DERMATOLOGY AND AESTHETIC MEDICINE MEDICAL DIVISION Asset Extremely Powerful and Compact Yag / KTP Q-Switched Laser MULTICOLOUR TATTOO REMOVAL BENIGN PIGMENTED LESIONS TREATMENTS SKIN REJUVENATION PROCEDURES PERMANENT HAIR REDUCTION VASCULAR LESIONS TREATMENTS ABLATIVE FRACTIONAL REJUVENATION (TWAIN OPTIONS) This brochure is not intended for the USA market. Certain Intended Uses/Configurations/Models/Accessories are not cleared for USA Extremely Powerful and Compact THE Q-SWITCHED MODE This modality delivers extremely short laser pulses, each one of just 6ns, able to produce the really high optical peak power (hundreds of Mega-Watts) needed to enable an efficient photoacoustic effect and to reduce eventual skin overheating. As a result, the unwanted pigments are fragmented in small particles and subsequently removed by phagocytosis. Flat top OptiBeam technology(*) An exclusive characteristic of Quanta System’s Q-Switched lasers is the square and flat top laser beam profile provided by the OptiBeam technology. This feature assures safe and effective treatments thanks to its homogeneous energy delivery over all the spot area. This technology performs also a very precise coverage of the area to be treated thanks to the squared shape of the laser spot which protects from excessive pulse overlaps. ASSET FEATURES OPTIONS The Asset laser combines Nd:Yag 1064/532 nm wavelengths with energy per pulse up to 1000 mJ in QSwitched mode in a compact footprint. The power of the device is state-of-the-art in the market and enables coverage of all the treatment modalities. (*) Optional Flat-Top laser energy distribution over the spotsize by OptiBeam FR Mode (Free Running Mode) Asset is able to operate in Rejuvenation Mode. With the FR Mode, the Nd:Yag 1064 nm laser can deliver pulses with duration of 0.3 ms at very high repetition rates, to perform quick and efficient skin photo rejuvenation and tightening of all the skin types. The use of FR Mode extends the application range to a complete nonablative anti-aging program. TWAIN Asset can be equipped with the optional Twain connector to be enabled for the use of Twain IPL and Twain 2940 handpieces. Twain IPL is used to perform all the standard treatments of Quanta System’s stand-alone IPL. Twain 2940 is a powerful Er:Yag laser with a built-in gun handpiece for Fractional Skin Resurfacing and Skin Ablation Treatments. HANDPIECES Twain IPL handpiece OptiBeam handpieces TWAIN universal connector has a special optional connector for Twain handpieces Twain 2940 handpiece Asset CLINICAL RESULTS TATTOO REMOVAL Courtesy of Nicola Zerbinati MD TATTOO REMOVAL Courtesy of Matteo Tretti Clementoni MD Before After 7 treatments Before PIGMENTED LESIONS OTA NEVUS Courtesy of Galimberti MD Courtesy of Paolo Sbano MD Before After 4 treatments Before PIGMENTED LESIONS Courtesy of Matteo Tretti Clementoni MD Before After 5 treatments After 1 treatment SKIN REJUVENATION Courtesy of Dhami MD After 1 treatment Before After 4 treatments DERMATOLOGY AND AESTHETIC MEDICINE MEDICAL DIVISION Asset MODEL Asset Laser [nm] Wavelength Nd:Yag 1064 532 Pulse width Q-Switch mode [ns]6 Pulse width FR mode [μs]100-300 Repetition rate [Hz] up to 10 [mm] 2x2; 3x3; 4x4; 5x5 or round(*) Ø 2; 3; 4; 6 Spot size Fluence Q-Switch mode(**) [J/cm2] up to 28 up to 14 Fluence FR mode(**) [J/cm2] up to 50 - Electrical requirements 230 V ac; 10 A; 50/60 Hz Dimensions and weight 244(W) x 790 (L) x 790 (H) mm; 60 Kg Dimensions and weight with Twain connector 244(W) x 840 (L) x 920 (H) mm; 70 Kg (*) Optional (**) With round handpieces OPTION Twain 2940 Twain IPL Source Er:Yag Wavelength [nm] 2940 Pulse width [ms] 0.3 ÷ 1 5-240 Repetition rate [Hz] up to 6 0,5 2, 4, 9 9 (fractional) 48x13 mm - 25x13 mm up to 95 @ 2 mm up to 30 Spot size [mm] [J/cm2] Fluence Filtered Xenon Flashlamp 650-1200 625-1200 590-1200 570-1200 2 550-1200 400-1200 2 VISIBLE AND INVISIBLE LASER RADIATION Avoid eye or skin exposure to direct or scattered radiation. Class 4 laser product Maximum Energy 1 J / 0.5 J 6 ns / 6 ns Wavelenght Aiming beam Standard 1064nm / 532 nm Class 3R IEC/EN 60825-1: 2007 3mW@635 nm Cod. DBM000056.01 Pulse duration CAUTION - Laser radiation Note: National local authorities may put restrictions to the parameters indicated in the above table, or may limit or remove certain intended uses. Specifications are subject to change without notice. Quanta System S.p.A Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy Tel. +39 0331.376797 - Fax +39 0331.367815 [email protected] www.quantasystem.com QTS-ASSET-rev003- ROTW Quanta System products are manufactured according to the International standards and have been cleared by the most important International notified bodies. The Company is EN ISO 9001:2008 and EN ISO 13485:2012 certified. Quanta System S.p.A. was founded in 1985 and belongs to the EI. En. Group (a public company listed in the Star segment of the Italian Stock Exchange) since January 2004. The company, divided into three business units (medical, scientific and industrial) is specialized in manufacturing of laser and opto-electronic devices.
© Copyright 2024 ExpyDoc