ilis Partnerfolder PerkinElmer English

Chroma
™
Optical Spectral Analysis
and Color Measurement
Chroma™
Powerful software package for optical spectral
analysis and color measurement
Color is an important design and product recognition feature, one that can mean the
difference between market success and failure. Particularly when using natural or
recycled raw materials with varying compositions, continuous, objective monitoring
of the effect of color is a key prerequisite for uniform quality.
With the Chroma software package and a PC-controlled spectrophotometer, you can
now determine the transmission and reflection properties of solids and liquids precisely, and on the basis of these calculate and graphically display color values according
to both the Helmholtz and the CIELAB method.
Chroma links measurement and evaluation with a powerful database in which all
results are stored in an optimized structure. The Chroma software ensures the traceability and complete documentation of all measurements to actively support you in
implementing your quality standards.
Features
> Directly controls spectrophotometers from a variety of manufacturers
> Integrated color determination according to ISO 11664/CIE 15
> Graphic, interactive display of measurement results
> Wide range of evaluation options
> Integrated database with trend analysis
> Special functions for measuring glass and plastic
> Clear, intuitive user interface structured according to work processes
Chroma -compatible spectrophotometers
from PerkinElmer
™
Chroma™
®
PerkinElmer Lambda™ 25/35/45
PerkinElmer Lambda™ 650/750/850/950/1050
The PerkinElmer LAMBDA 25, 35 and 45 photometers are
equipped with double-beam optics and are designed for
extremely low-noise transmission measurements in the
UV/VIS range (190 to 1100 nm) to approx. 3.5 absorption
units.
With the models LAMBDA 650, 750, 850, 950 and 1050,
PerkinElmer offers a wide range of double-beam UV/VIS/NIR
spectrophotometers with double monochromators for applications demanding maximum precision. All models have
the same basic set-up with a large, flexible sample compartment and a variety of possible expansion capabilities.
The LAMBDA 650 with its sensitive photomultiplier detector
permits measurements to 6 absorption units in the UV/VIS
range (190 to 900 nm).
The LAMBDA 25 is equipped with a 1 nm fixed slit, while
on the LAMBDA 35 and 45 the slit width is adjustable in
the range of 0.5 to 4 nm.
The pre-monochromator of the LAMBDA 45 halves the
scattered light from 0.01 %T to 0.005%T.
The LAMBDA 850 expands the photometric range to 8 absorption units. The LAMBDA 750, 950 and 1050 models
open up the NIR range out to 3300 nm. The LAMBDA 750
and 950 are equipped with PMT/PbS detectors, and the
Lambda 1050 is additionally fitted with a highly sensitive
InGaAs detector for extremely precise measurements in
the lower NIR range of approx. 800 to 2500 nm.
PerkinElmer and the PerkinElmer logo are registered trademarks of PerkinElmer, Inc.
Chroma™
Features and Modules
Basic functions
>Transmission measurement in air with correction of the surface reflectance
>Transmission measurement in immersion with correction of the absorbance
>Reflection measurement with correction of the white standard
>Normalization of transmittance spectra for any layer thickness
>Graphical presentation of transmittance, absorbance and reflectance spectra with
direct comparison of multiple measurements
>Data export to CSV files for further processing in other programs
>Convenient management of all measuring parameters in methods
>User-defined attributes for organizing measurements
>Extendable by customer-specific calculations
>User acces control with convenient rights management
Database module
>Automatic storage of all measurements into the integrated database
>Comprehensive list view of all measuring results
>Filtering by multiple criteria (date, name, attributes, etc.)
>Management of favorites for fast access to reference measurements
>Statistical analysis using trend charts
Serial measurement module
>Measurement and simultaneous display of up to ten spectra
>Archiving as individual measurements or as an averaged measurement
>Direct control of automatic sample changers
Color analysis module
>Determination of the tristimulus values (X, Y, Z) and the chromaticity coordinates (x, y, z)
acc. to ISO 11664-3:2012
>Color determination according to Helmholtz (DWL, S, A) and presentation in the CIE
chromaticity diagram
>Color determination according to CIELAB (L*, a*, b*, E*ab, C*ab, hab) acc. to ISO 11664-4:2008
and presentation in the L*a* b* color space (CIE 1976)
>Reference to 2° or 10° standard colorimetric observer (ISO 11664-1:2007) and standard
illuminants A or D65 (ISO 11664-2:2007) or illuminant C (CIE 15:2004)
Glass analysis module
>Calculation of the parameters Te, TV, TUV, Re, RV, Ra of glazings acc. to ISO 9050:2003 and
EN 410:2011
>Calculation of the light transmittance TL of greenhouse glass acc. to NEN 2675:1990
>Determination of the redox state of flint glass (Fe2+/Fe3+ ratio) acc. to Bamford/Hudson
>Determination of the Fe2+ and Fe3+ concentrations acc. to Lambert-Beer law
>Determination of the inspectability of amber glass (Amin, I) acc. to VLB Berlin
Custom adaptations and special versions are possible on request. No responsibility is taken for the correctness of the
information. All information is subject to change without prior notice. Product website: www.ilis.de/en/chroma.html
copyright © ilis gmbh, all rights reserved. Version 9/2014. Photos: bottles, broken glass: © Uwe Mühlhäuser; laboratory
glassware: © Karramba Production - Fotolia; powder: © Sylwia Kachel - Fotolia; crayon: © Africa Studio - Fotolia; color bucket:
© ristaumedia.de - Fotolia; Concept and realization: gräßel kommunikation
ilis gmbh Konrad-Zuse-Straße 22 D-91052 Erlangen
Fon +49 (9131) 9 74 77 90 Fax +49 (9131) 9 74 77 99
[email protected] www.ilis.de