目 次 1. 序論 ······································································ 1-1 1.1 目的 ····································································· 1-1 1.2 実施内容 ································································· 1-1 2. BWR-3 MarkⅠ型原子炉施設の事故進展解析 ····································· 2-1 2.1 主な解析条件 ······························································ 2-1 2.1.1 原子炉施設の概要 ························································ 2-1 2.1.2 原子炉施設のボリューム分割 ·············································· 2-1 2.1.3 炉心部のセル分割 ························································ 2-3 2.1.4 工学的安全施設 ·························································· 2-3 2.1.5 ソースターム評価モデル ·················································· 2-4 2.2 AM 操作が無い場合の事故進展挙動 ············································ 2-13 2.2.1 高圧・低圧注水失敗(TQUV) ················································ 2-15 2.2.2 小 LOCA 時の高圧・低圧注水失敗(S2QUV) ···································· 2-16 2.2.3 高圧注水・減圧失敗(TQUX) ················································ 2-17 2.2.4 電源喪失(TB) ···························································· 2-18 2.2.5 小 LOCA 時の電源喪失(S2B) ················································ 2-19 2.2.6 電源喪失(TBU) ··························································· 2-20 2.2.7 崩壊熱除去失敗(TW) ······················································ 2-21 2.2.8 小 LOCA 時の崩壊熱除去失敗(S2W) ·········································· 2-22 2.2.9 原子炉未臨界確保失敗(TC) ················································ 2-23 2.2.10 小 LOCA 時の原子炉未臨界確保失敗(S2C) ··································· 2-24 2.2.11 LOCA 時注水失敗(AE) ····················································· 2-25 2.2.12 インターフェイス LOCA(V) ················································ 2-26 2.3 AM 操作がある場合の事故進展挙動 ··········································· 2-75 2.3.1 2.3.1.1 圧力容器破損前または圧力容器破損後のベント作動 ·························· 2-77 圧力容器破損前のベント作動(TQUV) ······································ 2-77 iii 2.3.1.2 圧力容器破損後のベント作動(TQUV) ······································ 2-77 2.3.1.3 圧力容器破損前のベント作動(S2QUV) ····································· 2-77 2.3.1.4 圧力容器破損後のベント作動(S2QUV) ····································· 2-78 2.3.1.5 圧力容器破損前のベント作動(TQUX) ······································ 2-78 2.3.1.6 圧力容器破損後のベント作動(TQUX) ······································ 2-79 2.3.1.7 圧力容器破損前のベント作動(TW) ········································ 2-79 2.3.1.8 圧力容器破損前のベント作動(S2W) ······································· 2-79 2.3.1.9 圧力容器破損前のベント作動(TC) ········································ 2-79 2.3.1.10 圧力容器破損前のベント作動(S2C) ······································ 2-80 2.3.1.11 圧力容器破損前のベント作動(AE) ······································· 2-80 2.3.1.12 圧力容器破損後のベント作動(AE) ······································· 2-81 2.3.2 圧力容器破損前または圧力容器破損後の機器復旧 ···························· 2-82 2.3.2.1 圧力容器破損前の機器復旧(TQUV) ········································ 2-82 2.3.2.2 圧力容器破損後の機器復旧(TQUV) ········································ 2-82 2.3.3 圧力容器破損前または圧力容器破損後の電源復旧 ···························· 2-83 2.3.3.1 圧力容器破損前の電源復旧(TB) ·········································· 2-83 2.3.3.2 圧力容器破損後の電源復旧(TB) ·········································· 2-83 2.3.3.3 圧力容器破損前の電源復旧(TBU) ········································· 2-83 2.3.3.4 圧力容器破損後の電源復旧(TBU) ········································· 2-84 2.3.3.5 圧力容器破損前の電源復旧(S2B) ········································· 2-84 2.3.3.6 圧力容器破損後の電源復旧(S2B) ········································· 2-84 2.3.4 その他の注水、除熱手段等の効果確認 ······································ 2-85 2.3.4.1 CRD 注水(TQUV) ························································· 2-85 2.3.4.2 CUW 除熱(TQUV) ························································· 2-85 2.3.4.3 圧力容器破損前ドライウェルクーラ(TQUV) ································ 2-85 2.3.4.4 圧力容器破損後ドライウェルクーラ(TQUV) ································ 2-86 2.3.4.5 CRD 注水(TQUX) ························································· 2-87 2.3.4.6 CUW 除熱(TQUX) ························································· 2-87 2.3.4.7 圧力容器破損前ドライウェルクーラ(TQUX) ································ 2-87 2.3.4.8 圧力容器破損後ドライウェルクーラ(TQUX) ································ 2-88 iv 2.3.4.9 CRD 注水(AE) ··························································· 2-88 2.3.4.10 圧力容器破損前ドライウェルクーラ(AE) ································· 2-89 2.3.4.11 圧力容器破損後ドライウェルクーラ(AE) ································· 2-89 2.4 BWR-3 Mark I 型原子炉施設の事故進展解析結果の整理 ························· 2-186 2.4.1 AM 操作が無い場合の各事故進展の解析結果 ································· 2-186 2.4.2 AM 操作がある場合の各事故進展の解析結果 ································· 2-186 3. BWR-4 MarkⅠ型原子炉施設の事故進展解析 ····································· 3-1 3.1 主な解析条件 ······························································ 3-1 3.1.1 原子炉施設の概要 ························································ 3-1 3.1.2 原子炉施設のボリューム分割 ·············································· 3-1 3.1.3 炉心部のセル分割 ························································ 3-2 3.1.4 工学的安全施設 ·························································· 3-2 3.1.5 ソースターム評価モデル ·················································· 3-2 3.2 AM 操作が無い場合の事故進展挙動 ············································ 3-11 3.2.1 高圧・低圧注水失敗(TQUV) ················································ 3-12 3.2.2 小 LOCA 時の高圧・低圧注水失敗(S2QUV) ···································· 3-13 3.2.3 高圧注水・減圧失敗(TQUX) ················································ 3-14 3.2.4 電源喪失(TB) ···························································· 3-15 3.2.5 小 LOCA 時の電源喪失(S2B) ················································ 3-16 3.2.6 電源喪失(TBU) ··························································· 3-17 3.2.7 崩壊熱除去失敗(TW) ······················································ 3-18 3.2.8 小 LOCA 時の崩壊熱除去失敗(S2W) ·········································· 3-19 3.2.9 原子炉未臨界確保失敗(TC) ················································ 3-20 3.2.10 小 LOCA 時の原子炉未臨界確保失敗(S2C) ··································· 3-21 3.2.11 LOCA 時注水失敗(AE) ····················································· 3-22 3.2.12 インターフェイス LOCA(V) ················································ 3-23 3.3 AM 操作がある場合の事故進展挙動 ··········································· 3-72 3.3.1 3.3.1.1 圧力容器破損前または圧力容器破損後のベント作動 ·························· 3-74 圧力容器破損前のベント作動(TQUV) ······································ 3-74 v 3.3.1.2 圧力容器破損後のベント作動(TQUV) ······································ 3-74 3.3.1.3 圧力容器破損前のベント作動(S2QUV) ····································· 3-74 3.3.1.4 圧力容器破損後のベント作動(S2QUV) ····································· 3-75 3.3.1.5 圧力容器破損前のベント作動(TQUX) ······································ 3-75 3.3.1.6 圧力容器破損後のベント作動(TQUX) ······································ 3-75 3.3.1.7 圧力容器破損前のベント作動(TW) ········································ 3-76 3.3.1.8 圧力容器破損前のベント作動(S2W) ······································· 3-76 3.3.1.9 圧力容器破損前のベント作動(TC) ········································ 3-76 3.3.1.10 圧力容器破損前のベント作動(S2C) ······································ 3-77 3.3.1.11 圧力容器破損前のベント作動(AE) ······································· 3-77 3.3.1.12 圧力容器破損後のベント作動(AE) ······································· 3-77 3.3.2 圧力容器破損前または圧力容器破損後の機器復旧 ···························· 3-79 3.3.2.1 圧力容器破損前の機器復旧(TQUV) ········································ 3-79 3.3.2.2 圧力容器破損後の機器復旧(TQUV) ········································ 3-79 3.3.3 圧力容器破損前または圧力容器破損後の電源復旧 ···························· 3-80 3.3.3.1 圧力容器破損前の電源復旧(TB) ·········································· 3-80 3.3.3.2 圧力容器破損後の電源復旧(TB) ·········································· 3-80 3.3.3.3 圧力容器破損前の電源復旧(TBU) ········································· 3-80 3.3.3.4 圧力容器破損後の電源復旧(TBU) ········································· 3-80 3.3.3.5 圧力容器破損前の電源復旧(S2B) ········································· 3-81 3.3.3.6 圧力容器破損後の電源復旧(S2B) ········································· 3-81 3.3.4 その他の注水、除熱手段等の効果確認 ······································ 3-82 3.3.4.1 CRD 注水(TQUV) ························································· 3-82 3.3.4.2 CUW 除熱(TQUV) ························································· 3-82 3.3.4.3 圧力容器破損前ドライウェルクーラ(TQUV) ································ 3-82 3.3.4.4 圧力容器破損後ドライウェルクーラ(TQUV) ································ 3-83 3.3.4.5 CRD 注水(TQUX) ························································· 3-83 3.3.4.6 CUW 除熱(TQUX) ························································· 3-83 3.3.4.7 圧力容器破損前ドライウェルクーラ(TQUX) ································ 3-84 3.3.4.8 圧力容器破損後ドライウェルクーラ(TQUX) ································ 3-84 vi 3.3.4.9 CRD 注水(AE) ··························································· 3-85 3.3.4.10 圧力容器破損前ドライウェルクーラ(AE) ································· 3-85 3.3.4.11 圧力容器破損後ドライウェルクーラ(AE) ································· 3-85 3.4 BWR-4 Mark I 型原子炉施設の事故進展解析結果の整理 ························· 3-181 3.4.1 AM 操作が無い場合の各事故進展の解析結果 ································· 3-181 3.4.2 AM 操作がある場合の各事故進展の解析結果 ································· 3-181 4. BWR-5 Mark II 型原子炉施設の事故進展解析 ··································· 4-1 4.1 主な解析条件 ······························································ 4-1 4.1.1 原子炉施設の概要 ························································ 4-1 4.1.2 原子炉施設のボリューム分割 ·············································· 4-1 4.1.3 炉心部のセル分割 ························································ 4-2 4.1.4 工学的安全施設 ·························································· 4-2 4.1.5 ソースターム評価モデル ·················································· 4-2 4.2 AM 操作が無い場合の事故進展挙動 ············································ 4-11 4.2.1 高圧・低圧注水失敗(TQUV) ················································ 4-12 4.2.2 小 LOCA 時の高圧・低圧注水失敗(S2QUV) ···································· 4-13 4.2.3 高圧注水・減圧失敗(TQUX) ················································ 4-14 4.2.4 電源喪失(TB) ···························································· 4-15 4.2.5 小 LOCA 時の電源喪失(S2B) ················································ 4-16 4.2.6 電源喪失(TBU) ··························································· 4-17 4.2.7 崩壊熱除去失敗(TW) ······················································ 4-18 