Parts Introduction

Parts Introduction
Three Color LED
Red -Stand by.
Weak Red -Buttons have been locked, press any button or
shift any switch to unlock at Single mode or Seq. mode, press
button LOCK/UNLO to unlock at Program mode.
Blinking Red -Low power indication, Li-ion battery needs to
be recharged. You can use a PC’s USB port to charge.
Green -Transmitter is in the status START or STEPER at
Program mode, or transmitter is charged full when charging.
Blinking Green -Transmitter is transmitting RF signal.
Yellow -Pausing running firing program at Program mode.
Blinking Yellow -Charging.
3-Position Switch
Transmitter Mode Selection Switch:
Single -Dividual Firing mode
Seq. -Interval Firing m ode
Program -Program / Stepper Firing mode
Digital Readout 1
Transmitter Address, total 10 addresses from 0 to 9.
Address Button
Twice Quick Press actives Digital Readout 1,
number color turns from dark red to bright red . Then
press again to change address .
Label
Antenna
Main Switch
Letter Buttons ABCD
Only when one of the buttons is pressed,
the corresponding button light is on, the
other press of other button is available.
1.When 3-Position Switch is at Single,
Digital Readout 2 reads 01, 12 or Fc., Letter
Buttons ABCD are Address 2. When
Address 1 and Address 2 are used together,
the press of Numberical Buttons is available.
2.When 3-Position Switch is at Single,
Digital Readout 2 reads 32, Letter Buttons
ABCD represent corresponding banks of
the module RF32D or PC32Q etc..
There are 4 banks ABCD in the modules.
3.When 3-Position Switch is at Seq. or
Program, Letter Buttons ABCD are
Address 2. When Address 1 and
Address 2 are used together, pressing
Interval Firing Buttons or Program
Firing Buttons is available.
Interval Firing Buttons
When 3 - Position Switch is at Seq . , and
Letter Button A,B,C or D is selected ,
pressing one of the buttons is available .
Seq . - Fire cues / module ( s ) according
to the interval of Digital Readout 2 .
All - Fire all cues / modules in the same
time without any delay.
Rubber Supports
Remove Rubber Supports to
unscrew the transmitter .
Numberical Buttons
Only when 3 - Position Switch is at Single
pressing one of the buttons is available.
Among when Digital Readout 2 reads 32,
buttons 9,10,11&12 are disable, for there is
not Cue 9,10,11 or 12 in a 32 Cue module.
In other status the 12 buttons are available.
Digital Readout 2
When 3-Position Switch is at Single,
TCF200-U works in Dividual Firing mode,
Digital Readout 2 indicates the type of
module which the transmitter will
work with. There are 4 types selectable
following:
01 - 1 Cue Module RF1A or RF1K etc.,
12 - 12 Cue Module RF12 etc.,
32 - 32 Cue Module RF32D or PC32Q
etc.,
Fc. - Master Unit
When 3-Position Switch is at Seq.,
TCF200-U works in Interval Firing
mode, Digital Readout 2 indicates
interval , there is 11 options following:
0.1 - Interval 0.1s,
0.2 - Interval 0.2s,
......etc..
Type / Interval Button
Twice Quick Press of the right button
actives Digital Readout 2, then press to
change reading.
Program Firing Buttons
Only when 3-Position Switch is at Program,
Program Firing Buttons are available. Buttons can
work with PC32Q / Master unit and RF1K /
RF12 /RF32D etc..
1.Works with PC32Q / Master unit:
START- Start running program
PAUSE/CONT- Pause or continue running
program
STEPER - Stepper Firing .
STOP -Stop running program
LOCK/UNLO - Lock or unlock Program Firing
Buttons. Only when unlocked, pressing Program
Firing Buttons is available.
2.Works with RF1K / RF12 / RF32D:
Only buttons STEPER, STOP and LOCK/UNLO
are available. Users need to press STOP before
use STEPER.
3.When START is pressed, STEPER is disable.
Press STOP to reset.
When STEPER is pressed, START, PAUSE/CONT
are disable. Press STOP to reset. The responding
Button Light will be on when button is working.
Camera Stand Nut
Battery Case
Rechargable Li-ion Battery,
specifications:
Sizes:52mm (L)x37mm (W)x6mm(H)
Voltage: 3.7V DC
Capacity: 1100mAh
Mini USB Port
Connect Special USB Wire to charge
or have MUSIC CONTROL.
Special USB Wire
1 . Used to connect
TCF200 - U and computer
to charge;
2. Connected with
Audio-USB Wire together
to connect TCF200-U and
audio player to
have MUSIC CONTROL.
OOK / FSK Changer
Transmitter should have the same
modulation type as the matched
modules before use. For example,
OOK type -RF1A, RF1M, RF12, RF32C
FSK type -PC32Q, RF1K, RF32D &
MASTER unit
Audio - USB Wire
Connected with Special USB
Wire to connect TCF200-U and
audio player to have MUSIC
CONTROL.
