ICO2788 Icopal SA Bitumen Primer Information Sheet

PRODUCT INFORMATION SHEET
March 2014
Vs1
CI/SfB
Uniclass
World Reference
in Waterproofing
L681: P34
Issue 02
Icopal SA Bitumen Primer
Solutions and Compounds
Description
Properties
Icopal SA Bitumen Primer is a low viscosity, black, quick drying
bitumen priming solution consisting of high quality bitumen’s and
hydrocarbon solvents. The product is supplied in 4.5 kg tins.
Colour
Appearance
Flashpoint
Coverage Rate
Drying Time*
Container Size
Intended Use
Icopal SA Bitumen Primer is designed to penetrate and seal dusty
or porous substrates of masonry, concrete, cementitious screeds
or renders, existing bituminous or asphalt waterproofing, structural
steelwork and other metals, prior to the application of heatactivated self-adhesive bituminous membranes.
* depending on ambient conditions.
Compatibility
Icopal SA Bitumen Primer is compatible with most building
materials with which it is likely to come into contact with. However
spillage onto hydrocarbon based materials, such as bitumen
membranes and mastic asphalt, may cause some softening of
those surfaces if left unattended. It is not suitable for use in
combination with polystyrene or soft pvc products.
Surface Preparation
Ensure the substrate is structurally sound, free of surface laitance,
oils, grease, dirt, moss, lichen, and loose material.
The surface should be smooth and free from sharp projections and
loose debris, and any material which would hinder adhesion.
Typical Specification
Application
Substrates to be suitably prepared and primed with
Icopal SA Bitumen Primer, as supplied by Icopal Ltd, Barton Dock
Road, Stretford, Manchester, M32 0YL. Tel: 0161 865 4444. Fax:
0161 865 8433.
Icopal SA Primer is ready for use and should not be diluted. Using a
brush or roller apply Icopal SA Primer at a rate of 100-300 g/m²
depending on type and absorbency of substrate. Apply a thin coat
and avoid pooling. Primer to be dry to touch prior to application of
the self adhesive membrane. Icopal SA Primer should not be
applied to wet surfaces.
NBS Specification
Icopal SA Bitumen Primer is specified using
the following:
Clause: J41/320, J42/320
Product: Icopal SA Bitumen Primer
Manufacturer:
Manufacturer: Icopal Ltd. Barton Dock
Road, Stretford, Manchester, M32 0YL. Tel:
0161 865 4444.
Absorbent Substrates (eg bitumen, concrete, timber, etc)
Allowed if:
Substrate
Application Temp
> 0 °C
> 0 °C + frost warning
> -10 °C
Black/Brown
Liquid
- 20 °C
4 -- 10 m²/kg
5 to 30 mins
4.5 kg
Dry
Damp †
Yes
Yes
Yes
Yes
No
No
† Water film on the substrate is not allowed
Non-absorbent Substrates (eg metal, plastic, etc)
Allowed if:
Substrate
Application Temp
> 0 °C
> 0 °C + frost warning
> -10 °C
Icopal Limited
Dry
Wet
Yes
Yes
Yes
No
No
No
–1–
Ref: ICO2788
Barton Dock Road • Stretford • Manchester • M32 0YL • Tel: +44 (0)161 865 4444 • Fax: +44 (0)161 864 2616 • web: www.icopal.co.uk • email: [email protected]
PRODUCT INFORMATION SHEET
Icopal SA Bitumen Primer
Solutions and Compounds
Quality Assurance
Inhalation: Contains low volatility solvent. When used on roofs,
stand upwind of the work and avoid inhalation. Switch off all
working ventilation inlets prior to the use of the material; leave
covered until there is no odour of the solvent in the vicinity.
Indoors, use only in well ventilated areas. In the event of discomfort
as a result of inhalation, move person to fresh air. If discomfort
persists obtain medical attention.
Icopal SA Bitumen Primer is supplied under
a Quality Management System approved to
ISO 9001: 2000 by BSI Quality Assurance.
QMS: Q5556
Storage
Oral ingestion: With proper handling this should not occur.
The possibility can be minimized by not consuming food in the
working area and by washing hands thoroughly before eating,
drinking or smoking.
Icopal SA Bitumen Primer is supplied in 4.5 kg metal buckets.
Product must be stored under cover on a flat, level, and clean
surface away from sources of ignition, including pilot lights and
sparks. Keep containers tightly closed when not in use. In original
unopened containers the shelf life is 12 months.
Spillage: Spilt material should be mopped up immediately with an
inert absorbent material, such as sand or sawdust, and disposed of
in accordance with the regulations.
Health and Safety
Disposal of containers: Do not leave containers on site where
residue could be a hazard to children, animals or the environment.
Replace lids securely and remove any containers to a central
disposal point.
Please refer to the separate Health and Safety Data Sheet on
Icopal SA Bitumen Primer.
PPE should be worn.
Technical Services
Flammability: Flammable
Keep away from sources of ignition including pilot lights and
sparks. Take precautionary measures against static discharge.
Keep containers tightly closed when not in use.
Specialist advice and design guidance on all matters relating to
Icopal SA Bitumen Primer is freely available from our Technical
Department at the address below.
DO NOT SMOKE
Availability
If used in an enclosed space ensure thorough ventilation of
the area (using flame proof mechanical blowers if necessary)
to avoid any accumulation of vapour until the product has dried.
Item Code
3007163
Description
Icopal SA Bitumen Primer
Pack Size
4.5 kg
In case of fire: Use dry powder, carbon dioxide (CO2), or water mist.
Never use water jet as this may spread the fire.
Note: Electric motors, light/power switches and steel tools may
generate sparks sufficient to ignite the product or vapour, resulting
in an explosion and/or fire.
Skin Contact:
Contact Contains solvents that cause de-fatting of the skin
and, in extreme circumstances dermatitis.
Avoid contact by careful working and use of barrier creams or wear
gloves. Remove skin contamination immediately with a proprietary
cleaner and wash hands with soap and water.
Eye Contact:
Contact Avoid contact. Product could have an irritating effect.
In the event of accidental contact, wash eyes with clean water for
15 minutes and obtain medical attention.
NOTE: This information is given in good faith being based on the latest knowledge known to Icopal Limited. Whilst every effort has been made to ensure the
contents of the publication are current while going to press, customers are advised that products, techniques and Codes of Practice are under constant review
and liable to change without notice. Up to date information is available from our Technical Services Department on request.
Responsibility cannot be accepted for the application of products, and no claims can be considered, where the manufacturer’s instructions have not been
followed. The user should not assume; based on information provided in this sheet, that the product is suitable for any abnormal use.
All products are sold subject to our standard conditions of sale, available on request.
–2–
Ref: ICO2788
Icopal Limited
Barton Dock Road • Stretford • Manchester • M32 0YL • Tel: +44 (0)161 865 4444 • Fax: +44 (0)161 864 2616 • web: www.icopal.co.uk • email: [email protected]