NEST thermostat ADAPTER v.3 22 If you have device which cannot be controlled with 24V AC power supply, and can’t be connected directly to NEST thermostat, NEST thermostat adapter allow you to connect NEST thermostat to any two devices which can be activated with closing circuit which doesn’t exceed 220V and 1A power consumption. With NEST thermostat ADAPTER is easy and simple to connect your NEST thermostat to any devices which isn’t suitable to regulate with 24V DC power supply. It has possibility to connect maximum of two separate devices. If you need more devices to control just by another ADAPTER. If your devices consume more power than ADAPTER relay output can provide (220V, 1A) you can add additional relay corresponding power consumption. If you aren’t familiar with wiring and electrical connection, please ask help of professional. Technical specification of NEST thermostat ADAPTER Power input: 220V AC, 2.4W, max 1.5mm² wire Power output: 24V AC, 0.1A, max 0.5mm² wire REL output: 2 x 220V, 1A, max 0.5mm² wire Dimension: 88x34x52mm For terminal connector screw use 2,0x40 screwdriver Allow you to connect 2 NEST thermostat controlling output. Connection diagram N/L Rh C Y1 input 220V AC connection Connect to NEST Rh connector (or Rc), provides 24V AC power supply to NEST Connect to NEST C connector, provides 24V AC power supply to NEST Connect to NEST any output connector you wish to use. It activates REL Y1 output If used for heating, connect it on Y1 NEST connector, and REL Y1 connect to cooling unit activation W1 Connect to NEST any output connector you wish to use. It activates REL W1 output If used for heating, connect it on W1 NEST connector, and REL W1 connect to heating unit activation REL Y1 NO (normal open) relay output (max. 220V AC, 1A) for activation any desirable devices When NEST activate Y1 input REL output is shorted (closed) REL W1 NO (normal open) relay output (max. 220V AC, 1A) for activation any desirable devices When NEST activate W1 input REL output is shorted (closed) LED explanations POW (green) LED: No light check 220V AC Light 220V AC exist Light bright NEST connected properly Light brightest short circuit on NEST connection wires (C, Rh) OUTPUT LED: Light RED W1 input/output activated Light YELOW Y1 input/output activated Connection diagram, option with heating/cooling and heating/additional heating 220VAC 220VAC N N L POW LED L POW LED NEST thermostat adapter NEST thermostat adapter R REL REL Y W Y1 W1 1 1 C h R REL REL Y W Y1 W1 1 1 C h cooling activation aditional heater heating activation heating activation Connection detection on NEST thermostat Wires present on Rc and C terminal, but here is no any (or appropriate) power supply connected. Wires present on Rc, C and W1 terminal. Only on W1 is equipment detected. There is no power supply. Wires present on Rc, C and W1 terminal. Appropriate power on RC and C detected. On W1 heating equipment detected. R REL REL Y W Y1 W1 1 1 C h NEST thermostat adapter POW LED VAILANT ecoTEC plus (612/615/618/624/824/pro24…) example connection Security system – automation – acoustic – multimedia / design – sales –installation –maintenance – service KBZ ELEKTRONIC d.o.o. Trnjanska cesta 117, 10000 Zagreb, Croatia, Establish: 1992.god. Web: www.kbz-electronic.com , Mail: [email protected]
© Copyright 2024 ExpyDoc