SCC Inc. Technical Instructions Document No. TS-2000 July 18, 2014 TS Series TS-MS… Master Panels for Boiler Management, Lead/Lag, and Building Management System Interface Description A TS-MS… Series Master Lead/Lag Panel sequences and controls up to four boilers equipped with TS... communication kits (see Technical Document TS-1000 or TS1050) or TS… complete combustion control enclosures (see Technical Document TS-4000). A master panel controls hot water or steam boilers with Siemens LMV series linkageless control systems. Each panel includes a 7.5” or 10” touchscreen with a programmable logic controller. Flexible communication interface options to the building management system (BMS) provide streamlined data collection, monitoring and controls. Additional options include pump controls and temperature measurement on steam boilers. SCC Inc. Technical Instructions Document No. TS-2000 Features TS Series • • • • • • • • • • • • • • • • • • Manages the operation of individual boilers with Siemens LMV… controllers Boiler lead/lag with automatic boiler rotation Parallel or sequential modulation Remote setpoint adjustment via BMS Outside air reset (hydronic boilers) Pressure or temperature based warm standby Cycling pump control outputs for hydronic boilers Return valve modulating output Analog input with label, span and type (0-10V, 2-10V, 020mA or 4-20mA) field-configured Pt1000 RTD temperature inputs for supply and return water temperature and outside air reset for hydronic boilers (optional inputs for steam boilers) Metric or Standard units display Graphics for individual boiler overview screens automatically configure based on local touchscreen selections Individual boiler alarms and status Clear English text for alarms Alarms logging, history, and trending Ethernet communication Standard Modbus TCP/IP BMS communication Additional BMS communication options available Application TS-MS Lead/Lag Systems are suited for hydronic boilers, steam boilers and other applications utilizing LMV3 or LMV5 linkageless control systems. Components All TS-MS… Master Panels include the following components: • 7.5” or 10” touchscreen • Power supply and branch circuit protection • Programmable Logic Controller (PLC) • Analog and digital inputs and outputs • Interconnect terminals for field wiring Page 2 SCC Inc. TS Series Technical Instructions Document No. TS-2000 Product Part Numbers For Master Lead/Lag Panel part number identification. TS - MS 1 0 S - S X X Touchscreen Master Lead/Lag Enclosure 1 = NEMA 1 / NEMA 4X Standard 2 = NEMA 12 Touchscreen Size 7 = 7.5" touchscreen 0 = 10" touchscreen BMS Communication S = Standard, Modbus TCP/IP (read/write) B = BACnet IP, BACnet MS/TP, Modbus RTU, or Johnson Metasys N2 L = LONWORKS Application S = Steam with touchscreen at each boiler H = Hot water with touchscreen at each boiler R = Serial steam without touchscreen at each boiler W = Serial hot water without touchscreen at each boiler U= Universal steam or hot water, with or without touchscreen at each boiler Temperature Measurement for Steam Boilers Y = 4 Platinum 1000 Ohm RTD Inputs X = Not applicable Pump Controls Y = Pump controls, one per boiler (4 dry contact relay outputs) X = Not applicable SCC Inc. Page 3 Technical Instructions Document No. TS-2000 TS Series Specifications Physical characteristics Operating environment 7.5” Touchscreen 10” Touchscreen Main power 120 VAC 120 VAC Touchscreen power 24 VDC 24 VDC Power consumption ≤ 6.8 W ≤ 17 W Dry contacts 2 Amps 2 Amps 32 to 122 °F [0 to 50 °C] 32 to 131 °F [0 to 55 °C] Operating temperature Humidity Page 4 Max. 80% with no condensation Max. 85% with no condensation NEMA rating (Standard) 4X (indoor use only) 4X (indoor use only) NEMA rating (Optional) NEMA 12 NEMA 12 SCC Inc. TS Series Technical Instructions Document No. TS-2000 Field Connections SCC Inc. Page 5 Technical Instructions Document No. TS-2000 TS Series Field Connections (continued) Page 6 SCC Inc. TS Series Technical Instructions Document No. TS-2000 Field Connections (continued) SCC Inc. Page 7 Technical Instructions Document No. TS-2000 TS Series Field Connections (continued) Page 8 SCC Inc. TS Series Technical Instructions Document No. TS-2000 Field Connections (continued) SCC Inc. Page 9 Technical Instructions Document No. TS-2000 TS Series BMS Communications Connections Standard (Modbus TCP/IP (read/write)) BACnet IP, BACnet MS/TP, Modbus RTU, or Johnson Metasys N2 LONWORKS Note: For all RS-485 connections, use Belden cable 3106A (multi-conductor cable with twisted pair, EIA Industrial RS-485 PLTC/COM) or equivalent. Table 1: Belden Cable 3106A Wire Color Designation Electrical Diagram Belden Cable 3106A Red (RS485+) Orange (RS485+) Black (RS485-) White (RS485-) White (SG) Blue (SG) Page 10 SCC Inc. TS Series Technical Instructions Document No. TS-2000 Enclosure Parts Description 2 1 4 6 5 11 12 7 8 10 9 13 14 3 15 16 Front 123456789101112131415161718- SCC Inc. 17 18 Back Pan 24 VDC PLC normal indicator light Main 120 VAC lockable disconnect handle 7.5” or 10” touchscreen 5-port Ethernet switch (provided only if there are touchscreen kits at each boiler) 24 VDC connecting terminals 24 VDC power supply Circuit breaker 120 VAC power terminals 120 VAC main disconnect with UL lock Grounding lugs BMS interface module (provided only for communications other than Modbus TCP/IP) Programmable Logic Controller (PLC) Analog input module RTD input module (always provided for hot water boilers; only provided if RTD option is selected for steam boilers) Pump control output terminals (provided only if pump controls option is selected) 24 VDC pump monitor digital input terminals (provided only if pump controls option is selected) Analog input terminals (4-20 mA or 0-10 VDC) 1000 Ohm Platinum RTD input terminals (always provided for hot water boilers; only provided if RTD option is selected for steam boilers) Page 11 Technical Instructions Document No. TS-2000 TS Series Enclosure Dimensions Dimensions in inches; millimeters in brackets Back Side (NEMA 1/NEMA 4X) Side (NEMA 12 with cover) Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners. © 2009 SCC Inc. SCC Inc. Your feedback is important to us. If you have Document No. TS-2000 1250 Lunt Avenue comments about this document, please send them Country of Origin: US Elk Grove Village, IL 60007 to [email protected] Page 12 U.S.A.
© Copyright 2024 ExpyDoc