RDSO/PE/SPEC/D/ACI0181-2014 (Rev-"O") . 0\ ? ~~ GOVERNMENT 0 DIA MINISTRY OERAILWAYS RESEARCH DESIGN§e.ND STAN!2ARL>S ORGANISATION MINISTR'6' OF RAIEWAYS TECHNICAL SPECIFICATION FOR EMERGENC'6' LIGHT UNIT (SAFETY LIGHT UNIT - SLU) FOR EOG COACHES OF INDIAN RAILWA '6' ctil4ctil'~~ EO/PS &EMU /-qr ~ ~ t ~ 1! Page No. 3 Training Infri elll~pt of patent rigQJ e engineers Warranty 15 16 16 16 17 Testing for checking the working of SLU in the coach 16 18 Enclosure Annexure A Performa forurigertaking Annexure B Sample wav¢fprm of power supply in coach 18-20 Annexure C Temperafurecycle 21 Annexure D Sketch for name plate for Indication LED Distribution list 16 against cartel formation for Burn in test 17 22 23 The general lighting inside the coaches is provided by 24 V DC or 110V dc supply in EGG coaches. The supply system is backed up by battery system of 11OV DC /24 V DC for End on generation type coaches. During extreme emergencies like derailment and accidents etc. sometimes these supply system fail, causing total darkness inside the coach. To facilitate easy exist of passenger and their immediate rescue during such emergencies, this Emergency Light unit (safety light unit-SLU) has been developed to provide illumination during failure of all other power supplies inside the coach. These emergency light Units (SLU) are provided inside the coach and on doorways, would switch 'on' automatically in the event of failure of normal supply system110 V DC & 24 V DC. Hence reliability of Emergency Light unit (SLU) is of paramount importance. 2.1 The specification covers general guidelines fpr design, man~facture, service of Emergency Light unit (SLU) for type coaches. 2.2 The emergency light should switch 'on'automatically in case normatbattery the coach 110 V DC and 24 DC fail during any unforeseen circumstanc~s. 2.3 When the normal supply fails, the Emergency illumination, as stipulated in c1au$~.6.15. Ei'rlP Li~ht unit (SLU) tests, supply and sales supply system of shall deliver required Quantity per coach (Safety ligh~~pit-SLU ) for EGG type capacity sealed maintenance free 4 No. Firm shall e copy of op§!ration & maintenance cum trouble shooting manual with supplylot up to For su~~!y lot above 100 units, one copy of operation & maintenance cum trouble shootll"l9.manual for every 100 units will be supplied. j~i" The equipment shall be sturdy and suitable for the following service conditions be met in service: i) Ambient -5 to +55 deg Celsius ii) Train speed 200 Kmph iii) Relative Humidity Up to 98% during rainy season iv) Altitude Max 1200 meter above sea level Prepared By Checked By normally to Extremely dusty, foggy, and desert terrain in certain areas. The dust concentration in air may reach at high value of 1.6mglcubic meter Very heavy in certain areas. The equipment shall be designed to work in humid salt laden and corrosive atmosphere .The maximum values of the condition shall be as under: Maximum Ph value Sulphate Max concentration Max. conductivity The equipment, system their~:punting designed to with nd satisfactorily the encountered in as specified below: (a) Maximum vertigi-'l'acceleration (b) Maximum lateraLi'lCC!3leration (c) Maximum longitudinq!acceleration arrangement shall be vibration and shocks : 3.0 g, : 3.0 g. : 5.0 g. 6.0 TECHNICAL 6.1 The input power to the Emergency Ught unit (SLU)is 110 V OC+I- 30% or 24 V DC in case of LHB EO coaches. . REQUIREMENTS The supply. 6.3 Each 7 Ah Amar shall emergency unit will contain Sealed Lead Acid Maintenance Free type (SMF) Battery of capacity. The battery shall be 12 Volt, 7 Ah of Mis Exide I Mis TAFE (AMCO) I Mis Rajal Mis HBL make .The battery older than six months from date of manufactured not be used. 6.4 The battery shall be purchased from OEMs only. Purchase certificate enclosed along with the emergency light unit. 6.5 The battery of emergency light unit (SLU) should be driven by Microprocessor and voltage controller for duster of LEOs. from OEM shall be based current i. The Emergency Light unit (SLU) shall consists of battery backup system, control circuit for charging the battery, sensing the battery charging current, voltage etc, and trip or cut off