Table of Contents - EIL Tender portal

Click on the Document Title to go to that section of the document
Table of Contents
Document Number
Rev.
Document Title
Page
Number
2
A096-108-YP-MR1108
A096-108-16-51-SI1108
A096-108-16-51VDR-1108a
A096-108-51-16-DS1108
6-52-0016
A
Pressure Gauges
A
SPECIAL INSTRUCTION TO VENDOR
6
A
VENDOR DATA REQUIREMENT
8
A
DATASHEETS WITH INDEX
10
3
15
6-81-2016
6-78-0001
6-78-0003
3
0
0
Standard specification for pressure, differential pressure and
vaccum gauges
ITP for receiver & pressure gauges
Specification for Quality Mgt. System Requirements from Bidders
Specification for Documentation Requirement from Suppliers
Page 1 of 48
24
28
37
The drawing, design and details given on this format are the property of ENGINEERS INDIA LIMITED. They are merely loaned and on the borrower's express agreement that they will not be reproduced,
copied, exhibited or used, except in limited way permitted by a written consent given by the lender to the borrower for the indended use. EIL-1641-515 Rev.1 A4-210x297
MATERIAL REQUISITION (TOP SHEET)
ITEM DESCRIPTION:
GROUP ITEM CODE
ITEM CATEGORY
Pressure Gauges
DESTINATION :
15KA
I
GAIL PATA(UP)
DELIVERY PERIOD :
DOCUMENT NUMBER
(Always quote the Document Number given below as reference)
A096
108
YP
MR
1108
A
JOB NO
UNIT/
MAIN
COST
DOC.
CODE
SR.NO.
REV
19/02/2014
DATE
16
51
DIVN.
DEPT.
ORIGINATOR
Notes:
1. This page is a record of all Revisions of this Requisition
2. The nature of the Revision is briefly stated in the "Details" column below, the Requisition in its entirety shall be considered for
contractual pupose.
3.Vendor shall note the MR category and shall submit his offer in line with the requirements included in attached
'Instructions to Bidders'
REV
A
BY
DATE
19/02/2014
BC
CHK
APPD
AS
RKG
DETAILS
Issued for Bids
This is a system generated approved document and does not require signature.
Project :
GAIL PC-II
Client :
M/S GAIL (PATA)
ENGINEERS INDIA LIMITED
NEW DELHI
Page 2 of 48
Sheet 1
Of
4
The drawing, design and details given on this format are the property of ENGINEERS INDIA LIMITED. They are merely loaned and on the borrower's express agreement that they will not be reproduced,
copied, exhibited or used, except in limited way permitted by a written consent given by the lender to the borrower for the indended use. EIL-1641-515 Rev.1 A4-210x297
S.NO
DESCRIPTION
TAG NO .
/ ITEM CODE
1
QUANTITY
Design ,engineering,manufacture,procurement of materials and
bought out components, assembly at shop,inspection,testing at
manufacturer's works, packing, delivery, documentation as per the
enclosed EIL standard specifications, instructions to vendors, job
specification, data sheets etc
1.001
000-PI-1831
Pressure Gauge :-Dial- 150mm ,Case 304 SS ,Range 0 - 10 ,DS-
1 Nos
1.002
000-PI-1832
Pressure Gauge :-Dial- 150mm ,Case 304 SS ,Range 0 - 10 ,DS-
1 Nos
1.003
000-PISP-0001
Pressure Gauge :-Dial- 150mm ,Case 304 SS ,Range 0 - 10 ,DS-
1 Nos
1.004
141-PI-1303.
Pressure Gauge :-Dial- 150mm ,Case 304 SS ,Range 0 - 40 ,DS-
1 Nos
1.005
141-PI-1304.
Pressure Gauge :-Dial- 150mm ,Case 304 SS ,Range 0 - 40 ,DS-
1 Nos
1.006
141-PI-1305.
Pressure Gauge :-Dial- 150mm ,Case 304 SS ,Range 0 - 40 ,DS-
1 Nos
1.007
141-PI-1412.
Pressure Gauge :-Dial- 150mm ,Case 304 SS ,Range 0 - 60 ,DS-
1 Nos
1.008
141-PI-2203.
Pressure Gauge :-Dial- 150mm ,Case 304 SS ,Range -1-3 ,DS-
1 Nos
1.009
141-PI-2205.
Pressure Gauge :-Dial- 150mm ,Case 304 SS ,Range 0 - 2.5 ,DS-
1 Nos
5
Supply of two years operation and Maintenance Spares,as per
enclosed instructions to vendor
Unit Rates
6
6.001
Unit Rates of items for addition/deletion purpose,as per the enclosed
instructions to vendor.
