turnberry cnl sensor

Project:
Type:
Ordering # :
Comments:
ARCHITECTURAL OUTDOOR
TURNBERRY CNL
FEATURESPECS
• Die-Formed Steel Housing w/ Textured White Powder Coat Finish
• Aluminum Trim w/ Textured White Powder Coat Finish
• Die-Cast Aluminum End Caps w/ Recessed Screw Holes & Textured White
Powder Coat Finish
• High Impact White Acrylic Diffuser (50% DR Acrylic)
• Mounts Directly to Wall or Ceiling w/ Four Wall Anchors (Not Included)
• Lens Can be Removed and Replaced Without Sliding Length of Fixture
• Maintenance-Friendly For Tight Corners
• Integral EM Battery Available
(38” & 50” Fixtures Only)
• CSA Listed Damp Location For Wall
or Ceiling Mount
Textured Bronze Finish Shown
LINEAR FLUORESCENT
ORDERING INFORMATION
Example : (TRN - CNL - 48232E - 120E - SM)
PRODUCT
SOURCE/WATTAGE
Textured White is Standard Finish
VOLTAGE
DIFFUSER
Turnberry
CNL 26”
120E - 120V Electronic
TRN-CNL-24117E - (1) 17W T8
277E - 277V Electronic
TRN-CNL-24217E - (2) 17W T8
347E - 347V Electronic
TRN-CNL-24214E - (2) 14W T5
TRN-CNL-24224E - HO* - (2) 24W T5
Turnberry
CNL 38”
TRN-CNL-36125E - (1) 25W T8
TRN-CNL-36225E - (2) 25W T8
TRN-CNL-36221E - (2) 21W T5
TRN-CNL-36239E - HO* - (2) 39W T5
Turnberry
CNL 50”
TRN-CNL-48132E - (1) 32W T8
TRN-CNL-48232E - (2) 32W T8
TRN-CNL-48228E - (2) 28W T5
TRN-CNL-48254E - HO* - (2) 54W T5
Not Applicable
OPTIONS
RAL Colors or Custom
Match - Consult Factory
*HO - High Output
R E P L A C E M E N T PA R T S
PA R T N O .
24” White Acrylic Diffuser
36” White Acrylic Diffuser
48” White Acrylic Diffuser
3025960
3026060
3026160
FINISH
SM - Matte Silver
TB - Textured Black
AC - Antique Copper
AS - Antique Silver
BT - Bronze Mist
CP - Copper
KC - Kenworth Chrome
SN - Sand
SW - Swedish Steel
BZ - Textured Bronze
TW - Textured White
We reserve the right to revise the design or components of any product due to
parts availability or change in UL standards, without assuming any obligation or
liability to modify any products previously manufactured, and without notice.
MS - Motion Sensor
- Wattstopper FS-505 (See Turnberry
CNL Sensor Cutsheet For Specs)
EB - Integral Emergency Battery**
(38” & 50” Fixtures Only)
(120V / 277V Only)
TP - Tamper Resistant Screws
F - Fused
W2L - Wire 2 Lamps to Integral
Emergency Battery
(120V / 277V - T8 Lamping Only)
DIM - Dimming Ballast
(120V / 277V - T8 Lamping Only)
MSP - Program Start Ballast
(Recommended for Motion Sensor) ***
NOTES
**Emergency Battery Options
Initial light output in Emergency mode will last for a minimum of 90 minutes.
1 lamp wired unless ordered otherwise. The following are suitable for indoor
and damp locations. Please refer to Bodine’s specification sheet
EB:
Bodine’s B50LP (T8 Electronic) - Temperature Rating (Ambient) 32° F - 131° F
Bodine’s B550LP (T5 Electronic) - Temperature Rating (Ambient) 32° F - 122° F
*** For Electronic Wattage Fixtures Being Used in Conjunction With an
Occupancy Sensor (Either Provided by us, or Your Own System), a Program
Start Ballast is Recommended in Order to Maximize Lamp Life.
