Extremely Powerful and Compact Yag / KTP Q

DERMATOLOGY AND
AESTHETIC MEDICINE
MEDICAL DIVISION
Asset
Extremely Powerful and Compact
Yag / KTP Q-Switched Laser
MULTICOLOUR TATTOO REMOVAL
BENIGN PIGMENTED LESIONS TREATMENTS
SKIN REJUVENATION PROCEDURES
PERMANENT HAIR REDUCTION
VASCULAR LESIONS TREATMENTS
ABLATIVE FRACTIONAL REJUVENATION
(TWAIN OPTIONS)
This brochure is not intended for the USA market. Certain Intended Uses/Configurations/Models/Accessories are not cleared for USA
Extremely Powerful and Compact
THE Q-SWITCHED MODE
This modality delivers extremely short
laser pulses, each one of just 6ns, able
to produce the really high optical peak
power (hundreds of Mega-Watts)
nee­ded to enable an efficient photoacoustic effect and to reduce eventual
skin overheating.
As a result, the unwanted pigments
are fragmented in small particles and
subsequently removed by phagocytosis.
Flat top OptiBeam technology(*)
An exclusive characteristic of Quanta
System’s Q-Switched lasers is the
square and flat top laser beam profile
provided by the OptiBeam technology.
This feature assures safe and effective treatments thanks to its homogeneous energy delivery over all the
spot area.
This technology performs also a very
precise coverage of the area to be
treated thanks to the squared shape
of the laser spot which protects from
excessive pulse overlaps.
ASSET FEATURES
OPTIONS
The Asset laser combines Nd:Yag
1064/532 nm wavelengths with energy per pulse up to 1000 mJ in QSwitched mode in a compact footprint. The power of the device is
state-of-the-art in the market and
enables coverage of all the treatment
modalities.
(*) Optional
Flat-Top laser energy distribution over
the spotsize by OptiBeam
FR Mode (Free Running Mode)
Asset is able to operate in Rejuvenation Mode. With the FR Mode, the
Nd:Yag 1064 nm laser can deliver
pulses with duration of 0.3 ms at
very high repetition rates, to perform
quick and efficient skin photo rejuvenation and tightening of all the skin
types.
The use of FR Mode extends the application range to a complete nonablative anti-aging program.
TWAIN
Asset can be equipped with the optional Twain connector to be enabled
for the use of Twain IPL and Twain
2940 handpieces.
Twain IPL is used to perform all the
standard treatments of Quanta System’s
stand-alone IPL.
Twain 2940 is a powerful Er:Yag laser with a built-in gun handpiece for
Fractional Skin Resurfacing and Skin
Ablation Treatments.
HANDPIECES
Twain IPL handpiece
OptiBeam handpieces
TWAIN universal connector
has a special optional
connector for
Twain handpieces
Twain 2940 handpiece
Asset
CLINICAL RESULTS
TATTOO REMOVAL
Courtesy of Nicola Zerbinati MD
TATTOO REMOVAL
Courtesy of Matteo Tretti Clementoni MD
Before
After 7 treatments
Before
PIGMENTED LESIONS
OTA NEVUS
Courtesy of Galimberti MD
Courtesy of Paolo Sbano MD
Before
After 4 treatments
Before
PIGMENTED LESIONS
Courtesy of Matteo Tretti Clementoni MD
Before
After 5 treatments
After 1 treatment
SKIN REJUVENATION
Courtesy of Dhami MD
After 1 treatment
Before
After 4 treatments
DERMATOLOGY AND
AESTHETIC MEDICINE
MEDICAL DIVISION
Asset
MODEL Asset
Laser [nm] Wavelength Nd:Yag
1064
532
Pulse width Q-Switch mode
[ns]6
Pulse width FR mode
[μs]100-300
Repetition rate [Hz]
up to 10
[mm]
2x2; 3x3; 4x4; 5x5 or round(*) Ø 2; 3; 4; 6
Spot size Fluence Q-Switch mode(**) [J/cm2] up to 28
up to 14
Fluence FR mode(**) [J/cm2] up to 50
-
Electrical requirements
230 V ac; 10 A; 50/60 Hz
Dimensions and weight
244(W) x 790 (L) x 790 (H) mm; 60 Kg
Dimensions and weight with Twain connector
244(W) x 840 (L) x 920 (H) mm; 70 Kg
(*) Optional
(**) With round handpieces
OPTION
Twain 2940 Twain IPL
Source
Er:Yag
Wavelength [nm] 2940
Pulse width [ms]
0.3 ÷ 1 5-240
Repetition rate
[Hz] up to 6
0,5
2, 4, 9
9 (fractional)
48x13 mm - 25x13 mm
up to 95 @ 2 mm
up to 30
Spot size
[mm] [J/cm2] Fluence Filtered Xenon Flashlamp
650-1200
625-1200
590-1200
570-1200
2
550-1200
400-1200
2
VISIBLE AND INVISIBLE LASER RADIATION
Avoid eye or skin exposure to direct or scattered radiation.
Class 4 laser product
Maximum Energy
1 J / 0.5 J
6 ns / 6 ns
Wavelenght
Aiming beam
Standard
1064nm / 532 nm
Class 3R
IEC/EN 60825-1: 2007
3mW@635 nm
Cod. DBM000056.01
Pulse duration
CAUTION - Laser radiation
Note: National local authorities may put restrictions to the parameters indicated in the above table, or may limit or remove certain intended uses.
Specifications are subject to change without notice.
Quanta System S.p.A
Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39 0331.376797 - Fax +39 0331.367815
[email protected]
www.quantasystem.com
QTS-ASSET-rev003- ROTW
Quanta System products are manufactured according to the International standards and have been cleared by the most important International notified
bodies. The Company is EN ISO 9001:2008 and EN ISO 13485:2012 certified. Quanta System S.p.A. was founded in 1985 and belongs to the EI. En. Group
(a public company listed in the Star segment of the Italian Stock Exchange) since January 2004. The company, divided into three business units (medical,
scientific and industrial) is specialized in manufacturing of laser and opto-electronic devices.