1 Lot
Vendors shall quote prices against these items in their price schedule
Vendor to note that the numbers given in square '[]' and curly '{}' brackets are not for their use and
meant for store purpose only.Items shall be tagged as per equipment Tag No. only.
Project :
GAIL PC-II
Client :
M/S GAIL (PATA)
ENGINEERS INDIA LIMITED
NEW DELHI
Page 3 of 48
REV
REQUISITION No.
A096-108-YP-MR-1108
Sheet 2
Of
4
A
The drawing, design and details given on this format are the property of ENGINEERS INDIA LIMITED. They are merely loaned and on the borrower's express agreement that they will not be reproduced,
copied, exhibited or used, except in limited way permitted by a written consent given by the lender to the borrower for the indended use. EIL-1641-515 Rev.1 A4-210x297
LIST OF ATTACHMENTS
S. No.
DOCUMENT TITLE
DOCUMENT NO.
REV
DATE
SHEETS
1
Vendor Data Requirement
A096-108-YP-VD-1108
0
19/02/2014 2
2
Special Instruction to Vendor
A096-108-YP-SI-1108
0
19/02/2014 0
3
Data Sheet Index
A096-108-YP-ID-1108
0
19/02/2014 0
4
Spec. for documentation requirements
from supplier
6-78-0003
0
04/06/2009 12
5
Spec. for quality management sys.req.
from bidders
6-78-0001
0
04/06/2009 9
6
Std spc for Pressure, diff pressure & vacc
Gauges
6-52-0016
3
14/12/2010 8
7
ITP for reciever & pressure gauges
6-81-2016
2
15/07/2011 5
In case of any subsequent revision of MR or PR,only revised sheets of the attachments listed above shall be issued
alongwith the revision.
GENERAL NOTES:
Project :
GAIL PC-II
Client :
M/S GAIL (PATA)
ENGINEERS INDIA LIMITED
NEW DELHI
Page 4 of 48
REV
REQUISITION No.
A096-108-YP-MR-1108
Sheet 3
Of
4
A
Page 5 of 48
Drg/ Doc. Nomenclature
S.No. as per EIL Vendor Data
Requirement
Title
Vendor Drg/ Doc No.
Date of PO:
EIL Originating Department :Instrumentation
Schedule
Category Date of 1st
Review(R)/ Submission
Records(I)
(Rev. 0)
Contact Person(EIL):
Rew
Code
Rew
Code
Ant
Act
Rew
Code
Ant
Act
Rew
Code
Ant
Act
Rew
Code
Ant
Act
Ant
Act
Review Status (Code)
Rev. 1
Rev. 2
Rev. 0
Rev. 3
Actual (Act) Date of submission by vendor
Date of Return (Rew) by EIL
Anticipated (Ant) Date of submission by vendor
Remarks
Form No. EIL-1641-1923 Rev.1
Form
Electronic
(E)/ Print (P)
1. No Comments
2. Proceed with manufacture/ fabrication as per commented document.
Revised document required.
3. Document does not conform to basic requirements as marked.
Resubmit for Review. R: Retained for Reference V: Void
Date of LOI:
PO No.:
Review Status Code:
Status Date:
PR No.:
Contact Person (Name/ Tel/ Fax/ email) :
Item Description:Pressure
Gauges
:
Vendor's Name
Vendor Drawing/ Document Submission Schedule
Client/ Project:M/S GAIL (PATA)/
GAIL PC-II
Engineers India Limited
The drawing, design and details given on this format are the property of ENGINEERS INDIA LIMITED. They are merely loaned and on the borrower's express agreement that they will
not be reproduced, copied, exhibited or used, except in limited way permitted by a written consent given by the lender to the borrower for the indended use. EIL-1651-726 Rev.0 A4210x297
SPECIAL INSTRUCTION TO VENDORS
Part A:
I. BIDDING INSTRUCTIONS
A1. Bidders must follow the following guidelines while submitting their offer. Offers not complying to these guidelines shall be
rejected summarily without any intimation to the Bidder.
a. Furnish quotations only for those items that bidder can supply strictly as per MR specifications and for which they are
approved by EIL.
b. No technical details of any nature shall be included in the offer. If the offer contains any technical deviations or
clarifications or stipulates any technical specifications (even if in line with the MR requirements), the offer shall be summarily
rejected. However, for items where they have entered into MOU with EIL, they may provide a statement that the deviations
are as per MOU with EIL.