circuit for the unit to avoid over charging/deep discharge and give a visual indication. ii. The battery shall be charged at 13.5V +/- 0.1Volts in floating mode and 14.4V +/0.1 Volts in boost mode depending on the state of the battery. The control circuit should be very specific in terms of boost and trickle charging characteristic. iii. The emergency light unit (SLU) shall stop workip~ as soon as the battery voltage reduces to 10.5Volts, to prevent deep discharg€lof the battery in order to keep the battery in healthy condition. The battery supply shall be available up to 9 Volts battery voltages to show the status of igdiC<;iti LED (Amber flashing) for deep discharge of battery below 10.5 volts a~!p~r cia o. 6.6 of this specification. Whenever the battery voltage redu 14.4V +/- 0.1V with current limit a the terminal voltage of the batt switched over to trickle charge v. The system should embedded software version. The software the name of any indivi engineers. attery shall be charged at 10.5 Volts, t ttery manufacturer. After mmended by t the charging shall be charge reaches 14.4 13.5V +/- 0.1 Volts. ogic component i.e. ICs'iiduly burnt with he software shall be of original licensed name of the manufacturer and not in p software within firm by software The following the coach. Parameter Unit Battery conne¢tion intact Green LED ON Unit Battery discharging @ 20% Failure of 11OVd Unit Battery 4nhealthy replacement The LEOs shall be similar to the following types and make or equivalent type and other make with prior approval of ROSO:- Colour of indication LED Nichia make Seoul semiconduct or make Avago make Cree make Green NSPG 500 S LT620 Green 525 mm Lamp CB series, HLMP-CM series Red 626 HLMPEG08- series C503B- series Red Amber NSPR 510AS NSPY500 LR 530A S LY520A The equivalent indication approval of ROSa. Amber 590HLMP H08 series C503B- series C503B- series LED of above or other 6.7 The control circuit of the Emergency Light unitCS£. shallbegesigned in such a way that the current drawn by LEOs shall be minimized give maximumiguration of lighting. The actual current drawn by LEOs shall be such t drawn from the batt~ry shall not exceed 4 AH for new emergency light unit. However t pensate the temperatyfe pnd aging factor of the battery, the battery used shall be of 7AHQ~pacity, so that the emergency light will work at least 12 hours during the life of the battery asp~r Lux re uirement stated indause 6.15. 6.8 The manufacturer shall sUb~ittn~calculations sh~~! ... he actual AH drawntrom during the type test/revalidatio~,fype t~Rt/ prototypelesf. 6.9 There should be a provision for e of battery>by 20% of its rated capacity to a maximum time of 4/5 hours auto trol circuit pt a regular interval of 15 days to improve the life e battery. !Q¥batteryshall be carried out by using either resistance nic meth t s ifchi~~ 'on' LEOs. This discharge shall be done during'fl1e day tim 9n'Y from to 12.00 P.M, so that it can be recharged during the re 'ng periodi!~{ the day an ready for use during night in case of emergency situations. If the ch batt~ryf~ils during sYHr discharge, the emergency light should switch mode fgr readinessa~. per the requirement stated in clause 6.15. X:,:, ",,:"':':: the battery ....«;,;,;,,'~ 6.10 current drawn fromth~unit batteryiniglecondition shall be minimum and designed in a way that treunitbqtt~ry will notgo below 10.5V even after 6 months of storage use. Firm willsybmit und~rtaking in this regard. 6.11 Theehlergency unit sh0919 switchlOh' automatically when supply voltage drops to 80 V DC or below IN connected with 110 V DC supply. 