CATALOGUE CENTRIFUGATION 2014 / 2015 ULTRACENTRIFUGEUSES ULTRACENTRIFUGEUSE DE TABLE CENTRIFUGEUSES HAUTE VITESSE CENTRIFUGEUSES GRANDE CAPACITÉ CENTRIFUGEUSES ROTORS ADAPTATEURS TUBES BOUTEILLES ACCESSOIRES Brilliance at every turn. ULTRACENTRIFUGES PRECISION-MADE PERFORMANCE. BR-8101Q Ultracentrifugation Without limitation. Starting with the innovations created by our founder, Arnold O. Beckman Ph.D., Beckman Coulter has lived at the forefront of the technology that continues to help improve life for all of humankind. Our foray into the world of ultracentrifugation is no different. In fact, we introduced the first commercial ultracentrifuge in 1947. Since then, our elite line of ultracentrifuges has attained incredible levels of speed and sophistication, without sacrificing usability. Not unlike the rest of our portfolio of products, our ultracentrifugation solutions certainly live up to the Beckman Coulter name—a name in which laboratories around the world continue to have the utmost confidence. www.beckmancoultercentrifugation.com S ince the introduction of the first commercial Rotors with the BioCertified symbol have been tested to ultracentrifuge in 1947 — the classic Beckman demonstrate containment of aerosols under normal operating Model L — Beckman Coulter has been at the conditions of the associated Beckman Coulter centrifuge forefront of centrifuge innovation. Although the physics of this basic separation technique never change, Beckman when used and maintained as instructed. Following the centrifuge descriptions, listings of their Coulter continually designs new and innovative rotors and rotors are included with information on speed and g-force accessories, and develops advanced methods that allow capability. Also included is information on tubes and bottles the forces of centrifugation to be applied in new ways. that can be used and the adapters they require. This centrifuge product selection guide is designed to Tubes and bottles are cross-referenced in a separate help you determine the most efficient centrifuge tools for section which provides details on tube materials, chemical your laboratory. compatibility, tube designs, and tube closure options. Each section begins with a brief description of instru- A reference section at the back of the guide includes ments that Beckman Coulter offers within that centrifuge quick-reference charts on instrument and tube selection, category. Because biocontainment is a major concern in as well as frequently used formulas. today’s laboratories, Beckman Coulter provides a number of options that address this issue. Special BioSafe instruments and accessories are available across our centrifuge product line and are identified with the following icons: BioSafe and BioSafety are terms intended to describe the enhanced biocontainment features of our products. BioCertified is a term used to describe our products which have been tested and validated to demonstrate containment of microbiological aerosols by an independent, third-party facility (Health Protection Agency, Porton Down, UK or USAMRIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and, thus, containment. BioEnhanced is a term intended to describe our products’ enhanced level of biocontainment by design. Beckman Coulter Ultracentrifuge i www.beckmancoultercentrifugation.com Table of Contents Ultracentrifugation Ultracentrifuge Descriptions Optima X Series Floor Model Preparative ...................... 1-2 Optima MAX Series Tabletop Preparative ...................... 1-4 Airfuge Air-Driven Micro-Ultracentrifuge ...................... 1-6 Instrument Classifications; Speed Reductions; Rotor Designations............................................................. 1-7 k Factors; Centrifugal Forces ............................................. 1-7 Tube Kits; Use of Small Tubes; g-Max System ................. 1-7 Quick-Reference Guide to Instrument Classification Rotor Compatibility ........................................................... 1-8 Beckman Coulter Floor Model Ultracentrifuge Rotors by Use ................................................................................ 1-9 Rotors for Floor Model Preparative Ultracentrifuges Fixed-Angle Rotors ....................................................... 1-10 NVT Near-Vertical Tube Rotors .................................... 1-20 Vertical-Tube Rotors...................................................... 1-24 Swinging-Bucket Rotors ............................................... 1-28 Continuous-Flow Rotor ................................................. 1-36 Zonal Rotors .................................................................. 1-37 Rotors for Tabletop Ultracentrifuges Quick-Reference Guide to Rotor Specifications and Tabletop Ultracentrifuge Compatibility......................... 1-40 Fixed-Angle Rotors ....................................................... 1-42 NVT Near-Vertical Tube Rotors .................................... 1-54 Swinging-Bucket Rotors ............................................... 1-57 Rotors for Airfuge Air-Driven Micro-Ultracentrifuges Fixed-Angle Rotors ....................................................... 1-59 Chylomicron Rotor ........................................................ 1-61 Batch Rotor .................................................................... 1-61 Electron Microscopy Particle-Counting Rotor .............. 1-62 ii Tubes and Bottles Tubes and Bottles for Every Application ........................... 2-1 Tube Selection Considerations Compatibility of Tube Material with Solvents and Sample ....................................................... 2-2 Gradient Formation and Fractionation ............................ 2-2 High-Temperature Centrifugation ................................... 2-2 Tube Sizes ....................................................................... 2-2 Tube Cleaning, Sterilization, and Reuse ......................... 2-2 Tube Closures .................................................................. 2-3 OptiSeal Tubes ................................................................ 2-3 Quick-Seal Tubes ............................................................ 2-3 A Quick Reference Chart to Tube Materials and Their Properties.................................................................. 2-4 Tubes and Bottles (Listed by Volume) ............................... 2-5 Bottle Assemblies with Three-Piece Caps ......................... 2-8 Tube Cap Assemblies and Parts ......................................... 2-9 Tools, Accessories, and Supplies Tools and Supplies for Preparative Ultracentrifuge Rotors Tools for Fixed-Angle Rotors ......................................... 3-2 Tools for Vertical-Tube and NVT Rotors ........................ 3-4 Tools for Swinging-Bucket Rotors .................................. 3-4 Tools for Zonal Rotors .................................................... 3-4 Supplies ........................................................................... 3-5 Tools and Accessories for Quick-Seal Tubes Tools for Quick-Seal Tubes ............................................. 3-5 Quick-Seal Tube Racks ................................................... 3-6 Tools for OptiSeal Tubes ................................................... 3-6 Cordless Tube Topper ........................................................ 3-7 Tube Slicer—for Preparative Ultracentrifuge Tubes ......... 3-8 CentriTube Slicer—for Micro Ultracentrifuge Tubes ........ 3-8 Rotor Cleaning Kit ............................................................. 3-9 Fraction Recovery System ............................................... 3-10 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Table of Contents Reference Guide to Centrifuge Selection............................................ 4-2 How To Choose a Rotor The Importance of k Factor ............................................. 4-4 Rotor Material ................................................................. 4-4 Swinging-Bucket (SW) Rotors........................................ 4-4 Fixed-Angle (FA) Rotors ................................................ 4-4 Vertical-Tube (VT) Rotors .............................................. 4-4 NVT Near-Vertical Tube Rotors...................................... 4-4 Continuous-Flow/Zonal Rotors ....................................... 4-4 Particle Separation in SW, FA, NVT and VT Rotors ......... 4-5 Preparative Ultracentrifuge Rotor Recommendations for Key Applications .......................................................... 4-6 Gradient Materials .......................................................... 4-7 Commonly Used Gradient Materials with Their Solvents ................................................................. 4-8 Density, Refractive Index, and Concentration Data—CsCl at 25°C ........................................................ 4-9 Density, Refractive Index, and Concentration Data—Sucrose at 20°C ................................................. 4-10 Density Conversion for Cesium and Rubidium Salts at 20°C .......................................... 4-11 Useful Formulas ............................................................... 4-12 Beckman Coulter Ultracentrifuge Support Services Field Service Support......................................................... 5-2 Field Rotor Inspection Program ......................................... 5-2 Rotor Safety Seminars ....................................................... 5-2 On-Site Rotor Inspection and Maintenance ....................... 5-2 A Comprehensive Approach to Centrifuge System Care ..................................................... 5-2 iii www.beckmancoultercentrifugation.com Ultracentrifugation 1 Ultracentrifuge Descriptions Optima X Series Floor Model Preparative ................................. 1-2 Optima MAX Series Tabletop Preparative ................................. 1-4 Airfuge Air-Driven Micro-Ultracentrifuge ................................ 1-6 Instrument Classifications; Speed Reductions; Rotor Designations........................................................................ 1-7 k Factors; Centrifugal Forces ........................................................ 1-7 Tube Kits; Use of Small Tubes; g-Max System ............................ 1-7 Quick-Reference Guide to Instrument Classification Rotor Compatibility ...................................................................... 1-8 Beckman Coulter Floor Model Ultracentrifuge Rotors by Use ........................................................................................... 1-9 Rotors for Floor Model Preparative Ultracentrifuges Fixed-Angle Rotors.................................................................. 1-10 Type 100 Ti ......................................................................... 1-10 Type 90 Ti ........................................................................... 1-11 Type 70.1 Ti ........................................................................ 1-12 Type 70 Ti ............................................................................. 1-13 Type 50.4 Ti ........................................................................ 1-14 Type 50.2 Ti ........................................................................ 1-15 Type 45 Ti ........................................................................... 1-16 Type 42.2 Ti ........................................................................ 1-17 Type 25................................................................................ 1-18 Type 19................................................................................ 1-20 NVT Near-Vertical Tube Rotors .............................................. 1-20 NVT 100 ............................................................................. 1-20 NVT 90 ............................................................................... 1-21 NVT 65.2 ............................................................................ 1-22 NVT 65 ............................................................................... 1-23 Continuous-Flow Rotor CF 32 Ti .............................................................................. 1-36 Zonal Rotors............................................................................. 1-37 Ti-15 .................................................................................... 1-38 Ti-14 .................................................................................... 1-38 Seal Assembly ..................................................................... 1-39 Rotors for Tabletop Ultracentrifuges Quick-Reference Guide to Rotor Specifications and Tabletop Ultracentrifuges Compatibility ............................ 1-40 Fixed-Angle Rotors.................................................................. 1-42 TLA-120.2 .......................................................................... 1-42 TLA-120.1 .......................................................................... 1-43 TLA-110.............................................................................. 1-44 TLA-100.3 .......................................................................... 1-45 TLA-100 ............................................................................. 1-46 TLA-55 ............................................................................... 1-47 MLA-150 ............................................................................ 1-48 MLA-130 ............................................................................ 1-49 MLA-80 .............................................................................. 1-50 MLA-55 .............................................................................. 1-51 MLA-50 .............................................................................. 1-53 NVT Near-Vertical Tube Rotors .............................................. 1-54 TLN-120 ............................................................................. 1-54 TLN-100 ............................................................................. 1-55 MLN-80 .............................................................................. 1-56 Swinging-Bucket Rotors .......................................................... 1-57 TLS-55 ................................................................................ 1-57 MLS-50 ............................................................................... 1-58 Rotors for Airfuge Air-Driven Micro-Ultracentrifuges Vertical-Tube Rotors ................................................................ 1-24 VTi 90 ................................................................................. 1-24 VTi 65.2 .............................................................................. 1-25 VTi 65.1 .............................................................................. 1-26 VTi 50 ................................................................................. 1-27 Fixed-Angle Rotors.................................................................. 1-59 A-110 .................................................................................. 1-59 A-100/30 ............................................................................. 1-59 A-100/18 ............................................................................. 1-60 A-95 .................................................................................... 1-60 Swinging-Bucket Rotors .......................................................... 1-28 SW 60 Ti ............................................................................. 1-28 SW 55 Ti ............................................................................. 1-29 SW 41 Ti ............................................................................. 1-30 SW 40 Ti ............................................................................. 1-31 SW 32.1 Ti .......................................................................... 1-32 SW 32 Ti ............................................................................. 1-33 SW 28.1............................................................................... 1-34 SW 28.................................................................................. 1-35 ACR-90 Chylomicron Rotor .................................................... 1-61 Beckman Coulter Ultracentrifuge Batch Rotor .............................................................................. 1-61 EM-90 Electron Microscopy Particle-Counting Rotor ............ 1-62 1-1 www.beckmancoultercentrifugation.com Ultracentrifugation Optima X Series Floor Model Preparative Ultracentrifuges Experience the visibility and control of our intelligent user interface that makes the Optima X Series a breeze to operate. Our entry-level model, the XE delivers all of the features required to quickly set up and complete a run. Our premium model, the XPN, boasts networking capability and a variety of customizable security and tracking features, ensuring chain of custody and compliance. Both models feature multi-layered BioSafety features in order to maintain a safe working environment. And, as you have come to expect, all instruments are designed as a total system with our innovative rotors and labware. 1 Large touch-screen display Easy to read and navigate. Viewable from across the lab. Intuitive graphical interface with on-screen help. Multilingual software for error-free operation. Remote monitoring and control (XPN only) Saves time. Start, stop, and monitor from computer or smart phone. Receive diagnostic alerts via e-mail. Powerful on-board simulation and calculation tools (XPN only) Saves time and samples. Proprietary software optimizes protocols before running to ensure maximum efficiency. Quickly perform common calculations and conversions. Security and tracking features (XPN only) Manage rotor life by serial number. Track detailed usage history. Password protection and electronic signatures help you maintain chain of custody and compliance. Energy efficient Maintains runs during power fluctuations. Regenerative braking returns energy to local circuit. Highly efficient thermoelectric cooling results in lower power consumption. Quiet-drive technology Designed for lowest drive noise – this is the quietest floor model on the market. Operates at less than 51 dBA. Part Numbers* Model Instrument BioSafe Package** Optima XPN-100 A99846 B10053 Optima XPN-80 A99839 B10051 Optima XPN-90 Optima XE-100 Optima XE-90 A99842 A99836 A99833 B10052 B10050 B10049 * Availability varies by geography. Contact your local sales representative to determine the correct part number for ordering. **BioSafePackageincludescentrifugeandHEPAfilterkit. 1-2 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Ultracentrifugation Features Giant LCD touchscreen display Intuitive, multilingual interface Improved power tolerance Compatible with existing Beckman Coulter rotors Step-by-step zonal/CF operation screens Rotor tracking by serial number User defined programs Remote monitoring and control Password protection and three user access levels Exportable run logs and electronic signatures eXPert simulation software Speed/temperature vs. time plot XE n n n n n XPN n n n n n n n n n n n n 1 Specifications Optima XE Optima XPN Maximum speed (rpm) 100,000 90,000 100,000 90,000 80,000 Maximum RCF (x g) 802,400 694,000 802,400 694,000 548,300 Speed control ± 2 rpm of set speed (above 1,000 rpm) Set temperature 0 to 40°C in 1°C increments Temperature control ± 0.5°C of set temperature∞ Ambient operating range 10 to 35°C Accel / decel profiles 10 accel / 11 decel Braking Operating languages Regenerative, power reclamation English, French, Italian, German, Spanish, Japanese, Russian, Korean, and Chinese (Simplified) Advanced software No User-defined programs No 1,000 with to 30 steps each User profiles No 50 unique users and passwords Electronic signature No Yes Rotor tracking No By serial number Data transfer No (3) USB 2.0 type A connectors, (1) RJ-45 connector Heat output 3400 Btu/hr (1.0 kW) Drive cooling Air-cooled Refrigeration system Thermoelectric - no CFCs, ODCs Sound level Remote control HEPA filter Power requirement Dimensions (H x W x D) Weight Optima eXPert calculations, simulations, references <51 dBA No Available Available 200-240 VAC, 30 A, 50/60 Hz 125.7 x 94 x 68.1 cm 49.5 x 37 x26.8 in 485 kg (1068 lb) ∞ ± 0.8ºC when using SW 32 swinging bucket rotor. Beckman Coulter Ultracentrifuge 1-3 www.beckmancoultercentrifugation.com Ultracentrifugation Optima MAX Series Tabletop Preparative Ultracentrifuge Elevating your laboratory’s potential starts with the optimal tabletop ultracentrifuge. And the Optima MAX Series is the absolute top of the line. Reaching up to 150,000 rpm and over 1,000,000 x g, the Optima MAX instruments set the standard in tabletop speed. Our entry-level model, the MAX-TL, is designed for optimum functionality and efficiency within a compact, quiet package. Our premium model, the Optima MAX-XP, delivers advanced software with password-controlled security features, remote control capability, higher speed, and a wider rotor portfolio. The Optima MAX Series takes sophistication and total system design to a whole new level. 1 Full-color LCD touch-screen display Easy to read and navigate. Intuitive graphical interface with on-screen help. Multilingual software for error-free operation. Remote monitoring and control (Optima MAX-XP Only) Security and tracking features (Optima MAX-XP Only) Saves time. Start, stop, and monitor from your computer. Requires Remote Control Kit (P/N 393395), sold separately. Manage rotor life by serial number. Track detailed usage history. Password protection helps you maintain chain of custody and compliance. Energy efficient The optional HEPA filter combines with innovative Beckman Coulter rotors and labware to offer a multi-layered approach to BioSafety. Trusted by researchers 95% of published protocols citing tabletop or micro-ultracentrifuges reference a Beckman Coulter instrument or rotor. (Source: 2009 Google Scholar search) Part Numbers* Model Optima MAX-XP Optima MAX-TL Instrument 393315 A95761 BioSafe Package** A47882 B11229 Remote Control Package 393395 * Availability varies by geography. Contact your local sales representative to determine the correct part number for ordering. **BioSafePackageincludescentrifugeandHEPAfilterkit. 1-4 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Features Giant LCD touchscreen Intuitive, multilingual interface Numerical vacuum display User-defined programs TL rotor compatibility ML rotor compatibility Password protection and user profiles Exportable run logs Rotor logging by serial number Remote monitoring and control option RPM or RCF user selectable On-screen rotor library MAX-TL n n n n n MAX-XP n n n n n n n n n n n n 1 Specifications MAX-TL MAX-XP Maximum speed (rpm) 120,000 150,000 Maximum RCF (x g) 657,000 Speed control 1,019,000 ± 50 rpm at set speed Set temperature 0 to 40°C in 1°C increments Temperature control ± 2°C of set temperature Ambient operating range 15 to 35°C Accel / decel profiles 10 accel / 11 decel Operating languages English, French, Italian, German, Spanish, Japanese, Russian, Korean, and Chinese (Simplified) User-defined programs Virtually limitless User profiles No Yes Rotor tracking No By serial number Data transfer No Heat output Drive cooling Air-cooled Refrigeration system Solid state - no CFCs, ODCs Sound level Remote control HEPA filter Power requirement Dimensions (H x W x D) Weight Beckman Coulter Ultracentrifuge USB 2.0 type A connectors 2400 Btu/hr (0.7 kW) <47 dBA No Available Available 200-240 VAC, 6 A, 50 Hz 120 VAC, 12 A, 50/60 Hz 100 VAC, 12 A, 50/60 Hz 34.5 (front left) 39.4 (rear right) x 73.9 x 61.7 cm 13.6 (front left) 15.5 (rear right) x 29.1 x 24.3 in 105 kg (230 lb) 1-5 www.beckmancoultercentrifugation.com Ultracentrifugation Airfuge Air-Driven Micro-Ultracentrifuge 1 The unique Airfuge Air-Driven Micro-Ultracentrifuge from Beckman Coulter is a convenient, easy-to-use pelleting tool in research, clinical, and industrial laboratories. Efficient and simple to operate, the Airfuge has a line of general-purpose and special purpose rotors for a wide variety of small-volume applications. The easy-to-operate centrifuge: - Reaches top speed in only 30 seconds - Decelerates smoothly to keep sample contents separated - Offers timed runs of up to five hours with hold position for longer runs - Operates near ambient temperature Airfuge Air-Driven Micro-Ultracentrifuge with digital tachometer. Part Numbers 340400 Airfuge 60 Hz, 120 VAC 340401 50 Hz, 220 VAC 347854 60 Hz, 120 VAC with Digital Tachometer 347855 50 Hz, 220 VAC with Digital Tachometer 1-6 Enhanced versatility with a variety of rotors: - Batch rotor pellets particles from large samples - Chylomicron Rotor achieves rapid clarification of lipemic blood samples - Four fixed angle rotors generate the high speeds and forces necessary to perform a variety of tasks Specifications Maximum Speed 110 000 rpm Maximum g-force (RCF x g) 199 000 x g (A 110 Rotor) Speed Control ± 5 000 rpm of set speed Imbalance Tolerance Up to 10% of volume in opposite tubes Drive Cooling Air-cooled Time Setting 0-300 minutes in five minute increments, HOLD for longer runs Accel/Decel Rates 30-60 seconds/2.5-5.5 minutes Heat Output 0.6 kW/h (1 800 Btu/h) Dimensions 28.0 cm (11 in) W x 38.0 cm (15 in) D x 20.0 cm (8 in) H Weight 10.4 kg (23 lb) Voltage Requirements 60/50 Hz, 100 VAC 50 Hz, 220-240 VAC 60 Hz, 110 VAC Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Ultracentrifugation Instrument Classification Each Beckman Coulter preparative ultracentrifuge carries a safety classification that defines which Beckman Coulter rotors may be safely operated in that centrifuge. The letter classifications (from A to T) take into account rotor energies, size of the rotor chamber, and instrument updates. The classification is indicated on a decal near the rotor chamber or in the About section of the instrument software (depending on the model). If you are unsure of your ultracentrifuge’s correct classification, please call your local Beckman Coulter Service Engineer for assistance. Instruments currently being manufactured are classified as S. Before ordering a rotor, check your instrument’s classification to make certain it will accommodate the rotor selected. Each rotor listing on the following pages indicates the instrument classifications in which they can be used. Beckman Coulter rotors and ultracentrifuges are designed and tested as complete systems, and engineered for safe, reliable operation. We do not test Beckman Coulter rotors in non-Beckman Coulter ultracentrifuges, nor non-Beckman Coulter rotors in Beckman Coulter ultracentrifuges. It is not recommended that Beckman Coulter rotors be used in other instruments or that rotors made by other manufacturers be used in Beckman Coulter ultracentrifuges. Speed Reductions When using any rotor, be sure to observe the instructions given in the appropriate Rotor Manual. Speed limitations lower than those given in this Product Selection Guide may be required because of weight considerations—the weight of a tube, a cap, or the density of the solution being centrifuged. Other considerations, such as the precipitation of cesium salt, require deration of the rotor as well. Use the equations of the CsCl deration curves given in the Rotor Manual to determine the correct rotor speed. If a Rotor Manual has been lost, contact your local Beckman Coulter office to request a replacement. Preparative Floor Model Rotor Designations All fixed-angle preparative floor model ultracentrifuge rotors are designated by the word Type, vertical-tube rotors by the symbol VT, near-vertical by the symbol NVT, and swinging bucket rotors by the symbol SW. The symbol Ti means the rotor is made of titanium. All other rotors are made of aluminum. k Factors The k Factors shown in the rotor charts can be used to compare the efficiency of various rotors for the material that will be centrifuged. They are a guide to the time, t (in hours), required to pellet a particle of known sedimentation coefficient, s (in Svedberg units): t=k/s. Beckman Coulter Ultracentrifuge Centrifugal Forces The centrifugal forces given for rotors in these publications have been rounded to three significant figures using the formula where r is the radius in millimeters. Tube Kits For your ordering convenience, most Beckman Coulter Fixed-Angle Rotors are sold as Rotor Assemblies with a choice of Tube Kits. For rotors that accommodate OptiSeal and Quick-Seal tubes, you can order kits with these tubes instead of a Rotor Package with capped tubes only. Each kit comes complete with up to 200 tubes, the appropriate number of cap assemblies or spacers, Vacuum Grease, and, in the case of the OptiSeal and Quick-Seal Kits, a Tube Rack. For complete ordering information, see the individual rotor listings that follow. Use of Small Tubes With the use of appropriate spacers and/or adapters, many rotors can accommodate tubes smaller than the tube cavities. When centrifuging small samples, use of these smaller tubes increases the efficiency and speeds the process. A chart of compatible tubes is provided with each rotor listing. Innovative g-Max System The g-Max system adds valuable capabilities to your Beckman Coulter ultracentrifuge rotors. Based on a unique approach to tube support within the rotor cavities, the system lets you run smaller volumes in Fixed-Angle, Vertical-Tube and Swinging Bucket Rotors with no reduction in g-force and at lower k Factors to achieve separations in much shorter run times. This system uses patented Beckman Coulter Quick-Seal bell-top tubes and floating spacers. Unlike conventional sleeve-type adapters, the g-Max spacers “float” on top of the tube which keeps the sample at the maximum radius of the tube cavity. Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. To make it easy to order these tubes the first time, g-Max kits are available which include enough spacers to completely fill the rotor, as well as 50 Quick-Seal polyallomer tubes and two tools (one for spacer removal and one for tube removal). These kits are also listed. 1-7 1 www.beckmancoultercentrifugation.com Ultracentrifugation 1 Quick-Reference Guide to Instrument Classification Rotor Compatibility All ultracentrifuges with the following classifications are obsolete and no longer supported with replacement parts or service from Beckman Coulter: A, B, C, D, E. F, G, Q, and some L5/L5B instruments classified as H. The L5B is the newest of these and was last manufactured in 1983. Please contact your Beckman Coulter Sales/Service organization for assistance with any of these models. ‡ 1-8 P/N Rotor 363013 355530 342184 337922 347299 337901 339160 343007 347261 325620 Type 100 Ti Type 90 Ti Type 70.1 Ti Type 70 Ti Type 50.4 Ti Type 50.2 Ti Type 45 Ti Type 42.2 Ti Type 25 Type 19 365898 362752 361073 362755 NVT 100 NVT 90 NVT 65.2 NVT 65 362751 362754 362759 362758 VTi 90 VTi 65.2 VTi 65.1 VTi 50 335649 342194 SW 60 Ti SW 55 Ti 331362 331302 369651 SW 41 Ti SW 40 Ti SW 32.1 Ti 369650 342216 342207 SW 32 Ti SW 28.1 SW 28 350700 CF-32 Ti 969312 Ti-15 Ti-14‡ L7 R • L8/L8M H • • Optima S • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • L/LE R • • • • • • • • • • • • • • Obsolete rotor. Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Beckman Coulter Floor Model Ultracentrifuge Rotors by Use 1 Fastest Rate-Zonal Separation Largest Volume for Pelleting Separation of Virus and Largest Volume Rate-Zonal Separation Viral Particles n n n n n n n n Fastest Separation Separation of Lipoproteins Fastest Differential Flotation n n Largest Volume n Largest Number of Samples n n n n n n n n n n n n n n n n Fastest Separation n n n n n n n n n Largest Volume Beckman Coulter Ultracentrifuge n n n n n n n n n n n n n n n n n n Ti-15 VTi 50 VTi 65.2 VTi 65.1 NVT 65.2 NVT 90 NVT 65 VTi 90 n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n Fastest Separation n n n Fastest Density Gradient Separation Greatest Interband Distance n n n n n n Greatest Interband Space Isopycnic Separation of Plasmid DNA n n n n n n n n Pelleting RNA Through a Largest Volume CsCl Gradient NVT 100 SW 28 n n Largest Number for Differential Flotation Largest Volume for Differential Flotation n n n n Greatest Interband Distance n SW 28.1 n n Fastest Rate-Zonal Separation Rate-Zonal Separation of Proteins in Sucrose Gradient SW 32 Ti SW 32.1 Ti SW 40 Ti SW 41 Ti SW 55 Ti SW 60 Ti n Largest Volume Rate-Zonal Separation CF-32 Ti n Type 19 n Type 25 n Type 45 Ti n Type 42.2 Ti Type 50.2 Ti n Type 50.4 Ti Type 70 Ti Largest Volume for Pelleting Type 70.1 Ti Separation of Subcellular Particles Type 90 Ti Type 100 Ti Floor Model Rotor Selection by Application n n n n n n n n n n n n n n n n n n n n n n n n n 1-9 n www.beckmancoultercentrifugation.com Type 100 Ti Fixed-Angle Rotor, Titanium Type 100 Ti For use in instruments classified: R S Major applications: Rapid separation of plasmid DNA and rapid differential centrifugation of small particles. Axis of Rotation rmin (39.5 mm) rav (55.5 mm) 1 Type 100 Ti 8 x 6.0 mL rmax (71.6 mm) Max. RPM Max. g k Factor 100 000 802 000 15 Number of Tubes Volume/Size Rotor Capacity 8 x 6 mL ⁄2 x 2 1⁄2 in 13 x 64 mm 1 26° 48 mL No. 363013. Type 100 Ti Rotor Assembly with 3 each 876089 O-rings, 3 each 839347 O-rings, and 2 each 363304 Overspeed Disks. No. 363963. Quick-Seal Tube Kit with 4 boxes 344619 Polyallomer Tubes, 8 Spacers 365470, 1 each Tube Removal Tool 361668, Spinkote Lubricant 306812, and Vacuum Grease 335148. (Cordless Tube Topper and Tube Rack required.) Tubes and Bottles Tube Style/Material Quick-Seal Polyallomer Vol. (mL) g-Max Part No. Quantity Size (mm) Required Caps/ Spacers (pkg of 8) Required Adapters (qty. 1) g-Force k Factor 2.0 2.0 3.5 3.5 5.1 5.1 6.0 345829 363962§ 349621 363961§ 362248 363960§ 344619 50 50 50 50 50 50 50 13 x 25 13 x 25 13 x 32 13 x 32 13 x 51 13 x 51 13 x 64 360270 360270 360270 360270 360270 360270 365470 —–— —–— —–— —–— —–— —–— —–— 802 000 802 000 802 000 802 000 802 000 802 000 802 000 7.0 7.0 9.4 9.4 13.5 13.5 15.0 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor, 50 tubes and required tools. Max. Speed 100 000 100 000 100 000 100 000 100 000 100 000 100 000 Rotor Replacement Parts 363037 363039 363304 839347 876089 Rotor Lid Rotor Handle Overspeed Disk, 100 000 rpm O-ring for Rotor Handle O-ring for Rotor Lid Spacers (Package of 8) 365470 fits 13 x 64 mm 360270 fits 13 x 51 mm fits 13 x 32 mm fits 13 x 25 mm Adapters/Spacers/Caps 360270 1-10 365470 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Type 90 Ti Type 90 Ti 8 x 13.5 mL Type 90 Ti Fixed-Angle Rotor, Titanium For use in instruments classified: H R S Major applications: Five-hour separation of plasmid DNA and rapid differential centrifugation of small particles. Axis of Rotation rmin (34.2 mm) rav (55.4 mm) rmax (76.5 mm) Max. RPM Max. g k Factor 90 000 694 000 25 25° No. 355530. Type 90 Ti Rotor Assembly with 3 each 839347 O-rings, 3 each 876089 O-rings, and 2 each 355539 Overspeed Disks. No. 348179. Quick-Seal Tube Kit with 2 boxes 342413 Polyallomer Tubes, 2 boxes 344322 Ultra-Clear Tubes, 12 Spacers 342695, 1 each 348123 Tube Rack, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. (Cordless Tube Topper Kit required; see Tools, Accessories, and Supplies.) Number of Tubes Volume/Size Rotor Capacity 8 x 13.5 mL 5 ⁄8 x 3 in 16 x 76 mm 108 mL No. 348180. Open-Top Tube Kit with 2 boxes 326814 Polyallomer Tubes, 2 boxes 344085 Ultra-Clear Tubes, 12 Tube Caps 341968, 1 Spinkote Lubricant 306812, and 1 Vacuum Grease 335148. (331202 and 305075 Tools required; see Tools, Accessories, and Supplies.) No. 361660. OptiSeal Tube Kit with 4 boxes of OptiSeal Tubes 361623, 12 Spacers 361670 (6 pkg. of 2), 1 OptiSeal Tube Rack 361642, 1 Tube Extraction Tool 361668, and 1 Spacer Removal Tool 338765. Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal Ultra-Clear Polycarbonate Bottle/Assembly Thinwall Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) g-Force 8.9 361623 56 16 x 60 361670§§ —–— 694 000 21 90 000 4.2 4.2 6.3 6.3 10.0 13.5 13.5 356562 357332§ 345830 357334§ 344622 342413 344322 50 50 50 50 50 50 50 16 x 38 16 x 38 16 x 45 16 x 45 16 x 67 16 x 76 16 x 76 345828 345828 345828 345828 344676 342695 342695 —–— —–— —–— —–— —–— —–— —–— 694 000 694 000 694 000 694 000 694 000 694 000 694 000 11 11 14 14 21 25 25 90 000 90 000 90 000 90 000 90 000 90 000 90 000 10.4 10.4 6.5 13.5 4.0 10.0 4.0 10.0 2.0 4.0 6.5 13.5 355603 355651∆∆ 326820 326814 355644 355640 355645 355630 344091 344093 344088 344085 6 25 50 50 25 25 25 25 50 50 50 50 16 x 76 16 x 76 13 x 64 16 x 76 13 x 64 16 x 76 13 x 64 16 x 76 8 x 49 13 x 41 13 x 64 16 x 76 —–— —–— 346256 341968 —–— 338907∆ —–— 338907∆ 303624 346256 346256 341968 —–— —–— 303313 —–— 303313 —–— 303313 —–— 303376 303402 303313 —–— 362 000 362 000 197 000 548 000 197 000 77 000 197 000 197 000 128 000 138 000 197 000 548 000 48 48 69 32 69 190 69 69 72 67 69 32 65 000 65 000 50 000 80 000 50 000∆ 30 000∆ 50 000∆ 50 000∆ 40 000 45 000 50 000 80 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubes and required tools. Set of 2. ∆ M aximumspeedsgivenabovearethosewhichthetubescouldwithstandwhen tested at 25°C for 24 hours. Further tests have shown that the polycarbonate tubes can be run at 75 000 rpm for six hours or at 65 000 rpm for eight hours. ∆∆Bottlesonly. §§ k Factor Max. Speed Rotor Replacement Parts 355528 355529 355530 355539 356959 839347 876089 Lid Rotor Handle Rotor Assembly Overspeed Disk Tool, Handle O Ring, Inner O Ring, Outer Adapters/Spacers/Caps 303313 303376 303402 303624 Beckman Coulter Ultracentrifuge 338907 341968 346256 342695 344676 345828 361670 1-11 1 www.beckmancoultercentrifugation.com Type 70.1 Ti Fixed-Angle Rotor, Titanium Type 70.1 Ti For use in instruments classified: H R S Major applications: Differential centrifugation of subcellular particles. Axis of Rotation rmin (40.5 mm) 1 Type 70.1 Ti 12 x 13.5 mL rav (61.2 mm) rmax (82.0 mm) Max. RPM Max. g k Factor 70 000 450 000 36 Number of Tubes Volume/Size Rotor Capacity 12 x 13.5 mL 5 ⁄8 x 3 in 16 x 76 mm 24° 162 mL No. 348180. Open-Top Tube Kit with 2 boxes 326814 Polyallomer Tubes, 2 boxes 344085 Ultra-Clear Tubes, 12 Tube Caps 341968, 1 Spinkote Lubricant 306812, and 1 Vacuum Grease 335148. (331202 and 305075 Tools required; see Tools, Accessories, and Supplies.) No. 361660. OptiSeal Tube Kit with 4 boxes of OptiSeal Tubes 361623, 12 Spacers 361670 (6 pkg of 2), 1 OptiSeal Tube Rack 361642, 1 Tube Extraction Tool 361668, and 1 Spacer Removal Tool 338765. No. 342184. Type 70.1 Ti Rotor Assembly with 3 each 011757 O-rings, 3 each 858125 O-rings, and 2 each 335585 Overspeed Disks. No. 348179. Quick-Seal Tube Kit with 2 boxes 342413 Polyallomer Tubes, 2 boxes 344322 Ultra-Clear Tubes, 12 Spacers 342695, 1 each 348123 Tube Rack, Spinkote Lubricant 306812, and Vacuum Grease 335148. (Cordless Tube Topper Kit required; see Tools, Accessories, and Supplies.) Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal Ultra-Clear Polycarbonate Bottle Assembly Thinwall Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) g-Force 8.9 361623 56 16 x 60 361670§§ —–— 450 000 32 70 000 4.2 4.2 6.3 6.3 10.0 13.5 13.5 356562 357332§ 345830 357334§ 344622 342413 344322 50 50 50 50 50 50 50 16 x 38 16 x 38 16 x 45 16 x 45 16 x 67 16 x 76 16 x 76 345828 345828 345828 345828 344676 342695 342695 —–— —–— —–— —–— —–— —–— —–— 450 000 450 000 450 000 450 000 450 000 450 000 450 000 17 17 24 24 34 36 36 70 000 70 000 70 000 70 000 70 000 70 000 70 000 10.4 10.4 6.5 13.5 4.0 10.0 4.0 8.0 2.0 4.0 6.5 13.5 355603 355651∆∆ 326820 326814 355644 355640 355645 355630 344091 344093 344088 344085 6 6 50 50 25 25 25 25 50 50 50 50 16 x 76 16 x 76 13 x 64 16 x 76 13 x 64 16 x 76 13 x 64 16 x 76 8 x 49 13 x 41 13 x 64 16 x 76 —–— —–— 346256 341968 —–— 338907∆ —–— 338907∆ 303624 346256 346256 341968 —–— —–— 303313 —–— 303313 —–— 303313 —–— 303376 303402 303313 —–— 388 000 388 000 212 000 450 000 212 000 82 700 212 000 230 000 138 000 152 000 212 000 450 000 42 42 60 36 60 199 60 71 63 58 60 36 65 000 65 000 50 000 70 000 50 000∆ 30 000∆ 50 000∆ 50 000∆ 45 000 45 000 50 000 70 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § Max. Speed Rotor Replacement Parts To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubes and required tools. Set of 2. ∆ M aximumspeedsgivenabovearethosewhichthetubescouldwithstandwhen tested at 25°C for 24 hours. Further tests have shown that the polycarbonate tubes can be run at 75 000 rpm for six hours or at 65 000 rpm for eight hours. ∆∆Bottlesonly. §§ k Factor 011757 335585 337924 342183 858125 O-ring for Rotor Handle Overspeed Disk, 70 000 rpm Rotor Handle Rotor Lid O-ring for Rotor Lid Adapters/Spacers/Caps 303313 1-12 303376 303402 303624 341968 342695 344676 345828 346256 361670 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Type 70 Ti Type 70 Ti 8 x 39 mL Type 70 Ti Fixed-Angle Rotor, Titanium Axis of Rotation For use in instruments classified: H R S Major applications: Differential centrifugation of subcellular fractions. rmin (39.5 mm) rav (65.7 mm) rmax (91.9 mm) Max. RPM Max. g k Factor 70 000 504 000 44 23° No. 337922. Type 70 Ti Rotor Assembly with 3 each 011757 O-rings, 3 each 870612 O-rings, and 2 each 335585 Overspeed Disks. No. 348178. Quick-Seal Tube Kit with 2 boxes 342414 Polyallomer Tubes, 2 boxes 344326 Ultra-Clear Tubes, 12 Spacers 342699, 1 each 348124 Tube Rack, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. (Cordless Tube Topper Kit required; see Tools, Accessories, and Supplies.) Number of Tubes Volume/Size Rotor Capacity 8 x 39 mL 1 x 3 1⁄2 in 25 x 89 mm 312 mL No. 348172. Open-Top Tube Kit with 4 boxes 344367 Polyallomer Tubes, 10 Tube Caps 337927, 1 Spinkote Lubricant 306812, and 1 Vacuum Grease 335148. (338841 and 305075 Tools required; see Tools, Accessories, and Supplies.) No. 361662. OptiSeal Tube Kit with 4 boxes of OptiSeal Tubes 361625, 12 Spacers 361669 (6 pkg of 2), 1 OptiSeal Tube Rack 361646, 1 Tube Extraction Tool 361668, and 1 Spacer Removal Tool 338765. Tubes and Bottles Tube Style/Material Vol. (mL) g-Max Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) g-Force 32.4 15.0 15.0 27.0 27.0 33.0 39.0 15.0 27.0 39.0 26.3 361625 343664 357343§ 343665 357346§ 344623 342414 344324 344323 344326 355618 56 50 50 50 50 50 50 50 50 50 6 25 x 77 25 x 38 25 x 38 25 x 64 25 x 64 25 x 83 25 x 89 25 x 38 25 x 64 25 x 89 25 x 89 361669§§ 343448 343448 343448 343448 344635 342699 343448 343448 342699 —–— —–— —–— —–— —–— —–— —–— —–— —–— —–— —–— —–— 504 000 504 000 504 000 504 000 504 000 504 000 504 000 504 000 504 000 504 000 371 000 44 24 24 31 31 38 44 24 31 44 59 70 000 70 000 70 000 70 000 70 000 70 000 70 000 70 000 70 000 70 000 60 000 6.5 13.5 35.5 38.5 4.0 10.0 30.0 4.0 10.0 30.0 6.5 13.5 38.5 38.5 326820 326814 344367 326823 355644 355640 355642 355645 355630 355631 344088 344085 344058 301112 50 50 50 50 25 25 25 25 25 25 50 50 50 1 13 x 64 16 x 76 25 x 83 25 x 89 13 x 64 16 x 76 25 x 89 13 x 64 16 x 76 25 x 89 13 x 64 16 x 76 25 x 89 25 x 89 346256 330860 337927 331151 —–— 338907† 338906† —–— 338907† 338906† 346256 330860 331151 302133 303392 303307 —–— —–— 303392 303307 —–— 303392 303307 —–— 303392 303307 —–— —–— 102 000 151 000 504 000 371 000 102 000 151 000 371 000 102 000 151 000 371 000 102 000 151 000 371 000 165 000 69 104 43 59 69 104 59 69 104 59 69 104 59 135 45 000 40 000 70 000 60 000 45 000 40 000 60 000 45 000 40 000 60 000 45 000 40 000 60 000 40 000†† OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal Ultra-Clear Polycarbonate Bottle Assembly Thinwall Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Ultra-Clear Stainless Steel k Factor Max. Speed Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubes and required tools. Set of 2. † C apsareoptionalfortheseThickwalltubes.IntheType70Ti,thefillinglevelfor 355642and355631is16.5mL.For355640and355630,thefillinglevelis7.5 mL. Maximum speeds for these open-top tubes without a cap: Polycarbonate—45 000 rpm. Polyallomer—20 000 rpm. These speeds are those which the tubes could withstand when tested at 25°C for 24 hours. Further tests have shown that the polycarbonate tube can run at 50 000 rpm for four hours. †† For solution densities of 2.0 g/mL and below. For solution densities above 2.0 g/ mL, further speed reductions are required. Refer to publication L5-TB-072 when centrifuging stainless steel tubes. §§ Rotor Replacement Parts 011757 335585 337923 337924 870612 O-ring for Rotor Handle Overspeed Disk, 70 000 rpm Rotor Lid Rotor Handle O-ring for Rotor Lid Adapters/Spacers/Caps 303307 303392 330860 331151 Beckman Coulter Ultracentrifuge 337927 338906 338907 342699 343448 344635 346256 361669 302133 1-13 1 www.beckmancoultercentrifugation.com Type 50.4 Ti Type 50.4 Ti Fixed-Angle Rotor, Titanium Axis of Rotation For use in instruments classified: H R S Major applications: Differential flotation of lipoproteins, multisample pelleting, or gradient separations. rmin (80.8 mm) rav (96.1 mm) rmax (111.5 mm) 1 Type 50.4 Ti 44 x 6.5 mL Max. RPM Max. g k Factor 50 000 270 000 312 000 39 33 Number of Tubes Volume/Size 44 x 6.5 mL 1 ⁄2 x 21⁄2 in 13 x 64 mm 20° No. 347299. Type 50.4 Ti Rotor Assembly with 3 each 870138 O-rings, 3 each 854519 O-rings, and 2 each 330336 Overspeed Disks. No. 356957. Quick-Seal Tube Kit with 2 boxes 344619 Polyallomer Tubes, 2 boxes 344320 Ultra-Clear Tubes, 48 Spacers 344389, 1 Tube Rack 348122, 1 Spacer Removal Tool 338765, 1 Spinkote Lubricant 306812, and 1 Vacuum Grease 335148. (Cordless Tube Topper Kit required; see Tools, Accessories, and Supplies.) No. 356956. Open-Top Tube Kit for lipoprotein flotation with 4 boxes 326820 Polyallomer Tubes, 48 Tube Caps with short stems 303113, 1 Spinkote Lubricant 306812, and 1 Vacuum Grease 335148. (301875, 305075, and 841883 Tools required.) Rotor Capacity 286 mL No. 356958. Open-Top Tube Kit with 2 boxes 326820 Polyallomer Tubes, 2 boxes 344088 Ultra-Clear Tubes, 48 Tube Caps with fill holes 346256, 1 Spinkote Lubricant 306812, and 1 Vacuum Grease 335148. (301875, 305075, and 841883 Tools required.) No. 361659. OptiSeal Tube Kit with 4 boxes of OptiSeal Tubes 361621, 8 Spacers 361676 (4 pkg of 2), 1 OptiSeal Tube Rack 361638, 1 Tube Extraction Tool 361668, and 1 Spacer Removal Tool 338765. Tubes and Bottles Tube Style/Material Vol. (mL) g-Max Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) g-Force 4.7 361621 56 13 x 48 361676§§ —–— 312 000 33 50 000 2.0 2.0 6.0 6.0 345829 357329§ 344619 344320 50 50 50 50 13 x 25 13 x 25 13 x 64 13 x 64 345827 345827 344389 344389 —–— —–— —–— —–— 312 000 312 000 312 000 312 000 15 15 33 33 50 000 50 000 50 000 50 000 6.5 326820 50 13 x 64 346256 —–— 312 000 33 50 000 4.0 355644 25 13 x 64 —–— —–— 112 400 91 30 000 1.0 4.0 2.0 6.5 355657 355645 344091 344088 25 25 50 50 8 x 51 13 x 64 8 x 49 13 x 64 —–— —–— 303658 346256 303823 —–— 303823 —–— 252 900 312 000 252 900 312 000 40 33 40 33 45 000 50 000 45 000 50 000 OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal Ultra-Clear Thinwall Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Ultra-Clear Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-Max Kitincludesenoughspacerstofillrotor,50tubes and required tools. §§ Set of 2. k Factor Max. Speed Rotor Replacement Parts 330336 337904 347298 854519 870138 Overspeed Disk, 50 000 rpm Break-away Handle Assembly Rotor Lid O-ring for Rotor Handle O-ring for Rotor Lid Adapters/Spacers/Caps 303113 1-14 303658 303823 344389 345827 346256 361676 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Type 50.2 Ti Type 50.2 Ti 12 x 39 mL Type 50.2 Ti Fixed-Angle Rotor, Titanium Axis of Rotation For use in instruments classified: H R S Note: This rotor cannot be used in 40 000 rpm F or H instruments or the L5-50E unless the instruments have been upgraded with a diffusion pump and vacuum indicator. rmin (54.4 mm) Major applications: Differential centrifugation of subcellular fractions. rav (81.2 mm) rmax (107.9 mm) Max. RPM Max. g k Factor 50 000 302 000 69 Number of Tubes Volume/Size Rotor Capacity 12 x 39 mL 468 mL 1 x 31⁄2 in 24° 25 x 89 mm No. 337901. Type 50.2 Ti Rotor Assembly with 3 each 834301 O-rings, 3 each 854519 O-rings, and 2 each 330336 Overspeed Disks. No. 348178. Quick-Seal Tube Kit with 2 boxes 342414 Polyallomer Tubes, 2 boxes 344326 Ultra-Clear Tubes, 12 Spacers 342699, 1 each 348124 Tube Rack, 306812 Spinkote Lubricant , and 335148 Vacuum Grease. (Cordless Tube Topper Kit required; see Tools, Accessories, and Supplies.) No. 348177. Open-Top Tube Kit with 2 boxes 326823 Polyallomer Tubes, 2 boxes 344058 Ultra-Clear Tubes, 12 Tube Caps 331151, 1 Spinkote Lubricant 306812, and 1 Vacuum Grease 335148. (331202 and 305075 Tools required; see Tools, Accessories, and Supplies.) No. 361662. OptiSeal Tube Kit with 4 boxes of OptiSeal Tubes 361625, 12 Spacers 361669 (6 pkg of 2), 1 OptiSeal Tube Rack 361646, 1 Tube Extraction Tool 361668, and 1 Spacer Removal Tool 338765. Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal Ultra-Clear Bottle Assembly Polycarbonate Thinwall Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Ultra-Clear Stainless Steel Vol. (mL) g-Max Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) g-Force 32.4 361625 56 25 x 77 361669§§ —–— 302 000 69 50 000 15.0 15.0 27.0 27.0 33.0 39.0 15.0 27.0 39.0 26.3 343664 357343§ 343665 357346§ 344623 342414 344324 344323 344326 355618 50 50 50 50 50 50 50 50 50 6 25 x 38 25 x 38 25 x 64 25 x 64 25 x 83 25 x 89 25 x 38 25 x 64 25 x 89 25 x 89 343448 343448 343448 343448 344635 342699 343448 343448 342699 —–— —–— —–— —–— —–— —–— —–— —–— —–— —–— —–— 302 000 302 000 302 000 302 000 302 000 302 000 302 000 302 000 302 000 302 000 39 39 55 55 68 69 39 55 69 69 50 000 50 000 50 000 50 000 50 000 50 000 50 000 50 000 50 000 50 000 6.5 13.5 38.5 4.0 10.0 30.0 4.0 10.0 30.0 6.5 13.5 38.5 38.5 326820 326814 326823 355644 355640† 355642† 355645 355630† 355631† 344088 344085 344058 301112 50 50 50 25 25 25 25 25 25 50 50 50 1 13 x 64 16 x 76 25 x 89 13 x 64 16 x 76 25 x 89 13 x 64 16 x 76 25 x 89 13 x 64 16 x 76 25 x 89 25 x 89 346256 330860 331151 —–— 338907 338906 —–— 338907 338906 346256 330860 331151 302133 303392 303307 —–— 303392 303307 —–— 303392 303307 —–— 303392 303307 —–— —–— 194 000 179 000 302 000 194 000 179 000 302 000 194 000 179 000 302 000 194 000 179 000 302 000 165 000 61 85 69 61 85 69 61 85 69 61 85 69 127 * Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubes and required tools. §§ Set of 2. † C apsareoptionalforthesethickwalltubes.IntheType50.2Ti,thefillinglevel for P/N 355642 and P/N 355631 is 16.5 mL. For P/N 355640 and P/N 355630, thefillinglevelis8mL.Maximumspeedsfortheseopen-toptubeswithoutacap: Polycarbonate — 45 000 rpm; Polyallomer — 20 000 rpm. These speeds are those which the tubes could withstand when tested at 25ºC for 24 hours. Further tests have shown that the polycarbonate tubes can run at 50 000 rpm for four hours. k Factor Max. Speed 43 000 40 000 50 000 43 000 40 000 50 000 43 000 45 000 50 000 43 000 40 000 50 000 37 000†† Rotor Replacement Parts 330336 337903 337904 834301 854519 Overspeed Disk, 50 000 rpm Rotor Lid Break-away Handle Assembly Large O-ring for Rotor Lid Small O-ring for Rotor Lid †† Refer to the section on RUN SPEEDS in the Type 50.2 Rotor manual before using stainless steel tubes. Adapters/Spacers/Caps 303307 303392 330860 331151 Beckman Coulter Ultracentrifuge 338906 338907 342699 343448 344635 346256 361669 302133 1-15 1 www.beckmancoultercentrifugation.com Type 45 Ti Type 45 Ti 6 x 94 mL Type 45 Ti Fixed-Angle Rotor, Titanium Axis of Rotation For use in instruments classified: H R S Note: This rotor cannot be used in 40 000 rpm F or H instruments or the L5-50E unless the instruments have been upgraded with a diffusion pump and vacuum indicator. rmin (35.9 mm) 1 rav (69.8 mm) Major applications: Differential centrifugation of large volumes of subcellular fractions and viruses. rmax (103.8 mm) Max. RPM Max. g k Factor Number of Tubes Volume/Size 45 000 235 000 133 6 x 94 mL 24° Rotor Capacity 564 mL 11⁄2 x 4 in 38 x 102 mm No. 339160. Type 45 Ti Rotor Assembly with 3 each 854519 O-rings, 3 each 878260 O-rings, and 2 each 335458 Overspeed Disks. No. 348175. Quick-Seal Tube Kit with 4 boxes 345776 Polyallomer Tubes, 4 boxes 345778 Ultra-Clear Tubes, 8 Spacers 342697, 1 each 348125 Tube Rack, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. (Cordless Tube Topper Kit required; see Tools, Accessories, and Supplies.) No. 348176. Open-Top Tube Kit with 4 boxes 345775 Polyallomer Tubes, 4 boxes 345777 Ultra-Clear Tubes, 8 Tube Caps 330901, 1 Spinkote Lubricant 306812, and 1 Vacuum Grease 335148. (331202 and 305075 Tools required; see Tools, Accessories, and Supplies.) Tubes and Bottles Tube Style/Material Vol. (mL) Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) g-Force k Factor Quick-Seal Polyallomer Quick-Seal Ultra-Clear Polycarbonate Bottle/Assembly Thinwall Polyallomer 94.0 345776 25 38 x 102 342697 —–— 235 000 133 45 000 94.0 345778 25 38 x 102 342697 —–— 235 000 133 45 000 70.0 70.0 6.5 10.5 13.5 94.0 4.0 10.0 10.0 81.0 4.0 10.0 10.0 81.0 6.5 10.5 13.5 94.0 355655∆∆ 355622§§§ 326820 326822 326814 345775 355644 355640 355639 355643 355645 355630 355629 355628 344088 344087 344085 345777 6 6 50 50 50 25 25 25 25 25 25 25 25 25 50 50 50 25 38 x 102 38 x 102 13 x 64 13 x 89 16 x 76 38 x 102 13 x 64 16 x 76 13 x 89 38 x 102 13 x 64 16 x 76 13 x 89 38 x 102 13 x 64 13 x 89 16 x 76 38 x 102 355623 —–— 346256 346256 330860 330901 —–— 338907† —–— 338905† —–— 338907† —–— 338905† 346256 346256 330860 330901 —–— —–— 303449 303459 303448 —–— 303449 303448 303459 —–— 303449 303448 303459 —–— 303449 303459 303448 —–— 235 000 235 000 138 000 156 000 149 000 235 000 138 000 149 000 156 000 235 000 138 000 149 000 156 000 235 000 138 000 156 000 149 000 235 000 133 133 90 110 107 133 90 107 110 133 90 107 110 133 90 110 107 133 45 000† 45 000† 39 000 39 000 39 000 45 000 39 000 39 000 39 000 45 000 39 000 39 000 39 000 45 000 39 000 39 000 39 000 45 000 Thickwall Polyallomer Thickwall Polycarbonate Ultra-Clear Bottle assembly. Reduce speed to 35 000 rpm when the bottle is centrifuged less thanfull(minimumfillvolumeis35mL). ∆∆Bottleonly.Reducespeedto35000rpmwhenthebottleiscentrifugedlessthan full(minimumfillvolumeis35mL). † CapsareoptionalfortheseThickwalltubes.IntheType45Tithefillinglevelfor 355643and355628is47mL.For355640and355630,thefillinglevelis8mL. Maximum speeds for these open-top tubes without a cap: Polycarbonate — 30 000 rpm; Polyallomer — 15 000 rpm. §§§ Max. Speed Rotor Replacement Parts 335458 339163 339164 854519 878260 Overspeed Disk, 45 000 rpm Rotor Lid Rotor Handle O-ring, small, for Rotor Lid O-ring, large, for Rotor Lid Adapters/Spacers/Caps 303448 303449 303459 1-16 330860 330901 338905 338907 342697 346256 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Type 42.2 Ti Type 42.2 Ti 72 x 230 µL Fixed-Angle Rotor, Titanium For use in instruments classified: H R S Major applications: Differential flotation of lipoproteins, rapid separation of viruses and microsomes. rmeniscus (104 mm) rmax (113 mm) Axis of Rotation 30° Max. RPM Max. g 42 000 223 000 k Factor 9 Number of Tubes Volume/Size 72 x 230 µL 0.29 x 0.8 in 7 x 20 mm Rotor Capacity 16.5 mL No. 343007. Type 42.2 Rotor Package. Includes Rotor, 1 box 342303 Cellulose Propionate Tubes, 3 each 885028 O-rings, 2 each 330329 Overspeed Disks, 1 Vise Assembly 332688, 1 Rotor Handle 343008, 1 Forceps 878446, 1 Spinkote Lubricant 306812, and 1 Vacuum Grease 335148. Tubes and Bottles Tube Style/Material Cellulose Propionate Thickwall Polyallomer Thickwall Polycarbonate Volume (µL) Part No. Quantity Size (mm) Caps/ Spacers (qty. 1) g-Force k Factor Maximum Speed 230 342303 100 7 x 20 —–— 223 000 9 42 000 230 343621 100 7 x 20 —–— 223 000 9 42 000 230 343775 100 7 x 20 —–— 223 000 9 42 000 Note: Originally this rotor was intended for small-sample lipoprotein applications and was called the LP 42 Ti. However, it has become a popular choice for processing a variety of microsamples, and the name has beenchangedtotheType42.2Titoreflectitsmoregeneraluse. Beckman Coulter Ultracentrifuge Rotor Replacement Parts 330329 332688 343008 878446 885028 Overspeed Disk, 42 000 rpm Vise Assembly Rotor Handle Forceps O-ring for Rotor Lid 1-17 1 www.beckmancoultercentrifugation.com Type 25 Type 25 100 x 1 mL Type 25 Fixed-Angle Rotor, Aluminum Axis of Rotation For use in instruments classified: H R S Major applications: Differential flotation of many small samples of lipoproteins. 1 Row 1 Row 2 Row 3 rmax (132.1 mm) rmax (116.3 mm) rmax (100.4 mm) 25° No. 347261. Type 25 Rotor Assembly with 3 each 011757 O-rings, 3 each 878272 O-rings, 2 each 330333 Overspeed Disks. No. 348184. Quick-Seal Tube Kit with 4 boxes 345831 Quick-Seal Polyallomer Tubes, 50 Spacers 345824, 1 Tube Rack 349661, 1 Spinkote Lubricant 306812, and 1 Vacuum Grease 335148. (Cordless Tube Topper Kit required; see Tools, Accessories, and Supplies.) Max. RPM Max. g k Factor 25 000 70 300 81 400 92 500 84 71 62 Number of Tubes Volume/Size Rotor Capacity 100 x 1 mL 5 ⁄16 x 2 in 8 x 51 mm 100 mL No. 348635. Open-Top Tube Kit with 5 boxes 355657 Thickwall Polycarbonate Tubes, 1 Spinkote Lubricant 306812, and 1 Vacuum Grease 335148. Tubes and Bottles Tube Style/Material Thickwall Polycarbonate Quick-Seal Polyallomer Vol. (mL) Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) g-Force k Factor Max. Speed 1.0 355657 25 8 x 51 —–— —–— 92 500 62 25 000 1.0 345831 50 8 x 51 345824 —–— 92 500 62 25 000 Note: Dimensions and forces for the three rows of tubes in the Type 25 rotor are as follows: Row 1 Row 2 Row 3 rmin (mm) force (g) 81.7 57 200 97.5 68 300 113.4 79 400 rav (mm) force (g) 91.1 63 800 106.9 74 800 122.8 86 000 rmax (mm) force (g) 100.4 70 300 116.3 81 400 132.1 92 500 Rotor Replacement Parts 011757 330333 335453 347266 347267 878272 O-ring for Rotor Handle Overspeed Disk, 25 000 rpm Overspeed Disk, 23 000 rpm Rotor Lid Rotor Handle O-ring for Rotor Body Spacers 345824 1-18 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Type 19 Type 19 6 x 250 mL Type 19 Fixed-Angle Rotor, Aluminum For use in instruments classified: H R S Major applications: Differential centrifugation of large volumes of viruses and large subcellular particles. Axis of Rotation rmin (34.4 mm) rav (83.9 mm) rmax (133.4 mm) Max. RPM Max. g k Factor 19 000 53 900 951 Number of Tubes Volume/Size 6 x 250 mL 23⁄8 x 43⁄4 in 60 x 121 mm 25° Rotor Capacity 1500 mL No. 325620. Type 19 Rotor Assembly with 3 each 325623 Gaskets, 3 each 801773 O-rings, and 2 each 330331 Overspeed Disks. No. 325632. Type 19 Rotor Package. Includes Rotor, 6 each 334205 250mL Bottle and Cap Assemblies, 1 each 355627 (pkg of 6) 250mL Bottle, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. Bottles Tube Style/Material Vol. (mL) Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) g-Force k Factor Maximum Speed Bottle Assembly Polyallomer 250.0 250.0 355627◊ 334205 6 1 60 x 121 60 x 121 362246 —–— —–— —–— 53 900 53 900 951 951 19 000 19 000 *◊ Bottle without Cap. Beckman Coulter Ultracentrifuge Rotor Replacement Parts 325623 325624 330331 332826 335353 801773 Gasket for Rotor Handle Rotor Handle Overspeed Disk, 19 000 rpm Rotor Lid Bottle Extractor O-ring for Rotor Body 1-19 1 www.beckmancoultercentrifugation.com NVT 100 NVT 100 8 x 5.1 mL NVT Near-Vertical Tube Rotor, Titanium Axis of Rotation For use in instruments classified: R S rmin (48.3 mm) Note: Non-precipitating solutions up to 1.7 g/mL in density can be run in this rotor without a reduction in rotor speed. For speed reductions for CsCl prescription, refer to rotor manual. rav (57.6 mm) 1 Major applications: Separation of plasmid or mitochondrial DNA in CsCl gradients in 2.5 - 4 h. rmax (67.0 mm) 8° No. 365898. NVT 100 Rotor Package with 12 each 342882 Rotor Plug Gaskets, 1 each 342705 Vise Assembly, 367084 Vise Adapter Assembly, 858121 Torque Wrench, 976959 Torx Wrench Adapter, 306812 Spinkote Lubricant, and 2 each 363304 Overspeed Disks. Max. RPM Max. g k Factor 100 000 750 000 8 Number of Tubes Volume/Size Rotor Capacity 8 x 5.1mL 1 ⁄2 x 2 in 13 x 51 mm 40.8 mL No. 360979. Quick-Seal Tube Kit with 4 boxes 342412 Quick-Seal Polyallomer Tubes, 8 Spacers 342883, 1 Tube Rack 348122, and 1 Tube Extraction Tool 361668 (Cordless Tube Topper Kit required, see Tools, Accessories, and Supplies). Tubes and Bottles Tube Style/Material Quick-Seal Polyallomer Vol. (mL) g-Max Part No. Quantity Size (mm) Spacers (qty. 1) Floating Spacers (qty. 1) g-Force 2.0 2.0 5.1 345829 357325§ 342412 50 50 50 13 x 25 13 x 25 13 x 51 342883 342883 342883 345827 345827 —–— 750 000 750 000 750 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor, 50 tubes and required tools. k Factor 6 6 8 Max. Speed 100 000 100 000 100 000 Rotor Replacement Parts 342882 363304 368545 368546 858121 976959 Gasket for Rotor Plug Overspeed Disk, 100 000 rpm Rotor Replacement Plug (single) Rotor Replacement Plugs with Gaskets (set of 8) Torque Wrench Torx Wrench Adapter Adapters/Spacers 342883 1-20 345827 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com NVT 90 NVT 90 8 x 5.1 mL Type NVT 90 NVT Near-Vertical Tube Rotor, Titanium Axis of Rotation For use in instruments classified: H R S Note: Non-precipitating solutions up to 1.7 g/mL in density can be run in this rotor without a reduction in rotor speed. For speed reductions for CsC1 prescription, refer to rotor manual. rmin (52.4 mm) rav (61.8 mm) rmax (71.1 mm) Major applications: Separation of plasmid or mitochondrial DNA in CsC1 gradients in 2.5 – 4 h. 8° No. 362752. NVT 90 Rotor Package with 12 each 342882 Rotor Plug Gaskets, 1 each 342705 Vise Assembly, 858121 Torque Wrench, 976959 Torx Wrench Adapter, 306812 Spinkote Lubricant, and 2 each 355539 Overspeed Disks. No. 360970. OptiSeal Tube Kit with 4 boxes 362185 OptiSeal Polyallomer Tubes, 8 Spacers 362198, 1 Tube Rack 361638, 1 Tube Extraction Tool 361668, and 1 Spacer Removal Tool 338765. Max. RPM Max. g k Factor 90 000 645 000 10 Number of Tubes Volume/Size Rotor Capacity 8 x 5.1 mL 1 ⁄2 x 2 in 13 x 51 mm 40.8 mL No. 360979. Quick-Seal Tube Kit with 4 boxes 342412 Quick-Seal Polyallomer Tubes, 8 Spacers 342883, 1 Tube Rack 348122, and 1 Tube Extraction Tool 361668 (Cordless Tube Topper Kit required, see Tools, Accessories, and Supplies). Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Spacers (qty. 1) Floating Spacers (qty. 1) g-Force 4.9 362185 56 13 x 51 362198 —–— 645 000 10 90 000 2.0 2.0 5.1 5.1 345829 357325§ 342412 344075 50 50 50 50 13 x 25 13 x 25 13 x 51 13 x 51 342883 342883 342883 342883 345827 345827 —–— —–— 645 000 645 000 645 000 645 000 7 7 10 10 90 000 90 000 90 000 90 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubes, and required tools. k Factor Max. Speed Rotor Replacement Parts 342882 355539 368545 368546 858121 976959 Gasket for Rotor Plug Overspeed Disk, 90 000 rpm Rotor Replacement Plug (single) Rotor Replacement Plugs with Gaskets (set of 8) Torque Wrench Torx Wrench Adapter Adapters/Spacers 342883 345827 362198 Beckman Coulter Ultracentrifuge 1-21 1 www.beckmancoultercentrifugation.com NVT 65.2 NVT Near-Vertical Tube Rotor, Titanium Axis of Rotation For use in instruments classified: H R S Note: Solutions up to 1.7 g/mL in density can be run in this rotor without a reduction in rotor speed. rmin (68.8 mm) 1 NVT 65.2 16 x 5.1 mL Major applications: Separation of plasmid, mitochondrial, or chromosomal DNA, proteoglycans, and lipoproteins. rav (78.4 mm) rmax (87.9 mm) Max. RPM Max. g k Factor 65 000 416 000 15 8.5° No. 361073. NVT 65.2 Rotor Package with 12 each 342882 Rotor Plug Gaskets, 1 each 342705 Vise Assembly, 858121 Torque Wrench, 976959 Torx Wrench Adapter, 306812 Spinkote Lubricant, and 2 each 330338 Overspeed Disks. No. 360972. OptiSeal Tube Kit with 4 boxes 362185 OptiSeal Polyallomer Tubes, 16 Spacers 362198, 1 Tube Rack 361638, 1 Tube Extraction Tool 361668, and 1 Spacer Removal Tool 338765. Number of Tubes Volume/Size Rotor Capacity 16 x 5.1 mL 1 ⁄2 x 2 in 13 x 51 mm 81.6 mL No. 360977. Quick-Seal Tube Kit with 4 boxes 342412 Quick-Seal Polyallomer Tubes, 16 Spacers 342883, 1 Tube Rack 348122, and 1 Tube Extraction Tool 361668 (Cordless Tube Topper Kit required, see Tools, Accessories, and Supplies). Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Spacers (qty. 1) Floating Spacers (qty. 1) g-Force 4.9 362185 56 13 x 51 362198 —–— 416 000 15 65 000 2.0 2.0 5.1 5.1 345829 357326§ 342412 344075 50 50 50 50 13 x 25 13 x 25 13 x 51 13 x 51 342883 342883 342883 342883 345827 345827 —–— —–— 416 000 416 000 416 000 416 000 7 7 15 15 65 000 65 000 65 000 65 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubes and required tools. k Factor Max. Speed Rotor Replacement Parts 330338 342882 368545 368546 858121 976959 Overspeed Disk, 65 000 rpm Gasket for Rotor Plug Rotor Replacement Plug (single) Rotor Replacement Plugs with Gaskets (set of 8) Torque Wrench Torx Wrench Adapter Adapters/Spacers 342883 1-22 345827 362198 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com NVT 65 NVT 65 8 x 13.5 mL Type NVT 65 NVT Near-Vertical Tube Rotor, Titanium Axis of Rotation For use in instruments classified: H R S Note: Non-precipitating solutions up to 1.7 g/mL in density can be run in this rotor without a reduction in rotor speed. rmin (59.5 mm) rav (72.2 mm) rmax (84.9 mm) Major applications: Separation of plasmid or mitochondrial DNA in CsC1 gradients. Max. RPM Max. g k Factor 65 000 402 000 21 7.5° No. 362755. NVT 65 Rotor Package with 12 each 349290 Rotor Plug Gaskets, 1 each 342705 Vise Assembly, 858121 Torque Wrench, 976959 Torx Wrench Adapter, 306812 Spinkote Lubricant, and 2 each 330338 Overspeed Disks. No. 360973. OptiSeal Tube Kit with 4 boxes 362181 OptiSeal Polyallomer Tubes, 8 Spacers 362202, 1 Tube Rack 360538, 1 Tube Extraction Tool 361668, and 1 Spacer Removal Tool 338765. Number of Tubes Volume/Size Rotor Capacity 8 x 13.5 mL 5 ⁄8 x 3 in 16 x 76 mm 108 mL No. 360976. Quick-Seal Tube Kit with 4 boxes 342413 Quick-Seal Polyallomer Tubes, 8 Spacers 349289, 1 Tube Rack 348123, and 1 Tube Extraction Tool 361668 (Cordless Tube Topper Kit required, see Tools, Accessories, and Supplies). Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Spacers (qty. 1) Floating Spacers (qty. 1) g-Force 11.2 362181 56 16 x 70 362202 —–— 402 000 17 65 000 6.3 6.3 8.0 8.0 10.0 13.5 13.5 345830 357335§ 344621 357337§ 344622 342413 344322 50 50 50 50 50 50 50 16 x 45 16 x 45 16 x 58 16 x 58 16 x 67 16 x 76 16 x 76 349289 349289 349289 349289 349289 349289 349289 349900 349900 356571 356571 349901 —–— —–— 402 000 402 000 402 000 402 000 402 000 402 000 402 000 8 8 11 11 15 21 21 65 000 65 000 65 000 65 000 65 000 65 000 65 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubes and required tools. k Factor Max. Speed Rotor Replacement Parts 330338 349290 368545 392084 858121 976959 Overspeed Disk, 65 000 rpm Gasket for Rotor Plug Rotor Replacement Plug (single) Rotor Replacement Plugs with Gaskets (set of 8) Torque Wrench Torx Wrench Adapter Adapters/Spacers 349900 349901 349289 Beckman Coulter Ultracentrifuge 356571 362202 1-23 1 www.beckmancoultercentrifugation.com VTi 90 VTi 90 8 x 5.1 mL VTI-90 Vertical-Tube Rotor, Titanium Axis of Rotation For use in instruments classified: H R S Note: Solutions up to 1.7 g/mL in density can be run in this rotor without reduction in rotor speed. rmin (57.9 mm) rav (64.5 mm) rmax (71.1 mm) 1 Major applications: High-speed density gradient separations. Max. RPM Max. g k Factor 90 000 645 000 6 0° No. 362751. VTi 90 Rotor Package with 12 each 342882 Rotor Plug Gaskets, 1 each 342705 Vise Assembly, 858121 Torque Wrench, 976959 Torx Wrench Adapter, 306812 Spinkote Lubricant, and 2 each 355539 Overspeed Disks. No. 360970. OptiSeal Tube Kit with 4 boxes 362185 OptiSeal Polyallomer Tubes, 8 Spacers 362198, 1 Tube Rack 361638, 1 Tube Extraction Tool 361668, and 1 Spacer Removal Tool 338765. Number of Tubes Volume/Size Rotor Capacity 8 x 5.1 mL 1 ⁄2 x 2 in 13 x 51 mm 40.8 mL No. 360979. Quick-Seal Tube Kit with 4 boxes 342412 Quick-Seal Polyallomer Tubes, 8 Spacers 342883, 1 Tube Rack 348122, and 1 Tube Extraction Tool 361668 (Cordless Tube Topper Kit required, see Tools, Accessories, and Supplies). Tubes and Bottles Tube Style/Material Vol. (mL) g-Max Part No. Quantity Size (mm) Spacers (qty. 1) Floating Spacers (qty. 1) g-Force 4.9 362185 56 13 x 51 362198 ——— 645 000 6 90 000 2.0 2.0 5.1 5.1 357325§ 345829 342412 344075 50 50 50 50 13 x 25 13 x 25 13 x 51 13 x 51 342883 342883 342883 342883 345827 345827 ——— ——— 645 000 645 000 645 000 645 000 6 6 6 6 90 000 90 000 90 000 90 000 OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal Ultra-Clear Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubes and required tools. k Factor Max. Speed Rotor Replacement Parts 342882 355539 368545 368546 858121 976959 Gasket for Rotor Plug Overspeed Disk, 90 000 rpm Rotor Replacement Plug (single) Rotor Replacement Plugs with Gaskets (set of 8) Torque Wrench Torx Wrench Adapter Adapters/Spacers 342883 1-24 345827 362198 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com VTi 65.2 VTi 65.2 16 x 5.1 mL VTI-65.2 Vertical-Tube Rotor, Titanium For use in instruments classified: H R S Axis of Rotation Note: Solutions up to 1.7 g/mL in density can be run in this rotor without reduction in rotor speed. rmin (74.7 mm) rav (81.3 mm) rmax (87.9 mm) Major applications: Isopycnic and rate-zonal centrifugation of small particles. Max. RPM Max. g k Factor 65 000 416 000 10 0° No. 362754. VTi 65.2 Rotor Package with 12 each 342882 Rotor Plug Gaskets, 1 each 342705 Vise Assembly, 858121 Torque Wrench, 976959 Torx Wrench Adapter, 306812 Spinkote Lubricant, and 2 each 330338 Overspeed Disks. No. 360972. OptiSeal Tube Kit with 4 boxes 362185 OptiSeal Polyallomer Tubes, 16 Spacers 362198, 1 Tube Rack 361638, 1 Tube Extraction Tool 361668, and 1 Spacer Removal Tool 338765. Number of Tubes Volume/Size Rotor Capacity 16 x 5.1 mL 1 ⁄2 x 2 in 13 x 51 mm 81.6 mL No. 360977. Quick-Seal Tube Kit with 4 boxes 342412 Quick-Seal Polyallomer Tubes, 16 Spacers 342883, 1 Tube Rack 348122, and 1 Tube Extraction Tool 361668 (Cordless Tube Topper Kit required, see Tools, Accessories, and Supplies). Tubes and Bottles Tube Style/Material Vol. (mL) g-Max Part No. Quantity Size (mm) Spacers (qty. 1) Floating Spacers (qty. 1) g-Force 4.9 362185 56 13 x 51 362198 ——— 416 000 10 65 000 2.0 2.0 5.1 5.1 357326§ 345829 342412 344075 50 50 50 50 13 x 25 13 x 25 13 x 51 13 x 51 342883 342883 342883 342883 345827 345827 ——— ——— 416 000 416 000 416 000 416 000 10 10 10 10 65 000 65 000 65 000 65 000 OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal Ultra-Clear Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubes and required tools. k Factor Max. Speed Rotor Replacement Parts 330338 342882 368545 368546 858121 976959 Overspeed Disk, 65 000 rpm Gasket for Rotor Plug Rotor Replacement Plug (single) Rotor Replacement Plug Plugs with Gaskets (set of 8) Torque Wrench Torx Wrench Adapter Adapters/Spacers 342883 345827 362198 Beckman Coulter Ultracentrifuge 1-25 1 www.beckmancoultercentrifugation.com VTi 65.1 VTi 65.1 8 x 13.5 mL VTI-65.1 Vertical-Tube Rotor, Titanium Axis of Rotation For use in instruments classified: H R S rmin (68.5 mm) rav (76.7 mm) rmax (84.9 mm) 1 Note: Solutions up to 1.7 g/mL in density can be run in this rotor without reduction in rotor speed. Major applications: Isopycnic and rate-zonal centrifugation of small particles. 0° No. 362759. VTi 65.1 Rotor Package with 12 each 349290 Rotor Plug Gaskets, 1 each 342705 Vise Assembly, 858121 Torque Wrench, 976959 Torque Wrench, 306812 Spinkote Lubricant, and 2 each 330338 Overspeed Disks. No. 360973. OptiSeal Tube Kit with 4 boxes 362181 OptiSeal Polyallomer Tubes, 8 Spacers 362202, 1 Tube Rack 360538, 1 Tube Extraction Tool 361668, and 1 Spacer Removal Tool 338765. Max. RPM Max. g k Factor 65 000 402 000 13 Number of Tubes Volume/Size Rotor Capacity 8 x 13.5 mL 5 ⁄8 x 3 in 16 x 76 mm 108 mL No. 360976. Quick-Seal Tube Kit with 4 boxes 342413 Quick-Seal Polyallomer Tubes, 8 Spacers 349289, 1 Tube Rack 348123, and 1 Tube Extraction Tool 361668 (Cordless Tube Topper Kit required, see Tools, Accessories, and Supplies). Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Spacers (qty. 1) Floating Spacers (qty. 1) g-Force 11.2 362181 56 16 x 70 362202 ——— 402 000 13 65 000 6.3 6.3 8.0 8.0 10.0 13.5 13.5 357335§ 345830 344621 357337§ 344622 342413 344322 50 50 50 50 50 50 50 16 x 45 16 x 45 16 x 58 16 x 58 16 x 67 16 x 76 16 x 76 349289 349289 349289 349289 349289 349289 349289 349900 349900 356571 356571 349901 ——— ——— 402 000 402 000 402 000 402 000 402 000 402 000 402 000 13 13 13 13 13 13 13 65 000 65 000 65 000 65 000 65 000 65 000 65 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubes and required tools. k Factor Max. Speed Rotor Replacement Parts 330338 349290 392083 392084 858121 976959 Overspeed Disk, 65 000 rpm Gasket for Rotor Plug Rotor Replacement Plug (single) Rotor Plugs with Gaskets, Torx (set of 8) Torque Wrench Wrench Adapter for Torx Plug Adapters/Spacers 349900 1-26 349901 349289 356571 362202 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com VTi 50 VTi 50 8 x 39 mL VTI-50 Vertical-Tube Rotor, Titanium Axis of Rotation For use in instruments classified: H R S rmin (60.8 mm) rav (73.7 mm) rmax (86.6 mm) Note: Solutions up to 1.7 g/mL in density can be run in this rotor without reduction in rotor speed. Major applications: Isopycnic and rate-zonal centrifugation. 0° No. 362758. VTi 50 Rotor Package with 12 each 340825 Rotor Plug Gaskets, 1 each 332688 Vise Assembly, 369791 Torque Wrench, 355588 Hex Plug Adapter, 306812 Spinkote Lubricant, and 2 each 330336 Overspeed Disks. No. 360974. OptiSeal Tube Kit with 4 boxes 362183 OptiSeal Polyallomer Tubes, 10 Spacers 362204, 1 Tube Rack 360542, and 1 Tube Extraction Tool 361668. Max. RPM Max. g k Factor 50 000 242 000 36 Number of Tubes Volume/Size Rotor Capacity 8 x 39 mL 1 x 31⁄2 in 25 x 89 mm 312 mL No. 360975. Quick-Seal Tube Kit with 4 boxes 342414 Quick-Seal Polyallomer Tubes, 10 Spacers 342417, 1 Tube Rack 348124, and 1 Tube Extraction Tool 361668 (Cordless Tube Topper Kit required, see Tools, Accessories, and Supplies). Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Spacers (qty. 1) Floating Spacers (qty. 1) g-Force 36.2 362183 56 25 x 87 362204 ——— 242 000 36 50 000 15.0 15.0 27.0 39.0 15.0 27.0 39.0 357344§ 343664 343665 342414 344324 344323 344326 50 50 50 50 50 50 50 25 x 38 25 x 38 25 x 64 25 x 89 25 x 38 25 x 64 25 x 89 342417 342417 342417 342417 342417 342417 342417 343448 343448◊◊ 343448 ——— 343448◊◊ 343448 ——— 242 000 242 000 242 000 242 000 36 36 36 36 50 000 50 000 50 000 50 000 242 000 242 000 242 000 36 36 36 50 000 50 000 50 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubes and required tools. ◊◊ Two required. k Factor Max. Speed Rotor Replacement Parts 330336 Overspeed Disk, 50 000 rpm 340825 Gasket for Rotor Plug 355587 Rotor Plug, Hex Style (If replacing all rotor plugs, use Hex Style) 355588 Hex Plug-wrench Adapter 369791 Torque Wrench Adapters/Spacers 342417 343448 Beckman Coulter Ultracentrifuge 362204 1-27 1 www.beckmancoultercentrifugation.com SW 60 Ti SW 60 Ti Swinging-Bucket Rotor, Titanium Head, and Buckets Axis of Rotation For use in instruments classified: H R S Major applications: Rate-zonal centrifugation of proteins and RNA, differential centrifugation of subcellular fractions. rmax (120.3 mm) rav (91.7 mm) rmin (63.1 mm) 1 SW 60 Ti 6 x 4 mL Max. RPM Max. g k Factor 60 000 485 000 45 90° Number of Tubes Volume/Size Rotor Capacity 6 x 4 mL 7 ⁄16 x 23⁄8 in 11 x 60 mm 24 mL No. 335650. SW 60 Ti Rotor Package. Includes Rotor, 2 boxes 328874 Polyallomer Tubes, 2 boxes 344062 Ultra-Clear Tubes, 1 each 331313 Bucket Holder Rack, 306812 Spinkote Lubricant, 335148 Vacuum Grease, 331155 Overspeed Disk, and 24 each 868638 O-rings. No. 335649. SW 60 Ti Rotor Assembly. Tubes and Bottles Tube Style/Material Quick-Seal Polyallomer Quick-Seal konical Polyallomer Thinwall Polyallomer Thinwall konical Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Floating Spacers (qty. 1) Adapters (qty. 6) g-Force 1.5 1.5 2.0 2.0 1.3 3.0 344624 357323§ 344625 357324§ 358655 358648 50 50 50 50 50 50 11 x 25 11 x 25 11 x 32 11 x 32 11 x 35 11 x 60 344674 344674 344674 344674 344674 344674 ——— ——— ——— ——— 358152 358152 485 000 485 000 485 000 485 000 480 000 480 000 24 24 29 29 31 45 60 000 60 000 60 000 60 000 60 000 60 000 4.0 1.5 3.0 3.0 328874 358117 358118 355636 50 50 50 25 11 x 60 11 x 35 11 x 60 11 x 60 ——— ——— ——— ——— ——— 358152 358152 ——— 485 000 480 000 480 000 485 000 45 31 45 45 60 000 60 000 60 000 60 000 3.0 355635 25 11 x 60 ——— ——— 485 000 45 60 000 4.0 344062 50 11 x 60 ——— ——— 485 000 45 60 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubes and required tools. k Factor Max. Speed Rotor Replacement Parts 331155 331313 332400 335645 337943 Overspeed Disk, 60 000 rpm Bucket Holder Rack Rotor Stand Bucket Cap (each) Bucket Assembly, Titanium, with Caps and O-rings, matched set of 6 868638 O-ring for Bucket Adapters/Spacers 344674 1-28 358152 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com SW 55 Ti SW 55 Ti 6 x 5 mL SW 50 Ti Swinging-Bucket Rotor, Titanium Head, and Buckets (red buckets) Axis of Rotation For use in instruments classified: H R S Major applications: Rate-zonal separations of small particles. rmax (108.5 mm) rav (84.6 mm) rmin (60.8 mm) No. 342196. SW 55 Ti Rotor Package. Includes Rotor, 2 boxes 326819 Polyallomer Tubes, 2 boxes 344057 Ultra-Clear Tubes, 1 each 330070 Hinge Pin Tool, 331313 Bucket Holder Rack, 306812 Spinkote Lubricant, 335148 Vacuum Grease, 328896 Overspeed Disk, and 24 each 824412 O-rings. No. 342194. SW 55 Ti Rotor Assembly. Max. RPM Max. g k Factor 55 000 368 000 48 Number of Tubes Volume/Size Rotor Capacity 6 x 5 mL 1 ⁄2 x 2 in 13 x 51 mm 30 mL No. 361661. OptiSeal Tube Kit with 4 boxes 361627 OptiSeal Polyallomer Tubes, 6 Spacers 361678 (3 pkg of 2), 1 OptiSeal Tube Rack 361650, and 1 Tube Extraction Tool 361668. Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal konical Polyallomer Thinwall Polyallomer Thinwall konical Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Floating Spacers (qty. 1) Adapters (qty. 6) g-Force 3.3 361627 56 2.0 2.0 3.2 345829 357327§ 358647 5.0 3.0 13 x 33 361678§§ ——— 368 000 48 55 000 50 50 50 13 x 25 13 x 25 13 x 51 355535 355535 355535 ——— ——— 358153 368 000 368 000 368 000 29 29 48 55 000 55 000 55 000 326819 358119 50 50 13 x 51 13 x 51 ——— ——— ——— 358153 368 000 368 000 48 48 55 000 55 000 3.5 349623 25 13 x 51 ——— ——— 368 000 48 55 000 3.5 349622 25 13 x 51 ——— ——— 368 000 48 55 000 0.8 5.0 344090 344057 50 50 5 x 41 13 x 51 ——— ——— 356860* ——— 269 000 368 000 64 48 48 000 55 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubes, and required tools. §§ Set of 2. * Adapter 305527 can be used for speed up to 25 000 rpm, set of 1. k Factor Max. Speed Rotor Replacement Parts 328896 331313 332400 342190 342199 Overspeed Disk, 55 000 rpm Bucket Holder Rack Rotor Stand Bucket Cap (each) Bucket Assembly, Titanium, with Caps and O-rings, matched set of 6 824412 O-ring for Bucket Adapters/Spacers 355535 356860 358153 Beckman Coulter Ultracentrifuge 361678 1-29 1 www.beckmancoultercentrifugation.com SW 41 Ti Swinging-Bucket Rotor, Titanium Head, and Buckets (black buckets) Axis of Rotation 1 SW 41 Ti 6 x 13.2 mL SW 41 Ti rmax (153.1 mm) For use in instruments classified: H R S Major applications: Rate-zonal and isopycnic centrifugation of viruses, rate-zonal centrifugation of RNA. rav (110.2 mm) Max. RPM Max. g k Factor 41 000 288 000 124 rmin (67.4 mm) Number of Tubes Volume/Size Rotor Capacity 6 x 13.2 mL 9 ⁄16 x 31⁄2 in 14 x 89 mm 79.2 mL No. 331336. SW 41 Ti Rotor Package. Includes Rotor, 2 boxes 331372 Polyallomer Tubes, 2 boxes 344059 Ultra-Clear Tubes, 1 each 330070 Hinge Pin Tool, 331313 Bucket Holder Rack, 306812 Spinkote Lubricant, 335148 Vacuum Grease, 330335 Overspeed Disk, and 24 each 331309 Gaskets for Buckets. No. 331362. SW 41 Ti Rotor Assembly. Tubes and Bottles Tube Style/Material Quick-Seal Polyallomer Quick-Seal konical Polyallomer Thinwall Polyallomer Thinwall konical Polyallomer Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Floating Spacers (qty. 1) 3.5 5.9 4.0 8.0 13.2 10.0 355870 355537 358650 358649 331372 358120 50 50 50 50 50 50 14 x 25 14 x 47 14 x 48 14 x 89 14 x 89 14 x 89 355534 355534 355534 355534 ——— ——— 13.2 344059 50 14 x 89 ——— Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. * RecommendP/N354468ExtractorTool(konicaltubeadapters). Adapters (qty. 6) g-Force k Factor Max. Speed ——— ——— 358154* 358154* ——— 358154* 288 000 288 000 288 000 288 000 288 000 284 000 27 55 57 124 124 124 41 000 41 000 41 000 41 000 41 000 41 000 ——— 288 000 124 41 000 Rotor Replacement Parts 330335 331309 331763 331313 332400 333790 Overspeed Disk, 41 000 rpm Gasket for Bucket Caps, matched set of 6 Bucket Holder Rack Rotor Stand Bucket Assembly, Black Titanium, with Caps and Gaskets, matched set of 6 Adapters/Spacers 355534 1-30 358154 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com SW 40 Ti SW 40 Ti 6 x 14 mL SW 40 Ti Swinging-Bucket Rotor, Titanium Head, and Buckets (red buckets) Axis of Rotation rmax (158.8 mm) For use in instruments classified: H R S Major applications: Rate-zonal centrifugation of proteins, RNA and subcellular particles. rav (112.7 mm) Max. RPM Max. g k Factor 40 000 285 000 137 rmin (66.7 mm) Number of Tubes Volume/Size Rotor Capacity 6 x 14 mL 9 ⁄16 x 33⁄4 in 14 x 95 mm 84 mL No. 331301. SW 40 Ti Rotor Package. Includes Rotor, 2 boxes 331374 Polyallomer Tubes, 2 boxes 344060 Ultra-Clear Tubes, 1 each 330070 Hinge Pin Tool, 331313 Bucket Holder Rack, 306812 Spinkote Lubricant, 335148 Vacuum Grease, 330335 Overspeed Disk, and 24 each 331309 Gaskets for Buckets. No. 331302. SW 40 Ti Rotor Assembly. Tubes and Bottles Tube Style/Material Quick-Seal Polyallomer Quick-Seal konical Polyallomer Thinwall Polyallomer Thinwall konical Polyallomer Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Floating Spacers (qty. 1) 3.5 5.9 4.0 8.0 355870 355537 358650 358649 50 50 50 50 14 x 25 14 x 47 14 x 48 14 x 89 355534 355534 355534 355534 14.0 10.0 11.0 14.0 331374 358120 358121 344060 50 50 50 50 14 x 95 14 x 89 14 x 95 14 x 95 ——— ——— ——— ——— Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. * RecommendP/N354468ExtractorTool(konicaltubeadapters). Adapters (qty. 6) g-Force k Factor Max. Speed ——— ——— 358154* 358154* 285 000 285 000 285 000 285 000 35 61 57 130 40 000 40 000 40 000 40 000 ——— 358154* 358154* ——— 285 000 285 000 285 000 285 000 137 124 137 137 40 000 40 000 40 000 40 000 Rotor Replacement Parts 330335 331309 331313 331763 332400 333789 Overspeed Disk, 40 000 rpm Gasket for Bucket Bucket Holder Rack Caps, matched set of 6 Rotor Stand Bucket Assembly, Red Titanium, with Caps and Gaskets, matched set of 6 Adapters/Spacers 355534 358154 Beckman Coulter Ultracentrifuge 1-31 1 www.beckmancoultercentrifugation.com SW 32.1 Ti SW 32.1 Ti 6 x 17 mL Swinging-Bucket Rotor and Buckets, Titanium For use in instruments classified: H R S Major applications: Separation of subcellular particles and viruses in density gradients. 1 rmin (64.4 mm) rav rmax (113.6 mm) Max. RPM Max. g k Factor 32 000 187 000 228 Number of Tubes Volume/Size Rotor Capacity 6 x 17 mL 5 ⁄8 x 4 in 16 x 102 mm (162.8 mm) 102 mL Axis of Rotation No. 369696. SW 32.1 Ti Rotor Package. Includes Rotor, 2 boxes 337986 Polyallomer Tubes, 2 boxes 344061 Ultra-Clear Tubes, 1 each 331186 Bucket Holder Rack, 306812 Spinkote Lubricant, 335148 Vacuum Grease, 335456 Overspeed Disk, 978354 hooked O-ring Removal Tool, and 24 each 812715 O-rings. No. 369651. SW 32.1 Ti Rotor Assembly. Tubes and Bottles Tube Style/Material Quick-Seal Polyallomer Quick-Seal konical Polyallomer Thinwall Polyallomer Thinwall konical Polyallomer Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Floating Spacers (qty. 1) Adapters (qty. 6) g-Force k Factor 4.2 6.3 8.0 10.0 18.0 12.5 356562 345830 344621 344622 356291 358653 50 50 50 50 50 50 16 x 38 16 x 45 16 x 58 16 x 67 16 x 102 16 x 102 355579 355579 355579 355579 355579 355579 ——— ——— ——— ——— ——— 358155 187 000 187 000 187 000 187 000 187 000 187 000 56 79 102 133 199 205 32 000 32 000 32 000 32 000 32 000 32 000 17.0 337986 50 16 x 102 ——— ——— 187 000 228 32 000 14.5 17.0 358123 344061 50 50 16 x 102 16 x 102 ——— ——— 358155 ——— 187 000 187 000 225 228 32 000 32 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. Max. Speed Rotor Replacement Parts 331186 332400 335456 369645 369693 812715 Bucket Holder Rack Rotor Stand Overspeed Disk, 32 000 rpm Bucket Cap (each) Bucket Assembly, with Caps and O-rings, set of 6 O-ring for Bucket Extra Buckets for the SW 32.1 Ti The buckets of the SW 32 can be used with the SW 32.1 rotor head. 369692 Bucket Assembly, with Caps and O-rings, set of 6 Adapters/Spacers 355579 1-32 358155 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com SW 32 Ti SW 32 Ti 6 x 38.5 mL Swinging-Bucket Rotor and Buckets, Titanium For use in instruments classified: H R S Major applications: Separation of subcellular particles and viruses in density gradients. Max. RPM Max. g k Factor Number of Tubes Volume/Size 32 000 175 000 204 6 x 38.5 mL 1 x 3.5 in 25 x 89 mm rmin (66.8 mm) rav (109.7 mm) rmax (152.5 mm) Rotor Capacity 231 mL Axis of Rotation No. 369694. SW 32 Ti Rotor Package. Includes Rotor, 1 box 326823 Polyallomer Tubes, 2 boxes 344058 Ultra-Clear Tubes, 1 box 355631 Polycarbonate Tubes, 1 each 331186 Bucket Holder Rack, 306812 Spinkote Lubricant, 335148 Vacuum Grease, 335456 Overspeed Disk, 978354 hooked O-ring Removal Tool, and 24 each 812715 O-rings. No. 369650. SW 32 Ti Rotor Assembly. Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Bell-Top Quick-Seal konical Polyallomer Bell-Top Thinwall konical Polyallomer Thickwall Polyallomer Thinwall Polyallomer Thickwall Polycarbonate Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Floating Spacers (qty. 1) Adapters (qty. 6) g-Force k Factor 32.4 15.0 27.0 33.5 8.4 22.5 28.0 361625 343664 343665 344623 358652 358654 358651 56 50 50 50 50 50 50 25.5 31.5 31.0 358125 358126 355642 38.5 25 x 77 25 x 38 25 x 64 25 x 83 25 x 38 25 x 76 25 x 83 392833§§ 355536 355536 355536 355536 355536 355536 —–— ——— ——— ——— 358156 358156 358156 175 000 175 000 175 000 175 000 175 000 175 000 175 000 155 81 146 192 74 155 198 32 000 32 000 32 000 32 000 32 000 32 000 32 000 50 50 25 25 x 76 25 x 89 25 x 89 ——— ——— ——— 358156 358156 ——— 175 000 175 000 175 000 156 156 198 32 000 32 000 32 000 326823 50 25 x 89 ——— ——— 175 000 204 32 000 31.0 355631 25 25 x 89 ——— ——— 175 000 202 32 000 38.5 344058 50 25 x 89 ——— ——— 175 000 204 32 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. *§§ Set of 2. Max. Speed Rotor Replacement Parts 331186 332400 335456 369643 369692 812715 Bucket Holder Rack Rotor Stand Overspeed Disk, 32 000 rpm Bucket Cap (each) Bucket Assembly, with Caps and O-rings, set of 6 O-ring for Bucket Extra Buckets for the SW 32 Ti The buckets of the SW 32.1 can be used with the SW 32 rotor head. 369693 Bucket Assembly, with Caps and O-rings, set of 6 Adapters/Spacers 355536 358156 392833 Beckman Coulter Ultracentrifuge 1-33 1 www.beckmancoultercentrifugation.com SW 28.1 SW 28.1 6 x 18 mL SW 28.1 Swinging-Bucket Rotor, Aluminum Head, and Titanium Buckets Axis of Rotation For use in instruments classified: H R S Note: Zonal support band (if installed in centrifuge) must be removed before operating this rotor. 1 Major applications: Rate-zonal centrifugation of subcellular particles and viruses, rate-zonal centrifugation of subcellular fractions. rmax (171.3 mm) rav (122.1 mm) rmin (72.9 mm) Max. RPM Max. g k Factor 28 000 150 000 276 Number of Tubes Volume/Size Rotor Capacity 6 x 17 mL 5 ⁄8 x 4 in 16 x 102 mm 102 mL No. 342214. SW 28.1 Rotor Package. Includes Rotor, 2 boxes 337986 Polyallomer Tubes, 2 boxes 344061 Ultra-Clear Tubes, 1 each 331186 Bucket Holder Rack, 306812 Spinkote Lubricant, 335148 Vacuum Grease, 342211 Overspeed Disk, and 24 each 815472 O-rings. No. 342216. SW 28.1 Rotor Assembly. Tubes and Bottles Tube Style/Material Quick-Seal Polyallomer Quick-Seal konical Polyallomer Thinwall Polyallomer Thinwall konical Polyallomer Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Floating Spacers (qty. 1) Adapters (qty. 6) g-Force k Factor 4.2 6.3 8.0 10.0 18.0 12.5 356562 345830 344621 344622 356291 358653 50 50 50 50 50 50 16 x 38 16 x 45 16 x 58 16 x 67 16 x 102 16 x 102 355579 355579 355579 355579 355579 355579 ——— ——— ——— ——— ——— 358155 150 000 150 000 150 000 150 000 150 000 148 000 67 99 134 160 276 276 28 000 28 000 28 000 28 000 28 000 28 000 17.0 14.5 337986 358123 50 50 16 x 102 16 x 102 ——— ——— ——— 358155 150 000 148 000 276 276 28 000 28 000 17.0 344061 50 16 x 102 ——— ——— 150 000 276 28 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. Max. Speed Rotor Replacement Parts 331186 332400 342180 342211 342212 Bucket Holder Rack Rotor Stand Bucket Cap (each) Overspeed Disk, 28 000 rpm Bucket Assembly,Titanium, with Caps and O-rings, matched set of 6 815472 O-ring for Bucket Extra Buckets for the SW 28.1 The large-volume buckets of the SW 28 can be used with the SW 28.1 rotor head. 342217 Bucket Assembly SW 28, Titanium, with Caps and O-rings, matched set of 6 Adapters/Spacers 355579 1-34 358155 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com SW 28 SW 28 6 x 38.5 mL SW 28 Swinging-Bucket Rotor, Aluminum Head, and Titanium Buckets Axis of Rotation For use in instruments classified: H R S Major applications: Differential centrifugation of subcellular fractions and viruses. rmax (161.0 mm) rav (118.2 mm) rmin (75.3 mm) Max. RPM Max. g k Factor 28 000 141 000 246 Number of Tubes Volume/Size Rotor Capacity 6 x 38.5 mL 1 x 31⁄2 in 25 x 89 mm 231 mL No. 342204. SW 28 Rotor Package. Includes Rotor, 2 boxes 326823 Polyallomer Tubes, 2 boxes 344058 Ultra-Clear Tubes,1 each 331186 Bucket Holder Rack, 306812 Spinkote Lubricant, 335148 Vacuum Grease, 342211 Overspeed Disk, and 24 each 812715 O-rings. No. 342207. SW 28 Rotor Assembly. Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Bell-Top Quick-Seal konical Polyallomer Bell-Top Thinwall konical Polyallomer Thickwall Polyallomer Thinwall Polyallomer Thickwall Polycarbonate Ultra-Clear Vol. (mL) g-Max Part No. Quantity Size (mm) Floating Spacers (qty. 1) Adapters (qty. 6) g-Force k Factor 32.4 15.0 27.0 33.5 8.4 22.5 28.0 361625 343664 343665 344623 358652 358654 358651 56 50 50 50 50 50 50 25.5 31.5 31.0 358125 358126 355642 38.5 25 x 77 25 x 38 25 x 64 25 x 83 25 x 38 25 x 76 25 x 83 392833§§ 355536 355536 355536 355536 355536 355536 —–— ——— ——— ——— 358156 358156 358156 141 000 141 000 141 000 141 000 141 000 141 000 141 000 206 87 164 234 87 206 234 28 000 28 000 28 000 28 000 28 000 28 000 28 000 50 50 25 25 x 76 25 x 89 25 x 89 ——— ——— ——— 358156 358156 ——— 141 000 141 000 141 000 206 246 246 28 000 28 000 28 000 326823 50 25 x 89 ——— ——— 141 000 246 28 000 31.0 355631 25 25 x 89 ——— ——— 141 000 246 28 000 38.5 344058 50 25 x 89 ——— ——— 141 000 246 28 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. §§ Set of 2. Max. Speed Rotor Replacement Parts 331186 332400 342179 342211 342217 Bucket Holder Rack Rotor Stand Bucket Cap (each) Overspeed Disk, 28 000 rpm Bucket Assembly, Titanium, with Caps and O-rings, matched set of 6 812715 O-ring for Bucket Extra Buckets for the SW 28 The long slender buckets of the SW 28.1 can be used with the SW 28 rotor head. 342212 Bucket Assembly SW 28.1, Titanium, with Caps and O-rings, matched set of 6 Adapters/Spacers 355536 358156 392833 Beckman Coulter Ultracentrifuge 1-35 1 www.beckmancoultercentrifugation.com CF-32 Ti CF-32 Ti 430 mL Continuous Flow Rotor, Titanium For use in instruments classified: H S Major applications: Isopycnic banding of viruses. 1 Max. RPM Max. g k Factor Rotor Capacity 32 000 102 000 42 430 mL CF-32 Ti Rotor Kit No. 350700 Basic Rotor Kit. Use with Optima X and L Series No. 350867 CF-32 Rotor (Rotor, Lid, O-ring) CF-32 Ti Rotor Packages (for field installation of Optima X and L Series instruments) Includes: Basic Rotor Kit, Door Kit, Adapter Bowl Assembly, and Vacuum Pump. A19656 CF-32 Rotor Package for Optima L Series, 60 Hz A19655 CF-32 Rotor Package for Optima L Series, 50 Hz B10406 CF-32 Rotor Package for Optima X Series, 60 Hz B10463 CF-32 Rotor Package for Optima X Series, 50 Hz CF-32 Ti Accessories 354474 Door Kit and Hardware for Optima L/XL Series A95570 Door Kit and Hardware for Optima X Series B10464 Adapter Bowl Kit for Optima X and L Series 358922 CF-32 Aspirator Vacuum Pump, 120 V 358923 CF-32 Aspirator Vacuum Pump, 220 V 961778 Vibration Mount, Optima (each; 3 needed) 355911 Vibration Mount, L/L2/L3/L5/L8 (set of 3) 354192 Standoff, CF-32 (sold in quantity of 1) Note: A continuous-output gradient pump able to operate against a backpressure of 20 psi (138 kPa) is also required. The purchased pump must be able to provide a flow of up to 150 mL/min. (9 L/hr) and the pump head must accept 1/8-in. (3-mm) I.D. tubing. We recommend a Masterflex pump that can be purchased directly from the manufacturer: www.masterflex.com Rotor Replacement Parts 011167 303636 328946 328949 335222 335303 335456 885203 354680 807446 841687 O-ring for Stem Assembly Backup Washer (red fiber) Gasket for Rotor Lid Non-extrusion Ring Vane for Core Core Handle Overspeed Disk, 32 000 rpm Adapter Bowl O-ring Septa Assembly Fitting, Stainless Steel Small O-ring in Stem Assembly Seal Assembly Replacement Parts 008025 010177 011920 010426 020198 335233 354460 354458 853156 870030 870315 354307 335233 Flat Gasket 335296 Collar 335224 Manifold 870030 Spring 011920 O-ring 010177 O-ring 354460 Static Seal Assembly 885203 O-ring Adapter Bowl and Door 358921 Adapter Bowl Optima/L8 853156 O-ring 335292 Water Jacket Rotor Lid 810651 O-ring 812715 O-ring 354458 Rotating Seal 008025 O-ring 011920 O-ring 010426 O-ring Bearing Assembly††† Transfer Tube††† 335226 Bearing Housing 020198 O-ring 354680 Septa Assembly 335222 Vane 841687 O-ring 335309 Stem Holder Assembly††† O-ring under Rotating Seal (large) O-ring in Static Seal Assembly (medium) O-ring in Static Seal Assembly (small) O-ring in Rotating Seal (small) O-ring in Bearing Base 807446 Fitting Adapter Bowl Flat Gasket/Pad 303636 Washer Static Seal Assembly 011167 O-ring Rotating Seal O-ring in Static Seal Assembly (large) Spring in Manifold O-ring in Manifold CF-32 Stem Assembly/Bearing Kit: Includes a matched and serialized set of Stem Holder Assembly and Bearing Assembly. 328949 Nonextrusion Ring 328946 Gasket 812715 O-ring Rotor Bowl Note: The CF-32 Ti Rotor cannot be used in Beckman Coulter ultracentrifuges thathavebeenmodifiedwiththePrepUV-ScannerorSchlierenaccessories. ††† Available only as part of Stem Assembly/Bearing Kit, P/N 354307. 1-36 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Ti-15 Ti-15 1675 mL Zonal Rotor, Titanium For use in instruments classified: H S Major applications: Rate-zonal centrifugation of subcellular particles. Max. RPM Max. g Rotor Capacity Typical Sample Volume Particle Pathlength 32 000 102 000 1,675 mL 50-200 mL 7.5 cm Note: Solutions in the pH range of 4 to 10 can be used in this Titanium rotor. No. 969312 Type Ti-15 Titanium Zonal Rotor and Lid with Standard Core No. 969313 Type Ti-15 Titanium Zonal Rotor and Lid with B29 Core No. 369622 Type Ti-15 Titanium Zonal Rotor and Lid without Core All above include 332676 Push-Pull Cap and Spare Parts/Supplies – 335148 Vacuum Grease, 306812 Spinkote Lubricant, 2 extra 335456 Overspeed Disks, and O-rings. (Seal Assembly, Mounting Hardware, and Tool Kit also required.) Note: A continuous-output gradient pump able to operate against a backpressure of 20 psi (138 kPa) is also required. The purchased pump must be able to provide a flow of up to 50 mL/min. (3 L/hr) and the pump head must accept 1/8-in. (3-mm) I.D. tubing. We recommend a Masterflex pump that can be purchased directly from the manufacturer: www.masterflex.com Replacement Parts for the Ti-15 Rotor and the Discontinued Al-15 Rotor 328946 328949 332676 333857 335456 336821 Rotor Gasket Non-extrusion Ring Push-Pull Cap Rotor Core, Noryl 815472 O-ring, top of Rotor Core 011167 O-ring for Seal Fitting 812715 O-ring, bottom of Rotor Core 332682 Cone 011519 O-ring, interior of Cap 332691 Seal Fitting 012780 O-ring, visible, on Cap Ti-15 Overspeed Disk, 32 000 rpm Ti-15 Overspeed Disk, 29 000 rpm Tool Kits/Additional Parts 328917 332688 332690 333763 858532 Rotor Tool Kit Rotor Vise Spanner Wrench Tubing Removal Tool Pliers 332676 Push-Pull Capping Mechanism 011519 O-ring Inside Cap (Not Visible) 012780 O-ring (Visible) Rotor Lid 332682 Cone 815472 O-ring 332691 Seal Fitting 011167 O-ring for Fitting (Not Visible) 333857 Rotor Core 354192 961778 Standoff (qty. 3 req’d for field installations) Vibe Mount (qty. 3 req’d for field installations) 812715 O-ring B-29 Type Core for Al/Ti-15 Rotors No. 350474. This core for introduction of sample solution and recovery of fractions from the edge as well as the center of the zonal rotor is readily interchangeable with the standard cores. The ability to load the zonal rotor from the edge can greatly facilitate flotation-type runs. Also isopycnic banding in cesium chloride can be economically extended toTitanium zonal rotors with the B-19 Type core. 328949 Non-Extrusion Ring 328946 Rotor Gasket Reograd Type Core No. 352125. Gradient is loaded and unloaded while rotor is at rest. Gradient reorients during acceleration and reorients upon deceleration. Does not require zonal seal assembly or mounting hardware. The rotor is loaded using a special cap (supplied with the core) with inlet and outlet. The cap is replaced with the standard rotor cap for the run. This core is particularly useful for lipoprotein subfractionation. Beckman Coulter Ultracentrifuge Rotor Bowl 1-37 1 www.beckmancoultercentrifugation.com Ti-14 Ti-14 665 mL Zonal Rotor, Titanium DISCONTINUED 2006 For use in instruments classified: H S Major applications: Rate-zonal centrifugation of subcellular particles, rate-zonal flotation of lipoproteins. 1 Max. RPM Max. g Rotor Capacity Typical Sample Volume Particle Pathlength 48 000 172 000 665 mL 20-50 mL 5.3 cm Note: Solutions in the pH range of 4 to 10 can be used in this Titanium rotor. Replacement Parts for the Discontinued Ti-14 Rotor 328945 328948 332676 333856 330329 332619 332620 Rotor Gasket Non-extrusion Ring Push-Pull Cap Rotor Core, Noryl 815472 O-ring, top of Rotor Core 011167 O-ring for Seal Fitting 858506 O-ring, bottom of Rotor Core 332682 Cone 332691 Seal Fitting 011519 O-ring, interior of Cap 012780 O-ring, visible, on Cap Ti-14 Overspeed Disk, 42 000 rpm Ti-14 Overspeed Disk, 48 000 rpm Ti-14 Overspeed Disk, 35 000 rpm 332676 Push-Pull Capping Mechanism 011519 O-ring Inside Cap (Not Visible) 012780 O-ring (Visible) Tool Kits 328917 332688 332690 333763 858532 Rotor Tool Kit Rotor Vise Spanner Wrench Tubing Removal Tool Pliers B-29 Type Core for Ti-14 Rotors No. 350473. This core for introduction of sample solution and recovery of fractions from the edge as well as the center of the zonal rotor is readily interchangeable with the standard cores. The ability to load the zonal rotor from the edge can greatly facilitate flotation-type runs. Also, isopycnic banding in cesium chloride can be economically extended to Titanium zonal rotors wtih the B-29 Type Core. Rotor Lid 332682 Cone 815472 O-ring 332691 Seal Fitting 011167 O-ring for Fitting (Not Visible) 333856 Rotor Core 858506 O-ring 328948 Non-Extrusion Ring 328945 Rotor Gasket Note: A continuous-output gradient pump able to operate against a backpressure of 20 psi (138 kPa) is also required. The purchased pump must be able to provide a flow of up to 25 mL/min. (1.5 L/hr) and the pump head must accept 1/8-in. (3-mm) I.D. tubing. We recommend a Masterflex pump that can be purchased directly from the manufacturer: www.masterflex.com 1-38 Rotor Bowl Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Seal Assembly Seal Assembly For Zonal Rotors For use in instruments classified: H S 1 The Seal Assembly holds the lines through which fluids are introduced and withdrawn while the rotor is spinning at 2000 rpm. The assembly may be used with any of the Beckman Coulter zonal rotors in any Beckman Coulter preparative ultracentrifuge. An order of a Seal Assembly should include three part numbers: 1. Seal Assembly, 334241 2. Tool Kit, 328917 3. Appropriate Mounting Hardware If the Seal Assembly is to be used in more than one instrument, Mounting Hardware should be ordered for each instrument. If a Z-60 Rotor is to be run in an instrument in which the Ti-14 Rotor will be used, the 336830 Support Band Kit also should be ordered (no charge). Important Reminder: Seal Assemblies for earlier zonal rotors cannot be used with the new rotors. To distinguish the new Seal Assembly from the earlier version, check the rotating and stationary seals; in the newer assembly, both seals are contained in a single unit, in the manifold assembly (see diagram). 