4.2.8 小 LOCA 時の崩壊熱除去失敗(S2W) ·········································· 4-19 4.2.9 原子炉未臨界確保失敗(TC) ················································ 4-20 4.2.10 小 LOCA 時の原子炉未臨界確保失敗(S2C) ··································· 4-21 4.2.11 LOCA 時注水失敗(AE) ····················································· 4-22 4.2.12 インターフェイス LOCA(V) ················································ 4-23 4.3 AM 操作がある場合の事故進展挙動 ··········································· 4-72 4.3.1 4.3.1.1 圧力容器破損前または圧力容器破損後のベント作動 ·························· 4-74 圧力容器破損前のベント作動(TQUV) ······································ 4-74 vii 4.3.1.2 圧力容器破損後のベント作動(TQUV) ······································ 4-74 4.3.1.3 圧力容器破損前のベント作動(S2QUV) ····································· 4-74 4.3.1.4 圧力容器破損後のベント作動(S2QUV) ····································· 4-75 4.3.1.5 圧力容器破損前のベント作動(TQUX) ······································ 4-75 4.3.1.6 圧力容器破損後のベント作動(TQUX) ······································ 4-75 4.3.1.7 圧力容器破損前のベント作動(TW) ········································ 4-76 4.3.1.8 圧力容器破損前のベント作動(S2W) ······································· 4-76 4.3.1.9 圧力容器破損前のベント作動(TC) ········································ 4-76 4.3.1.10 圧力容器破損前のベント作動(S2C) ······································ 4-77 4.3.1.11 圧力容器破損前のベント作動(AE) ······································· 4-77 4.3.1.12 圧力容器破損後のベント作動(AE) ······································· 4-77 4.3.2 圧力容器破損前または圧力容器破損後の機器復旧 ···························· 4-79 4.3.2.1 圧力容器破損前の機器復旧(TQUV) ········································ 4-79 4.3.2.2 圧力容器破損後の機器復旧(TQUV) ········································ 4-79 4.3.3 圧力容器破損前または圧力容器破損後の電源復旧 ···························· 4-80 4.3.3.1 圧力容器破損前の電源復旧(TB) ·········································· 4-80 4.3.3.2 圧力容器破損後の電源復旧(TB) ·········································· 4-80 4.3.3.3 圧力容器破損前の電源復旧(TBU) ········································· 4-80 4.3.3.4 圧力容器破損後の電源復旧(TBU) ········································· 4-80 4.3.3.5 圧力容器破損前の電源復旧(S2B) ········································· 4-81 4.3.3.6 圧力容器破損後の電源復旧(S2B) ········································· 4-81 4.3.4 その他の注水、除熱手段の効果確認 ········································ 4-82 4.3.4.1 CRD 注水(TQUV) ························································· 4-82 4.3.4.2 CUW 除熱(TQUV) ························································· 4-82 4.3.4.3 圧力容器破損前ドライウェルクーラ(TQUV) ································ 4-82 4.3.4.4 圧力容器破損後ドライウェルクーラ(TQUV) ································ 4-83 4.3.4.5 CRD 注水(TQUX) ························································· 4-83 4.3.4.6 CUW 除熱(TQUX) ························································· 4-84 4.3.4.7 圧力容器破損前ドライウェルクーラ(TQUX) ································ 4-84 4.3.4.8 圧力容器破損後ドライウェルクーラ(TQUX) ································ 4-84 viii 4.3.4.9 CRD 注水(AE) ··························································· 4-85 4.3.4.10 圧力容器破損前ドライウェルクーラ(AE) ································· 4-85 4.3.4.11 圧力容器破損後ドライウェルクーラ(AE) ································· 4-85 4.4 BWR-5 Mark II 型原子炉施設の事故進展解析結果の整理 ························ 4-182 4.4.1 AM 操作が無い場合の各事故進展の解析結果 ································· 4-182 4.4.2 AM 操作がある場合の各事故進展の解析結果 ································· 4-182 5. ABWR RCCV 型原子炉施設の事故進展解析 ········································ 5-1 5.1 主な解析条件 ······························································ 5-1 5.1.1 原子炉施設の概要 ························································ 5-1 5.1.2 原子炉施設のボリューム分割 ·············································· 5-1 5.1.3 炉心部のセル分割 ························································ 5-3 5.1.4 工学的安全施設 ·························································· 5-3 5.1.5 ソースターム評価モデル ·················································· 5-4 5.2 AM 操作が無い場合の事故進展挙動 ············································ 5-11 5.2.1 高圧・低圧注水失敗(TQUV) ················································ 5-12 5.2.2 小 LOCA 時の高圧・低圧注水失敗(S2QUV) ···································· 5-13 5.2.3 高圧注水・減圧失敗(TQUX) ················································ 5-14 5.2.4 電源喪失(TB) ···························································· 5-15 5.2.5 小 LOCA 時の電源喪失(S2B) ················································ 5-16 5.2.6 電源喪失(TBU) ··························································· 5-17 5.2.7 崩壊熱除去失敗(TW) ······················································ 5-18 5.2.8 小 LOCA 時の崩壊熱除去失敗(S2W) ·········································· 5-19 5.2.9 原子炉未臨界確保失敗(TC) ················································ 5-20 5.2.10 小 LOCA 時の原子炉未臨界確保失敗(S2C) ··································· 5-21 5.2.11 LOCA 時注水失敗(AE) ····················································· 5-22 5.2.12 インターフェイス LOCA(V) ················································ 5-23 5.3 AM 操作がある場合の事故進展挙動 ··········································· 5-72 5.3.1 5.3.1.1 圧力容器破損前または圧力容器破損後のベント作動 ·························· 5-74 圧力容器破損前のベント作動(TQUV) ······································ 5-74 ix 5.3.1.2 圧力容器破損後のベント作動(TQUV) ······································ 5-74 5.3.1.3 圧力容器破損前のベント作動(S2QUV) ····································· 5-74 5.3.1.4 圧力容器破損後のベント作動(S2QUV) ····································· 5-75 5.3.1.5 圧力容器破損前のベント作動(TQUX) ······································ 5-75 5.3.1.6 圧力容器破損後のベント作動(TQUX) ······································ 5-76 5.3.1.7 圧力容器破損前のベント作動(TW) ········································ 5-76 5.3.1.8 圧力容器破損前のベント作動(S2W) ······································· 5-76 5.3.1.9 圧力容器破損前のベント作動(TC) ········································ 5-76 5.3.1.10 圧力容器破損前のベント作動(S2C) ······································ 5-77 5.3.1.11 圧力容器破損前のベント作動(AE) ······································· 5-77 5.3.1.12 圧力容器破損後のベント作動(AE) ······································· 5-78 5.3.2 圧力容器破損前または圧力容器破損後の機器復旧 ···························· 5-79 5.3.2.1 圧力容器破損前の機器復旧(TQUV) ········································ 5-79 5.3.2.2 圧力容器破損後の機器復旧(TQUV) ········································ 5-79 5.3.3 圧力容器破損前または圧力容器破損後の電源復旧 ···························· 5-80 5.3.3.1 圧力容器破損前の電源復旧(TB) ·········································· 5-80 5.3.3.2 圧力容器破損後の電源復旧(TB) ·········································· 5-80 5.3.3.3 圧力容器破損前の電源復旧(TBU) ········································· 5-80 5.3.3.4 圧力容器破損後の電源復旧(TBU) ········································· 5-80 5.3.3.5 圧力容器破損前の電源復旧(S2B) ········································· 5-81 5.3.3.6 圧力容器破損後の電源復旧(S2B) ········································· 5-81 5.3.4 その他の注水、除熱手段の効果確認 ········································ 5-82 5.3.4.1 CRD 注水(TQUV) ························································· 5-82 5.3.4.2 CUW 除熱(TQUV) ························································· 5-82 5.3.4.3 圧力容器破損前ドライウェルクーラ(TQUV) ································ 5-83 5.3.4.4 圧力容器破損後ドライウェルクーラ(TQUV) ································ 5-83 5.3.4.5 CRD 注水(TQUX) ························································· 5-84 5.3.4.6 CUW 除熱(TQUX) ························································· 5-84 5.3.4.7 圧力容器破損前ドライウェルクーラ(TQUX) ································ 5-85 5.3.4.8 圧力容器破損後ドライウェルクーラ(TQUX) ································ 5-85 x 5.3.4.9 CRD 注水(AE) ··························································· 5-85 5.3.4.10 圧力容器破損前ドライウェルクーラ(AE) ································· 5-86 5.3.4.11 圧力容器破損後ドライウェルクーラ(AE) ································· 5-86 5.4 ABWR RCCV 型原子炉施設の事故進展解析結果の整理 ···························· 5-183 5.4.1 AM 操作が無い場合の各事故進展の解析結果 ································· 5-183 5.4.2 AM 操作がある場合の各事故進展の解析結果 ································· 5-183 6. 結論 ········································································ 6-1 参考文献 ······································································· 参-1 略語一覧 ······································································· 略-1 付録 A ソースターム、事故進展時間及び格納容器機能喪失頻度の整理 ················ 付 A-1 xi 表 1.1 解析対象事故シーケンス:BWR-3 ··············································· 1-4 表 1.1 解析対象事故シーケンス:BWR-4 ··············································· 1-6 表 1.1 解析対象事故シーケンス:BWR-5 ··············································· 1-8 表 1.1 解析対象事故シーケンス:ABWR ················································ 1-10 表 1.2 プラント損傷状態記号の説明 ················································· 1-12 表 1.3 格納容器機能喪失モードの記号の説明 ········································· 1-13 表 1.4 格納容器機能が健全なモードの記号の説明 ····································· 1-13 表 2.1-1 本解析で用いた BWR-3 MarkⅠ型原子炉施設の主要解析条件 ···················· 2-5 表 2.1-2 MELCOR コードの解析モデルに関する解析条件 ································ 2-6 表 2.1-3 MELCOR コードの物質種のグループ分け ······································ 2-7 AM 操作が無い場合の事故進展解析の解析ケース(BWR-3 MarkⅠ型:各プラント共通) 表 2.2-1 ·················································································· 2-14 表 2.2.1-1 高圧・低圧注水失敗(TQUV、BWR-3 MarkⅠ)の主要事象の発生時刻 ············ 2-27 表 2.2.2-1 小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-3 MarkⅠ)の 主要事象の発生時刻 ·················································· 2-28 表 2.2.3-1 高圧注水・減圧失敗(TQUX、BWR-3 MarkⅠ)の主要事象の発生時刻 ············ 2-29 表 2.2.4-1 電源喪失(TB、BWR-3 MarkⅠ)の主要事象の発生時刻························· 2-30 表 2.2.5-1 小 LOCA 時の電源喪失(S2B、BWR-3 MarkⅠ)の主要事象の発生時刻 ············ 2-31 表 2.2.6-1 電源喪失(TBU、BWR-3 MarkⅠ)の主要事象の発生時刻························ 2-32 表 2.2.7-1 崩壊熱除去失敗(TW、BWR-3 MarkⅠ)の主要事象の発生時刻 ·················· 2-33 表 2.2.8-1 小 LOCA 時の崩壊熱除去失敗(S2W、BWR-3 MarkⅠ)の主要事象の発生時刻 ······ 2-34 表 2.2.9-1 原子炉未臨界確保失敗(TC、BWR-3 MarkⅠ)の主要事象の発生時刻 ············ 2-35 表 2.2.10-1 小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-3 MarkⅠ)の 主要事象の発生時刻 ·················································· 2-36 表 2.2.11-1 LOCA 時注水失敗(AE、BWR-3 MarkⅠ)の主要事象の発生時刻 ················· 2-37 表 2.2.12-1 インターフェイス LOCA(V、BWR-3 MarkⅠ)の主要事象の発生時刻 ············ 2-38 表 2.3-1 AM 操作がある場合の事故進展解析の解析ケース(BWR-3 MarkⅠ) ················ 2-76 表 2.3.1.1-1 圧力容器破損前のベント作動(TQUV、BWR-3 MarkⅠ)の主要事象の発生時刻 ·· 2-91 表 2.3.1.2-1 圧力容器破損後のベント作動(TQUV、BWR-3 MarkⅠ)の主要事象の発生時刻 ·· 2-92 表 2.3.1.3-1 圧力容器破損前のベント作動(S2QUV、BWR-3 MarkⅠ)の主要事象の発生時刻 · 2-93 xiii 表 2.3.1.4-1 圧力容器破損後のベント作動(S2QUV、BWR-3 MarkⅠ)の主要事象の発生時刻 · 2-94 表 2.3.1.5-1 圧力容器破損前のベント作動(TQUX、BWR-3 MarkⅠ)の主要事象の発生時刻 ·· 2-95 表 2.3.1.6-1 圧力容器破損後のベント作動(TQUX、BWR-3 MarkⅠ)の主要事象の発生時刻 ·· 2-96 表 2.3.1.7-1 圧力容器破損前のベント作動(TW、BWR-3 MarkⅠ)の主要事象の発生時刻 ···· 2-97 表 2.3.1.8-1 圧力容器破損前のベント作動(S2W、BWR-3 MarkⅠ)の主要事象の発生時刻 ··· 2-98 表 2.3.1.9-1 圧力容器破損前のベント作動(TC、BWR-3 MarkⅠ)の主要事象の発生時刻 ···· 2-99 表 2.3.1.10-1 圧力容器破損前のベント作動(S2C、BWR-3 MarkⅠ)の主要事象の発生時刻 ·· 2-100 表 2.3.1.11-1 圧力容器破損前のベント作動(AE、BWR-3 MarkⅠ)の主要事象の発生時刻 ··· 2-101 表 2.3.1.12-1 圧力容器破損後のベント作動(AE、BWR-3 MarkⅠ)の主要事象の発生時刻 ··· 2-102 表 2.3.2.1-1 圧力容器破損前の機器復旧(TQUV、BWR-3 MarkⅠ)の主要事象の発生時刻 ···· 2-103 表 2.3.2.2-1 圧力容器破損後の機器復旧(TQUV、BWR-3 MarkⅠ)の主要事象の発生時刻 ···· 2-104 表 2.3.3.1-1 圧力容器破損前の電源復旧(TB、BWR-3 MarkⅠ)の主要事象の発生時刻 ······ 2-105 表 2.3.3.2-1 圧力容器破損後の電源復旧(TB、BWR-3 MarkⅠ)の主要事象の発生時刻 ······ 2-106 表 2.3.3.3-1 圧力容器破損前の電源復旧(TBU、BWR-3 MarkⅠ)の主要事象の発生時刻 ····· 2-107 表 2.3.3.4-1 圧力容器破損後の電源復旧(TBU、BWR-3 MarkⅠ)の主要事象の発生時刻 ····· 2-108 表 2.3.3.5-1 圧力容器破損前の電源復旧(S2B、BWR-3 MarkⅠ)の主要事象の発生時刻 ····· 2-109 表 2.3.3.6-1 圧力容器破損後の電源復旧(S2B、BWR-3 MarkⅠ)の主要事象の発生時刻 ····· 2-110 表 2.3.4.1-1 CRD 注水(TQUV、BWR-3 MarkⅠ)の主要事象の発生時刻 ····················· 2-111 表 2.3.4.2-1 CUW 除熱あり(TQUV、BWR-3 MarkⅠ)の主要事象の発生時刻 ················· 2-112 表 2.3.4.2-2 CUW 除熱なし(TQUV、BWR-3 MarkⅠ)の主要事象の発生時刻 ················· 2-113 表 2.3.4.3-1 圧力容器破損前 DW クーラ(TQUV、BWR-3 MarkⅠ)の主要事象の発生時刻 ····· 2-114 表 2.3.4.4-1 圧力容器破損後 DW クーラ(TQUV、BWR-3 MarkⅠ)の主要事象の発生時刻 ····· 2-115 表 2.3.4.5-1 CRD 注水(TQUX、BWR-3 MarkⅠ)の主要事象の発生時刻 ····················· 2-116 表 2.3.4.6-1 CUW 除熱あり(TQUX、BWR-3 MarkⅠ)の主要事象の発生時刻 ················· 2-117 表 2.3.4.6-2 CUW 除熱なし(TQUX、BWR-3 MarkⅠ)の主要事象の発生時刻 ················· 2-118 表 2.3.4.7-1 圧力容器破損前 DW クーラ(TQUX、BWR-3 MarkⅠ)の主要事象の発生時刻 ····· 2-119 表 2.3.4.8-1 圧力容器破損後 DW クーラ(TQUX、BWR-3 MarkⅠ)の主要事象の発生時刻 ····· 2-120 表 2.3.4.9-1 CRD 注水(AE、BWR-3 MarkⅠ)の主要事象の発生時刻 ······················· 2-121 表 2.3.4.10-1 圧力容器破損前 DW クーラ(AE、BWR-3 MarkⅠ)の主要事象の発生時刻 ······ 2-122 表 2.3.4.11-1 圧力容器破損後 DW クーラ(AE、BWR-3 MarkⅠ)の主要事象の発生時刻 ······ 2-123 xiv 表 2.4.1-1 ソースタームまとめ(BWR-3 MarkⅠ、AM なしの場合) ························ 2-187 表 2.4.1-2 格納容器内放出割合(BWR-3 MarkⅠ、AM なしの場合) ······················ 2-188 表 2.4.2-1 ソースタームまとめ(BWR-3 MarkⅠ、AM ありの場合) ························ 2-189 表 2.4.2-2 格納容器内放出割合(BWR-3 MarkⅠ、AM ありの場合) ······················ 2-190 表 3.1-1 本解析で用いた BWR-4 MarkⅠ型原子炉施設の主要解析条件 ···················· 3-4 表 3.2.1-1 高圧・低圧注水失敗(TQUV、BWR-4 MarkⅠ)の主要事象の発生時刻 ············ 3-24 表 3.2.2-1 小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-4 MarkⅠ)の 主要事象の発生時刻 ·················································· 3-25 表 3.2.3-1 高圧注水・減圧失敗(TQUX、BWR-4 MarkⅠ)の主要事象の発生時刻 ············ 3-26 表 3.2.4-1 電源喪失(TB、BWR-4 MarkⅠ)の主要事象の発生時刻························· 3-27 表 3.2.5-1 小 LOCA 時の電源喪失(S2B、BWR-4 MarkⅠ)の主要事象の発生時刻 ············ 3-28 表 3.2.6-1 電源喪失(TBU、BWR-4 MarkⅠ)の主要事象の発生時刻························ 3-29 表 3.2.7-1 崩壊熱除去失敗(TW、BWR-4 MarkⅠ)の主要事象の発生時刻 ·················· 3-30 表 3.2.8-1 小 LOCA 時の崩壊熱除去失敗(S2W、BWR-4 MarkⅠ)の主要事象の発生時刻 ······ 3-31 表 3.2.9-1 原子炉未臨界確保失敗(TC、BWR-4 MarkⅠ)の主要事象の発生時刻 ············ 3-32 表 3.2.10-1 小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-4 MarkⅠ)の 主要事象の発生時刻 ·················································· 3-33 表 3.2.11-1 LOCA 時注水失敗(AE、BWR-4 MarkⅠ)の主要事象の発生時刻 ················· 3-34 表 3.2.12-1 インターフェイス LOCA(V、BWR-4 MarkⅠ)の主要事象の発生時刻 ············ 3-35 表 3.3-1 AM 操作がある場合の事故進展解析の解析ケース(BWR-4 MarkⅠ) ··············· 3-73 表 3.3.1.1-1 圧力容器破損前のベント作動(TQUV、BWR-4 MarkⅠ)の主要事象の発生時刻 ·· 3-86 表 3.3.1.2-1 圧力容器破損後のベント作動(TQUV、BWR-4 MarkⅠ)の主要事象の発生時刻 ·· 3-87 表 3.3.1.3-1 圧力容器破損前のベント作動(S2QUV、BWR-4 MarkⅠ)の主要事象の発生時刻 · 3-88 表 3.3.1.4-1 圧力容器破損後のベント作動(S2QUV、BWR-4 MarkⅠ)の主要事象の発生時刻 · 3-89 表 3.3.1.5-1 圧力容器破損前のベント作動(TQUX、BWR-4 MarkⅠ)の主要事象の発生時刻 ·· 3-90 表 3.3.1.6-1 圧力容器破損後のベント作動(TQUX、BWR-4 MarkⅠ)の主要事象の発生時刻 ·· 3-91 表 3.3.1.7-1 圧力容器破損前のベント作動(TW、BWR-4 MarkⅠ)の主要事象の発生時刻 ···· 3-92 表 3.3.1.8-1 圧力容器破損前のベント作動(S2W、BWR-4 MarkⅠ)の主要事象の発生時刻 ··· 3-93 表 3.3.1.9-1 圧力容器破損前のベント作動(TC、BWR-4 MarkⅠ)の主要事象の発生時刻 ···· 3-94 表 3.3.1.10-1 圧力容器破損前のベント作動(S2C、BWR-4 MarkⅠ)の主要事象の発生時刻 ·· 3-95 xv 表 3.3.1.11-1 圧力容器破損前のベント作動(AE、BWR-4 MarkⅠ)の主要事象の発生時刻 ··· 3-96 表 3.3.1.12-1 圧力容器破損後のベント作動(AE、BWR-4 MarkⅠ)の主要事象の発生時刻 ··· 3-97 表 3.3.2.1-1 圧力容器破損前の機器復旧(TQUV、BWR-4 MarkⅠ)の主要事象の発生時刻 ···· 3-98 表 3.3.2.2-1 圧力容器破損後の機器復旧(TQUV、BWR-4 MarkⅠ)の主要事象の発生時刻 ···· 3-99 表 3.3.3.1-1 圧力容器破損前の電源復旧(TB、BWR-4 MarkⅠ)の主要事象の発生時刻 ······ 3-100 表 3.3.3.2-1 圧力容器破損後の電源復旧(TB、BWR-4 MarkⅠ)の主要事象の発生時刻 ······ 3-101 表 3.3.3.3-1 圧力容器破損前の電源復旧(TBU、BWR-4 MarkⅠ)の主要事象の発生時刻 ····· 3-102 表 3.3.3.4-1 圧力容器破損後の電源復旧(TBU、BWR-4 MarkⅠ)の主要事象の発生時刻 ····· 3-103 表 3.3.3.5-1 圧力容器破損前の電源復旧(S2B、BWR-4 MarkⅠ)の主要事象の発生時刻 ····· 3-104 表 3.3.3.6-1 圧力容器破損後の電源復旧(S2B、BWR-4 MarkⅠ)の主要事象の発生時刻 ····· 3-105 表 3.3.4.1-1 CRD 注水(TQUV、BWR-4 MarkⅠ)の主要事象の発生時刻 ····················· 3-106 表 3.3.4.2-1 CUW 除熱あり(TQUV、BWR-4 MarkⅠ)の主要事象の発生時刻 ················· 3-107 表 3.3.4.2-2 CUW 除熱なし(TQUV、BWR-4 MarkⅠ)の主要事象の発生時刻 ················· 3-108 表 3.3.4.3-1 圧力容器破損前 DW クーラ(TQUV、BWR-4 MarkⅠ)の主要事象の発生時刻 ····· 3-109 表 3.3.4.4-1 圧力容器破損後 DW クーラ(TQUV、BWR-4 MarkⅠ)の主要事象の発生時刻 ····· 3-110 表 3.3.4.5-1 CRD 注水(TQUX、BWR-4 MarkⅠ)の主要事象の発生時刻 ····················· 3-111 表 3.3.4.6-1 CUW 除熱あり(TQUX、BWR-4 MarkⅠ)の主要事象の発生時刻 ················· 3-112 表 3.3.4.6-2 CUW 除熱なし(TQUX、BWR-4 MarkⅠ)の主要事象の発生時刻 ················· 3-113 表 3.3.4.7-1 圧力容器破損前 DW クーラ(TQUX、BWR-4 MarkⅠ)の主要事象の発生時刻 ····· 3-114 表 3.3.4.8-1 圧力容器破損後 DW クーラ(TQUX、BWR-4 MarkⅠ)の主要事象の発生時刻 ····· 3-115 表 3.3.4.9-1 CRD 注水(AE、BWR-4 MarkⅠ)の主要事象の発生時刻 ······················· 3-116 表 3.3.4.10-1 圧力容器破損前 DW クーラ(AE、BWR-4 MarkⅠ)の主要事象の発生時刻 ······ 3-117 表 3.3.4.11-1 圧力容器破損後 DW クーラ(AE、BWR-4 MarkⅠ)の主要事象の発生時刻 ······ 3-118 表 3.4.1-1 ソースタームまとめ(BWR-4 MarkⅠ、AM なしの場合) ························ 3-182 表 3.4.1-2 格納容器内放出割合(BWR-4 MarkⅠ、AM なしの場合) ······················ 3-183 表 3.4.2-1 ソースタームまとめ(BWR-4 MarkⅠ、AM ありの場合) ························ 3-184 表 3.4.2-2 格納容器内放出割合(BWR-4 MarkⅠ、AM ありの場合) ······················ 3-185 表 4.1-1 本解析で用いた BWR-5 MarkⅡ型原子炉施設の主要解析条件 ···················· 4-4 表 4.2.1-1 高圧・低圧注水失敗(TQUV、BWR-5 MarkⅡ)の主要事象の発生時刻 ············ 4-24 表 4.2.2-1 小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-5 MarkⅡ)の xvi 主要事象の発生時刻 ·················································· 4-25 表 4.2.3-1 高圧注水・減圧失敗(TQUX、BWR-5 MarkⅡ)の主要事象の発生時刻 ············ 4-26 表 4.2.4-1 電源喪失(TB、BWR-5 MarkⅡ)の主要事象の発生時刻························· 4-27 表 4.2.5-1 小 LOCA 時の電源喪失(S2B、BWR-5 MarkⅡ)の主要事象の発生時刻 ············ 4-28 表 4.2.6-1 電源喪失(TBU、BWR-5 MarkⅡ)の主要事象の発生時刻························ 4-29 表 4.2.7-1 崩壊熱除去失敗(TW、BWR-5 MarkⅡ)の主要事象の発生時刻 ·················· 4-30 表 4.2.8-1 小 LOCA 時の崩壊熱除去失敗(S2W、BWR-5 MarkⅡ)の主要事象の発生時刻 ······ 4-31 表 4.2.9-1 原子炉未臨界確保失敗(TC、BWR-5 MarkⅡ)の主要事象の発生時刻 ············ 4-32 表 4.2.10-1 小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-5 MarkⅡ)の 主要事象の発生時刻 ·················································· 4-33 表 4.2.11-1 LOCA 時注水失敗(AE、BWR-5 MarkⅡ)の主要事象の発生時刻 ················· 4-34 表 4.2.12-1 インターフェイス LOCA(V、BWR-5 MarkⅡ)の主要事象の発生時刻 ············ 4-35 表 4.3-1 AM 操作がある場合の事故進展解析の解析ケース(BWR-5 MarkⅡ) ··············· 4-73 表 4.3.1.1-1 圧力容器破損前のベント作動(TQUV、BWR-5 MarkⅡ)の主要事象の発生時刻 ·· 4-87 表 4.3.1.2-1 圧力容器破損後のベント作動(TQUV、BWR-5 MarkⅡ)の主要事象の発生時刻 ·· 4-88 表 4.3.1.3-1 圧力容器破損前のベント作動(S2QUV、BWR-5 MarkⅡ)の主要事象の発生時刻 · 4-89 表 4.3.1.4-1 圧力容器破損後のベント作動(S2QUV、BWR-5 MarkⅡ)の主要事象の発生時刻 · 4-90 表 4.3.1.5-1 圧力容器破損前のベント作動(TQUX、BWR-5 MarkⅡ)の主要事象の発生時刻 ·· 4-91 表 4.3.1.6-1 圧力容器破損後のベント作動(TQUX、BWR-5 MarkⅡ)の主要事象の発生時刻 ·· 4-92 表 4.3.1.7-1 圧力容器破損前のベント作動(TW、BWR-5 MarkⅡ)の主要事象の発生時刻 ···· 4-93 表 4.3.1.8-1 圧力容器破損前のベント作動(S2W、BWR-5 MarkⅡ)の主要事象の発生時刻 ··· 4-94 表 4.3.1.9-1 圧力容器破損前のベント作動(TC、BWR-5 MarkⅡ)の主要事象の発生時刻 ···· 4-95 表 4.3.1.10-1 圧力容器破損前のベント作動(S2C、BWR-5 MarkⅡ)の主要事象の発生時刻 ·· 4-96 表 4.3.1.11-1 圧力容器破損前のベント作動(AE、BWR-5 MarkⅡ)の主要事象の発生時刻 ··· 4-97 表 4.3.1.12-1 圧力容器破損後のベント作動(AE、BWR-5 MarkⅡ)の主要事象の発生時刻 ··· 4-98 表 4.3.2.1-1 圧力容器破損前の機器復旧(TQUV、BWR-5 MarkⅡ)の主要事象の発生時刻 ···· 4-99 表 4.3.2.2-1 圧力容器破損後の機器復旧(TQUV、BWR-5 MarkⅡ)の主要事象の発生時刻 ···· 4-100 表 4.3.3.1-1 圧力容器破損前の電源復旧(TB、BWR-5 MarkⅡ)の主要事象の発生時刻 ······ 4-101 表 4.3.3.2-1 圧力容器破損後の電源復旧(TB、BWR-5 MarkⅡ)の主要事象の発生時刻 ······ 4-102 表 4.3.3.3-1 圧力容器破損前の電源復旧(TBU、BWR-5 MarkⅡ)の主要事象の発生時刻 ····· 4-103 xvii 表 4.3.3.4-1 圧力容器破損後の電源復旧(TBU、BWR-5 MarkⅡ)の主要事象の発生時刻 ····· 4-104 表 4.3.3.5-1 圧力容器破損前の電源復旧(S2B、BWR-5 MarkⅡ)の主要事象の発生時刻 ····· 4-105 表 4.3.3.6-1 圧力容器破損後の電源復旧(S2B、BWR-5 MarkⅡ)の主要事象の発生時刻 ····· 4-106 表 4.3.4.1-1 CRD 注水(TQUV、BWR-5 MarkⅡ)の主要事象の発生時刻 ····················· 4-107 表 4.3.4.2-1 CUW 除熱あり(TQUV、BWR-5 MarkⅡ)の主要事象の発生時刻 ················· 4-108 表 4.3.4.2-2 CUW 除熱なし(TQUV、BWR-5 MarkⅡ)の主要事象の発生時刻 ················· 4-109 表 4.3.4.3-1 圧力容器破損前 DW クーラ(TQUV、BWR-5 MarkⅡ)の主要事象の発生時刻 ····· 4-110 表 4.3.4.4-1 圧力容器破損後 DW クーラ(TQUV、BWR-5 MarkⅡ)の主要事象の発生時刻 ····· 4-111 表 4.3.4.5-1 CRD 注水(TQUX、BWR-5 MarkⅡ)の主要事象の発生時刻 ····················· 4-112 表 4.3.4.6-1 CUW 除熱あり(TQUX、BWR-5 MarkⅡ)の主要事象の発生時刻 ················· 4-113 表 4.3.4.6-2 CUW 除熱なし(TQUX、BWR-5 MarkⅡ)の主要事象の発生時刻 ················· 4-114 表 4.3.4.7-1 圧力容器破損前 DW クーラ(TQUX、BWR-5 MarkⅡ)の主要事象の発生時刻 ····· 4-115 表 4.3.4.8-1 圧力容器破損後 DW クーラ(TQUX、BWR-5 MarkⅡ)の主要事象の発生時刻 ····· 4-116 表 4.3.4.9-1 CRD 注水(AE、BWR-5 Mark Ⅱ)の主要事象の発生時刻 ······················ 4-117 表 4.3.4.10-1 圧力容器破損前 DW クーラ(AE、BWR-5 MarkⅡ)の主要事象の発生時刻 ······ 4-118 表 4.3.4.11-1 圧力容器破損後 DW クーラ(AE、BWR-5 MarkⅡ)の主要事象の発生時刻 ······ 4-119 表 4.4.1-1 ソースタームまとめ(BWR-5 MarkⅡ、AM なしの場合) ························ 4-183 表 4.4.1-2 格納容器内放出割合(BWR-5 MarkⅡ、AM なしの場合) ······················ 4-184 表 4.4.2-1 ソースタームまとめ(BWR-5 MarkⅡ、AM ありの場合) ························ 4-185 表 4.4.2-2 格納容器内放出割合(BWR-5 MarkⅡ、AM ありの場合) ······················ 4-186 表 5.1-1 本解析で用いた ABWR RCCV 型原子炉施設の主要解析条件 ······················ 5-5 表 5.2.1-1 高圧・低圧注水失敗(TQUV、ABWR RCCV)の主要事象の発生時刻 ··············· 5-24 表 5.2.2-1 小 LOCA 時の高圧・低圧注水失敗(S2QUV、ABWR RCCV)の 主要事象の発生時刻 ·················································· 5-25 表 5.2.3-1 高圧注水・減圧失敗(TQUX、ABWR RCCV)の主要事象の発生時刻 ··············· 5-26 表 5.2.4-1 電源喪失(TB、ABWR RCCV)の主要事象の発生時刻 ···························· 5-27 表 5.2.5-1 小 LOCA 時の電源喪失(S2B、ABWR RCCV)の主要事象の発生時刻 ··············· 5-28 表 5.2.6-1 電源喪失(TBU、ABWR RCCV)の主要事象の発生時刻··························· 5-29 表 5.2.7-1 崩壊熱除去失敗(TW、ABWR RCCV)の主要事象の発生時刻 ····················· 5-30 表 5.2.8-1 小 LOCA 時の崩壊熱除去失敗(S2W、ABWR RCCV)の主要事象の発生時刻 ········· 5-31 xviii 表 5.2.9-1 原子炉未臨界確保失敗(TC、ABWR RCCV)の主要事象の発生時刻 ··············· 5-32 表 5.2.10-1 小 LOCA 時の原子炉未臨界確保失敗(S2C、ABWR