6.12 In case the riiiQ~~proce~S9r of the unit fails, the emergency light unit (SLU) shall work as normal during e~)~~~ency situations. The necessary hardware back up arrangements shall be incorporated in tfie>design of the unit. This will be tested during Proto-type test/revalidation type test by removing microprocessor from unit under test. After taking out the processor the unit should keep on functioning as under: a) b) c) 6.13 Trickle charging mode should work ON/OFF as per Para 6.11 Lux level at 20 Lux for 12 hrs with 7 AH battery. The microprocessor should have an auto reset facility through a separate watch dog / supervisor circuit. In case the microprocessor is stuck due to EMI, surges or spikes or software stuck fault, it should be able to restart by the separate hardware watch dog / supervisor circuit. The power supply circuit of the Emergency Light unit (SLU) should have a provision of auto reset in case of the following faults. a)Power b)Power c)Stuck d) Input 6.14 supply output over current fault supply short circuit fault against transient & surge fault over voltage fault (over 200 volts) The LED shall be arranged in three clusters as shown in the RDSO drawing no. RDSO/PE/SKIAC/0181-2014( Rev-"O"). Left and right cluster each will have 12 nos. LED and Middle cluster will have 30 nos. LED , which will Lux requirement stipulated in clause 6.15 Not less than 250 Lux at 0.5M Not less than 100 Lux aL1:0M with fully charged battery Not less than 30 Lux at 2.1iM for the first 2 hours starting with the Not less than 20 Lux at 2.1 M for further 1 rs The above values are measu cluster of LEDs and when all the the battery vol tag . shall be ke maintained up JOb 'tpltage of 1 6.16 ace perpenqic::ular to the light rays from middle ON conditiOn. At the start of illumination test, volts and Lux level as above shall be The Super Bri ht White hi~.R!ntensity L s.shall be from any one of the following OEMs as per type menti meet!If:j~ Lux requirerjlent as per Para 6.15 : PartIhb. of LED N§SWl56T-P3 or equivalent to above DO~IS E3 LUWJNSH.EC BRBT/BSBU to above. HW331 A or equivalent to above or equivalent Any other make or er equivalent part no of above make meeting the parameters of specification may be used with prior approval of RDSO. (1) (2) (3) (4) (5) It shall be Super Bright White high intensity and Industrial grade type. Minimum luminous efficiency = 100 ImlW at 25°C. Life time (L70) = minimum 50000 hrs at TJ=70 DC. View angle = Minimum 100 Colour temperature = 50oo-7000K 0 (6) 1) 2) 3) 4) 5) 6) Luminous flux of LED bin shall be minimum 7 lumens at 30 mA at Ta = 25 degree C . OEMs certificate for purchase of LED. Test certificate of LED by OEM. Data sheets of LED. Reliability test data sheet of LED. Label details on packing: part no. , lot no. , ranking by colour coordinate, luminous flux. Junction temperature calculation of LED. ranking by 6.18 The Emergency Light unit (SLU) will be fitted on t~e r90f eiling / partition wall of the coach. The battery portion of the light fitting will be con~~led a Iy LED portion of the light fitting will be projecting outside. Hence selection q~!!!:!::paHery an Its housing shall be suitable flat arrangement such that leakage of battery s~al!iJ~bt be occurred battery should be fitted in such a way that it can be easily replaced I:>yralrway person. 6.19 The Industrial grade electronic component~iL'l~ed shall be as per the following: 6.20 d) The resist loading vrp e) Switching devices such as temperature of 150°C. t) The devices shall g) The fire retaro~nt FR-4 grade glass epoxy coated PCB shall be used. The protectivecum-adhesive cqating used oJ) PCBs should be clear and transparent and should not affrpct color code ofrp!rpctronic component or the product code of the component. h) The heavy componrpht§ should be properly fixed. with gooq ~nish. i) The electronic cii~~.~it§,PCB and components should also meet the RDSO Spec. No. ELRS/SPEC/Sl!0015 - OCT.2001 (Rev.1) Specification for Reliability of Electronics used in rolling stock application. j) The electronics covered for this equipment shall pass all the tests called for in the above specification. s shall be preferably ma rating shall be 3. The shoulder connection should be No electro-mechanical components shall be used. All the control systems, Electronic circuits, Relays, Cut-off systems, etc., to ensure automatic operation of emergency lights should be necessarily Solid state type only. Prepared By ~ 6.21 The health of the unit battery during 20% discharge cycle. discharge rate shall mean that indicated by Red LED flashing shall be monitored using dv/dt characteristics of the battery Any abnormality in dv/dt from its reference value at 20% the battery is unhealthy and needs replacement. This shall be which shall continue till the battery is replaced. 