Info KTW

Customer
Product Producer
owner of the
composition
UBA-guidelines
Secrecy Agreement
Disclosure of the composition details
information
1)
order for composition
check-up
assessment time depends on the
disclosure process with the owner
of the composition
usually 8 – 26 weeks
2)
order for
migration test
Test samples after
consultation with TZW
Test duration ca. 10-12 weeks,
depending on the scope
3)
KTW
TZW-Test Centre
http://www.umweltbundesamt.de/en/topics
/water/drinking-water/distributing-drinkingwater/guidelines-evaluation-criteria
composition check-up
(evaluation of documents)
according to UBA guidelines
conformance
with positive
lists?

no

information of customer
and owner of the
composition about
negative result
fees
(per composition)
350-650 €
yes
migration test
1. Cold water
2. Warm- or hot water
conformance
with UBA
requirements?
no
test report
 KTW noncompliance
yes
test certificate 
 KTW compliance
15.10.2014,

fees
(cold water)
POM ca. 3.000 €
PA ca. 2.000 €
PE ca. 1.000 €
ABS ca. 1.500 €
rubber ca. 4.000 €
depending on the
composition
updated 15th October 2014
page 2 of 2
Information for KTW-testing
Scope
By means of the testing according to KTW Guideline, Coatings Guideline, Lubricant Guideline, and
Elastomer Guideline it is determined if substances from the tested non-metallic product were
released into the drinking water and therefore non tolerable changes of the drinking water could
occur.
Recipe (chemical formulation)
By recipe is meant the detailed chemical composition of the material that is used to manufacture
the product. The recipe in dependence of the material type has to be in accordance in each case
to the applicable positive list of KTW Guideline, Coatings Guideline, Lubricant Guideline and
Elastomer Guideline.
For the disclosure of the recipe a secrecy agreement can be concluded. On demand we will send
you our template.
Migration test
After passing the examination of the recipe, the migration test will be performed according the requirements of the respective guideline according to DIN EN 12873-1. The test is always performed
at 23 ± 2 °C. In addition the temperature ranges of 60 ± 2 °C and 85 ± 2 °C can be included. In the
test water the basic requirements and the additional requirements that are arising from the recipe
examination will be examined
The required test samples for the migration tests have to be agreed directly with the TZW.
Test-procedure and –duration
The test-duration depends basically on the completeness of the recipe disclosure. It has to be
considered, that often pre-suppliers have to be involved in the recipe review. In this case we also
conclude secrecy agreements with the pre-suppliers.
After the recipe review has been done the test-duration for the cold water and warm or hot water
tests is usually about 10-12 weeks.
Das Technologiezentrum Wasser ist eine
Einrichtung des DVGW Deutscher Verein
des Gas- und Wasserfaches e.V.
– Technisch-wissenschaftlicher Verein –
Technologiezentrum Wasser
Prüfstelle Wasser
Wasserwerkstraße 4
76137 Karlsruhe, Germany