type coaxial valve VSV-F 80

www.co-ax.com
data sheet
E5.14-11/2009
coaxial valve
type VSV-F 80
5-VSV-F 80
valve type with pilot valve
2/2 way valve
pressure range
orifice
connection
function
externally controlled
PN 0-40 bar
DN 80 mm
flange
valve
normally closed
symbol
NC
valve
normally open
symbol
4
ports
details needed for main valve
■ orifice
■ port
■ function NC/NO
■ operating pressure
■ flow rate
■ media
■ media temperature
■ ambient temperature
■ type of actuation
function
pressure range
Kv value
vacuum
pressure-vacuum
back pressure
media
details needed for pneumatic actuation
■ nominal voltage
■ type of protection
■ actuation pressure range min/max
■ low wattage coil, actuation pressure range 4-7 bar
■ pilot valve type
details needed for hydraulic actuation
■ actuation pressure range min/max
■ hydraulic control valve function
abrasive media
damping
flow direction
switching cycles
switching time
media temperature
ambient temperature
flush ports
leak ports
limit switches
manual override
approvals
mounting
weight
additional equipment
B
a
4
NO
b
a b
2
A
VSV-F
flanges PN 16/40
options
bar
NC
0-16/0-40
m³/h
leak rate
P1 P2
P2 > P1
opening
closing
AB
1/min
ms
°C
°C
special flanges
NO
90,0
gaseous - liquid - highly viscous gelatinous - pasty - contaminated
by throttles on pilot valve
as marked
50
opening 200-3000 closing 200-3000
direct mounted pilot valve 60
direct mounted pilot valve 50
via pilot valve
kg
power consumption
The valves‘ technical design is based
on media and application requirements.
This can lead to deviations from the general
specifications shown on the data sheet with
regards to the design, sealing materials and
characteristics.
protection
energized duty rating
connection
additional equipment
optional
max. temperature
If order or application specifications are
incomplete or imprecise there exists a risk of
an incorrect technical design of the valve for
the required application. As a consequence,
the physical and / or chemical properties of
the materials or seals used, may not be suitable for the intended application.
explosion proof
VSV-F 27,0
■ specifications not highlighted are standard
specifications highlighted in grey are optional
•
D-74670 Forchtenberg
•
Germany
bi-directional upon request
remote mounted pilot valve outside temperature range of media max.160°C
available
available
inductive/mechanical upon request
options
Un
Un
DC
AC
IP 65 (P54)
ED
DC 24V
special voltage upon request
special voltage upon request
AC 230V 50 Hz
4,8 W
2,5 W
pick up 11,0 VA holding 8,5 VA
acc. DIN 40 050
100%
plug acc. DIN EN 175301-803 form B, 4 positions x 90° / wire diameter 6-8 mm
illuminated plug with varistor
M12x1
connector acc. DESINA
connector acc. VDMA
media
60°C
ambient
50°C
EEx m II T5 nominal voltage Un
direct current 24 V
3,25 W
alternating current 230 V 50 Hz 2,90 W
power consumption
options
bar
4-10
cm³/stroke 75
main valve speed variable by throttles on pilot valve
preferably 5/2-way pilot valve
2/4
G 1/4
G 3/8
hydraulic specifications
actuation pressure range
by media
control
actuator ports
version available
upon request
pneumatic specifications
actuation pressure range
air consumption
cycle speed
control
actuator ports
< 10-6 mbar•l•s-1
pressure side max. 40 bar
vacuum side leak rate upon request
available (max. 16 bar)
LR/GL/WAZ
electrical specifications
nominal voltage
Gottfried-Müller-Str. 1
2
A
general specifications
•
b
a b
design pressure balanced, with spring return
body materials ⓪ aluminium
② steel, galvanized
③
⑤ without non-ferr. metals
④ steel, nickel plated
⑥ stainless steel
valve seat synthetic resin on metal
seal materials NBR
PTFE, FPM, CR, EPDM
Above stated body materials refer to
the valve port connections that get in contact with the media only!
müller co-ax ag
B
a
bar
10-30 / 30-60
upon request
preferably 4/2-way control valve
X/Y
G 1/4
•
fon +49(0)7947/828-0
options
NPT 1/4
•
fax +49(0)7947/828-11
•
Email [email protected]
type VSV-F 80
function:
NC
closed when not energized
B
d
A
D
4
X
80
225
2
Y
160
260
k
160
580
type VSV-F 80
DIN
ØD
Øk
Ød
16
2633
200
160
18
40
2635
200
160
18
function:
NO
open when not energized
4
X
B
d
A
D
2
Y
80
225
flanges PN
160
260
k
160
580
pneumatic actuation (separately)
14
4 2
12
5/2-way-pilot valve
flow rate 700 l/min
pressure range 3-10 bar
G 1/8
5 13
14
4 2
12
5 13
5/2-way-pilot valve ISO 1
flow rate 700 l/min
pressure range 3-10 bar G 1/4
The applic ation - specif ic layout relating to temperature, pressure c onditions, switching behavior, media and its c on sistency may restrict the range of use or nec essitate relevant modif ic ations to materials used and seal ar rangements.