SCOPE OF WORK 1. The agencies must visit the site for location to install the Air-handling & allied work before quoting your prices. 2. The work proposed under this tender includes supply,installation,testing & commissioning of 05 Nos double skin airhandling units with mixing box having cap.25000cfm each at terrace. 3. Providing & Fixing at site all main equipments associated with the system as asked under technical specifications. 4. To execute all incidencal work at site including material supply at site associated with ac system asked in technical specifications,Nature of such work will be sheet metal duct,chilled water piping and drain piping etc.incidental civil work,incidental electrical work,cable etc.at site for all manufactured items at work and also item fabricated at site. 5 Routine testing,pressure testing of complete AHUs at site. 6. Connected civil work such as foundation and other repair work inside AHU Room for installation of AHU/equipments in all respect. 7. Performance testing at site complete system as per various technical requirement as stipulated in performance testing clause. 8. Dismentling of existing 05Nos AHU including duct connection,pipe connections,pipe connection and taking out these from site under rebate item as per schedule of work. 9. Shifting/modification if any in electrical/cubical panel refixing the same alongwith the motor connection and AHU put in operation etc. 10. Supply,installation,testing & commissioning of allied work like Butterfly valves,balancing valves,Y-strainer,3-way mixing valve,Airvent etc and all other connected accessories. 11. The existing airhandling units at site i.e at terrace is equipped with 29 Nos units ,out of them 05Nos AHUs proposed for replacement which are in more critical conditions. 12. New chilled waterline with valves & fittings of 05 No.AHUs shall be connected with existing header ring laid for all 29No AHUs at terrace. 13. The drawings forming part of these specifications provide a feasible scheme for locating the equipment.The contractor may re-arrange the equipment for improving the layout and meeting the site conditions.All such changes shall,however be subject to the engineerincharge/consultant approvals.these drawing are not meant to be working drawings,which shall be prepared by the contractor as reqd.even if the work awarded to be separate agency for ducting and insulation work,it will be rensponsiblity of contractor to prepare the ducting drawing and get it approved by the engineer incharge/consultant for ducting work at site. 14. The Airhandling unit alogwith allied work shall be tested as per specification given in tender documents. 15. All 05 Nos AHUs shall be assembled inside of AHU Rooms. General Manager(Tech.) SCHEDULE OF EQUIPMENT PROPOSED S.No. Description Unit Condition of Services 1.0 Air Handling Units 25000CFM(Double Skin)withReturn air/fresh air mixing Box 1.1 Manufacturer Name -- 1.2 Model -- 1.3 Type of unit -- 1.4 Overall Dimension -- 1.5 Unit Base -- 1.6 Drain Pan -- 22Gauge,SS304 Tray insulated with 13mm closed cell nitril rubber 1.7 Access Door -- Fan section & Mixing Chamber 2.0 Panel 2.1 Pre-coated G.S.S/Powder coated outer skin -- 0.6mm 2.2 Plain G.S.S/Powder coated inner skin -- 0.6mm 2.3 Thickness of insulated Panel -- 2.4 Frame type -- 2.5 Frame material -- 3.0 Fan & Fan Motor 3.1 Fan type -- DIDW Backward Curved 3.2 Model -- BDB900/TM(CLI) 3.3 Operating condition -- Ducted 3.4 Air Volume -- 25000CFM 3.5 Static Pressure -- 65mmwg 3.6 Fan Total efficiency -- 81% 3.7 Fan static efficiency -- 75% 3.8 Fan speed -- 750-800 rpm Carrier /ETA/Zeco/edgetech/Waves Floor mounted G.S.S channel 25mm,CFC free PUF injected, density 40kg+ 2kg/cu.m Moduler Aluminium extruded 3.9 Noise level -- Less then 80dba 3.10 Fan to be certified by -- AMCA 3.11 Make of Fan -- Kruger/Greenheck 3.12 Type of Motor -- TEFC(IPP-55) 3.13 Motor -- D180L 15KW(20H.P) 3.14 4. 0 Make of Motor Coil Data -- Crompton/ABB/Havells 4.1 Make -- 4.2 Air Flow Rate -- 25000CFM 4.3 Coil Casing -- G.I 4.4 Material of Tube -- Copper 4.5 Tube Thickness -- 0.41mm 4.6 Tube Dia -- ½”(Half inches) 4.7 Coil face area -- 50 – 54 Sqfts 4.8 No. of Coil -- 2Nos 4.9 No.of Raw -- 6 raw deep 4.10 Header material -- MS 4.11 Test pressure -- 21kg/sqcm 4.12 Fins material -- Aluminium 4.13 Thickness -- 0.15mm 4.14 No.of fins per inch(FPI) -- 12Nos. 5.0 Type of Filter Section 5.1 Mixing Box -- To be included 5.2 Volume Control Damper -- For R/A inlet & F/A inlet To be included 5.3 Filters -- Washable synthetic 5.4 Efficiency of Pre-filter -- 90% down to 10 Microns 5.5 Make of filters -- Spectrum/Thermadyne/Athlete Carrier/ETA/Zeco/edgetech/Waves List of Approved `Makes' S.No. Items Acceptable Makes 1. Air-Handling Units : Carrier/ETA/Zeco/edgetech/Waves 2. DIDW Backward Curved Fan : 3. Cooling Coil : 4. Electric Motor : Crompton/ABB/Havells 5. Prefilter : Spactrum/Thermadyne/Athlete 6. Chilled Water M.S Pipe : Jindal,Hissar/Tata 7. G.I Drain Pipe : Jindal,Hissar/Tata 8. Butterfly Valve : Audco/Advance 9. Balancing Valve : Advance/Sant 10. Y-Strainer : Advance/Sant 11. Ball valve : Zoloto/Leader 12. SS Pressure Gauge : H.Guru/Emrald/Fiebig 13. Thermometer : H.Guru/Emrald/Fiebig 14. 