33 Donald Drive Fairfield, OH 45014
ph:(513)858-6004
fax:(513)858-6038
email:[email protected]
web:teronlight.com
Project:
Type:
Ordering # :
Comments:
ARCHITECTURAL OUTDOOR
FEATURES
TURNBERRY CNL
• Die-Formed Steel Housing w/ Textured White Powder Coat Finish
• Aluminum Trim w/ Textured White Powder Coat Finish
• Die-Cast Aluminum End Caps w/ Recessed Screw Holes & Textured White
Powder Coat Finish
• High Impact White Acrylic Diffuser (50% DR Acrylic)
• Mounts Directly to Wall or Ceiling w/ Four Wall Anchors (Not Included)
• Lens Can be Removed and Replaced Without Sliding Length of Fixture
• Maintenance-Friendly For Tight Corners
• Integral EM Battery Available
(38” & 50” Fixtures Only)
• CSA Listed Damp Location For Wall
or Ceiling Mount
Matte Silver Finish Shown
LINEAR FLUORESCENT
ORDERING INFORMATION
Example : (TRN36221E / 114E - 120E - SN - MSI)
PRODUCT
SOURCE/WATTAGE
Turnberry
CNL 26”
TRN-CNL-24317E - (3) 17W T8
TRN-CNL-24314E - (3) 14W T5
Turnberry
CNL 38”
TRN-CNL-36225E/117E - (2) 25W T8 & (1) 17W T8
TRN-CNL-36325E - (3) 25W T8
TRN-CNL-36221E/114E - (2) 21W T5 & (1) 14W T5
TRN-CNL-36221E/124E - (2) 21W T5 & (1) 24W T5 HO
TRN-CNL-36239E/114E - (2) 39W T5 HO & (1) 14W T5
TRN-CNL-36239E/124E - HO - (2) 39W T5 HO & (1) 24W T5 HO
Turnberry
CNL 50”
TRN-CNL-48232E/117E - (2) 32W T8 & (1) 17W T8
TRN-CNL-48332E - (3) 32W T8
TRN-CNL-36228E/114E - (2) 28W T5 & (1) 14W T5
TRN-CNL-48228E/124E - HO - (2) 28W T5 & (1) 24W T5 HO
TRN-CNL-48254E/114E - (2) 54W T5 HO & (1) 14W T5
TRN-CNL-48254E/124E - HO - (2) 54W T5 HO & (1) 24W T5 HO
Textured White is Standard Finish
VOLTAGE
DIFFUSER
PA R T N O .
26” White Acrylic Diffuser
38” White Acrylic Diffuser
50” White Acrylic Diffuser
3025960
3026060
3026160
We reserve the right to revise the design or components of any product due to
parts availability or change in UL standards, without assuming any obligation or
liability to modify any products previously manufactured, and without notice.
OPTIONS
120E - Electronic Not Applicable SM - Matte Silver
277E - Electronic
TB - Textured Black
AC - Antique Copper
120E - Electronic
AS - Antique Silver
277E - Electronic
BT - Bronze Mist
CP - Copper
SN - Sand
SW - Swedish Steel
BZ - Textured Bronze
TW - Textured White
120E - Electronic
277E - Electronic
RAL Colors or
Custom Match
- Consult Factory
(HO* - High Output)
R E P L A C E M E N T PA R T S
FINISH
F - Fused
EBW - Integral Emergency Battery
(3’ & 4’ Only) (See Below)
MSE - Watt-Stopper FS505
External Motion Sensor
(Will Add 1 11/16” to Fixture Depth)
MSI - Steinel HFLUM2-120
Internal Motion Sensor (120V Only)
-MSI For Use With The Following:
- (3) 2’ Lamps
- (2) 3’ or 4’ Lamps w/ (1) 2’ Lamp
TP -Tamper Resistant Screws
W2L - Wire 2 Lamps to Integral
Emergency Battery
(T8 Lamping Only)
MSP - Program Start Ballast
(Recommended for Motion Sensor) ***
NOTES
Emergency Battery Options
Initial light output in Emergency mode will last for a minimum of 90 minutes.