c. No correspondence whatsoever shall be entered into or entertained after the bid submission.
d. The submission of prices by the vendor shall be construed to mean that they have confirmed compliance with all technical
specifications of the corresponding item(s).
e. In case of any contradiction between this bidding instructions and any other documents attached with the MR, this bidding
instruction shall govern.
f. Bidder shall submit the price details against each Item No. & Tag No. / Item Code specified in this MR, in the separate
price schedule sheet with unit rate. Accessories if any for a tag shall be indicated in the item summary and the price of the
accessories shall be included in the base price of the tag itself. No information / description, technical or non-technical, other
than what is required shall be filled or submitted. Unit rates of accessories if any, also to be provided separately.
If any change at a later date is required in the range/ selection of accessories due to wrong selection, the same
shall be borne by the vendor.
A2. Bidder is responsible to meet all technical requirements in Material Requisition including Instrument data sheet. If at any
stage, till the completion of order, the offered instruments and its accessories are found unsuitable to meet the specification,
Vendor shall replace the same with suitable items, without any time/Cost implication.
PART-B (Job Specific Requirements)
B1. The Pressure gauges covered in this MR are required for Offsites of GAIL PATA project.
It is responsibility of the vendor to ensure that the Pressure gauges offered by them are suitable for the specified process
conditions for this application.
B2. Vendor shall carefully go through the MR and submit the offer strictly in line with the requirements spelled out in the MR.
Following shall be strictly complied with:
a) No detail technical offer is required. Offer shall be containing the Item No. & Tag. No. only. NO OTHER DESCRIPTION IS
REQUIRED AS PER MR AND THESE OR OTHER DESCRIPTION DETAILS SHALL NOT BE INDICATED IN THE OFFER.
Any references or details other than the item no. and tag no. shall be ignored, during evaluation.
b) Offers will be evaluated based on the item no., tag no., compliance statement and deviation list (if any). During evaluation,
only these are required to be submitted along with the offer. Any other technical information other than the above will be
completely ignored.
c) Any offer, not complying to above will be liable for rejection.
B3. The selection of pressure gauge with all its accessories shall be the responsibility of vendor based on Standard
Specification for Receiver and Pressure Gauges (6-52-0016 Rev.3).
B4. All the items supplied by vendor shall be subject to inspection at instrument manufacturer's works. As a minimum, the
inspection and testing requirements as per Inspection Test plan for Receiver & Pressure gauges (6-81-2016 Rev.2) and
Standard Specification for Receiver and Pressure Gauges (6-52-0016 Rev.3) shall also be adhered to.
B5. Vendor shall quote separately for spare parts for 2 years normal operation and maintenance spares as per clause no.
1.2.5 of Standard Specification for Receiver and Pressure gauges (6-52-0016) in the offer and furnish the list for the same
along with the offer.
B6. Unit rates :
0
19/02/2014 BC
AS
RKG
REQ. NO.
: A096-108-YP-MR-1108
ORDER NO. :
REV
DATE
BY CHKD APPVD VENDOR
ENGINEERS INDIA LIMITED
NEW DELHI
Page 6 of 48
:
PLANT :
GAIL PC-II
UNIT
108
CLIENT
:
Page 1 Of 2
M/S GAIL (PATA)
SPECIFICATION
A096-108-YP-SI-1108
REV
0
The drawing, design and details given on this format are the property of ENGINEERS INDIA LIMITED. They are merely loaned and on the borrower's express agreement that they will
not be reproduced, copied, exhibited or used, except in limited way permitted by a written consent given by the lender to the borrower for the indended use. EIL-1651-726 Rev.0 A4210x297
SPECIAL INSTRUCTION TO VENDORS
Vendor shall quote unit rates for Gauge saver, siphon and all accessories for any addition/Deletion purpose.
B7. For Remote mounted pressure gauges, all the mounting accessories shall be provided by the vendor.
B8. Gauge Pointer shall have external micrometer adjustment for gauge zero adjustment.
B9. Wherever Screwed Bezel Ring is specified in the data sheet for SS Casing Material, Bayonet type is also acceptable.
B10. Syphon, wherever indicated shall be of SS316 material unless specified in datasheet. Specification of syphon shall be
as per enclosed drawing A096-110-16-51-DW-1100
B11. IBR requirements:
Syphon shall be tested and test certificate in Form-III C duly certified by the local Boiler Inspecting Authority or his authorized
representative.
Price for all the testing & certification requirement shall be included as part of base price.
