Phantom and Software for Wedge Angle Determination of dynamic wedges WedgeCheckä Application TM WedgeCheck enables the determination of wedge angles of dynamic (virtual) and mechanical wedges in high energy photon beams as used in radiation therapy. It is very easy to handle and allows to perform the verification measurements in a fast and reliable way. TM The WedgeCheck system consists of a solid acrylic phantom and a special software. The phantom can be attached to the linear accelerator's accessory tray using the appropriate adapter plate. This allows fast and precise positioning of the phantom at any gantry angle. Two ionization chambers can be inserted into the appropriate holes of the phantom. TM is best used with a dual WedgeCheck channel dosemeter (like MULTIDOS or WedgeCheck is a registered trademark of PTW-Freiburg TANDEM) because the dose values from two ionization chambers are necessary for the wedge angle determination. TM Prior to the first operation of WedgeCheck the radiation quality is determined once for each photon energy used. For mechanical wedges the beam quality is measured by taking dose values for each wedge at 10 and 20 cm depth in water. For dynamic wedges the measurement is performed in an open field. The wedge angle determined with the TM system coincides with an WedgeCheck accuracy of ±1% with the results obtained in accordance with IEC 60976. Software WedgeAngleTM TM TM WedgeAngle is a useful software tool included with WedgeCheck . This easy to use Windows TM program automatically calculates wedge angles from WedgeCheck dose values. The dose values may be keyed in or they are automatically recorded via the serial interface of the PTW dual channel dosemeter MULTIDOS or TANDEM. Usage 1. 2. 3. 4. 5. TM Mount the WedgeCheck phantom to the accelerator's accessory tray. Insert two ionization chambers to the phantom's outer measuring positions at 87mm depth. Adjust a field of 20 cm x 20 cm and prepare the accelerator for an irradiation. Irradiate the phantom with a typical treatment dose of 100 MU approx.. TM In th eprogram WedgeAngle select the beam quality used and type in the two dose values to obtain the wedge angle (RS232 link is possible for the PTW dual channel dosemeters MULTIDOS or TANDEM). Ordering Information TM T40013 System WedgeCheck incl. phantom and software (Design according to the specification of the accelerator's accessory tray) Reference TM The procedures and algorithms on which WedgeCheck is based have been developed by Ernst-Ludwig Schmidt and Jürgen Rittler, Westpfalz-Klinikum Kaiserslautern, Germany. Subject to change [D546.139.0/0] 0499-1B Printed on cellulose bleached by a non-polluting method.
© Copyright 2024 ExpyDoc