6.22 Emergency Light unit (SLU) shall be designed with SMPS working on 90 Volts dc to 143 V dc power supply . 6.23 Emergency Light unit (SLU) shall be designed with battery mounted on PCB for back up to Real time clock (RTC) 7.1 The complete emergency unit will be of compa design with mounting dimensions and overall dimension as per the enclosed ROSa dr no. ROSa/PE/SKlAC/0181-2014(Rev"O")(Sheet 1 and Sheet2) . Antitheft arrangementsha I be as§Qown in sheet 2 of this drawing. The housing with the hinged cover assem all be of robUst and reliable construction. The housing shall be deep drawn from 0.8 k CRCA sheet to IS 513-94, Grade DO. The hinges should not be visible from outsi 7.2 The hardware shall confirm to IS 1364 - 92 "Specification for hexagonal head bolt, screws and nuts". The minimum size of the hardware shcillp¢!.M5!and the hexagonalhead slotted screw shall work on tapped frame arr ent. The enclosure of the unit shall co deep drawn from 0.8 mm thick CR A frame shall be secured properly to for of the unit shall be provided on both si The enclosure snaUQe po colour of M/s. BURGER snad e and bottom frame and these shall be grade DO. The top and bottom ~••Incl ure! ••• ~ nos. holes of 6 mm size for cooling {enclosure for cooling of battery. g1~:94 to a minimum thickness of 60 microns to Broken White 302 or equivalent with prior approval of ROSa. 7.6 THe 7.7 The size of the fixing screws with I nut / washer shall be M5 hexagonal head with slot head whereve d for the as§embly inside the unit. 7.8 Other enclosut~§pf the unit shall be fixed to the member channel arrangement with provision for easy removaI:i:ihg att$nding to the battery, PCB etc 7.10 Fire retardant Transparent V-O grade UL-94 polycarbonate sheet of thickness 0.75mm to 1.5 mm shall be provided for protection of LED from external damage and ingress of dirt. 7.11 Terminals with terminal designation of Wago type 261-102 shall be provided on the top hood for 110 Volts dc with blue and for 24 Volts DC with Parrot green female connector. 7.12 An automotive type connector to be provided inside the unit and one part to be fixed rigidly for connection/disconnection of unit battery to the circuit. battery sh~II<~e fixed!Q:ide the unitg~~perly to avoid movement in vertical as well as hprizontal diredion ..and taKing. care of the vibration encountered in service. The battery mounting shall be sUitable for ahdirection. 7.13 Fire retardant V-O grade UL-94 compliant White colour specification IS 1719 - 88 to be glued all around the fitting. 7.14 Dome key type captive screw to be provided for fixing the cover. One number dome key per four nos. emergency light units will be supplied. 7.15 The weight of complete maximum. 8.1.1 Only after the detail drawings and the design hav~ approved and the clearance given to this effect, the manufacturer shall take up tht;man acture q'~he prototype. It is to be clearly understood that any changes, required t~c~r done in the prototype or any additional tests other than specified herein are require(jYi~o be conducted on the prototype unit or its components, they shall be done expeditiously. 8.1.2 Subject to agreement between user and IllqQufacturt;r!yROSO shall repl(atsome or all type tests once in three years on sqmple basis, so a.s to confirm the quality of thgproduct to meet the specified requirements. 8.1.3 The type tests shall be carried'04tby in part under the following condi . a) b) c) d) e) assembly of Emergency soft wool felt 3 mm thick to Light unit (SLU) shall be 4.5 kilo gram represent~~.iMl( on prototype unit either totally or o!Jllil,Qy additional cost: A manufacturer undertakes to ma ture for the first time. An important change in design detai achines has been introduced. Specification is modified necessitating esigning of equipment. Unsatisfactory performance reported from user Railways. Resumption of production after an interruption of more than two years. 8.1.4 Investigation tests are intended to obtain additional information regarding the performance of the production. They shall be specially requested either by the user or by the manufacturer. 