NEW! LIGHTING CONTROLS WATTSTOPPER LIGHTING INTEGRATOR PANELS WITH DIGITAL LIGHTING MANAGEMENT DLM SUPPORT LMCP SERIES DESCRIPTION The LMCP Series panel provides simple network-capable lighting control enabling the automation of lighting functions throughout an entire facility. The HDR relays in the panel can respond directly to inputs from Digital Lighting Management (DLM) switches, occupancy sensors, daylight sensors, and input modules. FEATURES • Standard single pole heavy duty relays UL and cUL listed for both lighting and plug loads • Availabe in interiors sized for 8,24, or 48 relays maximum • LMCT -100 handheld Configuration tool recommended for setup • Runs event-based schedule routines independently (does not require BAS or Segment Manager) • Supports astronomical, time- based, and photocell-based event types • Two free topology DLM Category 5e local networks for DLM sensors, switches, and LMIO series input modules • Additional power available for low voltage switiches or accessories • Qualifies for use in ARRA-funded projects LENC-08-S LMCP SPECIFICATIONS Input voltage 120/277 VAC 60 Hz, 120/347 VAC 60 Hz, 240 VAC 50 Hz Secondary Class 2 Power Supply LMCP48 Approvals Weight LMCP8 LMCP24 LMCP48 8 Relay Enclosure 24 Relay Enclosure 48 Relay Enclosure Warranty 11 30 Amps ballast @ 277V 20 Amps ballast @ 347V 20 Amps tungsten @ 120V 30 Amps resistive @ 347V 1.5 HP @ 120V 14,000 Amps with HDR Heavy Duty Relay 32 to 131°F (0 to 55°C) 5-95% RH noncondensing NEMA 1 Surface (LENCxxS) or Flush (LENCxxF) 13"W x 10.5"H x 4.25"D (33.02 x 26.67 x 10.79 cm) 14"W x 23.37"H x 4.25"D (35.56 x 59.36 x 10.79 cm) 14"W x 35.75"H x 4.25"D (35.56 x 90.81 x 10.79 cm) UL and cUL Listed (E207852) LIGHTING CONTROLS 24 VDC output, up to 250 mA across 2 RJ45 ports per local network Local Network Segments Free-topology DLM local network segments may include digital switches and sensors Category 5e cable, 150 ft. per DLM device, up to 1,000 ft. total per local network Segment Network Parameters WattStopper LM-MSTP wire Linear topology; 4000 ft. maximum per segment Network Connections Terminals for connection to DLM segment network (BACnet MS/TP) Communication Protocol BACnet MS/TP Accessory Power Available LMCP8 800 mA @ 24 VDC LMCP24 1000 mA @ 24 VDC LMCP48 1000 mA @ 24 VDC HDR Relays Coil voltage, 24 VDC, pulse ON and pulse OFF Individually replaceable Mechanically latched contacts Relay Contact Ratings SCCR (short circuit current rating) Operating Temperature Operating Humidity Enclosure Rating Enclosure Options Dimensions LMCP8 LMCP24 16 lb (7.3 kg) 30 lb (13.6 kg) 46 lb (20.9 kg) 20 lb (9.1 kg) 50 lb (22.7 kg) 66 lb (29.9 kg) 5 years DIMENSIONS MODEL WIDTH HEIGHT ENCLOSURE WIDTH HEIGHT DEPTH 8-relay Interior 13" (33 cm) 10.5" (26.7 cm) LENC8S 15.8" (40.1 cm) 16.6" (42.2 cm) 4.6" (11.7 cm) LENC8F 17.1" (43.4 cm) 18.5" (47 cm) 4.6" (11.7 cm) 24-relay Interior 14" (35.6 cm) 23.4" (59.4 cm) LENC24S 24" (61 cm) 32" (81.3 cm) 4.6" (11.7 cm) LENC24F 25.9" (65.8 cm) 33.4" (84.8 cm) 4.6" (11.7 cm) 48-relay Interior 14" (35.6 cm) 35.8" (90.8 cm) LENC48S 24" (61 cm) 44.5" (113 cm) 4.6" (11.7 cm) LENC48F 25.9" (65.8 cm) 45.9" (116.6 cm) 4.6" (11.7 cm) March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 613 NEW! LIGHTING CONTROLS WATTSTOPPER LIGHTING INTEGRATOR PANELS WITH DIGITAL LIGHTING MANAGEMENT SUPPORT LMCP SERIES WIRING LM10-301 Connection and Wiring Diagram P115/277 wiring (see installation instructions for additional voltages) Watertight J Bo x Local Network A or B Occupancy Sensor Sensor Hood 115V AC Supply Switch LMPO-200 Sensor 277V AC Supply LMIO-301 277 115 NEU GND 277 115 NEU LMRJ Cables GND Class 2 wiring #20 AWG up to 250' #18 AWG up to 1000' To LMCP DLM Panel Connection Diagram To Segment Manager or BAS (optional) Segment Network Emergency Relay Wiring (Fail-safe, bypassed operation) To additional LMCP Panels or DLM Local Networks (optional) LM-MSTP Wire Emergency Lighting Circuit (linear topology twisted pair dataline) Local Network A Switch Switch N.C. Contactor Normal Power Sense Line Voltage HDR Relay Local Network B Occupancy Sensor Typical of up to 48 loads 11 Line Load H N C LMCP Panel LMRJ Cables ORDERING INFORMATION INSTALLATION LIGHITING CONTROLS MODEL LMCP8 LMCP24 LMCP48 IR Window Panel Interior IR Window Power On/Of f BA T= Sensor Configuratio n Load Config (PnL) Daylighting Confi g Button Configuration Dimming Configuratio n Adjust Light Level LMCP48 115/277 48HD 24EM Home/ Main Menu Select Back 277 Example: LMCP48-115/277-48HD-24EM277 48 Relay capacity panel with 115/277 VAC, 48 HDR relays, 24 Emergency relays, 277VAC coil voltage *Order enclosure separately. Up Left Right/Next Down MODEL LENC LMCT-100 ACCESSORIES PAGE HDR Mechanically latching relay with 5-pin plug-in connector, pilot contacts, override switch 660 LMCT - 100 Digital Wireless Configuration tool 614 PANEL INTERIOR Network-capable lighting control panel with maximum of 8 relay capacity* Network-capable lighting control panel with maximum of 24 relay capacity* Network-capable lighting control panel with maximum of 48 relay capacity* VOLTAGE OPTIONS 115/277 With 115/277 VAC supply 115/347 With 115/347 VAC supply 240 With 240 VAC supply NUMBER OF HDR RELAYS INSTALLED Replace “XX” with number of HDR relays installed XXHD (max. of interior relay capacity) NUMBER OF EMERGENCY RELAYS INSTALLED Replace “XX” with number of UL924 fail-safe emergency relays installed XXEM (max. of 24 relays, not available for 8 relay capacity panels) EMERGENCY RELAY COIL VOLTAGE 115 VAC coil voltage 115 240 VAC coil voltage 240 277 VAC coil voltage 277 347 VAC coil voltage 347 888-397-5353 USA kele.com LENC ENCLOSURES Lighting panel enclosure ENCLOSURE TYPE / SIZE 08 8 relay capacity 24 24 relay capacity 48 48 relay capacity PANEL TYPE Flush mounted style F Surface mounted style S 24 S Example: LENC24S 24 relay surface mounted enclosure. Enclosure sold separately. WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014
© Copyright 2024 ExpyDoc