B12. Vendor shall furnish soft copies of all as built drawings and datasheets in Autocad/ MS excel formats for loading in
Owners's Documentation Node.
B13. SITE CONDITIONS:
The Pressure Gauges and accessories covered in the MR shall be suitable for unprotected installation in Hot, Humid and
Corrosive environment having following ambient condition.
The site environmental conditions at Pata, Uttar Pradesh are as follows:
Ambient temperature (Max. / Min): 46 deg. C / (-) 2.2 deg. C.
Relative humidity : 90% @ Max. Temp.
Maximum Record Rainfall : 120 mm in 1 hour.
0
19/02/2014 BC
AS
RKG
REQ. NO.
: A096-108-YP-MR-1108
ORDER NO. :
REV
DATE
BY CHKD APPVD VENDOR
ENGINEERS INDIA LIMITED
NEW DELHI
Page 7 of 48
:
PLANT :
GAIL PC-II
UNIT
108
CLIENT
:
Page 2 Of 2
M/S GAIL (PATA)
SPECIFICATION
A096-108-YP-SI-1108
REV
0
The drawing, design and details given on this format are the property of ENGINEERS INDIA LIMITED. They are merely loaned and on the borrower's express agreement that they will
not be reproduced, copied, exhibited or used, except in limited way permitted by a written consent given by the lender to the borrower for the indended use. EIL-1651-726 Rev.0 A4210x297
VENDOR DATA REQUIRMENT
With
Proposal
(Prints)
Description
1.
Dimensional details with mounting details and model number
2.
Connections by purchase(Piping,Electrical Etc.)
3.
Wiring diagrams
4.
Parts list
5.
Recommended spare parts list(for two years operation )
6.
Installation, Operation and maintenance manual
7.
Nomograph and sizing calculations
8.
Test certificates
9.
Certificate from statutory body
10.
Assembly details
11.
Catalogues in english
12.
Testing and Inspection procedures
AFTER PURCHASE ORDER
Prints
Date Needed
6
6
6W
6W
Final
Documentation
/ As Built
6(W/S)
6
6(W/S)
6(W/S)
6
6W
13. Final Documentation (Editable format in CD)
0
19/02/2014 BC
AS
RKG
REQ. NO.
DATE
BY
CHKD APPVD VENDOR
ENGINEERS INDIA LIMITED
: A096-108-YP-MR-1108
NEW DELHI
Page 8 of 48
GAIL PC-II
UNIT
108
CLIENT
Page 1 Of 2
:
PLANT :
:
6(W/S)
6(W/S)
6(W/S)
ORDER NO. :
REV
6(W/S)
6(W/S)
M/S GAIL (PATA)
SPECIFICATION
A096-108-YP-VD-1108
REV
0
The drawing, design and details given on this format are the property of ENGINEERS INDIA LIMITED. They are merely loaned and on the borrower's express agreement that they will
not be reproduced, copied, exhibited or used, except in limited way permitted by a written consent given by the lender to the borrower for the indended use. EIL-1651-726 Rev.0 A4210x297
VENDOR DATA REQUIRMENT
NOTES :
1.
Fold all drawings to 216mm X 279mm and roll transparencies.
2.
Vendor to provide all printed matter to ENGINEERS INDIA LIMITED (EIL).
ATTENTION Vendor Print Control,
EIB-10th Floor,
1, Bhikaiji Cama Place,
LEGEND:
Categories preceeded with * will be approved for fabrication by Engineers India Limited.
The remaining drawings are needed for information only.
A/C = As compiled A/R = As required W/S = With shipment W = Weeks
IMPORTANT
While submittimg drawings and documents for review as indicated in vendor data requirement,
vendor must ensure the following :
1.
A blank space measuring 75 mm W x 38 mm H shall be provided on all vendor drawings
(on the front side) for marking review codes etc. by ENGINEERS INDIA LIMITED.
2.
The review of the drawings shall be done as applicable, under the following review codes :
a) Review Code 1 : No Comments.
b) Review Code 2 : Proceed with manufacture / fabrication as per commented drawing.
Revised drawing required.
c) Review Code 3 : Document does not conform to the basic requirements as marked.
Resubmit for review.
3.
Review of the vendor drawings by EIL would be only to check compatibility with basic design and
concepts and would in no way absolve the manufacturer / fabricator of his responsibility to meet the
applicable codes, specifications and statutory rules and regulations.
4.
For drawings / documents indicated as FOR INFORMATION in the vendor data requirement,
vendor must clearly mark FOR INFORMATION ONLY on the submitted drawings / documents.