1 lamp wired unless ordered otherwise. The following are suitable for indoor
and damp locations. Please refer to Bodine’s specification sheet.
EBW:
Bodine’s B50LP (T8 Electronic) - Temperature Rating (Ambient) 32° F - 122° F
Bodine’s LP550 (T5 Electronic) - Temperature Rating (Ambient) 32° F - 122°
*** For Electronic Wattage Fixtures Being Used in Conjunction With an
Occupancy Sensor (Either Provided by us, or Your Own System), a Program
Start Ballast is Recommended in Order to Maximize Lamp Life.
33 Donald Drive Fairfield, OH 45014
ph:(513)858-6004
fax:(513)858-6038
email:[email protected]
web:teronlight.com
Project:
Type:
Ordering # :
Comments:
ARCHITECTURAL OUTDOOR
MOTION SENSOR SPECS
FEATURES
TURNBERRY CNL - MOTION SENSOR
• Die-Formed Steel Housing w/ Textured White
Powder Coat Finish
• High Impact White Acrylic Diffuser (50% DR Acrylic)
• Aluminum Reflector Plate w/ Hi-Reflectance White
Powder Coat Finish
• Die-Cast Aluminum End Caps w/ Recessed
Screw Holes
• Mounts Directly to Wall or Ceiling w/ Four Wall
Anchors (Not Included)
• CSA Listed Damp Location
• Integral EM Battery Available
• Maintenance-Friendly For Tight Corners
• Lens Can be Removed and Replaced Without
Sliding Length of Fixture
Textured Bronze Finish Shown
• Optional Bracket Required for Wattstopper
FS-505 Motion Sensor
• Hi-Frequency Sensitive Ultrasonic
• LED Status Indicator Light
• Lamp Conditioning Circuit
• Fail-Safe Sensor Switches Light Level to
100% if Sensor is Physically Damaged
• 5-Minute Walk-Test Feature, Easy-Set
• Time / Sensitivity Controls
Please Note: TLI is Not Responsible For
Misapplication of Fixture With Motion Sensors
Consult Pg. 3 For Specific Application &
Coverage Patterns. The FS-505 Motion
Sensor is For Wall Mount Usage Only.
ORDERING INFORMATION
Example : (TRN - CNL - 48232E - 120E - SDIM50 - TB - MS)
PRODUCT
SOURCE/WATTAGE
VOLTAGE
Turnberry 26”
TRN-CNL-24217E - (2) 17W T8**
120E - 120V Electronic
277E - 277V Electronic
TRN-CNL-24214E - (2) 14W T5
TRN-CNL-24224E - HO* - (2) 24W T5
Turnberry 38”
TRN-CNL-36225E - (2) 25W T8 **
TRN-CNL-36221E - (2) 21W T5
TRN-CNL-36239E-HO* - (2) 39W T5
Turnberry 50”
TRN-CNL-48232E - (2) 32W T8**
TRN-CNL-48228E - (2) 28W T5**
TRN-CNL-48254E - HO* - (2) 54W T5
Textured White is Standard Finish
DIMMING CONFIG
SDIM10** - Lamps Set at 10% Output
w/ No Occupancy & 100% Outout
w/ Motion Sensor Occupancy Read
(See Pg. 3)
SDIM40** - Lamps Set at 40% Output
w/ No Occupancy & 100% Outout
w/ Motion Sensor Occupancy Read
(See Pg. 3)
SDIM50** - Lamps Set at 50% Output
w/ No Occupancy & 100% Outout
w/ Motion Sensor Occupancy Read
(See Pg. 3)
*HO - High Output
** Wattages Available For
“SDIM” Option
FINISH
SM - Matte Silver
TB - Textured Black
AC - Antique Copper
AS - Antique Silver
BT - Bronze Mist
CP - Copper
KC - Kenworth Chrome
SN - Sand
SW - Swedish Steel
BZ - Textured Bronze
TW - Textured White
RAL Colors or
Custom Match Consult Factory
OPTIONS
MS - Motion Sensor
- Wattstopper FS-505 (See Pg.2)
(Requires Back Plate, Which Will
Add 5/16” to Fixture Length &
1 11/16” to Fixture Depth)
