Different Detectors for Time Correlated Single Photon Counting G. Rehm DEELS workshop ESRF, 12-13 May 2014 Overview • So far, we’ve been using TCSPC to measure fill pattern (precise charge in filled bunches) more than single bunch purity. • More beamlines are starting to use timing and hybrid bunch, anticipate better bunch purity is required • We are using a PicoHarp 300 with 65536 buckets of 32ps width, 65536 counts depth • We have acquired various single photon detectors over the years – – – – Hamamatsu MCP-PMT R3809U-50 id-quantique SPAD id-100-50 PicoQuant Hybrid PMA X-ray APD: Hamamatsu S2381 with Picosecond Pulse Labs 5530B bias tee and Femto HSA-X-1-40 DEELS, 12-13 May 2014, Different Detectors for TCSPC, G.Rehm 2 MCP-PMT IRF short scale Our measurement with pulsed laser Datasheet 7 10 6 10 5 10 counts 4 10 3 10 2 10 1 10 0 10 -1 -0.5 0 0.5 1 1.5 time [ns] DEELS, 12-13 May 2014, Different Detectors for TCSPC, G.Rehm 3 MCP-PMT IRF long scale 8 10 7 10 6 10 Delayed pulses, physics not understood 5 counts 10 4 10 3 10 Counting deadtime 88ns Afterpulsing 2 10 1 10 0 10 0 50 100 DEELS, 12-13 May 2014, Different Detectors for TCSPC, G.Rehm 150 time [ns] 200 250 300 4 SPAD v MCP-PMT Delayed pulses: ‘diffusion tail’ from red photons Afterpulsing DEELS, 12-13 May 2014, Different Detectors for TCSPC, G.Rehm 5 SPAD white v blue Diffusion tail can be suppressed. No impact on afterpulsing. DEELS, 12-13 May 2014, Different Detectors for TCSPC, G.Rehm 6 SPAD v PMA Afterpulsing after deadtime DEELS, 12-13 May 2014, Different Detectors for TCSPC, G.Rehm 7 SPAD v PMA v X-ray APD DEELS, 12-13 May 2014, Different Detectors for TCSPC, G.Rehm 8 Detector Comparison Detector IRF FW 10e-1 [ps] IRF FW 10e-5 [ps] Dark Counts [1/s] Afterpulsing [%] Cost (Year) Remarks MCP-PMT R3809U50 100 1250 1 0.5 GBP12000 (2005) External HV SPAD id-100-50 170 19000 60 white 800 blue? 1.2 CHF 4200 (2010) Fully integrated, TTL pulse out, 5V supply Hybrid PMA 150 1100 24 0.05 €10000 (2013) Peltier cooled, 12V supply X-ray APD S2381 950 2500 0! 0? GBP55+700+15 50 (2013) 120V supply DEELS, 12-13 May 2014, Different Detectors for TCSPC, G.Rehm 9 Injected v ‘Purified’ Single Bunch DEELS, 12-13 May 2014, Different Detectors for TCSPC, G.Rehm 10 Pile up correction DEELS, 12-13 May 2014, Different Detectors for TCSPC, G.Rehm 11 Summary/Open Issues • Hybrid PMA best visible photon detector, but Xray photon APD is best of all (no news). • Visible light also easy at lowest beam currents, just take out ND filters. • For X-ray APD, currently, need to chose threshold for counting high, otherwise dark counts. Then only 0.1 counts per turn at full current. Sees only scatter from Al window. DEELS, 12-13 May 2014, Different Detectors for TCSPC, G.Rehm 12
© Copyright 2025 ExpyDoc