48VG ---A Performancet 16 SEER 2---Stage Packaged Air Conditioner and Gas Furnace System with PuronR (R ---410A) Refrigerant Single and Three Phase 2 to 5 Nominal Tons (Sizes 24---60) Product Data heating/cooling size combinations with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Innovative Unit Base Design On the inside a high--tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging. Convertible duct configuration Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow and includes two horizontal duct covers. Downflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode. Efficient operation A09033 Fig. 1 -- Unit 48VG--A Single--Packaged Products with Energy--Saving Features and PuronR refrigerant. S 15.0 to 16.0 SEER S 12.0 -- 12.5 EER S Up to 80.4% AFUE S Meets Energy Star requirements S Direct Spark Ignition S Factory--Installed TXV S Multi--speed ECM Blower Motor--Standard S Sound Levels as low as 72dBA S Two Stage Cooling S Two Stage Heating (208/230 VAC models) S Dehumidification Feature FEATURES/BENEFITS One--piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance. Puron Environmentally Sound Refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. Puron refrigerant is in service in millions of systems proving highly reliable, environmentally sound performance. Easy Installation Factory--assembled package is a compact, fully self--contained, combination gas heating/electric cooling unit that is prewired, pre--piped, and pre--charged for minimum installation expense. These units are available in a variety of standard and optional High--efficiency design offers SEER (Seasonal Energy Efficiency Ratios) of 15.0 to 16.0, 12.0 to 12.5 EER, and AFUE (Annual Fuel Utilization Efficiency) ratings as high as 80.4%. Energy--saving, direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are furnished with natural gas controls. A low--cost field installed kit for propane conversion is available for all units. 48VGN--A units are dedicated Low NOx units designed for California installations. These models meet the California maximum oxides of nitrogen (NOx) emissions requirement of 40 nanograms/joule or less as shipped from the factory and MUST be installed in California Air Quality Management Districts and wherever a Low NOx rule exists. Durable, dependable components Compressors have two stages of cooling and are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection. Monoport inshot burners produce precise air--to--gas mixture, which provides for clean and efficient combustion. The large monoport on the inshot (or injection type) burners seldom, if ever, requires cleaning. All gas furnace components are accessible in one compartment. Turbo--tubulart heat exchangers are constructed of aluminized steel for corrosion resistance and optimum heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air. In addition, dimples located on the heat exchanger walls force the hot gases to stay in close contact with the walls, improving heat transfer. Stainless steel heat exchanger available as factory installed option. 1 48VG -- A Multi--speed ECM Blower Motor is standard on all 48VG--A models. Direct--drive PSC (Permanent Split Capacitor) condenser--fan motors are designed to help reduce energy consumption and provide for cooing operation down to 40_F (4.4_C) outdoor temperature. Motormasterr II low ambient kit is available as a field--installed accessory. Thermostatic Expansion Valve -- A hard shutoff, balance port TXV maintains a constant superheat at the evaporator exit (cooling cycle) resulting in higher overall system efficiency. Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier. High and Low Pressure Switches provide added reliability for the compressor. Indoor and Outdoor coils are computer--designed for optimum heat transfer and efficiency. The indoor coil is fabricated from copper tube and aluminum fins and is located inside the unit for protection against damage. The outdoor coil is internally mounted on the top tier of the unit. Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 72dBA. Dehumidification Feature This unit has independent fan speeds for low stage cooling and high stage cooling. In addition, 208/230 VAC models have the field--selectable capability to run an enhanced dehumidification (’DHUM’) speed on high stage cooling (as low as 320CFM per ton). Coupled with the improved dehumidification associated with low stage cooling, the DHUM speed allows for a complete dehumidification solution independent of cooling stage. 208/230 VAC models also have independent fan speeds for low stage gas heating and high stage gas heating. The dehumidification control must open the control circuit on humidity rise above the dehumidification set point. NOTE: The enhanced dehumidification feature on high stage cooling does not support use of an economizer. Heating S Reliable direct spark ignition system S Two--speed PSC inducer motor with ball bearings (208/230 VAC models) S Low stage heating delivers 65% of high--stage capacity (208/230 VAC models) Easy to service cabinets provide easy 3--panel accessibility to serviceable components during maintenance and installation. The basepan with integrated drain pan provides easy ground level installation with mounting pad. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3/4--in. (19.05 mm) wide perimeter flange makes frame mounting on a rooftop easy. Standard horizontal metal duct covers with insulation come with the unit and cover the horizontal duct openings. These can be left in place if the units are converted to downflow. Integrated Gas Control (IGC) board provides safe and efficient control of heating and simplifies trouble--shooting through its built--in diagnostic function. Cabinets are constructed of heavyduty, phosphated, zinc--coated prepainted steel capable of withstanding 500 hours in salt spray. Interior surfaces of the evaporator/heat exchanger compartment are insulated with foil--faced insulation, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating, Refrigeration and Air Conditioning Engineers 62.2.) The sloped drain pan minimizes standing water in the drain. An external drain is provided. Louvered grille provides hail and vandalism protection for the coil. TABLE OF CONTENTS Features/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Model Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . 3 AHRI Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5---6 Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Base Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 8---9 Accessory Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12---24 Typical Piping and Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Typical Wiring Schematics . . . . . . . . . . . . . . . . . . . . . 52---61 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 63---64 2 MODEL NUMBER NOMENCLATURE --- 48VG A 24 040 3 0 --- --Options GP --- Base unit with tin plated indoor coil hairpins and Stainless Steel HX (Single Phase Only) GS --- Stainless Steel HX TF --- Filter Rack TP --- Base unit with tin plated indoor coil hairpins (Single Phase Only) Type of Unit 48VG --- Two Stage Packaged Air Conditioner and Gas Furnace System See Price Page for full list of factory options. Only used if ordering an option Low NOx Indicator --Standard N --- Low NOx Minor Series Nominal Cooling Capacity 24 --- 2.0 Tons 30 --- 2.5 Tons 36 --- 3.0 Tons 42 --- 3.5 Tons 48 --- 4.0 Tons 60 --- 5.0 Tons Electrical Supply 3 --- 208/230--- 1--- 60 5 --- 208/230--- 3--- 60 6 --- 460--- 3--- 60 48VG -- A Major Series Heat Input Size (Btuh) 040 --- 40,000 060 --- 60,000 090 --- 90,000 115 --- 115,000 130 --- 130,000 Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. 3 AHRI* CAPACITIES 48VG -- A Cooling Capacities and Efficiencies Unit Model 48VG-A Nominal Tons Standard CFM (High / Low Stage) 24 30 36 42 48 60 2 2-1/2 3 3-1/2 4 5 800 / 600 1000 / 750 1200 / 900 1400 / 1050 1600 / 1200 1750 / 1200 Net Cooling Capacities - Btuh (High Stage) 23000 29000 35400 42000 47500 57000 LEGEND dB--- Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP---Coefficient of Performance * Air Conditioning, Heating & Refrigeration Institute. **At “A” conditions---80_F (26.7_C) indoor db/67_F (19.4_C) indoor wb & 95_F (35_C) outdoor db. { Rated in accordance with U.S. Government DOE Department of Energy) test procedures and/or AHRI Standards 210/240. EER @A** SEER† 12.0 12.0 12.5 12.5 12.3 12.3 15.0 15.0 16.0 16.0 16.0 16.0 Notes: 1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80F (26.7_C) db, 67F wb (19.4_C) indoor entering---air temperature and 95F db (35_C) outdoor entering---air temperature. 2. Before purchasing this appliance, read important energy cost and efficiency information available from AHRIdirectory.org. Heating Capacities and Efficiencies 208/230 VAC Models UNIT 48VG-- A HEATING INPUT (BTUH) HIGH/LOW OUTPUT CAPACITY (BTUH) HIGH / LOW TEMPERATURE RISE RANGE HIGH F (C) TEMPERATURE RISE RANGE LOW F (C) AFUE (%) 24040 30040 40,000 / 26,000 32,000 / 21,000 20--50 (11--28) 15--45 (8--25) 78 24060 30060 36060 42060 60,000 / 39,000 49,000 / 31,000 25--55 (14--31) 25--55 (14--31) 78.6 36090 42090 48090 60090 90,000 / 58,500 74,000 / 47,000 35--65 (19--36) 35--65 (19--36) 79.2 48115 60115 115,000 / 75,000 93,000 / 61,000 30--60 (17--33) 30--60 (17--33) 80.1 48130 60130 130,000 / 84,500 103,000 / 68,000 35--65 (19--36) 35--65 (19--36) 80.0 LEGEND AFUE --- Annual Fuel Utilization Efficiency NOTE: Before purchasing this appliance, read important energy cost and efficiency information available from AHRIdirectory.org. Heating Capacities and Efficiencies 460V Models UNIT 48VG-- A 36060 42060 36090 42090 48090 60090 48115 60115 48130 60130 HEATING INPUT (Btuh) OUTPUT CAPACITY (Btuh) TEMPERATURE RISE RANGE F (C) AFUE (%) 60,000 47,000 47,000 25--55 (13.9--30.6) 78.5 78.5 90,000 73,000 35--65 (19.4--36.1) 80.4 115,000 93,000 30--60 (16.7--33.3) 80.3 130,000 103,000 35--65 (19.4--36.1) 78.9 LEGEND AFUE—Annual Fuel Utilization Efficiency NOTE: Before purchasing this appliance, read important energy cost and efficiency information available from AHRIdirectory.org. 4 A--Weighted Sound Power Level (dBA) Model 48VG-A Sound Ratings (dBA) 24 30 36 42 48 60 73 77 73 73 72 75 TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment) 125 250 500 1000 2000 4000 8000 60.0 57.5 62.5 60.5 60.0 69.0 62.5 67.0 65.5 63.5 63.5 67.0 68.5 73.5 67.5 68.0 66.0 69.0 68.5 72.0 68.0 68.0 67.0 68.0 64.0 67.0 65.5 66.0 63.5 65.0 60.0 61.0 60.0 60.5 58.5 61.5 53.0 52.5 52.5 53.0 49.5 54.0 NOTE: Tested in accordance with AHRI Standard 270 (not listed in AHRI). UNIT SIZE NOMINAL CAPACITY (ton) SHIPPING WEIGHT** lb. SHIPPING WEIGHT** (kg) COMPRESSORS Quantity REFRIGERANT (R --- 410A) Quantity lb. Quantity (kg) REFRIGERANT METERING DEVICE OUTDOOR COIL Rows...Fins/in. Face Area (sq ft) OUTDOOR FAN Nominal CFM Diameter in. Diameter (mm) Motor Hp (Rpm) INDOOR COIL Rows...Fins/in. Face Area (sq ft) INDOOR BLOWER Nominal Low Stage Cooling Airflow (Cfm) Nominal High Stage Cooling Airflow (Cfm) Size in. Size (mm.) Motor HP (RPM) FURNACE SECTION* Burner Orifice No. (Qty...Drill Size) Natural Gas (Factory Installed) Propane Gas HIGH--PRESSURE SWITCH (psig) Cut--out Reset (Auto) LOSS--OF--CHARGE / LOW--PRESSURE SWITCH (psig) cut--out Reset (auto) DUCT RETURN--- AIR FILTERS†} Throwaway Size in. (mm) 24040 2 352 160 24060 2 352 160 30040 2 ---1/2 359 163 6.4 2.9 6.4 2.9 8.3 3.8 30060 36060 2 ---1/2 3 359 455 163 206 2 ---Stage Scroll 1 8.3 3.8 36090 3 455 206 42060 3 ---1/2 455 206 42090 3 ---1/2 455 206 8.1 3.7 8.1 3.7 8.7 3.9 8.7 3.9 TXV 1..21 13.6 1...21 13.6 2...21 13.6 2...21 13.6 2...21 13.6 2...21 13.6 2...21 13.6 2...21 13.6 2500 24 609.6 1/10 (810) 2500 24 609.6 1/10 (810) 2700 24 609.6 1/5 (810) 2700 24 609.6 1/5 (810) 3000 26 600.4 1/5 (810) 3000 26 600.4 1/5 (810) 3000 26 660.4 1/5 (810 3000 26 660.4 1/5 (810) 3...17 3.7 3...17 3.7 3...17 3.7 3...17 3.7 3...17 4.7 3...17 4.7 3...17 4.7 3...17 4.7 600 800 10x10 254x254 1/2 (1050) 600 800 10x10 254x254 1/2 (1050) 750 1000 10x10 254x254 1/2 (1050) 750 1000 10x10 254x254 1/2 (1050) 900 1200 11x10 279.4x254 3/4 (1000) 900 1200 11x10 279.4x254 3/4 (1000) 1050 1400 11x10 279.4x254 3/4 (1075) 1050 1400 11x10 279.4x254 3/4 (1075) 2...44 2...55 20x20x1 508x508x25 3...44 3...55 2...44 2...55 20x24x1 508x610x25 208/230 VAC Models 3...44 3...44 3...55 3...55 460 VAC Models 2…38 2…53 650 +/-- 15 420 +/-- 25 50 +/-- 7 95 +/-- 7 3…38 3…53 208/230 VAC Models 3...44 3...55 460 VAC Models 2…38 2…53 3...38 3...53 24x30x1 610x762x25 *Based on altitude of 0 to 2000 ft (0 ---610 m). { Required filter sizes shown are based on the larger of the AHRI (Air Conditioning Heating and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type. Air filter pressure drop for non ---standard filters must not exceed 0.08 IN. W.C. } If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity. 5 48VG -- A PHYSICAL DATA PHYSICAL DATA (CONT) 48VG -- A UNIT SIZE NOMINAL CAPACITY (ton) SHIPPING WEIGHT lb SHIPPING WEIGHT kg COMPRESSORS Quantity REFRIGERANT (R --- 410A) Quantity lb Quantity (kg.) REFRIGERANT METERING DEVICE OUTDOOR COIL Rows...Fins/in. Face Area (sq ft) OUTDOOR FAN Nominal Cfm Diameter in. Diameter (mm) Motor Hp (Rpm) INDOOR COIL Rows...Fins/in. Face Area (sq ft) INDOOR BLOWER Nominal Low Stage Cooling Airflow (Cfm) Nominal High Stage Cooling Airflow (Cfm) Size in. Size (mm) Motor HP (RPM) FURNACE SECTION* Burner Orifice No. (Qty...Drill Size) Natural Gas (Factory Installed) Propane Gas 48090 4 500 227 48115 4 500 227 10.8 4.9 10.8 4.9 48130 60090 4 5 500 520 227 236 2 ---Stage Scroll 1 10.8 4.9 60115 5 520 236 60130 5 520 236 12.1 5.5 12.1 5.5 12.1 5.5 TXV 2...21 19.4 2...21 19.4 2...21 19.4 2...21 21.4 2...21 21.4 2...21 21.4 3300 26 660.4 1/5 (810) 3300 26 660.4 1/5 (810) 3300 26 660.4 1/5 (810) 3600 26 660.4 1/5 (810) 3600 26 660.4 1/5 (810) 3600 26 660.4 1/5 (810) 3...17 5.7 3...17 5.7 3...17 5.7 3...17 5.7 3...17 5.7 3...17 5.7 1200 1600 11x10 279.4x254 1.0 (1075) 1200 1600 11x10 279.4x254 1.0 (1075) 1200 1600 11x10 279.4x254 1.0 (1075) 1200 1750 11x10 279.4x254 1.0 (1075) 1200 1750 11x10 279.4x254 1.0 (1075) 1200 1750 11x10 279.4x254 1.0 (1075) 3...38 3...53 3...33 3...51 3...31 3...49 3...38 3...53 3...33 3...51 3...31 3...49 HIGH--PRESSURE SWITCH 650 +/-- 15 (psig) Cut--out Reset (Auto) 420 +/-- 25 LOSS--OF--CHARGE / LOW--PRESSURE 50 +/--7 SWITCH (psig) cut--out Reset (auto) 95 +/-- 7 DUCT RETURN--AIR FILTERS Throwaway†} in. 24x36x1 (mm) 610x914x25 *Based on altitude of 0 to 2000 ft (0 ---610 m). { Required filter sizes shown are based on the larger of the AHRI (Air Conditioning Heating and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type. Air filter pressure drop for non ---standard filters must not exceed 0.08 IN. W.C. } If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity. 6 OPTIONS AND ACCESSORIES DESCRIPTION FACTORY INSTALLED OPTION FIELD INSTALLED ACCESSORY Coil Options Base unit with tin plated indoor coil hairpins Compressor Start Kit Compressor Start Kit assists compressor start--- up by providing additional starting torque on sing phase units only. X Corporate Thermostats Thermostats provide control for the system heating and cooling functions. X Crankcase Heater Crankcase Heater provides anti--- floodback protection for low--- load cooling applications. X* Vertical Economizer with Jade Honeywell W7220 Controller, Honeywell communicating actuator, and dry bulb sensor. (Contact MicroMetl Customer Service at 1--- 800--- 662--- 4822 to order.) X Horizontal Economizer with Jade Honeywell W7220 Controller, Honeywell communicating actuator, and dry bulb sensor. (Contact MicroMetl Customer Service at 1--- 800--- 662--- 4822 to order.) X Economizer X Filter Rack Filter Rack features easy installation, serviceability, and high--- filtering performance for vertical applications. Includes 1--- in. filter. Flat Roof Curbs Flat Roof Curbs in both 11--- in (279 mm) and 14--- in. (356 mm) sizes are available for roof mounted applications. X Flue Discharge Deflector Directs flue gas exhaust 90 degrees upward from current discharge. X Heat Exchanger Stainless Steel Heat Exchanger High Altitude Propane Conversion Kit High Altitude Propane Conversion Kit is for use at 2001 to 6000 ft. (611--- 1829 m) above sea level. Kit consists of propane gas orifices that compensate for gas heat operation at high altitude. X Low Ambient Kit Low Ambient Kit (Motormaster II Control) allows the use of mechanical cooling down to outdoor temperatures as low as 0°F (--- 18° C) when properly installed. X Manual Outside Air Damper Manual Outside Air Damper includes hood and filter rack with adjustable damper blade for up to 25% outdoor air. X Natural to Propane Gas Conversion Kit Natural to Propane Gas Conversion Kit allows for conversion from natural gas to propane gas (0--- 2000 ft) (0--- 610 m) X Propane to Natural Gas Conversion Kit Propane to Natural Gas Conversion Kit allows for conversion from propane to natural gas for altitudes of 0--- 2000 ft (0--- 610 m) X Square--- to--- Round Duct Transition Kit Square--- to--- Round Duct Transition Kit enable 24--- 48 size units to be fitted to 14 in. (356 mm) round ductwork. X Time Guard II Automatically prevents the compressor from restarting for at least 4 minutes and 45 seconds after shutdown of the compressor. Not required when a corporate programmable thermostat is applied or with a RTU--- MP control. X *Refer to Price Page for application detail. 7 X X X 48VG -- A ITEM 87.9 39.9 77.6 35.2 84.1 38.2 94.4 42.8 89.7 40.7 79.0 35.8 85.8 38.9 96.5 43.8 48VG -- A UNIT DIMENSIONS - 48VG--A24--30 A13012 8 97.5 97.5 107.0 110.9 44. 3 44.2 48.5 50.3 86.4 86.5 95.3 98.6 140.2 139.8 153.6 160.2 48VG -- A 56.2 56.3 61.8 64.5 202.8 202.8 223.2 232.3 39.2 123.9 39.2 124.2 43.2 136.1 44.7 142.2 447 447 492 512 63.6 63.4 69.7 72.7 UNIT DIMENSIONS - 48VG--A36--60 A13013 9 ACCESSORY DIMENSIONS Dashed lines show cross support location for large basepan units. B G HVAC unit basepan HVAC unit base rails C Sealing Gasket Roofcurb A Anchor screw H F Wood nailer* Flashing field supplied Roofcurb* Insulation (field supplied) Roofing material field supplied 48VG -- A E D Cant strip field supplied SMALL/COMMON CURB A09413 *Provided with roofcurb A09090 ROOF CURB DETAIL B C G SUPPLY AIR SMALL BASE UNIT RETURN AIR LARGE BASE UNIT H F A E D UNIT PLACEMENT ON COMMON CURB SMALL OR LARGE BASE UNIT A09415 LARGE CURB A09094 A09414 UNIT SIZE CATALOG NUMBER Small or Large CPRFCURB010A00 Large CPRFCURB011A00 CPRFCURB012A00 CPRFCURB013A00 A IN. (mm) 11 (279) 14 (356) 11 (279) 14 (356) B (small / common base) IN. (mm)* B (large base) IN. (mm)* C IN. (mm) D IN. (mm) E IN. (mm) F IN. (mm) 32.4 (822) 10 (254) 14 (356) 16 (406) 47.8 (1214) H IN. (mm) 30.6 (778) 2.7 (69) 43.9 (1116) 14 (356) G IN. (mm) 46.1 (1170) 42.2 (1072) * Part Numbers CPRCURB010A00 and CPRCURB011A00 can be used on both small and large basepan units. The cross supports must be located based on whether the unit is a small basepan or a large basepan. NOTES: 1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied, as required, to unit being installed. 3. Roof curb is made of 16--gauge steel. 4. Attach ductwork to curb (flanges of duct rest on curb). 5. Insulated panels: 1--in. (25.4 mm) thick fiberglass 1 lb. density. 10 1. Determine cooling and heating requirements at design conditions: 4. Determine fan speed and power requirements at design conditions. Given: Required Cooling Capacity (TC) . . . . . . . . . . 34,000 Btuh Sensible Heat Capacity (SHC) . . . . . . . . . . . . 25,000 Btuh Required Heating Capacity . . . . . . . . . . . . . . . 60,000 Btuh Condenser Entering Air Temperature . . . . . . . 95F (35C) Indoor--Air Temperature . 80F (26C)edb 67F (19C)ewb Evaporator Air Quantity . . . . . . . . . . . . . . . . . . 1200 CFM External Static Pressure . . . . . . . . . . . . . . . . 0.100 IN. W.C. Electrical Characteristics . . . . . . . . . . . . . . . . . . . 208--1--60 Before entering the air delivery tables, calculate the total static pressure required. From the given example, the Wet Coil Pressure Drop Table, and the Filter Pressure Drop Table: External Static Pressure 0.100 IN. W.C Filter 0.07 IN. W.C Wet Coil Pressure Drop 0.180 IN. W.C Total Static Pressure 0.287 IN. W.C Enter the table for Dry Coil Air Delivery—Horizontal and Downflow Discharge. At .287 IN. W.C. ESP, the closest speed to 1200 CFM is Med--Low (pink wire), which delivers 1262 CFM at .3 in ESP. 2. Select unit based on required cooling capacity. Enter Net Cooling Capacities table at condenser entering temperature of 95F (35C). Unit 036 at 1200 cfm and 67F (19C) ewb (entering wet bulb) will provide a total capacity of 34,200 Btuh and a SHC of 27,400 Btuh. Calculate SHC correction, if required, using Note 4 under Cooling Capacities tables. 5. Select unit that corresponds to power source available. The Electrical Data Table shows that the unit is designed to operate at 208--1--60. 3. Select heating capacity of unit to provide design condition requirement. In the Heating Capacities and Efficiencies table, note that the unit 036090 (208/230 VAC) will provide 74,000 Btuh with an input of 90,000 Btuh in high stage and will provide 47,000 Btuh of heating in low stage. 11 48VG -- A SELECTION PROCEDURE (WITH EXAMPLE) 12 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) EWB 19.29 15.50 16.16 12.71 19.25 20.64 22.59 14.57 18.96 19.29 18.61 18.65 19.26 18.60 18.60 19.26 11.42 21.87 12.08 14.13 19.95 22.29 13.61 18.58 15.15 16.78 18.21 20.34 17.82 17.82 1.03 1.06 1.09 1.09 1.09 1.02 1.05 1.08 1.08 1.08 1.01 1.04 1.07 1.07 1.08 75 (23.9) Capacity Total MBtuh Syst Total Sens KW See Legend and Notes on Page 24. 675 600 525 CFM EVAPORATOR AIR 024 Low Cool PERFORMANCE DATA 20.61 18.83 17.56 17.75 17.73 20.35 18.58 17.31 17.17 17.14 20.00 18.24 16.98 16.66 16.44 11.39 14.58 13.97 17.75 17.73 10.81 13.66 13.11 17.17 17.14 10.22 12.71 12.24 15.16 16.44 1.20 1.23 1.25 1.25 1.25 1.19 1.22 1.24 1.24 1.24 1.18 1.21 1.23 1.24 1.24 85 (29.4) Capacity Total MBtuh Syst Total Sens KW 18.64 17.03 15.88 16.22 16.20 18.43 16.82 15.67 15.71 15.68 18.14 16.54 15.39 15.11 15.06 10.12 13.03 12.47 16.22 16.20 9.59 12.20 11.69 15.71 15.68 9.05 11.34 10.90 15.05 15.06 1.39 1.41 1.43 1.42 1.42 1.37 1.40 1.42 1.42 1.42 1.36 1.39 1.41 1.41 1.41 16.69 15.24 14.21 14.68 14.66 16.52 15.06 14.03 14.23 14.21 16.28 14.83 13.80 13.69 13.67 8.88 11.53 11.01 14.68 14.66 8.40 10.77 10.31 14.23 14.21 7.92 10.00 9.59 13.69 13.67 1.58 1.61 1.63 1.62 1.62 1.57 1.60 1.61 1.61 1.61 1.56 1.58 1.60 1.60 1.60 14.74 13.45 12.53 13.13 13.11 14.61 13.31 12.39 12.75 12.73 14.42 13.13 12.20 12.28 12.27 7.68 10.06 9.59 13.13 13.11 7.26 9.39 8.97 12.75 12.73 6.82 8.69 8.32 12.28 12.27 1.80 1.82 1.84 1.83 1.83 1.79 1.81 1.83 1.82 1.82 1.78 1.80 1.82 1.81 1.81 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) 115 (46.1) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh Syst Syst Syst Total Sens Total Sens Total Sens KW KW KW 48VG -- A 12.83 11.70 10.89 11.59 11.57 12.73 11.59 10.77 11.27 11.25 12.59 11.44 10.62 10.88 10.86 6.55 8.65 8.21 11.59 11.57 6.17 8.05 7.67 11.27 11.25 5.78 7.44 7.10 10.88 10.86 2.03 2.05 2.07 2.06 2.06 2.02 2.04 2.06 2.05 2.05 2.01 2.03 2.05 2.04 2.04 125 (51.7) Capacity Total MBtuh Syst Total Sens KW 13 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) EWB 25.86 19.95 20.76 16.37 25.97 27.81 30.37 18.77 25.56 25.86 23.30 25.14 25.82 24.94 24.94 25.82 14.76 29.38 15.58 18.20 26.85 29.94 17.56 25.02 19.50 21.58 24.55 27.40 23.89 23.89 1.64 1.62 1.60 1.60 1.60 1.62 1.60 1.58 1.58 1.57 1.60 1.57 1.56 1.55 1.55 75 (23.9) Capacity Total MBtuh Sys Total Sens KW See Legend and Notes on Page 24. 900 800 700 CFM EVAPORATOR AIR 024 High Cool PERFORMANCE DATA (CONT) 27.89 25.54 23.86 23.98 23.95 27.52 25.19 23.51 23.20 23.16 27.04 24.72 23.05 22.62 22.22 15.53 19.83 19.03 23.98 23.95 14.76 18.60 17.89 23.20 23.16 13.97 17.34 16.72 20.64 22.22 1.80 1.77 1.75 1.76 1.76 1.78 1.75 1.73 1.73 1.73 1.75 1.73 1.71 1.71 1.70 85 (29.4) Capacity Total MBtuh Sys Total Sens KW 25.42 23.30 21.77 22.11 22.08 25.12 23.00 21.48 21.41 21.38 24.71 22.61 21.08 20.72 20.54 14.69 18.89 18.11 22.11 22.08 13.94 17.70 17.00 21.41 21.38 13.17 16.48 15.86 19.69 20.54 1.97 1.94 1.92 1.92 1.92 1.95 1.92 1.90 1.90 1.90 1.92 1.89 1.87 1.87 1.87 22.99 21.07 19.70 20.23 20.20 22.74 20.83 19.46 19.62 19.59 22.42 20.50 19.13 18.89 18.86 13.85 17.95 17.18 20.23 20.20 13.12 16.80 16.11 19.62 19.59 12.38 15.61 15.01 18.89 18.86 20.59 18.88 17.66 18.35 18.33 20.40 18.68 17.46 17.83 17.81 20.14 18.42 17.19 17.20 17.17 48VG -- A 2.15 2.12 2.10 2.11 2.11 2.13 2.10 2.08 2.08 2.08 2.10 2.07 2.06 2.05 2.05 13.01 17.01 16.25 18.35 18.33 12.31 15.89 15.22 17.83 17.81 11.59 14.75 14.15 17.20 17.17 2.35 2.32 2.30 2.31 2.31 2.33 2.30 2.28 2.28 2.28 2.30 2.27 2.26 2.26 2.26 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) 115 (46.1) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh Sys Sys Sys Total Sens Total Sens Total Sens KW KW KW 18.26 16.76 15.68 16.50 16.48 18.12 16.60 15.51 16.06 16.04 17.91 16.39 15.30 15.52 15.50 12.18 16.07 15.32 16.50 16.48 11.50 15.00 14.34 16.06 16.04 10.81 13.89 13.30 15.52 15.50 2.56 2.54 2.52 2.53 2.53 2.54 2.52 2.50 2.51 2.51 2.52 2.49 2.48 2.48 2.48 125 (51.7) Capacity Total MBtuh Sys Total Sens KW 14 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) EWB 1.42 17.36 14.14 23.33 22.18 17.87 18.62 14.94 24.14 24.18 18.95 19.78 15.67 25.19 27.74 23.33 23.49 23.87 25.72 28.29 24.14 24.18 24.24 26.09 28.69 1.45 16.69 23.36 1.47 1.46 1.47 1.40 1.43 1.45 1.45 1.45 1.38 1.41 1.43 1.43 20.51 22.91 1.43 22.30 Sens Total Syst KW 22.30 Total 75 (23.9) Capacity MBtuh See Legend and Notes on Page 24. 