8.1.5 ROSa may conduct surprise check on manufacturing process and quality control along with any of the tests to ensure quality of product and its conformance to ROSa. 8.1.6 The tests Shall be carrie(j 94t at the works of the manufacturer in presence of Indian representative pn the prqtptype unit of the Emergency Light unit (SLU) as per governing sp~eificati modified or amplified. The manufacture shall have all necessary arrangelll or testing of Emergency Light unit (SLU). Tests for which are not available WI the firm shall be conducted at NABL accredited lab. 8.1.7 The test protocol indicating relevant clause of the test, condition of the test, specified value and observed value of the parameter for SLLJ shall be submitted by the firm before offering the sample for type testing. 8.1.8 The system shall successfully pass all the type tests for proving conformity with this specification. If anyone of the equipment fails in any of the type tests, the inspecting agency at his discretion, may call for another equipmenVcard(s) of the same type and subject it to all tests or the test(s) in which failure occurred. No failure shall be permitted in the repeat test(s). Railway relevant possible facilities Routine test are to be carried out on each unit to verify that properties & design of the product correspond to those measured during type test. Proper documentation of routine tests results should be available with the firm and should be produced before inspecting official on demand. Tests shall be conducted as per test schedule given. Each offered lot of supply shall be subjected to acceptance tests as per ROSa approved sampling plan or as per sampling plan spedfied in IS 2501, at manufacturer's works. Acceptance test shall be witnessed by inspecting offipial nominated by purchaser/ROSa. Manufadurer on demand by inspecting official shall.pnQcjuce the internal/routine test report carried out by manufacturer. S No. '/< " Test Type ..... Routin etest Accept ance test :<)j! .• 1) 2) 3) 4) Visual Test Checking of document battery Checking of document LEOs of of I~r~tse of purch~se<Qfl..J .... Ign docum ent « 9) 10) 11) 12) 13) 14) 15) 16) 17) Prepared Dielectric Test Insulation Test Reve[sePolaritv Test Performance ...test with 7 Ah battery Software burn- infest Tesf·.for battery pef(pCQ1ance ChecKing the functioning Microproq:lssor contrpll1i$r Mechanical Test Chromaticity and ..J ..J ..J ..J ~iii:h Electrical ,.~ > ..J ..J ..J "\ "\ ..J "\ ..J ..J "\ "\ ..J ..J "{ ," of. Endurance Performance test in case of Microprocessor failure Temperature rise test (Dry heat run test) Temperature rise test (Damp heat test) Vibration and Shunting Shock test As per approved bill of material during type test bv ROSa. 8.8 8.9 8.10 8.11,6.12,6.15 , x ..J x 8.12 8.13 To be 6.5,6.6,6.7 , 6.9, and conduc 6.10,6.13 ted for 6.15 6.12 a lot of As per 50 during type test Nos. only. x 8.14 ..J x x ..J x x As per approved LED datasheet bv ROSa. 6.12 ..J x x x x x x 8.15 8.16 8.17 , and dispersion angle test By ..J 8.7 6.4 6.17 .~ of tesf~amPlelfl~~per Checki ng ~dt~~o~l / design dp ent 5) 6) 7) 8) ~"."~ As per clause no. ..J ..J ..J x Checked By ~ ADE(TL-AC &System Design) DSE(TL-AC & System Design) , ACID 181-20 14 (Rev-"O") RDSOIPE/SPEC/DI 18) 19) 20) 21) PCB Burn in cyclic test Surge and Transient Test EMI test Fire retardant test on soft wool polycarbonate sheet and . "" " x x x x x x x x 8.18 8.19 8.20 7.10 and 7.13 8.6 The acceptance test shall be conducted by inspecting agency as per sampling plan in IS 2500 part-I. The Routine test shall be conducted by firm on each unit during manufacturing. Firm shall keep record for individual unit & a copy shall be endosed in packing of unit. 8.7 Visual test: The unit should be checked visually for dimensions a~ ~~~approved drawing. The general workmanship should be good with all the component properly secured and sharp edges rounded off. Visual check for all possible physica:!!.)(.!?~ificationof compliance of all clause mentioned in this specification shall be done. The dielectric test shall be conducted RMS value of test voltage as 1000 Volts 8.10 The insulation resistance of t~r unit";.