828628 Screw (8-32 x 5/8) 802173 Washer 328960 Bearing Cap 858505 Spring Mounting Hardware 337890 Hardware for any L8M, L8, Optima XL Optimas with Ti 15 rotors require each of the following parts: 354192 Standoff (quantity required: 3) 961778 Vibe Mount (quantity required: 3) We recommend the Cole Parmer #7520-40 Pump with #7015-21 Pump Head which can be purchased directly from the manufacturer: www.masterflex.com Installation Requirements The Mounting Hardware will be installed by a Beckman Coulter Service Representative at no extra cost. In addition to the Gradient Pump, the following installation necessities not supplied by Beckman Coulter are needed: a syringe (50 or 100 mL) for introducing sample, and two hemostats or other clamping devices to shut off tubing lines when necessary. 328954 Manifold Assembly 824412 O-ring (inner) 011167 O-ring (outer, top) 811656 O-ring 328952 Stationary Seal 328951 Rotating Rulon Seal 868638 O-ring Replacement Parts for Seal Assembly 011167 328951 328952 332618 333743 802173 811656 819527 824412 828628 868638 858505 328954 O-ring, top of Stationary Seal Rotating Rulon Seal, for Seal Assembly Stationary Seal, two-piece construction Seal Disassembly Tool Bearing and Assembly Washer, for Bearing Cup O-ring, outer perimeter, Stationary Seal O-ring, for Bearing Assembly O-ring, center top of Stationary Seal Screw, for Bearing Cup O-ring, for Rotating Seal Spring, for Seal Assembly Manifold 819527 O-ring 328959 Bearing Housing Tool Kits 328917 332688 332690 333763 858532 333743 Bearing and Seal Housing Assembly Rotor Tool Kit Rotor Vise Spanner Wrench Tubing Removal Tool Pliers Beckman Coulter Ultracentrifuge 1-39 www.beckmancoultercentrifugation.com Ultracentrifugation 1 Quick-Reference Guide to Rotor Specifications and Tabletop Ultracentrifuge Compatibility Max. RPM Max. g k Factor No. of Tubes x Nominal Tube Volume (mL) Nominal Rotor Capacity (mL) TLA-120.2≈ 120 000 627 000 16 10 x 2.0 20 TL-100, Optima TL, Optima TLX, Optima MAX-XP, Optima MAX-TL TLA-120.1 120 000 627 000 8 14 x 0.5 7 TL-100, Optima TL, Optima TLX, Optima MAX-XP, Optima MAX-TL TLA-110≈ 110 000 657 000 13 8 x 5.1 40.8 TL-100, Optima TL, Optima TLX, Optima MAX-XP, Optima MAX-TL TLA-100.3 100 000 541 000 14 6 x 3.5 21 TL-100, Optima TL, Optima TLX, Optima MAX-XP, Optima MAX-TL TLA-100 100 000 436 000 7 20 x 0.2 4 TL-100, Optima TL, Optima TLX, Optima MAX-XP, Optima MAX-TL TLA-55≈ 55 000 186 000 66 12 x 1.5 18 TL-100, Optima TL, Optima TLX, Optima MAX-XP, Optima MAX-TL TLS-55 55 000 259 000 50 4 x 2.2 8.8 TL-100, Optima TL, Optima TLX, Optima MAX-XP, Optima MAX-TL TLN-120 120 000 585 000 7 8 x 1.2 9.6 TL-100, Optima TL, Optima TLX, Optima MAX-XP, Optima MAX-TL TLN-100 100 000 450 000 14 8 x 3.9 31.2 TL-100, Optima TL, Optima TLX, Optima MAX-XP, Optima MAX-TL MLA-150 150 000 1 003 000 10.4 8 x 2.0 16 Optima MAX-XP MLA-130 130 000 1 019 000 8.7 10 x 2.0 20 Optima MAX-XP MLA-80 80 000 444 000 29 8x8 64 Optima MAX-XP MLA-55 55 000 287 000 53 8 x 13.5 108 Optima MAX-XP MLA-50 50 000 233 000 92 6 x 32.4 194.4 Optima MAX-XP MLS-50 50 000 268 000 71 4x5 20 Optima MAX-XP MLN-80 80 000 389 000 20 8x8 64 Optima MAX-XP A-110 110 000 199 000 9 6 x 180 µL 1 080 µL Airfuge A-100/30 92 000 167 000 19 6 x 240 µL 1 440 µL Airfuge A-100/18 95 000 148 000 12 6 x 175 µL 1 050 µL Airfuge A-95 95 000 178 000 19 4 x 450 µL 1 800 µL Airfuge ACR-90 90 000 122 000 45 NA 3.5 mL Airfuge Batch Rotor 90 000 132 000 55 NA 7 mL Airfuge EM-90 90 000 118 000 NA 6 x 100 µL 600 µL Airfuge Rotor ≈ For Use in Instruments This rotor has been tested to demonstrate containment of microbiological aerosols only while operating within the associated Beckman Coulter centrifuge. 1-40 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Ultracentrifugation Beckman Coulter Tabletop Rotors by Use* n n n Fastest Rate-Zonal Separation n n n n n n Fastest Rate-Zonal Separation n n n Fastest Separation n n n n n n n n n n n n n n n n n n n n n n Largest Number for Differential Flotation n n n n n MLN-80 TLN-100 n n n n n n n n n n n n n n n n n n n n n n n n n n n Greatest Interband Space n n n n n n n n n n n n Largest Volume n n Largest Volume for Differential Flotation Fastest Separation n n n n n Greatest Interband Distance Isopycnic Separation of Plasmid DNA n n n Fastest Differential Flotation Fastest Separation n n Largest Volume Pelleting RNA Through a CsCI Gradient n TLN-120 n n MLS-50 n n TLS-55 n MLA-50 n TLA-55 TLA-100 TLA-100.3 n n n Largest Number of Samples Separation of Lipoproteins n n Largest Volume Rate-Zonal Separation Rate-Zonal Separation of Proteins in Sucrose Gradient n n Largest Volume for Pelleting Fastest Pelleting n MLA-55 n Largest Volume Rate-Zonal Separation Separation of Viruses and Viral Particles TLA-110 n MLA-80 Fastest Pelleting TLA-120.1 Largest Volume for Pelleting TLA-120.2 Separation of Subcellular Particles MLA-130 Specific Application MLA-150 Bioseparation 1 n n n n n n n n n n n n n n n n n n n n n n n n Greatest Interband Distance n n n n Largest Volume n n n n n n n n n n n n n n n n n n n *Selected rotor has the capability (RCF, volume, labware) to accommodate the application, but may not be the most optimal/efficient choice for the specific application. Beckman Coulter Ultracentrifuge 1-41 www.beckmancoultercentrifugation.com TLA-120.2≈ TLA 120.2 Fixed-Angle Rotor, Titanium Axis of Rotation 1 TLA-120.2 10 x 2.0 mL For use in the TL-100, Optima TL, Optima TLX, Optima MAX-XP and Optima MAX-TL ultracentrifuges. rmin (24.5 mm) rav (31.8 mm) rmax (38.9 mm) Major applications: Pelleting of subcellular fractions in 5-30 minutes, plasmid DNA separation in 3 hours. 30° Max. RPM Max. g k Factor 120 000 627 000 16 Number of Tubes Volume/Size Rotor Capacity 10 x 2.0 mL 11 x 34 mm 20 mL No. 357656. TLA-120.2 Fixed-Angle Rotor Package. Includes BioCertified Rotor, 1 box 343778 Thickwall Polycarbonate Tubes, 1 each 348305 Tube Rack, 346133 Rotor Vise/Stand, 927208 Hemostats, 824412 and 854519 O-rings, 306812 Spinkote Lubricant, and 355148 Vacuum Grease. No. 362046. TLA-120.2 Fixed-Angle Rotor Assembly. Tubes and Bottles Tube Style/Material Quick-Seal Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Vol.(mL) g-Max Part No. Quantity Size (mm) Floating Spacers (qty. 1) Adapters (qty. 1) g-Force 1.5 2.0 1.0 344624 344625 347287 50 50 100 11 x 25 11 x 32 11 x 34 344636 344674 ——— ——— ——— ——— 627 000 627 000 279 000 14 16 18 120 000 120 000 80 000 1.0 343778 100 11 x 34 ——— ——— 627 000 8 120 000 Rotor Accessories Rotor Replacements Parts 301875 Spacer Removal Tool 345531 Quick-Seal Starter Kit, 11 x 25 mm, 1.5 mL Tubes. Includes 10 each 344636 Spacers, box of 344624 Tubes and 8 each 344643 Adapters (349387 Tube Topper Rack required). 345532 Quick-Seal Starter Kit, 11 x 32 mm, 2.0 mL Tubes. Includes 10 each 367310 Spacers, box of 344625 Tubes and 8 each 344644 Adapters (349387 Tube Topper Rack required). 346133 Rotor Vise Assembly 348305 Tube Rack for 11-mm Tubes (included with Rotor Package) 349387 Tube Topper Rack for 11-mm Tubes 349487 Quick-Seal Tube Rack (Tube Rack Adapters required)√√ 362100 Tube Rack Adapter (set/8) for sealing Tubes 344624* 362101 Tube Rack Adapter (set/8) for sealing Tubes 344625* 927208 Hemostats, 6-in. curved 349318 362048 824412 854519 * k Factor Max. Speed Cap & Plunger Assembly Rotor Lid Assembly O-ring (inner, Rotor Lid) O-ring (outer, Rotor Lid) Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. √ √ Required for obsolete Bench Quick Sealer. ≈ This rotor has been tested to demonstrate containment of microbiological aerosols only while operating within the associated Beckman Coulter centrifuge. Adapters/Spacers 344636 1-42 344674 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com TLA-120.1 TLA-120.1 14 x 0.5 mL TLA 120.1 Fixed-Angle Rotor, Titanium Axis of Rotation For use in the TL-100, Optima TL, Optima TLX, Optima MAX-XP and Optima MAX-TL ultracentrifuges. Major applications: Pelleting of subcellular fractions in 5-30 minutes; plasmid DNA separation in 3 hours. rmin (24.5 mm) rav (31.8 mm) rmax (38.9 mm) 30° Max. RPM Max. g 120 000 627 000 k Factor 8 Number of Tubes Volume/Size Rotor Capacity 14 x 0.5 mL 8 x 34 mm 7 mL No. 357655. TLA-120.1 Fixed-Angle Rotor Package. Includes Rotor, 1 box 343776 Thickwall Polycarbonate Tubes, 1 each 348304 Tube Rack, 346133 Rotor Vise/Stand, 927208 Hemostats, 824412 and 854519 O-rings, 306812 Spinkote Lubricant, and 355148 Vacuum Grease. No. 362224. TLA-120.1 Fixed-Angle Rotor Assembly. Tubes and Bottles Tube Style/Material Thickwall Polyallomer Thickwall Polycarbonate Vol.(mL) Part No. Quantity Size (mm) Floating Spacers Adapters g-Force 0.5 343777 100 8 x 34 ——— ——— 279 000 18 80 000 0.5 343776 100 8 x 34 ——— ——— 627 000 8 120 000 Rotor Accessories Rotor Replacement Parts 346133 347404 348305 927208 349318 362225 824412 854519 Rotor Vise/Stand Rotor Cleaning Brush Tube Rack for 8-mm Tubes (included with Rotor Package) Hemostats Beckman Coulter Ultracentrifuge k Factor Max. Speed Cap & Plunger Assembly Rotor Lid Assembly (O-rings not included) O-ring (inner, Rotor Lid) O-ring (outer, Rotor Lid) 1-43 1 www.beckmancoultercentrifugation.com TLA-110≈ TLA-110 8 x 5.1 mL TLA 100.4 Fixed-Angle Rotor, Titanium Axis of Rotation 1 For use in the TL-100, Optima TL, Optima TLX, Optima MAX-XP and Optima MAX-TL ultracentrifuges. Major applications: Moderate volume differential sedimentation (pelleting) of subcellular organelles and viruses. rmin (26.0 mm) rav (37.2 mm) rmax (48.5 mm) Max. RPM Max. g k Factor 110 000 657 000 13 28° Number of Tubes Volume/Size Rotor Capacity 8 x 5.1 mL 13 x 56 mm 40.8 mL No. 366735. TLA-110 Fixed-Angle Rotor Package. Includes BioCertified Rotor, 1 box of 361621 OptiSeal Tubes, 8 each 361676 Floating Spacers, 854519 and 824412 O-ring, 348122 Tube Rack, 927208 Hemostats, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. No. 366730. TLA-110 Fixed-Angle Rotor Assembly. Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Bell Top Quick-Seal Polyallomer Bell Top Thickwall Polyallomer Thickwall Polycarbonate Microcentrifuge Polyallomer Corning Screw Cap Polypropylene Vol.(mL) Part No. Quantity Size (mm) Floating Spacers (qty. 8) Adapters (qty. 8) g-Force 4.7 361621 56 13 x 48 361676§§ —–— 657 000 12 110 000 2.0 3.5 5.1 3.2 345829 349621 362248 362333 50 50 50 50 13 x 25 13 x 32 13 x 51 13 x 56 360270 360270 362307 —–— —–— —–— —–— —–— 657 000 657 000 657 000 267 000 5 7 13 37 110 000 110 000 110 000 70 000 3.2 362305 50 13 x 56 —–— —–— 657 000 13 110 000 1.5 357448 500 11 x 38 —–— 360951 206 000 19 70 000 1.5 *** —–— n/a —–— 393238 536 000 9 110 000 *§§ Set of 2. ≈ This rotor has been tested to demonstrate containment of microbiological aerosols only while operating within the associated Beckman Coulter centrifuge. Rotor Accessories 306812 Spinkote Lubricant (2 oz) 335148 Silicone Vacuum Grease 338765 Spacer Removal Tool for 3.5-mL and 2.0-mL Quick-Seal Tube Spacers 339555 Beckman Solution 555 (1 qt) 339558 Rotor Cleaning Kit 342025 Fraction Recovery System 345832 Tube Rack Adapter for 13 x 25 mm, 2.0-mL Quick-Seal Tubes for use in 349487 Tube Rack√√ 347404 Rotor Cleaning Brush 347828 Fraction Recovery System Adapter Kit for TL-series tubes 347960 Centri-Tube Slicer 348122 Tube Topper Rack for 13-mm Tubes (included in Rotor Package) 348299 CentriTube Slicer Replacement Blades (pkg of 10) 349487 Tube Rack for g-Max Quick-Seal Tubes√√ 354526 CentriTube Slicer Adapter for 13mm tubes 355582 Tube Rack Adapter for 13 x 32 mm, 3.5-mL Quick-Seal Tubes for use in 349487 Tube Rack√√ k Factor Max. Speed *** Corning P/N 430909. Commercially available product. Beckman Coulter does not sell Corning tubes. 355872 358312 358313 358314 358315 361638 361668 927208 961519 Tube Rack for 13-mm Tubes Quick-Seal Cordless Tube Topper Kit, 60 Hz Quick-Seal Cordless Tube Topper Kit, 50 Hz (Europe) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Great Britain) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Australia) OptiSeal Tube Rack Assembly Tube Removal Tool Hemostats, 6-in. curved Hemostat, 6 in. straight √ √ Required for obsolete Bench Quick Sealer. Rotor Replacement Parts 346133 347903 349477 366732 824412 854519 Rotor Vise Spring Cap & Plunger Assembly Rotor Lid Assembly O-ring (inner, Rotor Lid) O-ring (outer, Rotor Lid) Adapters/Spacers 360270 360951 361676 362307 393238 Adapter for Corning Screw Cap Tube (CorningP/N430909). 1-44 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com TLA-100.3 TLA-100.3 6 x 3.5 mL TLA 100.3 Fixed-Angle Rotor, Titanium For use in the TL-100, Optima TL, Optima TLX, Optima MAX-XP and Optima MAX-TL ultracentrifuges. Axis of Rotation Note: Non-precipitating solutions up to 1.7 g/mL in density can be run in this rotor without a reduction in rotor speed. rmin (27.5 mm) rav (37.9 mm) rmax (48.3 mm) Major applications: Pelleting of subcellular fractions in 5-30 minutes; pelleting RNA in 1-2 hours; plasmid DNA separation in 6 hours. 30° Max. RPM Max. g k Factor 100 000 541 000 14 Number of Tubes Volume/Size Rotor Capacity 6 x 3.5 mL 13 x 51 mm 21 mL No. 349481. TLA-100.3 Fixed-Angle Rotor Assembly. No. 349490. TLA-100.3 Fixed-Angle Rotor Package. Includes Rotor, 1 box 349622 Thickwall Polycarbonate Tubes, 1 box 349623 Thickwall Polyallomer Tubes, 1 each 355919 (pkg. of 6) Spacers for 1.5 mL Microcentrifuge Tubes, 355872 Tube Rack, 824412 and 854521 O-rings, 927208 Hemostats, 346133 Rotor Vise/Stand, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. Tubes and Bottles Tube Style/Material Vol. (mL) g-Max Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 6) Required Adapters (qty. 6) Quick-Seal Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Microcentrifuge Polyallomer 2.0 3.5 3.0 345829 349621 349623 50 50 25 13 x 25 13 x 32 13 x 51 360270◊◊◊ 355937 ——— ——— ——— ——— 541 000 541 000 265 000 11 14 34 100 000 100 000 70 000 3.0 349622 25 13 x 51 ——— ——— 541 000 16 100 000 1.5 357448 500 11 x 38 ——— 355919 245 000 24 70 000 g-Force k Factor Max. Speed Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. ◊◊◊ Package of 8. Rotor Accessories 306812 Spinkote Lubricant (2 oz) 335148 Silicone Vacuum Grease 338765 Spacer Removal Tool for 3.5-mL and 2.0-mL Quick-Seal Tube Spacers 339555 Beckman Solution 555 (1 qt) 339558 Rotor Cleaning Kit 342025 Fraction Recovery System 345832 Tube Rack Adapter for 13 x 25 mm, 2.0-mL Quick-Seal Tubes for use in 349487 Tube Rack√√ 347404 Rotor Cleaning Brush 347828 Fraction Recovery System Adapter Kit for TL-series tubes 347960 Centri-Tube Slicer 348122 Tube Topper Rack for 13-mm Tubes 348299 CentriTube Slicer Replacement Blades (pkg of 10) 349487 Tube Rack for Quick-Seal Tube Sealer, 8-place (Adapters required)√√ 354526 CentriTube Slicer Adapter for 13mm tubes 355582 Tube Rack Adapter for 13 x 32 mm, 3.5-mL Quick-Seal Tubes for use in 349487 Tube Rack√√ 355872 Tube Rack for 13-mm Tubes (included in Rotor Package) 358312 Quick-Seal Cordless Tube Topper Kit, 60 Hz 358313 358314 358315 361668 927208 961519 Quick-Seal Cordless Tube Topper Kit, 50 Hz (Europe) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Great Britain) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Australia) Tube Removal Tool Hemostat, 6 in. curved Hemostat, 6 in. straight √ √ Required for obsolete Bench Quick Sealer. Rotor Replacement Parts 346133 347903 349477 349478 824412 854521 Rotor Vise Spring Cap & Plunger Assembly Rotor Lid Assembly O-ring (inner, Rotor Lid) O-ring (outer, Rotor Lid) Adapters/Spacers 355919 355937 360270 Beckman Coulter Ultracentrifuge 1-45 1 www.beckmancoultercentrifugation.com TLA-100 TLA-100 20 x 0.2 mL TLA 100 Fixed-Angle Rotor, Titanium For use in the TL-100, Optima TL, Optima TLX, Optima MAX-XP and Optima MAX-TL ultracentrifuges. Axis of Rotation 1 Note: Non-precipitating solutions up to 1.7 g/mL in density can be run in this rotor without a reduction in rotor speed. rmin (30.0 mm) rav (34.5 mm) rmax (38.9 mm) Major applications: Pelleting of subcellular fractions; proteins; RNA. 30° Max. RPM Max. g 100 000 436 000 k Factor 7 Number of Tubes Volume/Size Rotor Capacity 20 x 0.2 mL 7 x 20 mm 4 mL No. 343837. TLA-100 Fixed-Angle Rotor Package. Includes Rotor, 1 box 343775 Thickwall Polycarbonate Tubes, 1 each 348302 Tube Rack, 824412 and 824953 O-rings, 927208 Hemostats, 346133 Rotor Vise/ Stand, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. No. 343840. TLA-100 Fixed-Angle Rotor Assembly. Tubes and Bottles Tube Style/Material Thickwall Polyallomer Thickwall Polycarbonate Thickwall Cellulose Propionate Vol.(mL) Part No. Quantity Size (mm) Floating Spacers (qty. 1) Adapters (qty. 1) g-Force 0.2 343621 100 7 x 20 ——— ——— 279 000 10 80 000 0.2 343775 100 7 x 20 ——— ——— 436 000 7 100 000 0.2 342303 100 7 x 20 ——— ——— 184 000 16 65 000 Rotor Accessories Rotor Replacement Parts 306812 335148 339555 339558 342025 347404 347828 347960 348299 348302 361668 927208 961519 343845 346133 349318 824412 824953 1-46 Spinkote Lubricant (2 oz) Silicone Vacuum Grease Beckman Solution 555 (1 qt) Rotor Cleaning Kit Fraction Recovery System Rotor Cleaning Brush Fraction Recovery System Adapter Kit for TL-series tubes Centri-Tube Slicer CentriTube Slicer Replacement Blades (pkg of 10) Tube Rack for 7-mm Tubes (included with Rotor Package) Tube Removal Tool Hemostats, 6-in. curved Hemostat, 6 in. straight k Factor Max. Speed Rotor Lid Assembly (O-rings not included) Rotor Vise Cap & Plunger Assembly O-ring (inner, Rotor Lid) O-ring (outer, Rotor Lid) Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com TLA-55≈ TLA-55 12 x 1.5 mL TLA 45 Fixed-Angle Rotor, Aluminum Axis of Rotation For use in the TL-100, Optima TL, Optima TLX, Optima MAX-XP and Optima MAX-TL ultracentrifuges. Major applications: Rapid pelleting of nucleic acid precipitates in 1.5 mL tubes. rmin (25 mm) rav (40 mm) rmax (55 mm) Max. RPM Max. g k Factor 55 000 186 000 66 45° Number of Tubes Volume/Size Rotor Capacity 12 x 1.5 mL 11 x 38 mm 18 mL No. 366725. TLA-55 Fixed-Angle Rotor Package. Includes BioCertified Rotor, 1 box 357448 Microcentrifuge Tubes, 1 each 824412 and 824644 O-rings, 348122 Tube Rack, 927208 Hemostats, 306812 Spinkote Lubricant and 335148 Vacuum Grease. Tubes and Bottles Tube Style/Material Vol. (mL) Part No. Quantity Microcentrifuge Polyallomer 1.5 357448 500 Size (mm) 11 x 38 Required Caps/ Spacers (qty. 1) ——— Required Adapters (qty. 1) ——— Rotor Accessories Rotor Replacement Parts 347404 Rotor Cleaning Brush 348122 Tube Rack 927208 Hemostats, 6-in curved 349318 366722 824412 824644 ≈ g-Force 186 000 k Factor 66 Max. Speed 55 000 Cap & Plunger Assembly Rotor Lid Assembly O-ring (Inner, Rotor Lid) O-ring (Outer, Rotor Lid) This rotor has been tested to demonstrate containment of microbiological aerosols only while operating within the associated Beckman Coulter centrifuge. Beckman Coulter Ultracentrifuge 1-47 1 www.beckmancoultercentrifugation.com MLA-150 MLA-150 8 x 2.0 mL Fixed-Angle Rotor, Titanium 30° For use in the Optima MAX-XP ultracentrifuge. Major applications: Rapid differential sedimentation (pelleting) of small particles such as subcellular organelles and viruses. 1 Max. RPM 150 000 rmin (15.8 mm) rav (27.8 mm) rmax (39.9 mm) Max. g k Factor 1 003 000 10.4* Number of Tubes Volume/Size Rotor Capacity 8 x 2.0 mL 11 x 32 mm 16 mL * Based on cell hole dimensions. k-Factor = 4.58 if run with 1 mL sample and open top tube. Axis of rotation No. 393490. MLA-150 Rotor Package. Includes Rotor, 1 box 344625 Quick-Seal Polyallomer Tubes, 1 each 393570 (pkg of 8) Spacers, 349387 Tube Rack, 860218 O-ring, 927208 Hemostats, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. No. 393489. MLA-150 Fixed-Angle Rotor Assembly. Tubes and Bottles Tube Style/Material Quick-Seal Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Vol. (mL) Part No. Quantity Size (mm) Floating Spacers (qty. 8) Adapters (qty. 1) g-Force k Factor 1.5 2.0 1.0 344624 344625 347287 50 50 100 11 x 25 11 x 32 11 x 34 393570 393570 —–— —–— —–— —–— 989 000 989 000 387 000 6.2 8.0 11.4 150 000 150 000 95 000 1.0 343778 100 11 x 34 —–— —–— 964 000 4.6 150 000 Rotor Accesories Rotor Replacement Parts 306812 335148 339555 339558 342025 347404 347828 349387 358312 358313 358314 358315 361668 927208 961519 393485 Rotor Lid Assembly 860218 O-ring for Lid Spinkote Lubricant (2 oz) Silicone Vacuum Grease Beckman Solution 555 (1 qt) Rotor Cleaning Kit Fraction Recovery System Rotor Cleaning Brush Fraction Recovery System Adapter Kit for TL-series tubes Tube Topper Rack Quick-Seal Cordless Tube Topper Kit, 60 Hz Quick-Seal Cordless Tube Topper Kit, 50 Hz (Europe) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Great Britain) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Australia) Tube Removal Tool Hemostat, 6 in. curved Hemostat, 6 in. straight Max. Speed Adapters/Spacers 393570 1-48 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com MLA-130 MLA-130 10 x 2.0 mL Type 28 Fixed-Angle Rotor, Titanium Axis of Rotation rmin (29.9 mm) For use in the Optima MAX-XP ultracentrifuge. Major applications: Rapid differential sedimentation (pelleting) of small particles such as subcellular organelles and viruses. rav (41.9 mm) Max. RPM rmax (53.9 mm) 130 000 Max. g k Factor 1 019 000 8.7 35° Number of Tubes Volume/Size Rotor Capacity 10 x 2.0 mL 11 x 32 mm 20 mL No. 367114. MLA-130 Fixed-Angle Rotor Package. Includes Rotor, 1 box 344625 Quick-Seal Polyallomer Tubes, 10 each 367310 Spacers, 1 each 349387 Tube Rack, 975001 O-ring, 927208 Hemostats, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. No. 367120. MLA-130 Fixed-Angle Rotor Assembly. Tubes and Bottles Tube Style/Material Quick-Seal Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Vol. (mL) Part No. Quantity Size (mm) Floating Spacers (qty. 1) Adapters (qty. 1) 1.5 2.0 1.0 344624 344625 347287 50 50 100 11 x 25 11 x 32 11 x 34 367310 367310 —–— —–— —–— —–— 1 019 000 1 019 000 390 000 7.0 8.7 23 130 000 130 000 80 000 1.0 343778 100 11 x 34 —–— —–— 1 019 000 5.8 130 000 Rotor Accesories Rotor Replacement Parts 306812 335148 339555 339558 342025 347404 347828 349387 358312 358313 358314 358315 361668 927208 961519 347373 Rotor Vise 367115 Rotor Lid 975001 O-ring for Lid Spinkote Lubricant (2 oz) Silicone Vacuum Grease Beckman Solution 555 (1 qt) Rotor Cleaning Kit Fraction Recovery System Rotor Cleaning Brush Fraction Recovery System Adapter Kit for TL-series tubes Tube Topper Rack Quick-Seal Cordless Tube Topper Kit, 60 Hz Quick-Seal Cordless Tube Topper Kit, 50 Hz (Europe) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Great Britain) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Australia) Tube Removal Tool Hemostat, 6 in. curved Hemostat, 6 in. straight g-Force k Factor Max. Speed Adapters/Spacers 367310 Beckman Coulter Ultracentrifuge 1-49 1 www.beckmancoultercentrifugation.com MLA-80 MLA-80 8 x 8 mL Type 50 Ti Fixed-Angle Rotor, Titanium Axis of Rotation For use in the Optima MAX-XP ultracentrifuge. Major applications: Large volume differential sedimentation (pelleting) of subcellular organelles and viruses. rmin (29.5 mm) rav (45.7 mm) rmax (61.9 mm) 1 Max. RPM Max. g k Factor 80 000 444 000 29 Number of Tubes Volume/Size Rotor Capacity 8 x 8 mL 16 x 64 mm 26° 64 mL No. 367096. MLA-80 Fixed-Angle Rotor Package. Includes Rotor, 1 box 344621 Quick-Seal Polyallomer Tubes, 10 each 367094 Spacers, 1 each 348123 Tube Rack, 927208 Hemostats, 338765 Spacer Removal Tool, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. Tubes and Bottles Tube Style/Material Quick-Seal Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Vol. (mL) Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) g-Force k Factor 4.2 6.3 8.0 6.5 356562 345830 344621 355646 50 50 50 25 16 x 38 16 x 45 16 x 58 16 x 64 367094 367094 367094 ——— ——— ——— ——— 444 000 444 000 444 000 84 900 18 23 29 153 80 000 80 000 80 000 35 000 6.5 355647 25 16 x 64 ——— 417 000 19 80 000 Rotor Accessories Rotor Replacement Parts 306812 335148 338765 339555 339558 347404 348123 358312 358313 358314 358315 361668 927208 961519 346133 Rotor Vise 367089 Rotor Lid 892292 O-ring Spinkote Lubricant (2 oz) Silicone Vacuum Grease Floating Spacer Removal Tool Beckman Solution 555 (1 qt) Rotor Cleaning Kit Rotor Cleaning Brush Tube Topper Rack Quick-Seal Cordless Tube Topper Kit, 60 Hz Quick-Seal Cordless Tube Topper Kit, 50 Hz (Europe) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Great Britain) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Australia) Tube Removal Tool Hemostat, 6 in. curved Hemostat, 6 in. straight Max. Speed Adapters/Spacers 367094 1-50 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com MLA-55 MLA-55 8 x 13.5 mL Fixed-Angle Rotor, Aluminum 35° For use in the Optima MAX-XP ultracentrifuge. Major applications: Plasmid DNA Separations. rmin rav rmax rmin (45.0 mm) rav (64.0 mm) rmax (84.5 mm) Max. RPM Max. g k Factor 55 000 287 000 53 Number of Tubes Volume/Size Rotor Capacity 8 x 13.5 mL 16 x 76 mm 108 mL Axis of Rotation No. A31459. MLA-55 Fixed-Angle Rotor Package. Includes Rotor, 4 boxes of OptiSeal Tubes 361623, 12 spacers 361670 (6 pkg. of 2), 1 OptiSeal Tube Rack 361642, 1 Tube Extraction Tool 361668, and 1 Spacer Removal Tool 338765. No. 393203, MLA-55 Fixed-Angle Rotor Assembly. No. 348179. Quick-Seal Tube Kit with 2 boxes 342413 Polyallomer Tubes, 2 boxes 344322 Ultra-Clear Tubes, 12 each 342695 Spacers, 1 each 348123 Tube Rack, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. (Cordless Tube Topper Kit required; see Tools, Accessories, and Supplies.) No. 348180. Open-Top Tube Kit with 2 boxes 326814 Polyallomer Tubes, 2 boxes 344085 Ultra-Clear Tubes, 12 each 341968 Tube Caps, 1 each 306812 Spinkote Lubricant, and 335148 Vacuum Grease. (331202 and 305075 Tools required; see Tools, Accessories, and Supplies.) Tubes and Bottles Tube Style/Material Vol. (mL) g-Max Part No. Quantity Size (mm) OptiSeal Bell-Top Polycarbonate Bottle Assembly Quick-Seal Polyallomer 8.9 10.4 361623 355603 56 6 16 x 60 16 x 76 4.2 4.2 6.3 6.3 10.0 13.5 13.5 356562 357332§ 345830 357334§ 344622 342413 344322 50 50 50 50 50 50 50 4.0 10.0 4.0 10.0 6.5 13.5 2.0 4.0 6.5 13.5 355644 355640 355645 355630 326820 326814 344091 344093 344088 344085 25 25 25 25 50 50 50 50 50 50 Quick-Seal Ultra-Clear Thickwall Polyallomer Thickwall Polycarbonate Thinwall Polyallomer Ultra-Clear Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) g-Force k Factor Max. Speed 361670§§ ——— ——— ——— 289 996 288 658 52 67 55 000 55 000 16 × 38 16 × 38 16 × 45 16 × 45 16 x 67 16 x 76 16 x 76 345828 345828 345828 345828 344676 342695 342695 ——— ——— ——— ——— ——— ——— ——— 289 335 289 335 289 335 289 335 289 335 289 335 289 674 28 28 37 37 60 77 74 55 000 55 000 55 000 55 000 55 000 55 000 55 000 13 × 64 16 x 76 13 × 64 16 x 76 13 x 64 16 x 76 8 x 49 13 × 41 13 x 64 16 x 76 ——— 338907 ——— 338907 346256 341968 303624 346256 346256 341968 303313 ——— 303313 ——— 303313 ——— 303376 303402 303313 ——— 214 200 85 176 214 200 286 286 215 880 289 335 143 718 145 379 215 600 291 029 52 177 52 53 56 59 80 53 57 61 50 000 30 000 50 000 55 000 50 000 55 000 40 000 45 000 50 000 55 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. § To simplify ordering, this g-MaxKitincludesenoughspacerstofillrotor,50tubesandrequiredtools. §§ Set of 2. Adapters/Spacers 303313 303376 303402 303624 Beckman Coulter Ultracentrifuge 338907 341968 346256 342695 344676 345828 361670 1-51 1 www.beckmancoultercentrifugation.com MLA-55 (cont’d) MLA-55 8 x 13.5 mL 1 Rotor Accessories Rotor Replacement Parts 301875 305075 306812 331202 347373 393206 393210 839347 876089 335148 338765 339379 339555 339558 348123 358312 358313 358314 358315 361642 361668 841883 1-52 Tube Removal Tool Tube-Cap Vise Spinkote Lubricant (2 oz) Tool Kit for Aluminum Caps Includes: 858121 Torque Wrench 858122 Socket Adapter 858123 Socket for 19 mm Hex Nuts 870432 Socket for 11-mm Hex Nuts 301875 Removal Tool, for capped tubes Silicone Vacuum Grease Floating Spacer Removal Tool Rotor Cleaning Brush Beckman Solution 555 (1 qt) Rotor Cleaning Kit Tube Topper Rack Quick-Seal Cordless Tube Topper Kit, 60 Hz Quick-Seal Cordless Tube Topper Kit, 50 Hz (Europe) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Great Britain) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Australia) OptiSeal Tube Rack Assembly Tube Removal Tool for Quick-Seal and OptiSeal Tubes Hex Driver for 11-mm Cap Nuts on Stainless Steel Tubes Rotor Vise Rotor Handle Rotor Lid Handle O-Ring (Small) Lid O-Ring (Large) Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com MLA-50 MLA-50 6 x 32.4 mL 30° Fixed-Angle Rotor, Aluminum For use in the Optima MAX-XP ultracentrifuge. Major applications: Large volume separations of subcellular particles, viruses, lipoproteins, RNA, and plasmid DNA. rmin rav rmax rmin (33.6 mm) rav (58.4 mm) rmax (83.2 mm) Max. RPM Max. g k Factor 50 000 233 000 92 Axis of Rotation Number of Tubes Volume/Size Rotor Capacity 6 x 32.4 mL 25 x 77 mm 194.4 mL No. A91774. MLA-50 Fixed-Angle Rotor Assembly. Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal Ultra-Clear Thinwall Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Vol. (mL) Part No. Quantity Size (mm) 32.4 361625 56 25 x 77 15.0 15.0 27.0 27.0 15.0 27.0 6.5 13.5 4.0 10.0 4.0 10.0 343664 357343 § 343665 357346 § 344324 344323 326820 326814 355644 355640 344645 344630 50 50 50 50 50 50 50 50 25 25 25 25 25 × 38 25 x 38 25 x 64 25 x 64 25 × 38 25 x 64 13 x 64 16 x 76 13 x 64 16 x 76 13 x 64 16 x 76 Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) Max RCF (x g) k Factor Max. Speed (rpm) 361669§§ ——— 233 000 92 50 000 343448 343448 343448 343448 343448 343448 346256 330860 ——— 338907 ——— 338907 ——— ——— ——— ——— ——— ——— 303392 303307 303392 303307 303392 303307 233 000 233 000 233 000 233 000 233 000 233 000 189 000 209 000 187 000 206 000 187 000 206 000 50 50 79 79 50 79 76 94 52 89 52 89 50 000 50 000 50 000 50 000 50 000 50 000 50 000 50 000 50 000 50 000 50 000 50 000 Note: To help you locate g-Max tubes in the rotor listings, these tubes are highlighted with bold, italic type. §§ Set of 2. § To simplify ordering, this g-Max Kit includes 50 tubes, 12 spacers, a spacer removal tool and forceps Rotor Accessories Rotor Replacement Parts 306812 Spinkote Lubricant (2 oz) 331202 Hex Driver for 11-mm Cap Nuts on Stainless Steel Tubes 331202 Tool Kit for Aluminum Caps Includes: 301875 Removal Tool, for capped tubes 858121 Torque Wrench 858122 Socket Adapter 858123 Socket for 19 mm Hex Nut 870432 Socket for 11 mm Hex Nut 335148 Silicone Vacuum Grease 338765 Floating Spacer Removal Tool 339379 Rotor Cleaning Brush 339555 Beckman Solution 555 (1 qt) 339558 Rotor Cleaning Kit 348122 Tube Topper Rack 348123 Tube Topper Rack 348124 Quick-Seal Tube Topper Rack 358312 Quick-Seal Cordless Tube Topper Kit, 60 Hz 358313 Quick-Seal Cordless Tube Topper Kit, 50 Hz (Europe) 358314 Quick-Seal Cordless Tube Topper Kit, 50 Hz (Great Britain) 358315 Quick-Seal Cordless Tube Topper Kit, 50 Hz (Australia) 361646 OptiSeal Tube Rack Assembly 361668 Tube Removal Tool for Quick-Seal and OptiSeal Tubes 011521 A91766 A92167 A96399 Handle O-Ring (Small) Rotor Lid Lid O-Ring (Large) Rotor Handle Adapters/Spacers 303307 303392 330860 338907 Beckman Coulter Ultracentrifuge 343448 346256 361669 1-53 1 www.beckmancoultercentrifugation.com TLN-120 TLN-120 8 x 1.2 mL NVT Near-Vertical Rotor, Titanium Axis of Rotation 1 rmin (24.3 mm) For use in the TL-100*, Optima TL, Optima TLX, Optima MAXXP and Optima MAX-TL ultracentrifuges. rav (30.3 mm) Major applications: Plasmid DNA Separations in 11/2 hours.** Note: Non-precipitating solutions up to 1.7 g/mL in density can be run in this rotor without a reduction in rotor speed. rmax (36.3 mm) 8° Max. RPM Max. g k Factor 120 000 585 000 7 Number of Tubes Volume/Size Rotor Capacity 8 x 1.2 mL 8 x 35 mm 9.6 mL No. 357683. TLN-120 Near-Vertical Package. Includes Rotor, 1 box 361082 Quick-Seal Polyallomer Tubes, 10 each 361061 Spacers, 12 each 347371 Rotor Plug Gaskets, 1 each 348302 Tube Rack, 347373 Rotor Vise/Stand, 927208 Hemostats, 858121 Torque Wrench, 976959 Torx Wrench Adapter, and 306812 Spinkote Lubricant. Tubes and Bottles Tube Style/Material Quick-Seal Polyallomer Vol. (mL) Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) g-Force 1.2 361082 50 8 x 35 361061 ——— 585 000 k Factor 7 Max. Speed 120 000 ** To accommodate the TLN-120 Rotor, the TL-100 ultracentrifuge must be updated withanewdrivespindleandoperatingsoftware(modificationkitnumber360477). ** Using Optima MAX-XP, Optima MAX-TL or Optima TLX. Rotor Accessories Rotor Replacement Parts 306812 338765 339555 339558 347402 347404 347960 348299 348304 349661 354526 358312 358313 358314 358315 858121 927208 977305 347371 347373 349339 368549 368550 976959 Spinkote Lubricant (2 oz) Tube Removal Tool Beckman Solution 555 (1 qt) Rotor Cleaning Kit Rotor Vise Mounting Tape (replacement) Rotor Cleaning Brush Centri-Tube Slicer CentriTube Slicer Replacement Blades (pkg of 10) Tube Rack, 8 mm Quick-Seal Tube Sealing Rack CentriTube Slicer Adapter for 13mm tubes Quick-Seal Cordless Tube Topper Kit, 60 Hz Quick-Seal Cordless Tube Topper Kit, 50 Hz (Europe) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Great Britain) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Australia) Torque Wrench Hemostat, 6 in. curved Rotor Vise Mounting Screws (pkg of 4) Rotor Plug Gasket Rotor Vise Cap and Plunger Assembly Rotor Plug Replacement (each) Rotor Replacement Plugs with Gaskets (set of 8) Torx Wrench Adapter Adapters/Spacers 361061 1-54 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com TLN-100 TLN-100 8 x 3.9 mL TLN 100 NVT Near-Vertical Rotor, Titanium Axis of Rotation For use in the TL-100, Optima TL, Optima TLX, Optima MAX-XP and Optima MAX-TL ultracentrifuges. rmin (23.1 mm) rav (31.6 mm) rmax (40.2 mm) Note: Non-precipitating solutions up to 1.7 g/mL in density can be run in this rotor without a reduction in rotor speed. Major applications: Plasmid DNA-Separations in 4 hours. 9° Max. RPM Max. g k Factor 100 000 450 000 14 Number of Tubes Volume/Size Rotor Capacity 8 x 3.9 mL 13 x 38 mm 31.2 mL No. 357614. TLN-100 Near-Vertical Rotor Package. Includes Rotor, 1 each 361664 OptiSeal Tube Kit (includes 4 boxes 361627 OptiSeal Tubes, 8 Spacers 362198, 1 Tube Rack 361650, 1 Tube Extraction Tool 361668, and 1 Spacer Removal Tool 338765), 12 each 342882 Rotor Plug Gaskets, 1 each 348122 and 355872 Tube Racks, 347373 Rotor Vise/Stand, 927208 Hemostats, 858121 Torque Wrench, 976959 Torx Wrench Adapter, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. Tubes and Bottles Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Vol. (mL) Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) g-Force 3.3 361627 56 13 x 33 362198 ——— 450 000 14 100 000 3.9 358980 50 13 x 38 342883 ——— 450 000 14 100 000 Rotor Accessories Rotor Replacement Parts 306812 335148 338765 339555 339558 342025 342883 347404 347828 347960 348122 348299 354526 355872 358312 358313 358314 358315 361650 361668 858121 927208 961519 342882 347373 347402 349339 368545 368546 976959 Spinkote Lubricant (2 oz) Silicone Vacuum Grease (1 oz) Tube Removal Tool Beckman Solution 555 (1qt) Rotor Cleaning Kit Fraction Recovery System Quick-Seal Tube Spacer Rotor Cleaning Brush Fraction Recovery System Adapter Kit for TL-series tubes CentriTube Slicer Tube Topper Rack, 13 mm CentriTube Slicer Replacement Blades (pkg of 10) CentriTube Slicer Adapter for 13mm tubes Tube Rack, 13 mm Quick-Seal Cordless Tube Topper Kit, 60 Hz Quick-Seal Cordless Tube Topper Kit, 50 Hz (Europe) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Great Britain) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Australia) OptiSeal Tube Rack Assembly Tube Removal Tool Torque Wrench Hemostat, 6-in curved Hemostat, 6 in. straight k Factor Max. Speed Rotor Plug Gasket Rotor Vise Rotor Vise Mounting Tape (replacement) Cap and Plunger Assembly Rotor Replacement Plug (single) Rotor Replacement Plugs with Gaskets (set of 8) Torx Wrench Adapter Adapters/Spacers 342883 362198 Beckman Coulter Ultracentrifuge 1-55 1 www.beckmancoultercentrifugation.com MLN-80 MLN-80 8 x 8 mL TLN 100 Near-Vertical Tube Rotor, Titanium Axis of Rotation For use in the Optima MAX-XP ultracentrifuge.. Major applications: Rapid contamination-free isopycnic isolation of plasmid DNA. rmin (32.5 mm) rav (43.3 mm) rmax (54.2 mm) 1 Max. RPM Max. g k Factor 80 000 389 000 20 Number of Tubes Volume/Size Rotor Capacity 8 x 8 mL 16 x 58 mm 9° 64 mL No. 367100. MLN-80 Near-Vertical Tube Rotor Package. Includes Rotor, 1 box 344621 Quick-Seal Polyallomer Tubes, 10 each 367101 Spacers, 2 each 392083 Plug and Cell, 349290 Washer and Plug, 1 each 348123 Tube Rack, 347373 Rotor Vise/Stand, 927208 Hemostats, 858121 Torque Wrench, 976959 Torx Wrench Adapter, 338765 Spacer Removal Tool, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. No. 367099. MLN-80 Near-Vertical Tube Rotor Assembly. Tubes and Bottles Tube Style/Material Vol. (mL) Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 1) Required Adapters (qty. 1) g-Force 4.2 356562 50 16 x 38 ——— 389 000 16 80 000 6.3 345830 50 16 x 45 ——— 389 000 18 80 000 8.0 344621 50 16 x 58 349289 367312 349289 367313 367101 ——— 389 000 20 80 000 Quick-Seal Polyallomer Rotor Accessories Rotor Replacement Parts 306812 335148 338765 339379 339555 339558 348123 358312 358313 358314 358315 361668 858121 347373 349290 392083 976959 Spinkote Lubricant (2 oz) Silicone Vacuum Grease (1 oz) Floating Spacer Removal Tool Rotor Cleaning Brush Beckman Solution 555 (1qt) Rotor Cleaning Kit Tube Topper Rack, 16 mm Quick-Seal Cordless Tube Topper Kit, 60 Hz Quick-Seal Cordless Tube Topper Kit, 50 Hz (Europe) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Great Britain) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Australia) Tube Removal Tool Torque Wrench k Factor Max. Speed Rotor Vise Assembly Rotor Plug Gasket Plug, Cell Torx Wrench Adapter Adapters/Spacers 349289 1-56 367101 367312 367313 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com TLS-55 TLS-55 4 x 2.2 mL TLS-55 Swinging-Bucket Rotor, Titanium For use in the TL-100, Optima TL, Optima TLX, Optima MAX-XP and Optima MAX-TL ultracentrifuges. Axis of Rotation rmax (76.5 mm) Note: Non-precipitating solutions up to 1.7 g/mL in density can be run in this rotor without a reduction in rotor speed. rav (59.4 mm) Major applications: RNA pelleting in 2-3 hours; subcellular fractionation in sucrose gradients, protein separations in sucrose gradients. rmin (42.2 mm) Max. RPM Max. g k Factor 55 000 259 000 50 Number of Tubes Volume/Size Rotor Capacity 4 x 2.2 mL 11 x 34 mm 8.8 mL No. 346936. TLS-55 Swinging-Bucket Rotor Assembly with 4 Titanium Buckets. No. 346134. TLS-55 Swinging-Bucket Rotor Package. Includes BioCertified Rotor, 1 box 347357 Polyallomer Tubes, 1 each 348305 Tube Rack, 347358 Bucket Holder Rack, 927208 Hemostats, 868638 O-ring, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. .Tubes and Bottles Tube Style/Material Vol. (mL) Quick-Seal Polyallomer Thinwall Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Thickwall Cellulose Propionate Thickwall Polyethylene Ultra-Clear Part No. Quantity Size (mm) Required Caps/ Spacers (qty. 1) Required Adapters (qty. 4) g-Force 1.5 2.0 175 µL 2.2 1.4 344624 344625 342630 347357 347287 50 50 100 50 100 11 x 25 11 x 32 5 x 20 11 x 34 11 x 34 344674 344674 ——— ——— ——— ——— ——— 358614 ——— ——— 259 000 259 000 248 000 259 000 259 000 37 50 22 50 50 55 000 55 000 55 000 55 000 55 000 230 µL 1.4 230 µL 343775 343778 342303 100 100 100 7 x 20 11 x 34 7 x 20 ——— ——— ——— 358615 ——— 358615 249 000 259 000 249 000 23 50 23 55 000 55 000 55 000 175 µL 343622 100 5 x 20 ——— 358614 248 000 22 55 000 2.2 347356 50 11 x 34 ——— ——— 259 000 50 55 000 Rotor Accessories 306812 335148 338765 339379 339555 339558 347404 347828 347960 348299 348305 349487 358312 358313 358314 358315 361668 Spinkote Lubricant (2 oz) Silicone Vacuum Grease (1 oz) Floating Spacer Removal Tool Rotor Cleaning Brush Beckman Solution 555 (1qt) Rotor Cleaning Kit Rotor Cleaning Brush Fraction Recovery System Adapter Kit for TL-series tubes CentriTube Slicer CentriTube Slicer Replacement Blades (pkg of 10) Tube Rack for 11-mm Tubes (included with Rotor Package) Quick-Seal Tube Rack (Tube Rack Adapters required)√√ Quick-Seal Cordless Tube Topper Kit, 60 Hz Quick-Seal Cordless Tube Topper Kit, 50 Hz (Europe) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Great Britain) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Australia) Quick-Seal Tube Removal Tool k Factor Max. Speed 362100 Tube Rack Adapters, set/8, for 344624 11 x 25 mm Quick-Seal Tubes√√ 362101 Tube Rack Adapters, set/8, for 344625 11 x 25 mm Quick-Seal Tubes√√ 927208 Hemostats, 6-in. curved √ √ Required for obsolete Bench Quick Sealer. Rotor Replacement Parts 345770 345773 346364 347358 349338 868638 Bucket Cap Assembly (each) Rotor Stand Replacement Bucket Set, set of 4 Bucket Holder Rack Cap & Plunger Assembly Bucket O-ring Adapters/Spacers 344674 358614 358615 Beckman Coulter Ultracentrifuge 1-57 1 www.beckmancoultercentrifugation.com MLS-50 4 x 5 mL Swinging-Bucket Rotor, Aluminum For use in the Optima MAX-XP ultracentrifuge. Major applications: Rate-zonal separations of subcellular organelles, pelleting and isopycnic separations of RNA. 1 rmin rav rmax (47.5 mm) (71.7 mm) Max. RPM Max. g k Factor 50 000 268 000 71 Number of Tubes Volume/Size Rotor Capacity 4 x 5 mL 13 x 51 mm (95.8 mm) 20 mL Axis of Rotation No. 367280. MLS-50 Swinging-Bucket Rotor Package. Includes Rotor, 1 box 326819 Polyallomer Tubes, 1 each 331313 Bucket Holder Rack, 927208 Hemostats, 824412 O-ring, 306812 Spinkote Lubricant, and 335148 Vacuum Grease. No. 367279. MLS-50 Swinging-Bucket Rotor Assembly. Tubes Tube Style/Material OptiSeal Polyallomer Quick-Seal Polyallomer Quick-Seal konical Polyallomer Thinwall Polyallomer Thinwall konical Polyallomer Thickwall Polyallomer Thickwall Polycarbonate Ultra-Clear Vol. (mL) Part No. Quantity Size (mm) Floating Spacers (qty. 1) Adapters (qty. 1) g-Force 3.3 361627 56 13 x 33 ——— 268 000 42 50 000 2.0 345829 50 13 x 25 361678 (pkg of 2) 355535 ——— 268 000 29 50 000 3.2 358647 50 13 x 51 355535 358153 (pkg of 6) 262 000 67 50 000 5.0 3.0 326819 358119 50 50 13 x 51 13 x 51 ——— ——— 268 000 262 000 71 67 50 000 50 000 3.5 349623 25 13 x 51 ——— ——— 358153 (pkg of 6) ——— 268 000 71 50 000 3.5 349622 25 13 x 51 ——— ——— 268 000 71 50 000 0.8 5.0 344090 344057 50 50 5 x 41 13 x 51 ——— ——— 356860 ——— 218 000 268 000 67 71 46 000 50 000 Rotor Accessories Rotor Replacement Parts 306812 331313 335148 338765 339379 339555 339558 347828 347960 348122 348299 354468 358312 358313 358314 358315 361638 361668 367278 367284 367285 824412 Spinkote Lubricant (2 oz) Bucket Rack Silicone Vacuum Grease (1 oz) Floating Spacer Removal Tool Rotor Cleaning Brush Beckman Solution 555 (1qt) Rotor Cleaning Kit Fraction Recovery System Adapter Kit for TL-series tubes CentriTube Slicer Tube Topper Rack for 13-mm Tubes CentriTube Slicer Replacement Blades (pkg of 10) Conical Adapter Extractor Tool Quick-Seal Cordless Tube Topper Kit, 60 Hz Quick-Seal Cordless Tube Topper Kit, 50 Hz (Europe) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Great Britain) Quick-Seal Cordless Tube Topper Kit, 50 Hz (Australia) OptiSeal Tube Rack, 13 mm Quick-Seal and OptiSeal Tube Removal Tool k Factor Max. Speed Rotor Stand Assembly Bucket Set Bucket Cap O-ring Adapters/Spacers 355535 1-58 356860 358153 361678 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com A-110 A-110 6 x 180 µL A-110 Fixed-Angle Rotor, Aluminum, Red Axis of Rotation For use in the Airfuge Air-Driven Micro-Ultracentrifuge. Major application: Fast pelleting of very small samples. rmin (9.5 mm) rav (12.1 mm) rmax (14.7 mm) Max. RPM Max. g 110 000 199 000 k Factor 9 Number of Tubes Volume/Size Rotor Capacity 6 x 180 µL 5 x 20 mm 1 080 µL g-Force k Factor Max. Speed 199 000 199 000 199 000 9 9 9 18° No. 347596. A-110 Rotor. Fixed-Angle Rotor with 18° angle, aluminum, anodized red. Includes 1 box of 342630 polyallomer tubes and 1 Tube Rack 348301. Tubes and Bottles Tube Style/Material Usable Volume (µL) Part No. Quantity 175 175 180 342630 343622 344718 100 100 100 Size (mm) Open-Top Tubes Polyallomer Polyethylene Ultra-Clear 5 x 20 5 x 20 5 x 20 110 000 110 000 110 000 Rotor Supplies 339643 348301 343773 339639 341252 341252 Rotor Caps, polyethylene, package of 20 Tube Rack for 5-mm diameter Tubes Tube Cap Strip, 6-place, package of 50 Rotor Base Bushing, white Rotor Stand/Vise Rotor Stand/Vise A-100/30 A-100/30 6 x 240 µL A-100 30 Fixed-Angle Rotor, Aluminum, Blue Axis of Rotation For use in Airfuge Air-Driven Micro-Ultracentrifuge. Major application: Fast pelleting of very small samples. rmin (8.8 mm) rav (13.2 mm) rmax (17.6 mm) Max. RPM Max. g k Factor 92 000 167 000 19 Number of Tubes Volume/Size Rotor Capacity 6 x 240 µL 5 x 20 mm 1 440 µL k Factor Max. Speed 30° No. 347594. A-100/30 Rotor. Fixed-Angle Rotor with 30° angle, anodized blue. Includes 1 box of 342630 Polyallomer Tubes and 1 Tube Rack 348301. Tubes and Bottles Tube Style/Material Usable Volume (µL) Part No. Quantity 220 150 240 342630 343622 344718 100 100 100 Size (mm) g-Force Open-Top Tubes Polyallomer Polyethylene Ultra-Clear 5 x 20 5 x 20 5 x 20 167 000 167 000 167 000 19 19 19 92 000 92 000 92 000 Rotor Supplies 339643 341252 343773 348301 Rotor Caps, polyethylene, package of 20 Rotor Stand/Vise Tube Cap Strip, 6-place, package of 50 Tube Rack for 5-mm diameter Tubes Beckman Coulter Ultracentrifuge 1-59 1 www.beckmancoultercentrifugation.com A-100/18 Fixed-Angle Rotor, Aluminum, Silver Axis of Rotation For use in the Airfuge Air-Driven Micro-Ultracentrifuge. Major application: Fast pelleting of very small samples. rmin (9.5 mm) rav (12.1 mm) rmax (14.7 mm) 1 A-100/18 6 x 175 µL A-100 18 Max. RPM Max. g k Factor 95 000 148 000 12 Number of Tubes Volume/Size Rotor Capacity 6 x 175 µL 5 x 20 mm 1 050 µL k Factor Max. Speed 18° No. 347593. A-100/18 Rotor. Fixed-Angle Rotor with 18° angle, aluminum, anodized silver. Includes 1 box of 342630 Polyallomer Tubes and 1 Tube Rack 348301. Tubes and Bottles Tube Style/Material Usable Volume (µL) Part No. Quantity 175 100 175 342630 343622 344718 100 100 100 Size (mm) g-Force Open-Top Tubes Polyallomer Polyethylene Ultra-Clear 5 x 20 5 x 20 5 x 20 148 000 148 000 148 000 12 12 12 95 000 95 000 95 000 Rotor Supplies 339643 348301 343773 339639 341252 Rotor Caps, polyethylene, package of 20 Tube Rack for 5-mm diameter tubes Tube Cap Strip, 6-place, package of 50 Rotor Base Bushing, white Rotor Stand/Vise A-95 A-95 4 x 450 µL Fixed-Angle Rotor, Aluminum, Black Axis of Rotation For use in Airfuge Air-Driven Micro-Ultracentrifuge. Major application: Fast pelleting of very small samples. rmin (8.9 mm) rav (13.3 mm) rmax (17.6 mm) Max. RPM Max. g k Factor 95 000 178 000 19 30° Number of Tubes Volume/Size Rotor Capacity 4 x 450 µL 8 x 20 mm 1 800 µL k Factor Max. Speed No. 347595. A-95 Rotor. Fixed-Angle Rotor with 30° angle, aluminum, anodized black. Includes 1 box of 345843 Ultra-Clear Tubes and 1 Tube Rack 348302. Tubes and Bottles Tube Style/Material Usable Volume (µL) Part No. Quantity 450 345843 100 Size (mm) g-Force Open-Top Tubes Ultra-Clear 8 x 20 178 000 19 95 000 Rotor Supplies 339643 339639 341252 343773 348302 1-60 Rotor Caps, polyethylene, package of 20 Rotor Base Bushing, white Rotor Stand/Vise Tube Cap Strip, 6-place, package of 50 Tube Rack for 8-mm diameter Tubes Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com ACR-90 ACR-90 3.5 mL/2.4 mL ACR-90 Chylomicron Rotor, Silver For use in the Airfuge Air-Driven Micro-Ultracentrifuge. Major application: Rapid clarification of lipemic blood samples. Max. RPM Max. g k Factor Rotor Capacity Volume/Size Yield (mL) 90,000 90,000 122 000 107 000 45 39 3.5 mL 2.4 mL 2.6 1.4 1 No. 341260. ACR-90 Chylomicron Rotor, anodized aluminum. Consists of a Supporting Base, a Disposable Polyethylene Liner, and Stainless Steel Lid. Includes one 341252 Rotor Stand/Vise, one package 341251 Liners, Adapter for 342635 Liner. Rotor Supplies 306812 339639 341251 341252 342634 Spinkote Lubricant Rotor Bushing, white Liner, polyethylene, 3.5 mL capacity, package of 100 Rotor Stand/Vise Liner, polyethylene, 2.4 mL capacity, package of 100 (Adapter required) 342635 Adapter for 342634 Liners, reusable 343779 Disposable Loading and Unloading Pipette, package of 500 Batch Rotor Batch Rotor 7 mL Batch Rotor, Aluminum, Silver For use in the Airfuge Air-Driven Micro-Ultracentrifuge. Major application: Rapid processing of fruit paste. Max. RPM Max. g Minimum Fill Volume Maximum Fill Volume k Factor 90 000 132 000 2 mL 7 mL 8 at 2 mL 55 at 7 mL No. 347833. Batch Rotor, aluminum, for 2- to 7-mL volumes. Sample is placed in the rotor body itself or in one of two types of polyethylene liners. A plastic window disk is placed between the rotor and the lid to contain samples during centrifugation. Includes 1 each 341252 Rotor Vise/Stand, 853156 O-ring, and 343197 Bushing. Rotor Supplies 341252 Rotor Vise/Stand 343130 Shell Liner, polyethylene, large opening, 7-mL capacity, package of 100 343132 Dome Liner, polyethylene, small opening, 7-mL capacity, package of 100 343197 Bushing, red 347049 Rotor Window Disk 853156 Rotor O-ring Beckman Coulter Ultracentrifuge 1-61 www.beckmancoultercentrifugation.com EM-90 EM-90 6 x 100 µL EM-90 Particle Counting Rotor, Silver For use in the Airfuge Air-Driven Micro-Ultracentrifuge. Major applications: Sedimenting particles onto filter membranes, glass cover slides, and microscope grids. 