3/4/2014 Building Performance in the Commercial Building Realm Through the Ducts Presented by: - Matthew D. Todd. P.E. LEED AP CPMP BEAP – Neal Walsh, MBA BPC IN THE CML REALM THR0UGH THE DUCT Today’s Agenda: 1) Introduction 2) RES vs CML 3) Approaches to the CML BPC Market 4) CML Projects 5) Stories 6) Next Steps 1 3/4/2014 BPC IN THE CML REALM THR0UGH THE DUCT 1) Overview: Intro a. Why Consider the CML Market? i. The Population of CML Buildings - Under 10,000 sq.f.t Overall % with Packaged Equipment What kind of systems b. Building Performance Conference 2013 i. Refocus on overall Market Place for BPC c. Existing Level of Training i. Additional tools • 2 3/4/2014 BPC IN THE CML REALM THR0UGH THE DUCT 2) RES vs CML a. RES – 95% Leak to the published 25 - 40% (Or More!) b. Light CML Medium Pressure Ductwork Leaks too: • Class Level 142 • 30% Leakage c. Hi Pressure even has leakage…. • But not all of it does… – Not as extensive of sampling size – Data scatter is much broader – 15-20% 3 3/4/2014 BPC IN THE CML REALM THR0UGH THE DUCT 3) Approaches to the CML BPC Market a. Energy Consumption b. Air volume c. Building Pressurization Benefits from sealing air ducts 1. Enhanced Building Pressurization 2. Improved Indoor Air Quality •3. Lower Utility Bills 4 3/4/2014 IAQ Examples IAQ Examples "Engineers determined that the buildings’ ventilation systems were seeding mold throughout the structures." SMACNA & Duct Leakage • • SMACNA specifies the method for testing air ducts and establishes guidelines for allowable leakage levels in their HVAC Air Duct Leakage Test Manual They create 3 seal classes to specify which joints must be sealed • A = ≥4 inWG – seal all joints and wall penetrations • B = 3 inWG – seal all joints • C = ≤2 inWG – seal all transverse joints • • They recommend 6 leakage classes based on duct construction and seal class Each leakage class combined with the operating pressure can be used to determine a maximum leakage expressed as a % of the duct surface area Confidential - Do not copy, distribute or transmit without 5 3/4/2014 SMACNA & Duct Leakage • • • Formula for calculating maximum permissable leakage: Leakagemax = CL X P0.65 X SA Where • • • – Leakagemax = maximum leakage expressed in CFM at test pressure SA = duct surface area expressed in units of 100 sqft P = Test pressure expressed in units of inWG CL = leakage class specified by design engineer Operating Pressure (in WG) 0.5, 1, 2 3 4 Round 8 4 2 Rectangular 16 8 4 Air Ducts Leak 1. System leakage significantly increases building energy leakage(1) 2. A leaking VAV system uses 20%-35% more fan energy than a tight system(2) 3. A fan exhaust system with 20% leakage causes fan power to increase 95%(2) Source: (1) ASHRAE Handbook, Duct Design and (2) ASHRAE SPC 215P: MOT to Determine Leakage Airflows and Fractional Leakage of Operating Air Handling Systems Air Ducts Leak 1. Light Commercial duct leakage is typically 30% or more(1) 2. Leakage Classes >Cl = 200 are common(2) 3. On average, 10-20% of air provided by supply fans does not reach the occupied space(3) Sources: (1) Florida Solar Energy Center, California Energy Commission Studies) (2) Lawrence Berkeley Nat’l. Laboratory Studies) (3) Lawrence Berkeley Nat’l. Laboratory Studies) 6 3/4/2014 Annual Fan Operating Cost Cost of Leaking Ducts $16,000 $15,000 $14,000 $13,000 $12,000 $11,000 $10,000 $9,000 $8,000 +71% +53% +41% +17% Cl3 