / Standards Requirements Value Minimum Temperature IEC61386-23 Dynamic 5000 cycles -45°C Maximum Temperature IEC61386-23 Dynamic 5000 cycles 250°C Minimum Static Permanent Use -65°C Maximum Static Permanent Use 350°C Tensile Strength Dynamic Bend radius @ -45 °C Thermal Properties Chemical Resistance Chart Key: Suitable : Limited Suitability : Unsuitable : Not Tested : Astm No.1 Diesel oil Methyl Bromide Sulphur Dioxide (Gas) Astm No.2 Diethylamine MEK Sulphuric Acid (10%) Astm No.3 Ethanol Nitric Acid (10%) Sulphuric Acid (70%) Acetic Acid (10%) Ether Nitric Acid (70%) Toluene Acetone Ethylamine Oxalic Acid Transformer Oil Aluminium Chloride Ethylene Glycol Ozone (Gas) 1,1,1-Trichloroethane Aniline Ethyl Ethanoate Paraffin oil Trichloroethylene Benzaldehyde Freon 32 Petrol Turpentine Benzene Hydrochloric Acid (10%) Phenol Vegetable Oil Carbon tetrachloride Hydrochloric Acid (36%) Sea Water Vinyl Acetate Chlorine water Hydrogen Peroxide (35%) Silver Nitrate Water Chloroform Hydrogen Peroxide (87%) Skydrol White Spirit Citric Acid Lactic Acid Sodium Chloride Zinc Chloride Copper Sulphate Lubricating oil Sodium Hydroxide (10%) Cresol Methanol Sodium Hydroxide (60%) The information above is given as a guide only and is based on published technical data and experience. The chemical resistance of the above products is dependant on factors such as chemical exposure, concentration of the chemical and temperature. The above chemicals are valid for a temperature of 23°C. Use of the above table is at the users own discretion and risk. Those using it must satisfy themselves that their application presents no health and safety risks. The end user should assess compatibility with their application and contact Thomas & Betts for further information. ADHERENCE TO THE CURRENT WIRING REGULATIONS BS7671 OR NEC WIRING REGULATIONS (FOR USA) IS STRONGLY ADVISED. MINIMUM BEND RADIUS FOR FLEXING IS DEPENDANT UPON MINIMUM TEMPERATURE, BENDING FREQUENCY AND CHEMICAL ENVIRONMENT. Cable Management Products Ltd. CMG House - Station Road - Coleshill - B46 1HT - United Kingdom Tel: +44(0)1675 468 222 - Fax: +44(0)1675 464 930 Technical Support e-mail: [email protected] - www.kopex.co.uk The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.
© Copyright 2024 ExpyDoc