psf22u.QXD 12/3/01 12:34 pm Page 1 Infra Red Flame Detection The Onshore Choice S111/121 Solar Blind Flame Detectors Key Features • Completely solar-blind for use outdoors High sensitivity with exceptional interference rejection BASEEFA approved EEX ia IIC T5 Housing protection IP65 Integral stainless steel 316 mounting bracket The use of micropower electronics allows multiple detectors to operate on conventional 2 wire detection circuits Built in response indicator High immunity to smoke, dust and grime • From many years experience in the design and manufacture of Infra-Red Flame Detectors, we have invented and patented the single sensor infra-red flame detector with optical filtering, producing the S111 and S121 detectors for use outdoors in a wide range of applications. Specifically designed for use in the demanding environments of the onshore petro-chemical industry, the S111 and S121 detectors incorporate an abrasion resistant sapphire window in a protective housing to meet IP65. psf22u.QXD 12/3/01 12:35 pm Page 2 S111/S121 S111/121 Solar Blind Flame Detectors With their unique filter and sensing system, the S111 and S121 detectors can be used in locations where other types of flame detectors give false alarms due to external interference e.g. sunlight and arc welding. Operation in the infra-red spectrum around 4.4 microns ensures that the detector will not blinded by thick smoke and will be tolerant to dirty environments. Use in Hazardous Areas The S111 and S121 detectors meet the requirements of EN50-020 Part 7 and are BASEEFA certified EEx ia IIC T5. Other approvals include FM, CSA, VdS, SA and most marine bodies. As part of an intrinsically safe circuit, they are suitable for Zones 0,1 and 2, where Group IIC gases or lesser hazards are CONTINUOUSLY present in explosive concentrations. With their long range, tolerance to dirty environments and high immunity to external interference, the S111 and S121 detectors represent a major advance in the technology of hydrocarbon flame detection. S111 detector with milspec plug and socket connector Benefits . . . . No false alarms from welding, sunlight or high intensity lamps Low maintenance costs Quick response to carbon fires Long range performance Applications . . . . . . . S121 detector with 20mm gland entry and internal connections Oil Refineries Fuel Storage and transfer bays Gas pumping stations Military and commercial aircraft hangars Petrochemical works Gas turbine enclosures Printing presses and paperworks Note: For offshore applications, the S - 131 is recommended. Please refer to the technical information sheet PSF058. psf22u.QXD 12/3/01 12:35 pm Page 3 S111/121 Performance The detector is designed to respond to a minimum time of three seconds, this being the optimum signal processing time constant of the circuitry. Varying sizes of fire will be detected at given distances in the same time and the graph shows the typical ranges for the detection of the flames, for given areas of liquid fuels. Note: These results are based upon the fire reaching equilibrium rates of combustion in still atmosphere. Typical Response The S111 and S121 detectors, by virtue of their construction and rejection of spurious radiation, are suitable for use both indoors and outdoors in a wide range of applications. They will detect a 0.1m2 petrol fire a 20 m on the centre line within approximately 10 seconds. A 0.4m 2 fire is detected at 40m. Installation arrangements are specific for the environment and risk situation. Directional Sensitivity and Range The polar diagram shows that the maximum detector sensitivity lies on the detector central axis. The variation of relative ranges with angle of incidence up to the maximum is shown.A The range of the detector will vary with the type of fuels as indicated above. Centre line range against petrol flames. Relative range as function of angle of incidence. DETECTOR psf22u.QXD 12/3/01 12:35 pm Page 4 S111/S121 S200 PLUS Series Technical Information Mechanical Material: Impact resistant moulded plastic (light grey) Dimension mm: 160H x 80W x 60D (without bracket) Weight (including bracket): 1.7 Kg Gland Entry (S121): Metal Parts (external & internal): 1 x 20mm Bright Stainless Steel 316 to BS1449 Pt 2 316 S 161 Electrical Supply Voltage: Quiescent Current: Alarm Current: Connections: S111 S121 15.5 to 25.5V dc 100µA max. at 20V dc 60 mA max Milspec plug sealed into body Milspec mating socket with 2m of 4 core PVC insulated, braid screened PVC sheathed cable to DEF Std 61-12 Pts 4 One 4 way, 2.5 mm heavy duty terminal block Environmental Operating Temp Range: -30°C (-40°C with reduced range) to + 70°C Storage Temperature: -40°C to + 80°C Relative Humidity: 95% (100% intermittent) Enclosure to: Hazardous Area: IP65 Classification BASEEFA EEx ia IIC T5 Suitable for use in zones 0,1 and 2 where group IIC gasses or lesser hazards are present in explosive concentrations. UK approved by BASEEFA Certificate No. Ex 812333 Certificate Performance Range: Field of View Response Time: 0.1m2 petrol at 20m 0.4m petrol at 40m etc 85° min inclusive 2 secs min, 5-10 secs typical Mounting Bracket Weight (Kg): 1.1 Construction: Bright Stainless Steel 316 to BS1449 Pt 2 316 S 161 Axial Rotation: 360° Elevation 80° Fixing Details: M8 bolts (location template provided) The right is reserved to modify or withdraw any product or service without notice Technical Information Sheet PSF022U Issue 3 www.tycofire.com ©Thorn Security Ltd. 2000
© Copyright 2024 ExpyDoc