~~!Ween ~md all current carrying parts shorted together shall be more than 20 Mega ohms §It a ambient temperature of 55°C measured with 500 V Insulation Tester (megger). Reverse polarity t!?st: The unit shall remain functional after 32 Volts DC 10 Volts dc input termm reverse polarit case the 24 Volts input the unit should tn without any damage. at 110 Volts dc input terminal and one in correct polarity as well as in connected inadvertently to 110 Volts dc supply be for its functioning at upper voltage limit, lower supply system. The unit should work satisfactorily for 12 t room temperature with battery. The illumination level shall also be measured during he performance test and th level shall not be less than 250 Lux at 0.5 meters, 100 Lux at and 30l;ux and 20 Lux at 2.1 meters as stipulated in dause 6.15. The illuminatio sidesi!Qf centre of Emergency Light unit (SLU) at 2.1 m should be uniform or vary within Correct burn - in of embedded (SLU). software version shall be verified for Emergency Light unit Tests to determine the performance and capacity of battery. For proven design of battery, The capacity test on battery shall be conducted during type test of complete unit. For this purpose the battery shall be selected randomly. Capacity/20 or Capacity/10 discharge test as recommended in datasheet of battery with constant discharge current using rheostat shall be done and average room temperature following formula:- shall be noted. Battery capacity shall be calculated by Battery Capacity at 27 0 C = C*T /1 +K (t-27) Ah. C= Current in mA T = Time taken to discharge hrs, K= 0.0043 't = Average temperature in 0 C. The calculated capacity of battery should exceed or match the rated capacity of battery. Mechanical and electrical endurance test: 8.14 The unit will be subjected to 5000 switching operation~ 30 seconds 'ON' period and 30 seconds 'OFF' period in locked chamber with auto recording arrangement. None of the unit component should show sign of damage/deter on. 8.15 Temperature rise tests: (Dry heat run test) The tests shall be carried out as per IEC60571- on the complet~ electronic assembly in closed condition as during normal ope ratiQQ, on full load, placed in test chamber where temperature is progressively raised from ambient from 70·C for 6 hours a~per IEC 60571. At the end of this test the performance test is repeat$g. 8.18 Burn in test On poPulated PCB: It shall b ELRS/SBl;QISII0015 {R.~v:D Oct"2001. Burn in test procedure on Populated PCB to be done at NABL Accredited Lab shall be under: I. Burn-in test shall be undertaken between - 25 0 C to +70 0 C as per temperature in Annexure-1 of ROSO sp3cification No. ELRS/SPEC/SI/0015. cycle given II. Test is to be conducted gOqtinuously for 45 hours i.e. 6 cycles of 7.5 hours on populated PCB of Emergency I"ight unit (SI.;U). III. Test shall be condu & negative temperature Gring energized condition of PCB card in each cycle during positive peak as under. (a) +12V DC is applied on the populated PCB at B+ terminal of PCB (b) The critical most output is of LED cluster drawing power which is measured at LEO+ Terminal PCB ground and the same should be +13.5 V to 16.5 V. IV. This will be measured to ensure the proper functioning of PCB and microprocessor control. V. After completion of burn-in cycles the PCB shall be assembled with emergency light unit. Full performance test as per Para 6.7, 6.12 & Para 8.6.1 shall be conducted after burn-in test of PCB. 8.19 Surge and Transient Tests: The test shall be conducted as per clause 5.4 of IEC - 60571 and Performance to be checked after the test. The Emergency Light unit (SLU) shall be designed such that there will not be any Electromagnetic Interferences and the test shall be conducted for EMI/EMC with relevant clauses of IEC 61000 as under: Pulse re etition rate Volta e eak ii) 2.5 KHz 4KV Surge Test The test shall be carried oulas Test level: 4 KV a) b) iv) er IEC: 6100Q.:4Fq; Ihstallation dass: 4, Enclo.