Turbine Flow Meter KOTGQ SERIES [Temperature and Pressure

Turbine Flow Meter
KOTGQ SERIES [Temperature and Pressure Compensation]
KOTQ Series는 온도와 압력 보상이 가능한 가스
터빈 유량계입니다.
Temperature
and
Pressure
compensation,
normative flow can be displayed .
■ Technical Data
Measuring system Gas: Natural Gas, LPG, Air
(1) Dry gas without water
(2) Gas without corrosion
Application range Measured Value
Primary measured value Secondary measured value Tertiary measured value
Flow Rate
Volume flow Temperature; Pressure (ONLY available for compensation model)
Design Features Modular construction The measurement system consists of a flow sensor and a signal converter. It is available as compact and as separate version. Compact version converter
Compensation Type
D1: Local Display; 24V DC Power; Dual Power: Battery;4‐20mAOutput(3‐wire);SIRERS485
D2: Local Display: 24V DC Power; Dual Power: Battery;4‐20mAOutput(2‐wire);ModbusRS485
Connection
Thread: DN25‐DN50
Flange: DN25‐DN300 (DIN, ANSI, JIS)
Measurement Ratio
Standard – 10:1; Optional: 20:1
인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체
(주) 플 로 우 닉 스
- 14 -
T E L
: 82-32-579-2999
E-MAIL : [email protected]
Turbine Flow Meter
Measuring accuracy Reference conditions Flow Meter Accuracy
Flow conditions similar to ISO 9951
Medium: Gas
Temperature: +10...+30°C / +50...+86°F Inlet section: ≥ 10 DN Operating pressure: 1 bar / 14.5 psig Standard: 1.5%
Qmin to 0.2Qmax: 3%; 0.2Qmax to Qmax: 1.5%
Optional: 1.0% Qmin to 0.2Qmax: 2%; 0.2Qmax to Qmax: 1.0%
Operating conditions Temperature
Process temperature Ambient temperature
(all versions) Storage temperature Pressure
EN 1092‐1 ASME B16.5 JIS ‐20...+80°C Standard (with aluminum converter housing): ‐10…+55°C ‐20...+70°
DN25…DN300: PN 16 Other pressures on request 1”...12": 150 lb RF Other pressures on request 1”...12": 10 K Other pressures on request Installation conditions Installation
For detailed information see chapter "Cautions for Installation" Flow direction Forward
Arrow on flow sensor indicates flow direction. Inlet run Outlet run ≥ 10 DN ≥ 5 DN Materials Sensor housing Flanges Rotor
Bearings and Shaft
Converter Housing
SS304
Other materials on request SS304
Other materials on request ABS Plastic (Acrylonitrile ‐ Butadiene – Styrene)
Aluminum Alloy
SS304
Standard: polyurethane coated die‐cast aluminum 인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체
(주) 플 로 우 닉 스
- 15 -
T E L
: 82-32-579-2999
E-MAIL : [email protected]
Turbine Flow Meter
■ Model and Selection
Table 1: Model Selection Guidance for Gas Turbine Flowmeter
Model Suffix Code
Description
KOTGQ‐
Local display; 24V DC and Battery Power; 3‐wire 4‐20mA Output
SURE RS485 Protocol
Local display; 24V DC and Battery Power; 2‐wire 4‐20mA Output
Modbus RS485 Communication
D1‐
Converter
D2‐
Diameter
Three Digitals; for example:
025: 25 mm; 050: 50 mm;
125: 125 mm; 300: 300 mm XXX
Flow range
S(x)
W(x)
S
L
Body Material
Rotor Material
Explosion Level
S
L
N
E1
E2
‐DXX
Connection
‐AX
‐JX
‐TH
Accuracy
‐N
‐G1
Refer to flow range table
Refer to flow range table
SS304
Cast Aluminum
ABS Plastic
Aluminum Alloy
Safety Field without Explosion
ExiaIICT4
ExdIIBT6
DXX: D06, D10, D16, D25, D40
D06: DIN PN6; D10: DIN PN10
D16: DIN PN16; D25: DIN PN25
D40: DIN PN40
AX: A1, A3, A6
A1: ANSI 150#; A3: ANSI 300#
A6: ANSI 600#
JX: J1, J2, J4
J1: JIS 10K; J2: JIS 20K; J4: JIS 40K
Thread; DN4…DN50
1.5%
1.0%
Model Code: LWQ‐D1‐100S1SLN‐D16‐N
Explanation ‐ Converter: battery power mode without output; Diameter: 100mm; Flow range: 20‐400 m3/h; Body Material: SS304; Rotor Material: Aluminum Alloy; No Explosion; Connection: DIN PN16 Flange; Accuracy: 1.5% 인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체
(주) 플 로 우 닉 스
- 16 -
T E L
: 82-32-579-2999
E-MAIL : [email protected]
Turbine Flow Meter
Measurable Flow Rate Range: Note: The flow range as blow is based on operating status; REFERENCE ONLY. Consult the factory if you have special requirement. Refer to the nameplate or certificate for actual flow range.
Nominal Diameter
(mm)
(in.)
