43581 Nilan VPL 15-28 UK.indd - Nilan outstanding Indoor Climate

M A R K E T L E A D I N G CO M M E R CI A L A N D D O M E S T I C V E N T I L AT I O N W I T H H E AT R E CO V E R Y
... high
performance
for private
homes
Nilan
VPL 15-28
Active heat recovery
with cooling
(air-to-air)
Nilan VPL 15-28
Domestic ventilation with heat recovery and cooling
(air to air)
Nilan VPL 15-28 are tried and tested heat recovery units with cooling
designed for use in dwellings of up to 700 m².
Function
Nilan VPL 15-28 are active heat recovery units with cooling for extracting
hot, humid air from kitchens, bathrooms, utility rooms, etc. Dust particles,
moisture and smells are thus removed from the home, ensuring a comfortable indoor climate.
The energy of the exhaust air is recovered and transferred to the inlet air
by means of a heat pump capable of extracting energy direct from the
exhaust air. The units can be supplied with a filter unit with built-in heat
pipe, thus significantly reducing the need for post heating. The units can
also be equipped with post-heating coils for connection to an electricity
supply or the central heating system.
In summer, the process is reversed and the incoming air is cooled.
Nilan VPL 15-28 consist of two energy-efficient EC fans for inlet and
exhaust respectively, a heat pump and a compressor.
Nilan VPL 15-28 are equipped with four-step EC fans capable of providing
up to 1000 m³/h (at 100 Pa). The units are operated via electronic CTS
600 control.
All units are powder coated in white.
Benefits
Nilan VPL 15-28 are compact units designed for use in private homes
where ventilation systems with highly efficient heat recovery and cooling
is required. VPL 15-28 help establish a comfortable and healthy indoor
climate by preventing dampness, removing undesirable smells, reducing
allergy problems, etc.
VPL 15-28 are renowned for their low energy consumption, long service
life, and low installation costs. The units have been tested by the Danish
Technological Institute and approved by the Danish authorities.
VPL 15-28 control panel
Using a weekly program, the CTS 600 controls can
be set for night setback, extended bathroom ventilation (humidity controlled), or any other wishes the
user might have.
Models
Clear the air and
recover the heat
• VPL 15 T EC with cooling
Capable of replacing up to 325 m³/h
(at 100 Pa).
An ideal model for installation in
utility rooms, where it can be
mounted on the wall or in a standard
cupboard.
Heating capacity: 2,1 kW, curve
controlled
Cooling capacity: 1,0 kW, curve
controlled
• VPL 15 EC with cooling
Capable of replacing up to 325 m³/h
(at 100 Pa). The unit is supplied with
built-in filters.
The unit is a free-standing model for
loft or technical room installation.
Heating capacity: 2,1 kW, curve
controlled
Cooling capacity: 1,0 kW, curve
controlled
Facts
• Heat recovery
• Cooling
• Dwellings of up to 700 m2
• Capable of replacing up to 1000 m3 air per hour (at 100 Pa)
• Inlet and exhaust
• Optional filter unit with built-in heat pipe
• Duct connections: Ø250 mm / Ø160 mm
Benefits
• Reduced need for heating as the temperature of the incoming
air is higher than the room temperature.
• No draughts as there are no outside openings in the dwelling
(balanced ventilation in/out).
• No problems with moisture or smells
• Addition of fresh air, removal of stale air
• High heat recovery rates
• Relief of allergy problems
A pollen filter can be fitted to most
Nilan units, allowing those who suffer
from pollen allergy to keep their doors
and windows closed while “airing” their
homes via a Nilan system.
• VPL 28 EC with cooling
Capable of replacing up to 1,000 m³/h
(at 100 Pa).
The unit is a free-standing model for
technical room installation.
Available with CTS 5000 control if
communication with other systems is
required.
Heating capacity: 3,3 kW, modulating
Cooling capacity: 3,0 kW, modulating
M A R K E T L E A D I N G CO M M E R CI A L A N D D O M E S T I C V E N T I L AT I O N W I T H H E AT R E CO V E R Y
Nilan A/S
Nilanvej 2
DK-8722 Hedensted
Technical data
Tel. +45 76 75 25 00
VPL 15 T EC
w/cooling
Air flow at 100 Pa
external
back-pressure
VPL 15 EC
w/cooling
[email protected]
www.nilan.dk
m³/h
Dimensions (excl.
connectors) LxWxH mm
100-325
100-325
200-1.000
600x550x635
750x415x680
700x570x865
Total weight
kg
50
54
65
Amperage
A
1x10
1x10
1x10
Voltage
V
230
230
230
R 134 A
R 134 A
R 407 C
650
60
1100
Refrigerant
Charge quantity
Fax +45 76 75 25 25
VPL 28 EC
w/cooling
g
Heat pipe
Nilan FU 10/15 H and FU 25/28H are filter units with built-in heat pipe for VPL 15-28.
The heat pipe is used as a pre-heat exchanger. The main advantage of using a heat
pipe is that the need for post heating is significantly reduced, thus minimising operating costs. The heat pipe system is self regulating and has uniform recovery across the
entire surface, eliminating the need for complex, energy-dependent defrosting and
bypass systems.
Toutside
°C
-15
-12
-9
-6
-3
0
+3
Heat
output
kW
0,6
0,6
0,5
0,4
0,4
0,3
0,2
Toutlet
°C
-3
-1
+1
+2
+4
+6
+7
Air
pressure Heat
drop output
Pa
kW
15
1,1
15
1,0
15
0,9
15
0,7
15
0,6
15
0,5
15
0,3
HP 28
300 m³/h
Toutlet
°C
-4
-2
0
+1
+3
+5
+6
350 m³/h
Air
pressure Heat
drop output
Pa
kW
35
1,5
35
1,4
35
1,3
35
1,2
35
1,0
35
0,8
35
Toutlet
°C
-2
0
+2
+4
+5
+7
700 m³/h
Air
pressure Heat
drop output
Pa
kW
20
2,9
20
2,6
20
2,1
20
1,9
20
1,4
20
1,2
Toutlet
°C
-3
-1
0
+2
+3
+5
Air
pressure
drop
Pa
45
45
45
45
45
45
Nilan creates well-being
for your family!
grc.dk . 3 0 0 0 . 0 9 . 2 0 0 9 . 4 3 5 8 1
HP15