§:tJreconductive part-cont Endosure insulated part- air disch Radiated susceptibility test: As per LEC-6100Q.:4-3 v) Earth Potential test Body without powder coating of the ELU shall be given external voltage of 110V performance of ELU shall not get affected The Emergenoy Ligh following informatiqn printed. i) ii) iii) iv) v) vi) DC II be provided with a name/rating plate on the enclosure. The be available by either etching process or by engraving or screen- Manufacturer's name and address. It will be dearly printed on the enclosure such that it can be seen after fitted SLU in the coach. Type / make, Specification No. Continuous battery rating, short time rating/duration, input voltage range, output voltage range. Connection diagram in an anodized aluminum plate with terminal markings Serial Number of the equipment. Software version loaded. Note: The first two digits shall indicate the year of manufacture. Next two digits month. Next one digit for any type Model, etc. Next three digits manufacturing serial number a) b) c) d) a) b) Component outline in the proximity of the component; ELU manufacturer's name. Sub vendor's name that has assembled SMD components on PCB. Version number of Hardware. The manufacturing serial number. Month and year of manufacture 9.4 Indication plate for meaning of Indication LED red, green and amber shall also be provided below the indication LED as per AnnexureD. 9.5 The equipment and its sub assemblies shall be packed in thermo Cole boxes and the empty spaces shall be filled with suitable filling material. Before keeping in the thermo Cole box, the equipment shall be wrapped with bubble sheet. The equipment shall be finally packed in a wooden case of sufficient strength so that it can withstand bumps and jerks encountered in a road/rail journey. The supplier shall arrange for training to IR personnel as and when required in maintenance and trouble shooting of the system supplied. Firm shall arrange for training of Railway staff in maintenance and troubleshooting of the system .. Indian Railways shall not be responsible for infringement of patent rights arising due to similarity in design, manufacturing process, use of similar components in the design & development of this item and any other factor not mentioned herein which may cause such a dispute. The entire responsibility to settle any such disputes/matters lies with the manufacturer/ supplier. Details / design/documents given by them are not infringing any IPR and they are responsible in absolute and full measure instead of railways for any such violations. Data, specifications and other IP as generated out of interaction with railways shall not be unilaterally used without the consent of ROSa and right of Railways / ROSa on such IP is acceptable to them. The manufacturer shall be required to make available the services of his engineer/engineers free of cost to watch performance of the equipment in service periodically and also carry necessary repairs or replacement under warranty obligations. The necessary spares needed for replacement during service should be available with the service engineer at all possible places where these coaches are maintained. The complete unit except battery shall be guaranteed for satisfactory performance and manufacturing defects for a period of 60 months from the date of commissioning or 72 months from the date of supply whichever is earlier. For the battery guarantee/warranty obligation of the equipment shall be as per IRS condition of contract. ' Firms shall have to comply to ROSa STR no. ROSa/PE/STR/AC/0034-2012 (rev-O) with additional Chromo meter to measure Lux as well as coordinates of LEO to ascertain quality of light. This will be considered for as compulsory requirement at the time of registration /renewal or revalidation of registration as approved vendor of ROSa for this item. The firm shall not engage cartel formation with other firms and shall also submit a declaration in this regard as per annexure attached ofthis specification. The manufacturer shall submit operating & maintenance manual to ROSa and the user Railway containing: a) Bilingual (Hindi and English) instructionsJor operation, maintenance and troubleshooting b) Power & control electrical diagrams showing various connections to Emergency Light unit (SLU). c) Write- up on the working of Emergency Light unit (SLU). I Production units and zonal railway shall provide the arrangement using Push button in the existing wiring circuit of the coach in every trip to check working status of emergency light unit (SLU) as per ROSa Modification sheet no. ROSa/PE/MS//0047-2009(Rev-0) issued by ROSa vide letter no. EL/6.4.6 dated 27.01.2010 18.1 Performa for undertaking against cartel formation to be furnished by the manufacturer We, hereby, give an undertaking that as a Registered Vendor for manufacture and supply of '" will not be a part of a cartel with other vendors and will be quoting competitive rates in the tenders invited by the Indian Railway/PUs. We are aware of the fact that the list the name of our firm from the Master List of Approved cartel formation from any of the Railways/Production Authority i.e. ROSa may deif complaint is received about such Seal and Signature signatory of the firm) Voltage Waveform at DCbus bar at No Load. ERRU off and lnvertars off. Voltage Waveform at DC bus bar • ERRU off andjwth IX bus bar at B2 !.!allO. ERRU ON and single inverter ON. DC bus bar at full RI\lWU load. ERRll ON and single inverter ON. ~ Checked By l1WACfirw waveform at secondary of 415V/UOV transformer of control panel UOVACIlrw waveform at 415V/1l0V transformer <rl control panel (After Filter) Prepared By ~~ BURN-IN TEST emperature in Degrees Blink C Gl'8Bn li$ Red Jf$~ c ....Amber Ii' - It ! ii' ~'-J--.I c:D-Ui 8·bo C c Northern Railway, Baroda House, New Delhi - 110 001. 2 Central Railway, " Floor, Parcel office, CST Mumbai - 400001. 3 Eastern Railway, Fairlie Place, Kolkata - 700 001. 4 South Eastern Railway, Garden Reach, Kolkata - 700 043 5 Southern Railway, Park Town, Chennai - 600 003. 6 Western Railway, Churchgate, Mumbai - 400020. 7 South Central Railway, Rail Nilayam, Secunderabad - 500 371. 8 East Central Railway, Dighi Distt- Vaishali, Hajipur Bihar- 10 South Western Railway, l' Floor, DRM Office, Hubli 11 South East Central Railway, Bilaspur.495004 12 North East Frontier Railway, Maligaon, 13 North Eastern Railway, Gorakhpur- 14 North Western Railway, Jaipur - 302006 15 West Central Railway, Jabalpur-A82001 16 East Coast Railway, BhuvneshW 17 Konkan Railway, Belapur Bhavan 18 19 15 16 17 18 19 20 OTHERS: 1 2 10 HOLES 06 ON BOTH SIDE 150 (j) 0 0 0 0 0 0 0 0 --l (j) 0 0 ~ 01 •• •• •• 1~ 240 150 180 3 -$ ~ 01 0 I I D I -$- I -$ -$- 7 315 375 = RUBBER 2 M.S.ROD 4 CONNECTOR 2 2 COVER (0.8mm Thk.) (261-102) 2 * DT D AK.S C M.M.S. GALVD. M.S.SHEET IS: 1341-Bl MS.SHEET IS: 513-94 (GR-DD) NOTE:- REF NO. PART NO. DESTRIPTION DETAILED DRG NO. 1. ALL DIMENSIONS IN mm. TOLERANCE SHALL BE AS PER IS 2102 2. ffEM 1 &2 SHOULD BE DRAWN AND NOT FABRICATED. 3. VENTILATING HOLES 10 Nos., 06 mm TO BE PROVIDED ON THE SIDE OF THE FITTED. REF : EL/6.4.6/LHB 4. ALL ITEMS SHELL BE GIVEN SURF ACE TREATMENT FOR ANTIRUST & ANTICORROSION BEFORE FINISHING WITH BROKEN WHITE POWDER COATING OF BURGER 302. 5. DOME KEY SHALL BE SUPPLIED 1 No. FOR EACH SET. 6. FOR 110 VfDC W AGO MAKE BLUE CONNECTOR & 24 VfDC PARROT COLOR CONNECTOR. 7. RESISTOR FOR HEAT DISSIPATION UNDER 20% DISCHARGES SHALL BE INSIDE UNIT. IS: 2062-99 WAGOMAKE M.S.SHEET IS: 513-94 (GR-DD) HOUSEING (0.8mm Thk.) TITLE:- IS: 5270-69 2 HINGE (40 mm) 405 IS: 1719-2000 GROMMET = = WOOL CAPTIVE SCREW (M5) 6 = FELT (3mm) NOIEACH PCS. MA TL. SCALE: DRAWING FOR THE EMERGENCY LIGHT UNIT HOUSING FOR LHB TYPE EOG COACHES ** SPEC. REMARKS APPROVED BY : FIRST ISSUED 10.07.2014 SUPERSEDES: NIL l 70 85 150 _II I I t I I 4 U CLAMP BRACKET FOR CONNECTOR 3 MIO M.S. BUSH 2 M.S.SHEET IS 2062-99 M.S. ROD IS 2062-99 U CLAMP BRACKET (1.5 Thk.) M.S.SHEET IS: 1079 U CLAMP BRACKET (1.5 Thk.) M.S.SHEET IS: 1079 4 REF NO. PART NO. DESTRIPTION DETAILEDDRGNO. REF: EL/6.4.6/LHB NOTE:- * I. ALL DIMENSIONS IN nun AND TOLERANCE SHALL BE AS PER IS: 2102. 2. ALL ITEMS SHALL BE GIVEN SURFACE TREATMENT FOR ANTIRUST & ANTICORROSION BEFORE FINISHING WITH BROKEN WHITE POWDER COATING. TlTLE:- NOIEACHPCS. MATL. SCALE: DRAWING FOR THE ANTI-THEFT HOLDING CLAMP FOR BATTERY OF EMERGENCY LIGHT HOUSING OT. o A.K.S. C M.M.S. SPEC. * * * * REMARKS APPROVED BY : FIRST ISSUED 10.07.2014 SUPERSEDES : NIL
© Copyright 2024 ExpyDoc