Commercial "HC" Series Specifications Models: HC-9, HC

Specifications
®
Models: HC-9, HC-12, HC-15, HC-18, & HC-24
Commercial "HC" Series Specifications
Certification
ASME certified Electric Boiler
UL Listed
Control Package
68009 - DCCP - Digital Commmercial Control Package - with
Energy-Savings idle setback feature for off-peak hours
7-Day Programmable
Digital Touch pad control, allows 6 daily programs using 24/7
clock
Programs both Max and Energy-Savings idle-back temperature
Steambather can easily switch from “Idle” to maximum settings
from outside steamroom.
The user bypass feature can be programmed from 0 – 60
minutes.
Rapid heat-up time from “Idle” to maximum temperatures.
Can program 2 steam rooms with one control (SRP required for
2nd room)
Locking keypad prevents unauthorized program changes.
Safety Features
Automatic Regulator Pressure Control
High Limit Pressure Control with Manual Reset
Pressure Gauge
Sight Glass Gauge
Check Valves
Drain Valve
Cool Sense Steam Head Cover
Low Water safety cut-off to deenrgize the heater in the event of
a low water condition
Automatic Microprocessor controlled water feed with stainless
steel probes
Specification Chart
Maximum
Model
kW
No.
HC-9
9
Cubic Foot
Product
Range
No.
400
Operating Pressure
Max. 15 PSI
Dimensions
HC-12
39" x 22" x 28"H
12
500
Water Feed
1/2" NPT
Steam Output
3/4" NPT
HC-15
Optional Equipment
68010 - SRP - Second Room Package
68014 - Automatic Blowdown Valve - 208V
68015 - Automatic Blowdown Valve - 480/240V
68016 - TA-100 Temperature Alert
68017 - Commercial Aroma Pump
68018 - Eucalyptus Aromatherapy Pure Oil - 1.1 liter bottle
68019 - Lavender Aromatherapy Pure Oil - 1.1 liter bottle
68005 - Commercial Stand
68007 - ASME Blowdown Tank
HC-18
Warranty
HC-24
HC series generators are warranted against defects in materials
and workmanship for a period of 1 year and labor for a period of 90
days from the date of purchase.
06/14
-1-
15
18
24
620
740
1000
Volts Phase Amps Breaker
Size
60900
240
1
38
50
60901
208
1
43
60
60902
240
3
22
30
60903
208
3
25
35
60904
480
3
11
15
61200
240
1
50
70
61201
208
1
58
80
61202
240
3
29
40
61203
208
3
33
45
61204
480
3
15
20
61500
240
1
63
80
61501
208
1
72
90
61502
240
3
36
45
61503
208
3
42
60
61504
480
3
18
25
61800
240
1
75
100
61801
208
1
87
110
61802
240
3
43
60
61803
208
3
50
70
61804
480
3
22
30
62400
240
1
100
125
62401
208
1
115
150
62402
240
3
58
80
62403
208
3
67
90
62404
480
3
29
40
Pub. No. 614-A
Specifications
Access Requirements
Models: HC-9 thru HC-24 with DCCP Control
30"
36"
40"
ss
Acc
ce
Ac
ess
Dimensional Drawing for Heavy Commercial Steam Generator (HC-9 thru HC-24)
Shown with optional
2nd control package
Steam Outlet #2
¾" NPT
Steam Valves may be
rotated by loosening
this union
Steam Outlet #1
¾" NPT
15psi
Safety Valve
¾" NPT Outlet
Operating
Pressure
Control
5½"
Sight
Glass
Assembly
Auxiliary
Manual Reset
Pressure Cutoff
60
80
40
USE
USE
0
100
120
20
F
140
psi
Power Switch
Pressure
Gage
CONTROL POWER
STEAM 1
F
AROMA 1 AROMA2
Water Solenoid,
Valve ¼"
17"
12VAC
STEAM 1
AROMA 2
Water Inlet,
Strainer
½" NPT
STEAM 2
WATER
Command Module
CR2032
SENSOR 1
DRAIN
SENSOR 2
HEATER
XLOW HIGH MGR CTL USER 2 USER 1
STEAM 2
Drain Outlet
Heater
Access
ASME
Data Plate
GND
RD
AROMA 1
1
Steam Solenoid
Switches (Shown
with optional 2nd
control package)
ASME Plate
Located Inside
24KW
208V
6⅜"
1" Manual Drain
Valve
21"
1" Optional Auto
Blowdown Valve
2⅜"
12½"
19"
Control Access
®
East Coast Office: 25 E. Union Ave., East Rutherford, NJ 07073 • Tel: 800-577-6478 • Fax: 201-933-0746
West Coast Office: Tel: 800-355-6478 • Fax: 661-940-1617
06/14
-2-
Pub. No. 714-A