840 750 655 CFM EVAPORATOR AIR 030 Low Cool PERFORMANCE DATA (CONT) 25.62 23.31 21.66 21.82 21.79 25.30 23.00 21.36 21.12 21.08 24.84 22.57 20.94 20.54 20.19 Total 13.42 17.06 16.32 21.82 21.79 12.78 16.04 15.38 21.12 21.08 12.08 14.93 14.35 17.72 20.19 Sens 85 (29.4) Capacity MBtuh 1.48 1.50 1.52 1.52 1.52 1.46 1.48 1.50 1.50 1.50 1.44 1.46 1.48 1.48 1.49 22.63 20.60 19.15 19.50 19.48 22.37 20.35 18.90 18.90 18.87 22.00 19.99 18.55 18.23 18.10 11.27 14.43 13.79 19.50 19.48 10.72 13.55 12.98 18.90 18.87 10.11 12.60 12.09 15.01 18.10 1.53 1.55 1.56 1.56 1.56 1.51 1.53 1.55 1.54 1.54 1.49 1.51 1.53 1.53 1.53 19.71 17.95 16.68 17.21 17.18 19.51 17.75 16.48 16.70 16.68 19.22 17.47 16.21 16.05 16.02 9.21 11.90 11.35 17.21 17.18 8.75 11.16 10.67 16.70 16.68 8.24 10.36 9.92 16.05 16.02 1.57 1.59 1.60 1.59 1.59 1.55 1.57 1.58 1.58 1.58 1.54 1.55 1.56 1.57 1.57 16.86 15.36 14.28 14.94 14.92 16.72 15.21 14.12 14.53 14.51 16.51 15.00 13.91 13.99 13.97 7.26 9.47 9.02 14.94 14.92 6.88 8.87 8.46 14.53 14.51 6.47 8.21 7.86 13.99 13.97 1.60 1.61 1.62 1.61 1.61 1.58 1.59 1.61 1.60 1.60 1.57 1.58 1.59 1.59 1.59 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) 115 (46.1) Total Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh Syst Syst Syst Syst KW KW KW Total Sens Total Sens Total Sens KW 48VG -- A 14.12 12.87 11.96 12.72 12.71 14.03 12.76 11.84 12.39 12.38 13.88 12.60 11.68 11.97 11.95 5.44 7.16 6.80 12.72 12.71 5.14 6.70 6.38 12.39 12.38 4.82 6.19 5.91 11.97 11.95 1.61 1.62 1.63 1.62 1.62 1.59 1.60 1.61 1.61 1.61 1.58 1.59 1.60 1.60 1.60 125 (51.7) Capacity Total MBtuh Syst KW Total Sens 15 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) EWB 33.13 24.42 25.44 20.21 33.47 35.96 39.41 23.02 32.92 33.13 28.44 32.39 33.07 31.92 31.92 33.07 18.28 38.04 19.27 22.38 34.66 38.82 21.56 32.20 23.93 26.39 31.60 35.39 30.54 30.54 2.12 2.08 2.05 2.05 2.05 2.08 2.04 2.02 2.01 2.01 2.05 2.01 1.98 1.98 1.97 75 (23.9) Capacity Total MBtuh Sys Total Sens KW See Legend and Notes on Page 24. 1125 1000 875 CFM EVAPORATOR AIR 030 High Cool PERFORMANCE DATA (CONT) 35.75 32.64 30.41 30.38 30.34 35.26 32.18 29.95 29.52 29.32 34.61 31.55 29.34 28.82 28.11 18.94 24.00 23.02 30.38 30.34 18.03 22.57 21.68 26.89 29.32 17.09 21.07 20.29 24.96 28.11 2.29 2.25 2.23 2.23 2.23 2.26 2.22 2.19 2.19 2.19 2.22 2.19 2.16 2.15 2.15 85 (29.4) Capacity Total MBtuh Sys Total Sens KW 32.16 29.39 27.40 27.67 27.63 31.76 29.00 27.01 26.78 26.74 31.23 28.49 26.51 26.06 25.68 17.68 22.58 21.64 27.67 27.63 16.81 21.20 20.35 26.78 26.74 15.91 19.77 19.02 23.52 25.68 2.49 2.45 2.42 2.43 2.43 2.46 2.42 2.39 2.39 2.39 2.42 2.38 2.36 2.35 2.35 28.60 26.17 24.41 24.94 24.91 28.30 25.86 24.10 24.19 24.16 27.87 25.45 23.69 23.34 23.24 16.42 21.16 20.24 24.94 24.91 15.59 19.84 19.02 24.19 24.16 14.73 18.47 17.75 23.16 23.24 25.11 22.98 21.46 22.21 22.18 24.87 22.74 21.21 21.58 21.55 24.55 22.42 20.88 20.81 20.78 48VG -- A 2.71 2.67 2.64 2.65 2.65 2.67 2.64 2.61 2.61 2.61 2.64 2.60 2.58 2.57 2.57 15.17 19.72 18.84 22.21 22.18 14.37 18.46 17.67 21.58 21.55 13.55 17.16 16.46 20.81 20.78 2.95 2.91 2.89 2.90 2.90 2.92 2.88 2.86 2.87 2.87 2.89 2.85 2.83 2.83 2.83 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) 115 (46.1) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh Sys Sys Sys Total Sens Total Sens Total Sens KW KW KW 21.72 19.90 18.57 19.51 19.49 21.55 19.70 18.37 18.99 18.97 21.31 19.45 18.12 18.36 18.33 13.93 18.28 17.42 19.51 19.49 13.17 17.10 16.33 18.99 18.97 12.39 15.86 15.18 18.36 18.33 3.22 3.19 3.17 3.19 3.19 3.19 3.16 3.14 3.15 3.15 3.16 3.13 3.11 3.12 3.12 125 (51.7) Capacity Total MBtuh Sys Total Sens KW 16 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) EWB 28.02 22.71 23.73 18.66 27.84 29.94 32.87 21.37 27.41 28.02 27.07 27.07 27.98 27.03 27.03 27.98 16.77 31.81 17.75 20.73 28.92 32.43 19.92 26.84 22.28 24.60 26.33 29.51 25.86 25.86 1.51 1.54 1.56 1.56 1.56 1.50 1.53 1.55 1.55 1.55 1.48 1.51 1.53 1.54 1.54 75 (23.9) Capacity Total MBtuh Syst Total Sens KW See Legend and Notes on Page 24. 1010 900 785 CFM EVAPORATOR AIR 036 Low Cool PERFORMANCE DATA (CONT) 29.50 26.88 24.99 25.41 25.37 29.14 26.52 24.64 24.59 24.55 28.62 26.02 24.16 23.73 23.52 16.57 21.21 20.28 25.41 25.37 15.74 19.89 19.06 24.59 24.55 14.85 18.48 17.75 22.02 23.52 1.62 1.65 1.67 1.66 1.66 1.61 1.63 1.65 1.65 1.65 1.59 1.62 1.64 1.64 1.64 85 (29.4) Capacity Total MBtuh Syst Total Sens KW 26.21 23.89 22.22 22.83 22.80 25.92 23.59 21.93 22.12 22.09 25.50 23.18 21.53 21.23 21.19 14.55 18.76 17.92 22.83 22.80 13.80 17.58 16.82 22.12 22.09 13.00 16.30 15.63 21.23 21.19 1.73 1.75 1.77 1.76 1.76 1.71 1.74 1.75 1.75 1.75 1.70 1.72 1.74 1.74 1.74 22.99 20.96 19.49 20.28 20.25 22.76 20.72 19.25 19.68 19.65 22.43 20.39 18.93 18.92 18.89 12.60 16.38 15.62 20.28 20.25 11.93 15.32 14.64 19.68 19.65 11.22 14.19 13.59 18.92 18.89 1.83 1.85 1.87 1.86 1.86 1.82 1.84 1.85 1.85 1.85 1.80 1.82 1.84 1.84 1.84 19.84 18.09 16.82 17.75 17.72 19.67 17.90 16.63 17.25 17.23 19.42 17.65 16.37 16.62 16.59 10.73 14.07 13.38 17.75 17.72 10.14 13.15 12.53 17.25 17.23 9.51 12.15 11.61 16.62 16.59 1.93 1.95 1.96 1.95 1.95 1.92 1.94 1.95 1.94 1.94 1.90 1.92 1.94 1.93 1.93 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) 115 (46.1) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh Syst Syst Syst Total Sens Total Sens Total Sens KW KW KW 48VG -- A 16.79 15.32 14.28 15.25 15.24 16.67 15.16 14.08 14.86 14.84 16.49 14.97 13.88 14.35 14.33 8.94 11.82 14.28 15.25 15.24 8.43 11.05 10.51 14.86 14.84 7.89 10.19 9.71 14.35 14.33 2.02 2.04 2.05 2.04 2.04 2.01 2.03 2.04 2.03 2.03 2.00 2.02 2.03 2.02 2.02 125 (51.7) Capacity Total MBtuh Syst Total Sens KW 17 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) EWB 38.82 30.63 31.90 25.24 39.08 41.92 45.86 28.86 38.44 38.82 35.72 37.84 38.77 37.44 37.44 38.77 22.80 44.31 24.05 28.03 40.43 45.20 27.02 37.62 30.00 33.14 36.94 41.27 35.86 35.86 2.46 2.41 2.38 2.37 2.37 2.43 2.38 2.34 2.34 2.33 2.39 2.34 2.31 2.30 2.29 75 (23.9) Capacity Total MBtuh Sys Total Sens KW See Legend and Notes on Page 24. 1350 1200 1050 CFM EVAPORATOR AIR 036 High Cool PERFORMANCE DATA (CONT) 42.55 38.92 36.30 36.40 36.36 41.98 38.37 35.75 35.28 35.15 41.22 37.63 35.04 34.42 33.72 23.81 30.29 29.05 36.40 36.36 22.65 28.45 27.35 35.09 35.15 21.45 26.55 25.57 31.53 33.72 2.68 2.63 2.59 2.59 2.59 2.64 2.59 2.56 2.56 2.55 2.61 2.56 2.53 2.52 2.51 85 (29.4) Capacity Total MBtuh Sys Total Sens KW 39.20 35.87 33.49 33.92 33.88 38.71 35.40 33.01 32.85 32.81 38.07 34.79 32.41 31.86 31.52 22.37 28.67 27.48 33.92 33.88 21.25 26.90 25.83 32.85 32.81 20.10 25.07 24.12 29.88 31.52 2.92 2.86 2.83 2.84 2.84 2.88 2.83 2.80 2.80 2.80 2.85 2.80 2.77 2.76 2.76 35.78 32.77 30.61 31.37 31.33 35.39 32.38 30.22 30.43 30.39 34.86 31.86 29.71 29.31 29.26 20.92 27.04 25.88 31.37 31.33 19.85 25.34 24.30 30.43 30.39 18.73 23.58 22.66 29.31 29.26 32.32 29.62 27.68 28.72 28.69 32.00 29.29 27.35 27.92 27.88 31.58 28.87 26.94 26.93 26.89 48VG -- A 3.18 3.13 3.10 3.11 3.11 3.15 3.10 3.07 3.07 3.07 3.11 3.07 3.03 3.03 3.03 19.48 25.40 24.26 28.72 28.69 18.44 23.77 22.75 27.92 27.88 17.37 22.07 21.18 26.93 26.89 3.48 3.43 3.40 3.42 3.42 3.45 3.40 3.37 3.38 3.38 3.41 3.37 3.34 3.34 3.34 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) 115 (46.1) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh Sys Sys Sys Total Sens Total Sens Total Sens KW KW KW 28.86 26.47 24.75 26.03 26.00 28.62 26.20 24.48 25.34 25.31 28.28 25.86 24.13 24.51 24.47 18.05 23.74 22.63 26.03 26.00 17.05 22.20 21.21 25.34 25.31 16.02 20.58 19.71 24.51 24.47 3.81 3.77 3.74 3.76 3.76 3.79 3.74 3.71 3.73 3.73 3.75 3.71 3.69 3.69 3.69 125 (51.7) Capacity Total MBtuh Sys Total Sens KW 18 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) EWB 33.62 26.93 28.15 22.25 33.55 36.17 39.84 25.34 33.02 33.62 32.36 32.52 33.57 32.40 32.40 33.57 20.01 38.48 21.17 24.60 34.88 39.26 23.63 32.30 26.44 29.10 31.67 35.63 30.96 30.96 1.92 1.95 1.98 1.98 1.98 1.89 1.93 1.95 1.95 1.95 1.87 1.90 1.92 1.93 1.93 75 (23.9) Capacity Total MBtuh Syst Total Sens KW See Legend and Notes on Page 24. 1180 1050 915 CFM EVAPORATOR AIR 042 Low Cool PERFORMANCE DATA (CONT) 36.39 33.07 30.68 31.04 31.00 35.92 32.61 30.24 30.01 29.96 35.25 31.98 29.63 29.07 28.67 19.94 25.40 24.28 31.04 31.00 18.95 23.83 22.82 30.01 29.96 17.89 22.15 21.25 26.30 28.67 1.96 1.99 2.02 2.01 2.01 1.93 1.97 1.99 1.99 2.00 1.91 1.94 1.97 1.97 1.98 85 (29.4) Capacity Total MBtuh Syst Total Sens KW 32.92 29.92 27.77 28.42 28.38 32.54 29.55 27.41 27.51 27.47 31.99 29.02 26.89 26.44 26.33 17.68 22.69 21.66 28.42 28.38 16.78 21.26 20.34 27.51 27.47 15.82 19.73 18.92 26.27 26.33 1.99 2.03 2.05 2.05 2.05 1.97 2.01 2.03 2.03 2.03 1.95 1.98 2.01 2.01 2.01 29.44 26.76 24.85 25.74 25.70 29.14 26.46 24.54 24.96 24.92 28.70 26.03 24.12 23.97 23.93 15.49 20.04 19.10 25.74 25.70 14.67 18.75 17.91 24.96 24.92 13.81 17.38 16.63 23.97 23.93 2.02 2.05 2.08 2.07 2.07 2.00 2.03 2.06 2.05 2.05 1.98 2.01 2.04 2.04 2.04 25.95 23.60 21.90 23.02 22.99 25.72 23.35 21.65 22.35 22.32 25.38 23.01 21.31 21.51 21.48 13.37 17.46 16.60 23.02 22.99 12.64 16.31 15.55 22.35 22.32 11.87 15.09 14.41 21.51 21.48 2.02 2.06 2.09 2.07 2.07 2.01 2.04 2.07 2.06 2.06 1.99 2.03 2.05 2.05 2.05 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) 115 (46.1) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh Syst Syst Syst Total Sens Total Sens Total Sens KW KW KW 48VG -- A 22.49 20.46 18.99 20.27 20.25 22.33 20.26 18.77 19.73 19.70 22.08 20.00 18.51 19.03 19.01 11.34 14.94 18.84 20.27 20.25 10.70 13.96 13.28 19.73 19.70 10.03 12.89 12.28 19.03 19.01 2.01 2.05 2.07 2.05 2.05 1.99 2.03 2.06 2.04 2.04 1.98 2.02 2.04 2.03 2.03 125 (51.7) Capacity Total MBtuh Syst Total Sens KW 19 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) EWB 47.60 35.58 37.00 29.22 47.97 51.31 55.92 33.56 47.25 47.60 41.52 46.52 47.54 45.98 45.98 47.54 26.44 54.17 27.86 32.58 49.63 55.17 31.46 46.30 34.83 38.57 45.47 50.58 44.10 44.10 2.84 2.80 2.77 2.77 2.77 2.79 2.76 2.73 2.73 2.72 2.75 2.71 2.69 2.68 2.67 75 (23.9) Capacity Total MBtuh Sys Total Sens KW See Legend and Notes on Page 24. 1575 1400 1225 CFM EVAPORATOR AIR 042 High Cool PERFORMANCE DATA (CONT) 51.07 46.89 43.88 43.95 43.89 50.45 46.29 43.28 42.71 42.52 49.61 45.48 42.48 41.76 40.87 27.57 35.17 33.79 43.95 43.89 26.26 33.07 31.84 42.37 42.52 24.90 30.90 29.82 36.75 40.87 3.12 3.08 3.05 3.05 3.05 3.08 3.04 3.01 3.01 3.01 3.04 3.00 2.97 2.96 2.95 85 (29.4) Capacity Total MBtuh Sys Total Sens KW 46.25 42.50 39.80 40.27 40.22 45.74 42.00 39.30 39.08 39.03 45.06 41.33 38.64 38.02 37.59 25.93 33.33 31.99 40.27 40.22 24.65 31.30 30.11 39.08 39.03 23.34 29.20 28.16 34.87 37.59 3.45 3.40 3.37 3.38 3.38 3.41 3.36 3.33 3.33 3.33 3.36 3.32 3.28 3.28 3.27 41.47 38.15 35.76 36.59 36.54 41.08 37.75 35.35 35.57 35.52 40.53 37.21 34.81 34.34 34.28 24.28 31.48 30.17 36.59 36.54 23.05 29.52 28.36 35.57 35.52 21.79 27.50 26.49 34.34 34.28 36.77 33.86 31.76 32.90 32.86 36.47 33.55 31.44 32.04 32.01 36.05 33.12 31.02 31.00 30.95 48VG -- A 3.81 3.76 3.72 3.74 3.74 3.76 3.72 3.68 3.69 3.69 3.72 3.67 3.64 3.63 3.63 22.64 29.62 28.34 32.90 32.86 21.45 27.75 26.61 32.04 32.01 20.23 25.80 24.81 31.00 30.95 4.20 4.15 4.12 4.14 4.13 4.16 4.11 4.07 4.08 4.08 4.11 4.06 4.03 4.03 4.03 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) 115 (46.1) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh Sys Sys Sys Total Sens Total Sens Total Sens KW KW KW 32.27 29.75 27.94 29.29 29.26 32.06 29.50 27.67 28.59 28.56 31.74 29.18 27.34 27.72 27.68 21.05 27.77 26.51 29.29 29.26 19.90 26.00 24.89 28.59 28.56 18.73 24.14 23.17 27.72 27.68 4.63 4.58 4.55 4.57 4.57 4.59 4.54 4.50 4.52 4.52 4.54 4.49 4.46 4.47 4.47 125 (51.7) Capacity Total MBtuh Sys Total Sens KW 20 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) EWB 37.81 30.32 31.70 25.09 37.81 40.80 44.98 28.96 37.37 37.81 36.82 36.82 37.76 36.76 36.76 37.76 22.88 43.68 24.17 28.19 39.58 44.51 27.06 36.62 30.24 33.38 35.89 40.36 35.18 35.18 2.15 2.19 2.21 2.21 2.21 2.12 2.15 2.18 2.18 2.18 2.08 2.11 2.14 2.14 2.15 75 (23.9) Capacity Total MBtuh Syst Total Sens KW See Legend and Notes on Page 24. 1310 1200 1050 CFM EVAPORATOR AIR 048 Low Cool PERFORMANCE DATA (CONT) 41.19 37.39 34.64 35.00 34.95 40.80 37.01 34.28 34.12 34.07 40.10 36.35 33.64 32.99 32.65 22.67 28.84 27.55 35.00 34.95 21.82 27.49 26.30 34.12 34.07 20.63 25.60 24.54 30.42 32.65 2.23 2.26 2.28 2.27 2.27 2.20 2.23 2.25 2.25 2.25 2.16 2.19 2.21 2.21 2.21 85 (29.4) Capacity Total MBtuh Syst Total Sens KW 37.37 33.93 31.45 32.15 32.10 37.07 33.63 31.15 31.37 31.32 36.50 33.07 30.61 30.13 30.08 20.30 26.03 24.84 32.15 32.10 19.52 24.79 23.69 31.37 31.32 18.44 23.05 22.07 30.13 30.08 2.28 2.31 2.32 2.32 2.32 2.26 2.28 2.30 2.29 2.29 2.22 2.24 2.26 2.26 2.26 33.55 30.46 28.23 29.24 29.20 33.30 30.21 27.99 28.58 28.53 32.85 29.78 27.55 27.49 27.45 18.00 23.28 22.18 29.24 29.20 17.29 22.14 21.13 28.58 28.53 16.30 20.56 19.66 27.49 27.45 2.31 2.33 2.35 2.34 2.34 2.29 2.31 2.32 2.32 2.32 2.26 2.28 2.29 2.29 2.29 29.70 26.96 24.98 26.27 26.23 29.52 26.77 24.79 25.71 25.68 29.17 26.42 24.45 24.80 24.76 15.77 20.59 19.58 26.27 26.23 15.13 19.57 18.64 25.71 25.68 14.23 18.13 17.30 24.80 24.76 2.32 2.33 2.34 2.34 2.34 2.29 2.31 2.32 2.32 2.32 2.26 2.28 2.29 2.29 2.29 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) 115 (46.1) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh Syst Syst Syst Total Sens Total Sens Total Sens KW KW KW 48VG -- A 25.85 23.47 21.76 23.26 23.23 25.74 23.32 21.59 22.80 22.77 25.49 23.06 21.33 22.04 22.01 13.64 17.97 21.62 23.26 23.23 13.06 17.07 16.21 22.80 22.77 12.25 15.78 15.03 22.04 22.01 2.28 2.29 2.31 2.30 2.30 2.26 2.28 2.29 2.28 2.28 2.24 2.25 2.26 2.25 2.26 125 (51.7) Capacity Total MBtuh Syst Total Sens KW 21 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) EWB 52.45 39.53 41.19 32.67 52.92 56.86 62.33 37.79 52.30 52.45 46.83 51.47 52.37 51.01 51.01 52.37 29.87 60.49 31.49 36.75 55.12 61.65 35.39 51.23 39.32 43.47 50.28 56.21 48.89 48.89 3.32 3.27 3.24 3.23 3.23 3.27 3.23 3.19 3.18 3.18 3.21 3.16 3.13 3.12 3.11 75 (23.9) Capacity Total MBtuh Sys Total Sens KW See Legend and Notes on Page 24. 