Cl6 Cl12 Cl24 Cl48 Duct Leakage Class Healthcare – University of Ottawa Heart Institute Canada’s largest cardio-vascular health center Issue: Lab exhaust leaks causing radioactive isotope migration Result: 94% reduction in leakage “The positive impact that Aerosealing the shaft had on system performance was clear and immediate.” Michele Emond, University of Ottawa Healthcare - Arzanah Medical Complex New LEED Gold 220,000 sqft medical complex Issue: Supply and return air duct leakage exceeded specifications Result: 94% reduction in leakage “Aeroseal proved safe for use even in a hospital. Aeroseal was so effective at eliminating leaks, That we decided to expand the project to include The building’s entire HVAC system.” Gus Heber Habtoor Leighton 7 3/4/2014 Healthcare - Nemours Children Hospital 630,000 sqft, 137 bed children’s hospital Issue: General exhaust leakage contributing to nocosomial infection rates Result: 85% reduction in leakage “After sealing the leaks with Aeroseal, all floors are getting the ventilation they need. As a side benefit, we were able to dramatically reduce the speed of the exhaust fan, which has resulted in substantial energy savings for the clinic.” Chuck Boynton Carrier Corp CV SUPPLY PAYBACK Annual Savings $40,000 $35,000 $30,000 AHU 4 x 40,000 cfm Occupancy 12hr/200 days Energy cost: 0.13 $/kW 1.00 $/therm Fresh air: 30% Initial leakage : 20% Final leakage : 4% HDD/CDD 5,300/1,400 Efficiency 10 EER/78% $25,000 $20,000 $15,000 Fan Energy Fan Motor $10,000 Heating Load Cooling Load $5,000 $- VAV SUPPLY PAYBACK Annual Savings $35,000 AHU 4 x 40,000 cfm Occupancy 12hr/200 days Energy cost: 0.13 $/kW 1.00 $/therm Fresh air: 30% VFD 50% hrs. @ 75% CFM $30,000 30% hrs. @ 50% CFM Initial leakage 20% $25,000 $20,000 Final leakage 4% HDD/CDD 5,300/1,400 Efficiency 10 EER/78% $15,000 $10,000 Fan Energy Fan Motor $5,000 Heating Load Cooling Load $- 8 3/4/2014 CENTRAL EXHAUST PAYBACK Annual Savings Exhaust 4 x 40,000 cfm fans Occupancy: 12 hrs. / 200 days Energy cost: 0.13 $/kW 1.00 $/therm $70,000 Initial leakage : 20% $60,000 Final leakage : 4% HDD/CDD 5,300/1,400 Efficiency 10 EER/78% $50,000 $40,000 $30,000 Fan Energy $20,000 $10,000 Heating Load Cooling Load $- BPC IN THE CML REALM THR0UGH THE DUCT 4) CML Projects – Renton School District • Lindberg H.S. Images • Food Service Building – Franklin Suites “ The tenants had horrible air flow prior to that because of the super leaky ducts. ENTEK sealed the lower floor system. They capped one run, repaired a couple of things and reduced leakage completely! We have not had a complaint there since, it totally worked.” – Jack McKinney, AIA Franklin Suite LLC – Elementary School – Video (5 Min) 9 3/4/2014 10 3/4/2014 11 3/4/2014 12 3/4/2014 BPC IN THE CML REALM THR0UGH THE DUCT 5) Simple BPC Stories – Ershigs …. – iQCU Van Mall Branch 13 3/4/2014 14 3/4/2014 15 3/4/2014 16 3/4/2014 BPC IN THE CML REALM THR0UGH THE DUCT 6) Next Steps – Get Educated • CI, Dr. Energy, Green Homes • DOE/ASHRAE/ACCA • RESNET/HERS/ BPI – Understand at the Fundamental How Buildings Work • It is not always just Metal Ducts that Needs to be sealed • More Chases, Plenums, Corridors, stairwells, atria BPC IN THE CML REALM THR0UGH THE DUCT 6) Next Steps (Continued) – Develop a Process – Educate your Staff – Align with the Right Partners/Products – Get into the Market 17
© Copyright 2024 ExpyDoc