Flow Meter Calibration Services Standard Primary and Secondary COMPLETE CALIBRATION SOLUTIONS Flow Dynamics primary standard calibration laboratory, by Badger Meter, offers precision calibrations in air, gases, water, solvent and blended oil. These calibrations are sought after by automotive, aerospace, industrial process, OEM, and custody transfer customers. Flow Dynamics can calibrate any flow meter from any manufacturer within the scope of our accreditation. We provide certified calibration data sheets, comprehensive meter historical data, annual reminders, and a 7-day standard turnaround, with expedites upon request. UVC calibrations may take longer due to the custom blending of fluids. Secondary standard calibrations can be done on site using master meters installed in existing piping. This enables the meter to be calibrated using the actual process fluid, without removal from piping, eliminating system variables that are sometimes difficult to reproduce in the calibration lab. CREDENTIALS Flow Dynamics in Scottsdale AZ meets the highest standards, having achieved accreditations to ISO/IEC 17025, certified compliant to ANSI/NCSL Z540 and NIST Handbook 150 by the National Voluntary Laboratory Accreditation Program (NVLAP Lab Code 200668-0). Working with an NVLAP-accredited flow calibration laboratory delivers the quality and consistency to support the most critical flow measurement applications. Our quality management systems conforms to ISO 9001 and ISO/IEC 17025. FLOW CALIBRATION CAPABILITY Our laboratory uses primary standard positive displacement liquid calibrators and bell provers for gas. A sonic nozzle bank is used for high pressure gas calibrators. Locations • Flow Dynamics, Scottsdale, Arizona ◊ NVLAP (Lab Code 200668-0) accredited • Features Benefits Primary standard liquid and gas calibrators Superior calibration uncertainties Secondary standard sonic nozzles Simulated gas densities up to 400 psia (2758 kPa absolute) Certified calibration data sheets Certificate of calibration for regulatory compliance NVLAP (Lab Code 200668-0) accredited Published uncertainty statements audited by NVLAP biannually Comprehensive historical data Meter calibration history maintained for life Multiple liquid and gas calibrators Calibrates all types of fluids Extensive fluid blending capability Matches actual process fluid viscosity to improve accuracy CAL-DS-00040-EN-04 (April 2014) NTK-COX, Hachioji-City, Tokyo, Japan ◊ Calibrators have a certificate of calibration by Flow Dynamics, NVLAP (Lab Code 200668-0) ◊ Complies with ISO/IEC 17025 (accreditation pending) Service Data Sheet Primary and Secondary Standard Flow Meter Calibration Services FLOW DYNAMICS NVLAP (LAB CODE 200668-0) Hydrocarbon Primary Standard Calibration Solvent and hydrocarbon blends 0.6…1000 cSt or mm2/s Flow Range 0.003…1500 gpm (0.011…5678 lpm) Viscosity 0.60…1000 cSt or mm2/s Uncertainty ± 0.034% of reading Repeatability ± 0.012% of reading FLOW CALIBRATION INFORMATION Flow Dynamics records flow meter calibration data by the meter serial number allowing us to retrieve previous calibration history for comparison to the current calibration information. These records are stored over the life of the meter. If this is the first time a meter has been calibrated, the record system requires setup information at the time the order is placed. Hydrocarbon Field Calibration, Secondary Standard Flow Range 0.025…1500 gpm (0.946…5678 lpm) Viscosity Based on customer’s fluid Uncertainty ± 0.15% of reading Repeatability ± 0.02% of reading • AS FOUND: Meter is calibrated, as received, with no repairs or adjustments • AS LEFT: Meter is calibrated after a repair or cleaning Calibration Instructions Water Primary Standard Calibration Water 1.0 cSt or mm2/s Flow Range 0.03…300 gpm (0.011…1135 lpm) Viscosity 1.0 cSt or mm2/s Uncertainty ± 0.033% of reading Repeatability ± 0.05% of reading Water Field Calibration, Secondary Standard Flow Range 0.03…300 gpm (0.011…1135 lpm) Viscosity 1.0 cSt or mm2/s Uncertainty ± 0.15% of reading Repeatability ± 0.02% of reading Gas Primary Standard Calibration • AS LEFT, SYSTEM CHECK: Meter and flow processor are calibrated after a repair, adjustment or reprogramming has been performed Serial Number Becomes history calibration data file name Model Number Used to retrieve manufacturer product manuals and specifications Meter Type Technology types such as: Coriolis, mag, turbine, rotameters, thermal mass, cone Fluid Type Water, solvent, blended oil, ambient air, gases at various densities Flow Range 0.00035…1000 scfm (0.00991…28,317 slpm) air Operating Temperature Range Requires minimum and maximum in Centigrade or Fahrenheit Pressure Partial vacuum…400 psia (2758 kPa) Specific Gravity Required for mass meters Uncertainty ± 0.20% of reading Flow Range Repeatability ± 0.10% of reading Minimum and maximum, units of measure, multiple viscosity or UVC calibrations Number of Calibration Data Points 6, 10, 20, 30, or K factor calibration Required Accuracy Per manufacturer’s specification Meter Signal Output Raw, digital, analog, or visual Calibration Interval Customer Service will email calibration reminders based on calibration interval Gas Secondary Standard • Gas correlations for toxic gases Gas up to 400 psia (2758 kPa absolute) • AS FOUND, SYSTEM CHECK: Meter and flow processor are calibrated, as received, with no reprogramming or repairs Sonic Nozzles • Recommended for helium, nitrogen, argon, hydrogen, and methane Flow Range 0.1…400 scfm (2.83…11,327 slpm) Pressure 400 psia (2758 kPa) maximum Uncertainty ± 0.35% of reading Repeatability ± 0.15% of reading NNOTE: Flow Dynamics re-scales the electronics and reprograms the flow processor, which guarantees that the flow meter system is fully calibrated and ready for installation. Gas Field Calibration, Secondary Standard Page 2 Flow Range 0.1…1000 scfm (2.83…28,317 slpm) Pressure Partial vacuum…400 psia (2758 kPa) Uncertainty ± 0.35% of reading Repeatability ± 0.15% of reading April 2014 Primary and Secondary Standard Flow Meter Calibration Services Return Material Authorization Number (RMA) ADDITIONAL SERVICES The Return Material Authorization Number (RMA) is the order number. It must be placed on the shipping container to identify the meter when it reaches our receiving department. The RMA is issued at the time the order is placed and will track the meter through the calibration process. A file is set up in the database using the RMA number to place notes, purchase order documents, administrative details, or drawings pertaining to the calibration process. • Onsite flow meter calibrations • Onsite Primary Standard Calibrator NVLAP (Lab Code 200668-0) Accredited Certificate • Research and development testing DELIVERY TIME • Hazardous fluids correlation ◊ Time weigh ◊ Positive displacement Our standard calibration delivery time is 10 business days. Same day calibrations are available with an expedite fee. Every effort is made to return the flow meter promptly pending the degree of calibration difficulty and fluid preparation requirements. Flow Dynamics tracks the calibration process and continually improves on the standard delivery commitment to achieve rapid returns. Certificate of Calibration www.badgermeter.com 15555 North 79th Place • Scottsdale, AZ 85260 • Phone: (480) 948 -3789 • Fax: (480) 948 -3610 • [email protected] HONG KONG EVERBLOOMING INTL CO LTD CX35874 - X14892 Customer Name: Report # Sooner Air Freight Int’l Ltd Unit 7,Corp Square, 8 Lam Lok Street KLN BAY Hong Kong Customer Address: 13EB0205COX Customer PO # NRPC 12 2/21/2013 Model # Cal Date: X14892 Serial # Customer Re-Cal Date: PULSE (Collect Raw Data) 72.1 Deg F Signal: Lab Temp: FDP-002 27.3% Calibration Procedure: Lab Relative Humidity: Luis Calibration Tech: MIL-C-7024 T2 0.76 Fluid Specifications: Specific Gravity: 80 1.12 Temperature (F): Viscosity (CSTKS): Notes, Adjustments & Repairs Calibration