561-MB24 Intruder Alarm Control Panel Maximum security for all eventualities The intruder alarm control panel 561-MB24 is designed for use in private and commercial buildings and is highly suitable for setting up medium-sized security systems. It complies with the guidelines of the VdS Security Class C as well as the German Electrical Standards 0833. The intruder alarm control panel 561-MB24 has also an approval according VSÖ-Class WS, approval no. W031210/86E. The control panel has an event memory for 15.000 events which can be displayed via LCD operating units and graphic operating units as well as the software WINFEM Advanced. The event memory can also be printed out via WINFEM Advanced. The standard version has the following performance features: • 1 block lock terminal • 8 conventional detector group inputs • 63 BUS-1 users connectable • 64 BUS-2 users connectable • 24 detector groups programmable • Integrated, monitored alarm signalling device terminals A total of 24 detector groups can be realised with a possibility of up to 8 conventional detector group inputs as standard. Of these, several detector group inputs and/or BUS users can be allocated to one detector group. This makes it possible to establish logical relationships of the individual detector groups to the object-specific circumstances without any problems. In conjunction with the evaluation unit IK3 and/or door control module BUS-2 and the access control software IQ MultiAccess or IQ SystemControl the connection of mifare DESFire EV1 readers is possible. In this combination the mifare DESFire EV1 readers feature an enormous security increase. In the USA this technique is approved for government documents with highest security level. Features • 1 main zone with max. 7 secondary zones 2 main zones with a total of 6 secondary zones • 1 to 24 detector groups (freely programmable) • 24 detector group texts • Sensitivity of detector groups programmable and automatic adjustment of the detector groups • Max. 8 external switching devices • Up to 16 operating units on BUS-2 • 16 operating codes • 32 IDENT-KEY data carrier manageable • 64 room/time zones programmable • 10 links, 20 macros for special functions • Up to 15.000 events in event memory with date and time • Remote control and remote paramterization • Standard programming for individual program parts possible • Easy firmware update due to Flash-memory • In conjunction with a transmission device DS 9600, DS 6600, DS 6700, DS 6750, DS 7600, DS 7700 or DS 9500 a comfortable programming via USB is possible • Integration of mifare DESFire EV1 readers for highest security standards possible • In conjunction with the MB RF-system up to 64 RF devices possible • Electronic fittings and cylinders applicable • Use of the Honeywell MB-Remote Control App for Android/iOS for display of panel state as well as remote operation of the panel by simulating an operating device in combination with a transmission device DS 6700, DS 6750 or DS 7700 • In conjunction with proX key switches designable as amok alarm control panel with up to 16 activation units High-level programming Complete programming of the control panel is done via a Windows PC/laptop using the parameterization software WINFEM Advanced. This software can be used not only for programming the control panel but also for backup of the programming in the WINFEM database or as a file. The programming files can also be used as base for other control panels and can be adapted object-related. This allows similar programming (e.g. control panels of a multiple shop) to be created comfortably and efficiently. Since the 561-MB24 is equipped with the option of changing the language for operating and display texts, it can also be used internationally. Many language versions have already been developed and implemented in the control panel. In connection with a transmission device, remote programming or remote operation is possible. Depending on the local conditions, transmission/communication can take place via the analog telephone network or the ISDN telephone network. When using a DS 6700, DS 6750 or DS 7700 transmission device, remote programming/operation can also take place directly via a TCP/IP network. Are the transmission units combined with the accessory unit RFW-4000, remote programming/operation is also possible via GSM / GPRS. The