DATASHEET_RMU485_Cat.. - FF

A
U
T
O
L
O
G
®
D
A
T
A
S
H
E
E
T
AutoLog®
AutoLog® Cathodic Protection RMU 485
S O P H I S T I C A T E D®A U T O M A T I O N
Complete remote
monitoring &
controlling solutions
for Cathodic
Protection.
Cathodic protection
system prevents
from corrosion.
Introduction
AutoLog® Cathodic Protection
RMU 485 gives compact and
high specification solution for
cathodic protection of pipeline.
AutoLog® RMU 485
AutoLog Cathodic Protection
RMU 485 can communicate
using Modbus RTU protocol
over RS-485 interface.
AutoLog Cathodic Protection
RMU 485 is based on similar
hardware as WRMU (Radio
modem version) which is used
all over Saudi-Arabia by Saudi
Aramco.
RMU 485
communicate
through RS-485
network.
SCADA
RS-485
AutoLog Cathodic Protection
RMU is based on well proven
AutoLog technology. FFAutomation has manufactured
AutoLog automation products
since 1976. RTU devices are
our main business area.
• 5 surge protected analog inputs
designed for Cathodic Protection
rectifier monitoring
• Local HMI
• Cabin temperature monitoring
• RS-485 Modbus communication
RMU = Remote Monitoring Unit
PLC / RMU
Wireless
Telemetry
The world's biggest oil and gas producer companies trust their
production on AutoLog RTU devices.
.
List of AutoLog RTU references can be found from our web page.
www.ff-automation.com
AutoLog CP RMU 485
Manufactured
Manufactured by
by
FF-Automation
FF-Automation
THE AUTOLOG®FAMILY
AUTOLOG®P L C AUTOLOG®G S M
AUTOLOG®OEM
AUTOLOG®R T U AUTOLOG®T E T R A AUTOLOG®H M I
A
U
T
O
L
O
G
D
®
A
T
A
S
H
E
E
AutoLog®
AutoLog® Cathodic Protection RMU 485
PLC
Model
AutoLog 10SP
Analog Inputs
5 pcs
16-bit resolution, 0-800mVDC,
0-3.2VDC, 0-50VDC, 0-100VDC.
0-x Amperes with external shunt
resistor. Input ranges can be
selected pointwise using software.
Surge protected, opto-isolated. In
addition.
Temperature
sensors
2 on-board temperature sensors
Digital inputs
4 pcs
12/24 VDC / max. 8 mA / PNP /
opto-isolated
Digital outputs
4 pcs
12/24VDC / max. 1A / NPN / optoisolated
Serial ports
2 pcs, Modbus master / slave
I2C port
For HMI keypad & display
Data Logging
16 time-stamped measurements
x 3000 records
Operating
temperature
-30°C…+60°C
Storage
temperature
-40°C…+80°C
Power supply
12 / 24 VDC or 10/18VAC max.
5VA, voltage drop alarm
UPS
12VDC, voltage drop alarm
Programming
Remote through RS-485 network
or locally using programming cable
Communication
RS-485
Modbus RTU (selectable speed)
OPTINAL: TCP/IP
Modbus TCP protocol (needs
optional converter)
SCADA
Software
Web Studio SCADA / other
SCADAs
Web support
In Web Studio SCADA all main
control room views can be seen
remotely from any PC in Intranet.
Configurable user levels and
firewall security.
AutoLog® Cathodic Protection RTU
Systems are operating in wide areas
WWW.FF–AUTOMATION.COM
FFFF-AUTOMATION
Erä
Eräkuja 2, 01600 Vantaa, Finland
tel. +358 9 530 6310
fax +358 3 5846 711
e-mail: info@[email protected]
Web: www.ffwww.ff-automation.com
T