RCCV)の 主要事象の発生時刻 ·················································· 5-33 表 5.2.11-1 LOCA 時注水失敗(AE、ABWR RCCV)の主要事象の発生時刻 ···················· 5-34 表 5.2.12-1 インターフェイス LOCA(V、ABWR RCCV)の主要事象の発生時刻 ··············· 5-35 表 5.3-1 AM 操作がある場合の事故進展解析の解析ケース(ABWR RCCV) ··················· 5-73 表 5.3.1.1-1 圧力容器破損前のベント作動(TQUV、ABWR RCCV)の主要事象の発生時刻 ····· 5-88 表 5.3.1.2-1 圧力容器破損後のベント作動(TQUV、ABWR RCCV)の主要事象の発生時刻 ····· 5-89 表 5.3.1.3-1 圧力容器破損前のベント作動(S2QUV、ABWR RCCV)の主要事象の発生時刻 ···· 5-90 表 5.3.1.4-1 圧力容器破損後のベント作動(S2QUV、ABWR RCCV)の主要事象の発生時刻 ···· 5-91 表 5.3.1.5-1 圧力容器破損前のベント作動(TQUX、ABWR RCCV)の主要事象の発生時刻 ····· 5-92 表 5.3.1.6-1 圧力容器破損後のベント作動(TQUX、ABWR RCCV)の主要事象の発生時刻 ····· 5-93 表 5.3.1.7-1 圧力容器破損前のベント作動(TW、ABWR RCCV)の主要事象の発生時刻 ······· 5-94 表 5.3.1.8-1 圧力容器破損前のベント作動(S2W、ABWR RCCV)の主要事象の発生時刻 ······ 5-95 表 5.3.1.9-1 圧力容器破損前のベント作動(TC、ABWR RCCV)の主要事象の発生時刻 ······· 5-96 表 5.3.1.10-1 圧力容器破損前のベント作動(S2C、ABWR RCCV)の主要事象の発生時刻 ····· 5-97 表 5.3.1.11-1 圧力容器破損前のベント作動(AE、ABWR RCCV)の主要事象の発生時刻 ······ 5-98 表 5.3.1.12-1 圧力容器破損後のベント作動(AE、ABWR RCCV)の主要事象の発生時刻 ······ 5-99 表 5.3.2.1-1 圧力容器破損前の機器復旧(TQUV、ABWR RCCV)の主要事象の発生時刻 ······· 5-100 表 5.3.2.2-1 圧力容器破損後の機器復旧(TQUV、ABWR RCCV)の主要事象の発生時刻 ······· 5-101 表 5.3.3.1-1 圧力容器破損前の電源復旧(TB、ABWR RCCV)の主要事象の発生時刻 ········· 5-102 表 5.3.3.2-1 圧力容器破損後の電源復旧(TB、ABWR RCCV)の主要事象の発生時刻 ········· 5-103 表 5.3.3.3-1 圧力容器破損前の電源復旧(TBU、ABWR RCCV)の主要事象の発生時刻 ········ 5-104 表 5.3.3.4-1 圧力容器破損後の電源復旧(TBU、ABWR RCCV)の主要事象の発生時刻 ········ 5-105 表 5.3.3.5-1 圧力容器破損前の電源復旧(S2B、ABWR RCCV)の主要事象の発生時刻 ········ 5-106 表 5.3.3.6-1 圧力容器破損後の電源復旧(S2B、ABWR RCCV)の主要事象の発生時刻 ········ 5-107 表 5.3.4.1-1 CRD 注水(TQUV、ABWR RCCV)の主要事象の発生時刻 ························ 5-108 表 5.3.4.2-1 CUW 除熱あり(TQUV、ABWR RCCV)の主要事象の発生時刻 ···················· 5-109 表 5.3.4.2-2 CUW 除熱なし(TQUV、ABWR RCCV)の主要事象の発生時刻 ···················· 5-110 表 5.3.4.3-1 圧力容器破損前 DW クーラ(TQUV、ABWR RCCV)の主要事象の発生時刻 ········ 5-111 xix 表 5.3.4.4-1 圧力容器破損後 DW クーラ(TQUV、ABWR RCCV)の主要事象の発生時刻 ········ 5-112 表 5.3.4.5-1 CRD 注水(TQUX、ABWR RCCV)の主要事象の発生時刻 ························ 5-113 表 5.3.4.6-1 CUW 除熱あり(TQUX、ABWR RCCV)の主要事象の発生時刻 ···················· 5-114 表 5.3.4.6-2 CUW 除熱なし(TQUX、ABWR RCCV)の主要事象の発生時刻 ···················· 5-115 表 5.3.4.7-1 圧力容器破損前 DW クーラ(TQUX、ABWR RCCV)の主要事象の発生時刻 ········ 5-116 表 5.3.4.8-1 圧力容器破損後 DW クーラ(TQUX、ABWR RCCV)の主要事象の発生時刻 ········ 5-117 表 5.3.4.9-1 CRD 注水(AE、ABWR RCCV)の主要事象の発生時刻 ·························· 5-118 表 5.3.4.10-1 圧力容器破損前 DW クーラ(AE、ABWR RCCV)の主要事象の発生時刻 ········· 5-119 表 5.3.4.11-1 圧力容器破損後 DW クーラ(AE、ABWR RCCV)の主要事象の発生時刻 ········· 5-120 表 5.4.1-1 ソースタームまとめ(ABWR RCCV、AM なしの場合) ··························· 5-184 表 5.4.1-2 格納容器内放出割合(ABWR RCCV、AM なしの場合) ························· 5-185 表 5.4.2-1 ソースタームまとめ(ABWR RCCV、AM ありの場合) ··························· 5-186 表 5.4.2-2 格納容器内放出割合(ABWR RCCV、AM ありの場合) ························· 5-187 xx 図 2.1-1 BWR-3 MarkⅠ型原子炉格納施設概要 ······································· 2-8 図 2.1-2 BWR-3 型原子炉圧力容器内部構造図 ······································· 2-9 図 2.1-3 非常用炉心冷却系系統概要図(BWR-3 Mark-I) ····························· 2-10 図 2.1-4 BWR-3 MarkI 型原子炉施設のボリューム分割と流路 ························· 2-11 図 2.1-5 BWR-3 の炉心部のセル分割 ··············································· 2-12 図 2.2.1-1 原子炉冷却系水位(高圧・低圧注水失敗(TQUV、BWR-3 MarkⅠ)) ··········· 2-39 図 2.2.1-2 炉心最高温度(高圧・低圧注水失敗(TQUV、BWR-3 MarkⅠ)) ··············· 2-39 図 2.2.1-3 原子炉冷却系圧力(高圧・低圧注水失敗(TQUV、BWR-3 MarkⅠ)) ··········· 2-40 図 2.2.1-4 格納容器系圧力(高圧・低圧注水失敗(TQUV、BWR-3 MarkⅠ)) ············· 2-40 図 2.2.1-5 格納容器系温度(高圧・低圧注水失敗(TQUV、BWR-3 MarkⅠ)) ············· 2-41 図 2.2.1-6 格納容器系水位(高圧・低圧注水失敗(TQUV、BWR-3 MarkⅠ)) ············· 2-41 図 2.2.1-7 サプレッション・プールの水温 (高圧・低圧注水失敗(TQUV、BWR-3 MarkⅠ)) ··························· 2-42 図 2.2.1-8 各放射性物質の環境放出量割合 (高圧・低圧注水失敗(TQUV、BWR-3 MarkⅠ)) ·························· 2-42 図 2.2.2-1 原子炉冷却系水位 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-3 MarkⅠ)) ·············· 2-43 図 2.2.2-2 格納容器系圧力(小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-3 MarkⅠ)) · 2-43 図 2.2.2-3 格納容器系温度(小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-3 MarkⅠ)) · 2-44 図 2.2.2-4 各放射性物質の環境放出量割合 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-3 MarkⅠ)) ·············· 2-44 図 2.2.3-1 原子炉冷却系水位(高圧注水・減圧失敗(TQUX、BWR-3 MarkⅠ)) ··········· 2-45 図 2.2.3-2 格納容器系圧力(高圧注水・減圧失敗(TQUX、BWR-3 MarkⅠ)) ············· 2-45 図 2.2.3-3 格納容器系温度(高圧注水・減圧失敗(TQUX、BWR-3 MarkⅠ)) ············· 2-46 図 2.2.3-4 各放射性物質の環境放出割合(高圧注水・減圧失敗(TQUX、BWR-3 MarkⅠ))· 2-46 図 2.2.4-1 原子炉冷却系水位(電源喪失(TB、BWR-3 MarkⅠ)) ······················· 2-47 図 2.2.4-2 炉心最高温度(電源喪失(TB、BWR-3 MarkⅠ)) ··························· 2-47 図 2.2.4-3 原子炉冷却系圧力(電源喪失(TB、BWR-3 MarkⅠ)) ······················· 2-48 図 2.2.4-4 格納容器系圧力(電源喪失(TB、BWR-3 MarkⅠ)) ························· 2-48 図 2.2.4-5 格納容器系温度(電源喪失(TB、BWR-3 MarkⅠ)) ························· 2-49 xxi 図 2.2.4-6 格納容器系水位(電源喪失(TB、BWR-3 MarkⅠ)) ························· 2-49 図 2.2.4-7 サプレッション・プールの水温(電源喪失(TB、BWR-3 MarkⅠ)) ··········· 2-50 図 2.2.4-8 各放射性物質の環境放出量割合(電源喪失(TB、BWR-3 MarkⅠ)) ··········· 2-50 図 2.2.5-1 原子炉冷却系水位(小 LOCA 時の電源喪失(S2B、BWR-3 MarkⅠ)) ··········· 2-51 図 2.2.5-2 格納容器系圧力(小 LOCA 時の電源喪失(S2B、BWR-3 MarkⅠ)) ············· 2-51 図 2.2.5-3 格納容器系温度(小 LOCA 時の電源喪失(S2B、BWR-3 MarkⅠ)) ············· 2-52 図 2.2.5-4 各放射性物質の環境放出率(小 LOCA 時の電源喪失(S2B、BWR-3 MarkⅠ)) ··· 2-52 図 2.2.6-1 原子炉冷却系水位(電源喪失(TBU、BWR-3 MarkⅠ)) ······················ 2-53 図 2.2.6-2 格納容器系圧力(電源喪失(TBU、BWR-3 MarkⅠ)) ························ 2-53 図 2.2.6-3 格納容器系温度(電源喪失(TBU、BWR-3 MarkⅠ)) ························ 2-54 図 2.2.6-4 各放射性物質の環境放出量割合(電源喪失(TBU、BWR-3 MarkⅠ)) ·········· 2-54 図 2.2.7-1 原子炉冷却系水位(崩壊熱除去失敗(TW、BWR-3 MarkⅠ)) ················· 2-55 図 2.2.7-2 炉心最高温度(崩壊熱除去失敗(TW、BWR-3 MarkⅠ)) ····················· 2-55 図 2.2.7-3 原子炉冷却系圧力(崩壊熱除去失敗(TW、BWR-3 MarkⅠ)) ················· 2-56 図 2.2.7-4 格納容器系圧力(崩壊熱除去失敗(TW、BWR-3 MarkⅠ)) ··················· 2-56 図 2.2.7-5 格納容器系温度(崩壊熱除去失敗(TW、BWR-3 MarkⅠ)) ··················· 2-57 図 2.2.7-6 格納容器系水位(崩壊熱除去失敗(TW、BWR-3 MarkⅠ)) ··················· 2-57 図 2.2.7-7 サプレッション・プールの水温(崩壊熱除去失敗(TW、BWR-3 MarkⅠ)) ····· 2-58 図 2.2.7-8 各放射性物質の環境放出量割合(崩壊熱除去失敗(TW、BWR-3 MarkⅠ)) ····· 2-58 図 2.2.8-1 原子炉冷却系水位(小 LOCA 時の崩壊熱除去失敗(S2W、BWR-3 MarkⅠ)) ····· 2-59 図 2.2.8-2 格納容器系圧力(小 LOCA 時の崩壊熱除去失敗(S2W、BWR-3 MarkⅠ)) ······· 2-59 図 2.2.8-3 格納容器系温度(小 LOCA 時の崩壊熱除去失敗(S2W、BWR-3 MarkⅠ)) ······· 2-60 図 2.2.8-4 各放射性物質の環境放出量割合 (小 LOCA 時の崩壊熱除去失敗(S2W、BWR-3 MarkⅠ)) ···················· 2-60 図 2.2.9-1 原子炉冷却系水位(原子炉未臨界確保失敗(TC、BWR-3 MarkⅠ)) ··········· 2-61 図 2.2.9-2 炉心最高温度(原子炉未臨界確保失敗(TC、BWR-3 MarkⅠ)) ··············· 2-61 図 2.2.9-3 原子炉冷却系圧力(原子炉未臨界確保失敗(TC、BWR-3 MarkⅠ)) ··········· 2-62 図 2.2.9-4 格納容器系圧力(原子炉未臨界確保失敗(TC、BWR-3 MarkⅠ)) ············· 2-62 図 2.2.9-5 格納容器系温度(原子炉未臨界確保失敗(TC、BWR-3 MarkⅠ)) ············· 2-63 図 2.2.9-6 格納容器系水位(原子炉未臨界確保失敗(TC、BWR-3 MarkⅠ)) ············· 2-63 xxii 図 2.2.9-7 サプレッション・プールの水温 (原子炉未臨界確保失敗(TC、BWR-3 MarkⅠ)) ··························· 2-64 図 2.2.9-8 各放射性物質の環境放出量割合 (原子炉未臨界確保失敗(TC、BWR-3 MarkⅠ)) ·························· 2-64 図 2.2.10-1 原子炉冷却系水位 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-3 MarkⅠ)) ·············· 2-65 図 2.2.10-2 格納容器系圧力 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-3 MarkⅠ)) ·············· 2-65 図 2.2.10-3 格納容器系温度 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-3 MarkⅠ)) ·············· 2-66 図 2.2.10-4 各放射性物質の環境放出量割合 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-3 MarkⅠ)) ·············· 2-66 図 2.2.11-1 原子炉冷却系水位(LOCA 時注水失敗(AE、BWR-3 MarkⅠ)) ··············· 2-67 図 2.2.11-2 炉心最高温度(LOCA 時注水失敗(AE、BWR-3 MarkⅠ)) ··················· 2-67 図 2.2.11-3 原子炉冷却系圧力(LOCA 時注水失敗(AE、BWR-3 MarkⅠ)) ··············· 2-68 図 2.2.11-4 格納容器系圧力(LOCA 時注水失敗(AE、BWR-3 MarkⅠ)) ················· 2-68 図 2.2.11-5 格納容器系温度(LOCA 時注水失敗(AE、BWR-3 MarkⅠ)) ················· 2-69 図 2.2.11-6 格納容器系水位(LOCA 時注水失敗(AE、BWR-3 MarkⅠ)) ················· 2-69 図 2.2.11-7 サプレッション・プールの水温(LOCA 時注水失敗(AE、BWR-3 MarkⅠ)) ··· 2-70 図 2.2.11-8 各放射性物質の環境放出量割合(LOCA 時注水失敗(AE、BWR-3 MarkⅠ)) ··· 2-70 図 2.2.12-1 原子炉冷却系水位(インターフェイス LOCA(V、BWR-3 MarkⅠ)) ·········· 2-71 図 2.2.12-2 炉心最高温度(インターフェイス LOCA(V、BWR-3 MarkⅠ)) ·············· 2-71 図 2.2.12-3 原子炉冷却系圧力(インターフェイス LOCA(V、BWR-3 MarkⅠ)) ·········· 2-72 図 2.2.12-4 格納容器系圧力(インターフェイス LOCA(V、BWR-3 MarkⅠ)) ············ 2-72 図 2.2.12-5 格納容器系温度(インターフェイス LOCA(V、BWR-3 MarkⅠ)) ············ 2-73 図 2.2.12-6 格納容器系水位(インターフェイス LOCA(V、BWR-3 MarkⅠ)) ············ 2-73 図 2.2.12-7 サプレッション・プールの水温 (インターフェイス LOCA(V、BWR-3 MarkⅠ)) ···························· 2-74 図 2.2.12-8 各放射性物質の環境放出量割合 (インターフェイス LOCA(V、BWR-3 MarkⅠ)) ··························· 2-74 xxiii 図 2.3.1.1-1 格納容器系圧力(圧力容器破損前のベント作動(TQUV、BWR-3 MarkⅠ)) ··· 2-124 図 2.3.1.1-2 格納容器系温度(圧力容器破損前のベント作動(TQUV、BWR-3 MarkⅠ)) ··· 2-124 図 2.3.1.1-3 格納容器系水位(圧力容器破損前のベント作動(TQUV、BWR-3 MarkⅠ)) ··· 2-125 図 2.3.1.1-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TQUV、BWR-3 MarkⅠ)) ·················· 2-125 図 2.3.1.2-1 格納容器系圧力(圧力容器破損後のベント作動(TQUV、BWR-3 MarkⅠ)) ··· 2-126 図 2.3.1.2-2 格納容器系温度(圧力容器破損後のベント作動(TQUV、BWR-3 MarkⅠ)) ··· 2-126 図 2.3.1.2-3 格納容器系水位(圧力容器破損後のベント作動(TQUV、BWR-3 MarkⅠ)) ··· 2-127 図 2.3.1.2-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(TQUV、BWR-3 MarkⅠ)) ·················· 2-127 図 2.3.1.3-1 格納容器系圧力(圧力容器破損前のベント作動(S2QUV、BWR-3 MarkⅠ)) ·· 2-128 図 2.3.1.3-2 格納容器系温度(圧力容器破損前のベント作動(S2QUV、BWR-3 MarkⅠ)) ·· 2-128 図 2.3.1.3-3 格納容器系水位(圧力容器破損前のベント作動(S2QUV、BWR-3 MarkⅠ)) ·· 2-129 図 2.3.1.3-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(S2QUV、BWR-3 MarkⅠ)) ················· 2-129 図 2.3.1.4-1 格納容器系圧力(圧力容器破損後のベント作動(S2QUV、BWR-3 MarkⅠ)) ·· 2-130 図 2.3.1.4-2 格納容器系温度(圧力容器破損後のベント作動(S2QUV、BWR-3 MarkⅠ)) ·· 2-130 図 2.3.1.4-3 格納容器系水位(圧力容器破損後のベント作動(S2QUV、BWR-3 MarkⅠ)) ·· 2-131 図 2.3.1.4-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(S2QUV、BWR-3 MarkⅠ)) ················· 2-131 図 2.3.1.5-1 格納容器系圧力(圧力容器破損前のベント作動(TQUX、BWR-3 MarkⅠ)) ··· 2-132 図 2.3.1.5-2 格納容器系温度(圧力容器破損前のベント作動(TQUX、BWR-3 MarkⅠ)) ··· 2-132 図 2.3.1.5-3 格納容器系水位(圧力容器破損前のベント作動(TQUX、BWR-3 MarkⅠ)) ··· 2-133 図 2.3.1.5-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TQUX、BWR-3 MarkⅠ)) ·················· 2-133 図 2.3.1.6-1 格納容器系圧力(圧力容器破損後のベント作動(TQUX、BWR-3 MarkⅠ)) ··· 2-134 図 2.3.1.6-2 格納容器系温度(圧力容器破損後のベント作動(TQUX、BWR-3 MarkⅠ)) ··· 2-134 図 2.3.1.6-3 格納容器系水位(圧力容器破損後のベント作動(TQUX、BWR-3 