Verbesserung der LC-Performance durch Integration neuer HDR-DA-Detektoren und Hybrid LC-SFC-Systeme von Agilent Technologies APPLICA 2012 Dr. Holger Stalz LC-MS Produktspezialist Agilent Technologies Schweiz Basel, 16. Oktober 2012 1 APPLICA 2012 16. Oktober 2012 30x Wider Linear UV range Quantification of widely different concentration levels in one single run Agilent 1200 Infinity High Dynamic Range (HDR-DAD) Solution Holger Stalz LC/MS Produktspezialist Agilent Technologies Schweiz 1260/1290 Infinity HDR-DAD 2 APPLICA 2012 16. Oktober 2012 History of DAD Linearity Gain The last 30 years 45.0 > 30 40.0 1200 Infinity HDR-DAD 35.0 >30X Linearity Linearity Gain 30.0 With HDR 25.0 20.0 15.0 10.0 5.0 1.4 1.7 2.0 1.4 1040 to 1090 1090 to 1050 1050 to 1100 1110 to 1200 (1995) (2006) 2.9 0.0 (1986) (1988) 1200 to 1290/60 (2010) 1200 to HDR (2011) Detector Model (Intro Year) 3 APPLICA 2012 16. Oktober 2012 Optofluidic Waveguides: Max-Light Flow Cells Total-internal reflection in a non-coated fused silica fiber 1260 / 1290 Infinity DAD Grating Mirror Programmable or fixed slit Deuterium Lamp Max-Light Cartridge Cell 10 mm or 60 mm path length 4 1024 element diode-array APPLICA 2012 16. Oktober 2012 Linearity, linear range and dynamic range 1200 Series Diode Array Detector, 10 mm flow cell Detector Signal [AU] Linear _ range 10 mm Upper _ Limit 3 Detector _ Noise 10 5 HDR- DAD Upper limit 2.0 Slope = Response Factor (Sensitivity) HDR- DAD Detector noise 7*10-6 Linear range Dynamic range LOD (3x S/N) 5 Conc (upper limit) linear range Conc (upper limit) dynamic range Conc [µg/mL] APPLICA 2012 16. Oktober 2012 30x Wider Linear Range with HDR-DAD 3.7 mm and 60 mm and Max-Light flow cell Detector Signal [AU/cm] 30x lower Limit of Detection (LOD) for impurity analysis - For samples with widely different concentration levels - no time consuming • reanalysis • recalibration • sample preparation 3.7 mm 60 mm 10 x higher sensitivity ~3x higher upper limit Conc [µg/mL] 30x lower Limit of Detection (LOD) 6 APPLICA 2012 16. Oktober 2012 1290/1260 High Dynamic Range – HDR Increasing Linear UV Range by >30x Technology DAD 1: 60mm Clustered DAD Cluster of two DADs DAD 1: 60 mm Cell – for low concentrations DAD 2: 3.7 mm Cell – for high concentrations Output: One, combined signal, normalized to 10 mm path length (HDR range: 0.6 x 10-6 to 6.7 AU/cm) vs for 1200 Series: 7 x 10-6 to 2 AU/cm) Control / Usability Like standard 1290/1260 DAD: Control, data analysis, reporting DAD 2: Investment Protection Existing 1290/1260 DAD can be upgraded (by 2nd DAD) 3.7mm 7 Existing 1100/1200 Systems can be upgraded (by two 1290 or 1260 DAD) APPLICA 2012 16. Oktober 2012 1290/1260 High Dynamic Range – HDR Increasing Linear UV Range by >30x DAD 1: 60mm For sample mixtures with widely different concentration levels: All sample information in one run, e.g. for fixed dose combinations shorter turnaround time higher instrument utilization reduced solvent and waste costs. Clustered DAD DAD 2: Up to 30x lower LOD, 15x lower LOQ (compare to 1100/1200 Series) for more reliable automated integration higher area precision of low levels impurities prepared for stronger regulations 3.7mm 8 genotoxins APPLICA 2012 16. Oktober 2012 Experimental Sample: Fixed Dose Combination drug was used: Paracetamol (200mg) and Chlorphenamine (2.5mg ), (1:80), other compounds are Vitamin C (150mg) and Caffeine (25mg) + further small impurities CH3 NH CH3 Paracetamol O N N Caffeine N N O HO CH3 H3C O Cl CH3 Chlorphenamine N CH3 HO Vitamine C O HO N H HO 9 O OH APPLICA 2012 16. Oktober 2012 2 Injections needed if a conventional DAD is used Paracetamol mAU Vitamin C 1000 800 1µl injection to determine the first 3 peaks 600 400 Chlorphenamine ? Caffeine 200 0 0 1 2 3 4 5 min mAU 3800 Vitamin C 3000 Paracetamol Detector saturation Outside the linear range 5µl injection to determine the last peak and further impurities The first 2 peaks are out of linear range 2000 Chlorphenamine 1000 Caffeine 0 0 10 1 2 3 4 5 min APPLICA 2012 16. Oktober 2012 Comparison of conventional DAD vs. HDR DAD, 5µl injection mAU Paracetamol 4000 3500 Vitamin C Red conventional DAD: 2 peaks out of linear range with 5µl injection Detector saturation Outside the linear range 3000 Green HDR-DAD: All peaks within linear range (up to 6AU) 2500 2000 1500 1000 Caffeine 500 Chlorphenamine 0 0 11 1 2 3 4 5 min APPLICA 2012 16. Oktober 2012 Summary With the Agilent HDR DAD the determination of low and high doses drugs is possible in one run