INEX PARTYWALL NLB-190PB ™ ANY BUILDING • ANY SURFACE • ANYWHERE STEEL FRAME: INEX>RENDERBOARD16 FRL MIN –/90/90 & Rw+Ctr 57 NOV 2014 Page 1 INEX>RENDERBOARD16 SYSTEM NLB-190PB A SUPER HIGH PERFORMING PARTY WALL SYSTEM FOR STEEL FRAME LIGHTWEIGHT CONSTRUCTION INTERTENANCY & COMMON WALLS FRL –/120/120 Rw+Ctr = 57 2 x 64x50 0.75 BMT STEEL STUD FRAMES WITH 10mm GAP 8 GAUGE WING TEK SCREWS AT 200mm c/c; MIN CLASS 3 BACKING BOARD, IF JOINT REQUIRED (NO FIRE SEALANT REQUIRED) 16mm THICK 2700x600 INEX>RENDERBOARD16 OPTIONS FOR INSULATION (SEE TABLE PAGE 3) 10mm STANDARD GRADE PLASTERBOARD RECESSED EDGE: TAPED/SET JOINT (NO FIRE SEALANT REQUIRED) 190mm O/A WALL THICKNESS CAVITY SERVICES BOTH SIDES APPROVED (ELECTRICAL OR WATER SERVICES) TONGUE & GROOVE JOINT TO INEX>RENDERBOARD16 NON-LOAD BEARING / DISCONTINUOUS CONSTRUCTION CLASS 2, 3 OR 4 PART BUILDING, TYPE A CONSTRUCTION INTERTENANCY WALLS AND COMMON WALLS – CAVITY SERVICES BOTH SIDES UBIQ Pty Ltd, 1/17 Chester St, Annandale NSW 2038 Australia • ABN 14 146 086 142 • (02) 9519 4460 • [email protected] • www.ubiq.com.au INEX>PARTYWALL TYPE NLB-190PB INEX PARTYWALL NLB- 190PB ™ ANY STEEL FRAME: INEX>RENDERBOARD16 FRL MIN -/90/90 & Rw+Ctr 57 BUILDING • ANY SURFACE • ANYWHERE 5 4 x SCREWS AT EACH NOGGIN 150 VERTICAL JOINT (TYPICAL) NOGGIN EQEQ NOGGIN 100 FIT SHEETS VERTICAL FLOOR TO SOFFIT 15 NOV 2014 Page 2 1 SCREWS AT 200mm c/c AND OFFEST AT JOINTS 200 100 STEEL FRAME: INEX>RENDERBOARD16 FRL MIN –/90/90 & Rw+Ctr 57 IF JOINT REQUIRED BACKING BOARD CUT FROM INEX>RENDERBOARD16 AND EXTEND AS FAR AS STUD FACES (NO FIRE MASTIC REQUIRED) NOTE: PLASTERBOARD FACING OMITTED FOR CLARITY MAX 600 MAX 600 2 3 3 4 1 6 1 2700x600 >RENDERBOARD16 2700x600 INEX INEX>RENDERBOARD16 4 64x50 64x500.75 0.75BMT BMTSTEEL STEELSTUD STUDFRAME FRAME 2 STANDARDGRADE GRADEPLASTERBOARD PLASTERBOARD STANDARD 5 GUAGEWING WINGTEK TEKSCREWS, SCREWS,MIN MINCLASS CLASS33 88GAUGE 3 OPTIONS OPTIONS FOR FOR INSULATION INSULATION 6 MIN 10mm 10mm GAP GAP MIN 190 170 1 (FIXED (FIXEDVERTICALLY) VERTICALY) (TAPED/SETJOINT JOINT– -NO NOFIRE FIREMASTIC MASTICREQUIRED) REQUIRED) (TAPED/SET (SEE 3) 3) (SEETABLE TABLEPAGE PAGE 190mm O/A THICKNESS (BY (BYSTUDCO STUDCOBUILDING BUILDINGSYSTEMS) SYSTEMS) NON-LOAD BEARING / DISCONTINUOUS CONSTRUCTION CLASS 2, 3BEARING or PART 4/BUILDING, TYPE A CONSTRUCTION NON-LOAD DISCONTINUOUS CONSTRUCTION INTERTENANCY WALLS