MarkⅠ)) ··· 2-135 図 2.3.1.6-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(TQUX、BWR-3 MarkⅠ)) ·················· 2-135 xxiv 図 2.3.1.7-1 格納容器系圧力(圧力容器破損前のベント作動(TW、BWR-3 MarkⅠ)) ····· 2-136 図 2.3.1.7-2 格納容器系温度(圧力容器破損前のベント作動(TW、BWR-3 MarkⅠ)) ····· 2-136 図 2.3.1.7-3 格納容器系水位(圧力容器破損前のベント作動(TW、BWR-3 MarkⅠ)) ····· 2-137 図 2.3.1.7-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TW、BWR-3 MarkⅠ)) ···················· 2-137 図 2.3.1.8-1 格納容器系圧力(圧力容器破損前のベント作動(S2W、BWR-3 MarkⅠ)) ···· 2-138 図 2.3.1.8-2 格納容器系温度(圧力容器破損前のベント作動(S2W、BWR-3 MarkⅠ)) ···· 2-138 図 2.3.1.8-3 格納容器系水位(圧力容器破損前のベント作動(S2W、BWR-3 MarkⅠ)) ···· 2-139 図 2.3.1.8-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(S2W、BWR-3 MarkⅠ)) ··················· 2-139 図 2.3.1.9-1 格納容器系圧力(圧力容器破損前のベント作動(TC、BWR-3 MarkⅠ)) ····· 2-140 図 2.3.1.9-2 格納容器系温度(圧力容器破損前のベント作動(TC、BWR-3 MarkⅠ)) ····· 2-140 図 2.3.1.9-3 格納容器系水位(圧力容器破損前のベント作動(TC、BWR-3 MarkⅠ)) ····· 2-141 図 2.3.1.9-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TC、BWR-3 MarkⅠ)) ···················· 2-141 図 2.3.1.10-1 格納容器系圧力(圧力容器破損前のベント作動(S2C、BWR-3 MarkⅠ)) ··· 2-142 図 2.3.1.10-2 格納容器系温度(圧力容器破損前のベント作動(S2C、BWR-3 MarkⅠ)) ··· 2-142 図 2.3.1.10-3 格納容器系水位(圧力容器破損前のベント作動(S2C、BWR-3 MarkⅠ)) ··· 2-143 図 2.3.1.10-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(S2C、BWR-3 MarkⅠ)) ··················· 2-143 図 2.3.1.11-1 格納容器系圧力(圧力容器破損前のベント作動(AE、BWR-3 MarkⅠ)) ···· 2-144 図 2.3.1.11-2 格納容器系温度(圧力容器破損前のベント作動(AE、BWR-3 MarkⅠ)) ···· 2-144 図 2.3.1.11-3 格納容器系水位(圧力容器破損前のベント作動(AE、BWR-3 MarkⅠ)) ···· 2-145 図 2.3.1.11-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(AE、BWR-3 MarkⅠ)) ···················· 2-145 図 2.3.1.12-1 格納容器系圧力(圧力容器破損後のベント作動(AE、BWR-3 MarkⅠ)) ···· 2-146 図 2.3.1.12-2 格納容器系温度(圧力容器破損後のベント作動(AE、BWR-3 MarkⅠ)) ···· 2-146 図 2.3.1.12-3 格納容器系水位(圧力容器破損後のベント作動(AE、BWR-3 MarkⅠ)) ···· 2-147 図 2.3.1.12-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(AE、BWR-3 MarkⅠ)) ···················· 2-147 xxv 図 2.3.2.1-1 格納容器系圧力(圧力容器破損前の機器復旧(TQUV、BWR-3 MarkⅠ)) ····· 2-148 図 2.3.2.1-2 格納容器系温度(圧力容器破損前の機器復旧(TQUV、BWR-3 MarkⅠ)) ····· 2-148 図 2.3.2.1-3 格納容器系水位(圧力容器破損前の機器復旧(TQUV、BWR-3 MarkⅠ)) ····· 2-149 図 2.3.2.1-4 各放射性物質の環境放出量割合 (圧力容器破損前の機器復旧(TQUV、BWR-3 MarkⅠ)) ···················· 2-149 図 2.3.2.2-1 格納容器系圧力(圧力容器破損後の機器復旧(TQUV、BWR-3 MarkⅠ)) ····· 2-150 図 2.3.2.2-2 格納容器系温度(圧力容器破損後の機器復旧(TQUV、BWR-3 MarkⅠ)) ····· 2-150 図 2.3.2.2-3 格納容器系水位(圧力容器破損後の機器復旧(TQUV、BWR-3 MarkⅠ)) ····· 2-151 図 2.3.2.2-4 各放射性物質の環境放出量割合 (圧力容器破損後の機器復旧(TQUV、BWR-3 MarkⅠ)) ···················· 2-151 図 2.3.3.1-1 格納容器系圧力(圧力容器破損前の電源復旧(TB、BWR-3 MarkⅠ)) ······· 2-152 図 2.3.3.1-2 格納容器系温度(圧力容器破損前の電源復旧(TB、BWR-3 MarkⅠ)) ······· 2-152 図 2.3.3.1-3 格納容器系水位(圧力容器破損前の電源復旧(TB、BWR-3 MarkⅠ)) ······· 2-153 図 2.3.3.1-4 各放射性物質の環境放出量割合 (圧力容器破損前の電源復旧(TB、BWR-3 MarkⅠ)) ······················ 2-153 図 2.3.3.2-1 格納容器系圧力(圧力容器破損後の電源復旧(TB、BWR-3 MarkⅠ)) ······· 2-154 図 2.3.3.2-2 格納容器系温度(圧力容器破損後の電源復旧(TB、BWR-3 MarkⅠ)) ······· 2-154 図 2.3.3.2-3 格納容器系水位(圧力容器破損後の電源復旧(TB、BWR-3 MarkⅠ)) ······· 2-155 図 2.3.3.2-4 各放射性物質の環境放出量割合 (圧力容器破損後の電源復旧(TB、BWR-3 MarkⅠ)) ······················ 2-155 図 2.3.3.3-1 格納容器系圧力(圧力容器破損前の電源復旧(TBU、BWR-3 MarkⅠ)) ······ 2-156 図 2.3.3.3-2 格納容器系温度(圧力容器破損前の電源復旧(TBU、BWR-3 MarkⅠ)) ······ 2-156 図 2.3.3.3-3 格納容器系水位(圧力容器破損前の電源復旧(TBU、BWR-3 MarkⅠ)) ······ 2-157 図 2.3.3.3-4 各放射性物質の環境放出量割合 (圧力容器破損前の電源復旧(TBU、BWR-3 MarkⅠ)) ····················· 2-157 図 2.3.3.4-1 格納容器系圧力(圧力容器破損後の電源復旧(TBU、BWR-3 MarkⅠ)) ······ 2-158 図 2.3.3.4-2 格納容器系温度(圧力容器破損後の電源復旧(TBU、BWR-3 MarkⅠ)) ······ 2-158 図 2.3.3.4-3 格納容器系水位(圧力容器破損後の電源復旧(TBU、BWR-3 MarkⅠ)) ······ 2-159 図 2.3.3.4-4 各放射性物質の環境放出量割合 (圧力容器破損後の電源復旧(TBU、BWR-3 MarkⅠ)) ····················· 2-159 xxvi 図 2.3.3.5-1 格納容器系圧力(圧力容器破損前の電源復旧(S2B、BWR-3 MarkⅠ)) ······ 2-160 図 2.3.3.5-2 格納容器系温度(圧力容器破損前の電源復旧(S2B、BWR-3 MarkⅠ)) ······ 2-160 図 2.3.3.5-3 格納容器系水位(圧力容器破損前の電源復旧(S2B、BWR-3 MarkⅠ)) ······ 2-161 図 2.3.3.5-4 各放射性物質の環境放出量割合 (圧力容器破損前の電源復旧(S2B、BWR-3 MarkⅠ)) ····················· 2-161 図 2.3.3.6-1 格納容器系圧力(圧力容器破損後の電源復旧(S2B、BWR-3 MarkⅠ)) ······ 2-162 図 2.3.3.6-2 格納容器系温度(圧力容器破損後の電源復旧(S2B、BWR-3 MarkⅠ)) ······ 2-162 図 2.3.3.6-3 格納容器系水位(圧力容器破損後の電源復旧(S2B、BWR-3 MarkⅠ)) ······ 2-163 図 2.3.3.6-4 各放射性物質の環境放出量割合 (圧力容器破損後の電源復旧(S2B、BWR-3 MarkⅠ)) ····················· 2-163 図 2.3.4.1-1 格納容器系圧力(CRD 注水(TQUV、BWR-3 MarkⅠ)) ····················· 2-164 図 2.3.4.1-2 格納容器系温度(CRD 注水(TQUV、BWR-3 MarkⅠ)) ····················· 2-164 図 2.3.4.1-3 格納容器系水位(CRD 注水(TQUV、BWR-3 MarkⅠ)) ····················· 2-165 図 2.3.4.1-4 各放射性物質の環境放出量割合(CRD 注水(TQUV、BWR-3 MarkⅠ)) ······· 2-165 図 2.3.4.2-1 格納容器系圧力(CUW 除熱あり/なし(TQUV、BWR-3 MarkⅠ)) ············ 2-166 図 2.3.4.2-2 格納容器系温度(CUW 除熱あり/なし(TQUV、BWR-3 MarkⅠ)) ············ 2-166 図 2.3.4.2-3 各放射性物質の環境放出量割合(CUW 除熱あり(TQUV、BWR-3 MarkⅠ)) ··· 2-167 図 2.3.4.2-4 各放射性物質の環境放出量割合(CUW 除熱なし(TQUV、BWR-3 MarkⅠ)) ··· 2-167 図 2.3.4.3-1 格納容器系圧力(圧力容器破損前 DW クーラあり/なし(TQUV、BWR-3 MarkⅠ)) ················································································ 2-168 図 2.3.4.3-2 格納容器系温度(圧力容器破損前 DW クーラあり/なし(TQUV、BWR-3 MarkⅠ)) ················································································ 2-168 図 2.3.4.3-3 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラあり(TQUV、BWR-3 MarkⅠ)) ··············· 2-169 図 2.3.4.3-4 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラなし(TQUV、BWR-3 MarkⅠ)) ··············· 2-169 図 2.3.4.4-1 格納容器系圧力(圧力容器破損後 DW クーラあり/なし(TQUV、BWR-3 MarkⅠ)) ················································································ 2-170 図 2.3.4.4-2 格納容器系温度(圧力容器破損後 DW クーラあり/なし(TQUV、BWR-3 MarkⅠ)) ················································································ 2-170 xxvii 図 2.3.4.4-3 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラあり(TQUV、BWR-3 MarkⅠ)) ··············· 2-171 図 2.3.4.4-4 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラなし(TQUV、BWR-3 MarkⅠ)) ··············· 2-171 図 2.3.4.5-1 格納容器系圧力(CRD 注水(TQUX、BWR-3 MarkⅠ)) ····················· 2-172 図 2.3.4.5-2 格納容器系温度(CRD 注水(TQUX、BWR-3 MarkⅠ)) ····················· 2-172 図 2.3.4.5-3 格納容器系水位(CRD 注水(TQUX、BWR-3 MarkⅠ)) ····················· 2-173 図 2.3.4.5-4 各放射性物質の環境放出量割合(CRD 注水(TQUX、BWR-3 MarkⅠ)) ······· 2-173 図 2.3.4.6-1 格納容器系圧力(CUW 除熱あり/なし(TQUX、BWR-3 MarkⅠ)) ············ 2-174 図 2.3.4.6-2 格納容器系温度(CUW 除熱あり/なし(TQUX、BWR-3 MarkⅠ)) ············ 2-174 図 2.3.4.6-3 各放射性物質の環境放出量割合(CUW 除熱あり(TQUX、BWR-3 MarkⅠ)) ··· 2-175 図 2.3.4.6-4 各放射性物質の環境放出量割合(CUW 除熱なし(TQUX、BWR-3 MarkⅠ)) ··· 2-175 図 2.3.4.7-1 格納容器系圧力(圧力容器破損前 DW クーラあり/なし(TQUX、BWR-3 MarkⅠ)) ················································································ 2-176 図 2.3.4.7-2 格納容器系温度(圧力容器破損前 DW クーラあり/なし(TQUX、BWR-3 MarkⅠ)) ················································································ 2-176 図 2.3.4.7-3 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラあり(TQUX、BWR-3 MarkⅠ)) ··············· 2-177 図 2.3.4.7-4 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラなし(TQUX、BWR-3 MarkⅠ)) ··············· 2-177 図 2.3.4.8-1 格納容器系圧力(圧力容器破損後 DW クーラあり/なし(TQUX、BWR-3 MarkⅠ)) ················································································ 2-178 図 2.3.4.8-2 格納容器系温度(圧力容器破損後 DW クーラあり/なし(TQUX、BWR-3 MarkⅠ)) ················································································ 2-178 図 2.3.4.8-3 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラあり(TQUX、BWR-3 MarkⅠ)) ··············· 2-179 図 2.3.4.8-4 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラなし(TQUX、BWR-3 MarkⅠ)) ··············· 2-179 図 2.3.4.9-1 格納容器系圧力(CRD 注水(AE、BWR-3 MarkⅠ)) ······················· 2-180 図 2.3.4.9-2 格納容器系温度(CRD 注水(AE、BWR-3 MarkⅠ)) ······················· 2-180 xxviii 図 2.3.4.9-3 格納容器系水位(CRD 注水(AE、BWR-3 MarkⅠ)) ······················· 2-181 図 2.3.4.9-4 各放射性物質の環境放出量割合(CRD 注水(AE、BWR-3 MarkⅠ)) ········· 2-181 図 2.3.4.10-1 格納 容器系 圧力 (圧力 容器 破損 前 DW クーラ あり /なし(AE、 BWR-3 MarkⅠ)) ················································································ 2-182 図 2.3.4.10-2 格納 容器系 温度 (圧力 容器 破損 前 DW クーラ あり /なし(AE、 BWR-3 MarkⅠ)) ················································································ 2-182 図 2.3.4.10-3 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラあり(AE、BWR-3 MarkⅠ)) ················· 2-183 図 2.3.4.10-4 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラなし(AE、BWR-3 MarkⅠ)) ················· 2-183 図 2.3.4.11-1 格納 容器系 圧力 (圧力 容器 破損 後 DW クーラ あり /なし(AE、 BWR-3 MarkⅠ)) ················································································ 2-184 図 2.3.4.11-2 格納 容器系 温度 (圧力 容器 破損 後 DW クーラ あり /なし(AE、 BWR-3 MarkⅠ)) ················································································ 2-184 図 2.3.4.11-3 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラあり(AE、BWR-3 MarkⅠ)) ··················· 2-185 図 2.3.4.11-4 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラなし(AE、BWR-3 MarkⅠ)) ··················· 2-185 図 2.4.1-1 プラント内 FP 分布(高圧・低圧注水失敗(TQUV、BWR-3 MarkⅠ)) ·········· 2-193 図 2.4.1-2 プラント内 FP 分布 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-3 MarkⅠ)) ·············· 2-193 図 2.4.1-3 プラント内 FP 分布(高圧注水・減圧失敗(TQUX、BWR-3 MarkⅠ)) ·········· 2-194 図 2.4.1-4 プラント内 FP 分布(電源喪失(TB、BWR-3 MarkⅠ)) ······················ 2-194 図 2.4.1-5 プラント内 FP 分布(小 LOCA 時の電源喪失(S2B、BWR-3 MarkⅠ)) ·········· 2-195 図 2.4.1-6 プラント内 FP 分布(電源喪失(TBU、BWR-3 MarkⅠ)) ····················· 2-195 図 2.4.1-7 プラント内 FP 分布(崩壊熱除去失敗(TW、BWR-3 MarkⅠ)) ················ 2-196 図 2.4.1-8 プラント内 FP 分布(小 LOCA 時の崩壊熱除去失敗(S2W、BWR-3 MarkⅠ)) ···· 2-196 図 2.4.1-9 プラント内 FP 分布(原子炉未臨界確保失敗(TC、BWR-3 MarkⅠ)) ·········· 2-197 図 2.4.1-10 プラント内 FP 分布 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-3 MarkⅠ)) ·············· 2-197 xxix 図 2.4.1-11 プラント内 FP 分布(LOCA 時注水失敗(AE、BWR-3 MarkⅠ)) ·············· 2-198 図 2.4.1-12 プラント内 FP 分布(インターフェイス LOCA(V、BWR-3 MarkⅠ)) ········· 2-198 図 2.4.1-13 代表的な事故シーケンスの事故進展タイミング(BWR-3 MarkⅠ、AM なし) ··· 2-199 図 2.4.1-14 代表的な事故シーケンスのソースターム(BWR-3 MarkⅠ、AM なし) ········· 2-200 図 2.4.2-1 プラント内 FP 分布(圧力容器破損前のベント作動(TQUV、BWR-3 MarkⅠ)) ·· 2-201 図 2.4.2-2 プラント内 FP 分布(圧力容器破損後のベント作動(TQUV、BWR-3 MarkⅠ)) ·· 2-201 図 2.4.2-3 プラント内 FP 分布(圧力容器破損前のベント作動(TQUX、BWR-3 MarkⅠ)) ·· 2-202 図 2.4.2-4 プラント内 FP 分布(圧力容器破損後のベント作動(TQUX、BWR-3 MarkⅠ)) ·· 2-202 図 2.4.2-5 プラント内 FP 分布(圧力容器破損前のベント作動(TW、BWR-3 MarkⅠ)) ···· 2-203 