Guestroom Control Unit GCU-HOSP Control Interfaces 369708d 1 11.14.2014 Guestroom Control Unit The LutronR Hospitality Guestroom Control Unit coordinates lighting, shades/draperies, and temperature control in a hotel guestroom. It can interface with the hotel Property Management System (PMS) and Building Management System (BMS). Guestroom lighting, shades/draperies, and temperature control can be automated for guest comfort when the room becomes occupied and for energy savings when the room is vacant. The LutronR Hospitality Guestroom Control Unit can integrate with third-party systems via the onboard Ethernet link. Guestroom Control Unit GCU-HOSP Model Number lutron.com GCU-HOSP + 1.800.523.9466 + 44.(0)20.7680.4481 243C IND. CONT. EQ. IEC PELV / NEC® Class 2 Assembled in U.S.A. 50015757 Rev. A ® Job Name: Job Number: S P E C I F I C AT I O N S U B M I T TA L Model Numbers: Page 1 Guestroom Control Unit GCU-HOSP Control Interfaces 369708d 2 11.14.2014 Specifications Power • Processor (P): 24 V- 250 mA System Capabilities •LutronR QS Link allows control and programming of: • Links (L1/L2): 24 V- 2 A per link – Energi Savr NodeT lighting control modules – Wired seeTouchR QS keypads Typical Power Consumption • 5 W; 8 Power Draw Units (PDUs) – PicoR wireless controls – Wired SivoiaR QS motorized shades/draperies Environment • Indoor use only. 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing. – Interfaces for door sensors, window sensors, and room chimes Cooling Method • Passive cooling • Keypad buttons can be programmed to toggle lights, select room scenes, or raise and lower lighting or shades/draperies. Internal Timeclock • ±1 minute per year • Thermostat control link allows control of LutronR room thermostat (LR-HVAC-230-S). • Conditional logic can be programmed to select different actions based on inputs (e.g., time of day). Power Failure Memory • System data stored in non-volatile memory. Timeclock retention for 10 years. Miswire Protection • All terminal block inputs are over-voltage and miswire protected against wire reversals and shorts. Communications Link Wire Type • Two pairs: one pair 18 AWG (0.75 mm2), one pair 18 to 22 AWG (0.75 to 0.34 mm2) twisted, shielded: IEC PELV / NECR Class 2 cable • Total wire length for each link must not exceed 500 ft (152.4 m) Power Supply Wire Type • 18 AWG (0.75 mm2) •LutronR Hospitality Guestroom Control Unit can interface with the hotel Property Management System (PMS) via a wired Ethernet hotel network connection. Software license LGR-OPERA-PR required for Micros Opera PMS interface. •LutronR Hospitality Guestroom Control Unit can interface with the hotel Building Management System (BMS) via a wired Ethernet hotel network connection. Software license LGR-BAC-PR required for native BACnet interface. • BACnet interface allows BMS to monitor and control room lighting, shades/draperies, temperature, room occupancy and vacancy status, and identify system faults. • Lighting load schedule data can be programmed at start-up. This data is used to calculate room lighting power usage, and is available to the hotel BMS for logging and reporting via the native BACnet interface. • Total wire length for each link must not exceed 500 ft (152.4 m) ® Job Name: Job Number: S P E C I F I C AT I O N S U B M I T TA L Model Numbers: Page 2 Guestroom Control Unit GCU-HOSP Control Interfaces 369708d 3 11.14.2014 Specifications (continued) Link Capacities • QS Wired Device Link: maximum 50 devices / 50 zones • Thermostat Control Link: maximum 32 room thermostats Connections • Two 5-pin, removable terminal blocks* for Links 1 and 2. • One 5-pin, removable terminal block* for Power Input. Communication Links • Each Lutron® Hospitality Guestroom Control Unit has three communication links: – Link 1: Lutron® QS wired device link, up to 50 devices and 50 zones – Link 2: thermostat control link, up to 32 room thermostats – Ethernet: used for system start-up and PMS/BMS integration. * Each terminal will accept up to two 18 AWG (0.75 mm2) wires. ® Job Name: Job Number: S P E C I F I C AT I O N S U B M I T TA L Model Numbers: Page 3 Guestroom Control Unit GCU-HOSP Control Interfaces 369708d 4 11.14.2014 Dimensions Dimensions shown as: in (mm) Front View Side View Guestroom Control Unit GCU-HOSP lutron.com + 1.800.523.9466 + 44.(0)20.7680.4481 6.0 (152) 5.26 (134) 243C IND. CONT. EQ. IEC PELV / NEC Class 2 ® Assembled in U.S.A. 50015757 Rev. A 4.27 (108) ® Job Name: Job Number: 1.06 (27) S P E C I F I C AT I O N S U B M I T TA L Model Numbers: Page 4 Guestroom Control Unit GCU-HOSP Control Interfaces 369708d 5 11.14.2014 Mounting (5) Ground (4) Red “L2” Link 2 Power (3) Red “L1” Link 1 Power (2) Red “P” Processor Power (1) Black “COM” Common Guestroom m Control Unit GCU-HOSP lutron.com + 1.800.523.9466 3.9 9466 + 44.(0)20.7680.4481 .4481 243C IND. CONT. EQ. IEC PELV / NEC Class 2 Assembled in U.S.A. L(+) N(-) 120 - 240 V Input / Entrada / Entrée 50015757 Rev. A 24 V Output / Salida / Sortie QSPS-DH-1-60 22.5 - 25 V Wire Landing Boards (QS-WLB) L-LV14 DIN Rail Power Supply (QSPS-DH-1-60) The Guestroom Control Unit can be installed in an HQ-LV21, L-LV21, or L-LV14 enclosure. It is typically powered using the QSPS-DH-1-60 power supply. ® Job Name: Job Number: S P E C I F I C AT I O N S U B M I T TA L Model Numbers: Page 5 Guestroom Control Unit GCU-HOSP Control Interfaces 369708d 6 11.14.2014 System Diagram Example Property Management System (PMS) Guestroom Control Unit Hotel Network Guestroom Control Unit GCU-HOSP lutron.com Lutron Property Management System (PMS) Interface Software + 1.800.523.9466 + 44.(0)20.7680.4481 Building Management System (BMS) 243C IND. CONT. EQ. IEC PELV / NEC® Class 2 Assembled in U.S.A. 50015757 Rev. A 0,5 N•m All Others Input Hi Temp L Program Switching Power Module LQSE-4S10-D Power www.lutron.com +44.(0)20.7680.4481 N 230 V~ 50/60 Hz 50 mA 8 mm 1,2 N•m Mains Only Z096 Zone 1 Zone 2 Zone 3 Zone 4 COM COM CCI QS MUX CCI MUX Room Thermostat Def Opt1 Opt2 µ H Option M L Opt3 Outputs 230 V~ 10 AX each 1 2 3 Up 4 DIN Rail Power Module International seeTouchR Keypad Designer seeTouchR Keypad QS Sensor Module (QSM) PicoR Wireless Control SivoiaR QS Motorized Roller Shades ® Job Name: Job Number: S P E C I F I C AT I O N S U B M I T TA L Model Numbers: SivoiaR QS Motorized Drapery Radio Powr SavrT Occupancy/ Vacancy Sensor Door Switch Contact Door Window Chime Switch Contact Corridor I/O Page 6
© Copyright 2024 ExpyDoc