1 Max. RPM 90 000 Max. g Maximum Volume Rotor Capacity 118 000 6 x 100 µL 600 µL No. 347844. EM-90 Electron Microscopy Particle Counting Rotor. Includes 5-mm Core with 600 µL capacity (100 µL per cell); 3-mm Core with 360 µL capacity (60 µL per cell); one 341252 Rotor Stand/Vise, one 347840 (pkg of 5) Gaskets, Sector Core Removal Bolt, Template, one 853156 O-ring, one 343197 Bushing. Rotor Supplies 343197 347836 347838 347840 Bushing, red Sector Core, 5 mm Sector Core, 3 mm Rotor Gaskets, package of 5 Lid Core Cover Flat Gasket Sector Core (3 mm or 5 mm) Rotor Base Stand 1-62 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Tubes and Bottles Tubes and Bottles For Every Application N 2 o single tube design or material will meet all application requirements. A number of factors should be considered at the time a supply of tubes is ordered: the particular technique to be used, the nature of the sample and any solvent or gradient media, the desirabil ity of reusing the tubes, and certain convenience factors. The properties listed below provide a guide for anyone involved in the tube selection process. • Strength and Flexibility, to resist permanent deformation even whenruninfixedanglerotorswithouttubecaps. • Chemical Resistancetoawiderangeofbases,acids,andsolvents. • Transparency,topermitaclearviewoffractionsandbandsafter centrifugation. • Thinenoughtobeslicedorpuncturedaftercentrifugationfor fractioncollection. • Impermeable to Water,topreventaqueoussolutionsfrom permeatingthetubewallandreachingtherotorcavity. • Surface Propertiesthatpreventtheadherenceofnucleicacids andproteins. • Temperature Tolerancethroughoutawiderangeofoperating temperatures,withoutdeformingathightemperaturesorcracking whenusedcloseto0°C. • Autoclavable,forconvenientsterilizationandreuse. • Contaminant-free,toavoidleachingextraneousmaterialsinto thesample,especiallymaterialsvisibleinthesensitive240-280nmrange. • Odor-free,forpleasanthandling. The full line of Beckman Coulter tubes includes a number of tube materials, each with its own distinct combination of properties, to meet a variety of application requirements. Available are transparent, translucent, and opaque tubes, tubes that can be sliced or punctured, tubes that can be sterilized and reused, and tubes that are resistant to a variety of chemical compounds. Beckman Coulter Ultracentrifuge 2-1 www.beckmancoultercentrifugation.com TubesandBottles Tube Selection Considerations 2 Compatibility of Tube Material with Solvents and Sample Thechemicalcompatibilityofthetubematerialswiththe gradient-formingmediumorothersolventisaprimeconsideration.Neutralsucroseandsaltsolutionscausenoproblem. Butalkalinesolutions,suchasthosefrequentlyusedfor theseparationofsingle-strandedformsofDNA,cannot beusedinUltra-Cleartubesorpolycarbonatetubesand bottles.SometimesDMSOisusedinpreparationofsucrose gradientsforsedimentationofdenaturedRNA.Polycarbonate andUltra-CleartubesareincompatiblewithDMSO,so polyallomertubesshouldbeused. Thelastcolumnofthe“QuickReferenceCharttoTube MaterialsandTheirProperties”onpage2-4givessomeguidelinestothechemicalresistancesofthevarioustubematerials. Itmustbeemphasized,however,thatotherconditionsofcentrifugation(g-force,durationofrun,etc.)haveconsiderable effectonhowwellatubematerialwillwithstandaparticular solvent.BeckmanCoulterpublicationIN-175,“Chemical ResistancesforBeckmanCoulterCentrifugationProducts” (foundontheBeckmanCoulterwebsiteat www.beckmanbuilt.comprovidesmoredetailed informationaboutthechemicalresistancesofthevarious tubematerials.Thewisestcourseistotestanyquestionable combinationunderoperatingconditionsbeforemakingthe actualrun. Thetypeofsample,insomecases,willaffectselectionofa specifictubematerial.DNA,initsdenaturedorsinglestrandedform,willadheretothesurfaceofsometube materials.Polyallomerwouldbethebestchoice.(Mostofthis workisdoneinhighlyalkalinemediawhichareincompatible withpolycarbonate.) LipoproteinseparationsaremostoftendoneinUltra-Clear tubesbecausetheyareclearandsliceable;theseproperties simplifyfractionlocationandrecoverybytubeslicing. Whensmalllipoproteinsamplesaretoberecoveredbya fractionatingdeviceandcleartubesaredesirable,thereare alternatives:cellulosepropionate,polycarbonate,andUltraCleartubes. Hazardousmaterials,eitherpathogenicorradioactive, shouldbecentrifugedwithextremecare.Allpossible precautionsmustbetakentoavoidleakageofthesampleinto therotorcavityduringcentrifugation. Todeterminetheoptimumtubematerialforyourspecific sampleandgradientmedium,refertothequickreference chartonpage2-4. Astherearecurrentlynowettableplasticcentrifugetubes available,gradientsshouldbeloadedintoplastictubesfrom thebottomuptoavoidmixing. High Temperature Centrifugation Althoughmoderncentrifugesandrotorscanoperateat temperaturesashighas45°C,onecannotassumethatevery tubecanbesafelyrunover25°C.Stainlesssteelandglassare theonlymaterialswhichwillnotexperiencesomedeformation whensubjectedtohightemperaturesandlongcentrifugation times.Plastictubesundergosomedegreeofsofteningat temperatureshigherthan25°C.Whetherornotthiswillcause permanentdeformationisnotaquestionoftemperaturealone. Thecentrifugalforcefieldused,thedurationofthecentrifugation,thetypeofrotor,andeventhetubeangleallhavean effect. It’sobviouslyimpossibletogiveexacttemperaturelimits forplastictubeswhensomanyothervariablesareinvolved. Thesafestpolicyistopretestthetubesundertheactual experimentalconditions,butwithwater,ratherthanavaluable sample. Tube Sizes Tubesizesasindicatedinthefollowingchartsarenominal sizes,andmayvarysomewhatfromactualfillingcapacities. Ifathick-walledtubeisrununcapped,themaximumfilling volumewilldependonthetubeangleoftherotortobeused. Seeappropriaterotorinstructionmanualsformaximumfilling levelsoftubes. Tube Cleaning, Sterilization, and Reuse Iftubesaretobereused,specialcaremustbetakenduring cleaningandsterilization.Alltubescanbewashedbyhand withamilddetergentsuchasSolution555diluted5-to-1or 10-to-1withwater.Thisisparticularlyimportantfor polycarbonatetubesandbottleswhichshouldnotbeexposed toadetergentwithapHhigherthan8.Tubesandbottles shouldnotbewashedincommercialdishwashersasthe detergentsandhightemperaturesaretooharsh.Solvents suchasalcoholoracetonereactunfavorablywithmanytube materials.Ifanorganicsolventmustbeusedinthecleaning procedure,consultbulletinIN-175foratableoftubematerial/ solventcompatibilities(orreviewthesamedocumentonthe BeckmanCoulterwebsiteatwww.beckmanbuilt.com. Themethodchosenforsterilizationhasdirectbearingon thenumberofreusesonecanexpectfromatube.Tubesand Gradient Formation and Fractionation bottlesofpolyallomer,polyethylene,andglasscanallbe Whenchoosingatubeforadensitygradientrun,somethought autoclaved,althoughingeneral,coldsterilizationmethodsare shouldbegiventogradientformationandfractionation.Ifthe notasharshasautoclaving.Coldsterilizationisrecommended bandsorzonesformedduringcentrifugationareindistinct, forbothpolycarbonateandUltra-Clear.Donotdrytubes, theymaynotbevisiblethroughatranslucentmaterialsuch bottles,oraccessoriesinanoven.Labwareshouldbeairdried. aspolyallomer.Ifoptimumbandvisualizationisimportant, OptiSeal,Quick-Seal,UltraClear,andthinwallpolyallomer Ultra-Cleartubesortubesofpolycarbonateorcellulose tubesareintendedforone-timeuseandshouldbediscarded propionateshouldbeused.Whenevercollectionofbandsor afteruse. zonesmustbedonebypuncturingthetubeorslicing,athin, Ifmaximumreuseisamajorconsideration,either flexibletubewallisrequired.Ultra-Clearorpolyallomertubes polyallomer(preferablythick-walled)orpolycarbonatetubes shouldbeused,dependingontheneedfortransparency. 2-2 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com TubesandBottles andbottlesshouldbeselected,andcoldsterilizationmethods used.Ifthesetubesareruncompletelyfilledinswinging bucketrotors,mostofthemcanbereusedanumberoftimes. Chancesofpermanentdeformationwillbegreaterwhenever thetubesareruninfixedanglerotors,withoutcaps,and/ orpartiallyfilled.Alloftheseconditionstendtostressthe centripetaledgeofthetubeunduly.Alltubesthathave beenusedorautoclavedpreviouslymustbeindividually examinedforsignsofdeformationorcrackingbeforeusing themagain. Tube Closures Whenotherconsiderationshavebeenresolved, conveniencemaybeadecidingfactor.Withoutadoubt, themostconvenienttubeclosureisnoneatall;noneare requiredfortubesruninswingingbucketrotorsandinthe AirfugeAir-DriveMicro-Ultracentrifuge. Fortubesruninfixedanglerotors,alternativestothe standardtubecapassembliesareavailable.Bottleshave three-piececapassemblieswhichareeasiertousethanthe morecomplextubecapassemblies.Polycarbonatebottles areavailableforgeneral-purposefixedanglerotors,andare usedfrequentlyfordifferentialcentrifugationwhereband recoveryisnotaproblem.Thickwalltubescanberuninall fixedanglerotorswithoutcaps,providedtheyarepartially filled.(Refertorotormanualsformoreinformationon fillvolumes.) Whenclosedtubesarerequired,BeckmanCoulteroffers someinnovativeandconvenient options. OptiSeal Tubes Forvirtuallyeffortlesssealing, OptiSealtubesofferthe bestoption.Yousimply insertthetubeplugand press,andanO-ring sealssecurelyagainst thetube’sinnersurface. Duringcentrifugation,the combinationofg-force andhydrostaticpressure ensuresaneffectiveseal. EngineeredforreliabilCentrifugal ity,therearenotools force ormechanicalpartsto maintain.Fingerpressure isallthatisneeded. Beckman Coulter Ultracentrifuge Hydrostatic pressure Quick-Seal Tubes Thesetubeseliminatemostofthestepsinvolvedin cappingtubesandcuthandlingtimeinhalf.Thetopofthe Quick-Sealtubeiseitherdome-shapedorbell-shapedwitha 3-mm-longinletthroughwhichthetubeisfilled.Thefilled tubeisheat-sealedusing thehand-heldsealer. Thehighlyreliableseal achievedmakesthese Dome-top Tubes tubesidealforsample storageandforworking withradioactiveor pathogenicsamples. Bell-top Tubes There are two Quick-Sealtubedesigns—dome-topandbell-top.Thebelltopsimplifiesremovalofmaterialsthatfloatuponcentrifugation.Thedome-toptubesholdmorevolumethantheir bell-topequivalents. Tube plug is forced into stem by spacer Tube stem elongates due to hydrostatic pressure 2-3 2 www.beckmancoultercentrifugation.com TubesandBottles A Quick-Reference Chart to Tube Materials and Their Properties 2 Property Thinwall Polyallomer Thickwall Polyallomer Ultra-Clear Optical Polycarbonate Polypropylene Polyethylene Cellulose Propionate transparent translucent transparent transparent translucent transparent/translucent transparent Autoclaveable yes yes no no yes no no Puncturable yes no yes no no yes no Sliceable yes no* yes no* no no no* Reusable no yes no yes yes yes no Acids (dilute or weak) S S S S S S S Acids (strong) U S U U S S U U Alcohols (aliphatic) U S U U S S Aldehydes M M S M M S U Bases S S U U S S U Esters U M U U M S M Hydrocarbons (aliphatic) U M U U S U S Hydrocarbons (aromatic and halogenated) U U U U M M S Ketones U M U U M M U Oxidizing Agents (strong) U U U M M M M Salts S S M M S S S S = satisfactory resistance M = marginal resistance U = unsatisfactory resistance Note: This information has been consolidated from a number of sources and is provided only as a guide to the selection of tube materials. Soak tests at 1 g (at 20°C) established the data for most of the materials; reactions may vary under the stress of centrifugation, or with extended contact or temperature variations. To prevent failure and loss of valuable sample, ALWAYS TEST SOLUTIONS UNDER OPERATING CONDITIONS BEFORE USE. * Polyallomer, polycarbonate, and cellulose propionate tubes with diameters of 5 to 13 mm may be sliced using the CentriTube Slicer (part number 347960) and appropriate adapter plate. Warning:Donotuseflammablesubstancesinornearanoperatingcentrifuge. General Filling and Sealing Requirements for Tubes and Bottles Tube or Bottle Swinging-Bucket Rotors Fixed-Angle Rotors Thinwall tubes Within 2 to 3 mm of top Full with cap Thickwall tubes At least 1/2 full 1/2 full to max. capless level or full with cap Quick-Seal tubes Full and heat-sealed Full and heat-sealed Bottles Min. to max. (see rotor manual) with screw-on cap or cap assembly 1/2 full to max. (see rotor manual) with screw-on cap assembly Open-top tubes Within 2 to 3 mm of top Full with cap Quick-Seal tubes Not used Full and heat-sealed Thickwall tubes At least 1/2 full 1/2 full capless level or full with cap or cap assembly Bottles At least 1/2 full Min. to max. (see rotor manual) with screw-on cap or cap assembly Stainless Steel Tubes Any level Any level with cap or cap assembly Polypropylene Tubes and bottles At least 1/2 full 1/2 to max. capless level or full with cap or cap assembly Polyethylene Tubes At least 1/2 full 1/2 to max. capless level or full with cap or cap assembly Teflon Tubes and bottles At least 1/2 full 1/2 full to max. capless level or full with cap Radel Container At least 1/2 full N/A Polyallomer Ultra-Clear Polycarbonate 2-4 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com TubesandBottles Nominal Filling Capacity (mL) Nominal Size (mm) Part No. Rotors See specific rotor pages for required spacers/adapters/accessories OptiSeal Polyallomer Tubes 3.3 13 x 33 361627 SW-55 Ti, SW-50.1, TLN-100, MLS-50 4.7 13 x 48 361621 Types 50.4 Ti, 50.3 Ti, TLA-110, TLA-100.4 4.9 13 x 51 362185 VTi 90, VTi 65.2, NVT 90, NVT 65.2 8.9 16 x 60 361623 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 50, MLA-55 11.2 16 x 70 362181 VTi 65.1, NVT 65 32.4 25 x 77 361625 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, 42.1, 30, SW 32 Ti, SW 28, MLA-50 36.2 25 x 89 362183 VTi 50 8 x 51 345831 Type 25 1.2 8 x 35 361082 TLN-120 1.5 11 x 25 344624 SW 60 Ti, TLA-120.2, TLA-100.2, MLA-130, MLA-150, TLS-55 2.0 11 x 32 344625 SW 60 Ti, TLA-120.2, TLA-100.2, MLA-130, MLA-150, TLS-55 2.0 13 x 25 345829 Types 100 Ti, 50.4 Ti, 50.3, NVT 100, NVT 90, NVT 65.2, VTi 90, VTi 65.2, SW 55 Ti, SW 50, TLA-110, TLA-100.4, TLA-100.3, MLS-50 3.5 13 x 32 349621 Types 100 Ti, TLA-110, TLA-100.3 3.5 14 x 25 355870 SW 41 Ti, SW 40 Ti 3.9 13 x 38 358980 TLN-100 4.2 16 x 32 356562 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 40, SW 30.1, SW 32.1 Ti, SW 28.1, MLA-80, MLN-80, MLA-55 5.1 13 x 51 342412 VTi 90, VTi 65.2, NVT 100, NVT 90, NVT 65.2 5.1 13 x 51 362248 Type 100 Ti, TLA-110 5.9 14 x 47 355537 SW 41 Ti, SW 40 Ti 6.0 13 x 64 344619 Types 100 Ti, 50.4 Ti, 50.3 Ti 6.3 16 x 45 345830 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 50, 40, NVT 65, VTi 65.1,SW 30.1, SW 32.1 Ti, SW 28.1, MLA-80, MLN-80, MLA-55 2 Quick-Seal Polyallomer Tubes 1.0 8.0 16 x 58 344621 Type 50, NVT 65, VTi 65.1, SW 32.1 Ti, SW-28.1, MLA-80, MLN-80 10.0 16 x 67 344622 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti ,40, NVT 65, VTi 65.1, SW 32.1 Ti, SW 28.1, MLA-55 13.5 16 x 76 342413 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti ,40, NVT 65, VTi 65.1, MLA-55 15.0 25 x 38 343664 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, VTi 50, SW 30, SW 32 Ti, SW 28, MLA-50 17.0 16 x 102 356291 SW 32.1 Ti, SW 28.1 27.0 25 x 64 343665 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, 42.1, VTi 50, SW 32 Ti, SW 28, MLA-50 33.0 25 x 83 344623 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, SW 32 Ti, SW 28 39.0 25 x 89 342414 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, VTi 50 100.0 38 x 102 345776 Type 45 Ti Quick-Seal Polyallomer konical Tubes 1.3 11 x 35 358655 SW 60 Ti 3.0 11 x 60 358648 SW 60 Ti 3.2 13 x 51 358647 SW 55 Ti, SW 50.1 Ti, MLS-50 4.0 14 x 48 358650 SW 41 Ti, SW 40 Ti 8.0 14 x 89 358649 SW 41 Ti, SW 40 Ti 8.5 25 x 38 358652 SW 30, SW 32 Ti, SW 28 12.5 16 x 102 358653 SW 32.1 Ti, SW 28.1 23.0 25 x 76 358654 SW 32 Ti, SW 28 28.0 25 x 83 358651 SW 32 Ti, SW 32 Ti, SW 28 Quick-Seal Ultra-Clear Tubes 5.1 13 x 51 344075 NVT 90, NVT 65.2, VTi 90, VTi 65.2 6.0 13 x 64 344320 Types 50.4 Ti, 50.3 Ti 13.5 16 x 76 344322 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 40, NVT 65, VTi 65.1, MLA-55 Beckman Coulter Ultracentrifuge 2-5 www.beckmancoultercentrifugation.com TubesandBottles Nominal Filling Capacity (mL) Nominal Size (mm) Part No. Rotors See specific rotor pages for required spacers/adapters/accessories 25 x 38 25 x 64 25 x 89 38 x 102 344324 344323 344326 345778 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, VTi 50, MLA-50 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, VTi 50, MLA-50 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, VTi 50 Type 45 Ti 175 µL 450 µL 0.8 2.0 2.2 3.0 4.0 4.0 5.0 6.5 5 x 20 8 x 20 5 x 41 8 x 49 11 x 34 13 x 32 11 x 60 13 x 41 13 x 51 13 x 64 344718 345843 344090 344091 347356 344092 344062 344093 344057 344088 10.0 10.5 13.2 13.5 16 x 64 13 x 89 14 x 89 16 x 76 344089 344087 344059 344085 14.0 17.0 38.5 94.0 14 x 95 16 x 102 25 x 89 38 x 102 344060 344061 344058 345777 A-110, A-100/30, A-100/18 A-95 SW 55 Ti, SW 50.1, MLS-50 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 50.4 Ti, 50.3 Ti, 50, 40, MLA-55 TLS-55 Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 50, 40, MLA-55 SW 60 Ti Types 90 Ti, 80 Ti, 70.1 Ti, 65, 50 Ti, 50, 40, MLA-55 SW 55 Ti, SW 50.1, MLS-50 Types 90 Ti, 80 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.4 Ti, 50.3 Ti, 50.2 Ti, 50 Ti, 45 Ti, 40.3, 40.2, 40, 21, MLA-55 Type 50 Types 45 Ti, 21 SW 41 Ti Types 90 Ti, 80 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.2 Ti, 50 Ti, 45 Ti, 40, 21, MLA-55 SW 40 Ti SW 32.1 Ti, SW 28.1 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, SW 32 Ti, SW 28 Types 45 Ti, 21 Quick-Seal Ultra-Clear Tubes (cont’d) 15.0 27.0 39.0 100.0 2 Ultra-Clear Tubes Thinwall Polyallomer Tubes 175 µL 2.2 4.0 5.0 6.5 11 x 34 11 x 60 13 x 51 13 x 64 5 x 20 342630 347357 328874 326819 326820 10.5 13.2 13.5 13 x 89 14 x 89 16 x 76 326822 331372 326814 14.0 17.0 35.5 38.5 94.0 14 x 95 16 x 102 25 x 83 25 x 89 38 x 102 331374 337986 344367 326823 345775 TLS-55, A-110, A-100/30, A-100/18 TLS-55 SW 60 Ti SW 55 Ti, SW 50.1, MLS-50 Types 90 Ti, 80 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.4 Ti, 50.3 Ti, 50.2 Ti, 50 Ti, 45 Ti, 40, 40.3, 40.2, 21, MLA-55, MLA-50 Types 45 Ti, 21 SW 41 Ti Types 90 Ti, 80 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.2 Ti, 50 Ti, 45 Ti, 40, 30, 21, MLA-55, MLA-50 SW 40 Ti SW 32.1 Ti, SW 28.1 Type 70 Ti Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, SW 32 Ti, SW 28 Types 45 Ti, 21 358117 358118 358119 358120 358121 358123 358125 358126 SW 60 Ti SW 60 Ti SW 55 Ti, SW 50.1 Ti, MLS-50 SW 41 Ti, SW 40 Ti SW 40 Ti SW 32.1 Ti, SW 28.1 SW 32 Ti, SW 28 SW 32 Ti, SW 28 Thinwall Polyallomer, konical Tubes 1.5 3.0 3.0 10.0 11.0 14.5 25.0 30.0 2-6 11 x 35 11 x 60 13 x 51 14 x 89 14 x 95 16 x 102 25 x 76 25 x 89 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com TubesandBottles Nominal Filling Capacity (mL) Nominal Size (mm) Part No. Rotors See specific rotor pages for required spacers/adapters/accessories Thickwall Polyallomer Tubes 230 µL 7 x 20 343621 Type 42.2 Ti, TLA-100 .5 8 x 34 343777 TLA-120.1, TLA-100.1 1.0 11 x 34 347287 TLA-120.2, TLA-100.2, MLA-130, MLA-150, TLS-55 3.0 11 x 60 355636 SW 60 Ti 3.2 13 x 56 362333 TLA-110, TLA-100.4 3.5 13 x 51 349623 SW 55 Ti, SW 50.1, TLA-100.3, MLS-50 4.0 13 x 64 355644 Types 90 Ti, 80 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.4 Ti, 50.3 Ti, 50.2 Ti, 50 Ti, 45 Ti, 40, 21, MLA-55, MLA-50 6.5 16 x 64 355646 Type 50, MLA-80 10.0 16 x 76 355640 Types 90 Ti, 80 Ti, 75 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.2 Ti, 50 Ti,45 Ti, 42.1, 40, 35, 30, 21, SW 25.1, MLA-55, MLA-50 10.5 13 x 89 355639 Types 45 Ti, 21 32.0 25 x 89 355642 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, SW 32 Ti, SW 28 94.0 38 x 102 355643 Types 45 Ti, 21 Thickwall Polycarbonate Tubes 230 µL 7 x 20 343775 Type 42.2 Ti, TLA-100, TLS-55 .5 8 x 34 343776 TLA-120.1, TLA-100.1 1.0 8 x 51 355657 Types 50.4 Ti, 25 1.0 11 x 34 343778 TLA-120.2, TLA-100.2, MLA-130, MLA-150, TLS-55 3.0 11 x 60 355635 SW 60 Ti 3.2 13 x 56 362305 TLA-110, TLA-100.4 3.5 13 x 51 349622 SW 55 Ti, SW 50.1, TLA-100.3, MLS-50 4.0 13 x 64 355645 Types 90 Ti, 80 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.4 Ti, 50.3 Ti, 50.2 Ti, 50 Ti, 45 Ti, 40, 21, MLA-55, MLA-50 6.5 16 x 64 355647 Type 50, MLA-80 10.0 16 x 76 355630 Types 90 Ti, 80 Ti, 75 Ti, 70.1 Ti, 70 Ti, 65, 60 Ti, 55.2 Ti, 50.2 Ti, 50 Ti, 45 Ti, 40, 21, MLA-55, MLA-50 10.5 13 x 89 355629 Types 45 Ti, 21 32.0 25 x 89 355631 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, SW 32 Ti, SW 28 94.0 38 x 102 355628 Types 45 Ti, 21 7 x 20 342303 Type 42.2 Ti 38.5 25 x 89 301112 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, 42.1, 94.0 38 x 102 303380 Types 45 Ti, 21 5 x 20 343622 TLS-55, A-110, A-100/30, A-100/18 Cellulose Propionate Tubes 230 µL Stainless Steel Tubes Polyethylene Tubes 175 µL Polyallomer Tubes with Snap-on Caps 1.5 11 x 40 Beckman Coulter Ultracentrifuge 357448 (Natural) TLA-110, TLA-100.4, TLA-100.3, TLA-55, TLA-45 2-7 2 www.beckmancoultercentrifugation.com BottleAssemblieswithThree-PieceCaps Nominal Filling Capacity (mL) Nominal Size (mm) Bottle & Cap Assembly Bottle Only Cap Assembly Cap Only Plug Only O-ring Only Rotors Bottle and Cap Assembly 2 PC — 8.5 16 x 64 355615 355656 355604 335257 335256 870409 Type 50 PC — 10.4 16 x 76 355603 355651 355604 335257 335256 870409 Types 90 Ti, 80 Ti, 75 Ti, 70.1 Ti, 65, 50 Ti, 40, MLA-55 PC — 26.3 25 x 89 3556161 355654 355617 335259 335258 870385 Type 30 PC — 26.3 25 x 89 3556181 355654 355619 338824 335258 870385 Types 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, 42.1 PC — 70.0 38 x 102 3556202 355655 355621 334547 334545 870384 Types 35, 21 PC — 70.0 38 x 102 3556222 355655 355623 339165 334545 870384 Type 45 Ti PA —250.0 60 x 120 334205 355627 362247 362246 332836 812715 Type 19 PP —250.0 62 x 122 356011 358326 358977 357490 N/A 927860 Type 16 PC —250.0 62 x 122 356013 358275 358977 357490 N/A 927860 Type 16 1 2 Note: Regarding packaging, bottle and cap assemblies are packaged in units of 6, with the following exceptions: Bottle and Cap assembly 334205 is packaged as one; Bottles 355656 and 355651 are packaged in units of 25; Cap assembly 334543 is packaged as one. Caps, Plugs, and Orings are packaged separately. The only difference between these two assemblies is the cap which is Noryl in the 355616 assembly and aluminum in the 355618 assembly. The Noryl cap can be used in the Type 30 Rotor. The only difference between these two assemblies is the cap which is Noryl in the 355620 assembly and aluminum in the 355622 assembly. The Noryl cap can be used in the Type 35 and 21 Rotors; the aluminum cap is required for the higher speed forces of the Type 45 Ti. 2-8 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com TubesandBottles Tube Cap Assemblies and Parts Cap Material Tube Cap Hex Nut Crown Set Screw Insert O-ring or Gasket Stem Set Screw 5⁄16 Al Al 1⁄2 303624 303658 303379 303379 303809 303810 ——— ——— ——— ——— 303730 303730 303377 303377 303113 346256 305022 301870 301870 301870 307004 307004 307004 ——— 803543 301870 301870 301870 335320 307006 330774 338911 335319 338864 803543 338864 338864 ——— 302312 344672 344672 344672 307005 346246 302331 301869 858046 878572 858046 302266 330788 338910 341969 in. (16 mm) Al Al Al Ti 303319 330860 338907 341968 302312 302312 302312 302312 1 in. (25 mm) Al Al Al Al/Ti Al Al 302359 302133 331151 337927 338901 338906 2 Hex Nut Washer in. (13 mm) Al Al Al/SS 5⁄8 Insert in. (8mm) Crown O-ring or Gasket Stem Tube 301870 301870 330791 330791 330791 330791 302169 302169 331153* 338863* 338912* 338915* 338864 338864 338864 338864 338864 338864 302312 302312 302312 302312 302312 302312 301473 301473 334280 ——— 878188 878188 302168 302138 331152 338865 338908 338908 301870 301870 330791 330791 330791 326890 326890 330793* 338914* 338913* 808482 338864 338864 338864 338864 302312 302312 302312 302312 302312 346242 801761 346242 341767 341767 326889 326899 330900 338909 338909 11⁄2 in. (38 mm) Al Al Al Al Al 326891 326905 330901 338903 338905 * Also order 330899 Washer. Beckman Coulter Ultracentrifuge 2-9 www.beckmancoultercentrifugation.com Tools, Accessories, and Supplies S ample preparation and recovery are important steps in the centrifugation process. To help in these often time-consuming steps, Beckman Coulter provides a number of tools and accessories for use in preparing your samples for centrifugation as well as for recovering the particles of interest when your separation is complete. Everything you need can be conveniently ordered from 3 the following listings. Beckman Coulter Ultracentrifuge 3-1 www.beckmancoultercentrifugation.com Tools and Supplies Required Tools If you’re running capped tubes in the following rotors: Types 90 Ti, 75 Ti, 70.1 Ti, 70 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, 50 Ti, 45 Ti, 42.1, 35, or MLA-55, you’ll need the following tools. Tools also needed for Types 30 and 21 rotors if capped thickwall tubes are used. 331202 Tool Kit 305075 Cap Vise If you’re running 337927 caps in the Type 70 Ti rotor, you’ll need: 338841 Tool Kit If you’re running Quick-Seal tubes, you’ll need: 358312 358313 358314 358315 Tube Topper Kit, 60 Hz (U.S./Canada/Japan) Tube Topper Kit, 50 Hz (for Europe) Tube Topper Kit, 50 Hz (for Great Britain) Tube Topper Kit, 50 Hz (for Australia) Note: F orfurtherinformation,refertothespecifictechnicalbulletinfromthe Technical Publications Department. 305075 Cap Vise Tools for Fixed-Angle Rotors (see also Tools for Quick-Seal Tubes) 301875 Removal Tool, for capped tubes 841884 Hex Driver, for 5⁄16-in. (8 mm) hex nuts 302460 Nylon Insert Tool, for cap stem filling hole 858122 Socket Adapter, for 858123 Socket below 305075 Tube-Cap Vise 858123 Socket, for tightening red, blue, and black aluminum caps, 3⁄4-in. (19 mm) hex nut 841883 Hex Driver, for 7⁄16-in. (11 mm) hex nuts 870432 Socket, for tightening titanium caps (cap 341968), 7⁄16-in. (11 mm) hex nut 3 3-2 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Tools and Supplies Tools for Fixed-Angle Rotors (cont.) 878133 Removal Tool, for polycarbonate bottles with aluminum caps 331325 Centering Tool, for replacing overspeed disk 338841 Tool Kit, for Type 70 Ti Rotor when 344367 Tubes and 337927 Caps are used. Includes the following: 335381 Removal Tool, for polycarbonate bottles with Noryl caps 301875 338835 338840 858121 858122 858123 870432 Removal Tool, for capped tubes Tube Cap Vise Tube Cap Assembler Torque Wrench Socket Adapter Socket, for 3⁄4 -in. (19 mm) hex nut Socket, for 7⁄16 -in. (11 mm) hex nut 331202 Tool Kit for capped thin-wall and thick-wall tubes when used in Types 90 Ti, 75 Ti, 70.1 Ti, 60 Ti, 55.2 Ti, 50.2 Ti, 50 Ti, 45 Ti, 42.1, 35, and MLA-55 Rotors. Also needed for Types 30 and 21 Rotors if capped thickwall tubes are used. Includes the following: 301875 858121 858122 858123 870432 3 303419 Removal Tool, for Delrin tube adapters (not for use with adapters for konical Tubes) Removal Tool, for capped tubes Torque Wrench Socket Adapter Socket, for 3⁄4 -in. (19 mm) hex nut Socket, for 7⁄16 -in. (11 mm) hex nut Beckman Coulter Ultracentrifuge 3-3 www.beckmancoultercentrifugation.com Tools and Supplies Tools for Vertical-Tube and NVT Rotors (See also Tools for Quick-Seal Tubes) Note: V Ti65,VTi65.1andVTi50rotorsmanufacturedpriorto8/87wereequippedwithpin-styleandsquare-styleplugs,andrequirespecifictoolsmentionedinthebottomof this section. To update these rotors, purchase a full set of the new hex-style plugs and the appropriate tools. 332688 Rotor Vise, for VTi 65 and VTi 50 rotors 342705 Rotor Vise, for VTi 90, NVT 100*, NVT 90, NVT-65, VTi 65.1, VTi 65.2, and VAC 50 rotors * 355588 Hex Plug-wrench Adapter for VTi 50, VC 53, VAC 50 Rotors 356306 Hex Plug-wrench Adapter for VTi 90, VTi 65, VTi 65.1, VTi 65.2, and MLN-80 Rotors 3 889096 Torque Wrench, 600 in.-lb., forVTi 50, VC 53, VAC 50 Rotors 858121 Torque Wrench, 200 in.-lb. for VTi 90, VTi 65, VTi 65.1, VTi 65.2, NVT 100, NVT 90, NVT 65.2, VTi 80, TLN-120, TLN-100, and TLN-80 Rotors Requires adapter 367084. Tools for VTi 65, VTI 65.1 and VTi 50 Manufactured before 8/87 340632 Four-hole Plug-wrench Adapter for VTi 50 Rotors 345795 Two-hole Plug-wrench Adapter for VTi 65 Rotors 347372 Hex Plug Adapter for TLN-120, TLN-100, TLV-100 347373 Rotor Vise for TLN-120, TLN-100, TLV-100, TLN-80, MLA-55 889096 Torque Wrench for VTi 50, VC 50, VAC 50 976959 Torx Wrench Adapter for NVT 100, NVT 90, NVT 65.2, VTi 90, VTi 65.2, TLV-100, TLN-120 Reminder: These items are supplied with the Rotor Package; order only as replacements. Tools for Swinging-Bucket Rotors 001878 Bucket Cap Tool, for SW 60 Ti Rotor 354468 332400 927208 330070 Removal Tool, for konical Tube Adapters Rotor Stand Hemostat (6-in., curved) Hinge Pin Tool, for SW 65 Ti, SW 41 Ti and SW 40 Ti Rotors Reminder: These items are supplied with the Rotor Package; order only as replacements. Tools for Zonal Rotors (See also Tools for Quick-Seal Tubes) 001884 332618 332848 819247 3-4 Hex Wrench, 5⁄64-in. (1.9 mm), for Support Band Seal Disassembly Tool Locating Spacer, for Ti-15, A1-15, Ti-14 Rotors Lubriplate Grease, 13⁄4-oz. Tube 328917 Tool Kit, for Zonal Rotors. Includes the following: 332688 Rotor Vise 332690 Spanner Wrench 333763 Tubing Removal Tool 858532 Pliers Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Tools and Supplies Supplies 306812 Spinkote Lubricant, 2-oz. tube 335148 Vacuum Grease, 1-oz. jar 339379 Brush, for cleaning rotor cavities, 7⁄16 in. to 1 in. (11 to 25 mm) in diameter; minimum order of three. 339380 Brush, for cleaning rotor cavities, 1 in. to 11⁄2 in. (25 to 38 mm) in diameter; minimum order of three. 339555 Rotor Cleaning Concentrate, Solution 555, 946-mL bottle; minimum order of two 339558 Rotor Cleaning Kit (see description on page 2–18) includes: one 339379 Brush, one 339380 Brush and two bottles of 339555 Rotor Cleaning Concentrate 347404 Brush, for cleaning rotor cavities, 1⁄4 in. to 1⁄2 in. (6 to 13 mm) in diameter; minimum order of three. 339587 Master Rotor Logbook 330049 Logbook, for Preparative Ultracentrifuge Instruments 339648 Rotor Record Cards, package of five pads 3 Tools for Quick-Seal Tubes 338765 Removal Tool, for Floating Spacers (except when used in Swinging Bucket Rotors) 354468 Removal Tool, for konical Tube Adapters used in Swinging Bucket Rotors 348120 Seal Formers (round-topped) for use with Tube Topper 345395 Ultra-Clear Tube Sealing Oil, 7.5 mL bottle 361668 Removal Tool for Tubes and Spacers (and Floating Spacers in Swinging Bucket Rotors) 342415 Funnel Beckman Coulter Ultracentrifuge 3-5 www.beckmancoultercentrifugation.com Tools and Supplies Quick-Seal Tube Racks For Cordless Tube Topper These autoclavable racks accommodate Quick-Seal Tubes for use with the Cordless Tube Topper. 348122 348123 348124 348125 349387 349661 356568 Tube Rack (Red), for 1⁄2-in. (13 mm) diameter Tubes Tube Rack (Green), for 5⁄8-in. (16 mm) diameter Tubes Tube Rack (Blue), for 1-in. (25 mm) diameter Tubes Tube Rack (Black), for 11⁄2 -in. (38 mm) diameter Tubes Tube Rack (Gold), for 7⁄16-in. (11 mm) diameter Tubes Tube Rack (Orange), for 5⁄16-in. (8 mm) diameter Tubes Tube Rack (Violet), for 9⁄16-in. (14 mm) diameter Tubes 3 Tools for OptiSeal Tubes For easy handling of OptiSeal Tubes, specially designed Tube Racks and Removal Tools are available. 338765 360538 360542 361638 361642 Removal Tool, for 5⁄8-in Floating Spacer (362202) OptiSeal Tube Rack, for 5⁄8 x 23⁄4-in. (16 x 70 mm) Tubes OptiSeal Tube Rack, for 1 x 31⁄2-in. (25 x 89 mm) Tubes OptiSeal Tube Rack, for 1⁄2 x 17⁄8-in. (13 x 48 mm) Tubes OptiSeal Tube Rack, for 5⁄8 x 23⁄8-in. (16 x 60 mm) Bell top Tubes 361646 OptiSeal Tube Rack, for 1 x 31⁄4-in. (25 x 77 mm) Bell top Tubes 361650 OptiSeal Tube Rack, for 1⁄2 x 115⁄16-in. (13 x 33 mm) Tubes 361668 OptiSeal Tube Extraction Tool 3-6 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Tools and Supplies Cordless Tube Topper 358312 358313 358314 358315 Tube Topper Kit, 60 Hz (U.S./Canada/Japan) Tube Topper Kit, 50 Hz (for Europe) Tube Topper Kit, 50 Hz (for Great Britain) Tube Topper Kit, 50 Hz (for Australia) Each Kit Contains: 1 each 348117 Heatsink, 2 each 348643 Seal Guide, 8 each 348120 Seal Former (domed top), 1 each Tube Topper and Charging Unit, 1 each 361668 Tube Extractor. Replacement Parts 338765 342415 348117 348120 348643 357442 358317 889676 927937 961601 974874 Removal Tool for Plastic Spacers and Floating Spacers Funnels (two) Heat Sink Seal Former (domed top) for Tube Topper Seal Guide Flat-top Seal Former for Tube Sealer Tip Plastic Box for holding Accessories Battery Lamp (screw-type socket) Lamp (bayonet-type socket) Beckman Coulter Ultracentrifuge 3 3-7 www.beckmancoultercentrifugation.com Accessories Tube Slicer — for Preparative Ultracentrifuge Tubes 303811 Tube Slicer Kit, contains parts listed below. (Note: Vise not included.) Replacement Parts 303830 303838 303917 303918 303919 303920 303921 303922 303923 303924 332692 332693 338516 338517 829623 3 Blade Assembly Blade Rubber Ring, 1-in. (25 mm), two required Rubber Ring, 5⁄8 -in. (16 mm), two required Rubber Ring, 1⁄2 -in. (13 mm), two required Rubber Ring, 5⁄16 -in. (8 mm), two required Metal Shim Ring, 1-in. (25 mm), two required Metal Shim Ring, 5⁄8 -in. (16 mm), two required Metal Shim Ring, 7⁄16 -in. (13 mm), two required Metal Shim Ring, 5⁄16 -in. (8 mm), two required Metal Shim Ring, 9⁄16 -in. (14 mm), two required Rubber Ring, 9⁄16 -in. (14 mm), two required Rubber Ring, 7⁄16 -in. (11 mm), two required Metal Shim Ring, 7⁄16 -in. (11 mm), two required Thumbscrew CentriTube Slicer — for Micro Ultracentrifuge Tubes 347960 CentriTube Slicer Kit. Includes Adapter Plates, Blades, Storage Box, Hardware Kit, Spinkote Lubricant, and Instruction Manual. Replacement Parts 306812 Spinkote Lubricant 348299 Blades, coated package of 10 348307 Replacement Hardware Kit (3 thumbscrews, 1 set of blade clips) 354443 Adapter Plate, 13 mm diameter 354444 Adapter Plate, 11 mm diameter 354445 Adapter Plate, 8 mm diameter 354446 Adapter Plate, 7 mm diameter 354471 Blades, uncoated, package of 10 889676 Plastic Storage Box 3-8 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Accessories Rotor Cleaning Kit 339558 Rotor Cleaning Kit. Contains two 946-mL bottles of Solution 555 Rotor Cleaning Concentrate, 339379 Rotor Cleaning Brush, and 339380 Rotor Cleaning Brush Replacement Parts/Supplies 339379 Rotor Cleaning Brush, 5⁄8-in. (16 mm) and 1-in. (25.4 mm), for Rotor Cavity diameters from 7⁄16-in. (11 mm) to 1-in. (25.4 mm) (min. order three Brushes) 339380 Rotor Cleaning Brush, 11⁄4-in. (32 mm) and 11⁄2-in. (38 mm), for Rotor Cavity diameters from 1-in. (25.4 mm) to 11⁄2-in. (38 mm) (min. order three Brushes) 339555 Solution 555 Rotor Cleaning Concentrate (min. order two Bottles) 3 Beckman Coulter Ultracentrifuge 3-9 www.beckmancoultercentrifugation.com Accessories Fraction Recovery System HOLLOW-CONE CAP ASSEMBLY Lock-ring Collar 339194 Spring 878224 Plug 331593 Thumbscrew Drain Tube 331598 Hollow-cone Plug Cap 331593 3 Swivel Fitting 313336 Bushing 331594 O-ring 807475 Upper Mount 343787 O-ring 863590 Gasket FLAT-CONE CAP ASSEMBLY Flat-bottomed Cap 339192 Tube Support Shaft* Tube Mounting Pad 343785 Plug 885086 Guide Post 343781 Lower Mount Thumbscrew 343795 Swivel Fitting 313336 Gasket 339191 Teflon Tubing Needle Assembly 343786 Seal, Cushion 331601 Ringstand Two types of systems are available: one with a flatbottomed cap, and those with hollow-cone caps. Using the flat-bottomed cap, sample is removed through a puncture hole in the bottom of the tube. This cap fits any tube diameter and must be used to fractionate QuickSeal tubes. The four hollow-cone cap systems are used for sample recovery from tubes that cannot be punctured or for recovery from the tops or bottoms of puncturable tubes. Each hollow-cone system is for a single tube diameter. System Part Numbers 342023 Fraction Recovery System with Hollow-cone Cap for 1⁄2 -in. Tubes. 342024 Fraction Recovery System with Hollow-cone Cap for 5⁄8 -in. Tubes. 342025 Fraction Recovery System with Hollow-cone Cap for 7⁄16 -in. Tubes. 342026 Fraction Recovery System with Hollow-cone Cap for 1-in. Tubes. 343890 Fraction Recovery System with flat-bottomed Cap for puncturing all Tubes, including Quick-Seal Tubes*. Hollow-Cone Caps 331562 331563 331564 331565 331566 331586 331587 331588 331589 331591 334310 334312 Hollow-cone Cap for 1-in. diameter Tubes Hollow-cone Cap for 11⁄4 -in. diameter Tubes Hollow-cone Cap for 5⁄8 -in. diameter Tubes Hollow-cone Cap for 1⁄2 -in. diameter Tubes Hollow-cone Cap for 9⁄16 -in. diameter Tubes Gasket for 331566 Cap Gasket for 331565 Cap Gasket for 331564 Cap Gasket for 331563 Cap Gasket for 331562 Cap Hollow-cone Cap for 7⁄16 -in. diameter Tubes Gasket for 334310 Cap Replacement Parts for Discontinued 339187 Universal Fraction Recovery System 331584 Piercing Screw 343786 Needle Assembly 343804 Retrofit Kit, includes lower mount (shown left) for lever puncturing to 343890 819838 Setscrew with plastic tip * 346105 Tube Support Shaft, 2-in., 346106 Tube Support Shaft, 3-in., both included in 343890. 3-10 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Reference Guide to Centrifuge Selection Centrifugation is a basic separation technique that is utilized at multiple stages in the study of sample components. Flexible rotor and adapter systems for Beckman Coulter centrifuges allow them to be used across multiple application areas. To help you select the most appropriate centrifuge for your work, the following charts provide brief descriptions of the kinds of separations typically achieved using various centrifuges. These charts list frequent separation requirements for each sample type and identify the centrifuges that are typically used to meet those requirements. In addition to the separation and isolation of sample particles, centrifugation is increasingly being used as an analytical technique for the study of macromolecular interactions and the determination of molecular weights. Instruments for these applications are also listed below. Quick-Reference Guide to Centrifuge Selection Avanti Series Microfuge Allegra Series J6 Series Centrifuges Typically Used Optima MAX Series Airfuge Specific Application Optima X Series Materials to be Isolated Preparative Centrifugation Ammonium sulfate precipitates Sucrose/glycerol gradient isolation Centrifugal filtration • Fractionation by flotation Density gradient fractionation Fractionation by precipitation Chylomicron removal • Sucrose gradient isolation • • Pelleting Sucrose gradient isolation Microsomal membrane fractionation • • • • Mitochondria Pelleting Sucrose gradient isolation • • Nuclei Pelleting • • Membranes Pelleting Sucrose/Percoll gradient fractionation Binding studies • • • • • • Ribosomes/Polysomes Pelleting Size fractionation in sucrose gradients • • • Cytosol Clarification • • • Proteins 4 Lipoproteins Subcellular Fraction Chromatin/Nucleosomes Microsomes 4-2 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Reference Quick-Reference Guide to Centrifuge Selection (cont.) Specific Application Optima X Series Optima MAX Series Airfuge J6 Series Allegra Series Microfuge Avanti Series Materials to be Isolated Preparative Centrifugation Lysates/Homogenates • • Clearing debris and large particles • • • • Nucleic Acids DNA RNA Cells Viruses • Alcohol precipitation Phenol/CHC13 extraction Plasmid purification in CsCl Size fractionation in sucrose gradients Minipreps in 96-well plates Spin columns • • • • • • • • • • • • • • • • • • Isolation of mononuclear cells on Ficoll-Hypaque Pelleting bacteria Pelleting mammalian cells Elutriation of viable cells Other density gradient separations Beckman Coulter Ultracentrifuge • • Phenol/CHC13 extraction Alcohol precipitation Lithium precipitation Pelleting in CsCl CSTFA density gradient Pelleting PEG precipitates Density gradient isolations • • • • • • • • • • • • • • • • • 4 • • 4-3 www.beckmancoultercentrifugation.com Reference How to Choose a Rotor When choosing a rotor, there are several factors to consider: your sample volume and number of individual samples; the number of components in each sample; the level of purity your research requires; and how quickly you wish to achieve the separation. The Importance of k Factor Obviously, separation is affected by maximum speed and maximum radius which together determine maximum g-force. However, particle pathlength also affects separation time. A simple measure of overall rotor efficiency which incorporates both g-force and particle pathlength is the k Factor. Generally speaking, the lower the k Factor, the shorter the run time. This makes the k Factor one of the most important considerations when selecting a rotor. The chart on 4-5 compares k Factors among the four basic rotor types. (Refer to page 4-12 for useful formulas relating to k Factors.) 4 Rotor Material Beckman Coulter ultracentrifuge rotors are made of either aluminum, or titanium. • Aluminum rotors are relatively light and easy to handle, but less durable and slightly more susceptible to corrosion than titanium rotors. Beckman Coulter still offers some aluminum rotors for customers who own older ultracentrifuges, the primary instruments for which these rotors were originally designed. • Titanium rotors are generally stronger and more resistant to corrosion, making them the logical choice for rapid separation at high speeds or when corrosive chemicals will be used. Vertical-Tube (VT) Rotors These rotors are often used for isopycnic and rate zonal separations when run-time reduction is important. Since vertical tube rotors hold sample tubes parallel to the axis of rotation, particle pathlengths are limited to the diameter of the tube — a short pathlength that results in fast run times. NVT Near-Vertical Tube Rotors NVT Near-Vertical Tube Rotors, a patented Beckman Coulter innovation, were designed specifically for density gradient separations. Their narrow angle of less than 10° is calculated using a proprietary algorithm which determines the optimal angle for each rotor, taking into consideration specific tube geometries. These angles result in significantly reduced run times compared with conventional Fixed-Angle Rotors, while positioning pelleted and floated components at the ends of the tubes, away from the bands of interest. Continuous-Flow/Zonal Rotors These rotors are capable of processing large sample volumes in their cores. This large-scale processing ability is clearly evident in Continuous-Flow Rotors, which can process a typical 10-liter sample in about four hours, instead of the 12-24 hours required by conventional methods. Zonal Rotors have similar utility in large-scale density gradient separations. Swinging-Bucket (SW) Rotors Generally used when maximum resolution of sample zones is needed, as in rate zonal studies. Because tubes are held in a horizontal position while spinning, the pathlength is the full length of the tube, which results in longer run times than with other rotor types. These long run times are offset by excellent resolution of sample bands in rate zonal separations. Swinging-Bucket Rotors are also the best choice when a compact pellet is needed, as when pelleting RNA through a cesium chloride cushion. Fixed-Angle (FA) Rotors These rotors provide faster run times than SW rotors at the expense of some resolution in rate zonal studies. They are most useful for pelleting and for isopycnic banding of DNA, where a shallow density gradient and reorientation combine to increase both the width of sample bands and the distance between them, making band extraction easier. 4-4 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Reference Particle Separation in Swinging-Bucket, Fixed-Angle, Near-Vertical Tube, and Vertical-Tube Rotors At Speed in Rotor At Rest in Rotor At Rest Outside Rotor Swinging-Bucket Rotors Typical Example: SW 60 Ti Pathlength: 57.2 mm k Factor: 45 rmin rmax Pathlength Fixed-Angle Rotors Typical Example: Type 90 Ti Pathlength: 42.3 mm k Factor: 25 rmax rmin Pathlength 4 Near-Vertical Tube Rotors Typical Example: NVT 90 Pathlength: 18.7 mm k Factor: 10 rmin rmax Pathlength Vertical-Tube Rotors Typical Example: VTi 90 Pathlength: 13.2 mm k Factor: 6 rmin rmax Pathlength Dark orange represents pelleted material, light orange depicts floating components, and bands are indicated by black lines. Beckman Coulter Ultracentrifuge 4-5 www.beckmancoultercentrifugation.com n n n n n n n n n Largest Volume n Largest Number of Samples n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n Fastest Pelleting n n n n n Largest Volume Rate-Zonal Separation Fastest Rate-Zonal Separation Separation of Viruses and Viral Particles n n n n n Fastest Rate-Zonal Separation n n n Fastest Separation n n n n n Largest Volume for Pelleting n n n n n n n n n n n n n n n n n n n n n n n n Largest Number for Differential Flotation n n n n Ti-15 VTi 50 VTi 65.2 VTi 65.1 VTi 90 NVT 65.2 NVT 90 NVT 65 n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n Largest Volume n n n Greatest Interband Space Fastest Separation n n n Largest Volume for Differential Flotation Isopycnic Separation of Plasmid DNA n n n n Fastest Differential Flotation Fastest Separation n n Greatest Interband Distance Pelleting RNA Through a CsCI Gradient n n n Largest Volume Largest Number of Samples Separation of Lipoproteins n n Largest Volume Rate-Zonal Separation Rate-Zonal Separation of Proteins in Sucrose Gradient n n n Fastest Pelleting n n TLS-55 Largest Volume for Pelleting n n n MLA-50 Separation of Subcellular Particles TLA-55 Specific Application MLA-55 Bioseparation n MLA-80 Tabletop Ultracentrifuge Rotor Selection by Application* n TLA-100 n TLA-100.3 n TLA-110 n TLA-120.1 n TLA-120.2 n MLA-130 n MLA-150 4 Largest Volume NVT 100 SW 28 n Fastest Separation n n n Fastest Separation Greatest Interband Distance n n n Fastest Density Gradient Separation n n n Greatest Interband Space Isopycnic Separation of Plasmid DNA n n n Pelleting RNA Through a Largest Volume CsCl Gradient n n n n n n Largest Number for Differential Flotation Largest Volume for Differential Flotation n n n n Greatest Interband Distance n n n n n MLN-80 Separation of Lipoproteins Fastest Differential Flotation n n n TLN-100 Fastest Separation n n Fastest Rate-Zonal Separation Rate-Zonal Separation of Proteins in Sucrose Gradient n n TLN-120 Largest Volume for Pelleting Separation of Virus and Largest Volume Rate-Zonal Separation Viral Particles SW 28.1 n n MLS-50 Fastest Rate-Zonal Separation SW 32 Ti SW 32.1 Ti SW 40 Ti SW 41 Ti SW 55 Ti SW 60 Ti n Largest Volume Rate-Zonal Separation CF-32 Ti n Type 19 n Type 25 n Type 45 Ti Type 50.2 Ti n Type 42.2 Ti Type 70 Ti n Largest Volume for Pelleting Type 50.4 Ti Type 70.1 Ti Separation of Subcellular Particles Type 90 Ti Floor Model Ultracentrifuge Rotor Selection by Application* Type 100 Ti Reference n n n n n n n n n n n n n n n n n n n n n n n n Greatest Interband Distance n n n n Largest Volume n n n n n n n n n n n n n n n n n n n *Selected rotor has the capability (RCF, volume, labware) to accommodate the application, but may not be the most optimal/efficient choice for the specific application. 4-6 Beckman Coulter Ultracentrifuge n www.beckmancoultercentrifugation.com Reference Gradient Materials There is no ideal all-purpose gradient material. Sucrose is used for most rate separations and cesium chloride is often used for isopycnic separations. The basic requirement is that the gradient permits the desired type of separation. Additional considerations in selecting a gradient material include the following: • Its density range should be sufficient to permit separation of the particles of interest by the chosen density gradient technique, without overstressing the rotor. • It should not affect the biological activity of the sample. • It should be neither hyperosmotic nor hypoosmotic when the sample is composed of sensitive organelles. • It should not interfere with the assay technique. • It should be removable from the purified product. • It should not absorb in the ultraviolet or visible range. • It should be inexpensive and readily available; more expensive materials should be recoverable for reuse. 