Standard Flow Range (SFR) Code
(m3/h)
Standard Pressure Rating
(MPa)
Extended Flow Range (EFR)
Code
(m3/h) 25
1
S
2.5 to 25
W
4 to 40
40
1.5
S
5 to 50
W
6 to 60
50
2
S1
S2
6 to 65
10 to 100
W1
W2
5 to 70
8 to 100
65
2.5
S
15 to 200
W
10 to 200
80
3
10 to 160
4
15 to 300
20 to 400
20 to 400
32 to 650
W
100
S1
S2
S1
S2
W
13 to 250
125
5
S
25 to 700
W
20 to 800
150
6
80 to 1600
8
W
50 to 1000
250
10
32 to 650
50 to 1000
80 to 1600
130 to 2500
130 to 2500
200 to 4000
W
200
S1
S2
S1
S2
S1
S2
W
80 to 1600
300
12
S
200 to 4000
W1
W2
130 to 2500
320 to 6500
400
16
S
400 to 8000
W
260 to 8000
1.6
■ Cautions for Installation
Mounting Positions
Avoid all pipe locations where the flow is pulsating, such as in the outlet side of piston or diaphragm pumps.
Avoid locations near equipment producing electrical interference such as electric motors, transformers, variable frequency, etc.
Install the meter with enough room for future access for maintenance purposes.
Warning: Precaution for direct sunshine and rain when the meter is installed outside.
인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체
(주) 플 로 우 닉 스
- 17 -
T E L
: 82-32-579-2999
E-MAIL : [email protected]
Turbine Flow Meter
Required Lengths of Straight Runs
Flow altering device such as elbows, valves and reducers can affect accuracy. See diagram below for typical flow meter system installation.
Diagram 1. Typical Flow Meter System Installation
The recommended guidelines are given to enhance accuracy and maximize performance. Distance given here are minimum requirements; double them for desired straight pipe lengths.
◾ Upstream: allow a minimum straight pipe length at least 10 times the internal diameter of the pipe. For example, with the 50mmpipe, there should be 500mm of straight pipe immediately upstream. Desired upstream straight pipe length is 1000mm.
◾ Downstream: allow a minimum straight pipe length at least 5 times the internal diameter of the pipe. For example, with the 50mm pipe, there should be 250mm of straight pipe immediately upstream. Desired upstream straight pipe length is 500mm.
인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체
(주) 플 로 우 닉 스
- 18 -
T E L
: 82-32-579-2999
E-MAIL : [email protected]
Turbine Flow Meter
Special Notice
♦
Foreign material in the liquid being measured can clog the meter’s rotor and adversely affect accuracy. If this problem is anticipated or experienced, install screens to filter impurities from incoming liquids.
♦
To ensure accurate measurement, drain all air from the system before use.
♦
When the meter contains removable coverplates. Leave the coverplate installed unless accessory modules specify removal. Don’t remove the coverplates when the meter is powered, or electrical shock and explosion hazard can be caused.
■ Connections
Thread Connection
Note: Default Thread is Male G Thread, other thread are available on request. For example: Female NPT Thread, Male NPT Thread; Consult FLOWNICS for more information
Diameter (mm)
L (mm)
Thread Criteria
25
170
G 2”
40
140
G 2”
50
150
G 2‐1/2”
인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체
(주) 플 로 우 닉 스
- 19 -
T E L
: 82-32-579-2999
E-MAIL : [email protected]
Turbine Flow Meter
Flange Connection
ANSI Flange Meter Dimensions
Size Code
(inch)
1"
A
(mm)
170
10"
(mm)
25
40
50
65
80
100
125
150
200
250
12"
300
300
1-1/2"
2"
2-1/2"
3"
4"
5"
6"
8"
200
200
240
240
300
240
450
500
500
ANSI Flange
Rating Class
Flange
Diameter
(B)
Bolt Hole
Diameter
Bolt Circle
Diameter
(PCD)
Bolt Hole
Quantity
150
300
150
300
150
300
150
300
150
300
150
300
150
300
150
300
150
300
150
300
150
300
(mm)
108
124
127
155
152
165
180 190 191
210
229
254
255 280 279
318
343
381
460.4
444.5
482.6
520.7
(mm)
16
19
16
22
19
19
19 22 19
22
19
22
22 22 22
22
22
25
25
28.4
25.4
31.8
(mm)
79
89
99
114
121
127
140 149
152
168
191
200
216 235 241
270
298
330
362
387.3
431.8
450.9
4
4
4
4
4
8
4 8 4
8
8
8
8 8 8
12
8
12
12
16
12
16
인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체
(주) 플 로 우 닉 스
- 20 -
T E L
: 82-32-579-2999
E-MAIL : [email protected]
Turbine Flow Meter
DIN Flange Meter Dimensions
Size Code
A
DIN Flange
Pressure
Rating
Flange
Diameter
(B)
Bolt Hole
Diameter
Bolt Circle
Diameter
(PCD)
Bolt Hole
Quantity
(inch)
(mm)
(mm)
MPa
(mm)
(mm)
(mm)
1"
25
170
1.6
115
14
85
4
1-1/2"
40
200
1.6
150
18
110
4
2"
50
200
1.6
165
18
125
4
2-1/2"
65
240
1.6
185
18
145
4
3"
80
240
1.6
200
18
160
8
4"
100
300
1.6
220
18
180
8
5"
125
240
1.6
250
18
210
8
6"
150
450
1.6
285
22
240
8
8"
200
500
1.6
340
22
295
12
10"
250
500
1.6
405
26
355
12
12"
300
300
1.6
460
26
410
12
인천비전기업 / 인천유망중소기업 / 한국남부발전 정비적격업체
(주) 플 로 우 닉 스
- 21 -