1750 1600 1400 CFM EVAPORATOR AIR 048 High Cool PERFORMANCE DATA (CONT) 57.41 52.41 48.81 48.85 48.78 56.85 51.86 48.28 47.65 47.56 55.87 50.93 47.37 46.51 45.66 31.06 39.44 37.82 48.85 48.78 29.91 37.62 36.13 47.65 47.56 28.34 35.12 33.80 41.71 45.66 3.62 3.57 3.54 3.54 3.54 3.57 3.53 3.49 3.49 3.48 3.51 3.46 3.43 3.42 3.41 52.50 47.95 44.68 45.21 45.15 52.04 47.50 44.24 44.13 44.07 51.22 46.72 43.48 42.75 42.38 29.43 37.67 36.08 45.21 45.15 28.32 35.90 34.44 44.13 44.07 26.80 33.47 32.17 39.90 42.38 3.95 3.91 3.87 3.88 3.88 3.91 3.86 3.83 3.83 3.83 3.84 3.80 3.77 3.76 3.75 47.61 43.50 40.56 41.52 41.47 47.24 43.13 40.20 40.59 40.53 46.58 42.50 39.57 39.11 39.05 27.80 35.88 34.32 41.52 41.47 26.72 34.16 32.73 40.59 40.53 25.25 31.80 30.53 39.11 39.05 42.73 39.06 36.44 37.79 37.75 42.45 38.77 36.15 37.00 36.95 41.93 38.27 35.65 35.73 35.68 48VG -- A 4.32 4.28 4.24 4.26 4.25 4.28 4.23 4.20 4.20 4.20 4.22 4.17 4.14 4.13 4.13 26.16 34.07 32.53 37.79 37.75 25.11 32.40 30.99 37.00 36.95 23.68 30.11 28.86 35.73 35.68 4.72 4.68 4.65 4.66 4.66 4.68 4.64 4.60 4.62 4.62 4.62 4.58 4.54 4.55 4.55 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) Capacity Capacity Capacity Capacity Total Total Total Total MBtuh MBtuh MBtuh MBtuh Sys Sys Sys Sys Total Sens Total Sens Total Sens Total Sens KW KW KW KW 37.97 34.73 32.42 34.08 34.04 37.76 34.50 32.18 33.41 33.37 37.37 34.10 31.78 32.34 32.30 24.55 32.25 30.72 34.08 34.04 23.52 30.65 29.26 33.41 33.37 22.12 28.42 27.20 32.34 32.30 5.15 5.12 5.08 5.11 5.11 5.11 5.07 5.04 5.06 5.06 5.06 5.02 4.98 4.99 4.99 125 (51.7) Capacity Total MBtuh Sys Total Sens KW 22 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) EWB 46.03 36.92 38.62 30.56 45.92 49.57 54.62 34.73 45.25 46.03 44.18 44.59 45.96 44.36 44.36 45.96 27.58 52.94 29.08 33.87 47.96 53.90 32.51 44.37 36.25 40.01 43.53 48.88 42.50 42.50 75 (23.9) Capacity MBtuh Total Sens See Legend and Notes on Page 24. 1545 1370 1200 CFM EVAPORATOR AIR 060 Low Cool 2.69 2.71 2.73 2.73 2.73 2.62 2.65 2.67 2.67 2.67 2.56 2.59 2.61 2.61 2.61 Total Syst KW PERFORMANCE DATA (CONT) 52.62 47.78 44.29 44.84 44.78 52.00 47.18 43.69 43.36 43.29 51.15 46.38 42.92 42.15 41.54 29.14 37.08 35.42 44.84 44.78 27.69 34.77 33.28 43.36 43.29 26.23 32.46 31.12 38.49 41.54 85 (29.4) Capacity MBtuh Total Sens 2.71 2.73 2.75 2.75 2.75 2.65 2.68 2.69 2.69 2.69 2.60 2.62 2.63 2.64 2.64 50.31 45.71 42.38 43.41 43.35 49.80 45.19 41.88 42.05 41.98 49.07 44.50 41.20 40.55 40.36 27.69 35.51 33.88 43.41 43.35 26.28 33.26 31.80 42.05 41.98 24.86 31.00 29.70 40.24 40.36 2.71 2.72 2.73 2.73 2.73 2.65 2.67 2.68 2.68 2.68 2.60 2.62 2.63 2.63 2.63 47.64 43.29 40.14 41.65 41.59 47.23 42.87 39.71 40.42 40.36 46.63 42.28 39.14 38.94 38.87 26.20 33.88 32.27 41.65 41.59 24.83 31.70 30.26 40.42 40.36 23.45 29.49 28.21 38.94 38.87 2.66 2.67 2.68 2.67 2.67 2.61 2.62 2.63 2.63 2.63 2.57 2.58 2.59 2.59 2.59 44.54 40.48 37.53 39.51 39.46 44.23 40.13 37.17 38.42 38.36 43.75 39.65 36.69 37.09 37.03 24.66 32.18 30.58 39.51 39.46 23.32 30.07 28.64 38.42 38.36 21.98 27.93 26.66 37.09 37.03 2.56 2.57 2.57 2.57 2.57 2.52 2.53 2.53 2.53 2.53 2.48 2.49 2.49 2.49 2.49 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) 115 (46.1) Capacity Capacity Capacity Total Total Total Total MBtuh MBtuh MBtuh Syst Syst Syst Syst Total Sens Total Sens Total Sens KW KW KW KW 48VG -- A 40.98 37.28 34.57 36.97 36.92 40.79 36.99 34.23 36.03 35.98 40.44 36.60 33.85 34.87 34.82 23.08 30.36 34.35 36.97 36.92 21.77 28.37 26.95 36.03 35.98 20.47 26.30 25.05 34.87 34.82 2.39 2.40 2.41 2.40 2.40 2.36 2.37 2.37 2.37 2.37 2.33 2.33 2.34 2.34 2.34 125 (51.7) Capacity Total MBtuh Syst Total Sens KW 23 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) EWB 62.99 48.75 50.85 39.95 62.73 67.27 73.56 45.99 61.92 62.99 60.84 61.23 62.91 60.99 60.99 62.91 36.12 71.52 38.07 44.77 65.32 72.71 43.11 60.83 47.87 53.13 59.85 66.43 58.66 58.66 4.06 4.02 3.99 3.99 3.99 3.98 3.94 3.91 3.90 3.90 3.90 3.86 3.82 3.82 3.81 75 (23.9) Capacity Total MBtuh Sys Total Sens KW See Legend and Notes on Page 24. 2250 2000 1750 CFM EVAPORATOR AIR 060 High Cool PERFORMANCE DATA (CONT) 68.73 62.89 58.69 59.49 59.42 68.00 62.19 57.99 57.75 57.68 67.01 61.22 57.05 56.20 55.57 38.24 49.01 46.95 59.49 59.42 36.40 46.10 44.25 57.75 57.68 34.50 43.05 41.43 51.25 55.57 4.43 4.39 4.35 4.36 4.35 4.35 4.30 4.26 4.26 4.26 4.27 4.22 4.18 4.17 4.17 85 (29.4) Capacity Total MBtuh Sys Total Sens KW 63.76 58.40 54.54 55.83 55.76 63.17 57.80 53.95 54.29 54.22 62.34 57.00 53.16 52.51 52.33 36.50 47.12 45.08 55.83 55.76 34.70 44.27 42.45 54.29 54.22 32.84 41.30 39.70 52.25 52.33 4.86 4.80 4.76 4.77 4.77 4.78 4.72 4.67 4.68 4.68 4.69 4.63 4.58 4.58 4.58 58.61 53.75 50.24 51.99 51.93 58.16 53.27 49.76 50.64 50.58 57.48 52.61 49.10 48.99 48.92 34.70 45.15 43.14 51.99 51.93 32.94 42.39 40.60 50.64 50.58 31.12 39.48 37.91 48.99 48.92 53.29 48.94 45.80 47.94 47.89 52.95 48.55 45.40 46.80 46.74 52.44 48.03 44.88 45.37 45.32 48VG -- A 5.34 5.27 5.22 5.25 5.25 5.26 5.19 5.13 5.15 5.15 5.17 5.10 5.04 5.05 5.04 32.85 43.08 41.08 47.94 47.89 31.12 40.42 38.65 46.80 46.74 29.35 37.60 36.06 45.37 45.32 5.87 5.80 5.73 5.78 5.78 5.79 5.71 5.65 5.68 5.68 5.70 5.62 5.56 5.57 5.57 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) 115 (46.1) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh Sys Sys Sys Total Sens Total Sens Total Sens KW KW KW 47.96 44.15 41.35 43.79 43.74 47.73 43.81 41.00 42.83 42.79 47.35 43.40 40.58 41.63 41.58 31.01 40.88 38.84 43.79 43.74 29.31 38.42 36.66 42.83 42.79 27.57 35.70 34.17 41.63 41.58 6.46 6.38 6.30 6.37 6.37 6.37 6.29 6.22 6.27 6.27 6.29 6.20 6.13 6.16 6.16 125 (51.7) Capacity Total MBtuh Sys Total Sens KW 24 1.10 x cfm Sensible capacity (Btuh) = hewb --- hlwb Where: hewb = Enthalpy of air entering evaporator coil 4. The SHC is based on 805 F (26.6_C) edb temperature of air entering evaporator coil. Below 80_F (26.6_C) edb, subtract (corr factor x cfm) from SHC. Above 80_ F (26.6_C) edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 + BF) x (edb --- 80). 5. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 4.5 x cfm total capacity (Btuh) air leaving evaporator coil (hlwb) = Wet---bulb temperature corresponding to enthalpy = tedb --- tlwb tldb COOLING NOTES: 1. Ratings are net; they account for the effects of the evaporator ---fan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. The following formulas may be used: * At 75F (24C) entering dry bulb---Tennessee Valley Authority (TVA) rating conditions; all others at 80F (27C) dry bulb. LEGEND BF— Bypass Factor edb— Entering Dry ---Bulb Ewb— Entering Wet---Bulb kW — Total Unit Power Input SHC— Sensible Heat Capacity (1000 Btuh) TC — Total Capacity (1000 Btuh) (net) rh—Relative Humidity PERFORMANCE DATA (CONT) 48VG -- A PERFORMANCE DATA (CONT) GAS ADJUSTMENT Natural Gas Orifice Sizes and Manifold Pressure 208/230VAC Models 40000 60000 90000 115000 130000 Orifice No. (Qty) ALTITUDE OF INSTALLATION (FT. [m] ABOVE SEA LEVEL) U.S.A.* 2001 to 0 to 2000 3001 to 4000 4001 to 5000 5001 to 6000 3000* [0 to 610] [915 to 1219] [1220 to 1524] [1524 to 1829] [610 to 914] 44 (2) 45 (2)† 48 (2)† 48 (2)† 48 (2)† Manifold Press. High / Low (in. W.C.) Orifice No. (Qty) 3.2 /1.4 44 (3) 3.2 /1.4 45 (3)† 3.8 /1.6 48 (3)† 3.5 /1.5 48 (3)† 3.2 /1.4 48 (3)† Manifold Press. High / Low (in. W.C.) Orifice No. (Qty) 3.2 /1.4 38 (3) 3.2 /1.4 41 (3)† 3.8 /1.6 41 (3)† 3.5 /1.5 42 (3)† 3.2 /1.4 42 (3)† Manifold Press. High / Low (in. W.C.) Orifice No. (Qty) 3.6 /1.6 33 (3) 3.8 /1.6 36 (3)† 3.4 /1.5 36 (3)† 3.4 /1.5 36 (3)† 3.2 /1.4 38 (3)† Manifold Press. High / Low (in. W.C.) Orifice No. (Qty) Manifold Press. High / Low (in. W.C.) 3.8 /1.7 31 (3) 3.8 /1.7 3.8 /1.7 31 (3) 3.2 /1.4 3.6 /1.6 33 (3)† 3.7 /1.6 3.3 /1.4 33 (3)† 3.4 /1.4 3.6 /1.5 34 (3)† 3.3 /1.4 Natural Gas Orifice Sizes and Manifold Pressure 460V ALTITUDE OF INSTALLATION (FT. ABOVE SEA LEVEL) U.S.A.* 3001 to 4000 4001 to 5000 5001 to 6000 0 to 2000 2001 to 3000* (915 to 1219 (1220 to 1524 (1524 to 1829 (0--- 610 m) (611 to 914 m) m) m) m) Orifice No. (Qty) 38 (2) 41 (2)† 41 (2)† 42 (2)† 42 (2)† 60000 Manifold Press. (in. W.C.) 3.6 3.8 3.4 3.4 3.2 Orifice No. (Qty) 38 (3) 41 (3)† 41 (3)† 42 (3)† 42 (3)† 90000 Manifold Press. (in. W.C.) 3.6 3.8 3.4 3.4 3.2 Orifice No. (Qty) 33 (3) 36 (3)† 36 (3)† 36 (3)† 38 (3)† 115000 Manifold Press. (in. W.C.) 3.8 3.8 3.6 3.3 3.6 Orifice No. (Qty) 31 (3) 31 (3) 33 (3)† 33 (3)† 34 (3)† 130000 Manifold Press. (in. W.C.) 3.8 3.2 3.7 3.4 3.3 *In the U.S.A., the input rating for altitudes above 2000 ft (610m) must be reduced by 4% for each 1000 ft (305 m) above sea level. In Canada, the input rating for altitudes from 2001 to 4500 ft (611 to 1372 m) above sea level must be derated by 10% by an authorized gas conversion station or dealer. For Canadian Installations from 2000 to 4500 ft, use U.S.A. column 2001 to 3000 ft (610 to 914 m). † Orifices available through your distributor. Nameplate Input (Btu/hr) NOTE: Orifice sizes and manifold pressure settings are based on natural gas with a heating value of 1025 Btu/ft3 and a specific gravity of .6. Propane Gas Orifice Sizes and Manifold Pressure 208/230VAC Models Nameplate Input, High Stage (Btu/hr) 40000 60000 90000 115000 130000 ALTITUDE OF INSTALLATION (FT. ABOVE SEA LEVEL) U.S.A.*† Orifice No. (Qty) Manifold Press. High / Low (in. W.C.) Orifice No. (Qty) Manifold Press. High / Low (in. W.C.) Orifice No. (Qty) Manifold Press. High / Low (in. W.C.) Orifice No. (Qty) Manifold Press. High / Low (in. W.C.) Orifice No. (Qty) Manifold Press. High / Low (in. W.C.) 0 to 2000 [0 to 610] 2001 to 3000* [610 to 914] 3001 to 4000 [915 to 1219] 4001 to 5000 [1220 to 1524] 5001 to 6000 [1524 to 1829] 55 (2) 10.0/5.0 55 (3) 10.0/5.0 53 (3) 10.0/5.4 51 (3) 10.0/5.4 49 (3) 10.0/5.4 56 (2) 11.0/6.0 56 (3) 11.0/6.0 54 (3) 11.0/6.4 52 (3) 11.0/5.0 50 (3) 11.0/4.8 56 (2) 11.0/5.5 56 (3) 11.0/5.5 54 (3) 11.0/5.9 52 (3) 10.6/4.8 51 (3) 11.0/4.9 56 (2) 11.0/5.0 56 (3) 11.0/5.0 54 (3) 11.0/5.4 53 (3) 11.0/6.1 52 (3) 11.0/5.2 56 (2) 10.7/4.8 56 (3) 10.7/4.8 54 (3) 11.0/5.0 53 (3) 11.0/5.5 52 (3) 11.0/5.0 *In the U.S.A., the input rating for altitudes above 2000 ft (610m) must be reduced by 4% for each 1000 ft (305 m) above sea level. In Canada, the input rating for altitudes from 2001 to 4500 ft (611 to 1372 m) above sea level must be derated by 10% by an authorized gas conversion station or dealer. For Canadian Installations from 2000 to 4500 ft, use U.S.A. column 2001 to 3000 ft (610 to 914 m). † Use Kit No. CPLPCONV013B00 (0--- 2000 ft [0--- 610 m] above sea level. Use Kit No. CPLPCONV014B00 (2001--- 6000 ft [611--- 1829 m] above sea level. 25 48VG -- A Nameplate Input, High Stage (Btu/hr) PERFORMANCE DATA (CONT) Propane Gas Orifice Sizes and Manifold Pressure 460V ALTITUDE OF INSTALLATION (FT. ABOVE SEA LEVEL) U.S.A.* 0 to 2000 2001 to 3000* 3001 to 4000 4001 to 5000 5001 to 6000 (0--- 610 m) (611 to 914 m) (915 to 1219 m) (1220 to 1524 m) (1524 to 1829 m) Orifice No. (Qty) 53 (2) 54 (2) 54 (2) 54 (2) 54 (2) 60000 Manifold Press. (IN. W.C.) 10.0 11.0 11.0 11.0 11.0 Orifice No. (Qty) 53 (3) 54 (3) 54 (3) 54 (3) 54 (3) 90000 Manifold Press. (IN. W.C.) 10.0 11.0 11.0 11.0 11.0 Orifice No. (Qty) 51 (3) 52 (3) 52 (3) 53 (3) 53 (3) 115000 Manifold Press. (IN. W.C.) 10.0 11.0 10.6 11.0 11.0 Orifice No. (Qty) 49 (3) 50 (3) 51 (3) 52 (3) 52 (3) 130000 Manifold Press. (IN. W.C.) 10.0 11.0 11.0 11.0 11.0 *In the U.S.A., the input rating for altitudes above 2000 ft (610m) must be reduced by 4% for each 1000 ft (305 m) above sea level. In Canada, the input rating for altitudes from 2001 to 4500 ft (611 to 1372 m) above sea level must be derated by 10% by an authorized gas conversion station or dealer. For Canadian Installations from 2000 to 4500 ft (610 ---1372 m), use U.S.A. column 2001 to 3000 ft (611 to 914 m). †Use Kit No. CPLPCONV013B00 (0 ---2000 ft [0 ---610 m] above sea level). Use Kit No. CPLPCONV014B00 (2001 ---6000 ft [611 ---1829 m] above sea level). 