DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-13038 This is to certify that the Data transmission cables and systems with type designation(s) MI-VHH 2G 62,5/125 3,1B200 +0,8F600 + 2x1 Cu Issued to Prysmian Kabel und Systeme GmbH Neustadt b. Coburg, Germany is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards IEC 60092-376 (2003-05) IEC 60332-3-22 (2009-02) IEC 60754-1/2 (2011-11) IEC61034-1/2 (2005-04/2005-04) IEC 60794-1-1 Application Hybrid fiber opictal/Cu pair cable Voltage (kV) Temp. class (°C) 0,25 80 This Certificate is valid until 2017-12-31. Issued at Høvik on 2014-02-07 for Det Norske Veritas AS DNV local station: Essen CMC Southern Germany Digitally Signed By: Laumann, Marit Location: DNV Høvik, Norway Approval Engineer: Marta Alonso Pontes Signing Date: 2014-02-12 Marit Laumann Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas. DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Org.No. NO 945 748 931 MVA. Form No.: TA 1411a Issue: 2013-10 www.dnv.com Page 1 of 3 Certificate No.: E-13038 827.50 File No.: Job Id.: 262.1-008096-3 Product description Type: MI-VHH 2G 62,5/125 3,1B200/0,8 F600 + 2x1 Cu Conductor: Core insulation: Plain stranded copper EPR Fibre types: Core diameter: Cladding diameter: Coating diameter: Attenuation: 850 nm 1300 nm Multi-mode 62,5/125 62,5 ± 3,0 mm 125 ± 2,0 mm 245 ± 10 mm max 3,1 dB/km max 0,8 dB/km Bandwidth: 850 nm 1300 nm Numerical aperture: min 200 MHz×km min 600 MHz×km 0,275 ± 0,015 Metal covering: Sheath: Braid copper wires SHF1 Number of cores x conductor cross-section 2 2x1,0 mm + 62,5/125mm Overall dimensions 13,3 ± 0,5mm Application/Limitation Temperature window Operation: Storage: -20°C to +80°C -40°C to +80°C The requirements of SOLAS Amendments Chapter II-1, Part D, Reg. 45, 5.2 (provision to be taken to limit Fire Propagation along Bunches of Cables or Wires) are fulfilled without any additional measures. Type Approval documentation Constructional details no.: 3193 dated 1997-06-27 Data sheet LSZH30-01-XXY and OPSTD-TT-62P. Optical Fiber specification from SpecTran dated 3/97 Produktspezifikation no.: 50 PS 117 dated 1997-07-17. Test report No. 2001/2201 from “Wolf Kabeltechnik GmbH” dated 2001-12-17 and 5BG6960 dated 2000-04-04. Test report 50 PS 117 dated 2013-12-09 Technical datasheet SIENOPYR-FR MI_VHH 2G62,5 Dated 2008-08-19 Tests carried out Standard IEC 60092-376 Release 2003-05 IEC 60332-3-22 2009-02 IEC 60754-1 2011-11 General description Cables for control and instrumentation circuits 150/250 V (300 V) Tests on electric and optical fibre cables under fire conditions – Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category A Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content Limitation Bunch test Category A Low Halogen: <0,5% Halogen DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Org.No. NO 945 748 931 MVA. Form No.: TA 1411a Issue: 2013-10 www.dnv.com Page 2 of 3 Certificate No.: E-13038 827.50 File No.: Job Id.: 262.1-008096-3 Standard IEC 60754-2 Release 2011-11 IEC 61034-1/2 2005-04 IEC 60794-1-1 2001-07 General description Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity Measurement of smoke density of cables burning under defined conditions – Test apparatus, procedure and requirements Optical fibre cables – Part 1-1: Generic specification – General Limitation Halogen free: pH > 4,3 Conductivity < 10μS/mm Light transmittance > 60% Marking of product ♦ SIENOPYR - MI-VHH 2G 62,5/125 3,1B200 +0,8F600 + 2x1 Cu 300 V Periodical assessment The scope of the periodical assessment is to verify that the conditions stipulated for the Type approval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the periodical assessment are: · Inspection on factory samples, selected at random from the production line (where practicable) Results from Production Sample Tests (PST) and Routines (RT) checked (if not available tests according to PST and RT to · be carried out) · Review of type approval documentation · Review of possible change in design, materials and performance Ensuring traceability between manufacturer’s product type marking and Type Approval Certificate. · Periodical assessment shall be performed at least every second year. END OF CERTIFICATE DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Org.No. NO 945 748 931 MVA. Form No.: TA 1411a Issue: 2013-10 www.dnv.com Page 3 of 3
© Copyright 2024 ExpyDoc