RNA CVC 9005 Calibration Verification Controls How to Locate a Calibration Control Lot 1. Select Bookmark tab on left: 2. Locate RNA Kit #: • Select appropriate kit • If using the H4 Cartridge, please note sheet specific for H4 3. To Find a Specific Level and Lot: • Open file by selecting the “+” icon • The expanded list of control levels will display IRMA TRUpoint® Calibration Verification Control For use with the RNA Medical, Inc. C V C 9005 C a l i b r a t i o n V e r i f i c a t i o n C o n t r o l s RNA Medical CVC 9005 Calibration Verification Control Kit 3900509 Level 1 Lot 37509 Level 2 Lot 37609 Level 3 Lot 37709 Level 4 Lot 37809 Level 5 Lot 37910 EXP. 06/15 For use with CC, BG, and H3 Cartridges Expected Values Chart * LEVEL 1 2 3 4 5 LOT NUMBER 37509 37609 37709 37809 37910 HCT (%) 15.4 – 21.4 20.6 – 26.6 30.9 – 36.9 43.3 – 49.3 56.7 – 62.7 The values on the Expected Values Chart are based on the results of multiple sample analysis. Samples were drawn with a 1mL syringe, 18 gauge plastic needle tip, after equilibration at 22°C (72°F) for a minimum of 8 hours. Use the expected values for each parameter as a guide in evaluating performance. Since performance is subject to sample temperature and environmental barometric pressure, ITC recommends that each institution establish their own expected values and acceptable limits. The mean values established at your institution should fall within the expected ranges. *NOTE: These values are for use with the IRMA TRUpoint only. CVC9005_CC_3900509_0615 IRMA TRUpoint® Calibration Verification Control For use with the RNA Medical, Inc. C V C 9005 C a l i b r a t i o n V e r i f i c a t i o n C o n t r o l s RNA Medical CVC 9005 Calibration Verification Control Kit 3900509 Level 1 Lot 37509 Level 2 Lot 37609 Level 3 Lot 37709 Level 4 Lot 37809 Level 5 Lot 37910 EXP. 06/15 For use with H4 Cartridges Expected Values Chart * LEVEL 1 2 3 4 5 LOT NUMBER 37509 37609 37709 37809 37910 HCT (%) 16.9 – 22.9 21.3 – 27.3 31.7 – 37.7 43.6 – 49.6 66.4 – 72.4 The values on the Expected Values Chart are based on the results of multiple sample analysis. Samples were drawn with a 1mL syringe, 18 gauge plastic needle tip, after equilibration at 22°C (72°F) for a minimum of 8 hours. Use the expected values for each parameter as a guide in evaluating performance. Since performance is subject to sample temperature and environmental barometric pressure, ITC recommends that each institution establish their own expected values and acceptable limits. The mean values established at your institution should fall within the expected ranges. *NOTE: These values are for use with the IRMA TRUpoint only. CVC9005_H4_3900509_0615
© Copyright 2024 ExpyDoc