3-Way Mixing Valve : Anergy/Honeywell 15. Auto Airvent : Anergy/Honeywell 16. G.I Sheet : Sail/Jindal/Tata 17. Glass wool Insulation : U.P.Twiga/Malanpur 18. Nitril Rubber Insulation : Armacell/Paramount 19. Aluminium Sheet : Balco/Nalco/Hindalco 20. Fire Damper : Servex/Carryaire/Ravistar Kruger/Greenheck Carrier/ETA/Zeco/edgetech/Waves Schedule of Work Sub - Upgradation of HVAC System at scope complex,7-Lodhi Road,New Delhi-110003. SH - Replacement of existing 05No AHUs installed at Terrace. S.No. 1 Deccription of items Unit Qty Rate Amount Dismentling of existing AHU's Dismentling of existing AHU's alongwith fittings supports etc. locating on terrace at a specified Space along with all accessories like pipes, valves, insulation, ducting etc. as per Direction of Engineerincharge. 5 No. 5 Air Handling Units Rates not to be quoted here 2 No. S.I.T.C of Double skin floor mounted chilled/Hot water Air-Handling Units with mixing box complete with DIDW Backward Curved fan suitable for static pressure of 65mmwg.& noise level should not exceed 76 dba at 1mtr with fan total efficiency not less than 80% ,Fan motor TEFC(IPP-55),15KW suitable for operation through existing star-delta starter panel as connection of motor with existing cable/control cables, Cooling coil 6row deep copper tube with vent/purging arrangement ,dia 12.5mm,thickness 0.41mm,al.fins12Nos FPI,Filter plenums with mixing box.drain pan of suitable depth 16G thick,SS304,insulated with closed cell polyurathene 10mm thick insulation,with necessary vibration isolation arrangements,fire retardant flexible connections and all other accessories i/c supply,return and fresh air dampers ,AHU complete in working conditions i/c wiring,foundation complete as per specifications and drawings etc as reqd and as per direction of engineer - Incharge. 25000 cfm AHU, SP,65mmwg. 3 Controls for AHUs Supply, fixing,testing & commissioning of controls complete with wiring etc. three way mixing valve with linkage and actuator, modulating termperature controller 80 mm dia etc. as required. 4 No. 5 Rmt 110 No. 10 No. 5 No. 5 Chilled water Piping 80 mm dia. 5. Supply, fixing, testing and commissioning of following sizes Butterfly,Balancing valves, Ystrainers in chilled water lines complete with companion flanges, nuts, bolts, gaskets, supports etc. duly insulated on chilled water line as per requirement and specified and as per direction of Engineer-Incharge. 5.1 Butterfly Valves (PN - 16) 80 mm dia. 5.2 Balancing Valves (PN - 16) 80 mm dia 5.3 Y Shape Strainer (PN - 16) 80 mm dia 5.4 Supply and fixing of Zoloto Make forged Brass Ball valve o (screwed) with Hex nipple elbow (screwed) i/c providing and welding the same size socket on the MS pipe at terace complete as per site requirement and as per direction of Engineer incharge Rates not to be quoted here Supply, fixing, testing and commissioning of Heavy class mild steel black steel pipes confirming to IS: 1239 with all necessary fittings, Bend,reducer,Tee,Flanges,supports and PUF insulation having density 36Kg±2Kg/m³with polythene cover and then 26 gauge aluminium cladding etc. as required and as per direction of engineer-incharge. 25 mm dia 5.6 5.7 6 10 No. 10 No. 10 No. 10 mtrs 50 Sqm 340 Sqm 280 SS Pressure gauge 4"dial type with Ball valve 1/2"dia with reqd accessories etc as reqd. Thermometer dial type with reqd accessories etc as reqd. Providing, fixing, testing and commissioning of auto airvent in chilled water line in AHU room complete with all accessories settings etc. 10 mm (3/8") dia. G.I. Drain Piping Providing, fixing, testing and commissioning of G.I. drain piping with 19 mm thick nitrile rubber insulation complete with fittings like elbow,Tee,reducer,socket, supports as per specification and drawings 50 mm dia. 50mm dia 7 G.I Sheet Ducting(Rectangular) Providing, fixing, testing and commissioning of sheet metal ducting complete with supports, dampers etc. as per specifications etc as reqd. 22 Gauge 8 Insulation Providing and fixing of glass wool insulation 50mm thick having density 32Kg/m³ on ducts using resin bonded glass wool covered with checken wire mesh and finished with 26 Ga aluminium cladding etc as reqd. Rates not to be quoted here 5.5 No. 9 Dismentling of existing Fire Dampers and Supply & Fixing of New G.I Fire Dampers made out of 16Gauge G.I Sheet 150mm depth with fusible link etc as reqd and as per direction of engineerincharge. Sqm 15 No. 5 Sub-Total 10 Rebate Rebate,credit/buy-back of old existing AHUs complete with,fan,fan motor,cooling coil,filters & other connected accessories etc as reqd and as per direction of engineer-incharge. Total Rates not to be quoted here
© Copyright 2024 ExpyDoc