Three Phase PSD 28 I = 28 A Rectifier Bridge V = 600

ECO-PACTM 1
Three Phase
Rectifier Bridge
PSD 28
IdAV
VRRM
= 28 A
= 600-1200V
Preliminary Data Sheet
VRSM VRRM
Type
VDSM VDRM
(V)
(V)
700 600 PSD 28/06
900 800 PSD 28/08
1300 1200 PSD 28/12
+
~H
~A
~N
K
Features
Symbol
Test Conditions
I*dAV
IFSM
TC = 100 °C,
∫ i2 dt
TVJ
TVJM
Tstg
VISOL
Maximum Ratings
(per module)
28
A
TVJ = 45 °C
t = 10 ms (50 Hz), sine
100
A
VR = 0
t = 8.3 ms (60 Hz), sine
106
A
TVJ = TVJM
t = 10 ms (50 Hz), sine
85
A
VR = 0
t = 8.3 ms (60 Hz), sine
90
A
TVJ = 45 °C
t = 10 ms (50 Hz), sine
50
A²s
VR = 0
t = 8.3 ms (60 Hz), sine
47
A²s
TVJ = TVJM
t = 10 ms (50 Hz), sine
36
A²s
VR = 0
t = 8.3 ms (60 Hz), sine
33
A²s
-40... + 150
150
°C
°C
-40... + 125
°C
2500
V∼
50/60 Hz, RMS t = 1 min
IISOL ≤ 1 mA
t=1s
Md
Mounting torque
Weight
typ.
(M4)
3000
V∼
1.5 - 1.8
14 - 16
16
Nm
lb.in.
g
Symbol
Test Conditions
IR
VR = VRRM, TVJ = TVJM
≤
0.3
mA
VR = VRRM, TVJ = 25°C
≤
5
mA
IF = 7 A,
≤
1.12
V
0.8
V
40
mΩ
VF
VTO
rT
RthJC
RthJH
ds
dA
a
Characteristic Value
TVJ = 25 °C
For power-loss calculations only
per diode; DC
per module
per diode; DC
2.3
0.39
2.8
K/W
K/W
K/W
per module
0.47
K/W
Creeping distance on surface
Creeping distance in air
Max. allowable acceleration
11.2
9.7
50
•
•
•
•
•
Package with DCB ceramic base plate
•
UL registered, E 148688
Isolation voltage 3000 V∼
Planar glass passivated chips
Low forward voltage drop
Leads suitable for PC board
soldering
Applications
•
•
•
•
Supplies for DC power equipment
Input rectifier for PWM inverter
Battery DC power supplies
Field supply for DC motors
Advantages
•
•
•
•
•
Easy to mount with two screws
Space and weight savings
Improved temperature and power
cycling capability
High power density
Small and light weight
Package style and outline
Dimensions in mm (1mm = 0.0394“)
mm
mm
m/s²
Data according to IEC 60747 refer to a single diode unless otherwise stated
*- for resistive load at bridge output
POWERSEM GmbH, Walpersdorfer Str. 53
D - 91126 Schwabach
Phone: 09122 - 9764 - 0 FAX: 09122 - 9764 - 20
 2005 POWERSEM reserves the right to change limits, test conditions and dimensions