図 2.4.2-6 プラント内 FP 分布(圧力容器破損前のベント作動(TC、BWR-3 MarkⅠ)) ···· 2-203 図 2.4.2-7 プラント内 FP 分布(圧力容器破損前のベント作動(S2C、BWR-3 MarkⅠ)) ··· 2-204 図 2.4.2-8 プラント内 FP 分布(圧力容器破損前のベント作動(AE、BWR-3 MarkⅠ)) ···· 2-204 図 2.4.2-9 プラント内 FP 分布(圧力容器破損後のベント作動(AE、BWR-3 MarkⅠ)) ···· 2-205 図 2.4.2-10 プラント内 FP 分布 (圧力容器破損前のベント作動(S2QUV、BWR-3 MarkⅠ)) ················· 2-205 図 2.4.2-11 プラント内 FP 分布 (圧力容器破損後のベント作動(S2QUV、BWR-3 MarkⅠ)) ················· 2-206 図 2.4.2-12 プラント内 FP 分布(圧力容器破損前のベント作動(S2W、BWR-3 MarkⅠ)) ·· 2-206 図 2.4.2-13 プラント内 FP 分布(圧力容器破損前の機器復旧(TQUV、BWR-3 MarkⅠ)) ··· 2-207 図 2.4.2-14 プラント内 FP 分布(圧力容器破損後の機器復旧(TQUV、BWR-3 MarkⅠ)) ··· 2-207 図 2.4.2-15 プラント内 FP 分布(圧力容器破損前の電源復旧(TB、BWR-3 MarkⅠ)) ····· 2-208 図 2.4.2-16 プラント内 FP 分布(圧力容器破損後の電源復旧(TB、BWR-3 MarkⅠ)) ····· 2-208 図 2.4.2-17 プラント内 FP 分布(圧力容器破損前の電源復旧(TBU、BWR-3 MarkⅠ)) ···· 2-209 図 2.4.2-18 プラント内 FP 分布(圧力容器破損後の電源復旧(TBU、BWR-3 MarkⅠ)) ···· 2-209 図 2.4.2-19 プラント内 FP 分布(圧力容器破損前の電源復旧(S2B、BWR-3 MarkⅠ)) ···· 2-210 図 2.4.2-20 プラント内 FP 分布(圧力容器破損後の電源復旧(S2B、BWR-3 MarkⅠ)) ···· 2-210 図 2.4.2-21 プラント内 FP 分布(CRD 注水(TQUV、BWR-3 MarkⅠ)) ··················· 2-211 図 2.4.2-22 プラント内 FP 分布(CUW 除熱あり(TQUV、BWR-3 MarkⅠ)) ··············· 2-211 図 2.4.2-23 プラント内 FP 分布(CUW 除熱なし(TQUV、BWR-3 MarkⅠ)) ··············· 2-212 xxx 図 2.4.2-24 プラント内 FP 分布(圧力容器破損前 DW クーラ(TQUV、BWR-3 MarkⅠ)) ···· 2-212 図 2.4.2-25 プラント内 FP 分布(圧力容器破損後 DW クーラ(TQUV、BWR-3 MarkⅠ)) ···· 2-213 図 2.4.2-26 プラント内 FP 分布(CRD 注水(TQUX、BWR-3 MarkⅠ)) ··················· 2-213 図 2.4.2-27 プラント内 FP 分布(CUW 除熱あり(TQUX、BWR-3 MarkⅠ)) ··············· 2-214 図 2.4.2-28 プラント内 FP 分布(CUW 除熱なし(TQUX、BWR-3 MarkⅠ)) ··············· 2-214 図 2.4.2-29 プラント内 FP 分布(圧力容器破損前 DW クーラ(TQUX、BWR-3 MarkⅠ)) ···· 2-215 図 2.4.2-30 プラント内 FP 分布(圧力容器破損後 DW クーラ(TQUX、BWR-3 MarkⅠ)) ···· 2-215 図 2.4.2-31 プラント内 FP 分布(CRD 注水(AE、BWR-3 MarkⅠ)) ····················· 2-216 図 2.4.2-32 プラント内 FP 分布(圧力容器破損前 DW クーラ(AE、BWR-3 MarkⅠ)) ······ 2-216 図 2.4.2-33 プラント内 FP 分布(圧力容器破損後 DW クーラ(AE、BWR-3 MarkⅠ)) ······ 2-217 図 2.4.2-34 代表的な事故シーケンスの事故進展タイミング(BWR-3 MarkⅠ、AM あり) ··· 2-218 図 2.4.2-35 代表的な事故シーケンスのソースターム(BWR-3 MarkⅠ、AM あり) ········· 2-219 図 3.1-1 BWR-4 MarkⅠ型原子炉格納施設概要 ······································· 3-5 図 3.1-2 BWR-4 MarkI 型原子炉施設のボリューム分割と流路 ························· 3-6 図 3.1-3 本解析で用いた炉心部のセル分割 ········································· 3-7 図 3.1-4 BWR-4 の炉心セルのモデル ··············································· 3-8 図 3.1-5 BWR-4 MarkI 型原子炉施設の非常用炉心冷却系系統概略図 ··················· 3-9 図 3.1-6 BWR-4 MarkI 型原子炉施設のECCS作動水位 ····························· 3-10 図 3.2.1-1 原子炉冷却系水位(高圧・低圧注水失敗(TQUV、BWR-4 MarkⅠ)) ··········· 3-36 図 3.2.1-2 炉心最高温度(高圧・低圧注水失敗(TQUV、BWR-4 MarkⅠ)) ··············· 3-36 図 3.2.1-3 原子炉冷却系圧力(高圧・低圧注水失敗(TQUV、BWR-4 MarkⅠ)) ··········· 3-37 図 3.2.1-4 格納容器系圧力(高圧・低圧注水失敗(TQUV、BWR-4 MarkⅠ)) ············· 3-37 図 3.2.1-5 格納容器系温度(高圧・低圧注水失敗(TQUV、BWR-4 MarkⅠ)) ············· 3-38 図 3.2.1-6 格納容器系水位(高圧・低圧注水失敗(TQUV、BWR-4 MarkⅠ)) ············· 3-38 図 3.2.1-7 サプレッション・プールの水温 (高圧・低圧注水失敗(TQUV、BWR-4 MarkⅠ)) ··························· 3-39 図 3.2.1-8 各放射性物質の環境放出量割合 (高圧・低圧注水失敗(TQUV、BWR-4 MarkⅠ)) ·························· 3-39 図 3.2.2-1 原子炉冷却系水位 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-4 MarkⅠ)) ·············· 3-40 xxxi 図 3.2.2-2 格納容器系圧力 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-4 MarkⅠ)) ·············· 3-40 図 3.2.2-3 格納容器系温度 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-4 MarkⅠ)) ·············· 3-41 図 3.2.2-4 各放射性物質の環境放出量割合 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-4 MarkⅠ)) ·············· 3-41 図 3.2.3-1 原子炉冷却系水位(高圧注水・減圧失敗(TQUX、BWR-4 MarkⅠ)) ··········· 3-42 図 3.2.3-2 格納容器系圧力(高圧注水・減圧失敗(TQUX、BWR-4 MarkⅠ)) ············· 3-42 図 3.2.3-3 格納容器系温度(高圧注水・減圧失敗(TQUX、BWR-4 MarkⅠ)) ············· 3-43 図 3.2.3-4 各放射性物質の環境放出量割合 (高圧注水・減圧失敗(TQUX、BWR-4 MarkⅠ)) ·························· 3-43 図 3.2.4-1 原子炉冷却系水位(電源喪失(TB、BWR-4 MarkⅠ)) ······················· 3-44 図 3.2.4-2 炉心最高温度(電源喪失(TB、BWR-4 MarkⅠ)) ··························· 3-44 図 3.2.4-3 原子炉冷却系圧力(電源喪失(TB、BWR-4 MarkⅠ)) ······················· 3-45 図 3.2.4-4 格納容器系圧力(電源喪失(TB、BWR-4 MarkⅠ)) ························· 3-45 図 3.2.4-5 格納容器系温度(電源喪失(TB、BWR-4 MarkⅠ)) ························· 3-46 図 3.2.4-6 格納容器系水位(電源喪失(TB、BWR-4 MarkⅠ)) ························· 3-46 図 3.2.4-7 サプレッション・プールの水温(電源喪失(TB、BWR-4 MarkⅠ)) ··········· 3-47 図 3.2.4-8 各放射性物質の環境放出量割合(電源喪失(TB、BWR-4 MarkⅠ)) ··········· 3-47 図 3.2.5-1 原子炉冷却系水位(小 LOCA 時の電源喪失(S2B、BWR-4 MarkⅠ)) ··········· 3-48 図 3.2.5-2 格納容器系圧力(小 LOCA 時の電源喪失(S2B、BWR-4 MarkⅠ)) ············· 3-48 図 3.2.5-3 格納容器系温度(小 LOCA 時の電源喪失(S2B、BWR-4 MarkⅠ)) ············· 3-49 図 3.2.5-4 各放射性物質の環境放出量割合 (小 LOCA 時の電源喪失(S2B、BWR-4 MarkⅠ)) ·························· 3-49 図 3.2.6-1 原子炉冷却系水位(電源喪失(TBU、BWR-4 MarkⅠ)) ······················ 3-50 図 3.2.6-2 格納容器系圧力(電源喪失(TBU、BWR-4 MarkⅠ)) ························ 3-50 図 3.2.6-3 格納容器系温度(電源喪失(TBU、BWR-4 MarkⅠ)) ························ 3-51 図 3.2.6-4 各放射性物質の環境放出量割合(電源喪失(TBU、BWR-4 MarkⅠ)) ·········· 3-51 図 3.2.7-1 原子炉冷却系水位(崩壊熱除去失敗(TW、BWR-4 MarkⅠ)) ················· 3-52 図 3.2.7-2 炉心最高温度(崩壊熱除去失敗(TW、BWR-4 MarkⅠ)) ····················· 3-52 xxxii 図 3.2.7-3 原子炉冷却系圧力(崩壊熱除去失敗(TW、BWR-4 MarkⅠ)) ················· 3-53 図 3.2.7-4 格納容器系圧力(崩壊熱除去失敗(TW、BWR-4 MarkⅠ)) ··················· 3-53 図 3.2.7-5 格納容器系温度(崩壊熱除去失敗(TW、BWR-4 MarkⅠ)) ··················· 3-54 図 3.2.7-6 格納容器系水位(崩壊熱除去失敗(TW、BWR-4 MarkⅠ)) ··················· 3-54 図 3.2.7-7 サプレッション・プールの水温(崩壊熱除去失敗(TW、BWR-4 MarkⅠ)) ····· 3-55 図 3.2.7-8 各放射性物質の環境放出量割合(崩壊熱除去失敗(TW、BWR-4 MarkⅠ)) ····· 3-55 図 3.2.8-1 原子炉冷却系水位(小 LOCA 時の崩壊熱除去失敗(S2W、BWR-4 MarkⅠ)) ····· 3-56 図 3.2.8-2 格納容器系圧力(小 LOCA 時の崩壊熱除去失敗(S2W、BWR-4 MarkⅠ)) ······· 3-56 図 3.2.8-3 格納容器系温度(小 LOCA 時の崩壊熱除去失敗(S2W、BWR-4 MarkⅠ)) ······· 3-57 図 3.2.8-4 各放射性物質の環境放出量割合 (小 LOCA 時の崩壊熱除去失敗(S2W、BWR-4 MarkⅠ)) ···················· 3-57 図 3.2.9-1 原子炉冷却系水位(原子炉未臨界確保失敗(TC、BWR-4 MarkⅠ)) ··········· 3-58 図 3.2.9-2 炉心最高温度(原子炉未臨界確保失敗(TC、BWR-4 MarkⅠ)) ··············· 3-58 図 3.2.9-3 原子炉冷却系圧力(原子炉未臨界確保失敗(TC、BWR-4 MarkⅠ)) ··········· 3-59 図 3.2.9-4 格納容器系圧力(原子炉未臨界確保失敗(TC、BWR-4 MarkⅠ)) ············· 3-59 図 3.2.9-5 格納容器系温度(原子炉未臨界確保失敗(TC、BWR-4 MarkⅠ)) ············· 3-60 図 3.2.9-6 格納容器系水位(原子炉未臨界確保失敗(TC、BWR-4 MarkⅠ)) ············· 3-60 図 3.2.9-7 サプレッション・プールの水温 (原子炉未臨界確保失敗(TC、BWR-4 MarkⅠ)) ··························· 3-61 図 3.2.9-8 各放射性物質の環境放出量割合 (原子炉未臨界確保失敗(TC、BWR-4 MarkⅠ)) ·························· 3-61 図 3.2.10-1 原子炉冷却系水位 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-4 MarkⅠ)) ·············· 3-62 図 3.2.10-2 格納容器系圧力 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-4 MarkⅠ)) ·············· 3-62 図 3.2.10-3 格納容器系温度 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-4 MarkⅠ)) ·············· 3-63 図 3.2.10-4 各放射性物質の環境放出量割合 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-4 MarkⅠ)) ·············· 3-63 図 3.2.11-1 原子炉冷却系水位(LOCA 時注水失敗(AE、BWR-4 MarkⅠ)) ··············· 3-64 xxxiii 図 3.2.11-2 炉心最高温度(LOCA 時注水失敗(AE、BWR-4 MarkⅠ)) ··················· 3-64 図 3.2.11-3 原子炉冷却系圧力(LOCA 時注水失敗(AE、BWR-4 MarkⅠ)) ··············· 3-65 図 3.2.11-4 格納容器系圧力(LOCA 時注水失敗(AE、BWR-4 MarkⅠ)) ················· 3-65 図 3.2.11-5 格納容器系温度(LOCA 時注水失敗(AE、BWR-4 MarkⅠ)) ················· 3-66 図 3.2.11-6 格納容器系水位(LOCA 時注水失敗(AE、BWR-4 MarkⅠ)) ················· 3-66 図 3.2.11-7 サプレッション・プールの水温(LOCA 時注水失敗(AE、BWR-4 MarkⅠ)) ··· 3-67 図 3.2.11-8 各放射性物質の環境放出量割合(LOCA 時注水失敗(AE、BWR-4 MarkⅠ)) ··· 3-67 図 3.2.12-1 原子炉冷却系水位(インターフェイス LOCA(V、BWR-4 MarkⅠ)) ·········· 3-68 図 3.2.12-2 炉心最高温度(インターフェイス LOCA(V、BWR-4 MarkⅠ)) ·············· 3-68 図 3.2.12-3 原子炉冷却系圧力(インターフェイス LOCA(V、BWR-4 MarkⅠ)) ·········· 3-69 図 3.2.12-4 格納容器系圧力(インターフェイス LOCA(V、BWR-4 MarkⅠ)) ············ 3-69 図 3.2.12-5 格納容器系温度(インターフェイス LOCA(V、BWR-4 MarkⅠ)) ············ 3-70 図 3.2.12-6 格納容器系水位(インターフェイス LOCA(V、BWR-4 MarkⅠ)) ············ 3-70 図 3.2.12-7 サプレッション・プールの水温 (インターフェイス LOCA(V、BWR-4 MarkⅠ)) ···························· 3-71 図 3.2.12-8 各放射性物質の環境放出量割合 (インターフェイス LOCA(V、BWR-4 MarkⅠ)) ··························· 3-71 図 3.3.1.1-1 格納容器系圧力(圧力容器破損前のベント作動(TQUV、BWR-4 MarkⅠ)) ··· 3-119 図 3.3.1.1-2 格納容器系温度(圧力容器破損前のベント作動(TQUV、BWR-4 MarkⅠ)) ··· 3-119 図 3.3.1.1-3 格納容器系水位(圧力容器破損前のベント作動(TQUV、BWR-4 MarkⅠ)) ··· 3-120 図 3.3.1.1-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TQUV、BWR-4 MarkⅠ)) ·················· 3-120 図 3.3.1.2-1 格納容器系圧力(圧力容器破損後のベント作動(TQUV、BWR-4 MarkⅠ)) ··· 3-121 図 3.3.1.2-2 格納容器系温度(圧力容器破損後のベント作動(TQUV、BWR-4 MarkⅠ)) ··· 3-121 図 3.3.1.2-3 格納容器系水位(圧力容器破損後のベント作動(TQUV、BWR-4 MarkⅠ)) ··· 3-122 図 3.3.1.2-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(TQUV、BWR-4 MarkⅠ)) ·················· 3-122 図 3.3.1.3-1 格納容器系圧力(圧力容器破損前のベント作動(S2QUV、BWR-4 MarkⅠ)) ·· 3-123 図 3.3.1.3-2 格納容器系温度(圧力容器破損前のベント作動(S2QUV、BWR-4 MarkⅠ)) ·· 3-123 図 3.3.1.3-3 格納容器系水位(圧力容器破損前のベント作動(S2QUV、BWR-4 MarkⅠ)) ·· 3-124 xxxiv 図 3.3.1.3-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(S2QUV、BWR-4 MarkⅠ)) ················· 3-124 図 3.3.1.4-1 格納容器系圧力(圧力容器破損後のベント作動(S2QUV、BWR-4 MarkⅠ)) ·· 3-125 図 3.3.1.4-2 格納容器系温度(圧力容器破損後のベント作動(S2QUV、BWR-4 MarkⅠ)) ·· 3-125 図 3.3.1.4-3 格納容器系水位(圧力容器破損後のベント作動(S2QUV、BWR-4 MarkⅠ)) ·· 3-126 図 3.3.1.4-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(S2QUV、BWR-4 MarkⅠ)) ················· 3-126 図 3.3.1.5-1 格納容器系圧力(圧力容器破損前のベント作動(TQUX、BWR-4 MarkⅠ)) ··· 3-127 図 3.3.1.5-2 格納容器系温度(圧力容器破損前のベント作動(TQUX、BWR-4 MarkⅠ)) ··· 3-127 図 3.3.1.5-3 格納容器系水位(圧力容器破損前のベント作動(TQUX、BWR-4 MarkⅠ)) ··· 3-128 図 3.3.1.5-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TQUX、BWR-4 MarkⅠ)) ·················· 3-128 図 3.3.1.6-1 格納容器系圧力(圧力容器破損後のベント作動(TQUX、BWR-4 MarkⅠ)) ··· 3-129 図 3.3.1.6-2 格納容器系温度(圧力容器破損後のベント作動(TQUX、BWR-4 MarkⅠ)) ··· 3-129 図 3.3.1.6-3 格納容器系水位(圧力容器破損後のベント作動(TQUX、BWR-4 MarkⅠ)) ··· 3-130 図 3.3.1.6-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(TQUX、BWR-4 MarkⅠ)) ·················· 3-130 図 3.3.1.7-1 格納容器系圧力(圧力容器破損前のベント作動(TW、BWR-4 MarkⅠ)) ····· 3-131 図 3.3.1.7-2 格納容器系温度(圧力容器破損前のベント作動(TW、BWR-4 MarkⅠ)) ····· 3-131 図 3.3.1.7-3 格納容器系水位(圧力容器破損前のベント作動(TW、BWR-4 MarkⅠ)) ····· 3-132 図 3.3.1.7-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TW、BWR-4 MarkⅠ)) ···················· 3-132 図 3.3.1.8-1 格納容器系圧力(圧力容器破損前のベント作動(S2W、BWR-4 MarkⅠ)) ···· 3-133 図 3.3.1.8-2 格納容器系温度(圧力容器破損前のベント作動(S2W、BWR-4 MarkⅠ)) ···· 3-133 図 3.3.1.8-3 格納容器系水位(圧力容器破損前のベント作動(S2W、BWR-4 