Item Number: QBR-230/510MHz Description: Band Stop Filter

Item Number:
QBR-230/510MHz
Praesto, October 2, 2014 – Rev. 00
Description: Band Stop Filter, Reject 230 to 510 MHz.
DATA SHEET
Electrical
Frequency Range
Impedance
Insertion Loss
Shielding Effectiveness
(Measured with CoMeT)
Dielectric Strength
Insulation Resistance
Specification
5 MHz – 1.000 MHz
75 Ω nominal
Better than
Measured – Worst case of 5 measurements
≤ 1.0 dB
0.72 dB
0.3 – 210 MHz
≤ 2.0 dB
1.09 dB
210 – 220 MHz
≤ 3.5 dB
2,62 dB
220 – 230 MHz
≤ 3.5 dB
2,60 dB
230 MHz
≥ 45 dB
50.9 dB
246 MHz
≥ 45 dB
47.8 dB
246 – 486 MHz
≥ 45 dB
48.3 dB
486 MHz
≤ 3.5 dB
3.00 dB
510 MHz
≤ 3.5 dB
3.07 dB
510 – 530 MHz
≤ 2.0 dB
1.24 dB
530 – 560 MHz
≤ 1.0 dB
0.71 dB
560 – 1.000 MHz
Transfer Impedance @ 5 – 30 MHz
≤ 0.58 mΩ/item
Screening Attenuation @ 30 – 1.000 MHz
≥ 112.4 dB
Screening Attenuation @ 1.000 – 2.000 MHz ≥ 116.1 dB
Screening Attenuation @ 2.000 – 3.000 MHz ≥ 111.3 dB
Class: A++
≥ 2 kV.
≥ 29.99 GΩ @ 500 V.
Standard
IEC 62153-4-3
IEC 62153-4-4
IEC 62153-4-4
IEC 62153-4-4
EN 50117
IEC 61169-1
IEC 61169-1
Environmental
Specification
Temperature range Operating
Temperature range Installation
Corrosion Protection
Standard
-40°C to +60°C
-5°C to +50°C
ASTM B 117-94
Mechanical
Specification
Interface
Standard
IEC 61169-24
F male & female
Material and Finish
Housing
Inner conductor
O’ring
Insulator
Specification
Stainless Steel
Male: Sn (Tin) plated Brass
Female: Sn (Tin) plated Brass with Spring Contact
EPDM
Nylon, Polypropylene
Standard
ASTM B605
ASTM B605
In order to continue to supply the best products, PPC reserves the right to change the products and specifications at any time without prior notice.
PPC Denmark
Branch of PPC Broadband Inc., a Belden Brand
Vaerkstedsvej 14
4720 Praesto
DENMARK
Tel:
+45 5599 1722
Fax: +45 5599 2722
Email: [email protected]
URL: www.ppc-online.com – www.ppc.dk
Item Number:
QBR-230/510MHz
Praesto, October 2, 2014 – Rev. 00
Measurement setup:
Nm-58f, 58m-Fm – QBR-230/510MHz – Nm-Ff.
All results are the worst case result of measurement of 5 filters.
All tests are performed using instruments calibrated in accordance to our ISO 9001
certification.
Insertion Loss and Shielding are measured with Rohde & Schwarz ZNB8 Network
Analyzer, according to IEC standards.
Further test reports, technical specifications and installation instructions can be
obtained on request.
PPC Denmark
Branch of PPC Broadband Inc., a Belden Brand
Vaerkstedsvej 14
4720 Praesto
DENMARK
Tel:
+45 5599 1722
Fax: +45 5599 2722
Email: [email protected]