EB - Integral Emergency Battery**
(For Use With MS2B Only)
(Consult Factory For Application
Specs / Battery Option)
TP - Tamper Resistant Screws
W2L - Wire 2 Lamps to Integral
Emergency Battery
(T8 Lamping Only)
MSP - Program Start Ballast
(Standard w/ Motion Sensor) ***
MS2B - 1 Lamp at 100% Constant
Output, and 1 Lamp Connected to
Motion Sensor (Requires 2 Ballasts)
Please Refer to Page 2 for Step-Dim
& MS2B Specifications, Options, and
Restrictions
*** For Electronic Wattage Fixtures Being Used in Conjunction With an
Occupancy Sensor (Either Provided by us, or Your Own System), a Program
Start Ballast is Recommended in Order to Maximize Lamp Life.
33 Donald Drive Fairfield, OH 45014
ph:(513)858-6004
fax:(513)858-6038
email:[email protected]
web:teronlight.com
Project:
Type:
Ordering # :
Comments:
ARCHITECTURAL VANITY
TURNBERRY CNL SENSOR
DIMMING APPLICATIONS & RESTRICTIONS
• Step-Dimming is available at 10% and 40% for 25W and 32W T8 linear lamps
- Emergency Battery is not available for use with the 10% and 40% Step-Dim option
- Ballast used is the Robertson brand #PSL232T8MV3D
• Step-Dimming is available at 50% for 17W, 25W, and 32W T8 Linear Lamps
- Emergency Battery is available for use with the 50% Step-Dim option
- Ballast used is the Universal brand #B232PUS50-A
• Step-Dimming is available at 50% for 28W T5 Linear Lamps
- Emergency Battery is available for use with the 50% Step-Dim option
- Ballast used is the Philips Advance brand #IOP-2S28-95-SC-SD
• All 3 ballasts meet California’s Title 24 requirement by reducing power
by 50% or more
MOTION SENSOR WITH 2 BALLASTS “MS2B” APPLICATIONS & RESTRICTIONS
• The “MS2B” option is intended to have one lamp providing 100% constant light output, while the other lamp is connected to the
Motion Sensor. Two ballasts are required with this option
• Emergency Battery is available in conjuction with the “MS2B” option for 38” and 50” fixtures
• Emergency battery is not available for 26” fixtures in conjunction with the “MS2B” option
due to fixture space restrictions
R E P L A C E M E N T PA R T S
PA R T N O .
26” White Acrylic Diffuser
38” White Acrylic Diffuser
50” White Acrylic Diffuser
3025960
3026060
3026160
We reserve the right to revise the design or components of any product due to
parts availability or change in UL standards, without assuming any obligation or
liability to modify any products previously manufactured, and without notice.
NOTES
Emergency Battery Options
Initial light output in Emergency mode will last for a minimum of 90 minutes.
1 lamp wired unless ordered otherwise. The following are suitable for indoor
and damp locations. Please refer to Bodine’s specification sheet
EB:
Bodine’s B50LP (T8 Electronic) - Temperature Rating (Ambient) 32° F - 131° F
Bodine’s LP550 (T5 Electronic) - Temperature Rating (Ambient) 32° F - 122°F
*** For Electronic Wattage Fixtures Being Used in Conjunction With an
Occupancy Sensor (Either Provided by us, or Your Own System), a Program
Start Ballast is Recommended in Order to Maximize Lamp Life.