MarkⅠ)) ···· 3-134 図 3.3.1.8-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(S2W、BWR-4 MarkⅠ)) ··················· 3-134 図 3.3.1.9-1 格納容器系圧力(圧力容器破損前のベント作動(TC、BWR-4 MarkⅠ)) ····· 3-135 図 3.3.1.9-2 格納容器系温度(圧力容器破損前のベント作動(TC、BWR-4 MarkⅠ)) ····· 3-135 図 3.3.1.9-3 格納容器系水位(圧力容器破損前のベント作動(TC、BWR-4 MarkⅠ)) ····· 3-136 xxxv 図 3.3.1.9-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TC、BWR-4 MarkⅠ)) ···················· 3-136 図 3.3.1.10-1 格納容器系圧力(圧力容器破損前のベント作動(S2C、BWR-4 MarkⅠ)) ··· 3-137 図 3.3.1.10-2 格納容器系温度(圧力容器破損前のベント作動(S2C、BWR-4 MarkⅠ)) ··· 3-137 図 3.3.1.10-3 格納容器系水位(圧力容器破損前のベント作動(S2C、BWR-4 MarkⅠ)) ··· 3-138 図 3.3.1.10-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(S2C、BWR-4 MarkⅠ)) ··················· 3-138 図 3.3.1.11-1 格納容器系圧力(圧力容器破損前のベント作動(AE、BWR-4 MarkⅠ)) ···· 3-139 図 3.3.1.11-2 格納容器系温度(圧力容器破損前のベント作動(AE、BWR-4 MarkⅠ)) ···· 3-139 図 3.3.1.11-3 格納容器系水位(圧力容器破損前のベント作動(AE、BWR-4 MarkⅠ)) ···· 3-140 図 3.3.1.11-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(AE、BWR-4 MarkⅠ)) ···················· 3-140 図 3.3.1.12-1 格納容器系圧力(圧力容器破損後のベント作動(AE、BWR-4 MarkⅠ)) ···· 3-141 図 3.3.1.12-2 格納容器系温度(圧力容器破損後のベント作動(AE、BWR-4 MarkⅠ)) ···· 3-141 図 3.3.1.12-3 格納容器系水位(圧力容器破損後のベント作動(AE、BWR-4 MarkⅠ)) ···· 3-142 図 3.3.1.12-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(AE、BWR-4 MarkⅠ)) ···················· 3-142 図 3.3.2.1-1 格納容器系圧力(圧力容器破損前の機器復旧(TQUV、BWR-4 MarkⅠ)) ····· 3-143 図 3.3.2.1-2 格納容器系温度(圧力容器破損前の機器復旧(TQUV、BWR-4 MarkⅠ)) ····· 3-143 図 3.3.2.1-3 格納容器系水位(圧力容器破損前の機器復旧(TQUV、BWR-4 MarkⅠ)) ····· 3-144 図 3.3.2.1-4 各放射性物質の環境放出量割合 (圧力容器破損前の機器復旧(TQUV、BWR-4 MarkⅠ)) ···················· 3-144 図 3.3.2.2-1 格納容器系圧力(圧力容器破損後の機器復旧(TQUV、BWR-4 MarkⅠ)) ····· 3-145 図 3.3.2.2-2 格納容器系温度(圧力容器破損後の機器復旧(TQUV、BWR-4 MarkⅠ)) ····· 3-145 図 3.3.2.2-3 格納容器系水位(圧力容器破損後の機器復旧(TQUV、BWR-4 MarkⅠ)) ····· 3-146 図 3.3.2.2-4 各放射性物質の環境放出量割合 (圧力容器破損後の機器復旧(TQUV、BWR-4 MarkⅠ)) ···················· 3-146 図 3.3.3.1-1 格納容器系圧力(圧力容器破損前の電源復旧(TB、BWR-4 MarkⅠ)) ······· 3-147 図 3.3.3.1-2 格納容器系温度(圧力容器破損前の電源復旧(TB、BWR-4 MarkⅠ)) ······· 3-147 図 3.3.3.1-3 格納容器系水位(圧力容器破損前の電源復旧(TB、BWR-4 MarkⅠ)) ······· 3-148 xxxvi 図 3.3.3.1-4 各放射性物質の環境放出量割合 (圧力容器破損前の電源復旧(TB、BWR-4 MarkⅠ)) ······················ 3-148 図 3.3.3.2-1 格納容器系圧力(圧力容器破損後の電源復旧(TB、BWR-4 MarkⅠ)) ······· 3-149 図 3.3.3.2-2 格納容器系温度(圧力容器破損後の電源復旧(TB、BWR-4 MarkⅠ)) ······· 3-149 図 3.3.3.2-3 格納容器系水位(圧力容器破損後の電源復旧(TB、BWR-4 MarkⅠ)) ······· 3-150 図 3.3.3.2-4 各放射性物質の環境放出量割合 (圧力容器破損後の電源復旧(TB、BWR-4 MarkⅠ)) ······················ 3-150 図 3.3.3.3-1 格納容器系圧力(圧力容器破損前の電源復旧(TBU、BWR-4 MarkⅠ)) ······ 3-151 図 3.3.3.3-2 格納容器系温度(圧力容器破損前の電源復旧(TBU、BWR-4 MarkⅠ)) ······ 3-151 図 3.3.3.3-3 格納容器系水位(圧力容器破損前の電源復旧(TBU、BWR-4 MarkⅠ)) ······ 3-152 図 3.3.3.3-4 各放射性物質の環境放出量割合 (圧力容器破損前の電源復旧(TBU、BWR-4 MarkⅠ)) ····················· 3-152 図 3.3.3.4-1 格納容器系圧力(圧力容器破損後の電源復旧(TBU、BWR-4 MarkⅠ)) ······ 3-153 図 3.3.3.4-2 格納容器系温度(圧力容器破損後の電源復旧(TBU、BWR-4 MarkⅠ)) ······ 3-153 図 3.3.3.4-3 格納容器系水位(圧力容器破損後の電源復旧(TBU、BWR-4 MarkⅠ)) ······ 3-154 図 3.3.3.4-4 各放射性物質の環境放出量割合 (圧力容器破損後の電源復旧(TBU、BWR-4 MarkⅠ)) ····················· 3-154 図 3.3.3.5-1 格納容器系圧力(圧力容器破損前の電源復旧(S2B、BWR-4 MarkⅠ)) ······ 3-155 図 3.3.3.5-2 格納容器系温度(圧力容器破損前の電源復旧(S2B、BWR-4 MarkⅠ)) ······ 3-155 図 3.3.3.5-3 格納容器系水位(圧力容器破損前の電源復旧(S2B、BWR-4 MarkⅠ)) ······ 3-156 図 3.3.3.5-4 各放射性物質の環境放出量割合 (圧力容器破損前の電源復旧(S2B、BWR-4 MarkⅠ)) ····················· 3-156 図 3.3.3.6-1 格納容器系圧力(圧力容器破損後の電源復旧(S2B、BWR-4 MarkⅠ)) ······ 3-157 図 3.3.3.6-2 格納容器系温度(圧力容器破損後の電源復旧(S2B、BWR-4 MarkⅠ)) ······ 3-157 図 3.3.3.6-3 格納容器系水位(圧力容器破損後の電源復旧(S2B、BWR-4 MarkⅠ)) ······ 3-158 図 3.3.3.6-4 各放射性物質の環境放出量割合 (圧力容器破損後の電源復旧(S2B、BWR-4 MarkⅠ)) ····················· 3-158 図 3.3.4.1-1 格納容器系圧力(CRD 注水(TQUV、BWR-4 MarkⅠ)) ····················· 3-159 図 3.3.4.1-2 格納容器系温度(CRD 注水(TQUV、BWR-4 MarkⅠ)) ····················· 3-159 図 3.3.4.1-3 格納容器系水位(CRD 注水(TQUV、BWR-4 MarkⅠ)) ····················· 3-160 xxxvii 図 3.3.4.1-4 各放射性物質の環境放出量割合(CRD 注水(TQUV、BWR-4 MarkⅠ)) ······· 3-160 図 3.3.4.2-1 格納容器系圧力(CUW 除熱あり/なし(TQUV、BWR-4 MarkⅠ)) ············ 3-161 図 3.3.4.2-2 格納容器系温度(CUW 除熱あり/なし(TQUV、BWR-4 MarkⅠ)) ············ 3-161 図 3.3.4.2-3 各放射性物質の環境放出量割合(CUW 除熱あり(TQUV、BWR-4 MarkⅠ)) ··· 3-162 図 3.3.4.2-4 各放射性物質の環境放出量割合(CUW 除熱なし(TQUV、BWR-4 MarkⅠ)) ··· 3-162 図 3.3.4.3-1 格納容器系圧力(圧力容器破損前 DW クーラあり/なし(TQUV、BWR-4 MarkⅠ)) ················································································ 3-163 図 3.3.4.3-2 格納容器系温度(圧力容器破損前 DW クーラあり/なし(TQUV、BWR-4 MarkⅠ)) ················································································ 3-163 図 3.3.4.3-3 各放射性物質の環境放出量割合 (圧力容器系破損前 DW クーラあり(TQUV、BWR-4 MarkⅠ)) ············· 3-164 図 3.3.4.3-4 各放射性物質の環境放出量割合 (圧力容器系破損前 DW クーラなし(TQUV、BWR-4 MarkⅠ)) ············· 3-164 図 3.3.4.4-1 格納容器系圧力(圧力容器破損後 DW クーラあり/なし(TQUV、BWR-4 MarkⅠ)) ················································································ 3-165 図 3.3.4.4-2 格納容器系温度(圧力容器破損後 DW クーラあり/なし(TQUV、BWR-4 MarkⅠ)) ················································································ 3-165 図 3.3.4.4-3 各放射性物質の環境放出量割合 (圧力容器系破損後 DW クーラあり(TQUV、BWR-4 MarkⅠ)) ············· 3-166 図 3.3.4.4-4 各放射性物質の環境放出量割合 (圧力容器系破損後 DW クーラなし(TQUV、BWR-4 MarkⅠ)) ············· 3-166 図 3.3.4.5-1 格納容器系圧力(CRD 注水(TQUX、BWR-4 MarkⅠ)) ····················· 3-167 図 3.3.4.5-2 格納容器系温度(CRD 注水(TQUX、BWR-4 MarkⅠ)) ····················· 3-167 図 3.3.4.5-3 格納容器系水位(CRD 注水(TQUX、BWR-4 MarkⅠ)) ····················· 3-168 図 3.3.4.5-4 各放射性物質の環境放出量割合(CRD 注水(TQUX、BWR-4 MarkⅠ)) ······· 3-168 図 3.3.4.6-1 格納容器系圧力(CUW 除熱あり/なし(TQUX、BWR-4 MarkⅠ)) ············ 3-169 図 3.3.4.6-2 格納容器系温度(CUW 除熱あり/なし(TQUX、BWR-4 MarkⅠ)) ············ 3-169 図 3.3.4.6-3 各放射性物質の環境放出量割合(CUW 除熱あり(TQUX、BWR-4 MarkⅠ)) ··· 3-170 図 3.3.4.6-4 各放射性物質の環境放出量割合(CUW 除熱なし(TQUX、BWR-4 MarkⅠ)) ··· 3-170 図 3.3.4.7-1 格納容器系圧力(圧力容器破損前 DW クーラあり/なし(TQUX、BWR-4 MarkⅠ)) xxxviii ················································································ 3-171 図 3.3.4.7-2 格納容器系温度(圧力容器破損前 DW クーラあり/なし(TQUX、BWR-4 MarkⅠ)) ················································································ 3-171 図 3.3.4.7-3 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラあり(TQUX、BWR-4 MarkⅠ)) ··············· 3-172 図 3.3.4.7-4 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラなし(TQUX、BWR-4 MarkⅠ)) ··············· 3-172 図 3.3.4.8-1 格納容器系圧力(圧力容器破損後 DW クーラあり/なし(TQUX、BWR-4 MarkⅠ)) ················································································ 3-173 図 3.3.4.8-2 格納容器系温度(圧力容器破損後 DW クーラあり/なし(TQUX、BWR-4 MarkⅠ)) ················································································ 3-173 図 3.3.4.8-3 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラあり(TQUX、BWR-4 MarkⅠ)) ··············· 3-174 図 3.3.4.8-4 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラなし(TQUX、BWR-4 MarkⅠ)) ··············· 3-174 図 3.3.4.9-1 格納容器系圧力(CRD 注水(AE、BWR-4 MarkⅠ)) ······················· 3-175 図 3.3.4.9-2 格納容器系温度(CRD 注水(AE、BWR-4 MarkⅠ)) ······················· 3-175 図 3.3.4.9-3 格納容器系水位(CRD 注水(AE、BWR-4 MarkⅠ)) ······················· 3-176 図 3.3.4.9-4 各放射性物質の環境放出量割合(CRD 注水(AE、BWR-4 MarkⅠ)) ········· 3-176 図 3.3.4.10-1 格納 容器系 圧力 (圧力 容器 破損 前 DW クーラ あり /なし(AE、 BWR-4 MarkⅠ)) ················································································ 3-177 図 3.3.4.10-2 格納 容器系 温度 (圧力 容器 破損 前 DW クーラ あり /なし(AE、 BWR-4 MarkⅠ)) ················································································ 3-177 図 3.3.4.10-3 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラあり(AE、BWR-4 MarkⅠ)) ················· 3-178 図 3.3.4.10-4 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラなし(AE、BWR-4 MarkⅠ)) ················· 3-178 図 3.3.4.11-1 格納 容器系 圧力 (圧力 容器 破損 後 DW クーラ あり /なし(AE、 BWR-4 MarkⅠ)) ················································································ 3-179 図 3.3.4.11-2 格納 容器系 温度 (圧力 容器 破損 後 DW クーラ あり /なし(AE、 BWR-4 MarkⅠ)) xxxix ················································································ 3-179 図 3.3.4.11-3 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラあり(AE、BWR-4 MarkⅠ)) ··················· 3-180 図 3.3.4.11-4 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラなし(AE、BWR-4 MarkⅠ)) ··················· 3-180 図 3.4.1-1 プラント内 FP 分布(高圧・低圧注水失敗(TQUV、BWR-4 MarkⅠ)) ·········· 3-188 図 3.4.1-2 プラント内 FP 分布 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-4 MarkⅠ)) ·············· 3-188 図 3.4.1-3 プラント内 FP 分布(高圧注水・減圧失敗(TQUX、BWR-4 MarkⅠ)) ·········· 3-189 図 3.4.1-4 プラント内 FP 分布(電源喪失(TB、BWR-4 MarkⅠ)) ······················ 3-189 図 3.4.1-5 プラント内 FP 分布(小 LOCA 時の電源喪失(S2B、BWR-4 MarkⅠ)) ·········· 3-190 図 3.4.1-6 プラント内 FP 分布(電源喪失(TBU、BWR-4 MarkⅠ)) ····················· 3-190 図 3.4.1-7 プラント内 FP 分布(崩壊熱除去失敗(TW、BWR-4 MarkⅠ)) ················ 3-191 図 3.4.1-8 プラント内 FP 分布(小 LOCA 時の崩壊熱除去失敗(S2W、BWR-4 MarkⅠ)) ···· 3-191 図 3.4.1-9 プラント内 FP 分布(原子炉未臨界確保失敗(TC、BWR-4 MarkⅠ)) ·········· 3-192 図 3.4.1-10 プラント内 FP 分布 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-4 MarkⅠ)) ·············· 3-192 図 3.4.1-11 プラント内 FP 分布(LOCA 時注水失敗(AE、BWR-4 MarkⅠ)) ·············· 3-193 図 3.4.1-12 プラント内 FP 分布(インターフェイス LOCA(V、BWR-4 MarkⅠ)) ········· 3-193 図 3.4.1-13 代表的な事故シーケンスの事故進展タイミング(BWR-4 MarkⅠ、AM なし) ··· 3-194 図 3.4.1-14 代表的な事故シーケンスのソースターム(BWR-4 MarkⅠ、AM なし) ········· 3-195 図 3.4.2-1 プラント内 FP 分布(圧力容器破損前のベント作動(TQUV、BWR-4 MarkⅠ)) ·· 3-196 図 3.4.2-2 プラント内 FP 分布(圧力容器破損後のベント作動(TQUV、BWR-4 MarkⅠ)) ·· 3-196 図 3.4.2-3 プラント内 FP 分布(圧力容器破損前のベント作動(TQUX、BWR-4 MarkⅠ)) ·· 3-197 図 3.4.2-4 プラント内 FP 分布(圧力容器破損後のベント作動(TQUX、BWR-4 MarkⅠ)) ·· 3-197 図 3.4.2-5 プラント内 FP 分布(圧力容器破損前のベント作動(TW、BWR-4 MarkⅠ)) ···· 3-198 図 3.4.2-6 プラント内 FP 分布(圧力容器破損前のベント作動(TC、BWR-4 MarkⅠ)) ···· 3-198 図 3.4.2-7 プラント内 FP 分布(圧力容器破損前のベント作動(S2C、BWR-4 MarkⅠ)) ··· 3-199 図 3.4.2-8 プラント内 FP 分布(圧力容器破損前のベント作動(AE、BWR-4 MarkⅠ)) ···· 3-199 図 3.4.2-9 プラント内 FP 分布(圧力容器破損後のベント作動(AE、BWR-4 MarkⅠ)) ···· 3-200 xl 図 3.4.2-10 プラント内 FP 分布 (圧力容器破損前のベント作動(S2QUV、BWR-4 MarkⅠ)) ················· 3-200 図 3.4.2-11 プラント内 FP 分布 (圧力容器破損後のベント作動(S2QUV、BWR-4 MarkⅠ)) ················· 3-201 図 3.4.2-12 プラント内 FP 分布(圧力容器破損前のベント作動(S2W、BWR-4 MarkⅠ)) ·· 3-201 図 3.4.2-13 プラント内 FP 分布(圧力容器破損前の機器復旧(TQUV、BWR-4 MarkⅠ)) ··· 3-202 図 3.4.2-14 プラント内 FP 分布(圧力容器破損後の機器復旧(TQUV、BWR-4 MarkⅠ)) ··· 3-202 図 3.4.2-15 プラント内 FP 分布(圧力容器破損前の電源復旧(TB、BWR-4 MarkⅠ)) ····· 3-203 図 3.4.2-16 