Technical Information TI 110C/07/en/12.02 50065951 Conductivity Sensors ConduMax W CLS 19 Two-electrode sensors with cell constants k = 0.01 cm–1 or k = 0.1 cm–1 Application Measurement in pure and ultrapure water: • Monitoring ion exchangers • Reverse osmosis The measuring range of the sensors depends on the cell constant k: • k = 0.01 cm–1: 0.04 ... 20 µS/cm • k = 0.1 cm–1: 0.1 ... 200 µS/cm Sensors with a Pt 100 temperature sensor are used together with the conductivity measuring instruments Liquisys M CLM 223/253 equipped with automatic temperature compensation. For measurement of specific resistance, MΩ . cm measuring ranges are available in the menues of these transmitters. Your benefits • Installation in pipes or flow chambers • Pt 100 temperature sensor for temperature compensation • Compact design • Very good price Quality made by Endress+Hauser ISO 9001 ConduMax W CLS 19 Function and system design Measuring principle Conductive conductivity measurement AC The conductivity of liquids is measured with a measuring system that has two coaxially arranged electrodes like a capacitor. The electric resistance or its reciprocal value, the conductance G, is measured according to Ohm’s law. The specific conductivity κ is determined using the cell constant k that is independent from the sensor’s geometry. I U C07-CLXcxxxx-15-05-00-xx-001.eps `ÕVÌÛiÊV`ÕVÌÛÌÞÊi>ÃÕÀiiÌ *ÜiÀÊÃÕ««Þ ÕÀÀiÌÊiÌiÀ 1 6Ì>}iÊiÌiÀ Important properties ConduMax W CLS 19 • Electrodes • • • • 2 ConduMax W CLS 19 has coaxial measuring electrodes made of polished, stainless steel 1.4571 (AISI 316Ti). Temperature sensor In addition, a Pt 100 temperature sensor is installed to measure the medium temperature. Easy connection The sensors are connected via a 4-pole DIN-plug that can be secured with a screw. For introduction of the measuring cable, the plug is equipped with a Pg 9 cable gland. Installation The sensor can be installed directly via the NPT ½" process connection. Mounting the sensor in cross or T-pieces with DN 20 requires a PVC-threaded coupling that is available as accessory. For easy installation in cross or T-pieces with DN 32, 40 or 50, adapter couplings (made of PVC for cementing) and a 1½" clamp coupling (made of PVDF) are available as accessories. Durability The sensor is pressure-proof up to 6 bar (at 20 °C) and can be applied with temperatures of up to 60 °C (at 1 bar). Endress+Hauser ConduMax W CLS 19 Measuring system A complete measuring system comprises: • a CLS 19 conductivity sensor • a transmitter, e.g. Liquisys M CLM 253 • a CYK 71 measuring cable ENDRESS+HAUSER LIQUISYS M 2 1 REL 1 ALARM CAL REL 2 REL REL 1 E REL 2 3 C07-CLS19xxx-14-06-00-xx-001.eps i>ÃÕÀ}ÊÃÞÃÌiÊiÝ>«i £ `Õ>ÝÊ7Ê -Ê£ Ó µÕÃÞÃÊÊ ÊÓxÎÊÌÀ>ÃÌÌiÀ Î -«iV>Êi>ÃÕÀ}ÊV>Li Input Measured values Conductivity Temperature Cell constant k Depending on ordered version: k = 0.01 cm–1 k = 0.1 cm–1 Measuring ranges Conductivity k = 0.01 cm–1: k = 0.1 cm–1: Temperature Temperature sensor Pt 100 Cable specification The ConduMax W is connected to the measuring transmitter using the special measuring cable CYK 71. (referenced to water at 25 °C) 0.04 µS/cm ... 