33 Donald Drive Fairfield, OH 45014
ph:(513)858-6004
fax:(513)858-6038
email:[email protected]
web:teronlight.com
HFLUM2-WR
Fixture Integrated Sensor Module
Project Name:
Location:
HF LUM2-WR Specifications
Item No.
Voltage
Load Rating
Transmitter Power
Power Consumption
65122
120/230/277 VAC, 50/60 Hz
0-800 watts @ 120 VAC, 50/60 Hz incandescent, magnetic or electronic ballasts - 1/4 HP
0-1200 watts @ 230/277 VAC, 50/60 Hz magnetic or
electronic ballasts
0-650 watts @ 120/230/277 VAC, 50/60 Hz LED
1 mW
< 0.5 W
Time Delay Setting
30 seconds to 30 minutes
Light Level Setting
0.2-200 footcandles
2-2000 lux
HF System
Coverage
Environment
5.8 GHz
360° adjustable 3.3 to 26 ft reach (1 to 8 m)
requires enclosure
temperature -4° F - 185° F, -20° C - 85° C
Dimensions 4.2 x 1.7 x 1.8 in
(LxWxD) 107 x 42 x 44.5 mm
Warranty
Certifications
The HFLUM2-WR is a line voltage occupancy sensor module
that installs in a fixture, adding energy saving lighting control
in each fixture location. The HFLUM2-WR uses STEINEL’s High Frequency (HF)
technology to turn lights on and off based on occupancy.
It works by emitting high frequency electromagnetic waves
(5.8 GHz) into the controlled area. Movement in the area
causes a change in the waves’ echo, resulting in occupancy detection. The sensor can detect motion through many
materials including glass and the lens of a fixture, enabling
the sensor to be hidden from view.
5 years
C-UL-US Listed, RoHS Compliant,
Contains: FCC ID - W8J-SIR13, IC - 8529A-SIR13
Key Features:
•
•
•
•
•
•
•
360° coverage; reach is adjustable from 3.3 to 26 ft
High frequency technology emits 5.8 GHz electromagnetic
waves
Built-in surge protection with auto-reset
Lamp seasoning feature provides a simple and convenient 4
day burn in as recommended by lamp manufacturers
Adjustable time delay and light level settings
Light level feature allows lighting to remain off during daylight,
regardless of occupancy (hold off)
Wiring is streamlined with three terminals
Applications
Mounted in either a ceiling or wall lighting fixture, the sensor
module is suited to a wide variety of interior spaces including
offices, conference rooms and damp or wet locations when
mounted inside sealed and gasketed fluorescent IP65 type
fixtures.
Line Voltage
High Frequency Technology
360˚ of Coverage
Fixture Integrated
0.2 - 200 fc
www.steinel.net
HF LUM2-WR
Fixture Integrated Sensor Module
Controls
Photocell
Sensitivity
Sensor dome
Time delay
antenna
Light Level
Wire
terminations
Mounting
tabs
Mounting
Coverage
3.3 - 13 ft
1-4m
44.5 mm
1.75”
Typical mounting
height is 8 to 10 ft
Mounting screw
holes are 3.8 inches
(97 mm) apart
107 mm
4.2”
97 mm
3.8”
3.3 - 26 ft
1-8m
Wiring
Coverage Adjustments
Sensitivity:
Adjusts coverage reach
from approximately 3.3
feet to 26 feet
42 mm
1.65”
3.3 - 16.4 ft
ca. 1 - 5 m
Time delay:
30 seconds to
30 minutes
Light level:
.2 (night) to 200
(day) footcandles
NEUTRAL
HOT
LOAD
www.steinel.net
(800) 852-4343
9051 Lyndale Avenue South, Bloomington, MN 55420
M-04105-1