48VG -- A Nameplate Input (Btu/hr) High Altitude Compensation: Natural Gas 208/230VAC Models Nameplate Input, High Stage (Btu/hr) Rated Heating Input (Btu/hr), Natural Gas at Installation Altitude Above Sea Level, U.S.A.* 0 to 2000 ft 0 to 610 m 2001 to 3000 ft* 610 to 914 m 3001 to 4000 ft 915 to 1219 m 4001 to 5000 ft 1220 to 1524 m 5001 to 6000 ft 1524 to 1829 m High Stage Low Stage High Stage Low Stage High Stage Low Stage High Stage Low Stage High Stage Low Stage 40000 40000 26000 36000 23400 34400 22300 32800 21300 31200 20300 60000 60000 39000 54000 35100 51600 33500 49200 32000 46800 30400 90000 90000 58500 81000 52700 77400 50300 73800 48000 70200 45600 115000 115000 75000 103500 67500 98900 64500 94300 61500 89700 58500 130000 130000 84500 117000 76100 111800 72700 106600 69300 101400 65900 High Altitude Compensation, Natural Gas 460V Rated Heating Input (Btu/hr), Natural Gas at Installation Altitude Above Sea Level, U.S.A.* 0 to 2000 ft 2001 to 3000 ft* 3001 to 4000 ft 4001 to 5000 ft 5001 to 6000 ft (0--- 610 m) (611 to 914 m) (915 to 1219 m) (1220 to 1524 m) (1524 to 1829 m) 60000 60000 54000 51600 49200 46800 90000 90000 81000 77400 73800 70200 115000 115000 103500 98900 94300 89700 130000 130000 117000 111800 106600 101400 *In the U.S.A., the input rating for altitudes above 2000 ft (610m) must be reduced by 4% for each 1000 ft (305 m) above Sea level. In Canada, the input rating for altitudes from 2001 to 4500 ft (611 to 1372 m) above sea level must be derated by 10% by an authorized gas conversion station or dealer. For Canadian Installations from 2000 to 4500 ft (610 ---1372 m), use U.S.A. column 2001 to 3000 ft (611 to 914 m). Nameplate Input (Btu/hr) High Altitude Compensation: Propane Gas 208/230VAC Models Nameplate Input, High Stage (Btu/hr) Rated Heating Input (Btu/hr), LP Gas at Installation Altitude Above Sea Level, U.S.A.* 0 to 2000 ft 0 to 610 m 2001 to 3000 ft* 610 to 914 m 3001 to 4000 ft 915 to 1219 m 4001 to 5000 ft 1220 to 1524 m 5001 to 6000 ft 1524 to 1829 m High Stage Low Stage High Stage Low Stage High Stage Low Stage High Stage Low Stage High Stage Low Stage 40000 38000 26000 31700 23400 31700 22300 31700 21300 31200 20300 60000 57000 39000 47500 35100 47500 33500 47500 32000 46800 30400 90000 79000 58500 68900 52700 68900 50300 68600 48000 68600 45600 115000 103000 75000 100400 67500 98900 64500 83000 61500 83000 58500 130000 116000 84500 115500 76100 111800 72700 101300 69300 100400 65900 *In the U.S.A., the input rating for altitudes above 2000 ft (610m) must be reduced by 4% for each 1000 ft (305 m) above sea level. In Canada, the input rating for altitudes from 2001 to 4500 ft (611 to 1372 m) above sea level must be derated by 10% by an authorized gas conversion station or dealer. For Canadian Installations from 2000 to 4500 ft (610 ---1372 m), use U.S.A. column 2001 to 3000 ft (611 to 914 m). 26 High Altitude Compensation, Propane Gas 460V Rated Heating Input (Btu/hr), Propane Gas at Installation Altitude Above Sea Level, U.S.A.* 0 to 2000 ft 2001 to 3000 ft* 3001 to 4000 ft 4001 to 5000 ft 5001 to 6000 ft (0--- 610 m) (611 to 914 m) (915 to 1219 m) (1220 to 1524 m) (1524 to 1829 m) 60000 53000 45900 45900 45800 45800 90000 79000 68900 68900 68600 68600 115000 103000 100400 98900 83000 83000 130000 116000 115500 111800 101300 100400 *In the U.S.A., the input rating for altitudes above 2000 ft (610m) must be reduced by 4% for each 1000 ft (305 m) above sea level. In Canada, the input rating for altitudes from 2001 to 4500 ft (611 to 1372 m) above sea level must be derated by 10% by an authorized gas conversion station or dealer. For Canadian Installations from 2000 to 4500 ft (610 ---1372 m), use U.S.A. column 2001 to 3000 ft (611 to 914 m). 48VG -- A Nameplate Input (Btu/hr) 27 28 15 - 45oF Low Stage, 20 - 50oF High Stage 48VG(A,N)24040 See notes on page 41. HEATING RISE RANGE UNIT High Black Orange Med-High2 Pink Med-Low1 Red Blue Low3 Medium4 WIRE COLOR MOTOR SPEED CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) 0.1 714 0.08 26 (15) 41 (23) 689 0.08 27 (15) 42 (23) 877 0.12 21 (12) 33 (18) 921 0.14 20 (11) 32 (18) 1291 0.31 15 (8) 23 (13) NA NA 489 0.06 38 (21) NA 597 0.06 31 (17) 49 (27) 779 0.12 24 (13) 37 (21) 829 0.14 23 (13) 35 (20) 1206 0.32 16 (9) 24 (13) NA NA 598 0.14 31 (17) 49 (27) 663 0.16 28 (16) 44 (24) 1081 0.34 17 (10) 27 (15) NA 698 0.13 27 (15) 42 (23) 754 0.15 25 (14) 39 (21) 1142 0.33 16 (9) 25 (14) 888 0.36 21 (12) 33 (18) 951 0.35 20 (11) 31 (17) NA 371 0.18 NA 485 0.17 39 (22) 582 0.17 32 (18) 50 (28) 1017 0.34 18 (10) 29 (16) NA NA ----- NA NA ----- NA NA NA NA NA 410 0.15 NA NA ----- NA NA NA 519 0.15 36 (20) NA ----- NA NA NA 352 0.05 NA 823 0.36 23 (13) 35 (20) NA NA ----- NA NA ----- NA NA ----- NA NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 ------------------------NA 0.2 525 0.07 36 (20) 753 0.37 25 (14) 39 (21) NA NA ----- NA NA ----- NA NA ----- NA NA 0.9 ----- DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 48VG -- A 668 0.37 28 (16) 44 (24) NA NA ----- NA NA ----- NA NA ----- NA NA 1 ----- 29 25 - 55oF Low Stage, 25 - 55oF High Stage 48VG(A,N)24060 See notes on page 41. HEATING RISE RANGE UNIT High Black Orange Med-High4 Pink Med-Low3 Red Blue Low1 Medium2 WIRE COLOR MOTOR SPEED CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) NA 37 (20) NA 34 (19) 829 0.14 34 (19) 54 (30) 1171 0.30 921 0.14 31 (17) 48 (27) 1229 0.28 38 (21) 1206 0.32 NA NA NA 692 0.10 41 (23) 777 0.09 37 (20) 36 (20) 1291 0.31 NA NA NA 0.2 597 0.06 48 (27) 0.1 689 0.08 41 (23) NA 48VG -- A 980 0.32 29 (16) 45 (25) 1017 0.34 28 (16) 44 (24) NA 1049 0.31 27 (15) 42 (24) 1081 0.34 26 (15) 41 (23) NA 1105 0.30 26 (14) 40 (22) 1142 0.33 25 (14) 39 (22) NA NA 318 0.12 NA NA 582 0.17 49 (27) NA NA 465 0.11 NA NA 663 0.16 43 (24) 754 0.15 38 (21) NA 583 0.10 49 (27) NA NA 913 0.33 31 (17) 49 (27) 951 0.35 30 (17) 47 (26) NA NA 485 0.17 NA NA ----- NA NA 838 0.33 34 (19) 53 (29) 888 0.36 32 (18) 50 (28) NA NA 371 0.18 NA NA ----- NA NA NA NA NA 668 0.37 43 (24) NA 753 0.37 38 (21) NA 823 0.36 35 (19) 54 (30) 516 0.33 55 (31) NA NA ----- NA NA ----- NA NA 1 ----- 679 0.34 42 (23) NA NA ----- NA NA ----- NA NA 0.9 ----- 775 0.34 37 (20) NA NA ----- NA NA ----- NA NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 489 352 --------0.06 0.05 --------- DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 30 15 - 45oF Low Stage, 20 - 50oF High Stage 48VG(A,N)30040 See notes on page 41. HEATING RISE RANGE UNIT High Black Orange Med-High2 Pink Med-Low1 Red Blue Low3 Medium4 WIRE COLOR MOTOR SPEED CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) NA 670 0.12 28 (16) 43 (24) 698 0.13 27 (15) 42 (23) 1012 0.24 19 (10) 29 (16) 1382 0.50 NA 21 (12) NA 765 0.12 25 (14) 38 (21) 779 0.12 24 (13) 37 (21) 1069 0.23 18 (10) 27 (15) 1460 0.52 NA 20 (11) NA NA NA 22 (12) NA 586 0.13 32 (18) 50 (28) 598 0.14 31 (17) 49 (27) 937 0.24 20 (11) 31 (17) 1301 0.48 NA NA NA 724 0.26 26 (14) 40 (22) 1003 0.42 19 (10) 29 (16) NA 786 0.26 24 (13) 37 (21) 1114 0.44 17 (9) 26 (15) NA 870 0.25 22 (12) 33 (19) 1209 0.46 16 (9) 24 (13) ----NA 410 0.15 519 0.15 36 (20) NA NA ----- NA NA NA NA NA 299 0.14 NA NA NA 466 0.13 40 (22) NA NA 626 0.27 30 (17) 47 (26) 890 0.40 21 (12) 33 (18) NA NA ----- NA NA ----- NA NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 ------------------------- 0.1 714 0.08 26 (15) 41 (23) 831 0.11 23 (13) 35 (19) 877 0.12 21 (12) 33 (18) 1139 0.22 17 (9) 26 (14) 1531 0.53 0.2 525 0.07 36 (20) NA 629 0.35 30 (17) 46 (26) NA NA 381 0.28 NA NA ----- NA NA ----- NA NA 1 ----- 764 0.37 25 (14) 38 (21) 512 0.27 37 (20) NA NA ----- NA NA ----- NA NA 0.9 ----- DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 48VG -- A 31 25 - 55oF Low Stage, 25 - 55oF High Stage 48VG(A,N)30060 See notes on page 41. HEATING RISE RANGE UNIT High Black Orange Med-High4 Pink Med-Low1 Red Blue Low3 Medium2 WIRE COLOR MOTOR SPEED CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) 38 (21) 1460 0.52 NA 30 (17) NA 29 (16) 1069 0.23 27 (15) 42 (23) 1171 0.30 NA 1012 0.24 28 (16) 44 (24) 1105 0.30 26 (14) 40 (22) 1382 0.50 NA 36 (20) 1531 0.53 NA 765 0.12 37 (21) 831 0.11 34 (19) 54 (30) 1139 0.22 25 (14) 39 (22) 1229 0.28 NA 670 0.12 43 (24) NA NA 32 (18) NA NA 0.2 692 0.10 41 (23) 0.1 777 0.09 37 (21) 37 (21) NA 870 0.25 33 (18) 51 (28) 980 0.32 29 (16) 45 (25) 1209 0.46 NA NA 466 0.13 NA 48VG -- A 34 (19) NA 937 0.24 30 (17) 47 (26) 1049 0.31 27 (15) 42 (23) 1301 0.48 NA 586 0.13 49 (27) NA NA NA NA 629 0.35 45 (25) NA 764 0.37 37 (21) NA NA 516 0.33 55 (31) 890 0.40 32 (18) 50 (28) NA NA 381 0.28 NA NA ----- NA NA 1 ----- 679 0.34 42 (23) NA NA 512 0.27 NA NA ----- NA NA 0.9 ----- 775 0.34 37 (21) NA 838 0.33 34 (19) 53 (29) 1003 0.42 28 (16) 44 (24) NA 913 0.33 31 (17) 49 (27) 1114 0.44 26 (14) 40 (22) NA NA ----- NA 626 0.27 46 (26) NA NA ----- NA 724 0.26 39 (22) 786 0.26 36 (20) NA NA 299 0.14 NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 583 465 318 ------0.10 0.11 0.12 ------49 NA NA NA NA NA (27) DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 32 25 - 55oF Low Stage, 25 - 55oF High Stage 48VG(A,N)36060 See notes on page 41. HEATING RISE RANGE UNIT High Black Orange Med-High2 Pink Med-Low1 Red Blue Low3 Medium4 WIRE COLOR MOTOR SPEED CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) NA 37 (21) 1423 0.31 NA 31 (17) 36 (20) 1466 0.30 NA 30 (17) 38 (21) 1198 0.21 NA NA 864 0.10 33 (18) 52 (29) 1169 0.17 934 0.10 31 (17) 48 (26) 1213 0.16 37 (20) 1251 0.19 NA NA NA 0.2 624 0.05 46 (25) 0.1 694 0.05 41 (23) 32 (18) NA 810 0.11 35 (20) 55 (31) 1110 0.17 26 (14) 40 (22) 1149 0.21 25 (14) 39 (22) 1384 0.33 NA 1016 0.20 28 (16) 44 (24) 1066 0.24 27 (15) 42 (23) 1308 0.35 1065 0.19 27 (15) 42 (23) 1104 0.23 26 (14) 40 (22) 1343 0.34 33 (18) 34 (19) NA NA NA NA 698 0.13 41 (23) NA 745 0.12 38 (21) NA 35 (20) NA 964 0.21 30 (16) 46 (26) 1017 0.25 28 (16) 44 (24) 1263 0.36 NA 649 0.14 44 (24) NA 37 (20) NA 923 0.22 31 (17) 48 (27) 970 0.26 29 (16) 46 (25) 1219 0.37 NA 571 0.14 50 (28) NA 38 (21) NA 878 0.23 33 (18) 51 (28) 932 0.27 31 (17) 48 (27) 1183 0.38 NA 525 0.15 54 (30) NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 533 460 383 328 ----0.06 0.07 0.07 0.08 ----54 NA NA NA NA NA (30) 820 0.24 35 (19) 54 (30) 892 0.28 32 (18) 50 (28) 1145 0.40 25 (14) 39 (22) NA NA 486 0.16 NA NA 0.9 ----- DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 48VG -- A 839 0.29 34 (19) 53 (29) 1106 0.41 26 (14) 40 (22) NA 777 0.25 37 (20) NA NA 428 0.17 NA NA 1 ----- 33 35 - 65oF Low Stage, 35 - 65oF High Stage 48VG(A,N)36090 See notes on page 41. HEATING RISE RANGE UNIT High Black Orange Med-High4 Pink Med-Low1 Red Blue Low3 Medium2 WIRE COLOR MOTOR SPEED 0.29 Low Stage Heat Rise (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) oF BHP 48 (26) 1423 0.31 NA 47 (26) NA 46 (26) NA 0.30 46 (26) 1466 0.30 NA NA 54 (30) 1451 1198 0.21 36 (20) 56 (31) 1415 1251 0.19 49 (27) NA 49 (27) 1384 0.33 NA 0.31 1149 0.21 37 (21) 59 (33) 1372 NA 52 (29) NA 52 (29) 1308 0.35 NA 1066 0.24 40 (22) 63 (35) 1287 248. 59 NA 48VG -- A 50 (28) NA 51 (28) 1343 0.34 NA 0.32 1104 0.23 39 (22) 61 (34) 1327 NA 53 (30) NA 54 (30) 1263 0.36 NA 0.35 35 (20) 56 (31) 1219 0.37 35 (20) 55 (31) 0.36 NA 37 (20) 58 (32) 1183 0.38 36 (20) 57 (32) 0.37 1168 NA 1212 NA 1249 NA NA 525 0.15 932 0.27 46 (26) NA NA 571 0.14 970 0.26 44 (25) 1017 0.25 42 (23) NA NA 649 0.14 NA NA 698 0.13 62 (34) NA NA 745 0.12 58 (32) NA 810 0.11 53 (29) NA 864 0.10 50 (28) NA NA NA CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 823 747 669 636 558 513 0.10 0.11 0.12 0.13 0.13 0.14 52 58 64 NA NA NA (29) (32) (36) 0.2 971 0.11 44 (25) 0.1 1097 0.12 39 (22) 61 (34) 934 0.10 46 (26) 38 (21) 60 (33) 1145 0.40 38 (21) 59 (33) 0.38 1130 NA 892 0.28 48 (27) NA NA 486 0.16 NA NA 0.9 456 0.15 DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 39 (22) 62 (34) 1106 0.41 39 (22) 61 (34) 0.39 1094 NA 839 0.29 51 (28) NA NA 428 0.17 NA NA 1 412 0.16 34 25 - 55oF Low Stage, 25 - 55oF High Stage 48VG(A,N)42060 See notes on page 41. HEATING RISE RANGE UNIT High Black Orange Med-High2 Pink Med-Low1 Red Blue Low3 Medium4 WIRE COLOR MOTOR SPEED Low Stage Heat Rise (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) 31 (17) 1590 0.43 NA 28 (16) NA 27 (15) NA 31 (17) 1633 0.41 NA 0.29 BHP 0.30 38 (21) 1415 oF NA 37 (20) 1451 1026 0.14 28 (15) 43 (24) 1169 0.17 1076 0.13 27 (15) 41 (23) 1213 0.16 NA NA NA CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM 0.2 624 0.05 46 (25) 0.1 694 0.05 41 (23) 29 (16) NA 32 (18) 1552 0.44 NA 0.31 972 0.15 29 (16) 46 (25) 1110 0.17 26 (14) 40 (22) 1372 NA 29 (16) NA 34 (18) 1518 0.45 NA 0.32 918 0.15 31 (17) 48 (27) 1065 0.19 27 (15) 42 (23) 1327 NA 30 (17) NA 35 (19) 1483 0.47 NA 872 0.17 33 (18) 51 (28) 1016 0.20 28 (16) 44 (24) 1287 248. 