Notes:
1 . User can use replacement of rechargable Li - ion battery , the
voltage must be the same 3.7V and the sizes cann’t be more than the
the above values (see Battery Case) .
2. If a audio analyzer is used, earphone cann’t be connected to the
analyzer withTCF200-U, otherwise MUSIC CONTROL may fail.
3. Only the MP3 music file combined by
RFRemotech Melody Combining Software
can control TCF200-U.
Application Sample 1
Sample 1-Works with 12 pcs of AlphaFire module RF1A
Dividual Firing Mode
Interval Firing Mode
Stepper Firing Mode
Steps of Learning:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6 - Step7A-Step8
Steps of Learning:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6A - Step8
Steps of Learning:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6A - Step7
Steps of Firing:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6 - Step7 B - Step8
Steps of Firing:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6 B - Step7 - Step8
Steps of Firing:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6 B - Step7
Step1 - Select OOK
Step1 - Select OOK
Step1 - Select OOK
Step2 - Turn on power
Step2 - Turn on power
Step2 - Turn on power
Step3 - Select Single
Step3 - Select Seq.
Step3 - Select Program
Step4 - Select Address No.6
Step4 - Select Address No.5
Step4 - Select Address No.2
Step5 - Press B
Step5 - Press B
Step5 - Select 01
Step6 - Press A
FIRE
FIRE
FIRE
OFF
OFF
OFF
LEARN
LEARN
TEST
LEARN
TEST
TEST
Step6A - Have module ready
to learn transmitter.
Step6B - Have module armed
to fire .
Step7 - Select 0.8.
Step8-Press Seq..
ARM
Step8 - Press 9
ARM
ARM
Step7A - Have module ready
to learn transmitter
Step7B - Have module armed
to fire .
Step6A - Have module ready
to learn transmitter.
Step6B - Have module armed
to fire .
Step7 - Press STEPER.
The Button 9 and Address No . 6 of the TCF200 - U works with
the AlphaFire module RF1A in Dividual Firing Mode .
The Address No . 5 - B of the TCF200 - U works with the
AlphaFire module RF1A in Interval Firing Mode .
The Address No . 2 - B of the TCF200 - U works with the
12 pcs of AlphaFire module RF1A in Stepper Firing Mode .
Notes:
Only have " Steps of Learning " , then " Steps of Firing " is available .
Notes:
Only have “Steps of Learning” of Dividual Firing Mode and " Steps of
Learning " of Interval Firing Mode, then this " Steps of Firing "
is available .
Notes:
Only have “Steps of Learning” of Dividual Firing Mode and " Steps of
Learning " of Program Firing Mode, this " Steps of Firing " is
available .
Only Buttons STEPER and LOCK/UNLO is available in the situation,
Buttons START, PAUSE/CONT & STOP are disable.
Application Sample 2
Works with MS12Q module RF12
Dividual Firing Mode
Steps of Learning:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6 - Step7A-Step8
Steps of Firing:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6 - Step7 B - Step8
Interval Firing Mode
Stepper Firing Mode
Steps of Learning:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6A - Step8
Steps of Learning:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6A - Step7
Steps of Firing:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6 B - Step7 - Step8
Steps of Firing:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6 B - Step7
Step1 - Select OOK
Step1 - Select OOK
Step1 - Select OOK
Step2 - Turn on power
Step2 - Turn on power
Step2 - Turn on power
Step3 - Select Single
Step3 - Select Seq.
Step3 - Select Program
Step4 - Select Address No.6
Step4 - Select Address No.5
Step4 - Select Address No.2
Step5 - Press B
Step5 - Press B
Step6A - Have module ready
to learn transmitter.
Step6B - Have module armed
to fire .
Step7 - Select 0.8
Step8-Press Seq..
Step6A - Have module ready
to learn transmitter.
Step6B - Have module armed
to fire .
Step7 - Press STEPER.
Step5 - Select 12
Step6 - Press A
Step7A - Have module ready
to learn transmitter
Step7B - Have module armed
to fire .
Step8 - Press 9
Address No . 6 of the TCF200 - U works with the MS12Q module
RF12 in Dividual Firing Mode .
The Address No . 5 - B of the TCF200 - U works with the
MS12Q module RF12 in Interval Firing Mode .
The Address No . 2 - B of the TCF200 - U works with the
MS12Q module RF12 in Stepper Firing Mode .
Notes:
Only have " Steps of Learning " , then " Steps of Firing " is available .
Notes:
Only have " Steps of Learning " , then " Steps of Firing " is available .
Notes:
Only have " Steps of Learning " , then " Steps of Firing " is available .
Only Buttons STEPER and LOCK/UNLO is available in the situation,
Buttons START, PAUSE/CONT & STOP are disable.
