CORE BUILD-UP TECHNIQUE*

CORE BUILD-UP TECHNIQUE*
15
1. Clean all surfaces
that will receive
the core material.
2.
Apply UNI-ETCH to the tooth
structure and post and etch for
15 seconds. Rinse thoroughly
with water. Remove excess water.
10
10-15
3. Apply 2 coats of ONE-STEP/
ONE-STEP PLUS, agitate
10-15 seconds.
1
4. Air dry and light cure for
10 seconds.
40
2
OR
7 min.
WAIT
5. Prepare the Dual-Syringe
Dispenser for CORE-FLO DC.
6. Express CORE-FLO DC
onto the preparation and
around the post.
7.
8. Continue with final
preparation for the
impression.
Remove excess material and
light cure for 40 seconds.
OPTIONAL: wait 7 minutes
for self cure.
* Refer to Instructions for complete details.
Bisco
DualCured
Flowable Core Build-Up Composite
%
Phone
BISCO, INC.
1100 W. Irving Park Road
Schaumburg, IL 60193
U.S.A.
847-534-6000
1-800-247-3368
www.bisco.com
INST-077R3
Rev. 6/14
Manufacturer
2
NATURAL / A1 - OPAQUE WHITE INTRO KIT
REF A-2311K
1 Dual-Syringe CORE-FLO DC Shade: NATURAL / A1 (8g),
1 Dual-Syringe CORE-FLO DC Shade: OPAQUE WHITE (8g),
1 Syringe UNI-ETCH® w/BAC (5g), 1 Bottle ONE-STEP® (2ml),
Accessories, Instructions/MSDS Single
Use
Single Use
Accessories
Accessories
Corrosive
For Dental
Use Only
Flammable
Irritant
Caution
Consult
Instructions
For Use
Recommended
Storage Temp.
Keep
Away From
Sunlight
POST CEMENTATION AND CORE
BUILD-UP TECHNIQUE*
15
10
1
2
1. Apply UNI-ETCH to the canal
and etch for 15 seconds.
Rinse thoroughly with water.
2. Blot the canal with a large
paper point to remove
excess moisture.
3. Apply 2 coats of ONE-STEP/
ONE-STEP PLUS. Blot excess
from canal with paper points
until paper point returns dry from
the canal.
10
5. Determine the post length
according to the manufacturer’s
instructions.
5-10
6. Coat the post with One-Step/
One Step Plus. Air dry and
light cure for 10 seconds.
4. Air dry adhesive to evaporate solvent. Light cure for
10 seconds.
1
2
7. Prepare the Dual-Syringe
Dispenser for CORE-FLO DC.
8. Express CORE-FLO DC
into the canal.
40
OR
7 min.
WAIT
9. Seat the post, maintaining
firm pressure for 5-10 seconds.
10.Continue to express
11.Remove excess material and
CORE-FLO DC around the light cure for 40 seconds.
post to bui­­­ld-up the core.
OPTIONAL: wait 7 minutes
for self cure.
12.Continue with final
preparation for the
impression.
* Refer to Instructions for complete details.