59 NA 31 (17) NA 36 (20) 1444 0.48 NA 0.35 827 0.18 35 (19) 54 (30) 964 0.21 30 (16) 46 (26) 1249 NA 878 0.23 33 (18) 51 (28) 1168 923 0.22 31 (17) 48 (27) 1212 32 (18) NA 37 (20) 1406 0.49 NA 32 (18) NA 38 (21) 1372 0.50 NA 0.37 NA NA 0.36 714 0.20 40 (22) NA 771 0.18 37 (21) NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 533 460 383 328 ----0.06 0.07 0.07 0.08 ----54 NA NA NA NA NA (30) 33 (18) NA 25 (14) 39 (22) 1340 0.51 0.38 820 0.24 35 (19) 54 (30) 1130 NA 666 0.21 43 (24) NA NA 0.9 ----- DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 48VG -- A 34 (19) NA 26 (15) 41 (23) 1303 0.53 0.39 1094 NA 777 0.25 37 (20) NA 611 0.22 47 (26) NA NA 1 ----- 35 35 - 65oF Low Stage, 35 - 65oF High Stage 48VG(A,N)42090 See notes on page 41. HEATING RISE RANGE UNIT High4 Black Orange Med-High2 Pink Med-Low1 Red Blue Low3 Medium WIRE COLOR MOTOR SPEED 0.29 BHP Low Stage Heat Rise (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) oF 54 (30) 1451 NA 42 (24) 41 (23) 48 (26) 1590 0.43 NA 43 (24) NA 49 (27) 1552 0.44 NA 0.31 1149 0.21 37 (21) 59 (33) 1372 1198 0.21 36 (20) 56 (31) 1415 0.30 NA 45 (25) NA 52 (29) 1483 0.47 NA 1066 0.24 40 (22) 63 (35) 1287 248. 59 NA 48VG -- A 44 (25) NA 51 (28) 1518 0.45 NA 0.32 1104 0.23 39 (22) 61 (34) 1327 NA 872 0.17 49 (27) 47 (26) NA 54 (30) 1444 0.48 NA 0.35 48 (27) NA 35 (20) 56 (31) 1406 0.49 0.36 NA 49 (27) NA 37 (20) 58 (32) 1372 0.50 0.37 1168 NA 1212 NA 1249 NA 714 0.20 60 (33) 932 0.27 46 (26) NA 771 0.18 56 (31) 970 0.26 44 (25) 1017 0.25 42 (23) NA 827 0.18 52 (29) NA NA 918 0.15 47 (26) NA 972 0.15 44 (25) NA 1026 0.14 42 (23) NA NA NA NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 823 747 669 636 558 513 0.10 0.11 0.12 0.13 0.13 0.14 52 58 64 NA NA NA (29) (32) (36) 0.2 971 0.11 44 (25) NA 46 (26) 1633 0.41 NA NA CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM 0.1 1097 0.12 39 (22) 61 (34) 1076 0.13 40 (22) 63 (35) 1251 0.19 50 (28) NA 38 (21) 60 (33) 1340 0.51 0.38 1130 NA 892 0.28 48 (27) NA 666 0.21 64 (36) NA NA 0.9 456 0.15 DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 52 (29) NA 39 (22) 62 (34) 1303 0.53 0.39 1094 NA 839 0.29 51 (28) NA NA 611 0.22 NA NA 1 412 0.16 36 35 - 65oF Low Stage, 35 - 65oF High Stage 48VG(A,N)48090 See notes on page 41. HEATING RISE RANGE UNIT High Black Orange Med-High2 Pink Med-Low1 Red Blue Low3 Medium4 WIRE COLOR MOTOR SPEED CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) NA 41 (23) 1837 0.57 NA 37 (20) 40 (22) 1854 0.56 NA 36 (20) 52 (29) 1650 0.44 NA NA 50 (28) 1686 0.42 38 (21) NA 42 (23) 1781 0.60 NA 38 (21) NA 43 (24) 1784 0.59 NA 1121 0.23 38 (21) 60 (33) 1191 0.25 36 (20) 57 (31) 1576 0.46 39 (22) NA 44 (24) 1720 0.62 NA 1066 0.24 40 (22) 63 (35) 1139 0.26 38 (21) 59 (33) 1544 0.48 1050 0.29 41 (23) 64 (36) 1468 0.51 1091 0.28 39 (22) 62 (34) 1503 0.49 40 (22) NA 45 (25) 1698 0.63 41 (23) NA 46 (26) 1655 0.64 NA NA NA NA 974 0.26 44 (25) 1027 0.25 42 (23) NA 41 (23) NA 47 (26) 1625 0.66 NA 43 (24) NA 48 (27) 1578 0.67 NA NA 44 (24) NA 50 (28) 1532 0.67 NA 1356 0.55 NA 1393 0.53 NA 1433 0.52 NA 839 0.29 51 (28) NA NA 1 ----- 895 0.32 48 (27) NA 887 0.28 48 (27) NA NA 0.9 ----- 952 0.31 45 (25) 1001 0.30 43 (24) NA 942 0.27 46 (25) NA 1177 0.21 36 (20) 57 (32) 1240 0.24 35 (19) 54 (30) 1617 0.45 NA 1229 0.20 35 (19) 55 (30) 1299 0.23 NA NA NA NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 703 587 501 449 380 340 0.09 0.09 0.09 0.10 0.11 0.12 61 NA NA NA NA NA (34) 0.2 904 0.10 48 (26) NA 53 (29) 1340 0.22 NA 0.1 1067 0.12 40 (22) 63 (35) 1271 0.19 DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 48VG -- A 37 30 - 60oF Low Stage, 30 - 60oF High Stage 48VG(A,N)48115 See notes on page 41. HEATING RISE RANGE UNIT High4 Black Orange Med-High Pink Med-Low3 Red Blue Low1 Medium2 WIRE COLOR MOTOR SPEED CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) 1650 0.44 34 (19) 53 (29) 1837 0.57 30 (17) 47 (26) 1900 0.61 1686 0.42 33 (18) 52 (29) 1854 0.56 30 (17) 47 (26) 1934 0.59 46 (25) NA NA 45 (25) 1299 0.23 43 (24) 1340 0.22 42 (23) NA NA NA NA 0.2 1229 0.20 45 (25) 0.1 1271 0.19 44 (24) 1617 0.45 35 (19) 54 (30) 1781 0.60 31 (17) 49 (27) 1855 0.62 30 (17) 47 (26) NA 1240 0.24 45 (25) NA 1544 0.48 36 (20) 56 (31) 1720 0.62 32 (18) 51 (28) 1778 0.65 31 (17) 49 (27) NA 1139 0.26 49 (27) NA 48VG -- A 1576 0.46 35 (20) 55 (31) 1784 0.59 31 (17) 49 (27) 1815 0.64 31 (17) 48 (27) NA 1191 0.25 47 (26) NA 1503 0.49 37 (21) 58 (32) 1698 0.63 33 (18) 51 (28) 1737 0.67 32 (18) 50 (28) NA 1091 0.28 51 (28) NA 1468 0.51 38 (21) 59 (33) 1655 0.64 34 (19) 53 (29) 1695 0.68 33 (18) 51 (28) NA 1050 0.29 53 (30) NA NA 1532 0.67 36 (20) 57 (32) 1528 0.68 37 (20) 57 (32) NA 1578 0.67 35 (20) 55 (31) 1606 0.70 35 (19) 54 (30) NA 1625 0.66 34 (19) 53 (30) 1656 0.70 34 (19) 52 (29) NA NA 895 0.32 NA NA 1 839 0.29 1356 0.55 41 (23) NA 952 0.31 59 (33) NA NA 0.9 887 0.28 1393 0.53 40 (22) 1433 0.52 39 (22) NA 1001 0.30 56 (31) NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 1177 1121 1066 1027 974 942 0.21 0.23 0.24 0.25 0.26 0.27 47 50 52 54 57 59 (26) (28) (29) (30) (32) (33) DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 38 35 - 65oF Low Stage, 35 - 65oF High Stage 48VG(A,N)48130 See notes on page 41. HEATING RISE RANGE UNIT High4 Black Orange Med-High Pink Med-Low3 Red Blue Low1 Medium2 WIRE COLOR MOTOR SPEED CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) 1650 0.44 38 (21) 58 (32) 1837 0.57 NA 52 (29) 1900 0.61 1686 0.42 37 (21) 57 (32) 1854 0.56 NA 52 (29) 1934 0.59 50 (28) NA NA 50 (28) 1299 0.23 48 (27) 1340 0.22 47 (26) NA NA NA NA 0.2 1229 0.20 51 (28) 0.1 1271 0.19 49 (27) 52 (29) NA 1617 0.45 39 (22) 59 (33) 1781 0.60 35 (20) 54 (30) 1855 0.62 NA 1240 0.24 51 (28) NA 1576 0.46 40 (22) 61 (34) 1784 0.59 35 (20) 54 (30) 1815 0.64 35 (19) 53 (29) NA 1191 0.25 53 (29) NA 1544 0.48 41 (23) 62 (35) 1720 0.62 36 (20) 56 (31) 1778 0.65 35 (20) 54 (30) NA 1139 0.26 55 (31) NA 1503 0.49 42 (23) 64 (35) 1698 0.63 37 (20) 56 (31) 1737 0.67 36 (20) 55 (31) NA 1091 0.28 57 (32) NA 1468 0.51 43 (24) 65(3 6) 1655 0.64 38 (21) 58 (32) 1695 0.68 37 (21) 57 (31) NA 1050 0.29 60 (33) NA NA 1532 0.67 41 (23) 63 (35) 1528 0.68 41 (23) 63 (35) NA 1578 0.67 40 (22) 61 (34) 1606 0.70 39 (22) 60 (33) NA 1625 0.66 39 (21) 59 (33) 1656 0.70 38 (21) 58 (32) NA NA 895 0.32 NA NA 1 839 0.29 1356 0.55 46 (26) NA NA 952 0.31 NA NA 0.9 887 0.28 1393 0.53 45 (25) 1433 0.52 44 (24) NA 1001 0.30 63 (35) NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 1177 1121 1066 1027 974 942 0.21 0.23 0.24 0.25 0.26 0.27 53 56 59 61 64 NA (30) (31) (33) (34) (36) DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 48VG -- A 39 35 - 65oF Low Stage, 35 - 65oF High Stage 48VG(A,N)60090 See notes on page 41. HEATING RISE RANGE UNIT High Black Orange Med-High2 Pink Med-Low1 Red Blue Low3 Medium4 WIRE COLOR MOTOR SPEED CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) NA 37 (20) 1990 0.63 NA NA 36 (20) 2020 0.62 NA NA 52 (29) 1844 0.52 NA NA 50 (28) 1878 0.50 NA NA 37 (21) 1956 0.66 NA 36 (20) 35 (20) 48VG -- A NA 39 (22) 1872 0.69 NA 1066 0.24 40 (22) 63 (35) 1139 0.26 38 (21) 59 (33) 1731 0.56 NA 38 (21) 1912 0.67 NA 1121 0.23 38 (21) 60 (33) 1191 0.25 36 (20) 57 (31) 1762 0.54 1050 0.29 41 (23) 64 (36) 1655 0.59 1091 0.28 39 (22) 62 (34) 1693 0.57 37 (20) NA 40 (22) 1842 0.70 37 (21) NA 41 (23) 1802 0.71 NA NA NA NA 974 0.26 44 (25) 1027 0.25 42 (23) NA 38 (21) NA 42 (23) 1760 0.73 NA 39 (22) NA 43 (24) 1719 0.74 NA NA 41 (23) NA 44 (24) 1643 0.72 NA 1532 0.63 NA 1570 0.64 NA 1616 0.60 NA 839 0.29 51 (28) NA NA 1 ----- 895 0.32 48 (27) NA 887 0.28 48 (27) NA NA 0.9 ----- 952 0.31 45 (25) 1001 0.30 43 (24) NA 942 0.27 46 (25) NA 1177 0.21 36 (20) 57 (32) 1240 0.24 35 (19) 54 (30) 1805 0.53 NA 1229 0.20 35 (19) 55 (30) 1299 0.23 NA NA NA NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 703 587 501 449 380 340 0.09 0.09 0.09 0.10 0.11 0.12 61 NA NA NA NA NA (34) 0.2 904 0.10 48 (26) NA 53 (29) 1340 0.22 NA 0.1 1067 0.12 40 (22) 63 (35) 1271 0.19 DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 40 30 - 60oF Low Stage, 30 - 60oF High Stage 48VG(A,N)60115 See notes on page 41. HEATING RISE RANGE UNIT High4 Black Orange Med-High2 Pink Med-Low3 Red Blue Low1 Medium WIRE COLOR MOTOR SPEED CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) 1650 0.44 34 (19) 53 (29) 1844 0.52 30 (17) 47 (26) 1900 0.61 1686 0.42 33 (18) 52 (29) 1878 0.50 30 (17) 46 (26) 1934 0.59 46 (25) NA NA 45 (25) 1299 0.23 43 (24) 1340 0.22 42 (23) NA NA NA NA 0.2 1229 0.20 45 (25) 0.1 1271 0.19 44 (24) 1617 0.45 35 (19) 54 (30) 1805 0.53 31 (17) 48 (27) 1855 0.62 30 (17) 47 (26) NA 1240 0.24 45 (25) NA 1576 0.46 35 (20) 55 (31) 1762 0.54 32 (18) 49 (27) 1815 0.64 31 (17) 48 (27) NA 1191 0.25 47 (26) NA 1544 0.48 36 (20) 56 (31) 1731 0.56 32 (18) 50 (28) 1778 0.65 31 (17) 49 (27) NA 1139 0.26 49 (27) NA 1503 0.49 37 (21) 58 (32) 1693 0.57 33 (18) 51 (29) 1737 0.67 32 (18) 50 (28) NA 1091 0.28 51 (28) NA 1468 0.51 38 (21) 59 (33) 1655 0.59 34 (19) 53 (29) 1695 0.68 33 (18) 51 (28) NA 1050 0.29 53 (30) NA NA 1532 0.63 36 (20) 57 (32) 1528 0.68 37 (20) 57 (32) NA 1570 0.64 36 (20) 55 (31) 1606 0.70 35 (19) 54 (30) NA 1616 0.60 35 (19) 54 (30) 1656 0.70 34 (19) 52 (29) NA NA 895 0.32 NA NA 1 839 0.29 1356 0.55 41 (23) NA 952 0.31 59 (33) NA NA 0.9 887 0.28 1393 0.53 40 (22) 1433 0.52 39 (22) NA 1001 0.30 56 (31) NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 1177 1121 1066 1027 974 942 0.21 0.23 0.24 0.25 0.26 0.27 47 50 52 54 57 59 (26) (28) (29) (30) (32) (33) DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 48VG -- A 41 35 - 65oF Low Stage, 35 - 65oF High Stage 48VG(A,N)60130 High4 Black Orange Med-High2 Pink Med-Low3 Red Blue Low1 Medium WIRE COLOR MOTOR SPEED CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) CFM BHP Low Stage Heat Rise oF (oC) High Stage Heat Rise oF (oC) Notes: 1 Factory-shipped low stage cooling speed 2 Factory-shipped high stage cooling speed 3 Factory-shipped low stage gas heating speed 4 Factory-shipped high stage gas heating speed Allowable High Stage Enhanced Dehumidification Cooling Speed ”NA” = Not allowed for particular heating speed HEATING RISE RANGE UNIT 1650 0.44 38 (21) 58 (32) 1844 0.52 1686 0.42 37 (21) 57 (32) 1878 0.50 NA 50 (28) NA 50 (28) 52 (29) 1900 0.61 NA NA NA 1299 0.23 48 (27) 1340 0.22 47 (26) 51 (28) 1934 0.59 NA NA NA 0.2 1229 0.20 51 (28) 0.1 1271 0.19 49 (27) 52 (29) NA 1617 0.45 39 (22) 59 (33) 1805 0.53 35 (19) 53 (30) 1855 0.62 NA 1240 0.24 51 (28) NA 1544 0.48 41 (23) 62 (35) 1731 0.56 36 (20) 55 (31) 1778 0.65 35 (20) 54 (30) NA 1139 0.26 55 (31) NA 48VG -- A 1576 0.46 40 (22) 61 (34) 1762 0.54 36 (20) 54 (30) 1815 0.64 35 (19) 53 (29) NA 1191 0.25 53 (29) NA 1503 0.49 42 (23) 64 (35) 1693 0.57 37 (21) 57 (31) 1737 0.67 36 (20) 55 (31) NA 1091 0.28 57 (32) NA 1468 0.51 43 (24) 65 (36) 1655 0.59 38 (21) 58 (32) 1695 0.68 37 (21) 57 (31) NA 1050 0.29 60 (33) NA NA 1532 0.63 41 (23) 63 (35) 1528 0.68 41 (23) 63 (35) NA 1570 0.64 40 (22) 61 (34) 1606 0.70 39 (22) 60 (33) NA 1616 0.60 39 (22) 59 (33) 1656 0.70 38 (21) 58 (32) NA NA 895 0.32 NA NA 1 839 0.29 1356 0.55 46 (26) NA NA 952 0.31 NA NA 0.9 887 0.28 1393 0.53 45 (25) 1433 0.52 44 (24) NA 1001 0.30 63 (35) NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 1177 1121 1066 1027 974 942 0.21 0.23 0.24 0.25 0.26 0.27 53 56 59 61 64 NA (30) (31) (33) (34) (36) DRY COIL AIR DELIVERY* -- HORIZONTAL AND DOWNFLOW DISCHARGE - UNIT 48VG--A 208/230 VAC MODELS (CONT) 42 See notes on page 46. 35 - 65oF 25 - 55oF 48VG(A,N)36060 48VG(A,N)36090 HEATING RISE RANGE UNIT WIRE COLOR Blue Pink Red Orange Black Blue Pink Red Orange Black MOTOR SPEED Low1 Med-Low Medium3 Med-High2 High Low1 Med-Low Medium Med-High2 High3 BHP 0.29 47 (26) BHP Heat Rise oF (oC) 48 (27) 0.30 50 (28) 0.31 NA 51 (28) 0.32 1065 0.19 64 (35) 1104 0.23 62 (34) 1327 NA 1110 0.17 61 (34) 1149 0.21 59 (33) 1372 NA 1169 0.17 58 (32) 1198 0.21 57 (32) 1415 NA 918 0.15 NA NA NA NA 1212 NA 1249 54 (30) 0.35 970 0.26 1017 0.25 1066 0.24 64 (35) 1287 248.5 9 53 (29) 56 (31) 0.36 NA NA NA 923 0.22 NA 771 0.18 964 0.21 NA 827 0.18 1016 0.20 NA 872 0.17 NA 58 (32) 0.37 1168 NA 932 0.27 NA 878 0.23 NA 714 0.20 NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 810 745 698 649 571 525 0.11 0.12 0.13 0.14 0.14 0.15 55 NA NA NA NA NA (30) 972 918 872 827 771 714 0.15 0.15 0.17 0.18 0.18 0.20 46 48 51 54 NA NA (25) (27) (28) (30) 1110 1065 1016 964 923 878 0.17 0.19 0.20 0.21 0.22 0.23 40 42 44 46 48 51 (22) (23) (24) (26) (27) (28) 1149 1104 1066 1017 970 932 0.21 0.23 0.24 0.25 0.26 0.27 39 40 42 44 46 48 (21) (22) (23) (24) (25) (26) 1372 1327 1287 1249 1212 1168 248.5 0.31 0.32 0.35 0.36 0.37 9 32 33 35 36 37 38 (18) (19) (19) (20) (20) (21) 810 745 698 649 571 525 0.11 0.12 0.13 0.14 0.14 0.15 972 0.15 NA 1026 0.14 NA 1076 0.13 63 (35) 1213 0.16 56 (31) 1251 0.19 54 (30) 1451 31 (17) 864 0.10 0.30 0.2 864 0.10 51 (29) 1026 0.14 43 (24) 1169 0.17 38 (21) 1198 0.21 37 (21) 1415 Heat Rise (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM 31 (17) 934 0.10 0.29 CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM oF 0.1 934 0.10 48 (26) 1076 0.13 41 (23) 1213 0.16 37 (20) 1251 0.19 36 (20) 1451 DRY COIL AIR DELIVERY -- HORIZONTAL AND DOWNFLOW DISCHARGE - 48VG--A 460 VAC MODELS 48VG -- A 60 (33) 0.38 1130 NA 892 0.28 NA 820 0.24 NA 666 0.21 NA 39 (22) 486 0.16 0.38 62 (35) 0.39 1094 NA 839 0.29 NA 777 0.25 NA 611 0.22 NA 41 (23) 428 0.17 0.39 839 0.29 53 (29) 1094 NA NA 777 0.25 611 0.22 666 0.21 NA NA NA 820 0.24 54 (30) 892 0.28 50 (28) 1130 1 428 0.17 0.9 486 0.16 43 See notes on page 46. 