0
19/02/2014 BC
AS
RKG
REQ. NO.
: A096-108-YP-MR-1108
ORDER NO. :
REV
DATE
BY
CHKD APPVD VENDOR
ENGINEERS INDIA LIMITED
NEW DELHI
Page 9 of 48
:
PLANT :
GAIL PC-II
UNIT
108
CLIENT
:
Page 2 Of 2
M/S GAIL (PATA)
SPECIFICATION
A096-108-YP-VD-1108
REV
0
S.NO.
EIL-1651-593 Rev.1 A4-210x297
The drawing, design and details given on this format are the property of ENGINEERS INDIA LIMITED. They are merely loaned and on the borrower's express agreement that they will not be reproduced,
copied, exhibited or used, except in limited way permitted by a written consent given by the lender to the borrower for the indended use.
DATA SHEET INDEX
DESCRIPTION
DATA SHEET NO.
REV
DATE
1
Pressure Gauge
A096-000-YP-DS-1101
0
19/02/2014
2
Pressure Gauge
A096-141-YP-DS-1105
0
19/02/2014
0
19/02/2014
BC
RKG
RKG
REQ. NO.:
A096-108-YP-MR-1108
Page 1 Of 1
ORDER NO.:
REV
DATE
BY
CHKD APPVD VENDOR:
ENGINEERS INDIA LIMITED
NEW DELHI
Page 10 of 48
PLANT
GAIL PC-II
UNIT
108
CLIENT
M/S GAIL (PATA)
SPECIFICATION
REV
A096-108-YP-ID-1108
0
The drawing, design and details given on this format are the property of ENGINEERS INDIA LIMITED. They are merely loaned and on the borrower's express agreement that they will not be
reproduced, copied, exhibited or used, except in limited way permitted by a written consent given by the lender to the borrower for the indended use. EIL-1651Rev. A4-210x297
Pressure Gauge
1.
Type
Direct Read
17. Connection Size
1/2" NPT (M)
2.
Mounting
Local
18. Connection Location
Bottom
3.
Dial Size
150mm
19. Diaphram Seal
Not Required
4.
Dial Colour
White
20. Diaphram Type
5.
Case Material
304 SS
21. Wetted Parts Material
Bezel Ring
Screwed/ Bayonet
22. Others Material
7.
Over Range Protection
30% of Full Scale
23. Process Connection
8.
Blow Out Protection
Required
24. Size & Rating
9.
Window Material
Shatter Proof Glass
25. Facing & Finish
10.
Enclosure Type
IP-65
26. Capillary Length
11.
Pressure Element
Bourdon
27. Capillary Material
12.
Element Material
SS 316
28. Armour Type
Socket Material
SS 316
29. Material
Accuracy , Full Scale
±1%
30. Flush/Fill Connection
15.
Zero Adjustment
Micrometer Pointer
16.
Movement
316 SS
6.
13.
14.
Options :
Size
a) Pulsation Dampener
b) Syphon C Type
c) Pressure Limit Valve
d) Liquid Filled Casing
e) Vaccum Protection
f) Spacer ring (drip ring)
g) Gasket and Backup Flanges
h) Mounting Accessories for 2" NB Pipe
i) Solid Front
Notes :
1. The Maximum pressure and temperature indicated in the datasheet are the design pressure and temperature respectively.
Sheet
0
19/02/2014
NS
RKG
REV
DATE
BY
CHKD
RKG
APPVD VENDOR
ENGINEERS INDIA LIMITED
NEW DELHI
Page 11 of 48
REQUISITION NO : A096-108-YP-MR-1108
ORDER NO.
:
:
PLANT : GAIL PC-II
UNIT
LEGEND
:
1
Of
2
¤ Hold
* By Vendor
^ Data Revised
SPECIFICATION
REV
: 000
CLIENT: M/S GAIL (PATA)
A096-000-YP-DS-1101
0
Pressure Gauge
Rev.
Tag No
Pressure
Range
The drawing, design and details given on this format are the property of ENGINEERS INDIA LIMITED. They are merely loaned and on the borrower's express agreement that they will not be
reproduced, copied, exhibited or used, except in limited way permitted by a written consent given by the lender to the borrower for the indended use. EIL-1651Rev. A4-210x297
Oper.
Temperature
Max.
