Haldimand County Nanticoke WTP Upgrades JLR No. 26215/PW-ES-014-059 SECTION 00901 ADDENDUM NO. 7 PAGE 1 December 3, 2014 Addendum 7 PW-ES-014-059: NANTICOKE WATER TREATMENT PLANT UPGRADES The following is provided to bidders as additional information and/or clarification and/or in response to questions. This Addendum forms part of the Contract Documents and amends the original Drawings and Specifications. Ensure that all affected parties are aware of the items noted and include any and all cost impacts in the Tender submission. SPECIFICATIONS A7.1 SECTION 01340 – SHOP DRAWINGS, PRODUCT DATA AND SAMPLES NOTE: In response to inquiries from contractors and potential suppliers specific reference is made to 01340, Article 5.6. As noted in 01340, Article 5, alternatives proposed by the contractor following award of tender will be considered on an individual basis. Alternatives will be evaluated at the sole discretion of the Owner based on cost, technical, or schedule advantages. A7.2 SECTION 15200 – PROCESS EQUIPMENT .1 Article 2.1.2 Modify: A7.3 “Inlet Air Flow: 600 L/s” to read “Inlet Air Flow: 400 L/s” SECTION 15201 - FILTRATION EQUIPMENT, FILTER MEDIA AND UNDERDRAIN SYSTEM .1 Article 2.1 Modify article to read: “Provide three (3) Backwash troughs (Troughs) to be a formed bottom design…” Cayuga Administration Office 45 Munsee Street North, P.O. Box 400, Cayuga, Ontario N0A 1E0 Phone: (905) 318-5932 · Fax: (905) 772-3542 www.haldimandcounty.on.ca Haldimand County Nanticoke WTP Upgrades JLR No. 26215/PW-ES-014-059 A7.4 PAGE 2 SECTION 15322 – CHEMICAL FEED SYSTEMS .1 Article 1.3.3 Add: A7.5 SECTION 00901 ADDENDUM NO. 7 “series”. Article to read “Section 15400 series” SECTION 15349 – PROCESS PIPING AND VALVES .1 .2 Article 2.11.1 Modify: “AWWA C509 suitable …” To read: “AWWA C500 suitable…service. Include max 300 dia operator with gear, as required by size of valves and manufacturer requirements.” Article 2.15.10 Add: .4 “.5 Article 2.32 (Addendum A2.4) Add: “.13 .2 .5 Alternate Manufacturer: Claval” Article 2.33 (Addednum A2.4) Add: .6 JASH USA Inc” “.5 Alternate Manufacturer: Clow” Article 3.16.1.3 Delete: “15400” Replace with: “15401” .7 Valve Schedule Delete: A7.6 Addendum Item A2.4.1 – Valve Schedule SECTION 15748 – UNIT HEATERS – GAS-FIRED, POWER VENTED .1 Article 2.1 Delete: ”, Blower Type” Replace with: “Horizontal Throw” Cayuga Administration Office 45 Munsee Street North, P.O. Box 400, Cayuga, Ontario N0A 1E0 Phone: (905) 318-5932 · Fax: (905) 772-3542 www.haldimandcounty.on.ca Haldimand County Nanticoke WTP Upgrades JLR No. 26215/PW-ES-014-059 .2 SECTION 00901 ADDENDUM NO. 7 PAGE 3 Article 2.1.1 Delete: “Provide high efficiency, power vented, gas fired, blower type industrial unit heaters for ducted installation, meeting scheduled operating criteria.” Replace with: “Provide high efficiency, power vented, gas fired, propeller fan industrial type unit heaters for horizontal throw, meeting scheduled operating criteria.” .3 Article 2.1.2.3 Delete: “Centrifugal fan” Replace with: “direct drive propeller fan .4 Article 2.1.2.6 Delete: “duct connection” Replace with: “adjustable vertical and horizontal type.” .5 Article 2.1.3.3 Delete: “two stage” Replace with: “single stage” A7.7 SECTION 15800 – VENTILATING .1 Article 1.1.3 Add: A7.8 “series”. Article to read “Section 15400 series” SECTION 16801 – 600 VOLT MCCS .1 