48VG(A,N)42090 48VG(A,N)42060 35 - 65oF 25 - 55oF Orange Black High3 Blue Low1 Med-High2 Black High Red Orange Med-High2 Medium Red Medium3 Pink Pink Med-Low Med-Low Blue Low1 Heat Rise (oC) CFM BHP Heat Rise oF (oC) 47 (26) 1633 0.41 42 (23) 0.29 BHP 48 (27) 1590 0.43 43 (24) 50 (28) 1552 0.44 44 (24) 0.31 1110 0.17 61 (34) 1149 0.21 59 (33) 1372 1169 0.17 58 (32) 1198 0.21 57 (32) 1415 0.30 NA NA oF 1552 0.44 29 (16) 972 0.15 1590 0.43 28 (16) 1026 0.14 1633 0.41 27 (15) 1076 0.13 63 (35) 1213 0.16 56 (31) 1251 0.19 54 (30) 1451 32 (18) 0.31 31 (17) 0.30 972 0.15 46 (25) 1110 0.17 40 (22) 1149 0.21 39 (21) 1372 31 (17) 0.29 BHP 1026 0.14 43 (24) 1169 0.17 38 (21) 1198 0.21 37 (21) 1415 High Stage Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF(oC) CFM BHP Heat Rise oF (oC) CFM 1076 0.13 41 (23) 1213 0.16 37 (20) 1251 0.19 36 (20) 1451 CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM 51 (28) 1518 0.45 45 (25) 0.32 1065 0.19 64 (35) 1104 0.23 62 (34) 1327 NA 1518 0.45 29 (16) 918 0.15 33 (19) 0.32 918 0.15 48 (27) 1065 0.19 42 (23) 1104 0.23 40 (22) 1327 48VG -- A 54 (30) 1444 0.48 47 (26) 0.35 56 (31) 1406 0.49 48 (27) 0.36 NA 58 (32) 1372 0.50 50 (28) 0.37 1168 NA 1212 NA NA 1249 1017 0.25 1066 0.24 64 (35) 1287 248.5 9 53 (29) 1483 0.47 46 (25) NA 878 0.23 NA 1372 0.50 32(18 ) 714 0.20 38 (21) 0.37 932 0.27 NA NA 923 0.22 NA 1406 0.49 32 (18) 771 0.18 37 (20) 0.36 NA NA 878 0.23 51 (28) 932 0.27 48 (26) 1168 NA 923 0.22 48 (27) 970 0.26 46 (25) 1212 60 (33) 1340 0.51 51 (28) 0.38 1130 NA 892 0.28 NA 820 0.24 NA 1340 0.51 33 (18) 666 0.21 39 (22) 0.38 820 0.24 54 (30) 892 0.28 50 (28) 1130 666 0.21 714 0.20 771 0.18 970 0.26 964 0.21 NA 1444 0.48 31 (17) 827 0.18 36 (20) 0.35 827 0.18 54 (30) 964 0.21 46 (26) 1017 0.25 44 (24) 1249 1016 0.20 NA 1483 0.47 30 (17) 872 0.17 35 (19) 872 0.17 51 (28) 1016 0.20 44 (24) 1066 0.24 42 (23) 1287 248.5 9 DRY COIL AIR DELIVERY -- HORIZONTAL AND DOWNFLOW DISCHARGE - 48VG--A 460 VAC MODELS 62 (35) 1303 0.53 52 (29) 0.39 1094 NA 839 0.29 NA 777 0.25 NA 1303 0.53 34 (19) 611 0.22 41 (23) 0.39 839 0.29 53 (29) 1094 NA 777 0.25 NA 611 0.22 44 See notes on page 46. 30 - 60oF 35 - 65oF 48VG(A,N)48090 48VG(A,N)48115 HEATING RISE RANGE UNIT Blue Low1 Red Orange Black Medium2 Med-High High3 Pink Black High Med-Low Orange Med-High Pink Med-Low3 Red Blue Low1 Medium2 WIRE COLOR MOTOR SPEED CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) 1341 0.26 NA 1617 0.45 53 (30) 1781 0.60 48 (27) 2065 0.75 42 (23) NA 1229 0.20 NA 1389 0.26 NA 1650 0.44 52 (29) 1837 0.57 47 (26) 2088 0.74 41 (23) NA 1271 0.19 NA 1445 0.24 60 (33) 1686 0.42 51 (28) 1854 0.56 47 (26) 2131 0.72 40 (22) NA 0.2 1229 0.20 55 (31) 1389 0.26 49 (27) 1650 0.44 41 (23) 1837 0.57 37 (21) 2088 0.74 0.1 1271 0.19 54 (30) 1445 0.24 47 (26) 1686 0.42 40 (22) 1854 0.56 37 (20) 2131 0.72 1576 0.46 55 (30) 1784 0.59 48 (27) 2013 0.77 43 (24) NA 1281 0.28 NA 1544 0.48 56 (31) 1720 0.62 50 (28) 1982 0.79 44 (24) NA 1236 0.29 NA 1503 0.49 57 (32) 1698 0.63 51 (28) 1941 0.8 45 (25) NA 1189 0.3 NA 1468 0.51 59 (33) 1655 0.64 52 (29) 1888 0.81 46 (25) NA 1139 0.32 NA 1433 0.52 60 (33) 1625 0.66 53 (29) 1860 0.81 46 (26) NA 1072 0.33 NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 1177 1121 1066 1027 974 942 0.21 0.23 0.24 0.25 0.26 0.27 58 61 64 NA NA NA (32) (34) (35) 1341 1281 1236 1189 1139 1072 0.26 0.28 0.29 0.3 0.32 0.33 51 53 55 57 60 63 (28) (29) (31) (32) (33) (35) 1617 1576 1544 1503 1468 1433 0.45 0.46 0.48 0.49 0.51 0.52 42 43 44 45 46 47 (23) (24) (24) (25) (26) (26) 1781 1784 1720 1698 1655 1625 0.60 0.59 0.62 0.63 0.64 0.66 38 38 40 40 41 42 (21) (21) (22) (22) (23) (23) 2065 2013 1982 1941 1888 1860 0.75 0.77 0.79 0.8 0.81 0.81 35 36 37 NA NA NA (19) (20) (20) 1177 1121 1066 1027 974 942 0.21 0.23 0.24 0.25 0.26 0.27 DRY COIL AIR DELIVERY -- HORIZONTAL AND DOWNFLOW DISCHARGE - 48VG--A 460 VAC MODELS 48VG -- A NA 1532 0.67 56 (31) 1751 0.75 49 (27) NA 1356 0.55 NA 982 0.35 NA 1578 0.67 55 (30) 1785 0.79 48 (27) 1393 0.53 NA 1027 0.34 NA NA 1356 0.55 50 (28) 1532 0.67 44 (25) 1751 0.75 39 (22) 839 0.29 982 0.35 1027 0.34 NA NA NA 1393 0.53 49 (27) 1578 0.67 43 (24) 1785 0.79 38 (21) 887 0.28 1 839 0.29 0.9 887 0.28 45 See notes on page 46. 35 - 65oF 35 - 65oF 48VG(A,N)48130 48VG(A,N)60090 HEATING RISE RANGE UNIT Blue Low1 Red Orange Black Medium2 Med-High High Pink Black High3 Med-Low3 Orange Med-High Pink Med-Low Red Blue Low1 Medium2 WIRE COLOR MOTOR SPEED CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) NA 2088 0.74 NA NA NA 1650 0.44 58 (32) 1837 0.57 52 (29) 2088 0.74 46 (26) 1229 0.20 55 (31) 1389 0.26 49 (27) 1844 0.52 37 (20) 1990 0.63 NA 1686 0.42 57 (32) 1854 0.56 52 (29) 2131 0.72 45 (25) 1271 0.19 54 (30) 1445 0.24 47 (26) 1878 0.50 36 (20) 2020 0.62 NA NA 1389 0.26 1445 0.24 2131 0.72 1341 0.26 NA NA NA 1617 0.45 60 (33) 1781 0.60 54 (30) 2065 0.75 47 (26) 1177 0.21 58 (32) 1341 0.26 51 (28) 1805 0.53 38 (21) 1956 0.66 35 (19) 2065 0.75 NA 0.2 1229 0.20 0.1 1271 0.19 NA 1576 0.46 61 (34) 1784 0.59 54 (30) 2013 0.77 48 (27) 1121 0.23 61 (34) 1281 0.28 53 (29) 1762 0.54 39 (21) 1912 0.67 36 (20) 2013 0.77 NA 1281 0.28 NA 1139 0.32 60 (33) 1655 0.59 41 (23) 1802 0.71 38 (21) 1888 0.81 36 (20) 1189 0.3 57 (32) 1693 0.57 40 (22) 1842 0.70 37 (21) 1941 0.8 35 (19) 1072 0.33 63 (35) 1616 0.60 42 (23) 1760 0.73 39 (21) 1860 0.81 37 (20) NA NA NA 982 0.35 NA 1532 0.63 44 (25) 1643 0.72 41 (23) 1751 0.75 39 (22) NA 1570 0.64 43 (24) 1719 0.74 40 (22) 1785 0.79 38 (21) NA 1532 0.67 63 (35) 1751 0.75 55 (31) 839 0.29 NA 1356 0.55 NA 982 0.35 NA 1 839 0.29 1027 0.34 NA 1578 0.67 61 (34) 1785 0.79 54 (30) 887 0.28 NA NA 1625 0.66 59 (33) 1860 0.81 52 (29) 942 0.27 NA 1393 0.53 NA 1027 0.34 NA 0.9 887 0.28 1433 0.52 NA 1072 0.33 NA 1655 0.64 58 (32) 1888 0.81 51 (28) 974 0.26 1468 0.51 NA 1139 0.32 NA 1503 0.49 64 (36) 1698 0.63 57 (32) 1941 0.8 50 (28) 1027 0.25 NA 1189 0.3 NA 48VG -- A NA 1544 0.48 62 (35) 1720 0.62 56 (31) 1982 0.79 49 (27) 1066 0.24 64 (35) 1236 0.29 55 (31) 1731 0.56 39 (22) 1872 0.69 36 (20) 1982 0.79 NA 1236 0.29 NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 1177 1121 1066 1027 974 942 0.21 0.23 0.24 0.25 0.26 0.27 DRY COIL AIR DELIVERY -- HORIZONTAL AND DOWNFLOW DISCHARGE - 48VG--A 460 VAC MODELS 46 Notes: 1 Factory-shipped low stage cooling speed 2 Factory-shipped high stage cooling speed 3 Factory-shipped low gas heating speed ”NA” = Not allowed for particular heating speed 35 - 65oF 30 - 60oF 48VG(A,N)60115 48VG(A,N)60130 HEATING RISE RANGE UNIT Blue Low1 Red Orange Black Medium2 Med-High High3 Pink Black High3 Med-Low Orange Med-High Pink Med-Low Red Blue Low1 Medium2 WIRE COLOR MOTOR SPEED CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) CFM BHP Heat Rise oF (oC) NA 1389 0.26 NA 1844 0.52 52 (29) 1990 0.63 48 (27) 2088 0.74 46 (26) NA 1445 0.24 NA 1878 0.50 51 (28) 2020 0.62 48 (26) 2131 0.72 45 (25) 1805 0.53 53 (30) 1956 0.66 49 (27) 2065 0.75 47 (26) NA 1341 0.26 NA NA 1762 0.54 55 (30) 1912 0.67 50 (28) 2013 0.77 48 (27) NA 1281 0.28 NA 1762 0.54 49 (27) 1912 0.67 45 (25) 2013 0.77 43 (24) 1121 0.23 NA 1805 0.53 48 (27) 1956 0.66 44 (24) 2065 0.75 42 (23) 1177 0.21 NA NA 1844 0.52 47 (26) 1990 0.63 43 (24) 2088 0.74 41 (23) 1229 0.20 1389 0.26 1445 0.24 60 (33) 1878 0.50 46 (26) 2020 0.62 43 (24) 2131 0.72 40 (22) 1271 0.19 NA 1281 0.28 NA NA 1731 0.56 56 (31) 1872 0.69 51 (29) 1982 0.79 49 (27) NA 1236 0.29 NA 1731 0.56 50 (28) 1872 0.69 46 (26) 1982 0.79 44 (24) 1066 0.24 NA 1236 0.29 NA 1693 0.57 57 (32) 1842 0.70 52 (29) 1941 0.8 50 (28) NA 1189 0.3 NA 1693 0.57 51 (28) 1842 0.70 47 (26) 1941 0.8 44 (25) 1027 0.25 NA 1189 0.3 NA 1655 0.59 58 (32) 1802 0.71 53 (30) 1888 0.81 51 (28) NA 1139 0.32 NA 1655 0.59 52 (29) 1802 0.71 48 (27) 1888 0.81 46 (25) 974 0.26 NA 1139 0.32 NA 1616 0.60 60 (33) 1760 0.73 55 (30) 1860 0.81 52 (29) NA 1072 0.33 NA 1616 0.60 53 (30) 1760 0.73 49 (27) 1860 0.81 46 (26) 942 0.27 NA 1072 0.33 NA EXTERNAL STATIC PRESSURE (IN. W.C.) 0.3 0.4 0.5 0.6 0.7 0.8 1177 1121 1066 1027 974 942 0.21 0.23 0.24 0.25 0.26 0.27 1341 0.26 0.2 1229 0.20 0.1 1271 0.19 DRY COIL AIR DELIVERY -- HORIZONTAL AND DOWNFLOW DISCHARGE - 48VG--A 460 VAC MODELS 48VG -- A 1570 0.64 61 (34) 1719 0.74 56 (31) 1785 0.79 54 (30) NA 1027 0.34 NA 1570 0.64 55 (31) 1719 0.74 50 (28) 1785 0.79 48 (27) 887 0.28 NA 1027 0.34 NA 0.9 887 0.28 1532 0.63 63 (35) 1643 0.72 59 (33) 1751 0.75 55 (31) NA 982 0.35 NA 1532 0.63 56 (31) 1643 0.72 52 (29) 1751 0.75 49 (27) 839 0.29 NA 982 0.35 NA 1 839 0.29 47 600 0.03 700 0.04 800 0.04 900 0.05 0.05 0.06 -- -- 0.04 700 1000 0.06 0.06 0.06 0.05 -- -- 0.05 800 1500-2200 CFM 16x24x1+18x24x1 (406x610x25+457x356x25) 600-1400 CFM 12x20x1+12x20x1 (305x508x25+305x508x25) 1200-1800 CFM 16x24x1+14x24x1 (406x610x25+356x610x25) FILTER SIZE IN. (MM) -- -- 3.0 3.5, 4.0 5.0 -- 600 2.0, 2.5, COOLING TONS -- -- -- 700 -- -- 0.08 800 Economizer with 1--in. Filter Pressure Drop (IN. W.C.) UNIT SIZE 24 30 36 42 48 60 -- -- 3.0 3.5, 4.0 5.0 0.03 600 2.0, 2.5, COOLING TONS Wet Coil Pressure Drop (IN. W.C.) 1500-2200 CFM 16x24x1+18x24x1 (406x610x25+457x356x25) 600-1400 CFM 12x20x1+12x20x1 (305x508x25+305x508x25) 1200-1800 CFM 16x24x1+14x24x1 (406x610x25+356x610x25) FILTER SIZE IN. (MM) Filter Pressure Drop Table (IN. W.C.) -- -- 0.09 -- -- 0.10 -- 0.05 0.07 1100 -- 0.09 0.11 1100 0.08 0.10 0.06 0.04 0.07 0.09 0.05 900 1200 1000 -- 0.04 0.06 1000 1100 -- -- 0.06 900 -- 0.07 0.08 -- 0.08 0.08 -- 0.09 0.11 1200 0.11 0.11 0.07 0.06 0.08 0.10 0.06 0.09 0.10 0.07 0.09 0.11 0.01 1700 0.06 0.09 -- 1600 -- 0.10 0.13 -- 0.12 0.14 0.15 0.13 -- 0.18 0.17 -- 1700 0.11 0.12 0.08 1800 0.08 0.10 -- 1700 48VG -- A 0.17 0.15 -- STANDARD CFM (SCFM) 1300 1400 1500 1600 0.14 0.08 0.09 1600 0.04 0.09 -- STANDARD CFM (SCFM) 1300 1400 1500 STANDARD CFM (SCFM) 1300 1400 1500 -- 0.06 0.07 1200 0.20 0.17 -- 1800 0.10 0.11 -- 1800 0.21 0.19 -- 1900 0.13 0.09 1900 0.11 0.12 -- 1900 0.22 0.21 -- 2000 0.14 0.10 2000 0.13 0.12 -- 2000 0.23 -- -- 2100 0.12 2100 0.14 -- -- 2100 0.23 -- -- 2200 0.13 2200 0.15 -- -- 2200 TYPICAL PIPING AND WIRING ROOF-MOUNTING CURB ROOF RETURN-AIR FLEXIBLE DUCT 48VG -- A SUPPLY-AIR FLEXIBLE DUCT CEILING CONCENTRIC DIFFUSER BOX (FIELD-SUPPLIED) A09233 INDOOR THERMOSTAT RETURN AIR FROM POWER SOURCE TOP COVER DISCONNECT PER NEC* FROM GAS LINE *NEC - NATIONAL ELECTRICAL CODE A09234 48 Condensate trap — A 2--in. (50.8 mm) condensate trap must be field supplied. Ductwork — Secure downflow discharge ductwork to roof curb. For horizontal discharge applications, attach ductwork to unit with flanges. To convert a unit to downflow discharge — Units are equipped with factory--installed inserts in the down--flow openings. Removal of the inserts is similar to removing an electrical knock--out. Use the duct cover to seal the horizontal discharge openings in the unit. Units installed in horizontal discharge orientation do not require duct covers. Airflow — Units are draw--thru in the cooling mode and blow--thru in the heating mode. Maximum cooling airflow — To minimize the possibility of condensate blow--off from the evaporator, airflow through the units should not exceed 450 cfm per ton. Minimum cooling airflow — Minimum cooling airflow is 350 cfm per ton. Minimum ambient cooling operation temperature — All standard units have a minimum ambient operating temperature of 40_F (4_C). With accessory low ambient temperature kit, units can operate at temperatures down to 0_F (--17_C). Minimum temperature — Air entering the heat exchanger in heating mode must be a minimum of 55_F (13_C) continuous and a maximum of 80_F (27_C) continuous. 