Adjustable parameters – Other bodybuilder functions Introduction Introduction To limit this list of adjustable parameters, only parameters considered to be of use to bodybuilders are described. For full details of the current parameters for a specific vehicle, contact an authorised Scania workshop. The parameters are stored in the vehicle's various control units, and can be adjusted using SDP3 (Scania Diagnos & Programmer 3) and SDP3 for bodybuilders. This document is a comprehensive list. Which of these parameters and settings are available in a specific vehicle depends on how the vehicle is equipped and the vehicle specification. Apart from the adjustable parameters, there are also parameters which describe the physical specification of the vehicle in a SOPS file (Scania On-board Product Specification). This type of parameter may need to be updated when a conversion is carried out. Further information about SOPS is contained in the document Reprogramming control units under General information. 22:10-067 Issue 1 en-GB 1 (9) © Scania CV AB 2014, Sweden Adjustable parameters – Other bodybuilder functions Introduction SDP3 for bodybuilders SDP3 for bodybuilders enables bodybuilders to check and adapt the parameters described in this document. SDP3 for bodybuilders is a limited version of SDP3, which is used by Scania workshops. The tool is limited to only deal with parameters for bodybuilders. System designations BWE EMS SMS COO VIS ICL LAS Bodywork system Engine management system Suspension management system Coordinator Visibility system Instrument cluster Lock and alarm system 22:10-067 Issue 1 en-GB 2 (9) © Scania CV AB 2014, Sweden Adjustable parameters – Other bodybuilder functions Introduction Chassis conditions Vehicle production period Production site Södertälje Zwolle Angers São Bernardo do Campo Chassis serial number - Factory-fitted option packages Option Bodywork control unit BCI If required Bodywork cable harness from cab to frame Bodywork cable harness in frame Alternative With Variant code 5837A 7+7+7-pin 2m 8m 12 m 2411F 3023A 3023D 3023C Description of adjustable parameters Each parameter is identified through its parameter designation in the heading. Each parameter designation is concluded with the system to which the parameter is allocated, indicated in brackets. 22:10-067 Issue 1 en-GB 3 (9) © Scania CV AB 2014, Sweden Adjustable parameters – Other bodybuilder functions Other bodywork-related parameters Other bodywork-related parameters Selecting the EXT switch (BWE) Indicates which type of switch is used to enable remote control. • Without – There is no EXT switch. • 2 positions – Switch with 2 positions. • Spring-loaded – Spring-loaded switch. Basic setting: Spring-loaded. CAN communication with bodywork (BWE) With this parameter, you can determine whether the external CAN bus for communication with the bodywork should be used or not. More information on the CAN messages available can be found in the CAN bodywork interface document under Electrical system. • With – External CAN interface is activated. • Without – External CAN interface is deactivated. Basic setting: Without. 22:10-067 Issue 1 en-GB 4 (9) © Scania CV AB 2014, Sweden Adjustable parameters – Other bodybuilder functions Optional signals for bodywork Optional signals for bodywork Adaptation to bodywork gauges Gauges for oil pressure, coolant temperature, fuel level, engine load, pressure in service brake circuits 1 and 2, transmission oil temperature, retarder oil temperature and trailer weight. Here you have the option to set seven pairs of values to adapt the signal which the bodywork control unit can transmit to any external gauge. These values only apply to external analogue gauges e.g. an indicator in an operation unit on the frame. Each pair of values comprises an x value and a y value. These values must be adjusted so that they match the gauge on which the signal will be displayed. Use the x values to adjust the signal to the gauge to be used. For linear gauges, it is a good idea to have a relatively uniform distance between the x values. For non-linear gauges, the x values should follow the curve of the gauge, which should be provided in the data sheet for the gauge. If the operating range is limited, it is possible to place an extra point inside this range to obtain better resolution there. Use y values to adjust the signal so that the gauge gives a correct reading. If the duty cycle (duty cycle) is indicated in the data sheet for the gauge you can use these values, otherwise you must continue testing. Remember that all seven pairs of values must have a set value. In addition, these values must be in either a rising or falling sequence. 22:10-067 Issue 1 en-GB 5 (9) © Scania CV AB 2014, Sweden Adjustable parameters – Other bodybuilder functions Optional signals for bodywork Oil pressure gauge (BWE) Possible values: X (bar) 0–10 Y (%) 0-100 The following values are set at the factory: X (bar) 0 Y (%) 93 1.0 80 2.0 67 4.0 55 6.0 47 8.0 42 10 39 Duty cycle 110 86 120 89 Duty cycle Coolant temperature gauge (BWE) Possible values: X (°C) -40–150 Y (%) 0-100 The following values are set at the factory: X (°C) Y (%) 40 45 70 66 80 72 90 77 100 82 22:10-067 Issue 1 en-GB 6 (9) © Scania CV AB 2014, Sweden Adjustable parameters – Other bodybuilder functions Optional signals for bodywork Fuel level gauge (BWE) Possible values: X (%) Y (%) 0-100 0-100 The following values are set at the factory: X (%) Y (%) 0 93 5 86 10 80 25 66 50 51 75 43 100 39 Fuel level Duty cycle 75 43 100 39 Engine load Duty cycle Engine load gauge (BWE) Possible values: X (%) Y (%) 0–250 0-100 The following values are set at the factory: X (%) Y (%) 0 93 5 86 10 80 25 66 50 51 22:10-067 Issue 1 en-GB 7 (9) © Scania CV AB 2014, Sweden Adjustable parameters – Other bodybuilder functions Optional signals for bodywork Gauge for pressure in service brake circuit 1 (BWE) Possible values: X (bar) 0–20 Y (%) 0-100 The following values are set at the factory: X (bar) 0 Y (%) 93 1.0 80 2.0 69 4.0 55 6.0 47 8.0 42 10.0 39 Duty cycle Gauge for pressure in service brake circuit 2 (BWE) Possible values: X (bar) 0–20 Y (%) 0-100 The following values are set at the factory: X (bar) 0 Y (%) 93 1.0 80 2.0 69 4.0 55 6.0 47 8.0 42 10.0 39 Duty cycle 22:10-067 Issue 1 en-GB 8 (9) © Scania CV AB 2014, Sweden Adjustable parameters – Other bodybuilder functions Optional signals for bodywork Transmission oil temperature gauge (BWE) Possible values: X (°C) -40–150 Y (%) 0-100 The following values are set at the factory: X (°C) Y (%) 50 35 80 62 100 75 120 83 130 86 140 89 150 92 Duty cycle 150 92 Duty cycle Retarder oil temperature gauge (BWE) Possible values: X (°C) -40–200 Y (%) 0-100 The following values are set at the factory: X (°C) Y (%) 50 35 80 62 100 75 120 83 130 86 140 89 22:10-067 Issue 1 en-GB 9 (9) © Scania CV AB 2014, Sweden
© Copyright 2024 ExpyDoc