Application Sample 3
Works with MS32Q module RF32D.
Dividual Firing Mode
Interval Firing Mode
Stepper Firing Mode
Steps of Learning:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6A - Step7
Steps of Learning:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6A - Step8
Steps of Learning:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6A - Step7
Steps of Firing:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6 B - Step7 - Step8
Steps of Firing:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6 B - Step7 - Step8
Steps of Firing:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6 B - Step7
Step1 - Select FSK
Step1 - Select FSK
Step1 - Select FSK
Step2 - Turn on power
Step2 - Turn on power
Step2 - Turn on power
Step3 - Select Single
Step3 - Select Seq.
Step3 - Select Program
Step4 - Select Address No.6
Step4 - Select Address No.5
Step4 - Select Address No.2
Step5 - Press B
Step5 - Press B
Step5 - Select 32
MS32Q
Wired
Power
Step7 - Press A.
Step8 - Press 7 to fire Cue 7 of
Bank A of the module RF32D .
The Address No . 6 of the TCF200 - U works with the
MS32Q module RF32D in Dividual Firing Mode .
Notes:
Only have " Steps of Learning " , then " Steps of Firing " is available .
Numberical Buttons 9, 10, 11 & 12 are disable in this situation.
When firing, Letter Button A,B,C or D should be pressed to select
bank before pressing Numberical Button to fire the correlative
cue.
Power
MS32Q
MS32Q
Step6A - Have module ready
to learn transmitter
Step6B - Have module armed
to fire .
Wired
Wired
Power
Step6A - Have module ready
to learn transmitter.
Step6B - Have module armed
to fire .
Step6A - Have module ready
to learn transmitter.
Step6B - Have module armed
to fire .
Step7 - Select 0.8
Step8-Press Seq..
Step7 - Press STEPER.
The Address No . 5 - B of the TCF200 - U works with the
MS32Q module RF32D in Interval Firing Mode .
The Address No . 2 - B of the TCF200 - U works with the
MS32Q module RF32D in Stepper Firing Mode .
Notes:
Only have " Steps of Learning " , then " Steps of Firing " is available .
Notes:
Only have " Steps of Learning " , then " Steps of Firing " is available .
Only Buttons STEPER and LOCK/UNLO is available in the situation,
Buttons START, PAUSE/CONT & STOP are disable.
Application Sample 4
RFRemotech
RFRemotech Melody Combining Software
Melody
Timeline
2H30M00S000MS
Location : 1H32M56S200MS
4
Last Point
2H32M56S200MS
2H44M50S150MS
List
Input Melody
First Point
Locate
First Point
0 : 00 : 00 . 000
0 : 30 : 00 . 000
2 : 25 : 00 . 500
A Cute Boy
Smile Song
Spring Arrival
L ast Point
Delete
Time
0 : 03 : 20 . 120 0 : 03 : 20 . 120
0 : 35 : 50 . 100 0 : 05 : 50 . 100
2 : 30 : 00 . 000 0 : 04 : 59 . 500
Cut
RFRemotech
Step1-Generate combined music ABC
Import
Export
Help
Step8 - Turn on power
Generate Firing Point
Input Melody
Program
Timeline Length
Step1 - Select FSK
Amplify
0
2 : 37 : 42 : 525
5 : 15 : 25 : 050
7 : 54 : 07 : 575
10 : 30 : 50 : 100
0
2 : 37 : 42 : 525
5 : 15 : 25 : 050
7 : 54 : 07 : 575
10 : 30 : 50 : 100
First Point
2H44M50S150MS
Generate Individual Firing Point
Generate Firing Point
according to Melody
Firing sequence: No . 1
Multiple Firing Point Setting According Sequence and Interval
Firing Interval
Mark Firing Point
Select receiver & Cue
Receiver
OPQ
XYZ
A
+ Creat Receiver
Firing sequence: No . 1
Available Receivers & Cues
Receiver
Cue
A5
OPQ
A6
XYZ
A7
A
A8
+ Creat Receiver
B1
B2
B3
B4
B5
B6
Cue
A5
A6
A7
A8
B1
B2
B3
B4
B5
B6
H
M
S
MS
You can click your mouse on time anxis to locate
Step2 - Turn on power
Generate
Generate
Step3 - Select Program
Step4 - Select Address No.2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Firing Point Marking
Beginning
Beginning
Beginning
Beginning
Beginning
Beginning
Beginning
Beginning
Beginning
Beginning
Beginning
Beginning
Beginning
Beginning
Beginning
Beginning
Step6A - Have module ready
to learn transmitter.
Step6B - Have module armed
to fire .
Step7 - Press START to send
command to module.
The Address No . 2 - A of the TCF200 - U works with the
MB32Q module PC32Q in Program Firing Mode .