4 • It should be sterilizable. • It should not be corrosive to the rotor, particularly for zonal or continuous-flow operation. • It should not be flammable or toxic to the extent that its aerosols could be hazardous. The following tables are provided as a reference for information on commonly used gradient materials. Beckman Coulter Ultracentrifuge 4-7 www.beckmancoultercentrifugation.com Reference Commonly Used Gradient Materials with Their Solvents Materials Solvent Maximum Density at 20°C Sucrose (66%) Sucrose (65%) Silica sols Diodon Glycerol H2O D2O H2O H2O H2O 1.32 1.37 1.30 1.37 1.26 Cesium chloride H2O D2O H2O H2O H2O H2O 1.91 1.98 2.10 2.00 1.49 1.85 Lithium bromide H2O H2O H2O D2O H2O D2O H2O 1.63 1.41 1.57 1.63 1.32 1.40 1.83 Lithium chloride Albumin Sorbitol Ficoll Metrizamide D2O H2O H2O H2O H2O 1.33 1.35 1.39 1.17 1.46 Cesium formate Cesium acetate Rubidium chloride Rubidium formate Rubidium bromide Potassium acetate Potassium formate Sodium formate 4 4-8 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Reference Density, Refractive Index, and Concentration Data—Cesium Chloride at 25°C Molecular Weight = 168.37 Density (g/cm3)* Refractive Index, ηD % by Weight mg/ml of Solution** Molarity Density (g/cm3)* Refractive Index, ηD % by Weight mg/ml of Solution** Molarity 1.0047 1.0125 1.0204 1.0284 1.0365 1.3333 1.3340 1.3348 1.3356 1.3364 1 2 3 4 5 10.0 20.2 30.6 41.1 51.8 0.056 0.119 0.182 0.244 0.308 1.336 1.3496 1.363 1.377 1.391 1.3657 1.3670 1.3683 1.3696 1.3709 34 35 36 37 38 454.2 472.4 490.7 509.5 528.6 2.698 2.806 2.914 3.026 3.140 1.0447 1.0531 1.0615 1.0700 1.0788 1.3372 1.3380 1.3388 1.3397 1.3405 6 7 8 9 10 62.8 73.7 84.9 96.3 107.9 0.373 0.438 0.504 0.572 0.641 1.406 1.4196 1.435 1.450 1.465 1.3722 1.3735 1.3750 1.3764 1.3778 39 40 41 42 43 548.3 567.8 588.4 609.0 630.0 3.257 3.372 3.495 3.617 3.742 1.0877 1.0967 1.1059 1.1151 1.1245 1.3414 1.3423 1.3432 1.3441 1.3450 11 12 13 14 15 119.6 131.6 143.8 156.1 168.7 0.710 0.782 0.854 0.927 1.002 1.481 1.4969 1.513 1.529 1.546 1.3792 1.3807 1.3822 1.3837 1.3852 44 45 46 47 48 651.6 673.6 696.0 718.6 742.1 3.870 4.001 4.134 4.268 4.408 1.1340 1.1437 1.1536 1.1637 1.1739 1.3459 1.3468 1.3478 1.3488 1.3498 16 17 18 19 20 181.4 194.4 207.6 221.1 234.8 1.077 1.155 1.233 1.313 1.395 1.564 1.5825 1.601 1.619 1.638 1.3868 1.3885 1.3903 1.3920 1.3937 49 50 51 52 53 766.4 791.3 816.5 841.9 868.1 4.552 4.700 4.849 5.000 5.156 1.1843 1.1948 1.2055 1.2164 1.2275 1.3508 1.3518 1.3529 1.3539 1.3550 21 22 23 24 25 248.7 262.9 277.3 291.9 306.9 1.477 1.561 1.647 1.734 1.823 1.658 1.6778 1.699 1.720 1.741 1.3955 1.3973 1.3992 1.4012 1.4032 54 55 56 57 58 895.3 922.8 951.4 980.4 1009.8 5.317 5.481 5.651 5.823 5.998 1.2387 1.2502 1.2619 1.2738 1.2858 1.3561 1.3572 1.3584 1.3596 1.3607 26 27 28 29 30 322.1 337.6 353.3 369.4 385.7 1.913 2.005 2.098 2.194 2.291 1.763 1.7846 1.808 1.831 1.856 1.4052 1.4072 1.4093 1.4115 1.4137 59 60 61 62 63 1040.2 1070.8 1102.9 1135.8 1167.3 6.178 6.360 6.550 6.746 6.945 1.298 1.311 1.324 1.3619 1.3631 1.3644 31 32 33 402.4 419.5 436.9 2.390 2.492 2.595 1.880 1.9052 1.4160 1.4183 64 65 1203.2 1238.4 7.146 7.355 4 Density data are from International Critical Tables. ** Computed from the relationship p25 = 10.2402 hD25—12.6483 for densities between 1.00 and 1.38, and p25 = /0.8601 hD25—13.4974 for densities above 1.37 (Bruner and Vinograd, 1965). ** Divide by 10.0 to obtain % w/v. Beckman Coulter Ultracentrifuge 4-9 www.beckmancoultercentrifugation.com Reference Density, Refractive Index, and Concentration Data – Sucrose at 20°C, Molecular Weight = 342.3 4 Density (g/cm3) Refractive Index, ηD % by Weight mg/ml of Solution* Molarity Density (g/cm3) Refractive Index, ηD % by Weight mg/ml of Solution* Molarity 0.9982 1.0021 1.0060 1.0099 1.0139 1.3330 1.3344 1.3359 1.3374 1.3388 0 1 2 3 4 10.0 20.1 30.3 40.6 0.029 0.059 0.089 0.119 1.1463 1.1513 1.1562 1.1612 1.1663 1.3883 1.3902 1.3920 1.3939 1.3958 34 35 36 37 38 389.7 403.0 416.2 429.6 443.2 1.138 1.177 1.216 1.255 1.295 1.0179 1.0219 1.0259 1.0299 1.0340 1.3403 1.3418 1.3433 1.3448 1.3464 5 6 7 8 9 50.9 61.3 71.8 82.4 93.1 0.149 0.179 0.210 0.211 0.272 1.1713 1.1764 1.1816 1.1868 1.1920 1.3978 1.3997 1.4016 1.4036 1.4056 39 40 41 42 43 456.8 470.6 484.5 498.5 512.6 1.334 1.375 1.415 1.456 1.498 1.0381 1.0423 1.0465 1.0507 1.0549 1.3479 1.3494 1.3510 1.3526 1.3541 10 11 12 13 14 103.8 114.7 125.6 136.6 147.7 0.303 0.335 0.367 0.399 0.431 1.1972 1.2025 1.2079 1.2132 1.2186 1.4076 1.4096 1.4117 1.4137 1.4158 44 45 46 47 48 526.8 541.1 555.6 570.2 584.9 1.539 1.581 1.623 1.666 1.709 1.0592 1.0635 1.0678 1.0721 1.0765 1.3557 1.3573 1.3590 1.3606 1.3622 15 16 17 18 19 158.9 170.2 181.5 193.0 204.5 0.464 0.497 0.530 0.564 0.597 1.2241 1.2296 1.2351 1.2406 1.2462 1.4179 1.4200 1.4221 1.4242 1.4264 49 50 51 52 53 599.8 614.8 629.9 645.1 660.5 1.752 1.796 1.840 1.885 1.930 1.0810 1.0854 1.0899 1.0944 1.0990 1.3639 1.3655 1.3672 1.3689 1.3706 20 21 22 23 24 216.2 227.9 239.8 251.7 263.8 0.632 0.666 0.701 0.735 0.771 1.2519 1.2575 1.2632 1.2690 1.2748 1.4285 1.5307 1.4329 1.4351 1.4373 54 55 56 57 58 676.0 691.6 707.4 723.3 739.4 1.975 2.020 2.067 2.113 2.160 1.1036 1.1082 1.1128 1.1175 1.1222 1.3723 1.3740 1.3758 1.3775 1.3793 25 26 27 28 29 275.9 288.1 300.5 312.9 325.4 0.806 0.842 0.878 0.914 0.951 1.2806 1.2865 1.2924 1.2983 1.3043 1.4396 1.4418 1.4441 1.4464 1.4486 59 60 61 62 63 755.6 771.9 788.3 804.9 821.7 2.207 2.255 2.303 2.351 2.401 1.1270 1.1318 1.1366 1.1415 1.3811 1.3829 1.3847 1.3865 30 31 32 33 338.1 350.9 363.7 376.7 0.988 1.025 1.063 1.100 1.3103 1.3163 1.3224 1.3286 1.4509 1.4532 1.4558 1.4581 64 65 66 67 838.6 855.6 872.8 890.2 2.450 2.500 2.550 2.864 Density and refractive index data are from the International Critical Tables. ** Divide by 10.0 to obtain % w/v. 4-10 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Reference Density Conversion for Cesium and Rubidium Salts at 20°C Sucrose at 20°C, Molecular Weight = 342 .3 % w/w CsCl CsBr Csl Cs2SO4 CsNO3 RbCl RbBr Rbl Rb2SO4 RbNO3 1 2 4 6 8 1.00593 1.01374 1.02969 1.04609 1.06297 1.00612 1.01412 1.03048 1.04734 1.06472 1.00608 1.01402 1.03029 1.04707 1.06438 1.0061 1.0144 1.0316 1.0494 1.0676 1.00566 1.01319 1.02859 1.04443 1.06072 1.00561 1.01307 1.02825 1.04379 1.05917 1.00593 1.01372 1.02965 1.04604 1.06291 1.00591 1.01370 1.02963 1.04604 1.06296 1.0066 1.0150 1.0322 1.0499 1.0680 1.0053 1.0125 1.0272 1.0422 1.0575 10 12 14 16 18 1.08036 1.09828 1.11676 1.13582 1.15549 1.08265 1.10116 1.12029 1.14007 1.16053 1.08225 1.10071 1.11979 1.13953 1.15996 1.0870 1.1071 1.1275 1.1484 1.1696 1.07745 1.09463 1.11227 1.07604 1.09281 1.11004 1.12775 1.14596 1.08028 1.09817 1.11661 1.13563 1.15526 1.08041 1.09842 1.11701 1.13621 1.15605 1.0864 1.1052 1.1246 1.1446 1.1652 1.0731 1.0892 1.1057 1.1227 1.1401 20 22 24 26 28 1.17580 1.19679 1.21849 1.24093 1.26414 1.18107 1.20362 1.22634 1.24990 1.27435 1.18112 1.20305 1.22580 1.24942 1.27395 1.1913 1.2137 1.2375 1.2643 1.16469 1.18396 1.20379 1.22421 1.24524 1.17554 1.19650 1.21817 1.24059 1.26380 1.17657 1.19781 1.21980 1.24257 1.26616 1.1864 1.2083 1.2309 1.2542 1.2782 1.1580 1.1763 1.1952 1.2146 1.2346 30 35 40 45 50 1.28817 1.35218 1.42245 1.49993 1.58575 1.29973 1.36764 1.44275 1.52626 1.61970 1.29944 1.36776 1.44354 1.52803 1.62278 1.26691 1.32407 1.38599 1.45330 1.52675 1.28784 1.35191 1.42233 1.50010 1.58639 1.29061 1.35598 1.42806 1.50792 1.59691 1.3028 1.3281 1.2552 1.2764 55 60 65 1.68137 1.78859 1.90966 1.72492 1.68254 1.69667 1.80924 1 93722 Beckman Coulter Ultracentrifuge 4 4-11 www.beckmancoultercentrifugation.com Reference Useful Formulas k Factor To determine k Factor To determine pelleting time (t) k= t= To relate pelleting time between rotors To adjust k Factor for runs less than maximum rotor speed ln (rmax/rmin) ω2 k s × 10-13 3600 OR k = 2.53 × 105 ln (rmax/rmin) (rpm/1000)2 where s = sedimentation coefficient in Svedbergs k k1 = t2 t1 2 kadj = k rated speed of rotor (maximum ) actual run speed 2 To relate relative centrifugal force (RCF) to speed (rpm): RCFmax = 1.12 rmax 4 rpm ( 1000 ) 2 OR rpm = 103 RCF 1.12 rmax To relate the sedimentation coefficient (s) to rotational speed: s= Svedberg unit (S) equivalent: 1 dr × ω2r dt S = 10-13 seconds Reduced run speed for dense solutions: reduced run speed = max rated speed of rotor × A/B where A = max. permissible density of rotor tube contents, and B = actual density of the tubes to be centrifuged 4-12 Beckman Coulter Ultracentrifuge www.beckmancoultercentrifugation.com Support Services 5 Beckman Coulter Ultracentrifuge 5-1 www.beckmancoultercentrifugation.com Support Services Field Service Support Most of us appreciate the need for careful design, handling, and maintenance of certain kinds of laboratory equipment— the optics of a spectrophotometer, for example. It may not be obvious, however, that anything as substantial looking as a centrifuge rotor must be properly maintained during use in order for it to fulfill its life expectancy. If you consider that, during rotation, an Ultracentrifuge Rotor may experience more than 1,000,000 times the force of gravity, it becomes apparent that seemingly minor flaws will assume much greater significance at these g-forces. In effect, one gram will “weigh” 1,000 kilograms, and a tiny flaw in a critical part may generate stresses greater than the rotor was designed to withstand. We at Beckman Coulter maintain stringent quality standards and rigorously test every rotor design. Specific instructions for care and maintenance are included in the rotor manual that accompanies each rotor. And our Field Rotor Inspection Program is available at no charge to all users of Beckman Coulter Ultracentrifuges and High-Speed Centrifuges. 5 Field Rotor Inspection Program. What Is It? Our Field Rotor Inspection Program (FRIP) has two purposes: to prevent premature rotor failures by detection of stress corrosion, metal fatigue, wear or damage to anodized coatings; and to instruct laboratory personnel in the proper care of rotors. Contact your local Beckman Coulter Service Office for details on the Field Rotor Inspection Program. Using nondestructive methods (fiber optics borescopy and dyepenetrant analysis), they may find signs of corrosion or other damage. If so, they will recommend repair or replacement, and a potentially costly failure may be prevented. To give a fuller understanding of rotors, a comprehensive slide presentation is also offered. Centrifuge users are informed about maintenance procedures, rotor damage, and its significance. The stress corrosion of aluminum rotors, in particular, can be greatly reduced by good laboratory practice. For more information about the Field Rotor Inspection Program (FRIP), please go to: www.beckmanbuilt.com. Sometimes rotor corrosion is so bad it can be seen by the naked eye, while at other times it is not so apparent. If you have doubt about the condition of a single Beckman Coulter 5-2 rotor, you may return it to the factory where it will be inspected free of charge by our metallurgists. The rotor will be examined by a variety of nondestructive methods, including ultrasound which is capable of detecting internal flaws. Before shipping the rotor, you must contact the nearest Beckman Coulter Sales and Service office for specific instructions. A written statement must accompany each rotor, indicating that it is safe to handle, (i.e. free of any pathogenic or radioactive contamination). Rotor Safety Seminars To help you get the most from your Beckman Coulter rotors, Rotor Safety Seminars are frequently presented by our Field Service engineers. Seminars are designed to remind centrifuge users about the importance of proper rotor care and maintenance. When you attend a Beckman Coulter Rotor Safety Seminar, you will have an opportunity to ask questions that are specific to your particular situation, and you will learn: • What causes corrosion in a rotor, where it starts, what it does to the rotor, and how to avoid it. • The proper way to clean and store rotors. • How to get longer life from your rotor. On-Site Rotor Inspection and Maintenance Specially trained Beckman Coulter Field Service engineers are available at your request for on-site inspection and minor rotor maintenance. Rotors that are free of biological and radiological contamination can be brought to these sessions for immediate inspection so you can continue operating your centrifuge with confidence in the condition of your rotors. A Comprehensive Approach to Centrifuge System Care Throughout the world, Beckman Coulter Field Service engineers are on hand to provide the support you need. So you can operate your centrifuges worry-free, a number of programs are in place that cover preventive maintenance of your system, including parts, labor, drive systems, and rotors. It all adds up to a comprehensive approach to maximizing your system investment. Contact your local Beckman Coulter Sales and Service office to find out the specifics about the program available in your area. Beckman Coulter Ultracentrifuge HIGH-PERFORMANCE & HIGH-CAPACITY CENTRIFUGES INGENUITY MEETS PRACTICALITY. www.beckmancoultercentrifugation.com S ince the introduction of the first commercial Rotors with the BioCertified symbol and have been ultracentrifuge in 1947 — the classic Beckman tested to demonstrate containment of aerosols under normal Model L — Beckman Coulter has been at the operating conditions of the associated Beckman Coulter forefront of centrifuge innovation. Although the physics of this basic separation technique never change, Beckman centrifuge when used and maintained as instructed. Following the centrifuge descriptions, listings of their Coulter continually designs new and innovative rotors and rotors are included with information on speed and g-force accessories, and develops advanced methods that allow capability. Also included is information on tubes and bottles the forces of centrifugation to be applied in new ways. that can be used and the adapters they require. This centrifuge product selection guide is designed Tubes and bottles are cross-referenced in a separate to help you determine the most efficient centrifuge tools section that provides details on tube materials, chemical for your laboratory. compatibility, tube designs, and tube closure options. Each section begins with a brief description of instruments A reference section at the back of the guide includes that Beckman Coulter offers within that centrifuge category. quick-reference charts on instrument and tube selection, as Because biocontainment is a major concern in today’s well as frequently used formulas. laboratories, Beckman Coulter provides a number of options that address this issue. Special BioSafe instruments and accessories are available across our centrifuge product line and are identified with these icons: BioSafe and BioSafety are terms intended to describe the enhanced biocontainment features of our products. BioCertified is a term used to describe our products which have been tested and validated to demonstrate containment of microbiological aerosols by an independent, third-party facility (Health Protection Agency, Porton Down, UK or USAMRIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and, thus, containment. BioEnhanced is a term intended to describe our products' enhanced level of biocontainment by design. Beckman Coulter High Performance Centrifuges i www.beckmancoultercentrifugation.com Table of Contents High Performance and High Capacity Centrifugation High Performance Centrifuges Avanti J-26S High Performance Centrifuges......................................................................................................................... 1-2 Avanti JXN-26 High Performance Centrifuge....................................................................................................................... 1-4 Avanti J-E High Performance Centrifuge .............................................................................................................................. 1-6 Avanti J-30I High Performance Centrifuge ........................................................................................................................... 1-7 High Capacity Centrifuges J6-MI High Capacity Centrifuge ........................................................................................................................................... 1-8 Avanti J-HC Centrifuge ......................................................................................................................................................... 1-9 Tubes and Bottles Tubes and Bottles for Every Application ...................................................................................................................................... 2-1 Tube Selection Considerations Compatibility of Tube Material with Solvents and Samples ................................................................................................. 2-2 Gradient Formation and Fractionation................................................................................................................................... 2-2 High Temperature Centrifugation .......................................................................................................................................... 2-2 Tube Sizes ..................................................................................................................................................................................... 2-2 Tube Cleaning, Sterilization and Reuse ........................................................................................................................................ 2-2 Tube Closures ............................................................................................................................................................................... 2-3 A Quick Reference Chart to Tube Materials and Their Properties ............................................................................................... 2-3 General Filling and Sealing Requirements ................................................................................................................................... 2-4 High Performance and High Capacity Bottles .............................................................................................................................. 2-5 Adapters for Non-Beckman Coulter Tubes/Bottles ...................................................................................................................... 2-6 Adapters and Sleeves for Glass Tubes in Beckman Coulter High Performance Rotors ............................................................... 2-6 Tubes and Bottles (Listed by Volume) .......................................................................................................................................... 2-7 HarvestLine System Liners ......................................................................................................................................................... 2-10 Tools and Supplies .......................................................................................................................................................................2-11 Reference Guide to Centrifuge Selection....................................................................................................................................................... 3-2 Useful Formulas ............................................................................................................................................................................ 3-4 Support Services Field Rotor Inspection Program and On-Site Support .................................................................................................................. 4-2 Beckman Coulter High Performance Centrifuges iii High-Performance & High-Capacity Centrifugation The power to accomplish more. In the footsteps of our founder, Arnold O. Beckman, Ph.D., we at Beckman Coulter remain dedicated to your resourcefulness. In fact, we help create the world’s most productive and efficient laboratories by providing the finest centrifuges available. And with our high-performance and high-capacity solutions, we’ve set an all-new standard for enhanced power, speed and flexibility. As a result, you can achieve more throughput and greater control over your lab’s workflow. Beckman Coulter has earned the sobriquet of gold standard from our customers around the globe. And the quality built into our high-performance and high-capacity centrifuges is a shining example of just how far innovation can lead. www.beckmancoultercentrifugation.com High Performance and High Capacity Centrifugation High Performance Centrifuges Avanti JXN-26 High Performance Centrifuge..............1-2 Avanti J-26S High Performance Centrifuges................1-4 Avanti J-E High Performance Centrifuge .....................1-6 Avanti J-30I High Performance Centrifuge ..................1-7 High Capacity Centrifuges J6-MI High Capacity Centrifuge ..................................1-8 Avanti J-HC Centrifuge ................................................1-9 High Performance Centrifuge/Rotor Compatibility Chart .1-10 High Performance and High Capacity Rotor Summary ....1-12 Rotor Selection by Application ..........................................1-15 Beckman Coulter High Performance Centrifuges 1 Fixed-Angle Rotors JA-30.50 Ti .................................................................1-16 JA-25.50......................................................................1-17 JA-25.15......................................................................1-18 JA-21...........................................................................1-19 JA-20.1........................................................................1-20 JA-20...........................................................................1-21 JA-18.1........................................................................1-22 JA-18...........................................................................1-23 JA-17...........................................................................1-24 J-LITE JLA-16.250.....................................................1-25 JA-14.50......................................................................1-26 JA-14...........................................................................1-27 JA-12...........................................................................1-28 J-LITE JLA-10.500 .....................................................1-29 JA-10...........................................................................1-30 J-LITE JLA-9.1000 .....................................................1-31 J-LITE JLA-8.1000.....................................................1-33 Swinging Bucket Rotors JS-24.38 ......................................................................1-35 JS-24.15 ......................................................................1-36 JS-13.1 ........................................................................1-37 JS-7.5 ..........................................................................1-38 JS-5.9 ..........................................................................1-40 JS-5.3 ..........................................................................1-41 JS-5.2 ..........................................................................1-43 JS-5.0 ..........................................................................1-46 JS-4.3 ..........................................................................1-47 JS-4.2 ..........................................................................1-50 JS-4.2A........................................................................1-52 JS-4.2SM .....................................................................1-54 JS-4.2SMA..................................................................1-55 JS-4.0 ..........................................................................1-56 JS-3.0 ..........................................................................1-59 Zonal and Continuous Flow Rotors JCF-Z ..........................................................................1-62 Elutriation Rotors JE-5.0 ..........................................................................1-64 1-1 www.beckmancoultercentrifugation.com High Performance Centrifugation 1 Avanti JXN-26 High Performance Centrifuge The versatility you need. The performance you expect. The Avanti JXN-26 is a refrigerated centrifuge that generates centrifugal forces required for a wide variety of applications. It achieves up to 26,000 rpm/81,770 x g. The Avanti JXN-26 centrifuge design features a brushless switchedreluctance drive motor,* an automatic rotor identification system, FRS (friction reduction system), vacuum control circuitry, temperature control system, programmable acceleration and deceleration profiles, and a touch screen interface which shows both the information display and the control input for the instrument. The JXN-26 includes many options for configuring your system such as: managing your network, users, rotors and reports. 1 Ergonomic design • Low work surface height for easier installation and unloading of rotors 5 • On-screen text sensitive “help” screen • Foot pedal for hands-free door operation 2 • Up to 1000 user-defined programs • Door swings up and out of the way for easy access to the rotor chamber • Set up and store numerous protocols • Large digital readouts make operations simpler • Network multiple instruments • Password protection for up to 50 unique user profiles • Data logging and real-time run graphing Gain flexibility with MobileFuge • Set and monitor run parameters and email diagnostic results • Control and monitor the centrifuge from your Apple® iOS and Android™ device with MobileFuge • Get alerts and diagnostics remotely 3 Advanced, easy-to-use data management • Perfect for shared labs or GMP environments Intuitive interface • User-friendly, large LCD screen • View set and actual run conditions simultaneously 6 Versatile across rotors and applications • Compatible with an extensive library of rotors • Fixed-angle and swinging bucket options available • Fully compatible with lightweight J-Lite rotors • Dynamic Rotor Inertia Check (DRIC) and rotor recognition provide redundant safety checks to assure no rotor can be run above its rated speed • Temperature control is optimized ensuring sample quality and avoiding unwanted artifacts • Select rotor by name, not by arcane number code • 11 accel/12 decel rates • Delay start • Run times to 99:59, Hold, and Ω 2t integrator for applications that require exquisite reproducibility 4 Safe and sustainable • Friction Reduction System (FRS) allows quicker, quieter, and cooler runs • Uses less energy than traditional centrifuges • BioSafe† options • Dynamic rotor inertia check • High-torque, Switched Reluctance (SR) drive cycle shortens cycle times * SR drives are manufactured by Beckman Coulter, Inc. with technology licensed from Switched Reluctance Drives Limited. † BioSafe is a term intended to describe the enhanced biocontainment features of our products. 1-2 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com High Performance Centrifugation Specifications Avanti JXN-26 Maximum Speed/g-Force 26,000 rpm / 81,770 x g Maximum Capacity 6 Liters Speed Control 1 Low Speed ± 10 rpm of set speed High Speed ± 0.1% rpm of set speed Set Temperature –10°C to 40°C in 1° increments a Temperature Control ± 2°C of chamber temperature after equilibration Ambient Operating Range 16°C to 38°C b Accel / Decel Profiles 11 / 12 5,120 BTU/hr (1.5 kW)c Heat Output Drive Type / Cooling SR* drive / Air-cooled Refrigeration Refrigerant 404A (HVC) Sound Level 57 dBAd Dimensions (with door closed) 71 W x 86 D x 86 H cm (28 W x 34 D x 34 H in) Weight 290 kg (640 lbs) HEPA Filter Pharmaceutical-grade sterilizing filter system a: Proprietary algorithm applied to provide an estimated sample temperature. b: To reach temperatures above ambient, the centrifuge is dependent on the frictional heat generated inside the chamber during operation. At low run speeds or low ambient temperatures, the centrifuge may not be able to achieve some higher temperatures. c: JA-20 rotor running at 20,000 rpm at 4°C. d: JA-30.50 Ti rotor with chamber precooled and running at 26,000 rpm. * SR drives are manufactured by Beckman Coulter, Inc. with technology licensed from Switched Reluctance Drives Limited. Part Numbers** 230 V, 50 Hz, 24A 200–240 V, 50/60 Hz, 24A 220 V, 3-Phase, 50 Hz, 12A Avanti JXN-26 IVD B38623 B38619 B38618 Avanti JXN-26 Non-IVD B37912 B34183 B34182 Model Any unit can be made BioSafe† with addition of HEPA filter kit: B37916 HEPA filter kit for Avanti JXN-26 (external mount) **Availability varies by geography. Contact your local sales representative to determine the correct part numbers for ordering. † BioSafe is a term intended to describe the enhanced biocontainment features of our products. Beckman Coulter High Performance Centrifuges 1-3 www.beckmancoultercentrifugation.com High Performance Centrifugation 1 Avanti J-26S XP Series High Performance Centrifuge Bringing benchmark performance higher. Already a leader in high performance, the Avanti J-26S has been redesigned to provide even more versatility and safety. Above and beyond its existing complete BioSafety § systems, the Avanti J-26S has a more impact-resistant lid, full containment barrier, and automatic rotor identification. But improvements aren’t the only features that set the Avanti J-26S apart. It’s built upon standard-setting performance, including high speed, low heat output, imbalance tolerance and low noise. Its vast range of separations only continues to grow. And its ergonomic design—with lower instrument height and hands-free door operation—remains unchanged. 1 2 3 3 5 Complete BioSafety§ systems BioCertified rotors, instruments and labware contain microbiological aerosols, while sterile filters prevent infectious materials from being expelled into the lab environment. Together, they enhance peace of mind for users and lab managers. ¥ Dual system rotor recognition Automatically detects which rotor is installed and prevents the rotor from running above its maximumrated speed—without shutting down the run. All to ensure the safety of your lab. 1-4 4 High performance Application versatility: can process six liters of fermentor output in less than 10 minutes, deliver a subcellular fraction at 82,000 x g, run 24 microplates at a time, and separate live cell populations with elutriation. Friction Reduction System Enables quicker, quieter, more energy-efficient runs with better temperature control, which improves system reliability. High-torque, switched reluctance (SR) drive technology shortens cycle times. Lightweight J-Lite rotors Consistently designed to be the most efficient rotors—for reduced run times and high g-force. 2 4 6 5 7 6 1 7 Ergonomic design Lower work surface for easier rotor handling. Foot pedal opens the door and improved door design swings up and out of the way. Sustainability is built in Each J-26S centrifuge will contain approximately 7.5 pounds of recycled PET bottles. Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com High Performance Centrifugation Specifications Avanti J-26S XP Maximum speed/g-Force 26,000 rpm / 81,800 x g Maximum Capacity 6 Liters Speed Control 1 Low Speed ± 10 rpm of set speed High Speed ± 0.1% rpm of set speed Set Temperature –10°C to 40°C in 1° increments Temperature Control ± 2°C of set temperature Ambient Operating Range 16°C to 38°C Accel / Decel Profiles 2/3 Heat Output 6900 BTU/hr (2.0 kW) Drive Type / Coolinge SR* drive / Air-cooled Refrigeration Non-CFC, non-ozone depleting refrigerant Sound Level 57 dBA (0.91 m / 3 ft from instrument at maximum speed) Sterile Filter Available Dimensions (with door closed) 71 W x 86 D x 86 H cm (28 W x 34 D x 34 H in) Weight 290 kg (640 lbs) User-Defined Programs None Time Settings 1 to 180 minutes, Hold Delayed Start No Key Lock-Out No * SR drives are manufactured by Beckman Coulter, Inc. with technology licensed from Switched Reluctance Drives Limited. Part Numbers 200/208/240 V 50/60 Hz 230 V 50 Hz 220/380 V 50 Hz, 3-Phase Avanti J-26S XP B14535 B14536 B14537 Avanti J-26S XP with Elutriation B14541 B14542 B14543 200/208/240 V 50/60 Hz 230 V 50 Hz 220/380 V 50 Hz, 3-Phase B22984 B22985 B22987 Model BioSafe Package Avanti J-26S XP Beckman Coulter High Performance Centrifuges 1-5 www.beckmancoultercentrifugation.com High Performance Centrifugation 1 Avanti J-E High Performance Centrifuge Compact High Performance Centrifuge that fits directly in your lab Whether your application is related to cellular, genetic, or protein analysis, the Avanti J-E with speeds up to 21 000 rpm (53 300 x g) coupled with powerful SR* drive technology provides you with fast separations. A comprehensive line of labware, with up to twenty-four 96-well microtiter plate processing, 4 x 1L bottles, and HarvestLine System Liners extend the versatility of this centrifuge. For clinical research applications, conical tubes and bottles for swinging bucket rotors spin volumes of 15, 50, 250, and 500 mL for effective blood component isolation with a variety of gradient kits. The J-E is energy efficient for low heat output plus the quiet operation ensures a comfortable, productive work environment. Specifications Maximum Speed 21 000 rpm Maximum g-force 53 300 × g Speed Control Actual rotor speed, ± 50 rpm of set speed Drive Type Switched Reluctance Drive* Drive Cooling Air-cooled Centrifuge Warranty 1 year Drive Warranty 2 years Refrigeration System Non-CFC, non-ozone-depleting refrigerant Max. Capacity Volume 4 000 mL Ambient Temperature Range 15° to 35°C Set Temperature Range -10° to 40°C in 1° increments Temperature Control ± 2°C of set Time Setting 1 min. to 99:59 hours, hold Acceleration/Deceleration Rates 2 accel/3 decel Heat Output 2.0 kW (6 900 BTU/hr) Sound Level < 64 dBa (3 ft. from instrument at maximum speed) Dimensions 63.5 cm x 80 cm x 91.4 cm (25 in. W x 31.5 in. D x 36 in. H) Weight 267.4 kg (589 lb) Avanti J-E High Performance Centrifuge Part Numbers Avanti J-E Avanti J-E 208/240 V 50/60 Hz 230 V 50 Hz 200 V 50/60 Hz 369001 369003 369005 200/208/240 V 50/60 Hz 230 V 50/60 Hz 220/380 V 50/60 Hz 969352 A20698 A20699 * Manufactured under license from Switched Reluctance Drives Limited, Harrogate, UK. 1-6 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com High Performance Centrifugation 1 Avanti J-30I High Performance Centrifuge The Maximum g-force for High Performance The Avanti J-30I High Performance Centrifuge System gives you the fastest separations possible—in the shortest amount of time. Swinging bucket and fixed-angle rotors provide maximum separation forces in excess of 100 000 x g at speeds up to 30 000 rpm. Your productivity is ensured by unmatched accel/decel rates and an easy run set-up. Your sample spends more time at full force and less time in the centrifuge. Specifications Maximum Speed 30 000 rpm Maximum g-force 110 500 × g Speed Control ± 10 rpm of set speed or 0.15%, whichever is greater Imbalance Tolerance ± 2.5% opposing sample imbalance Drive Type Microprocessor-controlled Switched Reluctance Drive* Centrifuge Warranty 1 year Drive Warranty 3 years Drive Cooling Air-cooled Refrigeration System Non-CFC, non-ozone depleting refrigerant Max. Capacity Volume 4 000 mL Single Tube Sample Volume Range 1.5 – 1 000 mL Set Temperature Range -20° to 40°C in 1° increments Temperature Control ± 2°C of set User Defined Programs Up to 30 two-step programs Time Setting 1 min. to 99:59 hours, hold or ω2t Acceleration/Deceleration Rates 12 accel/13 decel Friction Reduction System Yes Zonal Capability Yes Dynamic Rotor Inertia Check Automatic Heat Output 2.0 kW (6900 BTU/hr) Sound Level < 57 dBa (3 ft. from instrument at 30 000 rpm) Dimensions 71 cm x 86 cm x 86 cm (28 in. W × 34 in. D × 34 in. H) Weight 310 kg (680 lb) Avanti J-30I High Performance Centrifuge Part Numbers Avanti J-30I Avanti J-30I with Elutriation Avanti J30I 200/208/240 V 60 Hz 230 V 50 Hz 220/380 V 50 Hz, 3-Phase 363118 363120 363121 200/208/240 V 50/60 Hz 230 V 50 Hz 220/380 V 50 Hz, 3-Phase 363122 363124 363125 200/208/240 V 50/60 Hz 230 V 50 Hz 220/380 V 50 Hz, 3-Phase A20691 A20692 A20693 * Manufactured under license from Switched Reluctance Drives Limited, Harrogate, UK. Beckman Coulter High Performance Centrifuges 1-7 www.beckmancoultercentrifugation.com High Capacity Centrifugation 1 J6-MI High Capacity Centrifuge It Spins Volumes With six-liter capacity and an innovative range of rotors, carriers, and adapters, this centrifuge can handle multiple high-capacity applications. Ideal for bioprocessing, clinical and blood sample preparation, the J6-MI is the standard for quiet and convenient operation. Its self-balancing rotor system corrects for imbalances during a run, without shutdown. Its microprocessor-controlled induction motor provides high torque, fast acceleration, and long motor life. And the J6-MI generates speeds and forces up to 6 000 rpm and 6 840 x g. Specifications Maximum Speed 6 000 rpm Maximum g-force 6 840 × g Speed Control ± 20 rpm of set speed Drive Type High-torque, variable-frequency induction motor Drive Cooling Indirect drive system Refrigeration System Non-CFC, non-ozone-depleting refrigerant Max. Capacity Volume 6 Liters Ambient Temperature Range 15° to 35°C Set Temperature Range –20°C to 40°C in 1° increments Temperature Control ± 2°C of set temperature after equilibration Ambient Operating Range 16°C to 38°C Acceleration/Deceleration Rates 9 accel/9 decel Heat Output < 7000 BTU/hr (1.9 kW) Sound Level < 68 dBa (0.91 m/3 ft. from instrument at maximum speed) Dimensions 71 cm x 84 cm x 91 cm (25 in. W x 33 in. D x 36 in. H) Weight 252 kg (5555 lb) J6-MI High Capacity Centrifuge Part Numbers J6-MI High Capacity Centrifuge with Microprocessor Control and Brushless Induction Drive 208 V 60 Hz 240 V 50 Hz 220 V 50 Hz 360291 360292 360293 Note: Only values with tolerances or limits are guaranteed data. Values without tolerances are informative data, without guarantee. 1-8 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com High Capacity Centrifugation 1 Avanti J-HC Centrifuge The capacity to impress. The Avanti J-HC High Capacity Centrifuge provides you with a complete solution for batch bioprocessing. A maximum of 9 liters can be spun at speeds of 5 000 rpm and 7 480 × g for greater sample throughput. This allows processing of up to 36 liters per hour when harvesting bacteria. Enhanced operator safety is provided with disposable HarvestLine System Liners. Specifications Avanti J-HC High Capacity Bioprocessing Centrifuge System Maximum Speed 10 000 rpm Maximum g-force 17,100 × g (JA-10 rotor @ 10 000 rpm) Speed Control ± 25 rpm of set speed Max. Capacity 9 000 mL Single Bucket Volume 2 250 mL Set Temperature Range -10° to 40°C Temperature Control ± 2°C User Defined Programs Up to 30 two-step programs Friction Reduction Automatic Maximum Heat Dissipation to Room 2.0 kW (6 900 BTU/hr) Noise Level 60 dBa (3 ft. from instrument at 10 000 rpm) Weight 300 kg (660 lb) Dimensions 71 cm x 86 cm x 86 cm (28 in. W x 34 in. D x 34 in. H) Beckman Coulter High Performance Centrifuges Part Numbers Avanti J-HC 200/208/240 V 50/60 Hz 230 V 50 Hz 380 V 50 Hz, 3-Phase 367501 367502 367503 1-9 www.beckmancoultercentrifugation.com High Performance/High Capacity Centrifugation 1 Rotor Compatibility Chart Avanti J-30I Max. RPM/ g-Force Avanti J-26S Max. RPM/ g-Force Avanti J-E Max. RPM/ g-Force J6-MI Avanti J-HC Angle Containment JA-30.50 Ti 30 000 108 860 26 000 81 800 N/A N/A N/A 34° Single- or dual-locking lid/ fluid annulus JA-25.50† 25 000 75 600 25 000 75 600 21 000 53 300 N/A N/A 34° Single- or dual-locking lid/ fluid annulus JA-25.15† 25 000 74 200 25 000 74 200 N/A N/A N/A 25° Single- or dual-locking lid/ fluid annulus JA-21 21 000 50 400 21 000 50 400 21 000 50 400 N/A N/A 40° JA-20.1† 20 000 51 500 20 000 51 500 20 000 51 500 N/A N/A 23° JA-20† 20 000 48 400 20 000 48 400 20 000 8 400 N/A N/A 34° JA-18.1 18 000 42 100 18 000 42 100 N/A N/A N/A 45° N/A JA-18† 18 000 47 900 18 000 47 900 16 000 37 800 N/A N/A 23° N/A JA-17† 17 000 39 800 17 000 39 800 17 000 39 800 N/A N/A 25° JLA-16.250† 16 000 38 400 16 000 38 400 16 000 38 400 N/A N/A 25° Single- or dual-locking lid/ fluid annulus JA-14.50† 14 000 35 000 14 000 35 000 14 000 35 000 N/A N/A 35° Single- or dual-locking lid/ fluid annulus JA-14† 14 000 30 100 14 000 30 100 14 000 30 100 N/A N/A 25° JA-12† 12 000 23 200 12 000 23 200 12 000 23 200 N/A N/A 35° Single- or dual-locking lid/ fluid annulus JLA-10.500† 10 000 18 500 10 000 18 500 10 000 18 500 N/A N/A 20° Sealing canister covers JA-10 10 000 17 700 10 000 17 700 10 000 17 700 6 000 6 370 10 000 17 700 25° JLA-9.1000 9 000 16 800 9 000 16 800 6 300 8 230 N/A N/A 20° Integrated bottle seal JLA-8.1000† N/A 8 000 15 970 N/A N/A 20° Integrated bottle seal Avanti J-E J6-MI 8 000 15 970 Fixed-Angle Rotors Avanti J-30I Avanti J-26S Avanti J-HC Angle Containment †This rotor was tested to demonstrate containment of microbiological aerosols under normal operating conditions of the associated Beckman Coulter centrifuge, when used and maintained as instructed. Validation of the microbiological containment was done at an independent, third-party facility (CAMR, Porton Down, UK or USAMARIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and, thus, containment. 1-10 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com High Performance /High Capacity Centrifugation 1 Rotor Compatibility Chart (continued) Max. RPM/ g-Force Swinging Bucket Rotors JS-24.38 Max. RPM/ g-Force JS-5.3 24 000 103 900 24 000 110 500 13 000 26 500 7 500 10 400 5 900 6 570 N/A JS-4.3 N/A JS-4.0 N/A JS-5.2 N/A N/A N/A 5 200 6 840 N/A Horz. JS-5.0 N/A N/A N/A N/A 5 000 7 480 Horz. JS-4.2 N/A N/A N/A 4 200 5 020 4 200 5 020 Horz. Aeroseal Cover JS-4.2A N/A N/A N/A 4 200 5 020 N/A Horz. Aeroseal Cover JS-4.2SM N/A N/A N/A 4 200 4 900 N/A Horz. JS-4.2SMA N/A N/A N/A 4 200 4 900 N/A Horz. JS-4.0 N/A N/A N/A 4 000 4 050 N/A Horz. Aeroseal Cover JS-3.0 N/A N/A N/A 3 000 2 560 N/A Horz. Aeroseal Cover JS-24.15 JS-13.1 JS-7.5 JS-5.9 Avanti J-30I Max. RPM/ g-Force 10 000 18 000 10 000 19 200 13 000 26 500 7 500 10 400 N/A Max. RPM/ g-Force 5 300 6 130 4 300 4 220 4 000 4 050 Avanti J-26S Max. RPM/ g-Force Elutriation, Continuous Flow, and Zonal Rotors JE-5.0 JCF-Z Std. Core JCF-Z Large Core JCF-Z Small Core JCF-Z Reograd Core JCF-Z Zonal Core N/A 20 000 39 900 20 000 39 900 20 000 36 300 20 000 39 900 20 000 39 900 5 000 4 700 20 000 39 900 20 000 39 900 20 000 36 300 20 000 39 900 20 000 39 900 Beckman Coulter High Performance Centrifuges N/A N/A N/A Horz. Cap, O-ring N/A N/A N/A Horz. Cap, O-ring N/A N/A N/A Horz. N/A N/A N/A Horz. N/A N/A N/A N/A Horz. N/A 5 300 6 130 N/A N/A N/A Horz. N/A N/A N/A Horz. Bucket Covers N/A N/A N/A Horz. Aeroseal Cover Aeroseal Cover Avanti J-E Max. RPM/ g-Force N/A N/A N/A N/A N/A N/A 1-11 www.beckmancoultercentrifugation.com High Performance/High Capacity Centrifugation 1 High Performance and High Capacity Rotor Summary Rotor Type Part Number Maximum Speed (rpm) Maximum Force at rmin (g) Maximum Force at rmax (g) k Factor Number Tubes/Bottles and Size (diameter x length) mm/in. Rotor Capacity (mL) Approx. Comments Accel. Time1 (min:sec) 30 000 40 320 108 860 280 8 x 50 mL 29 x 104 mm (1.125 x 4 in.) 400 mL 5:15a Harvesting bacteria, processing tissue culture, subcellular particulates, routine pelleting such as precipitates and phase separation. 25 000 26 950 75 600 418 8 x 50 mL 29 x 104 mm (1.125 x 4 in.) 400 mL 3:30b High-force, efficient pelleting of cell particles from tissue homogenates. Short column virus purification. 25 000 36 400/ 22 400 74 200/ 60 200 265/ 380 24 x 15 mL 18 x 100 mm (0.75 x 4 in.) 360 mL 3:15b High-force, efficient pelleting of subcellular particles, bacteria, algae, and chloroplasts. Short column banding of virus and subcellular particles. Fixed-Angle Rotors JA-30.50 Ti 363420 Biosafety 363421 Single Lock Lid JA-25.50 363058 Biosafety Lid 363055 Single Lock Lid JA-25.15 363050 Biosafety Lid 363054 Single Lock Lid JA-21 334845 21 000 22 200 50 400 470 18 x 10 mL 16 x 80 mm (0.625 x 3 in.) 180 mL 1:30b High-force, fast, efficient separation of many samples in small volume. Viruses, bacteriophage, mitochondria, nuclei. JA-20.1 342095 20 000 28 700/ 21 100 51 500/ 43 900 371/ 465 32 x 15 mL 18 x 99 mm (0.625 x 4 in.) 480 mL 1:30b High-force, large volume. Has 2 concentric rows of 15-mL tubes. Efficient separation of particles with 100 S or larger sedimentation coefficients. JA-20 334831 20 000 14 300 48 400 769 8 x 50 mL 29 x 104 mm (1.125 x 4 in.) 400 mL 1:30b Harvesting bacteria and cell membranes, processing tissue homogenates, separating cell particulates. JA-18.1 347824 18 000c 34 500c 42 100c 156c 24 x 1.8 mL 11 x 38 mm (0.4 x 1.5 in.) 43.2 mL 1:20b High-force sedimentation in microcentrifuge-sized tubes under refrigerated conditions. Tube oriented at either a 25° or 45° angle. JA-18 369679 18 000 23 200 47 900 566 10 x 100 mL 38 x 102 mm (1.5 x 4 in.) 1 liter 6:30b High-force, large volume. Pelleting bacteria, cell membranes, and subcellular organelles. JA-17 369691 17 000 18 180 39 800 1 060 14 x 50 mL 29 x 104 mm (1.125 x 4 in.) 700 mL 2:30b Harvesting bacteria and cell membranes, processing tissue homogenates, separating cell particulates. JLA-16.250 363930 Biosafety Lid 16 000 13 200 38 400 1090 6 x 250 mL 62 x 120 mm (2.5 x 5.5 in.) 1.5 liters 3:30b Harvesting bacteria and cell membranes, processing tissue homogenates, separating cell particulates. 14 000 19 000 35 000 787 16 x 50 mL 30 x 115 mm 800 mL 2:00 Pelleting and density gradient separations, proteins, nucleic acids, cells, viruses and blood. 363934 with Single Lock Lid JA-14.50 B19955 Biosafety Lid B19956 Single Lock Lid JA-14 339247 14 000 7 680 30 100 1 764 6 x 250 mL 62 x 120 mm (2.5 x 4.8 in.) 1.5 liters 4:00b General-purpose, largevolume, and multi-tube processing. JA-12 360992 Biosafety Lid 12 000 11 500 23 200 1 244 12 x 50 mL 30 x 103 mm conical (1.17 x 4 in.) 600 mL 3:30b General pelleting of cells, bacteria, and food products. Separating of proteins, viruses, and subcellular fractions. Phase separations and binding studies. 360993 with Single-locking Lid 1 Accel times are approximate, and subject to change. b Typical accel time in Avanti J-25 Series. 1-12 a c Typical accel time in Avanti J-30I. At a 45° angle. Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com High Performance/High Capacity Centrifugation 1 High Performance and High Capacity Rotor Summary (continued) Rotor Type Part Number Maximum Speed (rpm) Maximum Force at rmin (g) Maximum Force at rmax (g) k Factor Number Tubes/Bottles and Size (diameter x length) Rotor Capacity (mL) Approx. Comments Accel. Time1 (min:sec) Fixed-Angle Rotors (continued) JLA-10.500 369681 with Canisters 10 000 6 050 18 600 2 850 6 x 500 mL 69 x 160 mm (2.75 x 6.5 in.) 3 liters 2:30a Lightweight, high-volume, fixedangle rotor for initial processing of tissue homogenate and other large particles. JA-10 369687 10 000 4 260 17 700 3 610 3 liters 4:30a JLA-9.1000 366754 9 000 7 440 16 800 2 544 6 69 (2.75 4 95 (3.8 4 liters 2:30b JLA-8.1000 363688 8 000 8 530 15 970 2 482 6 x 1000 mL 95 x 191 mm (3.8 x 7.65 in.) 6 liters 6:00b High-volume, fixed-angle rotor for initial processing of tissue homogenate and other large particles. General purpose, large-volume processing, pelleting of bacteria cell organelles, viruses, and precipitates. General purpose, large-volume processing, pelleting of bacteria subcellular organelles, viruses and precipitates. 231 mL 5:15c x x x x x x 500 mL 160 mm 6.5 in.) 1000 mL 191 mm 7.65 in.) Swinging-Bucket Rotors JS-24.38 360743 24 000 48 600 103 900 334 6 x 38.5 mL 25 x 89 mm (1 x 3.5 in.) JS-24.15 362396 24 000 50 900 110 500 376 6 x 15 mL 16 x 96 mm (0.625 x 3.75 in.) 90 mL 5:15c JS-13.1 346963 13 000 7 760 26 500 1 841 6 x 50 mL 29 x 105 mm (1.125 x 4 in.) 300 mL 2:30a JS-7.5 336380 7 500 3 210 10 400 5 287 4 x 250 mL 62 x 136 mm (2.5 x 5.5 in.) 1L 1:00a JS-5.9 369331 5 900 5 400 6 570 various 10 microplates JS-5.3 (AllSpin) 368690 2 920 5 170 6 870 various 4 x 500 mL conical 24 microplates 2L 2:00d JS-5.2* 339087 5 200 2 600 6 840 9 051 4 Liters 4 Blood Bags 12 Microplates 148 RIA-Tubes 4L 2:30 JS-5.0 367820 5 000 3 020 7 480 4 x 2.25 L 9L 3:30 JS-4.3 362734 3 250 1 532 4 220 4 x 750 mL 96 x 130 mm (3.8 x 5.2 in.) 3L 1:00b 1 Accel times are approximate and subject to change. a Typical accel time in Avanti J-25 Series. b Typical accel time in Avanti J-26 XP Series. * Only for J6-MI. Beckman Coulter High Performance Centrifuges 11 800 1:00a Harvesting bacteria, processing tissue homogenates, subcellular particulates, routine pelleting such as precipitates and phase separations. Harvesting bacteria, processing tissue homogenates, subcellular particulates, routine pelleting such as precipitates and phase separations. Density gradient centrifugation of cells. Sedimentation of nuclei and protein or nuclei acid precipitates. Clarification of tissue homogenates. Initial processing of cells and removal of cell debris from culture media. Accepts round-bottom bottles for easier handling of pellets. High-throughput processing (DNA or RNA kits), serial dilution of small volumes. Sucrose/glycerol gradients, centrifugal filtration, binding studies, clearing debris/large particles, pelleting, plasma protein precipitates. Rapid sedimentation of protein precipitates, large particles, cells, and cell debris. It can be used for binding studies and separating serum from whole blood. Separating bacterial yeast, and tissue homogenates; harvesting cultures. Rapid sedimentation of protein precipitates, large particles, cells, binding studies, and separating serum from whole blood. c Typical accel time in Avanti J-30I (JS rotors using mandatory slow accel setting). d Typical accel time in Avanti J-E. 1-13 www.beckmancoultercentrifugation.com High Performance/High Capacity Centrifugation 1 High Performance and High Capacity Rotor Summary (continued) Rotor Type Part Number Maximum Speed (rpm) Maximum Force at rmin (g) Maximum Force at rmax (g) k Factor Number Tubes/Bottles and Size (diameter x length) Rotor Capacity (mL) Approx. Accel Time Comments Rapid sedimentation of protein precipitates, large particles, cells, and cell debris. It can be used for binding studies and separating serum from whole blood. Rapid sedimentation of protein precipitates, large particles, cells, and cell debris. It can be used for binding studies and separating serum from whole blood. Separation of serum from whole blood, blood component separation. Separation of serum from whole blood, blood component separation. Swinging-Bucket Rotors (continued) JS-4.2 339080 4 200 2 250 5 020 11 504 6 Liters, 6 Blood Bags, 18 Microplates, 336 RIA-Tubes 6L 2:30 JS-4.2A** 366695 4 200 2 250 5 020 11 504 6 Liters, 6 Blood Bags, 18 Microplates, 336 RIA-Tubes 6L 2:30 JS-4.2/SM** 348394 4 200 2 290 4 900 JS-4.2/SMA** 366670 4 200 2 290 4 900 JS-4.0 339086 4 000 1 540 4 050 JS-3.0* 339086 3 000 1 150 2 560 6 Blood Bags 18 Microplates 6 Blood Bags 18 Microplates 15 296 2:30 2:30 4 x 000 97 x 167 (3.82 x 6.57 in.) 4L 6 x 1000 97 x 167 6L 2:00b Rapid sedimentation of protein precipitates, large particles, cells and cell debris, as well as binding studies and separating serum from whole blood. Continuous-Flow Rotor JCF-Z 335140 (standard core) 20 000 32 000 39 900 100 N/A 660 mL Purification of viruses and/or concentration of large volumes of solution. Pelleting or sedimenting on a sucrose cushion. Maximum pellet size: 400 mL. 357544 (small pellet core) 20 000 23 300 36 300 281 N/A 240 mL Pelleting liquids that contain a low ratio of solids–such as bacterial cultures, or water containing clay particles or algae. Maximum pellet size: 200 mL. 336283 (large pellet core) 20 000 22 850 39 900 293 N/A 1 250 mL Pelleting solutions that have high solid-to-water ratios as high as 1:2 slurries. Maximum pellet size: 800 mL. 20 000 9 000 39 900 710 69 mm 1 900 mL Fast start up. Dynamic loading and unloading. Isopycnic banding, linear, and discontinuous gradients. Subcellular fractions from tissue homogenates, algae, and chloroplasts. 20 000 11 650 39 900 779 63 mm 1 750 mL No rotating seal. Static loading and unloading. Gradient reorients in rotor. Especially useful for fragile material such as DNA strands. 5 000 2 410 4 700 6 785 ——— 40 mL The counterflow centrifugation elutriation system is a gentle, yet powerful technique for harvesting large populations of living cells, resulting in high viability rates. Zonal Rotor JCF-Z 354006 Reorienting Gradient Rotor JCF-Z 354005 Elutriation JE-5.0 356900 *JS-3.0 rotor is for use in Beckman Coulter J6 Series centrifuges only per IFU J6-TB-0075C. **Only for J6. 