85037-543-08 IU114257 85037-543-08 Directions for use Use of the Flexel® Bag for LevMixer® | Magnetic Mixer from 50L to 1000L equipped with Easy drain valve (EZD) A.Introduction B. EZD valve opening and closing operations 1. Opening of the EZD valve 1.1Push the collar up to unlock EZD valve and Clip 1.2Push the EZD valve up to open drain Flexel® Bag for LevMixer® | Magnetic Mixer from 50L to 1000L can be equipped with one or two EZD valves positioned on the bottom of the mixing bag. One clip will be delivered with each mixing bag equipped with one or two EZD valves. Note: All EZD valves equipped on the mixing bag will be delivered in CLOSE position. The 2 EZD valves can be used for filling, sampling or draining operations. Note: the EZD valve could also be used for sampling. ! Warning: In order to maintain the integrity of the mixing bag, only 1 activation is allowed: 1 activation is defined by one opening and one closing. 1.3Pull collar down to lock EZD valve in OPEN position during the fluid transfer (filling, draining or sampling) 2. Closing of the EZD valve 2.1Push the collar up to unlock EZD valve in CLOSE position during the storage or mixing process ! Warning: The use of the EZD valve equipped on a mixing bag 50L requires specific operations (cf. part D) ! Warning: The use of the EZD valve when the Palletank® are jacketed requires operations (cf. part E) ! Warning: The EZD valve is not compatible with the OLD version of Palletank manufactured with angular bottom bin. DInstructions for use for Flexel® Bag for LevMixer® | Magnetic Mixer from 50L using jacketed and non-jacketed Palletank® 2.2Pull the EZD valve down to close drain ! Warning: Do not close the EZD valve by pulling the tube. Pulling the tube might damage the connection (leakage). 1. Open the EZD valve prior bag installation –P osition the clip under the EZD valve (cf. C.2) –U se the clip to open the EZD valve following B-1 instructions. 2. For the 50L, insert the drive unit prior bag installation 3.Install the bag into the Palletank® According to the mixing technology used, please refer to the relevant manual: – Flexel® for Magnetic Mixer 50L | 100L | 200L | 400L | 650L | 1000L (Ref. 85032-537-50) – Flexel® Palletank® for LevMixer® 50L | 100L | 200L | 400L | 650L | 1000L (Ref. 85037-541-12) 4. Start bag filling 5.After bag filling close the EZD valve following B-2 instructions 6.Repeat opening and closing operations on the second EZD valve to drain the bag ! Warning: Do not remove the drive unit until the bag is fully emptied 2.3Pull the collar down to lock E.Instructions for use for Flexel® Bag for LevMixer® | Magnetic Mixer from 100L to 1000L using jacketed Palletank® 1. Open the EZD valve prior bag installation –P osition the clip under the EZD valve (cf. C.2) –U se the clip to open the EZD valve following B-1 instructions. 2. Install the bag into the Palletank® According to the mixing technology used, please refer to the relevant manual: – Flexel® for Magnetic Mixer 50L | 100 L | 200 L | 400 L | 650L | 1000L (Ref. 85032-537-50) – Flexel® Palletank® for LevMixer® 50L | 100L | 200L | 400L | 650L | 1000L (Ref. 85037-541-12) 3. Start bag filling 4.After bag filling close the EZD valve following B-2 instructions 5.Repeat opening and closing operations on the second EZD valve to drain the bag C.Instructions for use for Flexel® Bag for LevMixer® | Magnetic Mixer from 100L to 1000L using non-jacketed Palletank® 1. Install the bag into the Palletank® According to the mixing technology used, please refer to the relevant manual: – Flexel® for Magnetic Mixer 50L | 100 L | 200 L | 400 L | 650L | 1000L (Ref. 85032-537-50) – Flexel® Palletank® for LevMixer® 50L | 100L | 200L | 400L | 650 L | 1000 L (Ref. 85037-541-12) 2. Open the EZD valve prior bag filling – Position the clip under the EZD valve as showed below –U se the clip to open the EZD valve following B-1 instructions. 3. Start bag filling 4.After bag filling close the EZD valve following B-2 instructions 5.Repeat opening and closing operations on the second EZD valve to drain the bag Sartorius Stedim Biotech GmbH August-Spindler-Strasse 11 37079 Goettingen, Germany Phone +49.551.308.0 Fax +49.551.308.3289 www.sartorius-stedim.com Specifications subject to change without notice. Printed and copyrighted by Sartorius Stedim Biotech GmbH. | W Publication No.: S--6030-e131101 Ver. 11 | 2013
© Copyright 2024 ExpyDoc