VGRCB-13C75 / VGFCB-13C75 The VGRCB-13C75 provides 13 coaxial contacts for signals up to 1Ghz. All cable connections to the VGR/VGFCB-13C75 are RG-179. Two precision alignment pins per block ensure proper alignment. Two shoulder mounting screws per VGR block allow the block to float in the receiver. Blocks sold separately. Contacts sold with cables only. Application Notes When designing solutions using the VGR/VGFCB-13C75blocks, keep in mind the “system” losses of the solution you are attempting to achieve. The band pass of the contacts less cabling of the VGR/VGFCB-13C75 solution is approximately1Ghz. The cable used with the VGR/VGFCB-13C75 contact is RG-179, which has a moderate loss rate at frequencies above 1Ghz. Typical loss @ 1Ghz is approximately .43dBper foot. When using the VGRXT extraction tool, first remove the Lexan cover from the VGR contact block. Coax Contact Pair Specifications Voltage Current Contact Resistance Impedance VSWR Crosstalk Bandwidth Durability Insertion Loss Ordering Information: Receiver Module: 36” Receiver Coax Cable Assy. Accessories Receiver Coax Extraction Tool 500 VDC .5 Amps 6mΩ 75Ω 1.10:1 @ 1Ghz Down 70db @ 1Ghz 1.2Ghz 20,000 Cycles .038db @ 1Ghz VGRCB-13C75 CR-CA75RG179-36 VGRXT Fixture Module: 36” Fixture Coax Cable Assy. VGFCB-13C75 CF-CA75RG179-36 Fixture Coax Extraction Tool VGFXT Contact ECT: USA +1-518-877-3753, Hungary +36-92-815-530, Singapore +65-6293-8966, China +86-2372-0477 Email us at [email protected] Visit ECT Online at www.ectinfo.com/fsg