Unit
Fluid
Service
Options
Maximum
0 000-PI-1831
0 - 10
5.8
9 kg/cm²(g)
65 °C
4"-OWS-A96A
a,h
0 000-PI-1832
0 - 10
5.8
9 kg/cm²(g)
65 °C
4"-OWS-A96A
a,h
0 000-PISP-0001
0 - 10
5.8
9 kg/cm²(g)
65 °C
a,h
Sheet
0
19/02/2014
NS
RKG
REV
DATE
BY
CHKD
RKG
APPVD VENDOR
ENGINEERS INDIA LIMITED
NEW DELHI
Page 12 of 48
REQUISITION NO : A096-108-YP-MR-1108
ORDER NO.
:
:
PLANT : GAIL PC-II
UNIT
LEGEND
:
2
Of
2
¤ Hold
* By Vendor
^ Data Revised
SPECIFICATION
REV
: 000
CLIENT: M/S GAIL (PATA)
A096-000-YP-DS-1101
0
The drawing, design and details given on this format are the property of ENGINEERS INDIA LIMITED. They are merely loaned and on the borrower's express agreement that they will not be
reproduced, copied, exhibited or used, except in limited way permitted by a written consent given by the lender to the borrower for the indended use. EIL-1651Rev. A4-210x297
Pressure Gauge
1.
Type
Direct Read
17. Connection Size
1/2" NPT (M)
2.
Mounting
Local
18. Connection Location
Bottom
3.
Dial Size
150mm
19. Diaphram Seal
Not Required
4.
Dial Colour
White
20. Diaphram Type
5.
Case Material
304 SS
21. Wetted Parts Material
Bezel Ring
Screwed/ Bayonet
22. Others Material
7.
Over Range Protection
30% of Full Scale
23. Process Connection
8.
Blow Out Protection
Required
24. Size & Rating
9.
Window Material
Shatter Proof Glass
25. Facing & Finish
10.
Enclosure Type
IP-65
26. Capillary Length
11.
Pressure Element
Bourdon
27. Capillary Material
12.
Element Material
SS 316
28. Armour Type
Socket Material
SS 316
29. Material
Accuracy , Full Scale
±1%
30. Flush/Fill Connection
15.
Zero Adjustment
Micrometer Pointer
16.
Movement
316 SS
6.
13.
14.
Options :
Size
a) Pulsation Dampener
b) Syphon C Type
c) Pressure Limit Valve
d) Liquid Filled Casing
e) Vaccum Protection
f) Spacer ring (drip ring)
g) Gasket and Backup Flanges
h) Mounting Accessories for 2" NB Pipe
i) Solid Front
Notes :
1. The Maximum pressure and temperature indicated in the datasheet are the design pressure and temperature respectively.
Sheet
0
19/02/2014
PK
RKG
REV
DATE
BY
CHKD
RKG
APPVD VENDOR
ENGINEERS INDIA LIMITED
NEW DELHI
Page 13 of 48
REQUISITION NO : A096-108-YP-MR-1108
ORDER NO.
:
:
PLANT : GAIL PC-II
UNIT
LEGEND
:
1
Of
2
¤ Hold
* By Vendor
^ Data Revised
SPECIFICATION
REV
: 141
CLIENT: M/S GAIL (PATA)
A096-141-YP-DS-1105
0
Pressure Gauge
Rev.
Tag No
Pressure
Range
Oper.
The drawing, design and details given on this format are the property of ENGINEERS INDIA LIMITED. They are merely loaned and on the borrower's express agreement that they will not be
reproduced, copied, exhibited or used, except in limited way permitted by a written consent given by the lender to the borrower for the indended use. EIL-1651Rev. A4-210x297
0 141-PI-1303.
Temperature
Unit
Max.
0 - 40
Fluid
Service
Options
Maximum
29.1 kg/cm²(g)
65 °C
C2/C3 LIQU 8"-P-141-1302-B4A-IC
a,h
Notes: 1. Operating pressure varies from 20.75-25 kg/cm2.
2. Design temperature is -45/65.
0 141-PI-1304.
0 - 40
65 °C
C2/C3 LIQU 8"-P-141-1303-B4A-IC
a,h
0 141-PI-1305.
Notes: 1. Operating presure varies from 20.75-25 kg/cm2.
2. Design temp. is -45/65.
0 - 40
29.1 kg/cm²(g)
29.1 kg/cm²(g)
65 °C
C2/C3 LIQU 8"-P-141-1304-B4A-IC
a,h
0 141-PI-1412.
Notes: 1. Operating presure varies from 20.75-25 kg/cm2.
2. Design temp. is -45/65.
0 - 60
32.6
45 kg/cm²(g)
65 °C
ETHYLENE 8"-P-141-1411-B4A-IC
a,h
0 141-PI-2203.
