Turbine Flow Meter KOTGQ SERIES [Temperature and Pressure Compensation] KOTQ Series는 온도와 압력 보상이 가능한 가스 터빈 유량계입니다. Temperature and Pressure compensation, normative flow can be displayed . ■ Technical Data Measuring system Gas: Natural Gas, LPG, Air (1) Dry gas without water (2) Gas without corrosion Application range Measured Value Primary measured value Secondary measured value Tertiary measured value Flow Rate Volume flow Temperature; Pressure (ONLY available for compensation model) Design Features Modular construction The measurement system consists of a flow sensor and a signal converter. It is available as compact and as separate version. Compact version converter Compensation Type D1: Local Display; 24V DC Power; Dual Power: Battery;4‐20mAOutput(3‐wire);SIRERS485 D2: Local Display: 24V DC Power; Dual Power: Battery;4‐20mAOutput(2‐wire);ModbusRS485 Connection Thread: DN25‐DN50 Flange: DN25‐DN300 (DIN, ANSI, JIS) Measurement Ratio Standard – 10:1; Optional: 20:1 인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체 (주) 플 로 우 닉 스 - 14 - T E L : 82-32-579-2999 E-MAIL : [email protected] Turbine Flow Meter Measuring accuracy Reference conditions Flow Meter Accuracy Flow conditions similar to ISO 9951 Medium: Gas Temperature: +10...+30°C / +50...+86°F Inlet section: ≥ 10 DN Operating pressure: 1 bar / 14.5 psig Standard: 1.5% Qmin to 0.2Qmax: 3%; 0.2Qmax to Qmax: 1.5% Optional: 1.0% Qmin to 0.2Qmax: 2%; 0.2Qmax to Qmax: 1.0% Operating conditions Temperature Process temperature Ambient temperature (all versions) Storage temperature Pressure EN 1092‐1 ASME B16.5 JIS ‐20...+80°C Standard (with aluminum converter housing): ‐10…+55°C ‐20...+70° DN25…DN300: PN 16 Other pressures on request 1”...12": 150 lb RF Other pressures on request 1”...12": 10 K Other pressures on request Installation conditions Installation For detailed information see chapter "Cautions for Installation" Flow direction Forward Arrow on flow sensor indicates flow direction. Inlet run Outlet run ≥ 10 DN ≥ 5 DN Materials Sensor housing Flanges Rotor Bearings and Shaft Converter Housing SS304 Other materials on request SS304 Other materials on request ABS Plastic (Acrylonitrile ‐ Butadiene – Styrene) Aluminum Alloy SS304 Standard: polyurethane coated die‐cast aluminum 인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체 (주) 플 로 우 닉 스 - 15 - T E L : 82-32-579-2999 E-MAIL : [email protected] Turbine Flow Meter ■ Model and Selection Table 1: Model Selection Guidance for Gas Turbine Flowmeter Model Suffix Code Description KOTGQ‐ Local display; 24V DC and Battery Power; 3‐wire 4‐20mA Output SURE RS485 Protocol Local display; 24V DC and Battery Power; 2‐wire 4‐20mA Output Modbus RS485 Communication D1‐ Converter D2‐ Diameter Three Digitals; for example: 025: 25 mm; 050: 50 mm; 125: 125 mm; 300: 300 mm XXX Flow range S(x) W(x) S L Body Material Rotor Material Explosion Level S L N E1 E2 ‐DXX Connection ‐AX ‐JX ‐TH Accuracy ‐N ‐G1 Refer to flow range table Refer to flow range table SS304 Cast Aluminum ABS Plastic Aluminum Alloy Safety Field without Explosion ExiaIICT4 ExdIIBT6 DXX: D06, D10, D16, D25, D40 D06: DIN PN6; D10: DIN PN10 D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600# JX: J1, J2, J4 J1: JIS 10K; J2: JIS 20K; J4: JIS 40K Thread; DN4…DN50 1.5% 1.0% Model Code: LWQ‐D1‐100S1SLN‐D16‐N Explanation ‐ Converter: battery power mode without output; Diameter: 100mm; Flow range: 20‐400 m3/h; Body Material: SS304; Rotor Material: Aluminum Alloy; No Explosion; Connection: DIN PN16 Flange; Accuracy: 1.5% 인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체 (주) 플 로 우 닉 스 - 16 - T E L : 82-32-579-2999 E-MAIL : [email protected] Turbine Flow Meter Measurable Flow Rate Range: Note: The flow range as blow is based on operating status; REFERENCE ONLY. Consult the factory if you have special requirement. Refer to the nameplate or certificate for actual flow range. Nominal Diameter (mm) (in.) Standard Flow Range (SFR) Code (m3/h) Standard Pressure Rating (MPa) Extended Flow Range (EFR) Code (m3/h) 25 1 S 2.5 to 25 W 4 to 40 40 1.5 S 5 to 50 W 6 to 60 50 2 S1 S2 6 to 65 10 to 100 W1 W2 5 to 70 8 to 100 65 2.5 S 15 to 200 W 10 to 200 80 3 10 to 160 4 15 to 300 20 to 400 20 to 400 32 to 650 W 100 S1 S2 S1 S2 W 13 to 250 125 5 S 25 to 700 W 20 to 800 150 6 80 to 1600 8 W 50 to 1000 