Results (Initial Calibration) Test Point # Frequency Flow Rate Roshko # Strouhal # Meter Temp Viscosity Density Flow Rate Hz GPM Hz/cstk pul/gal Deg. F cStks g/cc LPM 1 10.5941 0.23290 10.1597 2729.48 72.223 1.0428 0.7662 0.88161 2 10.5995 0.23292 10.1649 2730.62 72.223 1.0428 0.7662 0.88169 3 16.4760 0.35749 15.8004 2765.43 72.224 1.0428 0.7666 1.35326 4 16.4773 0.35751 15.8017 2765.55 72.224 1.0428 0.7666 1.35331 5 23.0864 0.49779 22.1398 2782.83 72.229 1.0428 0.7665 1.88435 6 23.0878 0.49790 22.1411 2782.42 72.229 1.0428 0.7665 1.88474 7 31.8261 0.68334 30.5241 2794.65 72.239 1.0427 0.7665 2.58671 8 31.8233 0.68336 30.5214 2794.30 72.244 1.0427 0.7665 2.58681 9 45.9753 0.98154 44.0817 2810.58 72.207 1.0430 0.7665 3.71553 10 45.9764 0.98158 44.0913 2810.53 72.224 1.0428 0.7665 3.71569 11 65.0253 1.38527 62.2155 2816.58 71.909 1.0452 0.7665 5.24383 12 65.0929 1.38719 62.2802 2815.61 71.909 1.0452 0.7665 5.25109 13 92.3185 1.97035 88.2532 2811.37 71.782 1.0461 0.7665 7.4586 14 92.7150 1.97801 88.7088 2812.52 71.909 1.0452 0.7665 7.4876 15 126.727 2.71355 121.228 2802.25 71.876 1.0454 0.7665 10.2719 16 126.986 2.71960 121.429 2801.72 71.829 1.0458 0.7665 10.2948 17 172.915 3.72060 165.032 2788.63 71.567 1.0478 0.7668 14.084 18 173.020 3.72232 165.100 2789.03 71.539 1.0480 0.7668 14.0905 19 249.704 5.39233 238.001 2778.54 71.382 1.0492 0.7668 20.4122 20 250.070 5.39867 238.304 2779.35 71.347 1.0494 0.7668 20.4362 21 353.158 7.64305 335.772 2772.47 71.032 1.0518 0.7669 28.9321 22 353.580 7.65082 336.141 2772.96 71.016 1.0519 0.7669 28.9615 23 487.881 10.5643 462.716 2770.99 70.694 1.0544 0.7669 39.9901 24 488.960 10.5857 464.180 2771.49 70.824 1.0534 0.7669 40.0714 25 724.643 15.6740 686.287 2773.97 70.499 1.0559 0.7669 59.3325 26 725.055 15.6826 685.830 2774.01 70.321 1.0572 0.7669 59.3651 27 986.019 21.3207 976.576 2775.36 76.755 1.0098 0.7669 80.7077 28 993.053 21.4722 982.275 2775.43 76.571 1.0111 0.7668 81.281 29 1406.85 30.3943 1390.06 2777.71 76.414 1.0122 0.7668 115.055 30 1412.22 30.5055 1393.71 2778.13 76.245 1.0134 0.7668 115.476 Standards Used in Calibration Standard # Description Serial # ReCal Date FDI-180 30 GPM Liquid Prover NA 8/12/2013 The instrument referenced above was calibrated using standards traceable to the National Institute of Standards and Technology. Calibration reports for references maintained by Badger Meter, Inc. are available upon request to the customer of this calibration report. The volumetric flow rates reported are within a best uncertainty of +/- .037% of reading (Represents an expanded uncertainty using a coverage factor, k = 2, at an approximate level of confidence of 95%) and applies to calibration equipment only and does not apply to the UUT ( Unit Under Test). Badger Meter, Inc. Flow Dynamics calibration services are accredited by NVLAP (Lab Code 200668-0) to ISO/IEC 17025:2005 (NIST Handbook 150) and are compliant to ANSI/NCSLZ540-1-1994; Part 1. This certificate is not an endorsement by NVLAP, NIST or an agency of the federal government. The results reported relate only to the item(s) calibrated as described above. This report may not be reproduced, except in full, without the written approval of Badger Meter, Inc.. I certify the accuracy of this Calibration Report: Andrew Yee Name Calibration Engineer Title Signature Doc Nbr: CRF-002 Rev: F Report #:CX35874 - X14892 Page 1 of 1 April 2014 Page 3 Control. Manage. Optimize. FLOW DYNAMICS is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved. www.badgermeter.com The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0 Europe, Middle East Branch Office | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503 Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411 Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01 Asia Pacific | Badger Meter | 80 Marine Parade Rd | 21-04 Parkway Parade | Singapore 449269 | +65-63464836 China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412
© Copyright 2024 ExpyDoc