Notes: 1. Design temperature is -45/65.
-1-3
3.5 kg/cm²(g)
175 °C
HC VAPO
18"-FL-141-2201-A2K
65 °C
HC VAPO
BLOW DOWN DRUM( a,c,h
a,e,c,h
Notes: 1. Operating pressure varies from 0.1-1.7 kg/cm2g.
2. Design temperature is -150/175.
0 141-PI-2205.
0 - 2.5
3.5 kg/cm²(g)
Notes: 1. Operating pressure varies from 0.1~1.7 kg/cm2g.
2. Design temperature: (-)150/65 deg C.
Sheet
0
19/02/2014
PK
RKG
REV
DATE
BY
CHKD
RKG
APPVD VENDOR
ENGINEERS INDIA LIMITED
NEW DELHI
Page 14 of 48
REQUISITION NO : A096-108-YP-MR-1108
ORDER NO.
:
:
PLANT : GAIL PC-II
UNIT
LEGEND
:
2
Of
2
¤ Hold
* By Vendor
^ Data Revised
SPECIFICATION
REV
: 141
CLIENT: M/S GAIL (PATA)
A096-141-YP-DS-1105
0
Page 15 of 48
Page 16 of 48
Page 17 of 48
Page 18 of 48
Page 19 of 48
Page 20 of 48
Page 21 of 48
Page 22 of 48
Annexure 1 to
MATERIAL OF CONSTRUCTION
S. No.
Item
Specified Material of
STANDARD SPECIFICATION NO.
6-52-0016 Rev. 3
Page 1 of 1
Alternate Material of Construction
Construction
1.
Sensing Element
SS 316
SS 316L, SS 316Ti
2.
Socket
SS 316
SS 316L, SS 316Ti
SS 304
SS 304L, SS 316
3.
Case
Cast Aluminium
SS 316Ti, SS 316L,SS
4.
Capillary
SS
SS 304, SS316, SS 304L,
SS 316L, SS 316Ti
5.
Diaphragm
SS 316
SS 316L, SS 316Ti
SS
SS 302, SS 304, SS 304L,
SS 316, SS 316L, SS 316Ti
Format No. 8-00-0001-F1 Rev. 0
Page 23 of 48
Copyrights EIL – All rights reserved
Copyright EI L — Al l rightsreserved
0• AadLd- 1000-00-8'0N ImuLiod
cr
O
O
ro
D
4.)
O
Page 24 of 48
iy
uogrivawaidw! Jo; parissi
panss!-a.0 pue pOSIA3•H
panss! ag pue pas!nal
0
fP
oa
£*Aa21 910Z-I8-9
STANDARD SPECIFICATION NO.
()
4
Page 25 of 48
'C$
r=,)
2
.o.
..,
-.,„:,,,O
CI
44
:,)
O $),)
o.-,
o
•
yy
o
-
Cm
$. <-,
„O
4)-
(4 ,__,
,—
› c.)
c
-.
«
's
lo
0
oo'..'
CD
v)
o
= n(
Q.,
et)
g°
C) Crg
co
1-r1 94 ci'
ro 6
O.
OD
5'
.. o
O
ODP
"Zh3),)
n
.
,...r)
.2.5
''—ocAn
O
o c). ,,scx,
.1. ■-t''•
PD CAn0
,•-.o .C) CD
• ,
CD or)
CM
4
—
O
O
to
O
N'
op
S=L- cir;'
r)
,00
-1
7:(1)
(1),
...
,.0
-.,v,
.8. ,2,■-t- CD
•-r-
o,
C..
Cm
,--t- v)
et,
,-, o°
H—H
roOnH
V,
CI, er,
)-s)0
_
,.4 ..4. .,..
.=, 4 :),,,
(,) .0
..0
,do-,,,
,
op
•o.. (,) ,-0
'Cl ■-0 o)
CD •
CL.,CD.C1-cl.,
0
na5 "-o-noo-,--,'-do-o
,
..., 0s)orp
C2A"'-‘:/(1)T2IncAccu)nc,
.(2)..5
...-s)
2M
cp.
tr9,,E,.,m
<
-.
c,),-,
n
(.5 H v) 0
ci.q
nO
O) O.)
c.)
,«:, w-
"
o
m" ,
c.
'A,
, cn
sr.
):
,..-..
= 9.,.
-., g)
@-.-..i3))19 4
( F'
D'
~rimtnnn
.<H ,.--3:) ,-ci ,-0 ,-0.-0-cizz4
cci)o
6_9
c.- ,
Ho O c40-,
■-*(D ro
..?
