Control & Measurement Features D-SiC [ for use in UV-C monitoring systems (for UV values in "%") [ indirect "side-looking" UV-C detection - sensor is positioned alongside the lamps Abstract [ for low pressure applications - wide intensity range due to automated measuring range selection [ fail safe signal transmission, max. cable length 30m [ multi sensor operation by connecting additional sensors in parallel to the RS485 bus [ PC software and handheld device available - display and log measurement values - select protocol type (ModBus or ZCON) - set ModBus address use with ZED UV Monitors PRO11DPI-I, PRO16DPI-I, PRO21D-I, PRO30D-I, PRO30D-U Control Units ZCON, PLC* *via RS485/ModBus RTU ZED UV Cabinets UV-Compact D ZCAB ZED Accessories ZED SmartMeter handheld device ZED Sensor Configurator PC software Installation data supply voltage 12...24V DC sensitive element SiC diode spectral range 210 - 380nm aperture angle approx. 110° (laterally round) operation temperature 0 - 40°C (32 - 104°F) IP code IP40 body material stainless steel (sensor head: quartz) mounting to be mounted in a quartz tube dimensions sensor body: sensor head: length: wiring sensor cables available in several lengths 11/2015 Ø20mm x 65mm Ø14mm x 15mm 85mm www.z-e-d.com Follow me for detailed technical specification see datasheets at: www.z-e-d.com/d-sls C&M 4