Unique Features Applications ~~ Efficiency up to 99.8% ~~ Green building ~~ Small footprint and light weight – fits through a 36’’ doorway ~~ Industrial, institutional, residential buildings ~~ No heat exchanger maintenance required ~~ Thermal shock proof ~~ CPVC vent acceptable ~~ Air force, military base ~~ Recreational buildings ~~ Educational facilities ~~ Greenhouses ~~ Super low NOx: exceeds all North America regulation requirements ~~ Hotels and resorts ~~ CO can be adjusted to 0ppm ~~ Health care ~~ 10-sensor input touch screen controller BacNet, Modbus, LonWorks configurations available ~~ Food processing ~~ Industrial laundry ~~ Waste water treatment ~~ Anareobic digestors ~~ Car and truck washes 75.39 Gasmaster Commercial Line-up 75.39 GMI-12M 12,000,000 BTU/H GMI-8M 8,000,000 BTU/H 35.50 40.22 54.00 35.50 57.53 40.22 54.00 Input Output DRAWN DEBUR AND BREAK SHARP EDGES MATERIAL: FINISH: Boiler efficiency @ full load Fuel BTU/H 01/10/14 DE CHK'D APPV'D UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES MFG SURFACE FINISH: TOLERANCES: Q.A LINEAR: ANGULAR: NAME DRAWN DATE SIGNATURE DE WEIGHT: 01/10/14 Electrical rating MFG Q.A Shipping weight 1 TITLE: V/PH/Hz/A CHK'D APPV'D Heating surface % Ft2 MATERIAL: DWG NO. Lbs WEIGHT: SCALE:1:15 REVISION NEW GMI-4M 4,000,000 BTU/H 3,000,000 BTU/H DATE SIGNATURE NAME GASMASTER NX-3000 DO NOT SCALE DRAWING 57.53 DEBUR AND BREAK SHARP EDGES FINISH: TITLE: 2,880,000 DO NOT SCALE DRAWING DWG NO. SCALE:1:15 REVISION 96 NEW GMI3M-REV1 Natural gas A4 SHEET 1 OF 1 208-230/460/575/3/60/12 GMI3M-REV1 562A4 SHEET 1 OF 1 1487 Supply/return connections Lbs 4 - Stainless steel flange, ANSI 150 Water content USG 13.5 Gas connection Inches 2 NPTF Gas inlet pressure Inches WC 8 to 14 Flue connection Inches 10 O.D. Flue duct material CPVC Maximum working pressure psig 160 Maximum working temperature Degrees F 210 Minimum inlet water temperature Degrees F Any temperature above freezing point Minimum flow rate USG/min 60 (For Δt = 100 0F) Minimum service clearance Inches Top 24, front 362, back 24, floor 0 Minimum clearances to combustibles Inches Top 40, front 40, back 24, left side 24, burner side 24, floor non-combustible 1 2 GMI-2M/ML 2,000,000 BTU/H GMI-1.5M/ML 1,500,000 BTU/H GMI-1M/ML 1,000,000 BTU/H Dry weight of unit., Clearance from front of the burner. Visit our website to learn more www.gasmaster.ca GMI-800M/ML 800,000 BTU/H © Gasmaster 2014 | GASMASTER NX-3000 UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES SURFACE FINISH: TOLERANCES: LINEAR: ANGULAR:
© Copyright 2024 ExpyDoc