561-MB24 - Honeywell Security Group

561-MB24
Intruder Alarm Control Panel
Maximum security for all eventualities
The intruder alarm control panel 561-MB24 is designed
for use in private and commercial buildings and is highly
suitable for setting up medium-sized security systems.
It complies with the guidelines of the VdS Security
Class C as well as the German Electrical Standards 0833.
The intruder alarm control panel 561-MB24 has also
an approval according VSÖ-Class WS, approval no.
W031210/86E.
The control panel has an event memory for 15.000 events
which can be displayed via LCD operating units and
graphic operating units as well as the software WINFEM
Advanced. The event memory can also be printed out via
WINFEM Advanced.
The standard version has the following performance
features:
• 1 block lock terminal
• 8 conventional detector group inputs
• 63 BUS-1 users connectable
• 64 BUS-2 users connectable
• 24 detector groups programmable
• Integrated, monitored alarm signalling device terminals
A total of 24 detector groups can be realised with a possibility of up to 8 conventional detector group inputs as
standard.
Of these, several detector group inputs and/or BUS users
can be allocated to one detector group. This makes it
possible to establish logical relationships of the individual
detector groups to the object-specific circumstances
without any problems.
In conjunction with the evaluation unit IK3 and/or door
control module BUS-2 and the access control software
IQ MultiAccess or IQ SystemControl the connection of
mifare DESFire EV1 readers is possible.
In this combination the mifare DESFire EV1 readers
feature an enormous security increase. In the USA this
technique is approved for government documents with
highest security level.
Features
• 1 main zone with max. 7 secondary zones
2 main zones with a total of 6 secondary zones
• 1 to 24 detector groups (freely programmable)
• 24 detector group texts
• Sensitivity of detector groups programmable and
automatic adjustment of the detector groups
• Max. 8 external switching devices
• Up to 16 operating units on BUS-2
• 16 operating codes
• 32 IDENT-KEY data carrier manageable
• 64 room/time zones programmable
• 10 links, 20 macros for special functions
• Up to 15.000 events in event memory with date
and time
• Remote control and remote paramterization
• Standard programming for individual program
parts possible
• Easy firmware update due to Flash-memory
• In conjunction with a transmission device DS 9600,
DS 6600, DS 6700, DS 6750, DS 7600, DS 7700 or
DS 9500 a comfortable programming via USB is
possible
• Integration of mifare DESFire EV1 readers for
highest security standards possible
• In conjunction with the MB RF-system up to
64 RF devices possible
• Electronic fittings and cylinders applicable
• Use of the Honeywell MB-Remote Control App
for Android/iOS for display of panel state as well
as remote operation of the panel by simulating an
operating device in combination with a transmission device DS 6700, DS 6750 or DS 7700
• In conjunction with proX key switches designable
as amok alarm control panel with up to 16 activation units
High-level programming
Complete programming of the control panel is done via a
Windows PC/laptop using the parameterization software
WINFEM Advanced. This software can be used not only
for programming the control panel but also for backup of
the programming in the WINFEM database or as a file.
The programming files can also be used as base for other
control panels and can be adapted object-related.
This allows similar programming (e.g. control panels of a
multiple shop) to be created comfortably and efficiently.
Since the 561-MB24 is equipped with the option of
changing the language for operating and display texts, it
can also be used internationally. Many language versions
have already been developed and implemented in the
control panel.
In connection with a transmission device, remote programming or remote operation is possible. Depending on
the local conditions, transmission/communication can
take place via the analog telephone network or the ISDN
telephone network. When using a DS 6700, DS 6750 or
DS 7700 transmission device, remote programming/operation can also take place directly via a TCP/IP network.
Are the transmission units combined with the accessory
unit RFW-4000, remote programming/operation is also
possible via GSM / GPRS.
The user software IQ SystemControl allows the user to
carry out programming comfortably at the user level and
master data management via a connected PC.
But also in the mobile
communication area, the
Android / iOS control panel-app for
smartphones/tablet PCs
provides access to the control
panel on any time.
Depending on configuration the app
can be used for display, operation
and/or programming.