AND COMMON WALLS CAVITY SERVICES BOTH SIDES CLASS 2, 3 OR 4 PART BUILDING, TYPE A CONSTRUCTION INTERTENANCY WALLS AND COMMON WALLS – CAVITY SERVICES BOTH SIDES UBIQ Pty Ltd, 1/17 Chester St, Annandale NSW 2038 Australia • ABN 14 146 086 142 • (02) 9519 4460 • [email protected] • www.ubiq.com.au INEX PARTYWALL NLB-190PB ™ ANY BUILDING ANY SURFACE • • ANYWHERE STEEL FRAME: INEX>RENDERBOARD16 FRL MIN –/90/90 & Rw+Ctr 57 10 16 64 10 64 NOV 2014 Page 3 16 10 SOFFIT 20 64 x 50 TOP TRACK DEFELECTION HEAD FIXED AT Max. 600mm CENTRES 70 75 TOP OF SHEETS 20mm CLEAR OF SOFFIT TROWELED ON BOSTIK 'FIREBAN ONE' POLYURETHANE SEALANT TOP FIXING TO STUD (DO NOT FIX THROUGH TRACK HEAD) TOP OF STUD 15mm CLEAR OF SOFFIT TOP NOGGIN TOP NOGGIN STANDARD GRADE PLASTERBOARD GLUED TO RENDERBOARD FIXING TO TOP NOGGIN AT CENTRE OF NOGGIN INEX>RENDERBOARD16 ALL STEEL COMPONENTS MIN 0.75 BMT INEX>RENDERBOARD16 64 x 32 BOTTOM TRACK FIXED AT Max. 600mm CENTRES 15 10 FIXING TO BOTTOM TRACK TROWELED ON BOSTIK 'FIREBAN ONE' POLYURETHANE SEALANT BASE INSULATION OPTIONS TYPE OF INSULATION 2 x 70mm R2.2 24kg/m3 GLASS WOOL 2 x 70mm R1.5 14kg/m3 GLASS WOOL 1 x 145mm R3.0 7kg/m GLASS WOOL 3 Fire Resistance Level F/R/L Acoustic Airborne Rw / Rw + Ctr –/120/12064/57 Exova-31525900 Kilargo-629WA Test –/120/12064/57 Exova-31525900 PKA-142 Opinion –/90/9064/57 Exova-31525900 Acoustic Services Measured SPL AAAC 5 Star Rating of < 30dBA Kilargo-004 Test Kilargo-005 Test PKA-142 Opinion UBIQ Pty Ltd, 1/17 Chester St, Annandale NSW 2038 Australia • ABN 14 146 086 142 • (02) 9519 4460 • [email protected] • www.ubiq.com.au INEX PARTYWALL NLB-190PB ™ ANY BUILDING • ANY SURFACE • ANYWHERE STEEL FRAME: INEX>RENDERBOARD16 FRL MIN –/90/90 & Rw+Ctr 57 WALL SYSTEM APARTMENT SIZE 82m2 SPACE GAIN 2.75m2 INTERTENANCY WALL MIN FRL –/90/90 MIN Rw+Ctr 50 NOV 2014 Page 4 EXTERNAL WALL MIN FRL –/60/60 TYPICAL AAC WALL SYSTEM THICKNESS (mm) 228230 INEX>RENDERBOARD SYSTEM THICKNESS (mm) 190135 GAIN THE SPACE – SELL/RENT THE SPACE FOR A TYPICAL 80m2 TWO BEDROOM APARTMENT INEX>PARTY & INEX>EXTERNAL WALLS DELIVER AN ADDITIONAL 2.75m2 INTERNAL STRATA AREA (WHEN REPLACING TYPICAL INTERTENANCY AND COMMON WALLS AT 228mm THICK & TYPICAL EXTERNAL WALL AT 230mm THICK) UBIQ Pty Ltd, 1/17 Chester St, Annandale NSW 2038 Australia • ABN 14 146 086 142 • (02) 9519 4460 • [email protected] • www.ubiq.com.au
© Copyright 2024 ExpyDoc