PRODUCT INFORMATION SHEET March 2014 Vs1 CI/SfB Uniclass World Reference in Waterproofing L681: P34 Issue 02 Icopal SA Bitumen Primer Solutions and Compounds Description Properties Icopal SA Bitumen Primer is a low viscosity, black, quick drying bitumen priming solution consisting of high quality bitumen’s and hydrocarbon solvents. The product is supplied in 4.5 kg tins. Colour Appearance Flashpoint Coverage Rate Drying Time* Container Size Intended Use Icopal SA Bitumen Primer is designed to penetrate and seal dusty or porous substrates of masonry, concrete, cementitious screeds or renders, existing bituminous or asphalt waterproofing, structural steelwork and other metals, prior to the application of heatactivated self-adhesive bituminous membranes. * depending on ambient conditions. Compatibility Icopal SA Bitumen Primer is compatible with most building materials with which it is likely to come into contact with. However spillage onto hydrocarbon based materials, such as bitumen membranes and mastic asphalt, may cause some softening of those surfaces if left unattended. It is not suitable for use in combination with polystyrene or soft pvc products. Surface Preparation Ensure the substrate is structurally sound, free of surface laitance, oils, grease, dirt, moss, lichen, and loose material. The surface should be smooth and free from sharp projections and loose debris, and any material which would hinder adhesion. Typical Specification Application Substrates to be suitably prepared and primed with Icopal SA Bitumen Primer, as supplied by Icopal Ltd, Barton Dock Road, Stretford, Manchester, M32 0YL. Tel: 0161 865 4444. Fax: 0161 865 8433. Icopal SA Primer is ready for use and should not be diluted. Using a brush or roller apply Icopal SA Primer at a rate of 100-300 g/m² depending on type and absorbency of substrate. Apply a thin coat and avoid pooling. Primer to be dry to touch prior to application of the self adhesive membrane. Icopal SA Primer should not be applied to wet surfaces. NBS Specification Icopal SA Bitumen Primer is specified using the following: Clause: J41/320, J42/320 Product: Icopal SA Bitumen Primer Manufacturer: Manufacturer: Icopal Ltd. Barton Dock Road, Stretford, Manchester, M32 0YL. Tel: 0161 865 4444. Absorbent Substrates (eg bitumen, concrete, timber, etc) Allowed if: Substrate Application Temp > 0 °C > 0 °C + frost warning > -10 °C Black/Brown Liquid - 20 °C 4 -- 10 m²/kg 5 to 30 mins 4.5 kg Dry Damp † Yes Yes Yes Yes No No † Water film on the substrate is not allowed Non-absorbent Substrates (eg metal, plastic, etc) Allowed if: Substrate Application Temp > 0 °C > 0 °C + frost warning > -10 °C Icopal Limited Dry Wet Yes Yes Yes No No No –1– Ref: ICO2788 Barton Dock Road • Stretford • Manchester • M32 0YL • Tel: +44 (0)161 865 4444 • Fax: +44 (0)161 864 2616 • web: www.icopal.co.uk • email: [email protected] PRODUCT INFORMATION SHEET Icopal SA Bitumen Primer Solutions and Compounds Quality Assurance Inhalation: Contains low volatility solvent. When used on roofs, stand upwind of the work and avoid inhalation. Switch off all working ventilation inlets prior to the use of the material; leave covered until there is no odour of the solvent in the vicinity. Indoors, use only in well ventilated areas. In the event of discomfort as a result of inhalation, move person to fresh air. If discomfort persists obtain medical attention. Icopal SA Bitumen Primer is supplied under a Quality Management System approved to ISO 9001: 2000 by BSI Quality Assurance. QMS: Q5556 Storage Oral ingestion: With proper handling this should not occur. The possibility can be minimized by not consuming food in the working area and by washing hands thoroughly before eating, drinking or smoking. Icopal SA Bitumen Primer is supplied in 4.5 kg metal buckets. Product must be stored under cover on a flat, level, and clean surface away from sources of ignition, including pilot lights and sparks. Keep containers tightly closed when not in use. In original unopened containers the shelf life is 12 months. Spillage: Spilt material should be mopped up immediately with an inert absorbent material, such as sand or sawdust, and disposed of in accordance with the regulations. Health and Safety Disposal of containers: Do not leave containers on site where residue could be a hazard to children, animals or the environment. Replace lids securely and remove any containers to a central disposal point. Please refer to the separate Health and Safety Data Sheet on Icopal SA Bitumen Primer. PPE should be worn. Technical Services Flammability: Flammable Keep away from sources of ignition including pilot lights and sparks. Take precautionary measures against static discharge. Keep containers tightly closed when not in use. Specialist advice and design guidance on all matters relating to Icopal SA Bitumen Primer is freely available from our Technical Department at the address below. DO NOT SMOKE Availability If used in an enclosed space ensure thorough ventilation of the area (using flame proof mechanical blowers if necessary) to avoid any accumulation of vapour until the product has dried. Item Code 3007163 Description Icopal SA Bitumen Primer Pack Size 4.5 kg In case of fire: Use dry powder, carbon dioxide (CO2), or water mist. Never use water jet as this may spread the fire. Note: Electric motors, light/power switches and steel tools may generate sparks sufficient to ignite the product or vapour, resulting in an explosion and/or fire. Skin Contact: Contact Contains solvents that cause de-fatting of the skin and, in extreme circumstances dermatitis. Avoid contact by careful working and use of barrier creams or wear gloves. Remove skin contamination immediately with a proprietary cleaner and wash hands with soap and water. Eye Contact: Contact Avoid contact. Product could have an irritating effect. In the event of accidental contact, wash eyes with clean water for 15 minutes and obtain medical attention. NOTE: This information is given in good faith being based on the latest knowledge known to Icopal Limited. Whilst every effort has been made to ensure the contents of the publication are current while going to press, customers are advised that products, techniques and Codes of Practice are under constant review and liable to change without notice. Up to date information is available from our Technical Services Department on request. Responsibility cannot be accepted for the application of products, and no claims can be considered, where the manufacturer’s instructions have not been followed. The user should not assume; based on information provided in this sheet, that the product is suitable for any abnormal use. All products are sold subject to our standard conditions of sale, available on request. –2– Ref: ICO2788 Icopal Limited Barton Dock Road • Stretford • Manchester • M32 0YL • Tel: +44 (0)161 865 4444 • Fax: +44 (0)161 864 2616 • web: www.icopal.co.uk • email: [email protected]
© Copyright 2024 ExpyDoc