Access control functions
In conjunction with the components of the IDENT-KEY
system, the control panel 561-MB24 provides extensive
access control functions.
Up to 32 IDENT-KEY data carriers can be managed by
the control panel 561-MB24.
Every single data carrier can be allocated different
access rights. The allocation of the IDENT-KEY data
carriers to individual or several room/time zones allows
very complex access right models to be created.
Operation made easy
The range of functions of the 561-MB24 control panel
goes from simple access rights at one door, access rights
combined with the right to arm/disarm, to multiple person
access control and the control of single entry access
portal systems (personnel interlock, turnstile).
At the user level, different operating unit versions provide
the optimum solution for each specific application. LED
operating units for simple operations and indications,
LCD operating units for text-guided operation and simple
programming of the control panel at the user level and
graphic operating units for menu-guided operation.
By coupling the control panel via the access control
software IQ MultiAccess, it can be integrated into existing
access control systems. IQ MultiAccess allows data
carriers to be created and managed and individual rights
to be allocated across several control panels and even
different locations.
Macro functions
Complex control tasks or the combination of several
operating functions are easy to realise with the aid of
so-called macros. The 561-MB24 has max. 20 of these
macros. Instead of carrying out a series of time-consuming operations manually, it is possible to have the desired task carried out automatically using a single macro.
unauthorized access through to amok alarm actuation
with personal identification. This personal identification is
possible by combining control panel - proX key switch,
since an alarm actuation can only be triggered with an
ident data carrier. Thus triggering a false alarm by unauthorized persons is excepted.
Time control
RF extension
Moreover, the 561-MB24 control panel is provided with
room/time zone function, which can be compared to a
highly complex and freely programmable timer. The
room/time zone function allows you to implement up to
64 independent switching programs (room/time zones).
The combination of room/time zones with the allocation of
programmable outputs or switching devices and data
carriers allow individual control tasks and time periods for
disarming operations and/or access rights to be created.
The comfortable public holiday calendar function allows
rights and control specifications to be suspended for
certain days.
The combination of the "MB" bidirectional radio system
with the control panel 561-MB24 offers the option of
integrating wireless monitoring technology into the
wire-bound BUS-2 system.
This also allows remote objects or rooms that do not allow
a conventional installation to be included in the monitoring concept of the 561-MB24 control panel.
School must be safe
Gun Rampage - a headline, whose appearing has greatly
increased in recent years. Within such a scenario, the
protection of students, teachers and staff has the highest
priority. Here holistic solutions can be created with the
control panel 561-MB48. From peripheral security of
the school building, room monitoring by passive infrared
motion detectors, access control functions to prevent
Open communication
With the optional integratable RS-232/RS-485 interface
card the connection of external systems to the intruder
alarm control panel 561-MB24 can be realized. The
interface card allows a bidirectional communication
(RS-232 Full-Duplex / RS-485 Half-Duplex) to output
alarms and states of the control panel to external
systems and control of the intruder alarm panel by
external systems.
Possible applications are smart links with building
management systems, heating, air conditioning, lighting
as well as display and control functions via building
management systems.
