Preliminary Datasheet Medline – EXM225 Series 2 25 W S IN G LE OU TPUT AC/DC M EDI CAL ADAPTOR Specifications INPUT Nominal voltage Voltage range Frequency Input current Leakage current Inrush current Power factor correction Isolation Isolation class OUTPUT Power Voltage/current Efficiency Line regulation Load regulation Output voltage Ripple and noise Transient response Overcurrent protection Overvoltage protection Max capacitive load Remote sense Over temp. protection GENERAL Switching frequency MTBF 100-240VAC. 90-264VAC. 47-63Hz, sine wave. 1-3A. <100mA at nominal load and input voltage. Ipeak <50A at 265VAC. PF>0.90. 4000 VAC, 1s prim-sec. 10 Mohm isolation prim-sec. Class II. At 40°C ambient temperature, min 225W at convection cooling derating to 50% power at 70°C. Peak power capacity up to 250 Watts available during limited time, duty and input voltage. See table. Up to 93%. ±1%. ±1% 0-100% load change measured without output cable. Fixed. Max 1% p-p, 0-20MHz. Max 1% deviation for a 25% load change at 1A/1ms. Output returns to within 1% regulation within 100mS without output cable. Trip point max 120% auto recovery, hiccup mode, straight current limit characteristics. Trip point approx at 120% shut down. 15.000mF. No. Yes, automatic recovery. 100-300kHz. >400,000 hrs at 25°C, 100% load, according to MIL-HDBK-217E. Acoustic noise Less or equal to 30dB(A) at a distance of 0.3m and in frequency range 1Hz to 20kHz. Lifetime expectation 60,000 hrs at 100% load and 100% duty cycle at 35°C average ambient temperature. Input connector C8. Integraded cable lock for 100Nm pull strength. Output connector Molex 39-01-2060 over moulded or equivalent. Output cable Exchangeable 1,8 meters 6x16AWG. Weight<750g. Dimensions Circular 190mm. Height: 45mm. Mating connector TBD. Mechanical typ Enclosed external adaptor. Plastic Polycarbonate UL94 V0-V2. Mechanical protection IP21. ColourWhite. Indicator “ON” indicates with LED. Features • Powerbox “one-step” conversion topology • High reliability • Low component count • Extra low leakage • Less than 0.3 watts in zero load consumption • “Floor-top” external adaptor • Exchangeable AC cable • Exchangeable DC cable • Dimensions 190mm circular, 45mm height • Designed for medical home care applications ENVIRONMENTAL Operating temperature 0°C to +40°C at 100% load. –10°C to 70°C at 50% load. Storage temperature –40°C to +85°C. Humidity 10-90% RH non-condensing. CoolingConvection. Operating vibration 2-200Hz, 0.27G, sweep cycle 10 time, 3 min ea. Direction X, Y, Z. Non-operating vibration 2-200Hz, 1.0G, sweep cycle 10 time, 3 min ea. Direction X, Y, Z. Shock 20G, 3 shocks on each axiz, no damage to be sustained. 20121029 MEDLINE www.powerbox.info Preliminary Datasheet Medline – EXM225 Series 2 25 W S IN G LE OU TPUT AC/DC M EDI CAL ADAPTOR STANDARDS Safety standards IEC60601-1 3rd Ed, UL60601-1. Approvals pending. EMC IEC60601-1-2 ed.3. IEC55011 B. IEC61000-3-2 class D at 0.5 Ohm AC mains impedance IEC61000-3-3 IEC61000-4-2, +6kV contact, +8kV air IEC61000-4-3, 3V/m IEC61000-4-4, +2kV on AC port, ± kV on signal ports IEC61000-4-5, ±2kV common mode, ±1kV differential mode IEC61000-4-6, 3V/m IEC61000-4-8, 3A/m IEC61000-4-11, 30%500ms, 60% 100ms, 95% 5sec. Performance criteria A, A, B Environmental efficiency Fulfilling Green Mode requirements from IEC60950-1, CEC Level V, EISA and ErP. Less than 0.3 Watts in zero load. MODEL OUTPUT CONT.OUTPUT CONT.OUTPUT PEAK OUTPUT MAX OUTPUT NUMBERVOLTAGECURRENTPOWERCURRENT POWER EXM 225 5218 EXM 225 5219 EXM 225 5221 12.2 V 15.2 V 24.4 V PendingPendingPending Pending PendingPendingPending Pending 9.4 A 225 W 11.5 A 280 W MEDLINE www.powerbox.info
© Copyright 2024 ExpyDoc