20 µS/cm 0.1 µS/cm ... 200 µS/cm –10 ... 60 °C Cable -«iV>Êi>ÃÕÀ}ÊV>LiÊ 9ÊÇ£ Endress+Hauser } Coax BK Coax inner ) 2 GN WH YE BN 3 } 1 screen (outer electrode) conductivity (inner electrode) Pt 100 Outer screen (PE measuring device) Sensor Pin n.c. C07-CYK71xxx-00-11-00-en-002.eps 3 ConduMax W CLS 19 Installation Installation instructions The sensors are mounted directly via the NPT ½" process connection. Optionally, the sensors can be installed in cross or T-pieces. £ *6 Ì Ài>`i`ÊVÕ«}ÊÃiiÊVViÃÃÀiî Ó `>«ÌiÀÊVÕ«}ÊvÀÊViiÌ}ÊvÀÊ ÊÎÓ]Ê{äÊÀÊ xäÊÃiiÊVViÃÃÀiÃÊÊÎÓ]Ê{äÊÀÊxä® Î ÀÃÃÊÀÊ/«iViÊ ÊÎÓ]Ê{äÊÀÊxä 2 1 35 3 C07-CLS15xxx-11-05-00-xx-001.eps ÃÌ>>ÌÊÊVÀÃÃÊÀÊ/«iVi When mounting the sensor, make sure that the measuring surfaces are completely wetted by the medium. When working in ultrapure water, ingress of air must be avoided since dissolved air, particularly CO2, may increase conductivity by up to 3 µS/cm. Environment Ingress protection IP 65 Process Process temperature -10 ... +60 °C Process pressure 6 bar (at 20 °C) Pressure/temperature load curve [bar] 6 5 4 3 2 1 [°C] -10 0 10 *ÀiÃÃÕÀiÉÌi«iÀ>ÌÕÀiÊ>`ÊVÕÀÛiÊvÊ -Ê£ 4 20 30 40 50 60 C07-CLS19xxx-05-05-00-xx-001.eps Endress+Hauser ConduMax W CLS 19 Mechanical construction Design, dimensions 2 1 3 NPT ½" 17 126 17 AF 36 73 4 } 5 Ø 16 C07-CLS19xxx-16-05-00-xx-001.eps -Ê£Ê`iÃ} £ iVÌÊ i>` Ó i>ÃÕÀ}ÊV>LiÊÕÌiÌ Î / Ài>`i`Êà >vÌÊ*-® { iVÌÀ`iÃÊV>Ý>ÞÊ>ÀÀ>}i`®Ê x i>ÃÕÀ}ÊÃÕÀv>Vi Weight approx. 0.1 kg Materials Electrodes Sensor shaft Process connection NPT ½" thread Cable connection Pg 9 cable gland -Ê£Ê`iÃà C07-CLS19xxx-06-05-00-en-001.eps stainless steel 1.4571 (AISI 316Ti) PES (Polyethersulfone) Ordering information Product structure ConduMax W CLS 19 Measuring range and cell constant A B Measuring range: 0.04 ... 20 µS/cm (k = 0.01) Measuring range: 0.1 ... 200 µS/cm (k = 0.1) Process connection and materials 1A Thread NPT ½", sensor shaft PES Measuring cable connection 1 4-pole connector with Pg 9 Temperature sensor A D CLS 19- Endress+Hauser Integrated Pt 100 temperature sensor Without temperature sensor complete order code 5 ConduMax W CLS 19 Accessories Installation ❑ PVC-threaded coupling For cementing in standard PVC cross or T-pieces with DN 20, with G ½ internal thread, selfsealing, ½” NPT sensor thread; order no. 50066536 ❑ PVC equalising sleeves AM For adaptation of the PVC-threaded coupling to larger nominal diameters, – AM 32 for installation into cross or T-pieces DN 32, order no. 50004738 – AM 40 for installation into cross or T-pieces DN 40, order no. 50004739 – AM 50 for installation into cross or T-pieces DN 50, order no. 50004740 ❑ PVDF-threaded coupling With G ½ internal thread and G 1 external thread, pressure-proof up to 12 bar (20 °C), max. temperature 120 °C, incl. O-ring, internal thread, self-sealing with NPT ½" sensor thread; order no. 50004381 ❑ Adapter clamp 1½" made of PVDF for mounting the conductivity sensor in a clamp adaption; order no. 50043781 Measuring cables ❑ Special measuring cable / extension cable CYK 71 for two-electrode conductivity sensors with built-in temperature sensor, 1 low-noise coaxial line, 4 auxiliary cores at 0,75 mm2 each with a common screen, outer diameter 7 mm / 0,25" Sold by the metre, minimum length 5 m Length 5 m Length 10 m Length 50 m Length 100 m Order no. 50085333 Order no. 50088280 Order no. 50088281 Order no. 50088284 Order no. 50088285 ❑ Junction box VBM for cable extension, with 10 terminals, IP 65 / NEMA 4X Cable entry Pg 13,5 Cable entry NPT ½" Order no. 50003987 Order no. 51500177 Calibration solutions ❑ Calibration solutions Precision solutions referred to SRM (Standard Reference Material) of NIST for qualified calibration of conductivity measuring systems according to ISO, accuracy ± 0,5 %, with temperature table, – CLY 11-A 74 µS/cm (reference temperature 25 °C), 500 ml; order no. 50081902 – CLY 11-B 149,6 µS/cm (reference temperature 25 °C), 500 ml; order no. 50081903 Calibration set ❑ Calibration set ConCal Conductivity calibration set for ultrapure water applications, complete, factory-calibrated measuring set with certificate, traceable to SRM of NIST and DKD, for comparative measurement in ultrapure water applications up to 10 µS/cm – 230 V AC, order no. 50083777 – 115 V AC, order no. 50083778 ❑ Recalibration ConCal Factory recalibration and new issue of calibration certificate, traceable to SRM of NIST and DKD, factory calibration procedure according to ASTM D-5391-93; order no. 51502486 6 Endress+Hauser ConduMax W CLS 19 Related products ❑ Conductive conductivity sensor ConduMax W CLS 15 For measurement in pure and ultrapure water, for ordering information, see the CLS 15 Technical Information (TI 109C/07/en) Documentation Transmitters ❑ Liquisys M CLM 223/253, Technical Information TI 193C/07/en; order no. 51500279 Calibration solutions ❑ Precision calibration solution CLY 11, Technical Information TI 162C/07/en; order no. 50086574 ConCal ❑ ConCal, Technical Information TI 163C/07/en; order no. 50085983 Related products ❑ ConduMax W CLS 15, Technical Information TI 109C/07/en; order no. 50065950 Endress+Hauser 7 Deutschland Vertrieb: • Beratung • Information • Auftrag • Bestellung Service: • Help-Desk • Feldservice • Ersatzteile/Reparatur • Kalibrierung Endress+Hauser Messtechnik GmbH+Co. KG Colmarer Straße 6 D-79576 Weil am Rhein Telefon: 0 800 EHVERTRIEB 0 800 3 48 37 87 E-Mail: [email protected] Telefon: 0 800 EHSERVICE 0 800 3 47 37 84 E-Mail: [email protected] Telefax: 0 800 EHFAXEN 0 800 3 43 29 36 Internet: www.de.endress.com Technische Büros in: Hamburg . Hannover . Ratingen . Frankfurt . Stuttgart . München . Teltow 08.02 TI 110C/07/en/12.02 50065951 Printed in Germany / FM+SGML 6.0 / DT Österreich Schweiz Endress+Hauser Messtechnik Ges.m.b.H. Lehnergasse 4 Endress+Hauser Metso AG Sternenhofstraße 21 A-1230 Wien Tel. (01) 8 80 56-0 Fax (01) 8 80 56-335 E-Mail: [email protected] CH-4153 Reinach/BL1 Tel. (0 61) 7 15 75 75 Fax (0 61) 7 11 16 50 E-Mail: [email protected] Internet: www.at.endress.com Internet: www.ch.endress.com
© Copyright 2024 ExpyDoc