Options/accessory
RDT/ transmission devices
057872.20 Transmission device DS 9600
incl. mechanical kit 012835,
Telim + VdS 2465 + SMS + e*Message + speech
057860
Transmission device DS 6600,
Telim + Contact ID + e*Message (Nurton)
057650.20 Transmission device DS 7600 ISDN,
Telim + VdS 2465 + SMS + e*Message + speech
057651.20 Transmission device DS 7700 ISDN/IP,
Telim + VdS 2465 + SMS + e*Message
+ TCP/IP + speech
057871.20 Transmission device DS 9500,
Telim + VdS 2465 + SMS + e*Message + speech
057864
Transmission device DS 6700 PSTN/IP,
Telim + VdS 2465 + SMS + e-mail + e*Message
+ TCP/IP + speech
057865
Transmission device DS 6750 PSTN/IP,
Telim + VdS 2465 + SMS + e-mail + e*Message
+ TCP/IP + speech + Contact ID
012835
Mechanical kit for integration of
transmission devices in 561-MB24
BUS-2 operating units
012540.17 2 x 40-digit LCD operating unit; with flap*
012541.17 2 x 40-digit LCD operating unit; without flap*
012544.17 10-DG operating unit with disabling function*
012532.17 8-DG operating unit with disabling function
012542.17 16-DG disable and display module
012548.17 16-DG display module
012546.17 Flush mounting kit for 012532.17, 012541.17,
012542.17, 012544.17, 012548.17
013140
64 DG display terminal
010935
Compact operating
013002
Keypad TouchCenter Tuxedo, white
* Available in various languages
Control panel programming/operating
013498
PC parameterization software WINFEM
Advanced
026809
Zero modem cable
013466
PC-adapter cable
(only with Windows 98 and ME)
013467.10 USB adapter box (USB 1.1 compatible)
013595
WINFEM-User; Windows software for
programming on user-level
(up to IACP firmware version V08)
013596
IQ SystemControl; Windows software for
programming on user-level
(as of IACP firmware version V09)
013510
Honeywell MB-Remote Control App for
Android (as of Android version 2.1)
013515
Honeywell MB-Remote Control App for iOS
Communication
013211.10 RS-232/RS-485 Interface card
Technical data IACP 561-MB24
Rated connection voltage
Connection voltage range
Rated operating voltage
Current consumption at rated voltage
- disarmed, group connections – open
- per group connection (terminated with 12.1 kOhm)
Environmental class as per VdS
Protection class as per EN 60529
Operating temperature range
Storage temperature range
Dimensions (W x H x D in mm)
Weight (without options)
Colour
230 V AC / 50 Hz
230 V AC / -15% to +10%
12 V DC
100 mA
1 mA
II
IP 30
-5 °C to +45 °C
-25 °C to +70 °C
415 x 278 x 96
5,2 kg
light grey (similar to RAL 7035)
For further details as well as information to BUS-1 and BUS-2 users please refer to the product catalogue.
Order data IACP 561-MB24
012830
IACP 561-MB24
-approval: G103013 (IDT), Class C; Z105003 (AC), Class C;
-approval: W 031210/86 E, Class WS
Max. accumulator 2 x 6,5 Ah or 1 x 17 Ah.
Computer-/connection PCB 011890.01 with integrated power supply/charger unit, metal housing
012831
IACP 561-MB24, bundle with LCD operating unit
-approval: G103013 (IDT), Class C; Z105003 (AC), Class C;
-approval: W 031210/86 E, Class WS
Intruder alarm control panel (012830); 2 x 40 digit LCD operating unit (012540.17)
012832
IACP 561-MB24, bundle with LED operating unit
-approval: G103013 (IDT), Class C; Z105003 (AC), Class C;
-approval: W 031210/86 E, Class WS
Intruder alarm control panel (012830); 10 DG operating unit with disabling function (012544.17)
012833
IACP 561-MB24, bundle with LCD operating unit, DS 9600 ISDNtransmission device and IK3 evaluation unit BUS-2
-approval: G103013 (IDT), Class C; Z105003 (AC), Class C;
-approval: W 031210/86 E, Class WS
Intruder alarm control panel (012830); DS 9600 ISDN-transmission device (057872.20);
IK3 evaluation unit BUS-2 (023312.10); 2 x 40 digit LCD operating unit (012540.17)
012834.10 IACP 561-MB24, bundle with BUS-2 Keypad TouchCenter
Tuxedo, white and IK3 evaluation unit BUS-2
-approval: G103013 (IDT), Class C; Z105003 (AC), Class C;
-approval: W 031210/86 E, Class WS
Intruder alarm control panel (012830); BUS-2 Keypad TouchCenter Tuxedo, white (013002);
IK3 evaluation unit BUS-2 (023312.10)
Honeywell Security Group
Novar GmbH
Joh.-Mauthe-Straße 14 · 72458 Albstadt
Phone + 49 (0) 74 31/ 801- 0 · Fax 801-12 20
www.honeywell.com/security/de
[email protected]
P00164-22-0G0-17
05. 2014 · Subject to change without notice.
© 2014 Honeywell International Inc.