48VG -- A APPLICATION DATA 49 ELECTRICAL DATA 48VG -- A UNIT NOMINAL VOLTAGE RANGE COMPRESSOR OFM IFM IDM MIN MAX RLA LRA FLA FLA FLA POWER SUPPLY MCA MOCP 48VG(--- ,N)A2404030 48VG(--- ,N)A2406030 208/230-1-60 197 253 11.7 58.3 0.7 4.1 .21 19.4 30 48VG(--- ,N)A3004030 48VG(--- ,N)A3006030 208/230-1-60 197 253 13.1 73.0 1.2 4.1 .21 21.7 30 48VG(--- ,N)A3004050 48VG(--- ,N)A3006050 208/230-3-60 197 253 8.7 58.0 1.2 4.1 .21 16.2 20 48VG(--- ,N)A3606030 48VG(--- ,N)A3609030 208/230-1-60 197 253 15.3 83.0 1.2 6.0 .21 26.3 40 48VG(--- ,N)A3606050 48VG(--- ,N)A3609050 208/230-3-60 197 253 11.6 73.0 1.2 6.0 .21 21.7 30 460-3-60 414 506 5.7 38.0 0.53 3.2 10.8 15 48VG(--- ,N)A4206030 48VG(--- ,N)A4209030 208/230-1-60 197 253 17.9 96.0 1.2 6.0 .21 29.6 45 48VG(--- ,N)A4206050 48VG(--- ,N)A4209050 208/230-3-60 197 253 14.2 88.0 1.2 6.0 .21 25.0 35 460-3-60 414 506 6.2 44.0 0.53 3.2 11.5 15 35.3 50 26.3 40 12.5 15 44.8 60 29.1 40 14.0 20 48VG(--- ,N)A3606060 48VG(--- ,N)A3609060 48VG(--- ,N)A4206060 48VG(--- ,N)A4209060 48VG(--- ,N)A4809030 48VG(--- ,N)A4811530 .65 .33 .65 .33 .21 208/230-1-60 197 253 21.2 104.0 1.2 7.6 .50 48VG(--- ,N)A4813030 .50 48VG(--- ,N)A4809050 .21 48VG(--- ,N)A4811550 208/230-3-60 197 253 14.0 83.1 1.2 7.6 .50 48VG(--- ,N)A4813050 .50 48VG(--- ,N)A4809060 .33 48VG(--- ,N)A4811560 460-3-60 414 506 6.4 41.0 0.53 4.0 .65 48VG(--- ,N)A4813060 .30 48VG(--- ,N)A6009030 .21 48VG(--- ,N)A6011530 208/230-1-60 197 253 28.8 152.9 1.2 7.6 .50 48VG(--- ,N)A6013030 .50 48VG(--- ,N)A6009050 .21 48VG(--- ,N)A6011550 208/230-3-60 197 253 16.2 110.0 1.2 7.6 .50 48VG(--- ,N)A6013050 .50 48VG(--- ,N)A6009060 .33 48VG(--- ,N)A6011560 460-3-60 414 506 7.6 52.0 48VG(--- ,N)A6013060 .053 4.0 .65 .30 50 ELECTRICAL DATA (CONT) LEGEND 48VG -- A FLA - Full Load Amps IDM - Inducer Motor IFM - Indoor Fan Motor LRA -Locked Rotor Amps MCA - Minimum Circuit Amps MOCP - Maximum Over Current Protection OFM - Outdoor Fan Motor RLA - Rated Load Amps 51 48VG -- A CONNECTION WIRING SCHEMATIC GAS INPUTS 40, 60 ,90 KBTU/HR 208/230--1--60 A13018 52 48VG -- A LADDER WIRING SCHEMATIC GAS INPUTS 40, 60 90 KBTU/HR 208/230--1--60 A13019 53 48VG -- A CONNECTION WIRING SCHEMATIC GAS INPUTS 115, 130 KBTU/HR 208/230--1--60 A13020 54 48VG -- A LADDER WIRING SCHEMATIC GAS INPUTS 115, 130 KBTU/HR 208/230--1--60 A13021 55 48VG -- A CONNECTION WIRING SCHEMATIC GAS INPUTS 40, 60, 90 KBTU/HR 208/230--3--60 A13022 56 48VG -- A LADDER WIRING SCHEMATIC GAS INPUTS 40, 60, 90 KBTU/HR 208/230--3--60 A13023 57 48VG -- A CONNECTION WIRING SCHEMATIC GAS INPUTS 115, 130 208/230--3--60 A13024 58 48VG -- A LADDER WIRING SCHEMATIC GAS INPUTS 115, 130 208/230--3--60 A13025 59 48VG -- A CONNECTION WIRING SCHEMATIC 460--3--60 A13026 60 48VG -- A LADDER WIRING DIAGRAM 460--3--60 A13027 61 CONTROLS 48VG -- A Operating sequence 208/230 VAC Models: On a call for low stage heating, terminal W1 on the thermostat is energized. On a call for high stage heating both terminals W1 and W2 are energized. Regardless of the stage of the heating call, the induced--draft motor is turned on to high speed for a 15 sec pre--purge time. After the pre--purge, when the pressure switch senses that sufficient combustion air is being moved by the induced--draft motor, the ignition sequence begins. The IGC will energize the sparker and the low stage gas valve solenoid. Upon sensing flame, the IGC will check the heating call. If W2 is not energized, the IGC will drop the induced--draft motor to low speed and maintain the gas valve on low stage. If W2 is energized, the IGC will maintain the induced--draft motor on high speed and energize the high stage gas valve solenoid. Thirty sec after flame is sensed the IGC will turn on the evaporator fan motor. If W2 is not energized, the evaporator fan motor will run on low heat speed. If W2 is energized, the evaporator fan motor will run on high heat speed. After the call for heat is satisfied, the IGC will run the evaporator fan motor an additional field--selectable time of 90, 120, 150, or 180 sec before shutting the evaporator fan motor off. 460 VAC Models: On a call for heating, terminal W of the thermostat is energized, starting the induced--draft motor. When the pressure switch senses that the induced--draft motor is moving sufficient combustion air, the ignition sequence begins. This function is performed by the integrated gas unit controller (IGC). The indoor (evaporator)--fan motor is energized 45 sec after flame is established. When the thermostat is satisfied and W is de--energized, the burners stop firing and the indoor (evaporator) fan motor shuts off after a 45--sec time--off delay. Please note that the IGC has the capability to automatically reduce the indoor fan motor on delay and increase the indoor fan motor off delay in the event of high duct static and/or partially--clogged filter. Cooling — When the system thermostat calls for cooling, 24 V is supplied to the “Y1/Y” and “G” terminals of the thermostat. This completes the circuit to the contactor coil (C) and indoor (evaporator) fan relay (IFR). The normally open contacts of energized C close and complete the circuit through compressor motor (COMP) to outdoor (condenser) fan motor (OFM). Both motors start instantly. The set of normally open contacts of energized IFR close and complete the circuit through IFM. The IFM starts instantly. On the loss of the thermostat call for cooling, 24 V is removed from both the “Y1/Y” and “G” terminals (provided the fan switch is in the “AUTO” position) de--energizing the compressor contactor and opening the contacts supplying power to compressor/OFM. After a 60--second delay, the IFM shuts off. If the thermostat fan selector switch is in the “ON” position, the IFM will run continuously. NOTE: On units with a Time Guard II device: Once the compressor has started and then stopped, it cannot be restarted again until 5 minutes have elapsed. 62 Packaged Gas Heating/Electric Cooling Units Constant Volume Application HVAC Guide Specifications Size Range: 2 to 5 Tons, Nominal Cooling 40,000 to 130,000 Btuh, Nominal Heating Input Model Number: 48VG--A Part 1 — General SYSTEM DESCRIPTION Outdoor rooftop or ground mounted air conditioner and gas furnace system utilizing a two--stage scroll compressor for cooling duty. Unit shall discharge supply air vertically or horizontally as shown on contract drawings. Outdoor fan/coil section shall have a draw--thru design with vertical discharge for minimum sound levels. QUALITY ASSURANCE A. Unit shall be rated in accordance with AHRI Standards 210/240 and 270. B. Unit shall be designed in accordance with UL Standard 1995 and ANSI Z 21.47. C. Unit shall be manufactured in a facility registered to ISO 9001 manufacturing quality standard. D. Unit shall be UL listed and c--UL certified as a total package for safety requirements. E. Roof curb shall be designed to conform to NRCA Standards. F. Insulation and adhesives shall meet NFPA 90.1 requirements for flame spread and smoke generation. G. Cabinet insulation shall meet ASHRAE Standard 62.2. DELIVERY, STORAGE AND HANDLING Unit shall be stored and handled per manufacturer’s recommendations. Part 2 — Products EQUIPMENT A. General: Factory--assembled, single--piece, heating and cooling unit. Contained within the enclosure shall be all factory wiring, piping, controls, refrigerant charge with R--410A refrigerant, and special features required prior to field start--up. B. Unit Cabinet: 1. Unit cabinet shall be constructed of phosphated, zinc--coated, pre--painted steel capable of with--standing 500 hours in salt spray. 2. Normal service shall be through 3 removable cabinet panels. 3. The unit shall be constructed on a rust proof unit base that has an externally trapped, integrated sloped drain. 4. Evaporator fan compartment top surface shall be insulated with a minimum 1/2--in. (12.7 mm) thick, flexible fiberglass insulation, coated on the air side and retained by adhesive and mechanical means. The evaporator wall sections will be insulated with a minimum semi--rigid foil-faced board capable of being wiped clean. Aluminum foil-faced fiberglass insulation shall be used in the entire indoor air cavity section. 5. Unit shall have a field--supplied condensate trap. C. Fans: 1. The evaporator fan shall be a multi--speed, direct--drive, as shown on equipment drawings. 2. Fan wheel shall be made from steel, be double--inlet type with forward curved blades with corrosion resistant finish. Fan wheel shall be dynamically balanced. D. E. F. G. H. I. J. K. L. M. 63 3. Condenser fan shall be direct drive propeller type with aluminum blades riveted to corrosion resistant steel spiders, be dynamically balanced, and discharge air vertically. Compressor: 1. Fully hermetic compressors with factory--installed vibration isolation. 2. Two--stage scroll compressors shall be standard on all units. Coils: Evaporator and condenser coils shall have aluminum plate fins mechanically bonded to seamless copper tubes with all joints brazed. Tube sheet openings shall be belled to prevent tube wear. Heating Section: 1. Induced--draft combustion type with energy saving direct spark ignition system and redundant main gas valve. 2. Induced--draft motors shall provide adequate airflow for combustion. 3. The heat exchangers shall be constructed of aluminized steel for corrosion resistance. 4. Burners shall be of the in--shot type constructed of aluminum coated steel. 5. All gas piping and electric power shall enter the unit cabinet at a single location. Refrigerant Components: Refrigerant expansion device shall be of the TXV (thermostatic expansion valve) type. Filters: Filter section shall consist of field--installed, throwaway, 1--in. (25 mm) thick fiberglass filters of commercially available sizes. Controls and Safeties: 1. Unit controls shall be complete with a self--contained low voltage control circuit. 2. Compressors shall incorporate a solid--state compressor protector that provides reset capability. Operating Characteristics: 1. Unit shall be capable of starting and running at 125_F (51_C) ambient outdoor temperature per maximum load criteria of AHRI Standard 210. 2. Compressor with standard controls shall be capable of operation down to 40_F (4_C) ambient outdoor temperature. 3. Units shall be provided with fan time delay to prevent cold air delivery before the heat exchanger warms up. 4. Unit shall be provided with 90--second fan time delay after the thermostat is satisfied. Electrical Requirements: All unit power wiring shall enter the unit cabinet at a single location. Motors: 1. Compressor motors shall be of the refrigerant--cooled type with line--break thermal and current overload protection. 2. All fan motors shall have permanently lubricated bearings, and inherent, automatic reset, thermal overload protection. 3. Condenser fan motor shall be totally enclosed. 4. Evaporator Fan Motor to be multi--speed ECM blower motor. Compressor Protection: Solid--state control shall protect compressor by preventing “short cycling.” 48VG -- A GUIDE SPECIFICATIONS 48VG -- A GUIDE SPECIFICATIONS (CONT) N. Low NOx: Shall provide NOx reduction to values below 40 nanograms/ joule to meet California’s and other localities’ emission requirements as shipped from factory. O. Special Option/Kits Available: 1. Coil Options Base unit with tin plated indoor coil hairpins available as a factory installed option. 2. Compressor Start Kit (single phase units only): Shall provide additional starting torque for single--phase compressors. 3. Corporate Thermostat: To provide for one--stage heating and cooling in addition manual or automatic changeover and indoor fan control. 4. Crankcase Heater Kit: Shall provide anti--floodback protection for low--load cooling applications. 5. Economizer for two--stage operation: (Horizontal and Vertical with Jade Honeywell W7220 controller, Honeywell communicating actuator, and dry bulb sensor. (Contact MicroMetl Customer Service at 1--800--662--4822 to order.) NOTE: The enhanced dehumidification feature on high stage cooling does not support use of an economizer. a. Economizer controls capable of providing free cooling using outside air. b. Equipped with low leakage dampers not to exceed 3% leakage, at 1.0 IN. W.C. pressure differential. c. Spring return motor shuts off outdoor damper on power failure. 6. Filter Rack Option or Kit: Shall provide filter mounting for downflow applications. Offered as an accessory or as a factory installed option. Copyright 2013 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 7. Flat Roof Curb Kit: Curbs shall have seal strip and a wood nailer for flashing and shall be installed per manufacturer’s instructions. 8. Flue Discharge Deflector Kit Directs flue gas exhaust; 90 degrees upward from current discharge. 9. Heat Exchanger Option Stainless Steel Heat Exchanger available as a factory installed option. 10. High Altitude Propane Conversion Kit: Shall consist of all required hardware to convert to propane gas heat operation at 2001 to 6000 ft (611 to 1829 m) above sea level. 11. Low Ambient Package Kit: Shall consist of a solid--state control and condenser coil temperature sensor for controlling condenser--fan motor operation, which shall allow unit to operate down to 0_F (--18_C) outdoor ambient temperature when properly installed. 12. Manual Outdoor Air Damper Kit: Package shall consist of damper, birdscreen, and rainhood which can be preset to admit outdoor air for year--round ventilation. 13. Natural--to--Propane Conversion Kit: Shall be complete with all required hardware to convert to propane gas operation at 10.0 IN. W.C. manifold pressure. 14. Propane--to--Natural Conversion Kit Shall be complete with all hardware to convert to natural gas at standard altitude (0 to 2000 ft [0 to 610 m] above sea level). 15. Square--To--Round Duct Transitions Kit (24--48 models): Shall have the ability to convert the supply and return openings from rectangular to round. Edition Date: 03/13 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 64 Catalog No: 48VG ---01PD Replaces: NEW
© Copyright 2024 ExpyDoc