Leise klinische MR-Bildgebung D. Grodzki, Siemens Healthcare Unrestricted © Siemens AG 2014 All rights reserved. Answers for life. Acoustic noise in MRI • Main source of acoustic noise: gradient coil • Gradient coil acts like a membrane due to fast gradient switching • Reduction of acoustic noise with hardware measures • Dampening of the coil, vacuum chamber, … • Reduction of acoustic noise with software measures • Minimization of gradient activity in sequence design Unrestricted © Siemens AG 2014 All rights reserved. Magnetic Resonance Sequences with low gradient activity: Techniques • Best case: Gradients are always constant • Sequences with (almost) constant gradients: PETRA1*, SILENZ / zTE2, SWIFT3 • No noise from gradient system • Gradients switched on before none-selective excitation4 • zTE: Very fast Tx/Rx switching needed (< 10µs) • PETRA: Cartesian sampling of k-space center • Can be used with every coil [1]: Grodzki et al, MRM 2012; [2]: Weiger et al. MRM 2011; [3]: Idiyatullin et al. JMR 2006; [4]: Grodzki et al, JMR 2012 Unrestricted © Siemens AG 2014 All rights reserved. *The products/features (here mentioned) may not be commercially available in all countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact your local Siemens organization for further details. Magnetic Resonance Sequences with low gradient activity: Contrasts • Contrast w/o pre-pulses in the PD to T1 range • Ultrashort echo times, signal from bones etc. • Pre-pulses needed for other contrasts: T1, T2, MRA • T1 contrast with inversion pulses • Acquisition scheme comparable to MPRAGE • PETRA*: reordering of k-space center for high SNR and CNR 180° TI 180° TACQ TW Acquisition of 200-500 repetitions Unrestricted © Siemens AG 2014 All rights reserved. *The products/features (here mentioned) may not be commercially available in all countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact your local Siemens organization for further details. Magnetic Resonance PETRA* volunteer scanning (MAGNETOM Trio, 3T)+ MPRAGE 95.0 dB(A) Unrestricted © Siemens AG 2014 All rights reserved. PETRA* 64.9 dB(A) *The products/features (here mentioned) may not be commercially available in all countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact your local Siemens organization for further details. Magnetic Resonance +Data on file; results may vary. PETRA* patient scanning (M 57, MAGNETOM Trio, 3T) MPRAGE 95.0 dB(A) PETRA* MPRAGE PETRA TE 2.44 ms 0.07 ms Res. 0.952 x 1.0 mm 0.953mm TScan 5:54 5:51 PAT 2 - Courtesy Dr. Ida of Ebara Hospital Tokyo, Japan 64.9 dB(A) PETRA can be a quiet alternative for the MPRAGE sequence1 [1]: Ida et al, JMRI 2014 Unrestricted © Siemens AG 2014 All rights reserved. *The products/features (here mentioned) may not be commercially available in all countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact your local Siemens organization for further details. Magnetic Resonance Automated sequence optimization • Gradient “Translation” algorithm • Sequence independent approach • Can be attached to every sequence • Automated gradient smoothing Principle: 1. Segment incoming sequence into CHANGE and KEEP (TX, RX, FC, DW) 2. Optimize gradients in CHANGE intervals 3. Send out optimized sequence Optimization IDEA Sequence Framework Measurement System Unrestricted © Siemens AG 2014 All rights reserved. Magnetic Resonance T2 TSE head imaging+ Conventional TSE matrix 512, TA 2:06 min 88.8 dB(A) Unrestricted © Siemens AG 2014 All rights reserved. QuietX* TSE matrix 512, TA 2:08 min 74.4 dB(A) *The products/features (here mentioned) may not be commercially available in all countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact your local Siemens organization for further details. +Data on file; results may vary. Magnetic Resonance QuietX+ Complete, quiet orthopedic examinations QuietX+ Conventional QuietX+ Conventional QuietX+ Conventional 80% 72% 70% reduction* reduction* reduction* PD TSE, 88 dBA, TA 3:53 PD TSE, 74 dBA, TA 3:53 Unrestricted © Siemens AG 2014 All rights reserved. T1 TSE, 92 dBA, TA 0:58 T1 TSE, 81 dBA, TA 0:58 T2 TSE, 89 dBA, TA 4:14 T2 TSE, 79 dBA, TA 4:14 *Reduction in sound pressure. Data on file. Results may vary. not be commercially available in countries outside the U.S., future availability cannot be guaranteed. +May Magnetic Resonance Results* • Complete quiet Neuro and MSK examinations, including EPI DWI+ • Noise reduction of 10-25 dB(A) • Optimization can be attached to any sequence • Inaudible scanning with PETRA+ • No hardware changes needed Unrestricted © Siemens AG 2014 All rights reserved. +The products/features (here mentioned) may not be commercially available in all countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact your local Siemens organization for further details Magnetic Resonance * Data on file; results may vary. Vielen Dank für Ihre Aufmerksamkeit! Unrestricted © Siemens AG 2014 All rights reserved. Answers for life. Magnetic Resonance
© Copyright 2024 ExpyDoc