Chroma ™ Optical Spectral Analysis and Color Measurement Chroma™ Powerful software package for optical spectral analysis and color measurement Color is an important design and product recognition feature, one that can mean the difference between market success and failure. Particularly when using natural or recycled raw materials with varying compositions, continuous, objective monitoring of the effect of color is a key prerequisite for uniform quality. With the Chroma software package and a PC-controlled spectrophotometer, you can now determine the transmission and reflection properties of solids and liquids precisely, and on the basis of these calculate and graphically display color values according to both the Helmholtz and the CIELAB method. Chroma links measurement and evaluation with a powerful database in which all results are stored in an optimized structure. The Chroma software ensures the traceability and complete documentation of all measurements to actively support you in implementing your quality standards. Features > Directly controls spectrophotometers from a variety of manufacturers > Integrated color determination according to ISO 11664/CIE 15 > Graphic, interactive display of measurement results > Wide range of evaluation options > Integrated database with trend analysis > Special functions for measuring glass and plastic > Clear, intuitive user interface structured according to work processes Chroma -compatible spectrophotometers from PerkinElmer ™ Chroma™ ® PerkinElmer Lambda™ 25/35/45 PerkinElmer Lambda™ 650/750/850/950/1050 The PerkinElmer LAMBDA 25, 35 and 45 photometers are equipped with double-beam optics and are designed for extremely low-noise transmission measurements in the UV/VIS range (190 to 1100 nm) to approx. 3.5 absorption units. With the models LAMBDA 650, 750, 850, 950 and 1050, PerkinElmer offers a wide range of double-beam UV/VIS/NIR spectrophotometers with double monochromators for applications demanding maximum precision. All models have the same basic set-up with a large, flexible sample compartment and a variety of possible expansion capabilities. The LAMBDA 650 with its sensitive photomultiplier detector permits measurements to 6 absorption units in the UV/VIS range (190 to 900 nm). The LAMBDA 25 is equipped with a 1 nm fixed slit, while on the LAMBDA 35 and 45 the slit width is adjustable in the range of 0.5 to 4 nm. The pre-monochromator of the LAMBDA 45 halves the scattered light from 0.01 %T to 0.005%T. The LAMBDA 850 expands the photometric range to 8 absorption units. The LAMBDA 750, 950 and 1050 models open up the NIR range out to 3300 nm. The LAMBDA 750 and 950 are equipped with PMT/PbS detectors, and the Lambda 1050 is additionally fitted with a highly sensitive InGaAs detector for extremely precise measurements in the lower NIR range of approx. 800 to 2500 nm. PerkinElmer and the PerkinElmer logo are registered trademarks of PerkinElmer, Inc. Chroma™ Features and Modules Basic functions >Transmission measurement in air with correction of the surface reflectance >Transmission measurement in immersion with correction of the absorbance >Reflection measurement with correction of the white standard >Normalization of transmittance spectra for any layer thickness >Graphical presentation of transmittance, absorbance and reflectance spectra with direct comparison of multiple measurements >Data export to CSV files for further processing in other programs >Convenient management of all measuring parameters in methods >User-defined attributes for organizing measurements >Extendable by customer-specific calculations >User acces control with convenient rights management Database module >Automatic storage of all measurements into the integrated database >Comprehensive list view of all measuring results >Filtering by multiple criteria (date, name, attributes, etc.) >Management of favorites for fast access to reference measurements >Statistical analysis using trend charts Serial measurement module >Measurement and simultaneous display of up to ten spectra >Archiving as individual measurements or as an averaged measurement >Direct control of automatic sample changers Color analysis module >Determination of the tristimulus values (X, Y, Z) and the chromaticity coordinates (x, y, z) acc. to ISO 11664-3:2012 >Color determination according to Helmholtz (DWL, S, A) and presentation in the CIE chromaticity diagram >Color determination according to CIELAB (L*, a*, b*, E*ab, C*ab, hab) acc. to ISO 11664-4:2008 and presentation in the L*a* b* color space (CIE 1976) >Reference to 2° or 10° standard colorimetric observer (ISO 11664-1:2007) and standard illuminants A or D65 (ISO 11664-2:2007) or illuminant C (CIE 15:2004) Glass analysis module >Calculation of the parameters Te, TV, TUV, Re, RV, Ra of glazings acc. to ISO 9050:2003 and EN 410:2011 >Calculation of the light transmittance TL of greenhouse glass acc. to NEN 2675:1990 >Determination of the redox state of flint glass (Fe2+/Fe3+ ratio) acc. to Bamford/Hudson >Determination of the Fe2+ and Fe3+ concentrations acc. to Lambert-Beer law >Determination of the inspectability of amber glass (Amin, I) acc. to VLB Berlin Custom adaptations and special versions are possible on request. No responsibility is taken for the correctness of the information. All information is subject to change without prior notice. Product website: www.ilis.de/en/chroma.html copyright © ilis gmbh, all rights reserved. Version 9/2014. Photos: bottles, broken glass: © Uwe Mühlhäuser; laboratory glassware: © Karramba Production - Fotolia; powder: © Sylwia Kachel - Fotolia; crayon: © Africa Studio - Fotolia; color bucket: © ristaumedia.de - Fotolia; Concept and realization: gräßel kommunikation ilis gmbh Konrad-Zuse-Straße 22 D-91052 Erlangen Fon +49 (9131) 9 74 77 90 Fax +49 (9131) 9 74 77 99 [email protected] www.ilis.de
© Copyright 2024 ExpyDoc