250 10 32 to 650 50 to 1000 80 to 1600 130 to 2500 130 to 2500 200 to 4000 W 200 S1 S2 S1 S2 S1 S2 W 80 to 1600 300 12 S 200 to 4000 W1 W2 130 to 2500 320 to 6500 400 16 S 400 to 8000 W 260 to 8000 1.6 ■ Cautions for Installation Mounting Positions Avoid all pipe locations where the flow is pulsating, such as in the outlet side of piston or diaphragm pumps. Avoid locations near equipment producing electrical interference such as electric motors, transformers, variable frequency, etc. Install the meter with enough room for future access for maintenance purposes. Warning: Precaution for direct sunshine and rain when the meter is installed outside. 인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체 (주) 플 로 우 닉 스 - 17 - T E L : 82-32-579-2999 E-MAIL : [email protected] Turbine Flow Meter Required Lengths of Straight Runs Flow altering device such as elbows, valves and reducers can affect accuracy. See diagram below for typical flow meter system installation. Diagram 1. Typical Flow Meter System Installation The recommended guidelines are given to enhance accuracy and maximize performance. Distance given here are minimum requirements; double them for desired straight pipe lengths. ◾ Upstream: allow a minimum straight pipe length at least 10 times the internal diameter of the pipe. For example, with the 50mmpipe, there should be 500mm of straight pipe immediately upstream. Desired upstream straight pipe length is 1000mm. ◾ Downstream: allow a minimum straight pipe length at least 5 times the internal diameter of the pipe. For example, with the 50mm pipe, there should be 250mm of straight pipe immediately upstream. Desired upstream straight pipe length is 500mm. 인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체 (주) 플 로 우 닉 스 - 18 - T E L : 82-32-579-2999 E-MAIL : [email protected] Turbine Flow Meter Special Notice ♦ Foreign material in the liquid being measured can clog the meter’s rotor and adversely affect accuracy. If this problem is anticipated or experienced, install screens to filter impurities from incoming liquids. ♦ To ensure accurate measurement, drain all air from the system before use. ♦ When the meter contains removable coverplates. Leave the coverplate installed unless accessory modules specify removal. Don’t remove the coverplates when the meter is powered, or electrical shock and explosion hazard can be caused. ■ Connections Thread Connection Note: Default Thread is Male G Thread, other thread are available on request. For example: Female NPT Thread, Male NPT Thread; Consult FLOWNICS for more information Diameter (mm) L (mm) Thread Criteria 25 170 G 2” 40 140 G 2” 50 150 G 2‐1/2” 인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체 (주) 플 로 우 닉 스 - 19 - T E L : 82-32-579-2999 E-MAIL : [email protected] Turbine Flow Meter Flange Connection ANSI Flange Meter Dimensions Size Code (inch) 1" A (mm) 170 10" (mm) 25 40 50 65 80 100 125 150 200 250 12" 300 300 1-1/2" 2" 2-1/2" 3" 4" 5" 6" 8" 200 200 240 240 300 240 450 500 500 ANSI Flange Rating Class Flange Diameter (B) Bolt Hole Diameter Bolt Circle Diameter (PCD) Bolt Hole Quantity 150 300 150 300 150 300 150 300 150 300 150 300 150 300 150 300 150 300 150 300 150 300 (mm) 108 124 127 155 152 165 180 190 191 210 229 254 255 280 279 318 343 381 460.4 444.5 482.6 520.7 (mm) 16 19 16 22 19 19 19 22 19 22 19 22 22 22 22 22 22 25 25 28.4 25.4 31.8 (mm) 79 89 99 114 121 127 140 149 152 168 191 200 216 235 241 270 298 330 362 387.3 431.8 450.9 4 4 4 4 4 8 4 8 4 8 8 8 8 8 8 12 8 12 12 16 12 16 인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체 (주) 플 로 우 닉 스 - 20 - T E L : 82-32-579-2999 E-MAIL : [email protected] Turbine Flow Meter DIN Flange Meter Dimensions Size Code A DIN Flange Pressure Rating Flange Diameter (B) Bolt Hole Diameter Bolt Circle Diameter (PCD) Bolt Hole Quantity (inch) (mm) (mm) MPa (mm) (mm) (mm) 1" 25 170 1.6 115 14 85 4 1-1/2" 40 200 1.6 150 18 110 4 2" 50 200 1.6 165 18 125 4 2-1/2" 65 240 1.6 185 18 145 4 3" 80 240 1.6 200 18 160 8 4" 100 300 1.6 220 18 180 8 5" 125 240 1.6 250 18 210 8 6" 150 450 1.6 285 22 240 8 8" 200 500 1.6 340 22 295 12 10" 250 500 1.6 405 26 355 12 12" 300 300 1.6 460 26 410 12 인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체 (주) 플 로 우 닉 스 - 21 - T E L : 82-32-579-2999 E-MAIL : [email protected]
© Copyright 2025 ExpyDoc