1-14 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com Protein Pelleting ammonium sulfate precipitation Sucrose/glycerol gradient Centrifugal filtration 1-50 mL Subcellular Centrifugal filtration <1.0 mL Fractions Chromatin/ Sucrose gradient isolation Nucleosomes Microsomes Pelleting Microsomal membrane fraction Mitochondria Pelleting Sucrose gradient isolation Nucleic Pelleting Cell Pelleting Membranes Sucrose gradient isolation Binding studies Ribosomes/ Pelleting Polysomes Sucrose gradient isolation Cytosol Clarification Lysate/Tissue Clearing debris and large particles Homogenates Clearing Media Clearing debris and large particles Nucleic Acids Pelleting alcohol precipitation Phenol/chloroform extraction ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Spin columns Pelleting mammalian cells Density gradient separation Viruses Pelleting PEG precipitates Density gradient isolation Blood Pelleting Plasma protein precipitation JS-4.2 JS-5.3 JS-13.1 JS-24.38 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Minipreps in 96-well plates Cells Pelleting bacteria JLA-8.1000 JLA-9.1000 JA-10 JLA-10.500 JA-12 JA-14 JA-14.50 JLA-16.250 JA-17 JA-18.1 JA-18 JA-20 JA-20.1 JA-21 JA-25.15 Specific Application JA-25.50 Bioseparation JA-30.50 Ti ROTOR SELECTION BY APPLICATION† Blood sample preparation Density gradients to isolate blood cells ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Maximum rotor speeds may differ between instrument models. For complete rotor specifications, please refer to our High Performance and High Capacity centrifuge catalog or visit beckmancoulter.com. ◆ ³BioSafe when used with Aeroseal covers. ⁴BioSafe when used with Aerosolve canisters. ⁵J6-M� must have door and strobe. †Selected rotor has the capability (x g, volume, labware) to accommodate the application, but may not be the most optimal/efficient choice for the specific application. All labware sold separately. Beckman Coulter High Performance Centrifuges 1-15 1 www.beckmancoultercentrifugation.com JA-30.50 Ti JA-30.50 Ti 8 x 50 mL Fixed-Angle Rotor, Titanium Major applications: Harvesting bacteria, processing tissue homogenates, subcellular particulates, routine pelleting such as precipitates and phase separations. Axis of Rotation 34° 1 rmin (40 mm) rav (74 mm) rmax (108 mm) Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 30 000 108 860 280 8 × 50 mL 29 × 104 mm 1.125 × 4 in 400 mL For use in Avanti J Series centrifuges (except Avanti J-E and J-HC) centrifuges. No. 363420. JA-30.50 Fixed-Angle Ti Rotor with Single Lock Lid. No. 363421. JA-30.50 Fixed-Angle Ti Rotor with Single Lock Lid. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed ——— ——— 75 600 403 25 000 1 ——— 91 000 75 600 244 403 30 000 25 000 Bottles with Screw-On Caps Polypropylene 50.0 357003 25 29 x 104 Polycarbonate 10.0 50.0 355672 357002 25 25 16 x 80 361703 (qty. of 2) 29 x 104 ——— Polypropylene 50.0 357001 6 29 x 104 ——— ——— 108 800 280 30 000* Polycarbonate 50.0 357000 6 29 x 104 ——— ——— 108 800 280 30 000 1.5 357448 500 11 x 38 361705 (qty. of 2) 3 73 400 126 30 000 50.0 363664 25 29 x 104 ——— ——— 75 600 403 25 000 Bottles with Cap Assemblies Tubes with Snap-On Caps Polypropylene Thickwall Polycarbonate Polypropylene 1.5 356090 500 11 x 38 361705 (qty. of 2) 3 73 400 126 30 000 50.0 357005 25 29 x 104 ——— ——— 75 600 403 25 000 Thickwall Polycarbonate 50.0 363647 25 29 x 104 ——— ——— 108 800 280 30 000* Thickwall Polypropylene 50.0 357007 25 29 x 104 ——— ——— 108 800 280 30 000 ——— ——— ——— ——— ——— 12 x 75 13 x 100 16 x 80 18 x 80 29 x 104 356970 (qty. of 1) 356976 (qty. of 1) 342327 (qty. of 1) 870329 (qty. of 1) 870331 (qty. of 1) 1 1 1 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— Thickwall Polypropylene Open-Top Tubes Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom 5.0 8.0 10.0 15.0 30.0 ——— ——— ——— ——— ——— * At 2°C; at 25°C, maximum speed must be limited to 26 000 rpm for tube 357001 and 29 000 rpm for tube 363647. Rotor Replacement Parts 870612 11757 363424 363430 363431 O-ring for Rotor Lid Small O-ring for Rotor Lid Lid Assembly, Biosafety (tie-down assembly included) Lid Assembly, Single-locking Tie-down for Single-locking Lid Adapters 361703 1-16 361705 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JA-25.50 JA-25.50 8 x 50 mL Fixed-Angle Rotor, Aluminum Axis of Rotation Major applications: Harvesting bacteria, processing tissue homogenates, subcellular particulates, routine pelleting such as precipitates and phase separations. rmin (38.5 mm) rav (73.2 mm) rmax (108 mm) Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 25 000 75 600 418 8 x 50 mL 29 x 104 mm 1.125 x 4 in 400 mL 34° For use in Avanti J Series centrifuges. No. 363058. JA-25.50 Fixed-Angle Rotor with Biosafety Lid. No. 363055. JA-25.50 Fixed-Angle Rotor with Single Lock Lid. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed ——— ——— 75 600 418 25 000 1 ——— 63 240 75 600 350 418 25 000 25 000 Bottles with Screw-On Caps Polypropylene 50.0 357003 25 29 x 104 Polycarbonate 10.0 50.0 355672 357002 25 25 16 x 80 361703 (qty. of 2) 29 x 104 ——— Polypropylene 50.0 361694 24 29 x 104 ——— ——— 75 600 418 25 000 Polycarbonate 50.0 361693 24 29 x 104 ——— ——— 75 600 418 25 000 ——— ——— 75 600 418 25 000 3 ——— 50 960 75 600 182 418 25 000 25 000 Bottles with Cap Assemblies Tubes with Snap-On Caps Thickwall Polycarbonate 50.0 363664 25 29 x 104 Thickwall Polypropylene 1.5 50.0 356090 357005 500 25 9.5 x 38 361705 (qty. of 2) 29 x 104 ——— Open-Top Tubes Polypropylene 1.5 357448 500 9.5 x 38 361705 (qty. of 2)5 3 50 960 182 25 000 Thickwall Polycarbonate 50.0 363647 25 29 x 104 ——— ——— 75 600 418 25 000 Thickwall Polypropylene 50.0 357007 25 29 x 104 ——— ——— 75 600 418 25 000 ——— ——— ——— ——— ——— 12 x 75 13 x 100 16 x 80 18 x 80 29 x 104 356970 (qty. of 1) 356976 (qty. of 1) 342327 (qty. of 1) 870329 (qty. of 1) 870331 (qty. of 1) 1 1 1 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom * 5.0 8.0 10.0 15.0 30.0 ——— ——— ——— ——— ——— Order cap separately (pkg. of 25): 356264 (natural), 357359 (red), 357360 (green), 357361 (yellow), or 357362 (blue). Rotor Replacement Parts 870612 11757 363023 363053 O-ring for Rotor Lid Small O-ring for Rotor Lid Lid Assembly, Biosafety (Tie-down Assembly included) Lid Assembly, Single Lock (Tie-down Assembly included) Adapters 361703 361705 Beckman Coulter High Performance Centrifuges 1-17 1 www.beckmancoultercentrifugation.com JA-25.15 JA-25.15 24 x 15 mL Fixed-Angle Rotor, Aluminum Axis of Rotation Major applications: Harvesting bacteria, processing tissue homogenates, subcellular particulates, routine pelleting such as precipitates and phase separations. rmin (52 mm) 1 rav (79 mm) rmax (106 mm) 25° Axis of Rotation rmin (32 mm) Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity Outer Row 25 000 74 200 265 360 mL Inner Row 25 000 60 200 380 24 x 15 mL 18 x 100 mm 0.75 x 4 in For use in Avanti J Series centrifuges (except Avanti J-E) centrifuges. rav (59 mm) rmax (86 mm) 25° No. 363050. JA-25.15 Fixed-Angle Rotor with Biosafety Lid. No. 363054. JA-25.15 Fixed-Angle Rotor, Single Lock Lid. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed (Outer Row) Bottles with Screw-On Caps Polycarbonate 10.0 355672 25 16 x 80 342327 1 60 200 204 25 000 Thickwall Polypropylene 4.0 10.0 355644 355640 25 25 13 x 64 16 x 75 303313 342327 1 1 49 000 56 700 120 180 25 000 25 000 Thickwall Polycarbonate* 4.0 10.0 15.0 355645 355630 342080 25 25 100 13 x 64 16 x 75 18 x 98 303313 342327 ——— 1 1 ——— 49 000 56 700 74 200 120 180 265 25 000 25 000 25 000 Thickwall Polyethylene* 15.0 342081 100 18 x 98 ——— ——— 74 200 265 25 000 Thickwall Polypropylene* 15.0 342082 100 18 x 98 ——— ——— 74 200 265 25 000 ——— 12 x 75 342329 (qty. of 1) 1 ——— ——— ——— Open-Top Tube Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom * 3.0 ——— To order caps for 15-mL tubes 342080, 342081, and 342082, use part number 343656 for a package of 50. . Rotor Replacement Parts 964911 11757 363024 363052 Large O-ring for Rotor Lid Small O-ring for Rotor Lid Lid Assembly, Biosafety (Tie-down Assembly included) Rotor Lid Assembly, Single Lock (Tie-down Assembly included) Adapters 303313 1-18 342327 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JA-21 JA-21 18 x 10 mL Fixed-Angle Rotor, Aluminum Axis of Rotation rmin (45 mm) Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 21 000 50 400 470 18 x 10 mL 16 x 80 mm 0.625 x 3 in 180 mL rav (73 mm) 1 rmax (102 mm) 40° For use in Avanti J Series centrifuges. No. 334845. JA-21 Fixed-Angle Rotor for 21 000 rpm operation. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Screw-On Caps Polycarbonate 10.0 355672 25 16 x 80 ——— ——— 50 400 470 21 000 Thickwall Polypropylene 10.0 355640 25 16 x 76 ——— ——— 50 400 470 21 000 Thickwall Polycarbonate 10.0 355630 25 16 x 76 ——— ——— 50 400 470 21 000 ——— 12 x 75 356972 (qty. of 1) 1 ——— ——— ——— Open-Top Tubes Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom 5.0 ——— Rotor Replacement Parts 870612 870980 335107 343631 369349 Beckman Coulter High Performance Centrifuges O-ring for Rotor Lid O-ring for Rotor Hub Rotor Lid Lid Attachment Bolt Assembly Rotor Lid Assembly (Tie-down Assembly included) 1-19 www.beckmancoultercentrifugation.com JA-20.1 JA-20.1 32 x 15 mL Fixed-Angle Rotor, Aluminum Major applications: High-force, large-volume separation of particles with 100 S or larger sedimentation coefficients. 1 Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity Outer Row 20 000 51 500 371 480 mL Inner Row 20 000 43 900 465 32 x 15 mL 18 x 99 mm 0.625 x 4 in For use in Avanti J Series centrifuges. No. 342095. JA-20.1 Fixed-Angle Rotor for 20 000 rpm operation. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor* Maximum Speed (Outer Row) Bottles with Screw-On Caps Polycarbonate 10.0 355672 25 16 x 80 342327 1 47 900 325 20 000 Thickwall Polypropylene 10.0 355640 25 16 x 76 342327 1 47 900 325 20 000 Thickwall Polycarbonate 10.0 15.0 355630 342080 25 100 16 x 76 18 x 98 342327 ——— 1 ——— 47 900 51 500 325 371 20 000 20 000 Thickwall Polyethylene 15.0 342081 100 18 x 98 ——— ——— 51 500 371 20 000 Thickwall Polypropylene 15.0 342082 100 18 x 98 ——— ——— 51 500 371 20 000 ——— ——— ——— ——— ——— 12 x 75 12 x 75 13 x 100 16 x 99 18 x 99 342329 (qty. of 1) 356971 (qty. of 1) 356977 (qty. of 1) 342348 (qty. of 1) 342643 (qty. of 1) 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— Open-Top Tubes Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom 3.0 5.0 8.0 15.0 15.0 ——— ——— ——— ——— ——— 1 1 Caps for 15-mL Tubes Rotor Replacement Parts 343656 834301 811656 358368 341976 364915 392889 * Caps (box of 50) for 342080, 342081, and 342082 Tubes O-ring for Rotor Lid O-ring for Rotor Body Lid Attachment Bolt Assembly Rotor Lid Tie-down Kit Hold-down Knob, for use with filtration tubes regularly run without lid (in J2/J6 centrifuges only) 338896 Rotor Removal Tool 338689 Adapter Collar for 338896 Rotor Removal Tool Measured using the outer row of tubes. Adapters 342327 1-20 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JA-20 JA-20 8 x 50 mL Fixed-Angle Rotor, Aluminum Axis of Rotation Major applications: Harvesting bacteria and cell membranes, processing tissue homogenates, separating cell particulates. rmin (32 mm) rav (70 mm) rmax (108 mm) 34° Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 20 000 48 400 769 8 x 50 mL 29 x 104 mm 1.125 x 4 in 400 mL For use in Avanti J Series centrifuges. No. 334831. JA-20 Fixed-Angle Rotor for 20 000 rpm operation. Tubes and Bottles Tube Style/Material Minimum Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Screw-On Caps Polyethylene 50.0 357003 25 29 x 104 ——— ——— 48 400 769 20 000 Polycarbonate 10.0 50.0 355672 357002 25 25 16 x 80 29 x 104 342327/870329 ——— 1 ——— 43 500 48 400 650 769 20 000 20 000 Polypropylene 50.0 357001 6 29 x 104 ——— ——— 48 400 769 20 000 Polycarbonate 50.0 357000 6 29 x 104 ——— ——— 48 400 769 20 000 1.5 357448 500 11 x 38 344497* 6 48 400 769 20 000 50.0 363647 25 29 x 104 ——— ——— 48 400 769 20 000 Bottles with Cap Assemblies Tubes with Snap-On Caps Polypropylene Natural Thickwall Polycarbonate Polyethylene Thickwall Polypropylene Orange Yellow Green Blue Natural 1.8 340196 500 11 x 39 344497* 6 48 400† 769 20 000 50.0 357005 25 29 x 104 ——— ——— 48 400 769 20 000 1.5 1.5 1.5 1.5 1.5 356094 356093 356092 356091 356090 500 500 500 500 500 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 344497* 344497* 344497* 344497* 344497* 6 6 6 6 6 48 400 48 400 48 400 48 400 48 400 769 769 769 769 769 20 000 20 000 20 000 20 000 20 000 50.0 357007 25 29 x 104 ——— ——— 48 400 769 20 000 ——— ——— ——— ——— 12 x 75 13 x 100 18 x 80 29 x 104 356970 (qty. of 1) 356976 (qty. of 1) 870329 (qty. of 1) 870331 (qty. of 1) 1 1 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— Open-Top Tubes Thickwall Polypropylene Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom 5.0 8.0 15.0 30.0 ——— ——— ——— ——— Rotor Replacement Parts Cap Assembly Replacement Parts 870612 811656 364914 368998 392889 356284 358627 O-ring for Rotor Lid O-ring for Rotor Hub Tie-down Kit Rotor Lid Hold-down Knob, for use with filtration tubes regularly run without lid (in J2/J6 centrifuges only) Rotor Removal Tool Adapter Collar for 338896 Rotor Removal Tool 338896 338689 * † 961582 Cap for 357000 and 357001 Bottle Insert for 357000 and 357001 Cap Assembly; order only as a replacement part O-ring for 357000 and 357001 Bottle Can be double-stacked. Force will vary depending on tube position. Calculated at rmax, g-force will be less for tubes located in upper adapter when adapters are stacked. Force will also vary depending on tube position in adapter. Adapters 342327 344497 870329 Beckman Coulter High Performance Centrifuges 1-21 1 www.beckmancoultercentrifugation.com JA-18.1 JA-18.1 24 x 1.8 mL Fixed-Angle Rotor, Aluminum Axis of Rotation 1 Major applications: High-force sedimentation in microcentrifuge tubes under refrigerated conditions. rmin (95.0 mm) rav (105 mm) rmax (116 mm) Max. RPM at 45° Angle* Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 18 000 42 100 156 24 x 1.8 mL 11 x 38 mm 0.4 x 1.5 in. 43.2 mL Max. RPM at 25° Angle* Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 17 000 36 300 91 24 x 1.8 mL 11 x 38 mm 0.4 x 1.5 in. 43.2 mL 45° Axis of Rotation rmin (101 mm) rav (106 mm) rmax (112 mm) For use in Avanti J Series centrifuges (except Avanti J-E). 25° No. 347824. JA-18.1 Fixed-Angle Rotor. Includes 24 reversible adapters. Tubes and Bottles Tube Style/Material Minimum Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters* Tubes per Adapter† g-Force k Factor Maximum Speed* Tubes with Snap-On Caps Polypropylene Natural Polyethylene Polypropylene * Orange Yellow Green Blue Natural Natural‡ 1.5 357448 500 11 x 38 347562 1 42 100 ——— 18 000 1.8 340196 500 11 x 39 347562 1 42 100 ——— 18 000 1.5 1.5 1.5 1.5 1.5 1.5 356094 356093 356092 356091 356090 343169 500 500 500 500 500 500 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 347562 347562 347562 347562 347562 347562 1 1 1 1 1 1 42 100 42 100 42 100 42 100 42 100 42 100 ——— ——— ——— ——— ——— ——— 18 000 18 000 18 000 18 000 18 000 18 000 Adapters included with rotor. Adapters are reversible, so that tube angle can be set at either 45° or 25°, depending on application requirements. Rotor Replacement Parts 11921 347821 364918 O-ring Rotor Knob Assembly Tie-down Kit Adapters 347562 1-22 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JA-18 JA-18 10 x 100 mL Fixed-Angle Rotor, Aluminum Axis of Rotation Major applications: High-force, large-volume. Pelleting bacteria, cell membranes, and subcellular organelles. Max. RPM rmin (64 mm) rav (98 mm) Max. g 18 000 47 900 (16 000 rpm* at 4°C and below) rmax (132 mm) 23° k Factor Number of Tubes Volume/Size Rotor Capacity 566 10 x 100 mL 38 x 102 mm 1.5 x 4 in 1L For use in Avanti J Series centrifuges. No. 369679. JA-18 Fixed-Angle Rotor for 18 000 rpm operation. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Quick-Seal Tubes Polypropylene 100.0 345776 25 38 x 102 ——— ——— 47 900 566 18 000 Ultra-Clear 100.0 345778 25 38 x 102 ——— ——— 47 900 566 18 000 Polycarbonate 70.0 355620 6 38 x 102 ——— ——— 47 900 566 18 000 Polypropylene 94.0 355624 6 38 x 102 ——— ——— 47 900 566 18 000 Bottles with Cap Assemblies Bottles with Screw-On Caps Polypropylene 50.0 357003 25 29 x 104 347539 1 44 000 ——— 18 000 Polycarbonate 50.0 357002 25 29 x 104 347539 1 44 000 ——— 18 000 1.5 1.5 1.5 1.5 1.5 1.5 1.5 356094 356093 356092 356091 356090 357448 343169 500 500 500 500 500 500 500 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 344497/347539†** 344497/347539†** 344497/347539†** 344497/347539†** 344497/347539†** 344497/347539†** 344497/347539†** 6 6 6 6 6 6 6 35 000 35 000 35 000 35 000 35 000 35 000 35 000 ——— ——— ——— ——— ——— ——— ——— 18 000 18 000 18 000 18 000 18 000 18 000 18 000 1.8 340196 500 11 x 39 344497/347539†** 6 35 000 ——— 18 000 Thickwall Polycarbonate* 50.0 363647 25 29 x 104 347539 1 44 000 ——— 18 000 Thickwall Polypropylene* 50.0 357007 25 29 x 104 347539 1 44 000 ——— 18 000 ——— ——— ——— ——— ——— ——— 12 x 75 13 x 100 17 x 120 18 x 80 29 x 104 30 x 115 3 3 1 1 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— Tubes with Snap-On Caps Polypropylene Orange Yellow Green Blue Natural Polypropylene Natural‡ Polyethylene Open-Top Tubes Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom Round Bottom Conical Round Bottom Round Bottom Conical 5.0 10.0 15.0 15.0 30.0 50.0 ——— ——— ——— ——— ——— ——— * A cap is available for these tubes, but it cannot be used in the JA-18 rotor; for a cap to use when storing samples, order cap 356262. † Can be double-stacked. Force will vary depending on tube position. ‡ With separate cap. .** These adapters fit inside one another to accommodate smaller bottles and tubes. 356969 (qty. of 1) 356975 (qty. of 1) 356962 (qty. of 1) 870329/347539 (qty. of 1) 870331/347539 (qty. of 1) 356963 (qty. of 1) Rotor Replacement Parts 346947 346965 364845 364917 Tie-down Bolt Assembly Rotor Removal Tool Rotor Lid Assembly Tie-down Kit, IRIS Adapters 344497 347539 Beckman Coulter High Performance Centrifuges 1-23 1 www.beckmancoultercentrifugation.com JA-17 JA-17 14 x 50 mL Fixed-Angle Rotor, Aluminum Axis of Rotation Major applications: High-force, large-volume. Pelleting bacteria, cell membranes, and subcellular organelles. rmin (56 mm) 1 rav (90 mm) Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 17 000 39 800 690 14 x 50 mL 29 x 104 mm 1.125 x 4 in 700 mL rmax (123 mm) For use in Avanti J Series centrifuges. 25° No. 369691. JA-17 Fixed-Angle Rotor. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Cap Assemblies Polypropylene 50.0 50.0 357001 361694 6 24 29 x 104 29 x 104 ——— ——— ——— ——— 39 800 39 800 690 690 17 000 17 000 Polycarbonate 50.0 50.0 357000 361693 6 24 29 x 104 29 x 104 ——— ——— ——— ——— 39 800 39 800 690 690 17 000 17 000 Polypropylene 50.0 357003 25 29 x 104 ——— ——— 39 800 690 17 000 Polycarbonate 10.0 50.0 355672 357002 25 25 16 x 80 29 x 104 342327/870329 ——— 1 ——— 32 000 39 800 500 690 17 000 17 000 50.0 357005† 25 29 x 104 ——— ——— 39 800* 690 17 000 Thickwall Polycarbonate 50.0 363647 25 29 x 104 ——— ——— 39 800 690 17 000 Thickwall Polypropylene 50.0 357007 25 29 x 104 ——— ——— 39 800 690 17 000 ——— ——— ——— ——— ——— 12 x 75 13 x 100 16 x 80 18 x 80 29 x 104 1 1 1 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— Bottles with Screw-On Caps Tubes with Snap-On Caps Polypropylene Open-Top Tubes Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom 5.0 8.0 10.0 15.0 30.0 ——— ——— ——— ——— ——— 356970 (qty. of 1) 356976 (qty. of 1) 342327/870329 (qty. of 1) 870329 (qty. of 1) 870331 (qty. of 1) Cap Assembly Replacement Parts Rotor Replacement Parts 356284 358627 878951 811656 369760 364913 392889 961582 † Cap for 357000 and 357001 Tubes Insert for 357000 and 357001 Cap Assembly; order only for use in tubes O-ring for 357000 and 357001 Cap Assembly A maximum of seven tubes can be used, placed in every other rotor hole (tubes placed in adjacent holes will hit one another). O-ring for Rotor Lid O-ring for Rotor Hub Lid Assembly Tie-down Kit Hold-down Knob (used to run filtration tubes without lid) Rotor Supplies 338896 338689 356970 356976 Rotor Removal Tool Adapter Collar for 338896 Rotor Removal Tool Acetal Adapter (qty. 1), fits 12 mm tubes Acetal Adapter (qty. 1), fits 13 mm tubes Adapters 342327 1-24 870329 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JLA-16.250 JLA-16.250 6 x 250 mL Fixed-Angle Rotor, Aluminum 25° Major applications: General purpose, large-volume and multitube processing. Lightweight alternative to conventional 6 × 250 rotors; empty rotor weight is 10.3 kg (22.7 lb). rmin Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 16 000 38 400 1 090 6 × 250 mL 62 × 120 mm 2.5 × 5.5 in 1.5 L 46 mm rav 90 mm rmax 134 mm For use in Avanti J Series centrifuges. Axis of Rotation No. 363930. J-LITE JLA-16.250 Rotor Assembly with Biosafety Lid. No. 363934. Rotor Assembly with Single Lock Lid. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Screw-On Caps Polypropylene 50.0 357003 25 29 x 104 356997 1 32 200 650 16 000 Polycarbonate 50.0 357002 25 29 x 104 356997 1 32 200 660 16 000 Polypropylene 50.0 357001 6 29 x 104 356997 1 32 200 650 16 000 Polycarbonate 50.0 357000 6 29 x 104 356997 1 32 400 660 16 000 Wide-mouth Polycarbonate 250.0 356013 6 62 x 120 —— —— 38 500 1 090 16 000 Wide-mouth Polypropylene 250.0 356011 6 62 x 120 —— —— 38 500 1 070 16 000 Polycarbonate 50.0 363664 25 29 x 104 356997 1 32 100 400 16 000 Polypropylene 50.0 357005 25 29 x 104 356997 1 32 100 400 16 000 4.0 566353 1000 14 x 55 342098 9 2 300 10 700 4 000 ——— ——— ——— ——— ——— 12 x 75 13 x 100 17 x 119 30 x 104 30 x 104 356968 (qty. of 1) 356974 (qty. of 1) 356964 (qty. of 1) 356966 (qty. of 1) 356997 (qty. of 1) 9 8 4 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— Bottles with Cap Assemblies Tubes with Snap-On Caps BioVials Polypropylene Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom Round Bottom Conical Conical Round Bottom 5.0 7.0 15.0 50.0 50.0 ——— ——— ——— ——— ——— Rotor Replacement Parts 363931 363935 893502 893503 Double-locking Lid Assembly Single-locking Lid Assembly Large O-ring for Lid Assembly (5.987 dia.) Small O-ring for Lid Assembly (1.046 dia.) Adapters 342098 356997 356964 Beckman Coulter High Performance Centrifuges 1-25 1 www.beckmancoultercentrifugation.com JA-14.50 JA-14.50 16 x 50 mL Fixed-Angle Rotor, Aluminum Major applications: Pelleting and Density Gradient Separations. Proteins, lysate/tissue homogenates, nucleic acids, cells, viruses and blood. 1 Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 14 000 35 000 787 16 x 50 mL Conical 800 mL 30 x 115 mm For use in Avanti J Series centrifuges. Axis of Rotation No. B19956. JA-14.50 Fixed-Angle Rotor with Single-Locking Lid for 14000 rpm operation. Tubes and bottles not included. No. B19955. JA-14.50 Fixed-Angle Rotor for BioSafe Dual-Locking Lid for 14000 rpm operation. Tubes and bottles not included. Tubes and Bottles Tube Style/Material Bottles with Screw-On Caps Polycarbonate Round Bottom Polypropylene Round Bottom Nominal Part No. Volume per Tube (mL) Quantity Size (mm) / volume (mL) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed 40.0 40.0 357002 357003 25 25 29 x 104/50 B40155 (qty 2) 29 x 104/50 B40155 (qty 2) 1 1 34 520 34 520 563 563 14 000 14 000 Polycarbonate Round Bottom Polypropylene Round Bottom 40.0 40.0 361693 361694 24 24 29 x 104/50 B40155 (qty 2) 29 x 104/50 B40155 (qty 2) 1 1 34 520 34 520 563 563 14 000 14 000 Polycarbonate Round Bottom 10.0 355672 25 16 x 80/10 361703 and B40155 (qty 2) 1 30 900 445 14 000 36.5 36.5 363664 357005 25 25 29 x 104/50 B40155 (qty 2) 29 x 104/50 B40155 (qty 2) 1 1 34 520 34 520 563 563 14 000 14 000 Polycarbonate Round Bottom 35.0 363647 25 29 x 104/50 B40155 (qty 2) 1 34 520 563 14 000 Polypropylene Round Bottom 35.0 357007 25 29 x 104/50 B40155 (qty 2) 1 34 520 563 14 000 Polycarbonate Round Bottom 15.0 342080 100 18 x 100/15 B40157 (qty 2) 1 33 400 665 14 000 Polypropylene Round Bottom 15.0 342081 100 18 x 100/15 B40157 (qty 2) 1 33 400 665 14 000 Polyethylene Round Bottom 15.0 342082 100 18 x 100/15 B40157 (qty 2) 1 33 400 665 14 000 Bottles with Cap Assemblies Tubes with Snap-On Caps Polycarbonate Round Bottom Polypropylene Round Bottom Open-Top Tubes Microfuge Tubes Polypropylene tube 1.5 357448 500 11 x 38/1.5 361705 and B40155 (qty 2) 3 27 000 449 14 000 Polypropylene tube 1.5 356090 500 11 x 38/1.5 361705 and B40155 (qty 2) 3 27 000 449 14 000 Adapters for Non-Beckman Coulter Tubes/Bottlesa** Polypropylene Conical Tube w/ Capb,c,d,e,g Polypropylene Conical Tube w/ Capb,c,d,e,g Polypropylene Conical Tube w/ Tethered Caph Spin Filtration Conicali,j Spin Filtration Conicali,j a. b. c. d. e. g. h. i. j. ** 50.0 15.0 5.0 ——— ——— ——— ——— ——— ——— ——— ——— ——— N/A B40156 (qty 2) B40158 (qty 2) ——— ——— ——— ——— ——— ——— ——— ——— ——— ** ** ** 50.0 15.0 ——— ——— ——— ——— ——— ——— N/A B40156 (qty 2) ——— ——— ——— ——— ——— ——— ** ** Use only the items listed here and observe fill volumes and maximum run speeds. Manufactured by Greiner. Manufactured by BD Falcon. Manufactured by VWR. Manufactured by Corning. Manufactured by NUNC. Manufactured by Eppendorf. Manufactured by Pall. Manufactured by Millipore. Use manufacturer’s recommendations for tube and bottle RCF limits. The corresponding RPM and k factor can be calculated using the equations on pages 1 and 15 of the JA-24.50 rotor manual. Rotor Replacement Parts Supplies B19947 B19952 885501 961696 360998 339558 335148 339555 306812 338765 1-26 Dual-Locking Lid Single-Locking Lid Lid O-Ring (ethylene propylene rubber) Rotor Body O-Ring (ethylene propylene rubber) Rotor removal tool Rotor Cleaning Kit Silicone vacuum grease (1 oz) Solution 555 (1 qt) Spinkote lubricant (2 oz) Stem Lifter (adapter removal) tool Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JA-14 JA-14 6 x 250 mL Fixed-Angle Rotor, Aluminum Major applications: General-purpose, large-volume and multi-tube processing. Adapters permit use of up to 30 each 15-mL tubes and up to 72 each 3-mL tubes. Axis of Rotation rmin (35 mm) rav (86 mm) rmax (137 mm) 25° Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 14 000 30 100 1 764 6 x 250 mL 62 x 120 mm 2.5 x 4.8 in 1.5 L For use in Avanti J Series centrifuges. No. 339247. JA-14§ Fixed-Angle Biosafety Rotor for 14 000 rpm operation. Tubes and Bottles Tube Style/Material Bottles with Screw-On Caps Polypropylene Polycarbonate Conical Polypropylene Conical Polycarbonate Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed 50.0 50.0 230.0 230.0 357003 357002 356989 356987 25 25 6 6 29 x 104 29 x 104 60 x 120 60 x 120 356997 356997 356983 356983 1 1 1 1 30 100 30 100 8 600 8 600 1 764 1 764 6 158 6 158 14 000 14 000 7 500 7 500 50.0 50.0 50.0 250.0 250.0 357001 361694 357000 356013 356011 6 24 6 6 6 29 x 104 29 x 104 29 x 104 62 x 120 62 x 120 356997 356997 356997 ——— ——— 1 1 1 ——— ——— 30 100 30 100 30 100 30 100 30 100 1 764 1 764 1 764 1 764 1 764 14 000 14 000 14 000 14 000 14 000 50.0 50.0 363664 357005 25 25 29 x 104 29 x 104 356997 356997 1 1 30 100 30 100 1 764 1 764 14 000 14 000 50.0 50.0 363647 357007 25 25 29 x 104 29 x 104 356997 356997 1 1 30 100 30 100 1 764 1 764 14 000 14 000 4.0 566353 1000 14 x 55 342098* 9 20 000 ——— 14 000 ——— ——— ——— ——— ——— ——— ——— ——— 12 x 75 13 x 100 17 x 119 29 x 104 30 x 104 30 x 104 53 x 114 60 x 120 9 8 4 1 1 1 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— Bottles with Cap Assemblies Polypropylene Polypropylene Polycarbonate Wide-mouth Polycarbonate Wide-mouth Polypropylene Tubes with Snap-On Caps Polycarbonate Thickwall Polypropylene Open-Top Tubes Thickwall Polycarbonate Thickwall Polypropylene BioVials Polypropylene Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom Round Bottom Conical Round Bottom Conical Round Bottom Round Bottom Conical * 5.0 7.0 15.0 30.0 50.0 50.0 150.0 230.0 ——— ——— ——— ——— ——— ——— ——— ——— 356968 (qty. of 1) 356974 (qty. of 1) 356964 (qty. of 1) 356997/870331 (qty. of 1) 356966 (qty. of 1) 356997 (qty. of 1) 339362 (qty. of 1) 356983 (qty. of 4) Can be double-stacked. Rotor Replacement Parts 346965 870137 870138 811656 360473 Rotor Removal Tool Spring Pin for JA-14 Rotor Lid O-ring for Rotor Lid O-ring for Rotor Body Rotor Lid Assembly (includes Tie-down Kit) Adapters 342098 356983 356997 356995 Beckman Coulter High Performance Centrifuges 1-27 1 www.beckmancoultercentrifugation.com JA-12 Fixed-Angle Rotor, Aluminum Axis of Rotation 1 JA-12 12 x 50 mL Major applications: Pelleting cells, bacteria, or subcellular fractions; phase separations; binding studies. rmin (71 mm) Max. RPM Max. g k Factor Number of Tubes Volume/Size rav (108 mm) 12 000* 23 200 1 244 12 x 50 mL 600 mL 30 x 103 mm (conical) 1.17 x 4 in rmax (144 mm) Rotor Capacity 35° For use in Avanti J Series centrifuges. No. 360992. JA-12§ Fixed-Angle Rotor with Dual-locking Biosafety Lid No. 360993. JA-12 Fixed-Angle Rotor with Single-locking Lid Tubes and Bottles Tube Style/Material Conical* Nominal Volume per Tube (mL) Part No. Quantity 50.0 —— —— Cavity Diameter (mm) —— Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed —— —— 23 200 —— 12 000 1 ——— ——— ——— Adapters for Non-Beckman Coulter Tubes/Bottles Conical * 15.0 Tested using Corning and Falcon 50-mL conical tubes. ——— ——— 17 x 119 393088 (qty. of 1) Rotor Replacement Parts 364846 360991 360999 961696 961697 364919 364922 360998 1-28 Dual-locking Lid Assembly Single-locking Lid Assembly Tie-down Bolt (for use without lid) O-ring for Rotor Body O-ring for Rotor Lid Tie-down Kit (Single) Tie-down Kit (Dual-lock) Rotor Removal Tool Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JLA-10.500 JLA-10.500 6 x 500 mL Fixed-Angle Rotor, Aluminum Axis of Rotation Major applications: Large-volume for initial processing of bacteria or other cells from fermentors, clearing cell debris from homogenates, or pelleting subcellular organelles and protein precipitates. rmin (54 mm) rav (110 mm) rmax (166 mm) Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 10 000 18 600 2 850 6 x 500 mL 69 x 160 mm 2.75 x 6.5 in 3L 20° For use in Avanti J Series centrifuges. No. 369681. J-LITE JLA-10.500 Rotor Assembly. Includes 6 canisters with secondary Biosafety liquid closures. No. 360828. JLA-10.500 canisters with secondary BioSafety liquid closures (set of 2). Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Cap Assemblies Polypropylene 50.0 357001 6 29 x 104 356996 1 12 000 2 840 10 000 Polycarbonate 50.0 500.0 357000 361690 6 6 29 x 104 69x 160 356996 ——— 1 ——— 12 000 18 600 2 840 2 840 10 000 10 000 Polypropylene 500.0 361691 6 69 x 160 ——— ——— 11 900 4 440 8 000 Wide-mouth Polycarbonate 250.0 356013 6 62 x 122 362750** (set of 2) 1 17 700 2 840 10 000 Wide-mouth Polypropylene 250.0 356011 6 62 x 122 362750** (set of 2) 1 17 700 2 840 10 000 Bottles with Screw-On Caps Polypropylene 50.0 357003 25 29 x 104 356996 1 12 000 2 840 10 000 Polycarbonate 50.0 357002 25 29 x 104 356996 1 12 000 2 840 10 000 Polycarbonate 50.0 363664 25 29 x 104 356996 1 12 000 2 840 10 000 Polypropylene 50.0 357005 25 29 x 104 356996 1 12 000 2 840 10 000 Thickwall Polycarbonate 50.0 363647 25 29 x 104 356996 1 12 000 2 840 10 000 Thickwall Polypropylene 50.0 357007 25 29 x 104 356996 1 12 000 2 840 10 000 4.0 566353 1000 14 x 55 362750/342098** 9 ——— ——— 10 000 ——— ——— ——— ——— ——— ——— 12 x 75 13 x 100 17 x 100 17 x 120 25 x 105 29 x 115 356967 (qty. of 1) 356973 (qty. of 1) 356994 (qty. of 1) 356995 (qty. of 1) 359398 (qty. of 1) 356965 (qty. of 1) 11 8 5 5 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— Tubes with Snap-On Caps Open-Top Tubes BioVials Polypropylene Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom Round Bottom Round Bottom Conical Round Bottom Conical 4.0 7.0 15.0 15.0 30.0 50.0 ——— ——— ——— ——— ——— ——— * BioVials require adapters P/N 362750 AND 342098 to run in the JLA-10.500. Two adapters P/N 342098 can be double-stacked inside of one adapter P/N 362750 per rotor cavity if greater capacity is desired. ** These adapters fit inside one another to accommodate smaller bottles and tubes. Rotor Replacement Parts 363334 360828 360842 360848 363335 360834 Rotor Lid Assembly Canister (set of 2 with 2 canister closures) Canister Closure Assembly (1) O-ring for Canister Closure (set of 12) Canister Rack Canister Sleeve Washer Adapters 342098 356996 362750 356995 Beckman Coulter High Performance Centrifuges 1-29 1 www.beckmancoultercentrifugation.com JA-10 JA-10 6 x 500 mL Fixed-Angle Rotor, Aluminum Axis of Rotation Major applications: Large-volume for initial processing of tissue homogenates and other large particles. rmin (38 mm) 1 rav (98 mm) rmax (158 mm) 25° Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 10 000 17 700 3 610 6 x 500 mL 69 x 160 mm 2.75 x 6.5 in 3L For use in Avanti J Series centrifuges. No. 369687. JA-10 Fixed-Angle Rotor for 10 000 rpm operation. Includes carrying handle. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Cap Assemblies Polypropylene 50.0 357001 6 29 x 104 356996 1 12 000 ——— 10 000 Polycarbonate 50.0 357000 6 29 x 104 356996 1 12 000 ——— 10 000 Wide-mouth Polycarbonate 250.0 500.0 356013 355605 6 6 62 x 120 69 x 160 362750** (set of 2) ——— 1 ——— 17 700 17 700 ——— ——— 10 000 10 000 Wide-mouth Polypropylene 250.0 500.0 356011 355607 6 6 62 x 120 69 x 160 362750** (set of 2) ——— 1 ——— 17 700 11 300 ——— ——— 10 000 8 000 50.0 357003 25 29 x 104 356996 1 12 000 ——— 10 000 Polycarbonate 50.0 363664 25 29 x 104 356996 1 12 000 ——— 10 000 Polypropylene 50.0 357005 25 29 x 104 356996 1 12 000 ——— 10 000 Thickwall Polycarbonate 50.0 363647 25 29 x 104 356996 1 12 000 ——— 10 000 Thickwall Polypropylene 50.0 357007 25 29 x 104 356996 1 12 000 ——— 10 000 4.0 566353 1000 14 x 55 362750/342098** 9 ——— ——— 10 000 ——— ——— ——— ——— ——— ——— 12 x 75 13 x 100 17 x 100 17 x 120 25 x 105 29 x 115 356967 (qty. of 1) 356973 (qty. of 1) 356994 (qty. of 1) 356960 (qty. of 1) 359398 (qty. of 1) 356965 (qty. of 1) 11 8 5 5 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— Bottles with Screw-On Caps Polypropylene Tubes with Snap-On Caps Open-Top Tubes BioVials Polypropylene Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom Round Bottom Round Bottom Conical Round Bottom Conical 4.0 7.0 15.0 15.0 30.0 50.0 * ——— ——— ——— ——— ——— ——— BioVials require adapters P/N 362750 AND 342098 to run in the JA-10. Two adapters P/N 342098 can be double-stacked inside of one adapter P/N 362750 per rotor cavity if greater capacity is desired. ** These adapters fit inside one another to accommodate smaller bottles and tubes. Rotor Replacement Parts 334827 870139 811656 364911 392122 Rotor Removal Tool O-ring for Rotor Lid O-ring for Rotor Body Tie-down Kit Rotor Lid Adapters 342098 1-30 356996 362750 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JLA-9.1000 JLA-9.1000 4 x 1000 mL Axis of Rotation Fixed-Angle Rotor, Aluminum 20° Major applications: General purpose, large-volume processing, pelleting of bacteria, subcellular organelles, viruses, and precipitates. Empty rotor weight is 23.9 lb (10.8 kg). 82 mm 134 mm Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 9 000 16 800 2 544 4 x 1000 mL 95 x 191 mm 3.8 x 7.65 in. 4L rmin rav For use in Avanti J Series centrifuges. rmax 185 mm No. 366754. J-LITE JLA-9.1000 Rotor Package. Includes rotor body, lid, carbon fiber canisters, and labware kit 392574. No. 969330. J-LITE JLA-9.1000 Rotor Package. Includes rotor body, lid, carbon fiber canisters, labware kit 392574, and 4 polycarbonate bottles with cap assemblies (two A98812). No. 969331. J-LITE JLA-9.1000 Rotor Package. Includes rotor body, lid, carbon fiber canisters, labware kit 392574, and 4 polypropylene bottles with cap assemblies (two A98813). Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed* Bottles with Cap Assemblies* J-LITE PC-1000† (Polycarbonate) 1000.0 A98812 2 95 x 191 –––––– –––––– 16 800 2 544 9 000 J-LITE PP-1000‡ (Polypropylene) with Polyphenylsufone Cap 1000.0 A98813 2 95 x 191 –––––– –––––– 16 800 2 544 9 000 J-LITE PP-1000‡ (Polypropylene) with Polyphenylene Sulfide Cap 1000.0 B29896 2 95 x 191 –––––– –––––– 16 800 2 544 9 000 Polypropylene 50.0 357001 6 29 x 104 356996/363683** 1 ––––– ––––– 9 000 Polycarbonate 50.0 357000 6 29 x 104 356996/363683** 1 ––––– ––––– 9 000 Wide-mouth Polycarbonate 250.0 500.0 356013 355605 6 6 62 x 120 69 x 160 362750/363683** 363683 1 1 ––––– ––––– ––––– ––––– 9 000 9 000 Wide-mouth Polypropylene 250.0 500.0 356011 355607 6 6 62 x 120 69 x 160 362750/363683** 363683 1 1 ––––– ––––– ––––– ––––– 9 000 8 000 J-LITE PC-1000 (Polycarbonate) 1000.0 366751 2 95 x 191 –––––– –––––– 16 800 2 544 9 000 J-LITE PP-1000 (Polypropylene) 1000.0 A98814 2 95 x 191 –––––– –––––– 16 800 2 544 9 000 J-LITE PP-1000‡ (Polypropylene) 1000.0 B29048 12 95 x 191 –––––– –––––– 16 800 2 544 9 000 50.0 357003 25 29 x 104 356996/363683** 1 ––––– ––––– 9 000 Polycarbonate 50.0 363664 25 29 x 104 356996/363683** 1 ––––– ––––– 9 000 Polypropylene 50.0 357005 25 29 x 104 356996/363683** 1 ––––– ––––– 9 000 Bottles Only Bottles with Screw-On Caps Polypropylene Tubes with Snap-On Caps * Bottle assemblies include cap/closure. The cap/closure serves the dual purpose of sealing the bottle and providing a secondary seal on the carbon-fiber canister to minimize sample loss resulting from bottle leak or failure. † PC-1000 must be run with cap/closure; minimum fill volume is 500 mL. ‡ PP-1000 must be run with cap/closure; minimum fill volume is 1000 mL. ** These adapters fit inside one another to accommodate smaller bottles and tubes. Patented HarvestLine System Liners Disposable liners provide easy-to-use, low-cost sample containment, and storage Adapters 356996 362750 342098 Continued on next page. Beckman Coulter High Performance Centrifuges 1-31 1 www.beckmancoultercentrifugation.com JLA-9.1000 (continued) JLA-9.1000 4 x 1000 mL 1 Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed* Open-Top Tubes Thickwall Polycarbonate 50.0 363647 25 29 x 104 356996/363683** 1 ––––– ––––– 9 000 Thickwall Polypropylene 50.0 357007 25 29 x 104 356996/363683** 1 ––––– ––––– 9 000 4.0 566353 1000 1 ––––– ––––– 9 000 BioVials Polypropylene 14 x 55 342098/362750/363683** ** These adapters fit inside one another to accommodate smaller bottles and tubes. Labware Kit Part Number 392574 Rotor Replacement Parts Includes: 1 ea. 974627 Bottle Rack (holds 6 bottles) 1 ea. 363646 Spatula 1 ea. 366770 Tool Kit 363583 363686 363601 B10317 B29894 Accessories 974627 363646 A99028 B29895 393898 366749 366770 366772 369264 369256 Bottle Rack (holds 6 bottles for easy transport) Spatula Polyphenylsufone Cap/Closure Assembly (set of 2) (Includes cap/closure, O-ring, plug, and plug O-ring) Polyphenylene Sulfide Cap/Closure Assembly (set of 2) (Includes cap/closure, O-ring, plug, and plug O-ring) Plug Assembly, AutoVent Polycarbonate (set of 2) Plug Assembly, AutoVent polyetherimide (PEI)(set of 2) Tool Kit (includes one bottle grip and one wrench) Polytetrafluoroethylene (PTFE) Spray HarvestLine System Liner Kit (Includes 369256 one-liter bottle liners (qty 120), 368740 filling rack, 977472 funnel, and 369267 instructional CD.) HarvestLine System Liners Fits JLA-8.1000 or JLA-9.1000 one-liter bottles (qty. 120). B10319 B10320 Rotor Lid Assembly J-LITE 1000 Removable Canister (set of 2) Canister Sleeve Washer (set of 6) Polyphenylsufone Cap/Closure Replacement Assembly (set of 6) Polyphenylene Sulfide Cap/Closure Replacement Assembly (set of 6) Cap/Closure Replacement O-rings (set of 6) AutoVent Plug Replacement O-rings (set of 6) Includes six large plug O-rings and six AutoVent plug O-rings. Adapters 356996 1-32 362750 342098 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JLA-8.1000 JLA-8.1000 6 x 1000 mL Fixed-Angle Rotor, Aluminum 20° Axis of Rotation 119 mm 171 mm 222.8 mm Major applications: General purpose, large-volume processing, pelleting of bacteria, cell organelles, viruses, and precipitates. Empty rotor weight is 16.8 kg (37 lb). rmin rav rmax Max. RPM Max. g k Factor Number of Bottles Volume/Size Rotor Capacity 8 000 15 970 2 482 6 x 1000 mL 95 x 191 mm 3.8 x 7.65 in. 6L For use in Avanti J-26 XP Series centrifuges and Avanti J-HC. No. 363688. J-LITE JLA-8.1000 Rotor Package . Includes rotor body, Biosafety lid, carbon fiber canisters, and labware kit 392574. No. 969328. J-LITE JLA-8.1000 Rotor Package. Includes rotor body, lid, carbon fiber canisters, labware kit 392574, and 6 polycarbonate bottles with cap assemblies (three A98812). No. 969329. J-LITE JLA-8.1000 Rotor Package. Includes rotor body, lid, carbon fiber canisters, labware kit 392574, and 6 polypropylene bottles with cap assemblies (three A98813). Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Cap Assemblies* J-LITE PC-1000† (Polycarbonate) 1000.0 A98812 2 95 x 191 –––––– –––––– 15 970 2 482 8 000 J-LITE PP-1000‡ (Polypropylene) with Polyphenylsufone Cap 1000.0 A98813 2 95 x 191 –––––– –––––– 15 970 2 482 8 000 J-LITE PP-1000 (Polypropylene) with Polyphenylene Sulfide Cap 1000.0 B29896 2 95 x 191 –––––– –––––– 15 970 2 482 8 000 Polypropylene 50.0 357001 6 29 x 104 356996/363683** 1 ––––– ––––– 8 000 Polycarbonate 50.0 357000 6 29 x 104 356996/363683** 1 ––––– ––––– 8 000 Wide-mouth Polycarbonate 250.0 500.0 356013 355605 6 6 62 x 120 69 x 160 362750/363683** 363683 1 1 ––––– ––––– ––––– ––––– 8 000 8 000 Wide-mouth Polypropylene 250.0 500.0 356011 355607 6 6 62 x 120 69 x 160 362750/363683** 363683 1 1 ––––– ––––– ––––– ––––– 8 000 8 000 J-LITE PC-1000 (Polycarbonate) 1000.0 366751 2 95 x 191 –––––– –––––– 15 970 2 482 8 000 J-LITE PP-1000 (Polypropylene) 1000.0 A98814 2 95 x 191 –––––– –––––– 15 970 2 482 8 000 J-LITE PP-1000 (Polypropylene) 1000.0 B29048 12 95 x 191 –––––– –––––– 15 970 2 482 8 000 50.0 357003 25 29 x 104 356996/363683** 1 ––––– ––––– 8 000 Polypropylene 50.0 363664 25 29 x 104 356996/363683** 1 ––––– ––––– 8 000 Polypropylene 50.0 357005 25 29 x 104 356996/363683** 1 ––––– ––––– 8 000 Bottles Only Bottles with Screw-On Caps Polypropylene Tubes with Snap-On Caps Patented HarvestLine System Liners * Bottle assemblies include cap/closure. The cap/closure serves the dual purpose of sealing the bottle and providing a secondary seal on the carbon-fiber canister to minimize sample loss resulting from bottle leak or failure. † PC-1000 must be run with cap/closure; minimum fill volume is 500 mL. ‡ PP-1000 must be run with cap/closure; minimum fill volume is 1 000 mL. ** These adapters fit inside one another to accommodate smaller bottles and tubes. Disposable liners provide easy-to-use, low-cost sample containment, and storage Adapters 356996 362750 342098 Continued on next page. Beckman Coulter High Performance Centrifuges 1-33 1 www.beckmancoultercentrifugation.com JLA-8.1000 (continued) JLA-8.1000 6 x 1000 mL 1 Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Open-Top Tubes Thickwall Polycarbonate 50.0 363647 25 29 x 104 356996/363683** 1 ––––– ––––– 8 000 Thickwall Polypropylene 50.0 357007 25 29 x 104 356996/363683** 1 ––––– ––––– 8 000 4.0 566353 1000 14 x 55 342098/362750/363683** 1 ––––– ––––– 9 000 BioVials Polypropylene ** These adapters fit inside one another to accommodate smaller bottles and tubes. Labware Kit Part Number 392574 Includes: 1 ea. 974627 Bottle Rack (holds 6 bottles) 1 ea. 363646 Spatula 1 ea. 366770 Tool Kit Accessories 974627 363663 363646 A99028 B29895 393898 366749 366770 366772 369264 369256 Bottle Rack (holds 6 bottles for easy transport) Bottle Rack (holds 3 bottles for easy transport) Spatula Polyphenylsufone Cap/Closure Assembly (set of 2) (Includes cap/closure, O-ring, plug, and plug O-ring) Pohlyphenylene Sulfide Cap/Closure Assembly (set of 2) (Includes cap/closure, O-ring, plug, and plug O-ring) Plug Assembly, AutoVent Polycarbonate (set of 2) Plug Assembly, AutoVent polyetherimide (PEI) (set of 2) Tool Kit (includes one bottle grip and one wrench) Polytetrafluoroethylene (PTFE) Spray HarvestLine System Liner Kit (includes 369256 one-liter bottle liners (qty. 120), P/N 368740 filling rack, P/N 977472 funnel, and P/N 369267 instructional CD.) HarvestLine System Liners (fits JLA-8.1000 or JLA-9.1000 one-liter bottles (qty. 120). Rotor Replacement Parts 363563 363686 363601 B10317 B29894 B10319 B10320 Rotor Lid Assembly J-LITE Removable Canister (set of 2) Canister Sleeve Washer (set of 6) Polyphenylsufone Cap/Closure Replacement Assembly (set of 6) Polyphenylene Sulfide Cap/Closure Replacement Assembly (set of 6) Cap/Closure Replacement O-rings (set of 6) AutoVent Plug Replacment O-rings (set of 6) (Includes six large plug O-rings and six AutoVent plug O-rings) Adapters 356996 1-34 362750 342098 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-24.38 JS-24.38 6 x 38.5 mL Swinging-Bucket Rotor, Aluminum, Titanium Buckets Major applications: Harvesting bacteria, processing tissue homogenates, subcellular particulates, routine pelleting such as precipitates and phase separations. Axis of Rotation rmax (161.0 mm) rav (118.2 mm) rmin (75.3 mm) Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 24 000* 103 900 334 6 × 38.5 mL 25 × 89 mm 1 × 3.5 in 231 mL For use in Avanti J Series centrifuges (except Avanti J-E). No. 360743. JS-24.38 Swinging-Bucket Rotor, with six 38.5-mL buckets. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed* Quick-Seal Bell-Top Tubes Polypropylene 15.0 27.0 33.0 343664 343665 344623 50 50 50 25 x 38 25 x 64 25 x 83 355536† 355536† 355536† 1 1 1 103 900 103 900 103 900 167 260 317 24 000 24 000 24 000 8.5 358652 50 25 x 38 358156 355536† 1 103 900 167 24 000 Polypropylene 38.5 326823 50 25 x 89 —— —— 103 900 334 24 000 konical Polypropylene 25.0 30.0 358125 358126 50 50 25 x 76 25 x 89 358156 358156 1 1 95 500 103 900 297 334 24 000 24 000 konical Polypropylene Open-Top Tubes Thickwall Polypropylene 32.0 355642 25 25 x 89 —— —— 103 900 334 24 000 Thickwall Polycarbonate 32.0 355631 25 25 x 89 —— —— 103 900 334 24 000 Ultra-Clear 38.5 344058 50 25 x 89 —— —— 103 900 334 24 000 * † Reaches 24 000 rpm in the Avanti J-30I centrifuge only. Not recommended for use in Avanti J-25 Series (max. speed 10 000 rpm), or Avanti J-26 XP Series (max. speed 10 000 rpm). Incompatible with all J2 Series. Modified polyphenylene oxide Floating Spacer. Rotor Replacement Parts 362397 812715 362785 Bucket Set - 38 mL (set of 6 with caps and O-rings) Bucket O-ring Rotor Stand Adapters 355536 358156 Beckman Coulter High Performance Centrifuges 1-35 1 www.beckmancoultercentrifugation.com JS-24.15 JS-24.15 6 x 15 mL Swinging-Bucket Rotor, Aluminum, Titanium Buckets Major applications: Harvesting bacteria, processing tissue homogenates, subcellular particulates, routine pelleting such as precipitates and phase separations. Axis of Rotation rmax (171.3 mm) rav (125.2 mm) 1 rmin (79 mm) Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 24 000* 110 500 376 6 × 15 mL 16 × 96 mm 0.625 × 3.75 in 90 mL For use in Avanti J Series centrifuges (except Avanti J-E). No. 362396. JS-24.15 Swinging-Bucket Rotor with six 15-mL buckets. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed* 355579† 355579† 355579† 355579† 1 1 1 1 110 500 110 500 110 500 110 500 193 215 261 293 24 000 24 000 24 000 24 000 Quick-Seal Bell-Top Tubes Polypropylene 4.2 6.3 8.0 10.0 356562 345830 344621 344622 50 50 50 50 16 x 38 16 x 45 16 x 58 16 x 67 Open-Top Tubes Polypropylene 15.0 361707 50 16 x 96 —— —— 110 500 376 24 000 konical Polypropylene 12.5 361708 50 16 x 93 358155 1 108 500 368 24 000 Ultra-Clear 15.0 361706 50 16 x 96 —— —— 110 500 376 24 000 * † Reaches 24 000 rpm in the Avanti J-30I centrifuge only. Not recommended for use in Avanti J-25 Series (max speed 10 000 rpm), or Avanti J-26 XP Series (max. speed 10 000 rpm). Incompatible with all J2 Series. Modified polyphenylene oxide Floating Spacer. Rotor Replacement Parts 362398 815472 362785 364802 Bucket Set - 15 mL (set of 6 with caps and O-rings) Bucket O-ring Rotor Stand Rotor and Adapter Assembly Adapters 358155 1-36 355579 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-13.1 JS-13.1 6 x 50 mL Swinging-Bucket Rotor, Aluminum Major applications: Harvesting bacteria, processing tissue homogenates, separating cell particulates. Isolation of cell membrane using density gradients. Axis of Rotation rmin (41 mm) rav (91 mm) rmax (140 mm) Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 13 000 26 500 1 841 6 x 50 mL 29 x 105 mm 1.125 x 4 in 300 mL 90° For use in Avanti J Series centrifuges. No. 346963. JS-13.1 Swinging-Bucket Rotor for 13 000 rpm operation. Includes carrying handle. Tubes and bottles not included. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Screw-On Caps Polypropylene 50.0 357003 25 29 x 104 ——— ——— 26 500 1 840 13 000 Polycarbonate 10.0 50.0 355672 357002 25 25 16 x 80 29 x 104 342327/870329 ——— 1 ——— 26 500 26 500 1 840 1 840 13 000 13 000 Polypropylene 50.0 357005† 25 29 x 104 ——— ——— 26 500 1 840 13 000 Polycarbonate 50.0 363664† 25 29 x 104 ——— ——— 26 500 1 840 13 000 Polyethylene 1.8 340196 500 11 x 39 344497* 3 26 500 1 840 13 000 Tubes with Snap-On Caps Polypropylene Natural 1.5 357448 500 11 x 38 344497* 3 26 500 1 840 13 000 Polypropylene Orange Yellow Green Blue Natural 1.5 1.5 1.5 1.5 1.5 356094 356093 356092 356091 356090 500 500 500 500 500 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 344497* 344497* 344497* 344497* 344497* 3 3 3 3 3 26 500 26 500 26 500 26 500 26 500 1 840 1 840 1 840 1 840 1 840 13 000 13 000 13 000 13 000 13 000 10.0 355630 25 16 x 76 342327/870329 4/1 8 000 ——— 13 000 ——— ——— ——— ——— 12 x 75 13 x 100 18 x 80 29 x 104 356970 (qty. of 1) 356976 (qty. of 1) 870329 (qty. of 1) 870331 (qty. of 1) 1 1 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— Open-Top Tubes Thickwall Polycarbonate Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom * † 5.0 8.0 15.0 30.0 ——— ——— ——— ——— Can be double-stacked. Force will vary depending on tube position. Cannot be run with caps in this rotor. Rotor Replacement Parts 346965 346976 364862 364921 346979 346964 Rotor Removal Tool Buckets (set of 6) Rotor Tie-down Assembly Tie-down Kit Windshield Bowl Trim Rotor Lid Assembly Adapters 342327 344497 870329 Beckman Coulter High Performance Centrifuges 1-37 1 www.beckmancoultercentrifugation.com JS-7.5 Swinging-Bucket Rotor, Aluminum Axis of Rotation Major applications: Initial processing of cells and removal of cell debris from culture media. rmin (51 mm) rav (108 mm) 1 JS-7.5 4 x 250 mL rmax (165 mm) Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 7 500 10 400 5 287 4 x 250 mL 62 x 136 mm 2.5 x 5.5 in 1L 90° For use in Avanti J Series centrifuges (except Avanti J-E). No. 336380. JS-7.5 Swinging-Bucket Rotor for 7 500 rpm operation. Includes four 250-mL buckets. Multitube carriers available separately. Tubes and bottles not included. No. 362212. JS-7.5 Rotor without buckets. Multitube Carriers For added versatility, three Multitube Carriers are available for the JS-7.5 Rotor. These Carriers require no adapters to accommodate 50-mL conical tubes, 50-mL round-bottom tubes, and 5-mL round-bottom tubes. Multitube carriers are interchangeable with the buckets of the JS-7.5 Rotor. 50-mL Conical Tube Carrier No. 362213. Multitube Carrier for 50-mL conical tubes. Holds three tubes per carrier for maximum rotor capacity of 12 × 50-mL conical tubes. Set of two. Major applications: General-purpose pelleting (especially of cells), as well as nucleic acid precipitations and isolation of mononuclear cells using Ficoll-Paque. Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 7 500 10 580 4 140 12 x 50 mL (conical) 29 x 103 mm 1.125 x 4 in 600 mL Major applications: General-purpose centrifugation. 50-mL Round-Bottom Tube Carrier No. 362214. Multitube Carrier for 50-mL roundbottom tubes. Holds four tubes per carrier for maximum rotor capacity of 16 × 50-mL tubes. Set of two. Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 7 500 10 080 3 959 16 x 50 mL 29 x 104 mm 1.125 x 4 in 800 mL Tubes for 250-mL Bucket Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Screw-On Caps Polycarbonate 250.0 355673 6 62 x 136 336389 1 10 400 5 290 7 500 Polypropylene 50.0 357003 25 29 x 104 356997 1 9 000 ——— 7 500 50.0 50.0 355603 357000 6 6 16 x 76 29 x 104 356997 356997 1 1 9 000 9 000 ——— ——— 7 500 7 500 Conical Polycarbonate 230.0 356987 6 62 x 141 356983 1 10 400 5 290 7 500 Wide-mouth Polycarbonate 250.0 356013 6 62 x 120 ——— ——— 10 400 5 290 7 500 Conical Polypropylene 230.0 356989 6 62 x 141 356983 1 10 400 5 290 7 500 Wide-mouth Polypropylene 250.0 356011 6 62 x 120 ——— ——— 10 400 5 290 7 500 Bottles with Cap Assemblies Polycarbonate 1-38 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-7.5 (continued) JS-7.5 4 x 250 mL Tubes for 250-mL Bucket (continued) Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Tubes with Snap-On Caps Polycarbonate 50.0 363664 25 29 x 104 356997 1 9 000 ——— 7 500 Polypropylene 50.0 357005 25 29 x 104 356997 1 9 000 ——— 7 500 Polycarbonate (Graduated) 50.0 363647 25 29 x 104 356997 ——— 10 080 5 290 7 500 Polypropylene (Graduated) 50.0 357007 25 29 x 104 356997 4 9 000 ——— 7 500 4.0 566353 1000 14 x 55 342098* 9 ——— ——— 7 500 Quantity Size (mm) Required Adapters Tubes per Adapter g-Force k Factor Open Top Tubes BioVials Polypropylene Tubes for 4-place Carrier Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Maximum Speed Bottles with Screw-On Caps Polypropylene 50.0 357003 25 29 x 104 356997 1 10 400 ——— 7 500 Polycarbonate 50.0 357002 25 29 x 104 356997 1 10 400 ——— 7 500 Polycarbonate 50.0 363664** 25 29 x 104 ——— ——— 10 400 ——— 7 500 Polypropylene 50.0 357005** 25 29 x 104 ——— ——— 10 400 ——— 7 500 50.0 363647 25 29 x 104 ——— ——— 10 400 ——— 7 500 356968 356974 356964 356995 870329 870331 356997/ 870331 356996 356997 339362 9 8 4 5 1 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— 1 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— Tubes with Snap Caps Open-Top Tubes Thickwall Polycarbonate Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom Round Bottom Conical Round Bottom Round Bottom Round Bottom Round Bottom 5.0 7.0 15.0 15.0 15.0 30.0 30.0 ——— ——— ——— ——— ——— ——— ——— 1 1 1 1 1 1 1 12 x 75 13 x 199 17 x 118 18 x 98 18 x 80 29 x 104 29 x 103 Conical Round Bottom Round Bottom 50.0 50.0 150.0 ——— ——— ——— 1 1 1 30 x 104 30 x 104 53 x ___ * Adapter 342098 can be double-stacked to increase rotor capacity. ** See Rotor Manual for instructions on positioning these tubes in the carrier. Rotor Replacement Parts 885367 816952 362216 362212 Retaining Ring for Rotor Knob Shaft if purchased after 1/1/81. If purchased before 1/1/81, use 885367 and 336747. Polyethylene Rotor Foot 250-mL Buckets (set of 2) JS-7.5 Rotor without carriers or buckets 364920 362213 362214 362215 Tie-down Kit 3 x 50 mL Conical Multitube Carriers (set of 2) 4 x 50 mL Round-bottom Multitube Carriers (set of 2) 24 x 5 mL Round-bottom Multitube Carriers (set of 2) Adapters 336389 342098 356964 356983 Beckman Coulter High Performance Centrifuges 356997 1-39 1 www.beckmancoultercentrifugation.com JS-5.9 JS-5.9 10 Microplates Swinging-Bucket Rotor, Aluminum Major applications: High-throughput processing (DNA or RNA kits), serial dilution of small volumes. 1 rmin 138.6 mm rav 153.4 mm rmax 168.5 mm Max. RPM Max. g Rotor Capacity Approximate Accel/Decel Time (sec) 5 900 6 570 10 Microplates 47/49 For use in Avanti J-26S Series and Avanti J-30I centrifuges. Axis of Rotation No. 369331. JS-5.9 Swinging-Bucket Rotor Assembly. Two-place rotor with removable aluminum swinging buckets (set of two), microplate carriers (set of two), support pad for microplates (set of four), and tie-down. Microplates Plate or Tube Style/Material Nominal Volume per Well Multiwell Plate, Polystyrene, Nonsterile 300 µL 609844 100 96 wells —— —— 5 900 1 mL 267001 24 96 wells —— —— 5 900 Deep-well Plate, Polystyrene, Nonsterile* Part No. Quantity No. of Wells g-Force k Factor Maximum Speed Deep-well Plate, Polystyrene, Sterile* 1 mL 267004 24 96 wells —— —— 5 900 Deep-well Plate, Polypropylene, Nonsterile 1 mL 267006 24 96 wells —— —— 5 900 Deep-well Plate, Polypropylene, Sterile 1 mL 267007 24 96 wells —— —— 5 900 Square-well Plate, Polypropylene 2 mL 140504 24 96 wells —— —— 5 900 Accessories Rotor Replacement Parts 267002 267005 538619 368957 538618 339558 339555 339379 977212 368919 368920 Cap Strip, Nonsterile† (pkg. of 12) Cap Strip, Sterile† (pkg. of 12) Aluminum Foil Lid‡ (pkg. of 100) Support Pad for Microplates (set of 4) Rubber Roller, 4-inch, for sealing microplate lids Rotor Cleaning Kit Beckman Coulter Solution 555 (1 qt) Rotor Cleaning Brush Paint On Graphite Lubricant (1/2 oz) Bucket (set of 2) Microplate Carrier (set of 2) * Do not stack these plates. † Caps are optional. ‡ Requires 4-inch soft rubber roller (538618) for installation. 1-40 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-5.3 AllSpin ◊ JS-5.3 AllSpin 24 Microplates Swinging-Bucket Rotor, Anodized Aluminum Major applications: Rapid sedimentation of protein precipitates, large particles, cells, and cell debris. It can be used for binding studies and separating serum from whole blood. rmin rav rmax 179.6 mm 194.8 mm Axis of Rotation rmin rav 92.7 mm 155.6 mm rmax Max. RPM Max. g Number of Tubes Volume Rotor Capacity 5 300 5 300 6 870 6 130 4 x 500 mL 24 microplates 8 deep-well microplates 2L 2L 164.3 mm 218.4 mm For use in Avanti J-E and J-26S centrifuges only. Axis of Rotation No. 368690. JS-5.3 Swinging-Bucket Rotor. Four-place rotor with anodized aluminum buckets designed for use with adapters to accommodate a wide range of tubes and bottles. Rotor buckets are interchangeable with microplate carriers. Includes tie-down knob. No. 969314. JS-5.3 Swinging-Bucket Rotor Package. Includes rotor, buckets, tie-down knob, and microplate carrier kit (368914). Microplate Carrier Kit No. 368914. Microplate Carrier Kit. Includes 4 carriers (368905) and 4 support pads (369382). Replacement Parts for Microplate Carriers 369382 368914 368417§ 368706 Support Pads (set of 4) Microplate Carrier (set of 4) Aeroseal Covers for JS-5.3 AllSpin Rotor (set of 2) Bucket Upgrade Kit (set of 4 blue buckets)*** Tubes and Bottles Size Required Adapter (pkg. 4) Adapter Color Tubes per Adapter Maximum Speed g-Force* 5 mL round, 13 mm diameter, variable lengths 392071 Beige 33 6 145 5 300 10 mL round, 16 mm diameter, variable lengths 392072 Purple 24 6 145 5 300 15 mL round, 17 mm diameter, variable lengths 392073 Red 20 6 145 5 300 15 mL conical, 17 mm diameter, variable lengths 392075 Green 18 6 425† 5 300 50 mL round, 29 mm diameter, variable lengths 392074 Yellow 8 6 145 5 300 50 mL conical, 30 × 115 mm 392076 Black 7 6 480† 5 300 250 mL round/230 mL conical 392077 Yellow 1 6 670 5 300‡ 250 mL conical, 60 × 172 mm 392079 Orange 1 6 870 5 300 500 mL conical £ 392078 Blue 1 6 870 5 300 15 mL conical 356964 (each) Yellow 4 6 670 5 300** 50 mL conical 356966 (each) Yellow 1 6 670 5 300** * Maximum RCF and speed for adapters. Use manufacturers’ recommendations for tube and bottle limits. ** Use this adapter inside the 250-mL adapter (392077) *** Rotors with black buckets require Bucket Upgrade Kit 368706 † Maximum RCF for labware tested in this adapter is 4 000 × g. Use manufacturers’ recommendations for max g-force. ‡ Requires a cushion (356983) to be placed at bottom of adapter. ◊ £ When used with optional Aeroseal Covers, P/N 368417. Cannot be used with bucket cover Continued on next page. Adapters 392071 392072 392073 392074 Beckman Coulter High Performance Centrifuges 392075 392076 392079 392077 392078 356966 356964 1-41 1 www.beckmancoultercentrifugation.com JS-5.3 AllSpin (continued) JS-5.3 AllSpin 4 x 500 mL 1 Description Nominal Volume per Well Part No. Quantity Maximum Speed Accessory Description* Part No. Quantity 300 µL 609844 100 5 300 Cap Strip, Nonsterile† Cap Strip, Sterile† Aluminum Foil Lid‡ 267002 267005 538619 12 12 100 Deep-Well Polystyrene Plate, 96-Well, Nonsterile 1 mL 267001 24 5 300 Cap Strip, Nonsterile Cap Strip, Sterile Aluminum Foil Lid 267002 267005 538619 12 12 100 Deep-Well Polystyrene Plate, 96-Well, Sterile 1 mL 267004 24 5 300 Cap Strip, Nonsterile Cap Strip, Sterile Aluminum Foil Lid 267002 267005 538619 12 12 100 Deep-Well Polypropylene Plate, 96-Well, Nonsterile 1 mL 267006 24 5 300 Cap Strip, Nonsterile Cap Strip, Sterile Aluminum Foil Lid 267002 267005 538619 12 12 100 Deep-Well Polypropylene Plate, 96-Well, Sterile 1 mL 267007 24 5 300 Cap Strip, Nonsterile Cap Strip, Sterile Aluminum Foil Lid 267002 267005 538619 12 12 100 Square-Well Polystyrene Plate, 2 mL 140504 24 5 300 Aluminum Foil Lid 538619 100 Microplates Multiwell Polystyrene Plate, 96-Well, Nonsterile * † ‡ When stacking polypropylene multiwell plates, place a support pad (369382) beneath the bottom plate and a cap strip between the plates to prevent breakage during centrifugation. Also use the support pad beneath all polystyrene deep-well plates. Caps are optional. Requires 4-inch soft-rubber roller (538618) for installation. Rotor Replacement Parts 368690 368410 368706 368914 JS-5.3 rotor assembly Rotor tie-down knob Bucket (set of 4) Microplate carrier kit Contains: 368905 Microplate carrier (set of 4) 369382 Support pad (set of 4) Rotor Supplies Replacement tube and bottle adapters (set of 2): 368907 Beige (13 mm dia) 368909 Purple (16 mm dia) 368910 Red (17 mm dia) 368911 Yellow (29 mm dia) 368915 Green (15 mL conical) 368916 Black (50 mL conical) 369385 Orange (250 mL conical) 369383 Yellow (250 mL round/230 mL conical) 369384 Blue (500 mL conical) 538618 Rubber Roller, 4-in., for sealing foil microplate lids 1-42 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-5.2 * JS-5.2 4 x 1000 mL Swinging-Bucket Rotor (Windshielded), Anodized Aluminum Axis of Rotation rmin (86 mm) rav (156 mm) Max. RPM Max. g Rotor Capacity Approximate Accel/Decel Time (min:sec) 5 200 6 840 4 Liters, 4 Blood Bags, 12 Microplates, 148 RIA-Tubes 2:30/3:00 rmax (226 mm) For use in J6-MI centrifuge. No. 339087. JS-5.2§ Swinging-Bucket Biosafety Rotor. Windshielded, four-place rotor with aluminum rotor yoke and removable aluminum swinging buckets. Buckets are interchangeable with Microplate Carriers for spinning microtiter plates and MiniTube Racks. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Screw-On Caps Polycarbonate 10.0 50.0 250.0 500.0 750.0 1000.0 355672 357002 355673 355664 358299 355675 25 25 6 6 6 6 16 x 80 29 x 104 62 x 136 69 x 160 96 x 130 97 x 167 341977 339103 339108 339109 356096 (set of 6) 356096 (set of 6) 19 7 1 1 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— 5 200 5 200 5 200 5 200 5 200 5 200 Polypropylene 50.0 100.0 500.0 750.0 1000.0 357003 355624 355665 356855 355676 25 6 6 6 6 29 x 104 38 x 102 69 x 159 96 x 130 97 x 167 339103 339104 339109 356096 (set of 6) 356096 (set of 6) 7 2 1 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— 5 200 5 200 5 200 5 200 5 200 Polypropylene 50.0 361694 6 29 x 104 356997 1 ——— ——— 5 200 Polypropylene 50.0 357001 6 29 x 104 339103 7 ——— ——— 5 200 Polycarbonate 50.0 70.0 357000 355620 6 6 29 x 104 38 x 102 339103 339104 7 2 ——— ——— ——— ——— 5 200 5 200 Wide-mouth Polycarbonate 250.0 500.0 356013 355605 6 6 62 x 120 69 x 160 339108 339109 1 1 ——— ——— ——— ——— 5 200 5 200 Wide-mouth Polypropylene 250.0 500.0 356011 355607 6 6 62 x 120 69 x 160 339108 339109 1 1 ——— ——— ——— ——— 5 200 5 200 70.0 500.0 355655 355649 6 6 ——— ——— ——— ——— 5 200 5 200 Bottles with Cap Assemblies Bottles with Screw-On Caps Polycarbonate 38 x 102 69 x 160 339104 339109 2 1 Wide-mouth Polycarbonate 250.0 358275 25 62 x 122 339108 1 ——— ——— 5 200 Polypropylene 100.0 500.0 355626 355650 6 6 38 x 102 69 x 159 339104 339109 2 1 ——— ——— ——— ——— 5 200 5 200 Wide-mouth Polypropylene 250.0 358326 25 62 x 122 339108 1 ——— ——— 5 200 Conical Polycarbonate 230.0 356987 6 60 x 120 356983/339108** 1 ——— ——— 5 200 Conical Polypropylene 230.0 356989 6 60 x 120 356983/339108** 1 ——— ——— 5 200 * When used with optional Aeroseal Covers, P/N 343686. ** These adapters fit inside one another to accommodate smaller bottles and tubes. § This rotor was tested to demonstrate containment of microbiological aerosols under normal operating conditions of the associated Beckman Coulter centrifuge, when used and maintained as instructed. Validation of microbiological containment was done at an independent, third-party facility (CAMR, Porton Down, UK or USAMRIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and, thus, containment. Continued on next page. Adapters 339100 339101 339102 339103 339104 Beckman Coulter High Performance Centrifuges 339108 339109 341977 354511 356096 356983 1-43 1 www.beckmancoultercentrifugation.com JS-5.2 (continued) JS-5.2 4 x 1000 mL 1 Tubes and Bottles (continued) Tube Style/Material Nominal Volume per Tube (mL) Part No. Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339100/354511** 26 26 26 26 26 26 26 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— 5 200 5 200 5 200 5 200 5 200 5 200 5 200 Tubes with Snap-On Caps Polypropylene Natural Orange Yellow Green Blue Natural Natural* 1.5 1.5 1.5 1.5 1.5 1.5 1.5 357448 356094 356093 356092 356091 356090 343169 500 500 500 500 500 500 500 Polyethylene 1.8 340196 500 11 x 39 339100/354511** 26 ——— ——— 5 200 Polycarbonate 50.0 363664 25 29 x 104 339103 7 ——— ——— 5 200 Polypropylene 50.0 357005 25 29 x 104 339103 7 ——— ——— 5 200 Thickwall Polypropylene 10.0 355640 25 16 x 76 341977 19 ——— ——— 5 200 Thickwall Polycarbonate 10.0 15.0 50.0 355630 342080 363647 25 100 25 16 x 76 18 x 98 29 x 104 341977 339102 356997 19 14 7 ——— ——— ——— ——— ——— ——— 5 200 5 200 5 200 Thickwall Polyethylene 15.0 342081 100 18 x 98 339102 14 ——— ——— 5 200 Thickwall Polypropylene 15.0 50.0 342082 357007 100 25 18 x 98 29 x 104 339102 339103 14 7 ——— ——— ——— ——— 5 200 5 200 4.0 566353 1000 14 x 55 339101 24 ——— ——— 5 200 339119 (qty. of 1) (double stacked adapter) 339100 (qty. of 1) 339101 (qty. of 1) 341977 (qty. of 1) 356995 (qty. of 1) 339102 (qty. of 1) 345386 (qty. of 1) 341794 (qty. of 1) 19 ——— ——— ——— 37 24 19 5 14 4 4 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— Open-Top Tubes BioVials Polypropylene Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom 3.0 & 5.0 ——— ——— 12 x 75 Round Bottom Round Bottom Round Bottom Conical Round Bottom Conical Round Bottom 3.0 & 5.0 10.0 12.0 15.0 20.0 50.0 50.0 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— 12 x 133 14 x 133 16 x 133 17 x 119 18 x 133 30 x 136 35 x 136 * Cap separate. ** These adapters fit inside one another to accommodate smaller bottles and tubes. Adapters 339100 1-44 339101 339102 339103 339104 339108 339109 341977 354511 356096 356983 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-5.2 (continued) JS-5.2 4 x 1000 mL 1 Blood-Bag Cups No. 339127. Yellow cup with inner diameter of 88 mm for single- and double-packs. Set of four. No. 339129. Red cup with inner diameter of 98 mm for triple- and quad-packs. Sold individually. Aeroseal Covers § No. 343686. Cover for round buckets of JS-5.2. Features O-ring seal to provide added aerosolprotection. Transparent so broken tubes can be detected and proper precautions taken before breaking seal. Quantity 1. Microplate Carriers No. 358680. Special carriers, interchangeable with buckets, slip onto yoke of JS-5.2 Rotor. Each carrier holds three microplates for a total capacity of 12 per run. Maximum speed 2 600 rpm (1450 x g). Set of two. § Validation of microbiological containment was done at an independent, third-party facility (CAMR, Porton Down, UK or USAMRIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and, thus, containment. Beckman Coulter High Performance Centrifuges Rotor Supplies 339031 341710 878439 367045 Rotor Tie-down Screw Bucket Set (set of 4) Torquing Bar for Rotor Tie-down Screw Rotor Tie-down Kit for Avanti J-26 XP Series centrifuge 1-45 www.beckmancoultercentrifugation.com JS-5.0 JS-5.0 4 x 2.25 L Swinging-Bucket Rotor, Anodized Aluminum Major applications: Separating bacterial, yeast, and tissue homogenates; harvesting cultures. 1 r min (108 mm) rav (188 mm) rmax (267 mm) Max. RPM Max. g k Factor Number of Containers Rotor Capacity 5 000 7 480 9 171 4 x 2.25 L 9L For use in Avanti J-HC centrifuges. Axis of Rotation No. 367820. JS-5.0 Swinging-Bucket Rotor Assembly with Labware Kit. Four-place rotor with anodized aluminum buckets. Includes 4 cups, 4 cup covers with plugs, 8 red cup gaskets, 4 green liner gaskets, 60 air vent filters, 50 HarvestLine System Liners, 2 cup racks, 1 spatula. Labware Kit No. 368732. Includes 4 cups, 4 cup covers with plugs, 8 red cup gaskets, 4 green liner gaskets, 60 air vent filters, 50 HarvestLine System Liners, 2 cup racks, 1 spatula. Container Assembly No. 368730. Includes 4 cups, 4 covers with plugs, and 4 cup gaskets (369257). HarvestLine System Liners No. 368735. Set of 50 polyethylene system liners (food grade compliant). Rotor Accessories Rotor Replacement Parts 368727 367891 369259 367837 369257 369261 346965 367824 368521 369258 1-46 Rack Spatula (set of 2) Partition (set of 4) Buckets (set of 4) Gaskets, Cup (red, set of 4) Gaskets, Liner (green, set of 4) Rotor Removal Tool Tie-down Bolt Tie-down Tool Plug, cover, set of 4 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-4.3 ** JS-4.3 4 x 750 mL Swinging-Bucket Rotor, Anodized Aluminum Major applications: Rapid sedimentation of protein precipitates, large particles, cells, and cell debris. It can be used for binding studies and separating serum from whole blood. Axis of Rotation rmin (86 mm) rav (145 mm) rmax (204 mm) Max. RPM Max. g k Factor Number of Tubes Volume/Size Rotor Capacity 3 250 4 220 11 800 4 x 750 mL 96 x 130 mm 3.8 x 5.2 in 3L For use in Avanti J-26 XP Series. Aerosolve Canisters which are designed to provide added protection from aerosols. Rotor buckets are interchangeable with microplate carriers. No. 362734. JS-4.3 Swinging-Bucket Biosafety Rotor. Four-place rotor with anodized aluminum buckets designed for use with modular disk adapters to accommodate a variety of tubes (as indicated in the chart below) and other adapters and blood bag cups. Can be used with Beckman Coulter Bucket Covers No. 361264. Set of two. Transparent bucket covers for JS-4.3 Buckets to contain broken tubes. Includes gasket and clips. Aerosolve Canisters No. 359232. Set of four. No. 359481. Set of two. Aerosolve Canisters fit in JS-4.3 Rotor Buckets. These canisters feature an O-ring seal and are completely transparent so a broken tube can be seen and proper precautions taken before the seal is broken. Canisters can also be used as 500-mL wide-mouth bottles. Specially-designed adapters accommodate most popular tubes within the canister (see table at end of this rotor section). Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Set of 2/Set of 4 Tubes per Adapter g-Force k Factor Maximum Speed 359474/359153 359486/359164 349946 (ea.) 349846 (set of 6) 7 4 1 1 3 830 3 670 4 040 4 040 ——— ——— ——— ——— 4 300 4 300 4 300 4 300 359474/359153 359486/359164 349945 (ea.) 349846 (set of 6) 7 4 1 1 3 830 ——— 4 300 4 150 4 040 ——— ——— 4 300 4 300 Bottles with Screw-On Caps Polycarbonate 50.0 357002 25 29 x 104 250.0 750.0 355673 358299 6 6 62 x 136 96 x 130 50.0 357003 25 29 x 104 500.0 750.0 355665 356855 6 6 69 x 159 96 x 130 Conical Polycarbonate 230.0 356987 6 62 x 141 356983/349946* 356985 (ea.) 1 4 040 ——— 4 300 Conical Polypropylene 230.0 356989 6 62 x 141 356983/349946* 356985 (ea.) 1 4 040 ——— 4 300 Wide-mouth Polypropylene 250.0 356011 6 62 x 122 349946 (ea.) 1 4 040 ——— 4 300 Wide-mouth Polycarbonate 250.0 356013 6 62 x 122 349946 (ea.) 1 4 040 ——— 4 300 Polypropylene ** Use adapter 356983 with adapter 349946. ** When used with optional Aerosolve Canisters, P/N 359232 and 359481. Continued on next page. Adapters 344517 349846 349945 349946 354495 354511 Beckman Coulter High Performance Centrifuges 356983 356985 359469 359470 359471 359473 359474 359484 359486 1-47 1 www.beckmancoultercentrifugation.com JS-4.3 (continued) 1 JS-4.3 4 x 750 mL MicroPlus Carriers Replacement Parts for MicroPlus Carrier No. 362394. MicroPlus Carrier Assembly. Includes carrier, base, and rubber pad to cushion plates. Each carrier can hold up to 3 microplates, 1 deep-well/square well plate, 1 rack of MiniTubes, or other labware in 96well format. Set of 2. Maximum allowable speed is 3,250 rpm (1924 x g). 361302 361291 361304 Base and Rubber Pads (set of 2) Rubber Pads (set of 4) MicroPlus Carriers (set of 2) Tubes and Bottles (continued) Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Set of 2/Set of 4 Tubes per Adapter g-Force k Factor Maximum Speed 359474/359153 359486/359164 359474/359153 359486/359164 7 4 7 4 ——— ——— 4 300 ——— ——— ——— ——— 4 300 4 300 359474/359153 359486/359164 359474/359153 359486/359164 7 4 7 4 ——— ——— 4 300 ——— ——— ——— ——— 4 300 4 300 Bottles with Cap Assemblies Polypropylene 50.0 357001 6 29 x 104 50.0 361694 6 29 x 104 50.0 357000 6 29 x 104 50.0 361693 24 29 x 104 Wide-mouth Polypropylene 500.0 355607 6 69 x 160 349945 (ea.) 1 ——— ——— 4 300 Wide-mouth Polycarbonate 250.0 358275 25 62 x 122 349946 (ea.) 1 ——— ——— 4 300 Wide-mouth Polypropylene 250.0 358326 25 62 x 120 349946 (ea.) 1 ——— ——— 4 300 500.0 355650 6 69 x 159 349945 (ea.) 1 ——— ——— 4 300 Thickwall Polypropylene 10.0 355640 25 16 x 76 359471/359150 359484/359162 19 12 ——— ——— 4 300 Thickwall Polycarbonate 10.0 355630 25 16 x 76 ——— 4 300 342080 363664 100 25 18 x 98 29 x 104 19 12 14 7 4 ——— 15.0 50.0 359471/359150 359484/359162 359473/359152 359474/359153 359486/359164 ——— ——— ——— ——— 4 300 4 300 Polycarbonate Bottles Polypropylene Open-Top Tubes Thickwall Polyethylene 15.0 342081 100 18 x 98 359473/359152 14 ——— ——— 4 300 Thickwall Polypropylene 15.0 50.0 342082 357007 100 25 18 x 98 29 x 104 359473/359152 359474/359153 359486/359164 14 7 4 ——— ——— ——— ——— 4 300 4 300 Graduated Polycarbonate 50.0 363075 8 29 x 104 359474/359153 359486/359164 7 4 ——— ——— 4 300 1.5 357448 500 11 x 38 359469/359148 354511 (ea.)* 354495 (ea.) 26 ——— ——— 4 300 1.8 340196 500 11 x 39 359469/359148 354511 (ea.)* 354495 (ea.) 26 ——— ——— 4 300 50.0 357005 25 29 x 104 359474/359153 359486/359164 7 4 ——— ——— 4 300 Natural† 1.5 343169 500 11 x 38 26 ——— ——— 4 300 Natural† 1.5 356090 500 11 x 38 359469/359148 354511 (ea.)* 354495 (ea.) 359469/359148 354511 (ea.)* 354495 (ea.) 26 26 ——— ——— 4 300 Tubes with Snap-On Caps Polypropylene Polyethylene White Polypropylene 26 26 Adapters 344517 1-48 349846 349945 349946 354495 354511 356983 356985 359469 359470 359471 359473 359474 359484 359486 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-4.3 (continued) JS-4.3 4 x 750 mL Tubes and Bottles (continued) Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Set of 2/Set of 4 Tubes per Adapter g-Force k Factor Maximum Speed 26 ——— ——— 4 300 Tubes with Snap-On Caps (continued) Polypropylene Blue 1.5 356091 500 11 x 38 Green 1.5 356092 500 11 x 38 Yellow 1.5 356093 500 11 x 38 Orange 1.5 356094 500 11 x 38 359469/359148 354511 (ea.)* 354495 (ea.) 359469/359148 354511 (ea.)* 354495 (ea.) 359469/359148 354511 (ea.)* 354495 (ea.) 359469/359148 354511 (ea.)* 354495 (ea.) 26 26 ——— ——— 4 300 26 26 ——— ——— 4 300 26 26 ——— ——— 4 300 359470/359149 344517 (ea.) 24 10 ——— ——— 4 300 26 BioVials Polypropylene 4.0 566353 1 000 14 x 55 Aerosolve Canisters Part No. Aerosolve Canisters for JS-4.3 343686 Aerosolve Canister Adapters Color Code Typical Tube/Bottle Volume (mL) Maximum Tube Diameter (mm) Tubes per Adapter Tubes per JS-4.3 Rotor Adapter Assembly Part No. (set of 4) Adapter Assembly Part No. (set of 2) 1.5 3 and 5 5 10 12 3 and 5 15 15 and 20 3 and 5 15 3 and 5 50 3 and 5 50 3 and 5 11 12 13 14 16 12 14 18 12 17 12 30 12 29 12 24 24 24 18 12 6 10 12 6 6 6 4 4 4 4 96 96 96 72 48 24 40 48 24 24 24 16 16 16 16 354495 359482 359489 359483 359484 –––––– 359160 358993 359161 359162 344517 359485 –––––– 359163 359487 358991 359488 358992 359486 359164 Orange 230 62 1 4 ––– 356985 Canister Kit 500 ––– ––– ––– 359481 359232 White Blue Tan Orange Purple White (vials) Green Light Green (conical) Lime Green (conical) Yellow * † Rotor Replacement Parts Tube retainer (P/N 354511) is sold separately. Cap separate. 361261 361251 361264 361304 361302 362737 Aluminum Buckets, weight-matched set of 4 Rotor Yoke, forged stainless steel Bucket Cover Kit MicroPlus Multiwell Plate Carriers, with bases and pads (set of 2) Replacement Bases for MicroPlus Carriers, with pads (set of 2) Knob Assembly Adapters 344517 349846 349945 349946 354495 354511 Beckman Coulter High Performance Centrifuges 356983 356985 359469 359470 359471 359473 359474 359484 359486 1-49 1 www.beckmancoultercentrifugation.com JS-4.2 * Swinging-Bucket Rotor (Windshielded), Anodized Aluminum Axis of Rotation 1 JS-4.2 6 x 1000 mL Major applications: Rapid sedimentation of protein, rotor material, precipitates, large particles, cells, and cell debris. It can be used for binding studies and separating serum from whole blood. rmin (114 mm) rav (184 mm) rmax (254 mm) Max. RPM Max. g Capacity Rotor Approximate Accel/Decel Time (min:sec) 2 500 5 020 6 Liters, 6 Blood Bags, 18 Microplates, 336 RIA-Tubes 2:30/3:00 For use in Avanti J-HC and J6-MI centrifuges only. No. 339080. JS-4.2§ Swinging-Bucket Biosafety Rotor. Windshielded, sixplace rotor with aluminum rotor yoke and removable aluminum swinging buckets. Buckets are interchangeable with Microplate Carriers 358682‡ for spinning microtiter plates and MiniTube Racks. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Screw-On Caps Polycarbonate 10.0 50.0 250.0 500.0 750.0 1000.0 355672 357002 355673 355664 358299‡ 355675 25 25 6 6 6 6 16 x 80 29 x 104 62 x 136 69 x 160 96 x 130 97 x 167 341977 339103 339108 339109 356096 (set of 6) 356096 (set of 6) 19 7 1 1 1 1 5 020 5 020 5 020 5 020 5 020 5 020 ——— ——— ——— ——— ——— ——— 4 200 4 200 4 200 4 200 4 200 4 200 Polypropylene 50.0 500.0 750.0 1000.0 357003 355665 356855** 355676** 25 6 6 6 29 x 104 339103 69 x 159 339109 96 x 130 356096 (set of 6) 97 x 167 356096 (set of 6) 7 1 1 1 5 020 5 020 5 020 5 020 ——— ——— ——— ——— 4 200 4 200 4 200 4 200 Teflon 50.0 363076 8 28.5 x 107 339103 7 5 020 ——— 4 200 Wide-mouth Polycarbonate 250.0 500.0 356013 355605 6 6 62 x 120 69 x 160 339108 339109 1 1 5 020 5 020 ——— ——— 4 200 4 200 Wide-mouth Polypropylene 250.0 500.0 356011 355607 6 6 62 x 120 69 x 160 339108 339109 1 1 5 020 5 020 ——— ——— 4 200 4 200 Conical Polycarbonate 230.0 356987* 6 62 x 120 356983(4-pk)/339108$ 1 5 020 ——— 4 200 Conical Polypropylene 230.0 356989* 6 62 x 141 356983(4-pk)/339108 1 5 020 ——— 4 200 Polypropylene 50.0 50.0 357001 361694 6 6 29 x 104 29 x 104 339103 356997 7 1 5 020 5 020 ——— ——— 4 200 4 200 Polycarbonate 50.0 70.0 357000 355620 6 6 29 x 104 38 x 102 339103 339104 7 2 5 020 5 020 ——— ——— 4 200 4 200 Polypropylene 100.0 355624 6 38 x 102 339104 2 5 020 ——— 4 200 70.0 500.0 355655 355649 6 6 38 x 102 69 x 160 339104 339109 2 1 5 020 5 020 ——— ——— 4 200 4 200 $ Bottles with Cap Assemblies Bottles Polycarbonate Wide-mouth Polycarbonate 250.0 358275 25 62 x 122 339108 1 5 020 ——— 4 200 Polypropylene 100.0 500.0 355626 355650 6 6 38 x 102 69 x 159 339104 339109 2 1 5 020 5 020 ——— ——— 4 200 4 200 Wide-mouth Polypropylene 250.0 358326 25 62 x 120 339108 1 5 020 ——— 4 200 Tubes and Bottles (continued) * † When used with optional Aeroseal Covers, P/N 343686. Adapter used in Aerosolve Canister (P/N 359232). ** These bottles require a sleeve rather than an adapter. $ These adapters fit inside one another to accommodate smaller bottles and tubes. Adapters 339100 1-50 339101 339102 339103 339104 339108 339109 341977 354511 356096 356983 356997 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-4.2 (continued) Tube Style/Material JS-4.2 6 x 1000 mL Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Tubes with Snap-On Caps Polypropylene Natural Polycarbonate 1.5 357448 500 11 x 38 339100/354511** 26 5 020 ——— 4 200 50.0 363664 25 29 x 104 356997 1 5 020 ——— 4 200 Polyethylene Natural 1.8 340196 500 11 x 39 339100/354511** 26 5 020 ——— 4 200 Polypropylene Natural‡ Natural Blue Green Yellow Orange 1.5 1.5 1.5 1.5 1.5 1.5 50.0 343169 356090 356091 356092 356093 356094 357005 500 500 500 500 500 500 25 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 29 x 104 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339103 26 26 26 26 26 26 7 5 020 5 020 5 020 5 020 5 020 5 020 5 020 ——— ——— ——— ——— ——— ——— ——— 4 200 4 200 4 200 4 200 4 200 4 200 4 200 4.0 566353 1 000 14 x 55 339101 24 5 020 ——— 4 200 BioVials Polypropylene Open-Top Tubes Polypropylene 10.0 355640 25 16 x 76 341977 19 5 020 ——— 4 200 Polycarbonate 10.0 15.0 50.0 355630 342080 363647 25 100 25 16 x 76 18 x 98 29 x 104 341977 339102 339103 19 14 7 5 020 5 020 5 020 ——— ——— ——— 4 200 4 200 4 200 Polyethylene 15.0 342081 100 18 x 98 339102 14 5 020 ——— 4 200 Polypropylene 15.0 50.0 342082 357007 100 25 18 x 98 29 x 104 339102 339103 14 7 5 020 5 020 ——— ——— 4 200 4 200 * ‡ ** These adapters fit inside one another to accommodate smaller bottles and tubes. These tubes cannot be run with bucket covers in place. Cap separate. Blood-Bag Cups No. 339127. Yellow cup with inner diameter of 88 mm for singleand double-packs. Set of two. No. 339129. Red cup with inner diameter of 98 mm for tripleand quad-packs. Sold individually. Aeroseal Covers§ No. 343686. Cover for round buckets of JS-4.2. Features O-ring seal to provide added aerosol protection. Transparent so broken tubes can be detected and proper precautions taken before breaking seal. Quantity 1. Microplate Carriers No. 358682. Special carriers, interchangeable with buckets, slip onto yoke of JS-4.2 Rotor. Each carrier holds three microplates for a total capacity of 18 per run. Max. speed 2 500 rpm, max RCF 1 500 x g. Set of two. § Validation of microbiological containment was done at an independent, third-party facility (CAMR, Porton Down, UK or USAMRIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and, thus, containment. Rotor Replacement Parts 367045 348392 368575 339096 349817 Rotor Tie-down Kit Cover Assembly Buckets (qty: 6, blue-anodized) Bail for Adapter (curved arm at top) Bail for Adapter (straight arm at top) Adapters 339100 339101 339102 339103 339104 Beckman Coulter High Performance Centrifuges 339108 339109 341977 354511 356096 356983 356997 1-51 1 www.beckmancoultercentrifugation.com JS-4.2A ** JS-4.2A 6 x 1000 mL Swinging-Bucket Rotor (Windshielded), Anodized Aluminum Axis of Rotation Major applications: Rapid sedimentation of protein precipitates, large particles, cells, and cell debris. It can be used for binding studies and separating serum from whole blood. 1 Max. RPM Max. g Rotor Capacity Approximate Accel/Decel Time (min:sec) 2 500 5 020 6 Liters, 6 Blood Bags, 18 Microplates, 336 RIA-Tubes 2:30/3:00 rmin (114 mm) rav (184 mm) rmax (254 mm) For use in J6-MI centrifuges only. No. 366695. JS-4.2A§ Swinging-Bucket Biosafety Rotor. Windshielded, six-place rotor with aluminum rotor yoke and removable aluminum swinging buckets. Buckets are interchangeable with Microplate Carriers 358682† for spinning microtiter plates and MiniTube Racks. ARIES “Smart Balance” technology provides imbalance compensation for rotors with buckets that are unbalanced up to 100 grams. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Screw-On Caps Polycarbonate 10.0 50.0 750.0 1000.0 355672 357002 358299* 355675*£ 25 25 6 6 16 x 80 341977 29 x 104 339103 96 x 130 356096 (set of 6) 97 x 167 356096 (set of 6) 19 7 1 1 5 020 5 020 5 020 5 020 ——— ——— ——— ——— 4 200 4 200 4 200 4 200 Polycarbonate 250.0 500.0 355673 355664 6 6 62 x 136 69 x 160 1 1 5 020 5 020 ——— ——— 4 200 4 200 Polypropylene 500.0 750.0 1000.0 355665 356855* 355676* £ 6 6 6 69 x 159 339109 96 x 130 356096 (set of 6) 97 x 167 356096 (set of 6) 1 1 1 5 020 5 020 5 020 ——— ——— ——— 4 200 4 200 4 200 339108 339109 Wide-mouth Polycarbonate 250.0 250.0 500.0 358275 356013 355605 25 6 6 62 x 122 62 x 120 69 x 160 339108 339108 339109 1 1 1 5 020 5 020 5 020 ——— ——— ——— 4 200 4 200 4 200 Wide-mouth Polypropylene 250.0 250.0 500.0 358326 356011 355607 25 6 6 62 x 122 62 x 120 69 x 160 339108 339108 339109 1 1 1 5 020 5 020 5 020 ——— ——— ——— 4 200 4 200 4 200 Conical Polycarbonate 230.0 356987 6 60 x 120 356983/339108+ 1 5 020 ——— 4 200 Conical Polypropylene 230.0 356989 6 60 x 120 356983/339108+ 1 5 020 ——— 4 200 Polycarbonate 70.0 500.0 355655 355649 6 6 38 x 102 69 x 160 339104 339109 2 1 5 020 5 020 ——— ——— 4 200 4 200 Polypropylene 50.0 100.0 500.0 357003 355626 355650 25 6 6 29 x 104 38 x 102 69 x 159 339103 339104 339109 7 2 4 5 020 5 020 5 020 ——— ——— ——— 4 200 4 200 4 200 Polypropylene 50.0 50.0 357001 361694 6 6 29 x 104 29 x 104 339103 356997 7 1 5 020 5 020 ——— ——— 4 200 4 200 Polycarbonate 50.0 70.0 357000 355620 6 6 29 x 104 38 x 102 339103 339104 7 2 5 020 5 020 ——— ——— 4 200 4 200 Polypropylene 100.0 355624 6 38 x 102 339104 2 5 020 ——— 4 200 Bottles Bottles with Cap Assemblies Microplate carriers cannot be run in the Avanti J-HC centrifuge. ** These bottles require a sleeve rather than an adapter. ** When used with optional Aeroseal Covers, P/N 343686 ‡ + £ These adapters fit inside one another to accommodate smaller bottles and tubes. can’t be used with the Aeroseal covers Adapters 339103 1-52 339104 339108 339109 341977 356096 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-4.2A (continued) JS-4.2A 6 x 1000 mL Tubes and Bottles (continued) Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor 339100/354511** 26 5 020 ——— Maximum Speed Tubes with Snap-On Caps Polypropylene Natural 1.5 Polycarbonate 357448 500 11 x 38 4 200 50.0 363664 25 29 x 104 356997 1 Polyethylene Natural 1.5 340196 500 11 x 39 339100/354511** 26 5 020 ——— 4 200 4 200 Polypropylene Natural Natural Blue Green Yellow Orange 1.5 1.5 1.5 1.5 1.5 1.5 50.0 356090 343169 356091 356092 356093 356094 357005 500 500 500 500 500 500 25 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 29 x 104 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339103 26 26 26 26 26 26 7 5 020 5 020 5 020 5 020 5 020 5 020 5 020 ——— ——— ——— ——— ——— ——— ——— 4 200 4 200 4 200 4 200 4 200 4 200 4 200 4.0 566353 1 000 14 x 55 339101 24 5 020 ——— 4 200 BioVials Polypropylene Open-Top Tubes Polypropylene 10.0 355640 25 16 x 76 341977 19 5 020 ——— 4 200 Polycarbonate 10.0 15.0 50.0 355630 342080 363647 25 100 25 16 x 76 18 x 98 29 x 104 341977 339102 356997 19 14 7 5 020 5 020 5 020 ——— ——— ——— 4 200 4 200 4 200 Polyethylene 15.0 342081 100 18 x 98 339102 14 5 020 ——— 4 200 Polypropylene 15.0 50.0 342082 357007 100 25 18 x 98 29 x 104 339102 339103 14 7 5 020 5 020 ——— ——— 4 200 4 200 ** hese adapters fit inside one another to accommodate smaller bottles and tubes. Blood-Bag Cups No. 339127. Yellow cup with inner diameter of 88 mm for singleand double-packs. Sold individually. No. 339129. Red cup with inner diameter of 98 mm for tripleand quad-packs. Sold individually. Aeroseal Covers§ No. 343686. Cover for round buckets of JS-4.2A. Features O-ring seal to provide added aerosol protection. Transparent so broken tubes can be detected and proper precautions taken before breaking seal. Quantity 1. Microplate Carriers No. 358682. Special carriers, interchangeable with buckets, slip onto yoke of JS-4.2A Rotor. Each carrier holds three microplates for a total capacity of 18 per run. Max. speed 2 500 rpm. Set of two. § Validation of microbiological containment was done at an independent, third-party facility (CAMR, Porton Down, UK or USAMRIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and, thus, containment. Rotor Replacement Parts 367045 348392 368575 339096 349817 Rotor Tie-down Kit Cover Assembly Buckets (qty: 6, blue-anodized) Bail for Adapter (curved arm at top) Bail for Adapter (straight arm at top) Adapters 339100 339101 339102 339103 Beckman Coulter High Performance Centrifuges 339108 339109 354511 356983 356997 1-53 1 www.beckmancoultercentrifugation.com JS-4.2SM JS-4.2SM 6 x Quad Blood Bag Packs Swinging-Bucket Rotor (Windshielded), Anodized Aluminum Axis of Rotation 1 rmin (116 mm) rav (182 mm) rmax (248 mm) Major applications: Separation of serum or plasma from whole blood, blood component separation. Max. RPM Max. g Rotor Capacity Approximate Accel/Decel Time (min:sec) 2 500 4 900 6 Blood Bags 18 Microplates 2:30/3:00 For use in J6-MI centrifuge only. No. 348394. JS-4.2SM Swinging-Bucket Rotor. Windshielded, six-place rotor designed with oval-shaped buckets specifically for blood bank applications which utilize similarly shaped blood bags. Buckets are interchangeable with microplate carriers for blood serum studies. Includes six oval-shaped blood-bag cups. Microplate Carriers No. 358682. Special carriers, interchangeable with buckets, slip onto yoke of JS-4.2SM Rotor. Each carrier holds three microplates for a total capacity of 18 per run. Maximum speed 2 500 rpm. Set of two. Blood-Bag Cups No. 363651. Oval-shaped gray cup for quad-packs (filters). Set of two. Rotor Replacement Parts 367045 348392 348393 348359 1-54 Rotor Tie-down Kit Cover Assembly Buckets (set of 6) Liners Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-4.2SMA JS-4.2SMA 6 x Quad Blood Bag Packs Swinging-Bucket Rotor (Windshielded), Anodized Aluminum Axis of Rotation rmin (116 mm) rav (182 mm) rmax (248 mm) Major applications: Separation of serum or plasma from whole blood, blood component separation. Max. RPM Max. g Rotor Capacity Approximate Accel/Decel Time (min:sec) 2 500 4 900 6 Blood Bags 2:30/3:00 For use in J6-MI centrifuge only. No. 366670. JS-4.2SMA Swinging-Bucket Rotor. Windshielded, sixplace rotor designed with oval-shaped buckets specifically for blood bank applications which utilize similarly shaped blood bags. Buckets are interchangeable with microplate carriers for blood serum studies. Includes six oval-shaped blood-bag cups. ARIES “Smart Balance” technology provides imbalance compensation for rotors with buckets that are unbalanced up to 100 grams. Microplate Carriers No. 358682. Special carriers, interchangeable with buckets, slip onto yoke of JS-4.2SMA Rotor. Each carrier holds three microplates for a total capacity of 18 per run. Maximum speed 2 500 rpm. Set of two. Blood-Bag Cups No. 363651. Oval-shaped gray cup for quad-packs (filters). Set of two. Rotor Replacement Parts 367045 348392 348393 348359 Beckman Coulter High Performance Centrifuges Rotor Tie-down Kit Cover Assembly Buckets (set of 6) Liners 1-55 1 www.beckmancoultercentrifugation.com JS-4.0 * JS-4.0 4 x 1000 mL Swinging-Bucket Rotor (Unshielded), Aluminum Major applications: Rapid sedimentation of protein precipitates, large particles, cells, and cell debris. It can be used for binding studies and separating serum or plasma from whole blood. Axis of Rotation 1 rmin (86 mm) rav (156 mm) rmax (226 mm) Max. RPM Max. g Rotor Capacity Approximate Accel/Decel Time 4 000 4 050 4 Liters, 4 Blood Bags, 12 Microplates, 148 RIA Tubes 2:00/1:30 min. For use in Avanti J-26S and J6-MI centrifuges. No. 339086. JS-4.0 Swinging-Bucket Biosafety Rotor. Unshielded, four-place rotor with aluminum rotor yoke and removable aluminum swinging buckets. Buckets are interchangeable with Microplate Carriers for spinning microtiter plates and MiniTube Racks. Note: requires tie-down kit P/N 367045 for use with Avanti J-26S Series centrifuges. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Screw-On Caps Polycarbonate 10.0 50.0 250.0 500.0 750.0 1000.0 355672 357002 355673 355664 358299 355675 25 25 6 6 6 6 16 x 80 29 x 104 62 x 136 69 x 160 96 x 130 97 x 167 341977 339103 339108 339109 356096 (set of 6) 356096 (set of 6) 19 N/A 1 1 1 1 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— 4 000 4 000 4 000 4 000 4 000 4 000 Polypropylene 50.0 500.0 750.0 1000.0 357003 355665 356855 355676 25 6 6 6 29 x 104 69 x 159 96 x 139 97 x 167 339103 339109 356096 (set of 6) 356096 (set of 6) 7 1 1 1 ——— ——— ——— ——— ——— ——— ——— ——— 4 000 4 000 4 000 4 000 Wide-mouth Polycarbonate 250.0 500.0 356013 355605 6 6 62 x 120 69 x 160 339108 339109 1 1 ——— ——— ——— ——— 4 000 4 000 Wide-mouth Polypropylene 250.0 500.0 356011 355607 6 6 62 x 120 69 x 160 339108 339109 1 1 ——— ——— ——— ——— 4 000 4 000 Conical Polycarbonate 230.0 356987 6 60 x 120 356983/339108** 1 ——— ——— 4 000 Conical Polypropylene 230.0 356989 6 60 x 120 356983/339108** 1 ——— ——— 4 000 Polypropylene 50.0 50.0 357001 361694 6 6 29 x 104 29 x 104 339103 356997 N/A 1 ——— ——— ——— ——— 4 000 4 000 Polycarbonate 50.0 70.0 357000 355620 6 6 29 x 104 38 x 102 339103 339104 N/A 2 ——— ——— ——— ——— 4 000 4 000 Polypropylene 100.0 355624 6 38 x 102 339104 2 ——— ——— 4 000 70.0 500.0 355655 355649 6 6 38 x 102 69 x 160 339104 339109 2 1 ——— ——— ——— ——— 4 000 4 000 Bottles with Cap Assemblies Bottles Polycarbonate Wide-mouth Polycarbonate 250.0 358275 25 62 x 122 339108 1 ——— ——— 4 000 Polypropylene 100.0 500.0 355626 355650 6 6 38 x 102 69 x 159 339104 339109 2 1 ——— ——— ——— ——— 4 000 4 000 Wide-mouth Polypropylene 250.0 358326 25 62 x 122 339108 1 ——— ——— 4 000 * When used with optional Aeroseal Covers P/N 343686. ** These adapters fit inside one another to accommodate smaller bottles and tubes. Adapters 339100 1-56 339101 339102 339103 339104 339108 339109 341977 354511 356096 356983 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-4.0 (continued) JS-4.0 4 x 1000 mL 1 Tubes and Bottles (continued) Tube Style/Material Nominal Volume per Tube (mL) Part No. Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Tubes with Snap-On Caps Polypropylene Natural Polycarbonate Polyethylene 1.5 357448 500 11 x 38 339100/354511** 26 ——— ——— 4 000 50.0 363664 25 29 x 104 365997 7 ——— ——— 4 000 1.8 340196 500 11 x 39 339100/354511** 26 ——— ——— 4 000 1.5 1.5 1.5 1.5 1.5 1.5 50.0 356094 356093 356092 356091 356090 343169 357005 500 500 500 500 500 500 25 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 29 x 104 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339103 26 26 26 26 26 26 7 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— 4 000 4 000 4 000 4 000 4 000 4 000 4 000 Polypropylene 10.0 355640 25 16 x 76 341977 19 ——— ——— 4 000 Polycarbonate 10.0 15.0 50.0 355630 342080 363647 25 100 25 16 x 76 18 x 98 29 x 104 341977 339102 339103 19 14 7 ——— ——— ——— ——— ——— ——— 4 000 4 000 4 000 Polypropylene Orange Yellow Green Blue Clear Natural* Open-Top Tubes Polyethylene 15.0 342081 100 18 x 100 339102 14 ——— ——— 4 000 Polypropylene 15.0 50.0 342082 357007 100 25 18 x 98 29 x 104 339102 356997 14 7 ——— ——— ——— ——— 4 000 4 000 4.0 566353 1000 14 x 55 339101 24 ——— ——— 4 000 19 ——— ——— ——— 37 24 19 5 14 4 4 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— BioVials Polypropylene Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom 3.0 & 5.0 ——— ——— Round Bottom Round Bottom Round Bottom Conical Round Bottom Conical Round Bottom 3.0 & 5.0 10.0 12.0 15.0 20.0 50.0 50.0 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— 12 x 75 339119 (double stacked) adapter) (qty. of 1) 12 x 133 339100 (qty. of 1) 14 x 133 339101 (qty. of 1) 16 x 133 341977 (qty. of 1) 17 x 119 356995 (qty. of 1) 18 x 133 339102 (qty. of 1) 30 x 136 345386 (qty. of 1) 35 x 136 341794 (qty. of 1) * Cap separate. ** These adapters fit inside one another to accommodate smaller bottles and tubes. Adapters 339100 339101 339102 339103 339104 Beckman Coulter High Performance Centrifuges 339108 339109 341977 354511 356096 356983 1-57 www.beckmancoultercentrifugation.com JS-4.0 (continued) JS-4.0 4 x 1000 mL 1 Blood-Bag Cups No. 339127. Yellow cup with inner diameter of 88 mm for single- and double-packs. Sold individually. No. 339129. Red cup with inner diameter of 98 mm for triple- and quad-packs. Sold individually. Aeroseal Covers No. 343686. Cover for round buckets of JS-4.0. Features O-ring seal to provide added aerosol protection. Transparent so broken tubes can be detected and proper precautions taken before breaking seal. Quantity 1. Microplate Carriers No. 358680. Special carriers, interchangeable with buckets, slip onto yoke of JS-4.0 Rotor. Each carrier holds three microplates for a total capacity of 12 per run. Maximum speed 2 600 rpm (1450 x g). Set of two. Rotor Replacement Parts 339031 341710 878439 367045 1-58 Rotor Tie-down Screw Bucket Set (set of 4) Torquing Bar for Rotor Tie-down Screw Rotor Tie-down Kit for Avanti J-26S XP Series centrifuges Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-3.0 ** JS-3.0 6 x 1000 mL Swinging-Bucket Rotor (Unshielded), Anodized Aluminum Major applications: Rapid sedimentation of protein precipitates, large particles, cells, and cell debris. It can be used for binding studies and separating serum from whole blood. Axis of Rotation rmin (114 mm) rav (184 mm) rmax (254 mm) Max. RPM Max. g Rotor Capacity Approximate Accel/Decel Time (min:sec) 3 000 2 560 6 Liters, 6 Blood Bags, 18 Microplates, 336 RIA-Tubes 2:00/1:30 min. For use in J6-MI centrifuge only. No. 339081. JS-3.0§ Swinging-Bucket Biosafety Rotor. Unshielded, sixplace rotor with aluminum rotor yoke and removable aluminum swinging buckets. Buckets are interchangeable with Microplate Carriers 358682 for spinning microtiter plates and MiniTube Racks in the JS-3.0 Rotor. Tubes and Bottles Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Bottles with Screw-On Caps Polycarbonate 10.0 50.0 250.0 500.0 750.0 1000.0 355672 357002 355673 355664 358299 355675 25 25 6 6 6 6 16 x 80 341977 29 x 104 339103 62 x 136 339108 69 x 160 339109 96 x 130 356096* (set of 6) 97 x 167 356096* (set of 6) 19 7 1 1 1 1 2 560 2 560 2 560 2 560 2 560 2 560 ——— ——— ——— ——— ——— ——— 3 000 3 000 3 000 3 000 3 000 3 000 Polypropylene 50.0 500.0 750.0 1000.0 357003 355665 356855 355676 25 6 6 6 29 x 104 339103 69 x 159 339109 96 x 130 356096* (set of 6) 97 x 167 356096* (set of 6) 7 1 1 1 2 560 2 560 2 560 2 560 ——— ——— ——— ——— 3 000 3 000 3 000 3 000 Wide-mouth Polycarbonate 250.0 500.0 356013 355605 6 6 62 x 122 69 x 160 339108 339109 1 1 2 560 2 560 ——— ——— 3 000 3 000 Wide-mouth Polypropylene 250.0 500.0 356011 355607 6 6 62 x 120 69 x 160 339108 339109 1 1 2 560 2 560 ——— ——— 3 000 3 000 Conical Polycarbonate 230.0 356987 6 60 x 120 356983/339108+ 1 2 560 ——— 3 000 Conical Polypropylene 230.0 356989 6 60 x 120 356983/339108+ 1 2 560 ——— 3 000 Polypropylene 50.0 50.0 357001 361694 6 6 29 x 104 29 x 104 339103 356997 7 1 2 560 5 020 ——— ——— 3 000 4 200 Polycarbonate 50.0 70.0 357000 355620 6 6 29 x 104 38 x 102 339103 339104 7 2 2 560 2 560 ——— ——— 3 000 3 000 Polypropylene 100.0 355624 6 38 x 102 339104 2 2 560 ——— 3 000 70.0 500.0 355655 355649 6 6 38 x 102 69 x 160 339104 339109 2 1 2 560 2 560 ——— ——— 3 000 3 000 Bottles with Cap Assemblies Bottles Polycarbonate Wide-mouth Polycarbonate 250.0 358275 25 62 x 122 339108 1 2 560 ——— 3 000 Polypropylene 100.0 500.0 355626 355650 6 6 38 x 102 69 x 159 339104 339109 2 1 2 560 2 560 ——— ——— 3 000 3 000 Wide-mouth Polypropylene 250.0 358326 25 62 x 122 339108 1 2 560 ——— 3 000 354511 356096 + These adapters fit inside one another to accommodate smaller bottles and tubes. Adapters 339100 339101 339102 339103 339104 Beckman Coulter High Performance Centrifuges 339108 339109 341977 356983 356997 1-59 1 www.beckmancoultercentrifugation.com JS-3.0 (continued) JS-3.0 6 x 1000 mL 1 Tubes and Bottles (continued) Tube Style/Material Nominal Part No. Volume per Tube (mL) Quantity Cavity Diameter (mm) Required Adapters Tubes per Adapter g-Force k Factor Maximum Speed Tubes with Snap-On Caps Polypropylene Natural Polycarbonate 1.5 357448 500 11 x 38 339100/354511** 26 2 560 ——— 3 000 50.0 363664 25 29 x 104 356997 1 2 560 ——— 3 000 Polyethylene Natural 1.8 340196 500 11 x 39 339100/354511** 26 2 560 ——— 3 000 Polypropylene Natural* Clear Blue Green Yellow Orange 1.5 1.5 1.5 1.5 1.5 1.5 50.0 343169 356090 356091 356092 356093 356094 357005 500 500 500 500 500 500 25 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 11 x 38 29 x 104 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339100/354511** 339103 26 26 26 26 26 26 7 2 560 2 560 2 560 2 560 2 560 2 560 2 560 ——— ——— ——— ——— ——— ——— ——— 3 000 3 000 3 000 3 000 3 000 3 000 3 000 4.0 566353 1 000 14 x 55 339101 24 2 560 ——— 3 000 BioVials Polypropylene Open-Top Tubes Polypropylene 10.0 355640 25 16 x 76 341977 19 2 560 ——— 3 000 Polycarbonate 10.0 15.0 50.0 355630 342080 363647 25 100 25 16 x 76 18 x 98 29 x 104 341977 339102 356997 19 14 7 2 560 2 560 2 560 ——— ——— ——— 3 000 3 000 3 000 Polyethylene 15.0 342081 100 18 x 98 339102 14 2 560 ——— 3 000 Polypropylene 15.0 50.0 342082 357007 100 25 18 x 98 29 x 104 339102 339103 14 7 2 560 2 560 ——— ——— 3 000 3 000 19 ——— ——— ——— 37 24 19 5 14 4 4 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— Adapters for Non-Beckman Coulter Tubes/Bottles Round Bottom 3.0 & 5.0 ——— ——— Round Bottom Round Bottom Round Bottom Conical Round Bottom Conical Round Bottom 3.0 & 5.0 10.0 12.0 15.0 20.0 50.0 50.0 ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— ——— 12 x 75 339119 (double stacked) adapter) (qty. of 1) 12 x 133 339100 (qty. of 1) 14 x 133 339101 (qty. of 1) 16 x 133 341977 (qty. of 1) 17 x 119 356995 (qty. of 1) 18 x 133 339102 (qty. of 1) 30 x 136 345386 (qty. of 1) 35 x 136 341794 (qty. of 1) ** These adapters fit inside one another to accommodate smaller bottles and tubes. Adapters 339100 1-60 339101 339102 339103 339104 339108 339109 341977 354511 356096 356983 356997 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JS-3.0 (continued) JS-3.0 6 x 1000 mL 1 Blood-Bag Cups No. 339127. Yellow cup with inner diameter of 88 mm for single- and double-packs. Sold individually. No. 339129. Red cup with inner diameter of 98 mm for triple- and quad-packs. Sold individually. Aeroseal Covers No. 343686. Cover for round buckets of JS-3.0. Features O-ring seal to provide added aerosol protection. Transparent so broken tubes can be detected and proper precautions taken before breaking seal. Quantity 1. Microplate Carriers No. 358682. Special carriers, interchangeable with buckets, slip onto yoke of JS-3.0 Rotor. Each carrier holds three microplates for a total capacity of 18 per run. Max. speed 2 500 rpm, max RCF 1 500 x g. Set of two. Rotor Replacement Parts 367045 368575 Beckman Coulter High Performance Centrifuges Rotor Tie-down Kit Buckets (set of 6, blue-anodized) 1-61 www.beckmancoultercentrifugation.com JCF-Z JCF-Z How To Order the JCF-Z Rotor 1 For a complete Beckman Coulter JCF-Z Rotor system, the following components are required. 