Notes:
Only have " Steps of Learning " , then " Steps of Firing " is available .
S
M
MS
First Firing Point Locating
+ Creat Receiver
Sequence Firing Point
Receiver
Add
Beginning
ABC
1
Beginning
ABCDSF
3
Beginning
ABEF
4
Beginning
AER5678
6
Beginning
ABC
7
Delete
Beginning
ABC
8
Beginning
ABC
9
ABFH
10
Beginning
ABFH
11
Beginning
ABFH
12
Change
Beginning
ABGHI
13
Sequence
ABRE
14
ABD
15
Beginning
ABE
16
Beginning
ABE
17
Generate
Beginning
ABE
18
ABE
19
H
S
M
MS
A is the default button.
XYZ
215 Firing Points
Cue Firing Point Locating Select
A2 00H32M56S320MS
A2 00H32M56S320MS
00H32M56S320MS
B1
A8 00H32M56S320MS
00H32M56S320MS
C1
00H32M56S320MS
C5
00H32M56S320MS
C6
D1 00H32M56S320MS
D2 00H32M56S320MS
D5 00H32M56S320MS
D9 00H32M56S320MS
00H32M56S320MS
B1
00H32M56S320MS
B2
A5 00H32M56S320MS
A6 00H32M56S320MS
00H32M56S320MS
B1
00H32M56S320MS
C1
Firing Receiver 51units Total Time 2H30M50S300MS
Receiver List
Cue Firing Point Locating Modify / Delete
A2 00H32M56S320MS Modify / Delete
A2 00H32M56S320MS Modify / Delete
B1 00H32M56S320MS Modify / Delete
A8 00H32M56S320MS Modify / Delete
C1 00H32M56S320MS Modify / Delete
C5 00H32M56S320MS Modify / Delete
C6 00H32M56S320MS Modify / Delete
D1 00H32M56S320MS Modify / Delete
D2 00H32M56S320MS Modify / Delete
D5 00H32M56S320MS Modify / Delete
D9 00H32M56S320MS Modify / Delete
B1 00H32M56S320MS Modify / Delete
B2 00H32M56S320MS Modify / Delete
A5 00H32M56S320MS Modify / Delete
A6 00H32M56S320MS Modify / Delete
B1 00H32M56S320MS Modify / Delete
B2 00H32M56S320MS Modify / Delete
A5 00H32M56S320MS Modify / Delete
A6 00H32M56S320MS Modify / Delete
B1 00H32M56S320MS Modify / Delete
Receiver
ABC
ABCDSF
ABEF
AER5678
ABC
ABC
ABC
ABFH
ABFH
ABFH
ABGHI
ABRE
ABD
ABE
ABE
ABE
ABD
ABE
ABE
ABE
Total 215 Firing Points
Step5 - Press A
H
You can click your mouse on time anxis to locate the point
OPQ
Cue Select
A4
A5
A6
A7
A8
B1
B2
B4
B5
B6
B7
B8
C1
C2
C3
C4
C5
Firing Points List
Firing Sequence
Step10 - Select No.2
Last Point
2H32M56S200MS
Firing Point Locating
Step9 - Select Program
10H30M50S100MS
Location : 1H32M56S200MS
Steps of Firing:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6 B - Step7
RFRemotech Wireless Firing Software
RFRemotech Wireless Firing System - [ E : \ WirelessRadio \ 123 . fir ]
New Open Save Save As
Steps of Learning:
Step1 - Step2 - Step3 - Step4 - Step5 - Step6A - Step7
Music Control
Program Firing Mode
RFRemotech Melody Combining Software
Step2 - Input ABC
Manual Program Firing Mode
1
2
3
Name
Combine
Works with MB32Q receiver PC32Q.
The Dividual Firing Mode and Interval Firing
Mode are the same as in Application Sample 3 .
No .
Firing Receiver 51 unit
Download Program to Receiver
OPQ
XYZ
A
Step3 - Generate receiver
programs OPQ, XYZ & A.
Upload Program from Receiver
Program List
DEMO according to
All factors
Selected receivers
Time from
H
to
H
Select All
Delete
Total Time 3H45M56S300MS
Step4 - Download firing programs OPQ,
XYX and A to
the 3 receivers
respectively.
Step5 - Make the 3 receivers OPQ, XYZ and A work with
transmitter according to the “Steps of Learning” of Manual
Program Firing Mode, the 3 receivers learn the same Address
No. 2-A, then turn off
the Main Switch of the
transmitter to cut off
power.
Step6 - Input music ABC into MP3 player.
Step7 - Connect transmitter and MP3
player in Special USB Wire and
Audio-USB Wire.
Disregard
Confirm
M
M
S
S
MS
MS
In Music Control Program
Firing Mode, any press of
button is disable. MP3
player will have TCF200-U
transmit START or STOP
signals to receiver
wirelessly.