wheras the complete determination of all drugs with a conventional DAD needs 2 injections with different injection volumes Further improved precision and lower detection limits are achieved compared to a conventional DAD 12 APPLICA 2012 16. Oktober 2012 13 APPLICA 2012 16. Oktober 2012 What is Supercritical Fluid Chromatography? Definitions: 1. Supercritical Fluid Chromatography is a chromatography technique based on the use of supercritical carbon dioxide as the mobile phase 2. Supercritical Fluid Chromatography (SFC) is a form of normal phase chromatography that is used for the analysis and purification of low to moderate molecular weight molecules. Principles are similar to those in HPLC however SFC typically utilizes CO2 as the mobile phase; therefore the entire chromatographic flow path must be pressurized. 14 APPLICA 2012 16. Oktober 2012 Benefits of SFC vs. LC • Unique selectivity (orthogonality to HPLC) • Premier choice for chiral compounds • Replacement for Normal-Phase-HPLC • Complimentary to RP-LC or HILIC • Speed of analysis (faster than LC) • Cheaper than LC • Green • Broad detector compatibility => 15 APPLICA 2012 16. Oktober 2012 Unique Features of the Agilent 1260 Infinity SFC Performance HPLC-like UV-Sensitivity The only SFC with 600 bar power range Seamless MS and ELSD connection Cost 10-15x lower operating costs with standard grade CO2 Lowest solvent consumption and waste generation From entry LC upgrade to complete high-end MS/SFC all in one hybrid SFC/UHPLC system Time 3 x faster than LC no significant equilibration to change from UHPLC to SFC with the Hybrid SFC/UHPLC Robustness Based on proven 1260 Infinity quality 19 APPLICA 2012 16. Oktober 2012 Product Overview: 3 Ways to get SFC from Agilent …. Hybrid SFC/UHPLC System Analytical SFC LC Upgrade to SFC • 1260 Infinity analytical SFC • LC pump (Quat, Binary) • 2pos/10port valve • Hybrid SFC/UHPLC kit • 1260 Infinity analytical SFC • Fusion A5n (Aurora) • 1260 SFC binary pump • SFC accessory kit Change from SFC to UHPLC Orthogonal Separation Power 17 Convert 1100/1200 to SFC Best SFC performance Most affordable APPLICA 2012 16. Oktober 2012 The Agilent 1260 Infinity SFC/UHPLC Hybrid System Two orthogonal techniques with a single system Simply switch the valve 18 APPLICA 2012 16. Oktober 2012 Hybrid System in SFC Mode HPLC Waste Loop back Restrictor 2 1 3 10 LC Pump out 9 4 8 5 6 BPR 7 LC Pump: G1310B or G1311B or G1312B SFC Waste SFC Pump outlet Detector out SFC Pump inlet SFC-Binary Pump 19 APPLICA 2012 16. Oktober 2012 Hybrid System in UHPLC Mode Waste Restrictor 2 3 10 LC Pump out 9 4 8 5 BPR LC Pump: G1310B or G1311B or G1312B 1 6 7 Detector out SFC Pump outlet SFC Pump inlet SFC-Binary Pump 20 APPLICA 2012 16. Oktober 2012 Why is orthogonal sample information important and what are the advantages of the Agilent Hybrid instrument? • Orthogonal method screening in one single system • Separate and detect impurities which co-elute when using a single technique • Resolve peaks of complex samples • Switch from SFC to UHPLC forth and back in a single sequence • No equilibration time between LC and SFC • Significant cost saving, only one system has to be purchased • Direct results comparison between SFC and LC • No instrument to instrument variation • Save lab space • The only vendor who can offer both techniques in one system 21 APPLICA 2012 16. Oktober 2012 Performance: Orthogonal Separation: SFC Mode 1 - Caffeine 2 - Theophylline 3 - Cortisone 4 - Prednisone 5 - Hydrocortisone 6 - Prednisolone 7 - Sulfomerazine 8 - Sulfaquinoxaline 8 Components SFC Conditions Column: Zorbax Rx-Sil, 150 mm, 5 um, 4.6 Temp 27 C Flow Rate 4ml/min Gradient: CO2 v Meth Time %B 0 5 3.9 45 4 5 22 APPLICA 2012 16. Oktober 2012 Performance: Orthogonal Separation: UHPLC Mode What to do if there is a resolution problem? 6 Components + 2 Co-Eluting Peak LC Conditions Column s– ACE/Poroshell 3.0 x 150mm Temp 45 C Flow Rate 1ml/min H20 v Meth Time %B 0 5 4.1 45 4.4 45 4.6 100 5.0 100 5.1 5 23 APPLICA 2012 16. Oktober 2012 Overlay SFC versus UHPLC mode 1 - Caffeine 2 - Theophylline 3 - Cortisone 4 - Prednisone 5 - Hydrocortisone 6 - Prednisolone 7 - Sulfomerazine 8 - Sulfaquinoxaline LC SFC 24 APPLICA 2012 16. Oktober 2012 Repeatability: SFC and LC in a single sequence SFC-Mode LC-Mode Part of a sequence with alternating SFC and LC batches 25 APPLICA 2012 16. Oktober 2012 Ich danke Ihnen für Ihre Aufmerksamkeit! Haben Sie Fragen? 26 APPLICA 2012 16. Oktober 2012
© Copyright 2024 ExpyDoc