...a step into a digital world
141016 • 02155
A star is born!
GMM, galvanic isolated multimedia outlets
Class A RF
screening
Double
isolated
ports
Low
insertion
loss
Small depth,
only 26 mm
8
10
13
15
17
21
8
10
13
15
17
21
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
All three ports in the new innovative GMM multimedia outlet have double galvanic
isolation. This solution not only physically separates the in-home network from the
distribution network, it also physically separates the in-home wiring. No dangerous high voltages can cause injury or damage connected equipment. These safety features also prevent hum in your network and protect against the risk of fire.
The class A, RF-screened housing ensures that ingress noise cannot affect the
network and its small depth makes installation easy in standard back boxes.
www.macab.com
Macab GMM
Triple galvanic isolation on all ports
Prevents hum
Class A screening efficiency
Protects against electric shocks
Low insertion loss
Fits standard back boxes (26 mm)
Protects against the risk of fire
The Macab GMM series is a new innovative
side by side. The 3-port galvanic isolation
series of high-quality wall outlets, specially
also increases the network’s signal quality
designed for improved safety
by
reducing
disturbances
in cable TV networks. One of
caused by hum. As an option,
the key features is the 3-port
the outlets can be supplied
physical galvanic isolation that
with a new series of halogen-
in an effective way will protect
free frames and covers, in
the household members for
two different shades of white.
electric shocks and fire. The
Applications
outlets are the first of their kind, combining
The GMM multimedia outlet fulfils the
3-port galvanic isolation with extremely
requirements stipulated by the major cable-TV
compact design, allowing the use of standard
operators in Europe. The outlet is available with
back boxes. The construction of the outlets is
different attenuations for different applications,
another key feature and the innovative design
such as star or cascade configured networks.
makes it easy to orientate and mount outlets
Screening: The GMM series of outlets
fulfil class A requirements, according
to DIN EN 50083-2/A1. This provides
a high level of security regarding
the egress or ingress of disturbing
frequencies.
Phone: +46 410 36 36 10 • Fax: +46 410 36 36 01
2
www.macab.com
...a step into a digital world
Unique Features
26 mm
STANDARD DEPTH
The GMM series of outlets
has the same dimensions as standard outlets
and fits into standard back boxes.
EASY INSTALLATION:
SPECIAL PROFILE
Locks into the next outlet
When designing the
outlets we took into account their use in
combinations frames, designing them for easy
and fast fixing, both horizontally and vertically.
All Macab outlets have a special profile, making
them easier to install in combination frames.
COMBINATION FRAMES:
GALVANIC ISOLATORS
Stop dangerous high voltages and prevent hum
GALVANIC ISOLATORS: The GMM series of outlets has three built-in double
galvanic isolators, which isolate both the inner and outer conductors
(patent pending). These isolators, in each port, provides a unique
level of isolation and maximum safety for users. Each port is totally
isolated from the other ports and from other outlets, wich means that
no current can flow from one port to another. The design also provides
an effective solution to hum problems.
Phone: +46 410 36 36 10 • Fax: +46 410 36 36 01
3
www.macab.com
No halogen, frames and covers
As an option, the outlets can be supplied with a new
series of halogen-free frames and covers in two
different shades of white. Frames and covers can also
be customized.
Part no
321 11 85
321 11 87
321 11 84
321 11 86
E no
60 758 17
60 758 65
60 758 16
60 758 64
Description
Frame, Signal white RAL 9003 LSNH
Frame, Pure white RAL 9010 LSNH
Cover, Signal white RAL 9003 LSNH
Cover, Pure white RAL 9010 LSNH
TECHNICAL SPECIFICATIONS OUTLETS
Type
GMM-8T
GMM-10
GMM-13
GMM-15
GMM-17
GMM-21
Part no
E no
Frequency range
Insertion loss
In-data
In-TV/In-FM
321 13 80
60 758 18
321 13 81
60 758 19
321 13 82
321 13 85
60758 20
60 758 58
5–1000 MHz
321 13 83
60 758 21
321 13 84
60 758 22
8.5 ±1
10.5 ±1
15.0 ±1
17.5 ±1
21 ±1
15.5 ±1
15 ±1
2.5
18.0 ±1
17.5 ±1
2.0
22.0 ±1
21.5 ±1
2.0
min 27.5
min 35.5*
min 31.0
min 39.0*
In-out
Return loss
In, out
In, out
Data
TV
FM
Isolation
TV-FM
Data-TV
Data-FM
TV, FM, Data-out
MHz
13–1000 MHz
5–65 MHz
85–100 MHz
100–1000 MHz
5–1000 MHz
dB
dB
dB
dB
dB
5–13 MHz
13–1000 MHz
13–65 MHz
85–1000 MHz
85–1000 MHz
85–1000 MHz
dB
dB
dB
dB
dB
dB
min 18 (out), 10 (in)
min 18
14, min >10
14 min >10
14 min >10
10
85–1000 MHz
5–65 MHz
85–1000 MHz
5–40 MHz
40–862 MHz
dB
dB
dB
dB
dB
min 10
min 40
min 20
min 23.5
min 25.0
min 31.5*
min 33.0*
Galvanic isolation
Inner conductor in-out
Outer conductor in-out
Screening
Impedance
Connectors
TV
FM
Data
Dimension
13.5 ±1
min 40
9.0 ±1
8.5 ±1
-
–
–
11.0 ±1
10.5 ±1
4.2
min 20.5
min 28.5*
14.0 ±1
13.5 ±1
3.0
mA
mA
–
ohm
<8.5, 230 V AC, 50/60 Hz, <0.7, 2120 V DC for 1 min
<8.5, 230 V AC, 50/60 Hz, <0.7, 2120 V DC for 1 min
Class A
75
–
–
–
mm
IEC-male
IEC-female
F-female
70x68x26
*F>40 MHz, –1,5 dB/oct
EMS
ISO 9001
Environmental Management Standard 14001
Quality Management System
Macab have since many years worked with
the implementation of an environmental
management system. We received the
certification 2008 and we are audited
annually by an independent ISO 14001
registrar. The ISO 14001 EMS standard
is a voluntary international standard for
effectively manage the impact on the
environment.
Since 2008, Macab is one of few companies in the antenna business, achieving
the 9001 quality management standard.
The certification proves that we are
working diligently to establish quality and
performance objectives. The overall aim is
to achieve customer satisfaction through
consistent products and services.
GRG-Macab AS
Lierstranda 82 NO-3400 Lierstranda, Norway
Tlf: +47 32 22 99 90 Fax: +47 32 22 99 91
[email protected]
Macab AB (HEAD OFFICE)
Post: Box 3 SE-231 21 Trelleborg, Sweden
Besök: Vannhögsgatan 7, SE-231 66 Trelleborg
Tel: +46 (0) 410 36 36 10 Fax: +46 (0) 410 36 36 01
[email protected]
Max Nordic A/S
Friis Hansensvej 2 DK-7100 Vejle, Denmark
Telefon: +45 31 68 20 10
[email protected]
www.macab.com