...a step into a digital world 141016 • 02155 A star is born! GMM, galvanic isolated multimedia outlets Class A RF screening Double isolated ports Low insertion loss Small depth, only 26 mm 8 10 13 15 17 21 8 10 13 15 17 21 dB dB dB dB dB dB dB dB dB dB dB dB All three ports in the new innovative GMM multimedia outlet have double galvanic isolation. This solution not only physically separates the in-home network from the distribution network, it also physically separates the in-home wiring. No dangerous high voltages can cause injury or damage connected equipment. These safety features also prevent hum in your network and protect against the risk of fire. The class A, RF-screened housing ensures that ingress noise cannot affect the network and its small depth makes installation easy in standard back boxes. www.macab.com Macab GMM Triple galvanic isolation on all ports Prevents hum Class A screening efficiency Protects against electric shocks Low insertion loss Fits standard back boxes (26 mm) Protects against the risk of fire The Macab GMM series is a new innovative side by side. The 3-port galvanic isolation series of high-quality wall outlets, specially also increases the network’s signal quality designed for improved safety by reducing disturbances in cable TV networks. One of caused by hum. As an option, the key features is the 3-port the outlets can be supplied physical galvanic isolation that with a new series of halogen- in an effective way will protect free frames and covers, in the household members for two different shades of white. electric shocks and fire. The Applications outlets are the first of their kind, combining The GMM multimedia outlet fulfils the 3-port galvanic isolation with extremely requirements stipulated by the major cable-TV compact design, allowing the use of standard operators in Europe. The outlet is available with back boxes. The construction of the outlets is different attenuations for different applications, another key feature and the innovative design such as star or cascade configured networks. makes it easy to orientate and mount outlets Screening: The GMM series of outlets fulfil class A requirements, according to DIN EN 50083-2/A1. This provides a high level of security regarding the egress or ingress of disturbing frequencies. Phone: +46 410 36 36 10 • Fax: +46 410 36 36 01 2 www.macab.com ...a step into a digital world Unique Features 26 mm STANDARD DEPTH The GMM series of outlets has the same dimensions as standard outlets and fits into standard back boxes. EASY INSTALLATION: SPECIAL PROFILE Locks into the next outlet When designing the outlets we took into account their use in combinations frames, designing them for easy and fast fixing, both horizontally and vertically. All Macab outlets have a special profile, making them easier to install in combination frames. COMBINATION FRAMES: GALVANIC ISOLATORS Stop dangerous high voltages and prevent hum GALVANIC ISOLATORS: The GMM series of outlets has three built-in double galvanic isolators, which isolate both the inner and outer conductors (patent pending). These isolators, in each port, provides a unique level of isolation and maximum safety for users. Each port is totally isolated from the other ports and from other outlets, wich means that no current can flow from one port to another. The design also provides an effective solution to hum problems. Phone: +46 410 36 36 10 • Fax: +46 410 36 36 01 3 www.macab.com No halogen, frames and covers As an option, the outlets can be supplied with a new series of halogen-free frames and covers in two different shades of white. Frames and covers can also be customized. Part no 321 11 85 321 11 87 321 11 84 321 11 86 E no 60 758 17 60 758 65 60 758 16 60 758 64 Description Frame, Signal white RAL 9003 LSNH Frame, Pure white RAL 9010 LSNH Cover, Signal white RAL 9003 LSNH Cover, Pure white RAL 9010 LSNH TECHNICAL SPECIFICATIONS OUTLETS Type GMM-8T GMM-10 GMM-13 GMM-15 GMM-17 GMM-21 Part no E no Frequency range Insertion loss In-data In-TV/In-FM 321 13 80 60 758 18 321 13 81 60 758 19 321 13 82 321 13 85 60758 20 60 758 58 5–1000 MHz 321 13 83 60 758 21 321 13 84 60 758 22 8.5 ±1 10.5 ±1 15.0 ±1 17.5 ±1 21 ±1 15.5 ±1 15 ±1 2.5 18.0 ±1 17.5 ±1 2.0 22.0 ±1 21.5 ±1 2.0 min 27.5 min 35.5* min 31.0 min 39.0* In-out Return loss In, out In, out Data TV FM Isolation TV-FM Data-TV Data-FM TV, FM, Data-out MHz 13–1000 MHz 5–65 MHz 85–100 MHz 100–1000 MHz 5–1000 MHz dB dB dB dB dB 5–13 MHz 13–1000 MHz 13–65 MHz 85–1000 MHz 85–1000 MHz 85–1000 MHz dB dB dB dB dB dB min 18 (out), 10 (in) min 18 14, min >10 14 min >10 14 min >10 10 85–1000 MHz 5–65 MHz 85–1000 MHz 5–40 MHz 40–862 MHz dB dB dB dB dB min 10 min 40 min 20 min 23.5 min 25.0 min 31.5* min 33.0* Galvanic isolation Inner conductor in-out Outer conductor in-out Screening Impedance Connectors TV FM Data Dimension 13.5 ±1 min 40 9.0 ±1 8.5 ±1 - – – 11.0 ±1 10.5 ±1 4.2 min 20.5 min 28.5* 14.0 ±1 13.5 ±1 3.0 mA mA – ohm <8.5, 230 V AC, 50/60 Hz, <0.7, 2120 V DC for 1 min <8.5, 230 V AC, 50/60 Hz, <0.7, 2120 V DC for 1 min Class A 75 – – – mm IEC-male IEC-female F-female 70x68x26 *F>40 MHz, –1,5 dB/oct EMS ISO 9001 Environmental Management Standard 14001 Quality Management System Macab have since many years worked with the implementation of an environmental management system. We received the certification 2008 and we are audited annually by an independent ISO 14001 registrar. The ISO 14001 EMS standard is a voluntary international standard for effectively manage the impact on the environment. Since 2008, Macab is one of few companies in the antenna business, achieving the 9001 quality management standard. The certification proves that we are working diligently to establish quality and performance objectives. The overall aim is to achieve customer satisfaction through consistent products and services. GRG-Macab AS Lierstranda 82 NO-3400 Lierstranda, Norway Tlf: +47 32 22 99 90 Fax: +47 32 22 99 91 [email protected] Macab AB (HEAD OFFICE) Post: Box 3 SE-231 21 Trelleborg, Sweden Besök: Vannhögsgatan 7, SE-231 66 Trelleborg Tel: +46 (0) 410 36 36 10 Fax: +46 (0) 410 36 36 01 [email protected] Max Nordic A/S Friis Hansensvej 2 DK-7100 Vejle, Denmark Telefon: +45 31 68 20 10 [email protected] www.macab.com
© Copyright 2025 ExpyDoc