-.
=
.
..,.,1;
x'
'-t:J-6.'"ciCan4›,
94
CD
.-t
cxo
O
<-)
.7,1xximnnn
r- = A 5
,,,.' ,
z,,,,
H
O
aa
STANDARD SPECIFICATION NO.
Inspection StandardsCommittee
0'AedLJ- 1000-00-8 'oN ;eulioj
Copyright EIL — Allrightsreserved
suopuptaaqqv
VidfID 'D'S
11
NIVId1S31
STANDARD SPECIFICATION NO.
£'AaR 910Z-18-9
:adops o.i
This InspectionandTestPlancoverstheminimumtestingrequirements for Industrial TypePressure Receiver Gauges.
PO/PR &Standardsreferred there in /Job specifications / Approved documents.
X
c,
0
r)
,r)
—,
&)
cA
0
MaterialTest
Certificates /
Testrecords
Page 26 of 48
i
7:1
Z
:
i
Visual
Dimensional
Calibration
OverPressure
Vacuumtest(if applicable)
Hydrotestonsnubbers/gaugessavers(as
a• licable)
Testrecords
o
-totn..
up
Calibration,Overpressure, Hysteresis, Accuracy
■
-3
co
cl,
,--,
••••••
0
0
Final Inspection
Chemical and Mechanical Properties
SCOPE OF INSPECTION
SUB
SUPPLIER EIL/TPIA
SUPPLIER
0
0
4:,
0
.-.
Assemblyand calibration
of pressuregauge
Final Inspection
tri
Inprocess Inspection
r)
t■.)
--,
IncomingMaterial like
Pressure Element,Cases,
Glass, Flanges,gauge
savers,snubber,syphon
etc.
e)
z
z CA
0
i....■
::.
tJ
Z:::1
Material Inspection
(,-)
.—■
Procedures
QUANTUM
OF CHECK
paniaseJ siy 6P IIV— 113414 60doo
STAGE/ ACTIVITY
t■à
0
3.0 INSPECTION AND TEST REQUIREMENTS:
0.Aed L3- 1000-00-9 '0N lewiod
UD
NIVIdIS31
STANDARD SPECIFICATION NO.
••••
.,,
r
,-,4
r.
x
t.1
r)
o
it
UD
o
SUPPLIER
x
,,,
,,,
,
o
Compilationof Inspectionreports,drawings,etcas
perVDR / PR
EOF INSPECTION
z
i.)
Final Document
submission
Supplier Test
Records / Type
testcertificate /
IC
Final data
folder
/Completeness
certificate
,
—
Documentationand IC
Reviewsof Intemal TestReports
Degreeof protectioncertificate forenclosure
IC issuance
SUB
SUPPLIER
.
O
Documentationand IC
tri
o
g
O
Painting
UD
Type Test
Certificates
.
i‘J
Typetestson Assembled
Pressure Gauges
UD
Typetests:
Test for influenceof Temperature
Onesample
Shock test
permodel &
range
Endurancetest
Weather Proof Constructionof housing
CHARACTERISTICS
cp
c:>
0 t'''
t=1
£*Aall9I0Z-I8-9
QUANTUM
OF CHECK
STAGE/ ACTIVITY
•••
Page 27 of 48
(D
"C"). •
s).)
s).)
Cr
(D
17).
O
c_
cn
ro
O
—•
rt)
s)..)
v)
.cs
CD
.th•
..
(D
cr
cn
•
er)
(D
cn
(/)
o
-e
CD
Cl.
Cl.
1=0
0
S=0
CD
Cl.
Ct.
Cl)
>
=
k.<
cr)
r)))
E.
cr
co
•-•1
CD
P,)
cp
rt)
CD
C")
CFc
ro
r)
—•
s),) • &,
1)
.-4.)
CD
rD
crc:
0 rD
c7)
CD
•••1 7)"
O
■
—■
:(alqumiddu sV)SaIONI
L3 0
o3wei. ;"oN9-00-000 1. -"oAl
CopyrightEI L—All rightsreserved
Page 28 of 48
Page 29 of 48
Page 30 of 48
Page 31 of 48
Page 32 of 48
Page 33 of 48
Page 34 of 48
Page 35 of 48
Page 36 of 48
Page 37 of 48
Page 38 of 48
Page 39 of 48
Page 40 of 48
Page 41 of 48
Page 42 of 48
Page 43 of 48
Page 44 of 48
Page 45 of 48
Page 46 of 48
Page 47 of 48
Page 48 of 48