DET NORSKE VERITAS - kabel

DET NORSKE VERITAS
TYPE APPROVAL CERTIFICATE
CERTIFICATE NO. E-13038
This is to certify that the
Data transmission cables and systems
with type designation(s)
MI-VHH 2G 62,5/125 3,1B200 +0,8F600 + 2x1 Cu
Issued to
Prysmian Kabel und Systeme GmbH
Neustadt b. Coburg, Germany
is found to comply with
Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore
Standards
IEC 60092-376 (2003-05)
IEC 60332-3-22 (2009-02)
IEC 60754-1/2 (2011-11)
IEC61034-1/2 (2005-04/2005-04)
IEC 60794-1-1
Application
Hybrid fiber opictal/Cu pair cable
Voltage (kV)
Temp. class (°C)
0,25
80
This Certificate is valid until 2017-12-31.
Issued at Høvik on 2014-02-07
for Det Norske Veritas AS
DNV local station: Essen CMC Southern Germany
Digitally Signed By: Laumann, Marit
Location: DNV Høvik, Norway
Approval Engineer: Marta Alonso Pontes
Signing Date: 2014-02-12
Marit Laumann
Head of Section
This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid.
The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed.
If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such
person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum
compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers,
employees, agents and any other acting on behalf of Det Norske Veritas.
DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Org.No. NO 945 748 931 MVA.
Form No.: TA 1411a Issue: 2013-10
www.dnv.com
Page 1 of 3
Certificate No.: E-13038
827.50
File No.:
Job Id.:
262.1-008096-3
Product description
Type:
MI-VHH 2G 62,5/125 3,1B200/0,8 F600 + 2x1 Cu
Conductor:
Core insulation:
Plain stranded copper
EPR
Fibre types:
Core diameter:
Cladding diameter:
Coating diameter:
Attenuation:
850 nm
1300 nm
Multi-mode 62,5/125
62,5 ± 3,0 mm
125 ± 2,0 mm
245 ± 10 mm
max 3,1 dB/km
max 0,8 dB/km
Bandwidth:
850 nm
1300 nm
Numerical aperture:
min 200 MHz×km
min 600 MHz×km
0,275 ± 0,015
Metal covering:
Sheath:
Braid copper wires
SHF1
Number of cores x conductor
cross-section
2
2x1,0 mm + 62,5/125mm
Overall dimensions
13,3 ± 0,5mm
Application/Limitation
Temperature window
Operation:
Storage:
-20°C to +80°C
-40°C to +80°C
The requirements of SOLAS Amendments Chapter II-1, Part D, Reg. 45, 5.2 (provision to be taken to limit Fire Propagation
along Bunches of Cables or Wires) are fulfilled without any additional measures.
Type Approval documentation
Constructional details no.: 3193 dated 1997-06-27
Data sheet LSZH30-01-XXY and OPSTD-TT-62P.
Optical Fiber specification from SpecTran dated 3/97
Produktspezifikation no.: 50 PS 117 dated 1997-07-17.
Test report No. 2001/2201 from “Wolf Kabeltechnik GmbH” dated 2001-12-17 and 5BG6960 dated 2000-04-04.
Test report 50 PS 117 dated 2013-12-09
Technical datasheet SIENOPYR-FR MI_VHH 2G62,5 Dated 2008-08-19
Tests carried out
Standard
IEC 60092-376
Release
2003-05
IEC 60332-3-22
2009-02
IEC 60754-1
2011-11
General description
Cables for control and instrumentation circuits
150/250 V (300 V)
Tests on electric and optical fibre cables under
fire conditions – Part 3-22: Test for vertical flame
spread of vertically-mounted bunched wires or
cables – Category A
Test on gases evolved during combustion of
materials from cables - Part 1: Determination of
the halogen acid gas content
Limitation
Bunch test
Category A
Low Halogen:
<0,5% Halogen
DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Org.No. NO 945 748 931 MVA.
Form No.: TA 1411a Issue: 2013-10
www.dnv.com
Page 2 of 3
Certificate No.: E-13038
827.50
File No.:
Job Id.:
262.1-008096-3
Standard
IEC 60754-2
Release
2011-11
IEC 61034-1/2
2005-04
IEC 60794-1-1
2001-07
General description
Test on gases evolved during combustion of
materials from cables - Part 2: Determination of
acidity (by pH measurement) and conductivity
Measurement of smoke density of cables
burning under defined conditions –
Test apparatus, procedure and requirements
Optical fibre cables – Part 1-1: Generic
specification – General
Limitation
Halogen free:
pH > 4,3
Conductivity < 10μS/mm
Light transmittance > 60%
Marking of product
♦ SIENOPYR - MI-VHH 2G 62,5/125 3,1B200 +0,8F600 + 2x1 Cu 300 V
Periodical assessment
The scope of the periodical assessment is to verify that the conditions stipulated for the Type approval is complied with and that
no alterations are made to the product design or choice of materials.
The main elements of the periodical assessment are:
·
Inspection on factory samples, selected at random from the production line (where practicable)
Results from Production Sample Tests (PST) and Routines (RT) checked (if not available tests according to PST and RT to
·
be carried out)
·
Review of type approval documentation
·
Review of possible change in design, materials and performance
Ensuring traceability between manufacturer’s product type marking and Type Approval Certificate.
·
Periodical assessment shall be performed at least every second year.
END OF CERTIFICATE
DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Org.No. NO 945 748 931 MVA.
Form No.: TA 1411a Issue: 2013-10
www.dnv.com
Page 3 of 3