Article 2.17.1 Add: “Allen Bradley/Rockwell Automation Ethernet 2100 Series with Intellicenter is the specified product. Alternative Products will be considered in accordance with Section 01340, Article 5, only after the Contract Award to the successful bidder.” Cayuga Administration Office 45 Munsee Street North, P.O. Box 400, Cayuga, Ontario N0A 1E0 Phone: (905) 318-5932 · Fax: (905) 772-3542 www.haldimandcounty.on.ca Haldimand County Nanticoke WTP Upgrades JLR No. 26215/PW-ES-014-059 SECTION 00901 ADDENDUM NO. 7 PAGE 4 DRAWINGS A7.9 ELECTRICAL DRAWINGS – GENERAL .1 Panel JB-831 to be renamed as LCP-832. A7.10 DRAWING E003 – SINGLE LINE DIAGRAM .1 Add note: There are no discernable markings on the switchgear to conclusively identify the manufacturer. However, the styling of the cabinet is consistent with that of the adjacent Cutler-Hammer MCC. Refer to attached as-constructed drawings (B-74376-E501 - Single Line Diagram and Sub-Station Layout (Proctor & Redfern Limited, April 1978) and R-4470-1 OCWA Haldimand-Norfolk RegionControl Building & Misc Works-Single Line & Substation Layout (June 2004)). A7.11 DRAWING E009 – CABLE SCHEDULES SHEET 2 .1 Conductor count of DC-831010 to be increased to 30c in lieu of 20c. A7.12 DRAWING I001-CONTROL SYSTEM BLOCK DIAGRAM .1 Conductor count of DC-831010 to be increased to 30c in lieu of 20c. A7.13 DRAWING P350 – SECTIONS AND DETAILS .1 Refer to the attached sketch SKP350-01 for filter drain connections. A7.14 DRAWING – PM004 – STANDARD DETAILS .1 Refer to the attached sketch SKPM004-01 for details of pipe penetration through clarifier effluent channel. A7.15 DRAWING – S311 – GROUND LEVEL PLAN .1 Refer to the attached sketch SKS311-02 for the location of the micro-sand recirculation pipe penetration and the relocation of the filter influent opening and associated partial slab and handrails. A7.16 APPENDIX C – SHOP DRAWINGS – JLR004 .1 Refer to the attached Pre-selected Equipment Supplier revised Field Installation Guide that modifies the Clarifier Effluent Channel Penetration for the Microsand Recirculation Piping. Cayuga Administration Office 45 Munsee Street North, P.O. Box 400, Cayuga, Ontario N0A 1E0 Phone: (905) 318-5932 · Fax: (905) 772-3542 www.haldimandcounty.on.ca Haldimand County Nanticoke WTP Upgrades JLR No. 26215/PW-ES-014-059 SECTION 00901 ADDENDUM NO. 7 PAGE 5 Declaration: Bidders must acknowledge receipt of Addendum #7 by signing the addendum and including with your submission. Signature of Bidder Representative Date END OF ADDENDUM NO. 7 Cayuga Administration Office 45 Munsee Street North, P.O. Box 400, Cayuga, Ontario N0A 1E0 Phone: (905) 318-5932 · Fax: (905) 772-3542 www.haldimandcounty.on.ca PROJECT: 1 S311 NANTICOKE WATER TREATMENT PLANT UPGRADES GROUND FLOOR PLAN 33 HALDIMAND RD 55, NANTICOKE, ON, N0A 1L0 0 1 2 4 6 8m SCALE: 1:100 DRAWING: RELOCATED FILTER GATES AND PIPE PENETRATION AT EFFLUENT CHANNEL www.jlrichards.ca This drawing is copyright protected and may DESIGN: not be reproduced or used for purposes DRAWN: other than execution of the described work without the express written consent of CHECKED: J.L. Richards & Associates Limited. DAY JLR NO: JIC DRAWING NO.: DAY 26215 SKS311-02 December 2, 2014 1:18:42 PM 02 PLOT DATE: File Location: P:\26000\26215 - Nanticoke Water Treatment Plant\JLR DWG\Struct\26215 GROUND FLOOR.dwg 02
© Copyright 2024 ExpyDoc