user software IQ SystemControl allows the user to carry out programming comfortably at the user level and master data management via a connected PC. But also in the mobile communication area, the Android / iOS control panel-app for smartphones/tablet PCs provides access to the control panel on any time. Depending on configuration the app can be used for display, operation and/or programming. Access control functions In conjunction with the components of the IDENT-KEY system, the control panel 561-MB24 provides extensive access control functions. Up to 32 IDENT-KEY data carriers can be managed by the control panel 561-MB24. Every single data carrier can be allocated different access rights. The allocation of the IDENT-KEY data carriers to individual or several room/time zones allows very complex access right models to be created. Operation made easy The range of functions of the 561-MB24 control panel goes from simple access rights at one door, access rights combined with the right to arm/disarm, to multiple person access control and the control of single entry access portal systems (personnel interlock, turnstile). At the user level, different operating unit versions provide the optimum solution for each specific application. LED operating units for simple operations and indications, LCD operating units for text-guided operation and simple programming of the control panel at the user level and graphic operating units for menu-guided operation. By coupling the control panel via the access control software IQ MultiAccess, it can be integrated into existing access control systems. IQ MultiAccess allows data carriers to be created and managed and individual rights to be allocated across several control panels and even different locations. Macro functions Complex control tasks or the combination of several operating functions are easy to realise with the aid of so-called macros. The 561-MB24 has max. 20 of these macros. Instead of carrying out a series of time-consuming operations manually, it is possible to have the desired task carried out automatically using a single macro. unauthorized access through to amok alarm actuation with personal identification. This personal identification is possible by combining control panel - proX key switch, since an alarm actuation can only be triggered with an ident data carrier. Thus triggering a false alarm by unauthorized persons is excepted. Time control RF extension Moreover, the 561-MB24 control panel is provided with room/time zone function, which can be compared to a highly complex and freely programmable timer. The room/time zone function allows you to implement up to 64 independent switching programs (room/time zones). The combination of room/time zones with the allocation of programmable outputs or switching devices and data carriers allow individual control tasks and time periods for disarming operations and/or access rights to be created. The comfortable public holiday calendar function allows rights and control specifications to be suspended for certain days. The combination of the "MB" bidirectional radio system with the control panel 561-MB24 offers the option of integrating wireless monitoring technology into the wire-bound BUS-2 system. This also allows remote objects or rooms that do not allow a conventional installation to be included in the monitoring concept of the 561-MB24 control panel. School must be safe Gun Rampage - a headline, whose appearing has greatly increased in recent years. Within such a scenario, the protection of students, teachers and staff has the highest priority. Here holistic solutions can be created with the control panel 561-MB48. From peripheral security of the school building, room monitoring by passive infrared motion detectors, access control functions to prevent Open communication With the optional integratable RS-232/RS-485 interface card the connection of external systems to the intruder alarm control panel 561-MB24 can be realized. The interface card allows a bidirectional communication (RS-232 Full-Duplex / RS-485 Half-Duplex) to output alarms and states of the control panel to external systems and control of the intruder alarm panel by external systems. Possible applications are smart links with building management systems, heating, air conditioning, lighting as well as display and control functions via