1. A JCF-Z Rotor (choose according to application; continuous flow, zonal, or reorienting gradient). 2. Optional high-flow seal assembly for processing up to 100 liters/hour. 3. An appropriate bracket assembly (for Avanti J Series instruments only). 4. A pump system (not supplied by Beckman Coulter, but recommendations below). 5. A Beckman Coulter Avanti J Series centrifuge (excluding J-E). Continuous-Flow Rotors No. 335140. JCF-Z Continuous-Flow Rotor, Titanium, Standard Pellet Core. Includes Standard continuous-flow core (pellet size 400 mL), standardflow rotating seal assembly, and tool kit. Bracket kit required for use with Avanti J Series centrifuges, and pump system required for all applications. Max. RPM Max. g k Factor Rotor Capacity 20 000 39 900 100 660 mL No. 357544. JCF-Z Continuous-Flow Rotor, Titanium, Small Pellet Core. Includes Small Pellet continuous-flow core (pellet size 200 mL), standard-flow rotating seal assembly, and tool kit. Bracket kit required for use with Avanti J Series centrifuges, and pump system required for all applications. Max. RPM Max. g k Factor Rotor Capacity 20 000 36 300 281 240 mL No. 357521. JCF-Z Continuous-Flow Rotor, Titanium, Large Pellet Core. Includes Large Pellet continuous-flow core (pellet size 800 mL), standard-flow rotating seal assembly, and tool kit. Bracket kit required for use with Avanti J Series centrifuges, and pump system required for all applications. Max. RPM Max. g k Factor Rotor Capacity 20 000 39 900 293 1 250 mL Bracket Kits for use with Avanti J-Series centrifuges Zonal and Reorienting Gradient Rotors No. 354006. JCF-Z Zonal Rotor, Titanium. Includes Zonal core, standard-flow rotating seal assembly, and tool kit. Bracket kit required for use with Avanti J Series centrifuges, and pump system required for all applications. Max. RPM Max. g k Factor Rotor Capacity 20 000 39 900 710 1 900 mL No. 354005. JCF-Z Reorienting Gradient Rotor, Titanium. Includes reorienting gradient core, sample transfer assembly, and tool kit. Bracket kit required for use with Avanti J Series centrifuges, and pump system required for all applications. Max. RPM Max. g k Factor Rotor Capacity 20 000 39 900 779 1 750 mL Interchangeable Cores and Accessories 335130 350641 350601 335141 343348 350585 335142 335134 Continuous-flow Core, Standard Continuous-flow Core, Large-Pellet Continuous-flow Core, Small-Pellet Zonal Core Zonal Keylock Switch for J2-21 Reorienting Gradient Core and Sample Transfer Assembly Standard-flow, Rotating Seal Assembly required for Zonaland Continuous-flow Operation High-flow Seal Assembly Kit: permits processing up to 100 liters/hour in Continuous-flow Core JCF-Z-Rotor Replacement Parts 335144 812715 815473 824412 854519 366190 870655 870688 335143 Rotating Seal, Carbon-graphite O-ring for JCF-Z Rotor Plug (Min. order 12) O-ring for JCF-Z Rotor Lid Stem, 5⁄8” O.D. (Min. order 6) O-ring for JCF-Z Rotating Seal, 3⁄4” O.D. (Min. order 6) O-ring for bottom of JCF-Z-Rotor Bowl (Min. order 6) Bearing, Stainless Steel O-ring for JCF-Z Rotating Seal, .502 O.D. (Min. order 6) O-ring for JCF-Z Rotor Lid, 7.188 O.D. Tool Kit No. 363843. Bracket Kit, for use with Avanti J-25 Series and Avanti J-30I centrifuges, and standard Cole-Parmer size-16 tubing (6.4 mm, 1/4-in. O.D.). For other size tubing, see optional kits below. No. 366431. Bracket Kit, for use with Avanti J-26 XP Series centrifuges, and standard Cole-Parmer size-16 tubing (6.4 mm, 1/4-in. O.D.). For other size tubing, see optional kits below. No. 363844. Size-14 Tubing Adapter Kit, for use with Cole-Parmer size-14 tubing (4.8 mm, 3/16 in.). Order in addition to one of above Bracket Kits. No. 363845. Size-15 Tubing Adapter Kit, for use with Cole-Parmer size-15 tubing (9.5 mm, 3/8 in.). Order in addition to one of above Bracket Kits. Recommended Pumps The chosen pump must meet the following requirements: (a) has a continuously adjustable flow rate from 6 to 100 mL/min; (b) has a flow rate controllable to within ±1.5%; (c) has a flow rate independent of back pressure up to 40 psi; and (d) has pulsation less than 5% of flow rate. We recommend Cole-Parmer Masterflex L/S Standard Digital Pump E-77921-00 (115 VAC), or L/S Standard Digital Pump E-77921-07 (230 VAC). These are not available from Beckman Coulter, but may be ordered direct from Cole-Parmer (625 East Bunker Court, Vernon Hills, Illinois 60061-1844 USA, Phone 847-549-7600, Fax 847-549-7676, TDD hotline: 800-8337400, E-mail: [email protected]). Contact Cole-Parmer directly to receive current ordering information for these or comparable pumps. These pumps include: Easy-Load* pump head model E-07518-12 (accepts L/S 15 and L/S 24 tubing), 10 ft. (3 m) of Tygon† LFL L/S 24 tubing model E-06429-24 (flow range of 28 to 1700 ml/min), and 10 to 600 rpm standard digital drive model E-07523-20 (115 VAC) or E-07523-27 (230 VAC). 1-62 Small Pellet Core Reorienting Gradient Core Large Pellet Core Zonal Core Standard Continuous Flow Core For use in Avanti J Series centrifuges (except Avanti J-E). Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JCF-Z (continued) JCF-Z Many of the parts on this list are pictured for easy identification. Supply List 336079 366190 336285 350585 335136 335146 344108 338672 336080 336284 870526 817033 824412 824464 870656 870315 870689 335120 335132 336286 804063 870690 335133 335148 339555 306812 870654 335145 336403 306653 878279 853118 853391 870658 * Bearing Housing (anodized aluminum) Bearing (stainless steel) Bearing Spacer (stainless steel) Reorienting Gradient Core and Sample Transfer Assembly Feed Fitting, High-flow (stainless steel)* Feed Fitting, Standard-flow (stainless steel)* Fitting Retaining Clamp (modified polyphenylene oxide) Housing, High-flow Stationary Seal (stainless steel) Housing, Standard-flow Stationary Seal (stainless steel) Mount, Rotating Seal (stainless steel) O-ring, Continuous-flow Lid O-ring, (Viton13), Continuous-flow Lid O-ring, Rotating Seal O-ring, Seal Housing Feed Fitting O-ring, (Viton13), Transfer Tube Assembly O-ring, Zonal Lid Retaining Ring (stainless steel) Sample Transfer Tube, Standard-flow Seal Assembly (stainless steel) Sample Transfer Tube, High-flow Seal Assembly (stainless steel) Scavenger Drain Tube (stainless steel) Screw (stainless steel) Screw (stainless steel) Seal Assembly, High-flow Silicone Vacuum Grease Solution 555 Rotor Cleaning Concentrate Spinkote Lubricant Spring (stainless steel) Stationary Seal (ceramic) Stoppers for Tubing Lines (#1, one-hole) Tygon Tubing Washer, Flat (nylon) Washer, High-flow Seal Washer, Flat (stainless steel) Washer, Spring (spring steel) 1 344108 870690 853118 Manifold 336080 824464 336286 335146 Standard-flow (SF) Seal Housing High-flow (HF) Seal Housing Assembly 335133 870655 868638 344108 335145 870689 335144 824412 335146 824464 870656 Housing 335120 (SF) or 335132 (HF); and 306653 870656 870689 870689 870656 Use Loctite grade “T” primer and #35 retaining compound to bond fitting to seal housing. 853391 870654 853391 336284 870656 336079 Transfer Assembly (reograd only) 878279 804063 344269 870658 Seal and Transfer Assemblies 336285 344269 Seal Assembly (all other cores) Beckman Coulter High Performance Centrifuges Note: Standard-flow Manifold consists of part numbers 870690, 853118, 336080, 870655, 868638, and 335145. High-flow Manifold is part of High-flow Seal Housing Assembly, which consists of part numbers 870690, 853118, 338672, 2 x 335136, and 336286. 1-63 www.beckmancoultercentrifugation.com JE-5.0 JE-5.0 Elutriation Elutriator Rotor For use in Avanti J-26 XP Series and J6-MI centrifuges equipped with viewport door and strobe assembly. Axis of Rotation 1 reb and rmin rmax Max. RPM Max. g Maximum Volume Elutriation Boundary 5 000 4 700 40 mL 86 mm (2,410 g) For use in Avanti J-26S centrifuge.* Centrifugal Force reb= Elutriation Boundary No. 356900. JE-5.0 Elutriator Rotor Assembly. Includes bypass chamber and supplies, and features a quick-release assembly which can be autoclaved for sterile operation. Order elutriation chamber(s) separately. (For complete Elutriation System, a number of components are necessary. See How to Order below.) Elutriation Chamber Description Part No. Max. Cells Recovered per Run Minimum Cells Required for Loading per Fraction Max Elutriated Buffer Volume 40-mL 5-mL Sanderson 356940 356943 356945 1010 1010 1010 107 107 105 1000 mL 1000 mL 1000 mL How to Order For a complete Beckman Coulter Elutriation System, the following components are required: 1. An Elutriator Rotor Assembly 2. An Elutriation Chamber 3. An Elutriation Centrifuge equipped with viewport door and strobe assembly. Beckman Coulter Avanti J-26S centrifuges can be ordered as Elutriation Centrifuges fully equipped with the appropriate door and strobe assembly. See Section 1 for ordering information. Also necessary but not available from Beckman Coulter is a pump that meets the following requirements: (a) has continuously adjustable flow rate from 6 to 100 mL/min; (b) has flow rate controllable to within ± 1.5%; (c) has flow rate independent of back pressure up to 40 psi; and (d) has pulsation less than 5% of flow rate. Recommended pumps are listed below. Recommended Pump (not supplied by Beckman Coulter) We recommend the Cole-Parmer Masterflex Digital Drive Pump System. These are not available from Beckman Coulter, but may be ordered directly from Cole-Parmer (625 East Bunker Court, Vernon Hills, Illinois 60061-1844 USA, Phone 847-549-7600, Fax 847-5497676, TDD hotline: 800-833-7400, E-mail: [email protected]). Contact Cole-Parmer directly to receive current ordering information for these or comparable pumps. A complete pump consists of one each of the following components: 1. Easy-Load pump head (stainless steel) 2. Tygon L/S 16 tubing standard drive (10 to 600 rpm, 115 VAC or 230 VAC) Supplies 335148 339555 306812 357520 357580 Silicone Vacuum Grease, 1 oz Solution 555 Cleaning Concentrate, 1 qt Spinkote Lubricant (for rotor/shaft interface), 2 oz Tubing, Tygon 1/8-in. (I.D.) × 1/4-in. (O.D.) Tubing, Silicone 3/16-in. (I.D.) × 5/16-in. (O.D.) (for rotating seal-assembly connection) Tools 927784 016223 927766 029840 001884 817305 Pliers for Retaining Clip (bearing removal) Wrench, 1/8-in. Hex Driver Wrench, 5/16-in. Hex T-handle Wrench, 5/32-in. Hex Driver Wrench, 5/64-in. Hex Driver Wrench, 9/64-in. Hex Angle To Upgrade an Existing Beckman Coulter Centrifuge For Avanti J-26 XP Series, order the appropriate kit listed below (order only one kit): No. 366562. 50/60 Hz. For use with Avanti J-26 XP. Kit includes Strobe Lamp/Control Assembly and Door Assembly with Viewport. No. 366563. 50/60 Hz. For use with Avanti J-26 XPI. Kit includes Strobe Lamp/Control Assembly and Door Assembly with Viewport. * When properly equipped for elutriation. 1-64 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com JE-5.0 (continued) Replacement Parts 358291 366922 358182 355161 356014 356940 356941 356943 356944 356945 356946 849660 356917 356907 356935 359399 356930 356921 356942 927768 000148 870671 356912 356911 870655 011519 868638 853984 853696 010426 356910 340148 347549 878681 356915 927286 335213 335197 803993 927569 841717 824905 929279 347526 335145 347543 356913 357459 340145 356920 356919 356914 870669 021623 887438 889303 927730 927731 852685 878475 347978 JE-5.0 Elutriation 927569 356915 Quick-release Seal Assembly 5.0 with counterbalance Anchor Cable Assembly for Avanti J-26 XP Series centrifuge 853696 853984 Anchor Cable Assembly for J6-MI centrifuge 356914 Ball Bearing, S.C.D. 853984 Cable Retainer Chamber, Large (40-mL), “A” 356912 Chamber, Large (40-mL), “B” Chamber, Standard (5-mL), “A” Chamber, Standard (5-mL), “B” 340145 Chamber, Sanderson (5-mL), “A” 357459 Chamber, Sanderson (5-mL), “B” 347526 Chamber Mounting Nut Chamber Pad 363328 803993 Chamber Gasket, 40-mL 927731 Chamber Gasket, 4-mL Chamber Gasket, Sanderson, 4-mL Chamber Mount Chamber Tube (solid) 356910 Counterbalance Fitting, Inlet Line (to seal assembly), 3/16 in. I.D. 010426 (O-ring) Fuse, Strobe, 1.0 A-TD 250 VAC Chamber (Solid) 356921 Glass Plate for Lapping Seal (4 x 5 in.) Gasket 356919 Housing, Bearing 40-mL, 356907 356920 335145 Housing, Seal 4-mL, 356935 868638 O-ring, Small, Seal Housing Sanderson, 359399 870655 O-ring, Small, Bearing Shaft O-ring, Large, Seal Housing O-ring, Center Tube 964910 O-ring, Retaining, Center Tube O-ring, Transfer Tube 964942 889303 Plate, Chamber/Seal Support 824905 Pressure Gauge Assembly 929279 Reflector, rpm Retaining Clip, Bearing Assembly 356917 Retaining Plate, Transfer Tube Retaining Ring, Internal Sample Reservoir, 30-mL Sample Reservoir, 75-mL Screw, Cap (support plate to seal housing) Screw, Cap (retaining plate) Screw, Chamber Mounting Screw, Housing Screw, Shoulder (chamber assembly) Seal, Rotating, Black Seal, Stationary, White Syringe Assembly Shaft (bearing) Spacer (spring/seal) Spring (seal assembly) Tube, Long Tube, Short Tube, Transfer Valve, Stopcock (3-way) Exploded View of JE-5.0 Parts with Part Numbers Washer, Flat (bearing housing to support plate) Washer, Flat (bearing housing to support plate) Washer, Flat (seal housing) Washer, Spring (retaining plate) Washer, Spring (support plate to seal housing) Washer, Spring (bearing assembly, 3 required) “Y” Hose Fitting Flash Tube Beckman Coulter High Performance Centrifuges 1-65 1 www.beckmancoultercentrifugation.com Tubes and Bottles Tubes and Bottles for Every Application N 2 o single tube design or material will meet all application requirements. A number of factors should be considered when a supply of tubes is ordered: the particular technique to be used, the nature of the sample and any solvent or gradient media, the desirability of reusing the tubes, and certain convenience factors. The properties listed below provide a guide for anyone involved in the tube selection process. • Strength and Flexibility, to resist permanent deformation even when run in fixed angle rotors without tube caps • Chemical Resistance to a wide range of bases, acids, and solvents • Transparency to permit a clear view of fractions and bands after centrifugation • Thin enough to be sliced or punctured after centrifugation for fraction collection • Impermeable to Water to prevent aqueous solutions from permeating the tube wall and reaching the rotor cavity • Surface Properties that prevent the adherence of nucleic acids and proteins • Temperature Tolerance throughout a wide range of operating temperatures, without deforming at high temperatures or cracking when used close to 0°C • Autoclavable for convenient sterilization and reuse • Contaminant-free to avoid leaching extraneous materials into the sample, especially materials visible in the sensitive 240-280 nm range • Odor-free for pleasant handling The full line of Beckman Coulter tubes includes a number of tube materials, each with its own distinct combination of properties to meet a variety of application requirements. Available are transparent, translucent, and opaque tubes; tubes that can be sliced or punctured; tubes that can be sterilized and reused; and tubes that are resistant to a variety of chemical compounds. Beckman Coulter High Performance Centrifuges 2-1 www.beckmancoultercentrifugation.com Tubes and Bottles Tube Selection Considerations Compatibility of Tube Material with Solvents and Sample 2 The chemical compatibility of the tube materials with the gradientforming medium or other solvent is a prime consideration. Neutral sucrose and salt solutions cause no problem. But alkaline solutions, such as those frequently used for the separation of single-stranded forms of DNA, cannot be used in Ultra-Clear tubes or polycarbonate tubes and bottles. Sometimes DMSO is used in preparation of sucrose gradients for sedimentation of denatured RNA. Polycarbonateand Ultra-Clear tubes are incompatible with DMSO, so polypropylene tubes should be used. The last column of the “Quick Reference Chart to Tube Materials and Their Properties” on page 2-3 gives some guidelines to the chemical resistances of the various tube materials. It must be emphasized, however, that other conditions of centrifugation (g-force, duration of run, etc.) have considerable effect on how well a tube material will withstand a particular solvent. Beckman Coulter publication IN-175, “Chemical Resistances for Beckman Coulter Centrifugation Products” (found on the Beckman Coulter web site at www.beckmancoultercentrifugation.com) provides more detailed information about the chemical resistances of the various tube materials. The wisest course is to test any questionable combination under operating conditions before making the actual run. The type of sample, in some cases, will affect selection of a specific tube material. DNA, in its denatured or single-stranded form, will adhere to the surface of some tube materials. Polypropylene would be the best choice. (Most of this work is done in highly alkaline media which are incompatible with polycarbonate.) Lipoprotein separations are most often done in Ultra-Clear tubes because they are clear and sliceable; these properties simplify fraction location and recovery by tube slicing. When small lipoprotein samples are to be recovered by a fractionating device and clear tubes are desirable, there are alternatives: cellulose propionate, polycarbonate, and Ultra-Clear tubes. Hazardous materials, either pathogenic or radioactive, should be centrifuged with extreme care. All possible precautions must be taken to avoid leakage of the sample into the rotor cavity during centrifugation. To determine the optimum tube material for your specific sample and gradient medium, refer to the quick reference chart on page 2-4. Gradient Formation and Fractionation When choosing a tube for a density gradient run, some thought should be given to gradient formation and fractionation. If the bands or zones formed during centrifugation are indistinct, they may not be visible through a translucent material such as polypropylene. If optimum band visualization is important, Ultra-Clear tubes or tubes of polycarbonate or cellulose propionate should be used. Whenever collection of bands or zones must be done by puncturing the tube or slicing, a thin, flexible tube wall is required. Ultra-Clear or polypropylene tubes should be used, depending on the need for transparency. 2-2 As there are currently no wettable plastic centrifuge tubes available, gradients should be loaded into plastic tubes from the bottom up to avoid mixing. High Temperature Centrifugation Although modern centrifuges and rotors can operate at temperatures as high as 45°C, one cannot assume that every tube can be safely run over 25°C. Stainless steel and glass are the only materials which will not experience some deformation when subjected to high temperatures and long centrifugation times. Plastic tubes undergo some degree of softening at temperatures higher than 25°C. Whether or not this will cause permanent deformation is not a question of temperature alone. The centrifugal force field used, the duration of the centrifugation, the type of rotor, and even the tube angle all have an effect. It’s obviously impossible to give exact temperature limits for plastic tubes when so many other variables are involved. The safest policy is to pretest the tubes under the actual experimental conditions, but with water, rather than a valuable sample. Tube Sizes Tube sizes as indicated in the following charts are nominal sizes, and may vary somewhat from actual filling capacities. If a thickwall tube is run uncapped, the maximum filling volume will depend on the tube angle of the rotor to be used. See appropriate rotor instruction manuals for maximum filling levels of tubes. Tube Cleaning, Sterilization, and Reuse If tubes are to be reused, special care must be taken during cleaning and sterilization. All tubes can be washed by hand with a mild detergent such as Solution 555 diluted 5-to-1 or 10-to-1 with water. This is particularly important for polycarbonate tubes and bottles which should not be exposed to a detergent with a pH higher than 8. Tubes and bottles should not be washed in commercial dishwashers as the detergents and high temperatures are too harsh. Solvents such as alcohol or acetone react unfavorably with many tube materials. If an organic solvent must be used in the cleaning procedure, consult bulletin IN-175 for a table of tube material/solvent compatibilities (or review the same document on the Beckman Coulter web site at www.beckmancoultercentrifugation.com). The method chosen for sterilization has direct bearing on the number of reuses one can expect from a tube. Tubes and bottles of polypropylene, polyethylene, and glass can all be autoclaved, although in general, cold sterilization methods are not as harsh as autoclaving. Cold sterilization is recommended for both polycarbonate and Ultra-Clear. Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com Tubes and Bottles Tube Closures If maximum reuse is a major consideration, either polypropylene (preferably thickwall) or polycarbonate tubes and bottles should be selected, and cold sterilization methods used. If these tubes are run completely filled in swinging bucket rotors, most of them can be reused a number of times. Chances of permanent deformation will be greater whenever the tubes are run in fixed angle rotors, without caps, and/or partially filled. All of these conditions tend to stress the centripetal edge of the tube unduly. All tubes that have been used or autoclaved previously must be individually examined for signs of deformation or cracking before using them again. When other considerations have been resolved, convenience may be a deciding factor. Without a doubt, the most convenient tube closure is none at all; none are required for tubes run in swinging bucket rotors. For tubes run in fixed angle rotors, alternatives to the standard tube cap assemblies are available. Bottles have three-piece cap assemblies which are easier to use than the more complex tube cap assemblies. Polycarbonate bottles are available for general-purpose fixed angle rotors, and are used frequently for differential centrifugation where band recovery is not a problem. Thickwall tubes can be run in all fixed angle rotors without caps, provided they are partially filled. (Refer to rotor manuals for more information on fill volumes.) When closed tubes are required, Beckman Coulter offers some innovative and convenient options. A Quick-Reference Chart to Tube Materials and Their Properties Property Thinwall Polypropylene Thickwall Polypropylene Ultra-Clear Polycarbonate Polypropylene Polyethylene Cellulose Propionate transparent translucent transparent transparent translucent transparent/translucent transparent Autoclaveable yes yes no yes** yes no no Puncturable yes no yes no no yes no Sliceable yes no* yes no no* no no* Reusable no yes no yes yes yes no Acids (dilute or weak) S S S M S S S Optical Acids (strong) U S U U S S U Alcohols (aliphatic) U S U U S S U U Aldehydes M M S M M S Bases S S U U S S U Esters U M U U M S M Hydrocarbons (aliphatic) U M U U S U S Hydrocarbons (aromatic and halogenated) U U U U M M S Ketones U M U U M M U Oxidizing Agents (strong) U U U M M M M Salts S S M M S S S S = satisfactory resistance M = marginal resistanceU = unsatisfactory resistance * Polypropylene, polycarbonate, and cellulose propionate tubes with diameters of 5 to 13 mm may be sliced using the CentriTube Slicer (PN 34796O) and appropriate adapter plate. ** Table life will be significantly reduced by autoclaving. Note: This information has been consolidated from a number of sources and is provided only as a guide to the selection of tube materials. Soak tests at 1 g (at 20°C) established the data for most of the materials; reactions may vary under the stress of centrifugation, or with extended contact or temperature variations. To prevent failure and loss of valuable sample, ALWAYS TEST SOLUTIONS UNDER OPERATING CONDITIONS BEFORE USE. Warning: Do not use flammable substances in or near an operating centrifuge. Beckman Coulter High Performance Centrifuges 2-3 2 www.beckmancoultercentrifugation.com Tubes and Bottles General Filling and Sealing Requirements for Tubes and Bottles Tube or Bottle Swinging-Bucket Rotors Fixed-Angle Rotors Thinwall tubes Within 2 to 3 mm of top Full with cap Thickwall tubes At least 1/2 full 1/2 full to max. capless level or full with cap Quick-Seal tubes Full and heat-sealed Full and heat-sealed Bottles Min. to max. (see rotor manual) with screw-on cap or cap assembly 1/2 full to max. (see rotor manual) with screw-on cap assembly Open-top tubes Within 2 to 3 mm of top Full with cap Quick-Seal tubes Not used Full and heat-sealed Thickwall tubes At least 1/2 full 1/2 full capless level or full with cap or cap assembly Bottles At least 1/2 full Min. to max. (see rotor manual) with screw-on cap or cap assembly Stainless Steel Tubes Any level Any level with cap or cap assembly Polypropylene Tubes and bottles At least 1/2 full 1/2 to max. capless level or full with cap or cap assembly Polyethylene Tubes At least 1/2 full 1/2 to max. capless level or full with cap or cap assembly Polytetrafluoroethylene Tubes and bottles (Teflon) At least 1/2 full 1/2 full to max. capless level or full with cap Polyphenylsulfone (PPSU) At least 1/2 full N/A Polypropylene 2 Ultra-Clear Polycarbonate 2-4 Container Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com Tubes and Bottles High-Performance and High-Capacity Bottles Nominal Capacity Size mm Material Bottle & Cap Assy Bottle with Screw-On Caps Bottle Only Insert Only O-ring Screw-On Cap Only 10 mL 16 x 80 PC N.A. 355672 N.A. N.A. N.A. N.A. 10 mL 16.1 x 81.1 PE N.A. 364695 N.A. N.A. N.A. N.A. 10 mL 16.1 x 81.1 PTFE N.A. 364693 N.A. N.A. N.A. N.A. 26.3 mL 25 x 89 PC 355616 N.A. 340382 335258 870385 335259 30 mL 25.3 x 92 PE 363073 N.A. N.A. N.A. N.A. N.A. 30 mL 25.3 x 92 PC N.A. 363070 N.A. N.A. N.A. N.A. 40 mL 29 x 104 PC N.A. 355628 N.A. N.A. N.A. N.A. 50 mL 28.5 x 107 PTFE* N.A. 363076 N.A. N.A. N.A. N.A. 50 mL 29 x 104 PE 357001 361694 357003 N.A. 358627 961582 356284 50 mL 29 x 104 PC 357000 361693 357002 N.A. 358627 961582 356284 70 mL 38 x 102 PC 355620 N.A. 355655 334545 870384 334547 85 mL 38 x 104 PC 363081 N.A. N.A. N.A. N.A. N.A. 85 mL 38 x 104 PP N.A. 364719 N.A. N.A. N.A. N.A. 363082 N.A. N.A. N.A. N.A. 100 mL 38 x 102 PP 355624 355624 355626 N.A. N.A. 355625 180 mL 55 x 104 PE N.A. 361245 N.A. N.A. N.A. N.A. 230 mL 62 x 141 PE 356989 N.A. 356988 N.A. N.A. 344691 230 mL 62 x 141 PC 356987 N.A. 356986 N.A. N.A. 344691 250 mL 62 x 120 W PC 356013 355673 358275 N.A. 927860 358977 250 mL 62 x 122 W PP 356011 N.A. 358326 N.A. 927860 358977 250 mL round bottom 62 x 136 PC N.A. 355673 N.A. N.A. N.A. 356261 500 mL 69 x 160 W PC 355605 355664 355649 334419 870411 356260 500 mL 69 x 160 W PP 355607 355665 355650 334419 870411 356260 500 mL 69 x 160 W PC 361690 N.A. 355649 N.A. 927860 360954 500 mL 69 x 160 W PP 361691 N.A. 355650 N.A. 927860 360954 750 mL 96 x 130 PC N.A. 358299 358297 N.A. N.A. 344693 750 mL 96 x 130 PP N.A. 356855 349815 N.A. N.A. 344693 1000 mL 95 x 191 PC A98812 N.A. 366751 393898 A98817 B10317 1000 mL 95 x 191 PP A98813 N.A. A98814 393898 A98817 B10317 1000 mL 95 x 191 PP B29896 N.A. A98814 393898 A98817 B29894 1000 mL 97 x 167 PC N.A. 355675 341984 N.A. N.A. 344693 1000 mL 97 x 167 PP N.A. 355676 341985 N.A. N.A. 344693 2 PA = Polyallomer PC = Polycarbonate PE = Polyethylene PP = Polypropylene PPSU = Polyphenylsulfone PTFE = Polytetrafluoroethylene C = Conical W = Wide-Mouth N.A. = Not Available * With high-speed screw-on caps. Beckman Coulter High Performance Centrifuges 2-5 www.beckmancoultercentrifugation.com Tubes and Bottles Adapters and Sleeves for Non-Beckman Coulter Tubes/Bottles* 2 Rotor Tube Vol. mm Size # of Places Number Part Rotor Tube Vol. Size mm # of Places Part Number JA-30.50 5 mL 7 mL 12 x 75 13 x 100 1 1 356970 356976 JA-10 JA-25.50 5 mL 7 mL 12 x 75 13 x 100 1 1 356970 356976 5 mL 7 mL 15 mL 15 mL 50 mL 50 mL 12 x 75 13 x 100 Conical Round-bottom Conical Round-bottom 10 9 5 5 1 1 356967 356973 356960 356994 356965 356996 JA-21 5 mL 12 x 75 1 356972 JA-20.1 5 mL 7 mL 12 x 75 13 x 100 1 1 356971 356977 JS-13.1 5 mL 7 mL 12 x 75 13 x 100 1 1 356970 356976 JA-20 5 mL 7 mL 12 x 75 13 x 100 1 1 356970 356976 JS-7.5 JA-18 5 mL 7 mL 15 mL 50 mL 12 x 75 13 x 100 Conical Conical 3 3 1 1 356969 356975 356962 356963 5 mL 7 mL 15 mL 50 mL 12 x 75 13 x 100 Conical Conical 9 8 4 1 356968 356974 356964 356966 JA-17 5 mL 7 mL 12 x 75 13 x 100 1 1 356970 356976 JS-4.2 & JS-4.2A 3 mL 15 mL 250 mL Conical Conical Conical 26 14 1 339100 339102 349849 JLA 16.250/ JA-14 5 mL 7 mL 15 mL 15 mL 50 mL 50 mL 12 x 75 13 x 100 Conical Round-bottom Conical Round-bottom 9 8 4 5 1 1 356968 356974 356964 356995 356966 356997 JLA-10.500 5 mL 7 mL 15 mL 15 mL 50 mL 50 mL 12 x 75 13 x 100 Conical Round-bottom Conical Round-bottom 10 9 5 5 1 1 356967 356973 356960 356994 356965 356996 Adapters for Glass Tubes in Beckman Coulter Rotors* Rotor Volume Tube Tube Material Part Number Adapter Rotor Tube Volume Tube Material Adapter Part Number JA-30.50 15 mL 30 mL Corex, Pyrex Corex 870329 870331 JS-13.1 30 mL 15 mL Corex Corex, Pyrex 870331 870329 JA-25.50 15 mL 30 mL Corex, Pyrex Corex 870329 870331 JS-7.5 JA-20.1 15 mL Pyrex 342643 150 mL 30 mL 15 mL Corex Corex Corex, Pyrex 339362 356997/870331 356995 JA-20/JA-17 15 mL 30 mL Corex, Pyrex Corex 870329 870331 JA-18 15 mL 30 mL Corex, Pyrex Corex 870329/347539 870331/347539 JA-14 150 mL 30 mL 15 mL 15 mL Corex Corex Corex Corex, Pyrex Conical 339362 356997/870331 356995 356964 JA-10.500 150 mL 30 mL 15 mL Corex 362750/339362 Corex 356996/870331 Corex, Pyrex Conical 356960 JA-10 150 mL 30 mL 15 mL Corex 362750/339362 Corex 356996/870331 Corex, Pyrex Conical 356960 * JS-4.2 & JS-4.2A 3 mL 15 mL 30 mL 150 mL Pyrex Conical 339100 Corex, Pyrex, 339102 Corex & Pyrex Conical and Conical Graduated Corex 341977 Corex 339108/ 339362 Check with tube manufacturer for maximum allowable g-force. 2-6 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com Tubes and Bottles Tubes and Bottles Used in High-Performance and High-Capacity Rotors Nominal Nominal Filling Size Capacity (mL) (mm) Inches Part No. Rotors Quick-Seal Polypropylene Tubes 100.0 38 x 102 1.5 x 4.0 345776 JA-18 345778 JA-18 Quick-Seal Ultra-Clear Tubes 100.0 38 x 102 1.5 x 4.0 Quick-Seal Bell-Top Tubes, Polypropylene 4.3 16 x 38 0.65 x 2.5 356562 JS-24.15 6.3 16 x 45 0.65 x 1.8 345830 JS-24.15 8.0 16 x 58 0.65 x 2.25 344621 JS-24.15 8.5 25 x 38 0.65 x 2.5 358652 (konical) JS-24.38 10.0 16 x 67 0.65 x 2.5 344622 JS-24.15 15.0 25 x 38 1 x 1.5 343664 JS-24.38 23.0 25 x 76 1 x 1.5 358654 (konical) JS-24.38 27.0 25 x 64 1 x 2.5 343665 JS-24.38 33.0 25 x 83 1 x 3.25 344623 JS-24.38 2 Open-Top Tubes, Polypropylene 15.0 16 x 96 0.65 x 3.85 361707 JS-24.15 25.0 25 x 76 1.0 x 3.0 358125 (konical) JS-24.38 30.0 25 x 89 1.0 x 3.5 358126 (konical) JS-24.38 38.5 25 x 89 1.0 x 3.5 326823 JS-24.38 Open-Top Tubes, Polypropylene, Thickwall 4.0 13 x 64 0.5 x 2.5 355644 JA-25.15 10.0 16 x 76 0.65 x 3.0 355640 JA-25.15, JA-21, JA-20.1, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 12.5 16 x 95 0.625 x 3.75 32.0 25 x 89 1.0 x 3.5 361708 (konical) JS-24.15 355642 JS-24.38 Open-Top Tubes, Polycarbonate 15.0 18 x 100 0.725 x 4.0 342080 JA-25.15, JA-20.1, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 50.0 29 x 104 1.125 x 4.0 363647 JA-30.50, JA-25.50, JA-20, JA-18, JA-17, JA-14, JLA-10.500, JA-10, JLA-9.1000, JLA-8.1000, JS-7.5, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 1000.0 95 x 191 366751 JLA-9.1000, JLA-8.1000 3.8 x 7.65 Open-Top Tubes, Polycarbonate, Thickwall 4.0 13 x 64 0.5 x 2.5 355645 JA-25.15 10.0 16 x 76 0.65 x 3.0 355630 JA-25.15, JA-21, JA-20.1, JS-13.1, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 32.0 25 x 89 1.0 x 3.5 355631 JS-24.38 342081 JA-25.15, JA-20.1, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 Open-Top Tubes, Polyethylene, Thickwall 15.0 18 x 100 0.725 x 4.0 Beckman Coulter High Performance Centrifuges 2-7 www.beckmancoultercentrifugation.com Tubes and Bottles Nominal Nominal Filling Size Capacity (mL) (mm) Inches Part No. Rotors Open-Top Tubes, Polypropylene, Thickwall 2 4.0 13 x 64 0.5 x 2.5 355645 JA-25.15 15.0 18 x 100 0.725 x 4.0 342082 JA-25.15, JA-20.1, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 50.0 29 x 104 1.125 x 4.0 357007 JA-30.50 Ti, JA-25.50, JA-20, JA-18, JA-17, JLA-16.250, JA-14, JLA-10.500, JA-10, JLA-9.1000, JLA-8.1000, JS-7.5, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 1000.0 95 x 191 A98814 JLA-9.1000, JLA-8.1000 3.8 x 7.65 Open-Top Tubes, Ultra-Clear 15.0 16 x 96 0.65 x 3.8 361706 JS-24.15 38.5 25 x 89 1.0 x 3.5 344058 JS-24.38 357448 - Natural JA-30.50 Ti, JA-25.50, JA-20, JA-18.1, JA-18, JS-13.1, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 363664 JA-30.50 Ti, JA-25.50, JLA-16.250, JA-14, JLA-10.500, JA-10, JLA-9.1000, JLA-8.1000, JS-13.1, JS-7.5, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 Tubes with Snap-On Caps, Polypropylene 1.5 11 x 38 0.4 x 1.5 Tubes with Snap-On Caps, Polycarbonate 50.0 29 x 104 1.125 x 4.0 Tubes with Snap-On Caps, Polypropylene 1.5 11 x 38 0.4 x 1.5 356090 - Natural JA-30.50 Ti, JA-25.50, JA-20, JA-18, JA-18.1, JS-13.1, JS-5.2, JS-4.2, JS-4.3, JS-4.2A, JS-4.0, JS-3.0 1.5 11 x 38 0.4 x 1.5 356091 - Blue JA-20, JA-18, JA-18.1, JS-13.1,JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 1.5 11 x 38 0.4 x 1.5 356092 - Green JA-20, JA-18, JA-18.1, JS-13.1,JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 1.5 11 x 38 0.4 x 1.5 356093 - Yellow JA-20, JA-18, JA-18.1, JS-13.1,JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 1.5 11 x 38 0.4 x 1.5 356094 - Orange JA-20, JA-18, JA-18.1, JS-13.1,JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 1.5 11 x 38 0.4 x 1.5 343169- Natural (cap separate) JA-18.1, JA-18, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 1.125 x 4.0 357005 - Natural (cap separate) JA-30.50 Ti, JA-25.50, JA-20, JA-17, JLA-16.250, JA-14, JLA-10.500, JA-10, JLA-9.10000, JLA-8.1000, JS-13.1, JS-7.5, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 340196 - Natural JA-20, JA-18.1, JA-18, JS-13.1, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 50.0 29 x 103 Tubes with Snap-On Caps, Polyethylene 1.8 11 x 39 0.4 x 1.5 Bio-Vial Tubes 4.0 14 x 55 .5625 x 2.25 566353 - Polypropylene JLA-16.250, JA-14, JLA-10.500, JA-10, JLA-9.1000, JLA-8.1000, JS-7.5, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 Bottles Only 70.0 38 x 102 1.5 x 4.0 355655 - Polycarbonate JS-5.2, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 100.0 38 x 102 1.5 x 4 355626 500.0 69 x 160 2.75 x 6.5 355649 - Polycarbonate JS-5.2, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 JS-5.2, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 500.0 69 x 160 2.75 x 6.5 355650 1000.0 95 x 191 3.75 x 7.5 366751 - Polycarbonate JLA-9.1000, JLA-8.1000 1000.0 95 x 191 3.75 x 7.5 A98814 - PolypropyleneJLA-9.1000, JLA-8.1000 2-8 JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com Tubes and Bottles Nominal Nominal Filling Size Capacity (mL) (mm) Inches Part No. Rotors Bottles with Cap Assemblies, Polypropylene 50.0 29 x 104 1.25 x 4.0 357001 JA-30.50 Ti, JA-20, JA-17, JLA-16.250, JA-14, JLA-10.500, JA-10, JLA-9.1000, JLA-8.1000, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 50.0 29 x 104 1.25 x 4.0 361694 JA-25.50, JA-17, JA-14, JS-5.2, JS-4.3, JS4.2, JS-4.2A, JS-4.0, JS-3.0 Bottles with Cap Assemblies, Polycarbonate 50.0 29 x 104 1.25 x 4.25 361693 JA-25.50, JA-17, JS-4.3 50.0 29 x 104 1.25 x 4.25 357000 JA-30.50 Ti, JA-20, JA-17, JLA-16.250, JA-14, JLA-10.500, JA-10, JLA-9.1000, JLA-8.1000, JS-7.5, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 70.0 38 x 102 1.5 x 4.0 355620 JA-18, JS-5.2, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 500.0 62 x 166 2.75 x 6.5 361690 JLA-10.500 250.0 62 x 122 358275 (wide mouth) JS-5.2, JS-4.2, JS-4.3, JS-4.2A, JS-4.0, JS-3.0 500.0 69 x 160 355605 (wide mouth) JA-10, JLA-9.1000, JLA-8.1000, JS-5.2, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 1000.0 95 x 191 A98812 JLA-9.1000, JLA-8.1000 2.5 x 4.75 2.75 x 6.5 3.8 x 7.65 2 Bottles with Cap Assemblies, Polypropylene 10.4 16 x 76 0.6 x 3.0 355603 JS-7.5 250.0 62 x 120 2.5 x 4.75 358326 (wide mouth) JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 500.0 69 x 160 2.75 x 6.5 355607 (wide mouth) JA-10, JLA-9.1000, JLA-8.1000, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 2.75 x 6.5 500.0 69 x 160 361691 JLA-10.500 1000.0 95 x 191 3.8 x 7.65 A98813 JLA-9.1000, JLA-8.1000 1000.0 95 x 191 3.8 x 7.65 B29896 JLA-9.1000, JLA-8.1000 Bottles with Screw-On Caps, Polypropylene 50.0 29 x 104 1.25 x 4.0 357003 JA-30.50 Ti, JA-25.50, JA-20, JA-18, JA-17, JLA-16.250, JA-14, JLA-10.500, JA-10, JLA-9.1000, JLA-8.1000, JS-13.1, JS-7.5, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 Bottles with Screw-On Caps, Polycarbonate 10.0 16 x 80 0.6 x 3.2 355672 JA-30.50 Ti, JA-25.50, JA-25.15, JA-21, JA-20.1, JA-20, JA-17, JS-13.1, JS-5.2, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 50.0 29 x 104 1.25 x 4.0 357002 JA-30.50 Ti, JA-25.50, JA-20, JA-18, JA-17, JLA-16.250, JA-14, JLA10.500, JA-10, JS-13.1, JS-7.5, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 230.0 62 x 141 2.5 x 5.25 356987 (conical) JA-14, JS-7.5, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 250.0 62 x 120 2.5 x 4.75 356013 (wide mouth) JLA-16.250, JA-14, JLA-10.500, JA-10, JLA-9.1000, JLA-8.1000, JS-7.5, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 250.0 62 x 136 2.5 x 5.5 355673 JS-7.5, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 500.0 69 x 160 2.75 x 6.5 355664 JS-5.2, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 750.0 96 x 130 3.75 x 5.25 358299 JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 1000.0 97 x 167 3.75 x 6.75 355675 JS-5.2, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 Bottles with Screw-On Caps, Polypropylene 100.0 38 x 102 1.5 x 4.0 355624 JA-18, JS-5.2, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 230.0 62 x 141 2.5 x 5.5 356989 (conical) JA-14, JS-7.5, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 250.0 62 x 120 2.5 x 4.75 356011 (wide mouth) JLA-16.250, JA-14, JLA-10.500, JA-10, JLA-9.1000, JLA-8.1000, JS-7.5, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 500.0 69 x 159 2.75 x 6.5 355665 JA-10, JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 750.0 96 x 130 3.75 x 5.25 356855 JS-5.2, JS-4.3, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 1000.0 97 x 167 4.0 x 6.75 355676 JS-5.2, JS-4.2, JS-4.2A, JS-4.0, JS-3.0 BottleswithScrew-OnCaps,Polytetrafluoroethylene(PTFE) 50.0 28.5 x 107 1.25 x 4.25 363076 Beckman Coulter High Performance Centrifuges JS-4.2 2-9 www.beckmancoultercentrifugation.com HarvestLine System Liners Unique design enhances productivity 2 HarvestLine disposable bottle liners provide a significant improvement in the centrifugation of biological material. HarvestLine System Liners save time in the handling and retrieval of sample. Used in Avanti Series centrifuges, these unique liners provide a convenient method of loading, recovering, and storing samples. HarvestLine liners can be sterilized (gamma radiation), placed in a freezer (-70°C) for prolonged storage, and are compatible with commonly used chemicals and solvents. They facilitate the harvesting of: • Mammalian and insect culture separations • Bacterial, yeast, and tissue homogenate isolations • Virus harvesting for vaccine production—viral vector gene therapy and monoclonal antibody production. HarvestLine System for JLA-8.1000 and JLA-9.000 Rotors JLA-8.1000 and JLA-9.1000 Fixed Angle Rotor with Liners The 6 x 1 liter JLA-8.1000 rotor system with liners is ideal for harvesting bacterial and yeast cell cultures from fermenters, clearing cell debris from homogenates, or purifying largevolume viruses and polysaccharides for vaccine production. The 4 x 1 liter JLA-9.1000 rotor provides up to 16 800 x g for high throughput. JS-5.0 Swinging Bucket Rotor with Liners The 4 x 2.25 liter JS-5.0 rotor with liners is ideal for greater sample throughput. Use this system to separate bacterial, yeast, and tissue homogenates. At 7 480 x g, the rotor harvests E. coli at a clearing rate of 99% in less than 10 minutes (throughput of better than 36 liters per hour). HarvestLine System for JS-5.0 Rotor Part Numbers 369264 369256 368735 HarvestLine System Liner Kit Includes369256one-literbottleliners(qty120),368740filling rack, 977472 funnel, and 369267 instructional CD. HarvestLine System Liners Fits JLA-8.1000 or JLA-9.1000 one-liter bottles (qty. 120). HarvestLine System Liners Fits JS-5.0 J-Wide Cups (qty. 50). Specifications Maximum Speed in the JS-5.0 rotor in the JLA-8.1000 rotor in the JLA-9.1000 rotor 5 000 rpm 8 000 rpm 9 000 rpm Maximum g-force in the JS-5.0 rotor in the JLA-8.1000 rotor in the JLA-9.1000 rotor 7 480 × g 15 970 × g 16 800 × g Run Time Up to 20 min. instrument set time Temperature Range 4° to 10°C Acceleration/Deceleration Up to instrument maximum settings 2-10 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com Tools and Supplies Tools and Supplies Rotor Cleaning Kit 339558 Rotor Cleaning Kit. Contains two 946-mL bottles of Solution 555 Rotor Cleaning Concentrate, 339379 Rotor Cleaning Brush, and 339380 Rotor Cleaning Brush Replacement Parts/Supplies 339555 Solution 555 Rotor Cleaning Concentrate (min. order two Bottles) 339379 Rotor Cleaning Brush, 5⁄8-in. (16 mm) and 1-in. (25.4 mm), for Rotor Cavity diameters from 7⁄16-in. (11 mm) to 1-in. (25.4 mm) (min. order three Brushes) 339380 Rotor Cleaning Brush, 11⁄4-in. (32 mm) and 11⁄2-in. (38 mm), for Rotor Cavity diameters from 1-in. (25.4 mm) to 11⁄2-in. (38 mm) (min. order three Brushes) Beckman Coulter High Performance Centrifuges 2-11 2 www.beckmancoultercentrifugation.com Reference Guide to Centrifuge Selection Centrifugation is a basic separation technique that is utilized at multiple stages in the study of sample components. Flexible rotor and adapter systems for each Beckman Coulter centrifuge allow them to be used across multiple application areas. To help you select the most appropriate centrifuge for your work, the following charts provide brief descriptions of the kinds of separations typically achieved using various centrifuges. These charts list frequent separation requirements for each sample type, and identify the centrifuges that are typically used to meet those requirements. In addition to the separation and isolation of sample particles, centrifugation is increasingly being used as an analytical technique for the study of macromolecular interactions and the determination of molecular weights. Instruments for these applications are also listed below. Quick-Reference Guide to Centrifuge Selection Proteins Ammonium sulfate precipitates Centrifugal filtration Avanti J 3 Centrifuges Typically Used • • Avanti J-HC Specific Application J6-MI Materials to Be Isolated • • Subcellular Fractions Chromatin/Nucleosomes Sucrose gradient isolation Microsomes Pelleting Sucrose gradient isolation Microsomal membrane fractionation Mitochondria Pelleting Sucrose gradient isolation Nuclei Pelleting Membranes Pelleting Sucrose/Percoll gradient fractionation Binding studies Ribosomes/Polysomes Pelleting Size fractionation in sucrose gradients Cytosol Clarification 3-2 • • • • • • • • • • • • • • • • • • • • • Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com Reference Quick-Reference Guide to Centrifuge Selection (continued) • • • • • Preparative Centrifugation Lysates/Homogenates Nucleic Acids DNA RNA Cells Viruses Blood Clearing debris and large particles • Alcohol precipitation Phenol/CHC13 extraction Size fractionation in sucrose gradients Minipreps in 96-well plates Spin columns • • • • Plasma preparation Blood-cell products Beckman Coulter High Performance Centrifuges • • Phenol/CHC13 extraction Alcohol precipitation Lithium precipitation Isolation of mononuclear cells on Ficoll-Hypaque Pelleting bacteria Pelleting mammalian cells Elutriation of viable cells Other density gradient separations Pelleting PEG precipitates Density gradient isolations Avanti J-HC Centrifuges Typically Used J6-MI Specific Application Avanti J Materials to Be Isolated 3 • • • • • • • • • • • • • • • • • • • • 3-3 www.beckmancoultercentrifugation.com Reference Useful Formulas k Factor To determine k factor k= To determine pelleting time (t) t= To relate pelleting time between rotors ln (rmax/rmin) ω2 k s 10-13 3600 OR k= 2.53 × 105 ln (rmax/rmin) (RPM/1000)2 where s = sedimentation coefficient in Svedbergs k1 k = 2 t1 t2 To adjust k factor for runs less than maximum rotor speed 3 × kadj = k rated speed of rotor ( maximum ) actual run speed 2 To relate relative centrifugal force (RCF) to speed (RPM): RCFmax = 1.12 rmax ( RPM ) OR RPM = 10 1000 2 3 RCF 1.12rmax To relate the sedimentation coefficient (s) to rotational speed: s= 1 dr × ω2r dt Svedberg unit (S) equivalent: S = 10-13 seconds Reduced run speed for dense solutions: reduced run speed = max rated speed of rotor × A B where A = max. permissible density of rotor tube contents, and B = actual density of the tubes to be centrifuged 3-4 Beckman Coulter High Performance Centrifuges www.beckmancoultercentrifugation.com Support Services Field Service Support Most of us appreciate the need for careful design, handling, and maintenance of certain kinds of laboratory equipment— the optics of a spectrophotometer, for example. It may not be obvious, however, that anything as substantial looking as a centrifuge rotor must be properly maintained during use in order for it to fulfill its life expectancy. If you consider that, during rotation, a High-Performance Centrifuge Rotor may experience more than 110,000 times the force of gravity, it becomes apparent that seemingly minor flaws will assume much greater significance at these g–forces. In effect, one gram will “weigh” 110 kilograms, and a tiny flaw in a critical part may generate stresses greater than the rotor was designed to withstand. We at Beckman Coulter maintain stringent quality standards and rigorously test every rotor design. Specific instructions for care and maintenance are included in the rotor manual that accompanies each rotor. And our Field Rotor Inspection Program is available at no charge to all users of Beckman Coulter High-Performance Centrifuges and Ultracentrifuges. 4 Field Rotor Inspection Program. What Is It? Our Field Rotor Inspection Program (FRIP) has two purposes: to prevent premature rotor failures by detection of stress corrosion, metal fatigue, wear or damage to anodized coatings; and to instruct laboratory personnel in the proper care of rotors. Contact your local Beckman Coulter Service Office for details on the Field Rotor Inspection Program. Using nondestructive methods (fiber optics borescopy and dyepenetrant analysis), they may find signs of corrosion or other damage. If so, they will recommend repair or replacement, and a potentially costly failure may be prevented. To give a fuller understanding of rotors, a comprehensive slide presentation is also offered. Centrifuge users are informed about maintenance procedures, rotor damage, and its significance. The stress corrosion of aluminum rotors, in particular, can be greatly reduced by good laboratory practice. For more information about the Field Rotor Inspection Program (FRIP), please go to: http://www.beckmancoulter.com/FRIP. Sometimes rotor corrosion is so bad it can be seen by the naked eye, while at other times it is not so apparent. If you have doubt about the condition of a single Beckman Coulter 4-2 3-6 rotor, you may return it to the factory where it will be inspected free of charge by our metallurgists. The rotor will be examined by a variety of nondestructive methods, including ultrasound which is capable of detecting internal flaws. Before shipping the rotor, you must contact the nearest Beckman Coulter Sales and Service office for specific instructions. A written statement must accompany each rotor, indicating that it is safe to handle, (i.e. free of any pathogenic or radioactive contamination). Rotor Safety Seminars To help you get the most from your Beckman Coulter rotors, Rotor Safety Seminars are frequently presented by our Field Service engineers. Seminars are designed to remind centrifuge users about the importance of proper rotor care and maintenance. When you attend a Beckman Coulter Rotor Safety Seminar, you will have an opportunity to ask questions that are specific to your particular situation, and you will learn: • What causes corrosion in a rotor, where it starts, what it does to the rotor, and how to avoid it • The proper way to clean and store rotors • How to get longer life from your rotor On-Site Rotor Inspection and Maintenance Specially trained Beckman Coulter Field Service engineers are available at your request for on-site inspection and minor rotor maintenance. Rotors that are free of biological and radiological contamination can be brought to these sessions for immediate inspection so you can continue operating your centrifuge with confidence in the condition of your rotors. A Comprehensive Approach to Centrifuge System Care Throughout the world, Beckman Coulter Field Service engineers are on hand to provide the support you need. So you can operate your centrifuges worry-free, a number of programs are in place that cover preventive maintenance of your system, including parts, labor, drive systems, and rotors. It all adds up to a comprehensive approach to maximizing your system investment. Contact your local Beckman Coulter Sales and Service office to find out the specifics about the program available in your area. Beckman Coulter High Performance Centrifuges .fr lter ou anc ckm be ww. w Beckman Coulter France S.A.S. Paris-Nord 2 22, Av. des Nations B.P. 54359 – Villepinte 95942 Roissy CDG Cedex www.beckmancoulter.fr [email protected]
© Copyright 2024 ExpyDoc