building management systems. Options/accessory RDT/ transmission devices 057872.20 Transmission device DS 9600 incl. mechanical kit 012835, Telim + VdS 2465 + SMS + e*Message + speech 057860 Transmission device DS 6600, Telim + Contact ID + e*Message (Nurton) 057650.20 Transmission device DS 7600 ISDN, Telim + VdS 2465 + SMS + e*Message + speech 057651.20 Transmission device DS 7700 ISDN/IP, Telim + VdS 2465 + SMS + e*Message + TCP/IP + speech 057871.20 Transmission device DS 9500, Telim + VdS 2465 + SMS + e*Message + speech 057864 Transmission device DS 6700 PSTN/IP, Telim + VdS 2465 + SMS + e-mail + e*Message + TCP/IP + speech 057865 Transmission device DS 6750 PSTN/IP, Telim + VdS 2465 + SMS + e-mail + e*Message + TCP/IP + speech + Contact ID 012835 Mechanical kit for integration of transmission devices in 561-MB24 BUS-2 operating units 012540.17 2 x 40-digit LCD operating unit; with flap* 012541.17 2 x 40-digit LCD operating unit; without flap* 012544.17 10-DG operating unit with disabling function* 012532.17 8-DG operating unit with disabling function 012542.17 16-DG disable and display module 012548.17 16-DG display module 012546.17 Flush mounting kit for 012532.17, 012541.17, 012542.17, 012544.17, 012548.17 013140 64 DG display terminal 010935 Compact operating 013002 Keypad TouchCenter Tuxedo, white * Available in various languages Control panel programming/operating 013498 PC parameterization software WINFEM Advanced 026809 Zero modem cable 013466 PC-adapter cable (only with Windows 98 and ME) 013467.10 USB adapter box (USB 1.1 compatible) 013595 WINFEM-User; Windows software for programming on user-level (up to IACP firmware version V08) 013596 IQ SystemControl; Windows software for programming on user-level (as of IACP firmware version V09) 013510 Honeywell MB-Remote Control App for Android (as of Android version 2.1) 013515 Honeywell MB-Remote Control App for iOS Communication 013211.10 RS-232/RS-485 Interface card Technical data IACP 561-MB24 Rated connection voltage Connection voltage range Rated operating voltage Current consumption at rated voltage - disarmed, group connections – open - per group connection (terminated with 12.1 kOhm) Environmental class as per VdS Protection class as per EN 60529 Operating temperature range Storage temperature range Dimensions (W x H x D in mm) Weight (without options) Colour 230 V AC / 50 Hz 230 V AC / -15% to +10% 12 V DC 100 mA 1 mA II IP 30 -5 °C to +45 °C -25 °C to +70 °C 415 x 278 x 96 5,2 kg light grey (similar to RAL 7035) For further details as well as information to BUS-1 and BUS-2 users please refer to the product catalogue. Order data IACP 561-MB24 012830 IACP 561-MB24 -approval: G103013 (IDT), Class C; Z105003 (AC), Class C; -approval: W 031210/86 E, Class WS Max. accumulator 2 x 6,5 Ah or 1 x 17 Ah. Computer-/connection PCB 011890.01 with integrated power supply/charger unit, metal housing 012831 IACP 561-MB24, bundle with LCD operating unit -approval: G103013 (IDT), Class C; Z105003 (AC), Class C; -approval: W 031210/86 E, Class WS Intruder alarm control panel (012830); 2 x 40 digit LCD operating unit (012540.17) 012832 IACP 561-MB24, bundle with LED operating unit -approval: G103013 (IDT), Class C; Z105003 (AC), Class C; -approval: W 031210/86 E, Class WS Intruder alarm control panel (012830); 10 DG operating unit with disabling function (012544.17) 012833 IACP 561-MB24, bundle with LCD operating unit, DS 9600 ISDNtransmission device and IK3 evaluation unit BUS-2 -approval: G103013 (IDT), Class C; Z105003 (AC), Class C; -approval: W 031210/86 E, Class WS Intruder alarm control panel (012830); DS 9600 ISDN-transmission device (057872.20); IK3 evaluation unit BUS-2 (023312.10); 2 x 40 digit LCD operating unit (012540.17) 012834.10 IACP 561-MB24, bundle with BUS-2 Keypad TouchCenter Tuxedo, white and IK3 evaluation unit BUS-2 -approval: G103013 (IDT), Class C; Z105003 (AC), Class C; -approval: W 031210/86 E, Class WS Intruder alarm control panel (012830); BUS-2 Keypad TouchCenter Tuxedo, white (013002); IK3 evaluation unit BUS-2 (023312.10) Honeywell Security Group Novar GmbH Joh.-Mauthe-Straße 14 · 72458 Albstadt Phone + 49 (0) 74 31/ 801- 0 · Fax 801-12 20 www.honeywell.com/security/de [email protected] P00164-22-0G0-17 05. 2014 · Subject to change without notice. © 2014 Honeywell International Inc.
© Copyright 2024 ExpyDoc