プラント内 FP 分布(圧力容器破損後の電源復旧(TB、BWR-4 MarkⅠ)) ····· 3-203 図 3.4.2-17 プラント内 FP 分布(圧力容器破損前の電源復旧(TBU、BWR-4 MarkⅠ)) ···· 3-204 図 3.4.2-18 プラント内 FP 分布(圧力容器破損後の電源復旧(TBU、BWR-4 MarkⅠ)) ···· 3-204 図 3.4.2-19 プラント内 FP 分布(圧力容器破損前の電源復旧(S2B、BWR-4 MarkⅠ)) ···· 3-205 図 3.4.2-20 プラント内 FP 分布(圧力容器破損後の電源復旧(S2B、BWR-4 MarkⅠ)) ···· 3-205 図 3.4.2-21 プラント内 FP 分布(CRD 注水(TQUV、BWR-4 MarkⅠ)) ··················· 3-206 図 3.4.2-22 プラント内 FP 分布(CUW 除熱あり(TQUV、BWR-4 MarkⅠ)) ··············· 3-206 図 3.4.2-23 プラント内 FP 分布(CUW 除熱なし(TQUV、BWR-4 MarkⅠ)) ··············· 3-207 図 3.4.2-24 プラント内 FP 分布(圧力容器破損前 DW クーラ(TQUV、BWR-4 MarkⅠ)) ···· 3-207 図 3.4.2-25 プラント内 FP 分布(圧力容器破損後 DW クーラ(TQUV、BWR-4 MarkⅠ)) ···· 3-208 図 3.4.2-26 プラント内 FP 分布(CRD 注水(TQUX、BWR-4 MarkⅠ)) ··················· 3-208 図 3.4.2-27 プラント内 FP 分布(CUW 除熱あり(TQUX、BWR-4 MarkⅠ)) ··············· 3-209 図 3.4.2-28 プラント内 FP 分布(CUW 除熱なし(TQUX、BWR-4 MarkⅠ)) ··············· 3-209 図 3.4.2-29 プラント内 FP 分布(圧力容器破損前 DW クーラ(TQUX、BWR-4 MarkⅠ)) ···· 3-210 図 3.4.2-30 プラント内 FP 分布(圧力容器破損後 DW クーラ(TQUX、BWR-4 MarkⅠ)) ···· 3-210 図 3.4.2-31 プラント内 FP 分布(CRD 注水(AE、BWR-4 MarkⅠ)) ····················· 3-211 図 3.4.2-32 プラント内 FP 分布(圧力容器破損前 DW クーラ(AE、BWR-4 MarkⅠ)) ······ 3-211 図 3.4.2-33 プラント内 FP 分布(圧力容器破損後 DW クーラ(AE、BWR-4 MarkⅠ)) ······ 3-212 図 3.4.2-34 代表的な事故シーケンスの事故進展タイミング(BWR-4 MarkⅠ、AM あり) ··· 3-213 図 3.4.2-35 代表的な事故シーケンスのソースターム(BWR-4 MarkⅠ、AM あり) ········· 3-214 図 4.1-1 BWR-5 Mark II 型原子炉格納施設概要 ····································· 4-5 図 4.1-2 BWR-5 Mark II 型原子炉施設のボリューム分割と流路 ······················· 4-6 xli 図 4.1-3 本解析で用いた炉心部のセル分割 ········································· 4-7 図 4.1-4 BWR-5 の炉心セルのモデル ·············································· 4-8 図 4.1-5 BWR-5 Mark II 型原子炉施設の非常用炉心冷却系系統概略図 ················· 4-9 図 4.1-6 BWR-5 Mark II 型原子炉施設のECCS作動水位 ··························· 4-10 図 4.2.1-1 原子炉冷却系水位(高圧・低圧注水失敗(TQUV、BWR-5 Mark II)) ·········· 4-36 図 4.2.1-2 炉心最高温度(高圧・低圧注水失敗(TQUV、BWR-5 Mark II)) ·············· 4-36 図 4.2.1-3 原子炉冷却系圧力(高圧・低圧注水失敗(TQUV、BWR-5 Mark II)) ·········· 4-37 図 4.2.1-4 格納容器系圧力(高圧・低圧注水失敗(TQUV、BWR-5 Mark II)) ············ 4-37 図 4.2.1-5 格納容器系温度(高圧・低圧注水失敗(TQUV、BWR-5 Mark II)) ············ 4-38 図 4.2.1-6 格納容器系水位(高圧・低圧注水失敗(TQUV、BWR-5 Mark II)) ············ 4-38 図 4.2.1-7 サプレッション・プールの水温 (高圧・低圧注水失敗(TQUV、BWR-5 Mark II)) ·························· 4-39 図 4.2.1-8 各放射性物質の環境放出量割合 (高圧・低圧注水失敗(TQUV、BWR-5 Mark II)) ························· 4-39 図 4.2.2-1 原子炉冷却系水位 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-5 Mark II)) ············· 4-40 図 4.2.2-2 格納容器系圧力 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-5 Mark II)) ············· 4-40 図 4.2.2-3 格納容器系温度 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-5 Mark II)) ············· 4-41 図 4.2.2-4 各放射性物質の環境放出量割合 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-5 Mark II)) ············· 4-41 図 4.2.3-1 原子炉冷却系水位(高圧注水・減圧失敗(TQUX、BWR-5 Mark II)) ·········· 4-42 図 4.2.3-2 格納容器系圧力(高圧注水・減圧失敗(TQUX、BWR-5 Mark II)) ············ 4-42 図 4.2.3-3 格納容器系温度(高圧注水・減圧失敗(TQUX、BWR-5 Mark II)) ············ 4-43 図 4.2.3-4 各放射性物質の環境放出量割合 (高圧注水・減圧失敗(TQUX、BWR-5 Mark II)) ························· 4-43 図 4.2.4-1 原子炉冷却系水位(電源喪失(TB、BWR-5 Mark II)) ······················ 4-44 図 4.2.4-2 炉心最高温度(電源喪失(TB、BWR-5 Mark II)) ·························· 4-44 図 4.2.4-3 原子炉冷却系圧力(電源喪失(TB、BWR-5 Mark II)) ······················ 4-45 xlii 図 4.2.4-4 格納容器系圧力(電源喪失(TB、BWR-5 Mark II)) ························ 4-45 図 4.2.4-5 格納容器系温度(電源喪失(TB、BWR-5 Mark II)) ························ 4-46 図 4.2.4-6 格納容器系水位(電源喪失(TB、BWR-5 Mark II)) ························ 4-46 図 4.2.4-7 サプレッション・プールの水温(電源喪失(TB、BWR-5 Mark II)) ·········· 4-47 図 4.2.4-8 各放射性物質の環境放出量割合(電源喪失(TB、BWR-5 Mark II)) ·········· 4-47 図 4.2.5-1 原子炉冷却系水位(小 LOCA 時の電源喪失(S2B、BWR-5 Mark II)) ·········· 4-48 図 4.2.5-2 格納容器系圧力(小 LOCA 時の電源喪失(S2B、BWR-5 Mark II)) ············ 4-48 図 4.2.5-3 格納容器系温度(小 LOCA 時の電源喪失(S2B、BWR-5 Mark II)) ············ 4-49 図 4.2.5-4 各放射性物質の環境放出量割合 (小 LOCA 時の電源喪失(S2B、BWR-5 Mark II)) ························· 4-49 図 4.2.6-1 原子炉冷却系水位(電源喪失(TBU、BWR-5 Mark II)) ····················· 4-50 図 4.2.6-2 格納容器系圧力(電源喪失(TBU、BWR-5 Mark II)) ······················· 4-50 図 4.2.6-3 格納容器系温度(電源喪失(TBU、BWR-5 Mark II)) ······················· 4-51 図 4.2.6-4 各放射性物質の環境放出量割合(電源喪失(TBU、BWR-5 Mark II)) ········· 4-51 図 4.2.7-1 原子炉冷却系水位(崩壊熱除去失敗(TW、BWR-5 Mark II)) ················ 4-52 図 4.2.7-2 炉心最高温度(崩壊熱除去失敗(TW、BWR-5 Mark II)) ···················· 4-52 図 4.2.7-3 原子炉冷却系圧力(崩壊熱除去失敗(TW、BWR-5 Mark II)) ················ 4-53 図 4.2.7-4 格納容器系圧力(崩壊熱除去失敗(TW、BWR-5 Mark II)) ·················· 4-53 図 4.2.7-5 格納容器系温度(崩壊熱除去失敗(TW、BWR-5 Mark II)) ·················· 4-54 図 4.2.7-6 格納容器系水位(崩壊熱除去失敗(TW、BWR-5 Mark II)) ·················· 4-54 図 4.2.7-7 サプレッション・プールの水温(崩壊熱除去失敗(TW、BWR-5 Mark II)) ···· 4-55 図 4.2.7-8 各放射性物質の環境放出量割合(崩壊熱除去失敗(TW、BWR-5 Mark II)) ···· 4-55 図 4.2.8-1 原子炉冷却系水位(小 LOCA 時の崩壊熱除去失敗(S2W、BWR-5 Mark II)) ···· 4-56 図 4.2.8-2 格納容器系圧力(小 LOCA 時の崩壊熱除去失敗(S2W、BWR-5 Mark II)) ······ 4-56 図 4.2.8-3 格納容器系温度(小 LOCA 時の崩壊熱除去失敗(S2W、BWR-5 Mark II)) ······ 4-57 図 4.2.8-4 各放射性物質の環境放出量割合 (小 LOCA 時の崩壊熱除去失敗(S2W、BWR-5 Mark II)) ··················· 4-57 図 4.2.9-1 原子炉冷却系水位(原子炉未臨界確保失敗(TC、BWR-5 Mark II)) ·········· 4-58 図 4.2.9-2 炉心最高温度(原子炉未臨界確保失敗(TC、BWR-5 Mark II)) ·············· 4-58 図 4.2.9-3 原子炉冷却系圧力(原子炉未臨界確保失敗(TC、BWR-5 Mark II)) ·········· 4-59 xliii 図 4.2.9-4 格納容器系圧力(原子炉未臨界確保失敗(TC、BWR-5 Mark II)) ············ 4-59 図 4.2.9-5 格納容器系温度(原子炉未臨界確保失敗(TC、BWR-5 Mark II)) ············ 4-60 図 4.2.9-6 格納容器系水位(原子炉未臨界確保失敗(TC、BWR-5 Mark II)) ············ 4-60 図 4.2.9-7 サプレッション・プールの水温 (原子炉未臨界確保失敗(TC、BWR-5 Mark II)) ·························· 4-61 図 4.2.9-8 各放射性物質の環境放出量割合 (原子炉未臨界確保失敗(TC、BWR-5 Mark II)) ························· 4-61 図 4.2.10-1 原子炉冷却系水位 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-5 Mark II)) ············· 4-62 図 4.2.10-2 格納容器系圧力 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-5 Mark II)) ············· 4-62 図 4.2.10-3 格納容器系温度 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-5 Mark II)) ············· 4-63 図 4.2.10-4 各放射性物質の環境放出量割合 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-5 Mark II)) ············· 4-63 図 4.2.11-1 原子炉冷却系水位(LOCA 時注水失敗(AE、BWR-5 Mark II)) ·············· 4-64 図 4.2.11-2 炉心最高温度(LOCA 時注水失敗(AE、BWR-5 Mark II)) ·················· 4-64 図 4.2.11-3 原子炉冷却系圧力(LOCA 時注水失敗(AE、BWR-5 Mark II)) ·············· 4-65 図 4.2.11-4 格納容器系圧力(LOCA 時注水失敗(AE、BWR-5 Mark II)) ················ 4-65 図 4.2.11-5 格納容器系温度(LOCA 時注水失敗(AE、BWR-5 Mark II)) ················ 4-66 図 4.2.11-6 格納容器系水位(LOCA 時注水失敗(AE、BWR-5 Mark II)) ················ 4-66 図 4.2.11-7 サプレッション・プールの水温(LOCA 時注水失敗(AE、BWR-5 Mark II)) ·· 4-67 図 4.2.11-8 各放射性物質の環境放出量割合(LOCA 時注水失敗(AE、BWR-5 Mark II)) ·· 4-67 図 4.2.12-1 原子炉冷却系水位(インターフェイス LOCA(V、BWR-5 Mark II)) ········· 4-68 図 4.2.12-2 炉心最高温度(インターフェイス LOCA(V、BWR-5 Mark II)) ············· 4-68 図 4.2.12-3 原子炉冷却系圧力(インターフェイス LOCA(V、BWR-5 Mark II)) ········· 4-69 図 4.2.12-4 格納容器系圧力(インターフェイス LOCA(V、BWR-5 Mark II)) ··········· 4-69 図 4.2.12-5 格納容器系温度(インターフェイス LOCA(V、BWR-5 Mark II)) ··········· 4-70 図 4.2.12-6 格納容器系水位(インターフェイス LOCA(V、BWR-5 Mark II)) ··········· 4-70 図 4.2.12-7 サプレッション・プールの水温 xliv (インターフェイス LOCA(V、BWR-5 Mark II)) ··························· 4-71 図 4.2.12-8 各放射性物質の環境放出量割合 (インターフェイス LOCA(V、BWR-5 Mark II)) ·························· 4-71 図 4.3.1.1-1 格納容器系圧力(圧力容器破損前のベント作動(TQUV、BWR-5 Mark II)) ·· 4-120 図 4.3.1.1-2 格納容器系温度(圧力容器破損前のベント作動(TQUV、BWR-5 Mark II)) ·· 4-120 図 4.3.1.1-3 格納容器系水位(圧力容器破損前のベント作動(TQUV、BWR-5 Mark II)) ·· 4-121 図 4.3.1.1-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TQUV、BWR-5 Mark II)) ················· 4-121 図 4.3.1.2-1 格納容器系圧力(圧力容器破損後のベント作動(TQUV、BWR-5 Mark II)) ·· 4-122 図 4.3.1.2-2 格納容器系温度(圧力容器破損後のベント作動(TQUV、BWR-5 Mark II)) ·· 4-122 図 4.3.1.2-3 格納容器系水位(圧力容器破損後のベント作動(TQUV、BWR-5 Mark II)) ·· 4-123 図 4.3.1.2-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(TQUV、BWR-5 Mark II)) ················· 4-123 図 4.3.1.3-1 格納容器系圧力(圧力容器破損前のベント作動(S2QUV、BWR-5 Mark II)) · 4-124 図 4.3.1.3-2 格納容器系温度(圧力容器破損前のベント作動(S2QUV、BWR-5 Mark II)) · 4-124 図 4.3.1.3-3 格納容器系水位(圧力容器破損前のベント作動(S2QUV、BWR-5 Mark II)) · 4-125 図 4.3.1.3-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(S2QUV、BWR-5 Mark II)) ················ 4-125 図 4.3.1.4-1 格納容器系圧力(圧力容器破損後のベント作動(S2QUV、BWR-5 Mark II)) · 4-126 図 4.3.1.4-2 格納容器系温度(圧力容器破損後のベント作動(S2QUV、BWR-5 Mark II)) · 4-126 図 4.3.1.4-3 格納容器系水位(圧力容器破損後のベント作動(S2QUV、BWR-5 Mark II)) · 4-127 図 4.3.1.4-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(S2QUV、BWR-5 Mark II)) ················ 4-127 図 4.3.1.5-1 格納容器系圧力(圧力容器破損前のベント作動(TQUX、BWR-5 Mark II)) ·· 4-128 図 4.3.1.5-2 格納容器系温度(圧力容器破損前のベント作動(TQUX、BWR-5 Mark II)) ·· 4-128 図 4.3.1.5-3 格納容器系水位(圧力容器破損前のベント作動(TQUX、BWR-5 Mark II)) ·· 4-129 図 4.3.1.5-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TQUX、BWR-5 Mark II)) ················· 4-129 図 4.3.1.6-1 格納容器系圧力(圧力容器破損後のベント作動(TQUX、BWR-5 Mark II)) ·· 4-130 図 4.3.1.6-2 格納容器系温度(圧力容器破損後のベント作動(TQUX、BWR-5 Mark II)) ·· 4-130 xlv 図 4.3.1.6-3 格納容器系水位(圧力容器破損後のベント作動(TQUX、BWR-5 Mark II)) ·· 4-131 図 4.3.1.6-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(TQUX、BWR-5 Mark II)) ················· 4-131 図 4.3.1.7-1 格納容器系圧力(圧力容器破損前のベント作動(TW、BWR-5 Mark II)) ···· 4-132 図 4.3.1.7-2 格納容器系温度(圧力容器破損前のベント作動(TW、BWR-5 Mark II)) ···· 4-132 図 4.3.1.7-3 格納容器系水位(圧力容器破損前のベント作動(TW、BWR-5 Mark II)) ···· 4-133 図 4.3.1.7-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TW、BWR-5 Mark II)) ··················· 4-133 図 4.3.1.8-1 格納容器系圧力(圧力容器破損前のベント作動(S2W、BWR-5 Mark II)) ··· 4-134 図 4.3.1.8-2 格納容器系温度(圧力容器破損前のベント作動(S2W、BWR-5 Mark II)) ··· 4-134 図 4.3.1.8-3 格納容器系水位(圧力容器破損前のベント作動(S2W、BWR-5 Mark II)) ··· 4-135 図 4.3.1.8-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(S2W、BWR-5 Mark II)) ·················· 4-135 図 4.3.1.9-1 格納容器系圧力(圧力容器破損前のベント作動(TC、BWR-5 Mark II)) ···· 4-136 図 4.3.1.9-2 格納容器系温度(圧力容器破損前のベント作動(TC、BWR-5 Mark II)) ···· 4-136 図 4.3.1.9-3 格納容器系水位(圧力容器破損前のベント作動(TC、BWR-5 Mark II)) ···· 4-137 図 4.3.1.9-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TC、BWR-5 Mark II)) ··················· 4-137 図 4.3.1.10-1 格納容器系圧力(圧力容器破損前のベント作動(S2C、BWR-5 Mark II)) ·· 4-138 図 4.3.1.10-2 格納容器系温度(圧力容器破損前のベント作動(S2C、BWR-5 Mark II)) ·· 4-138 図 4.3.1.10-3 格納容器系水位(圧力容器破損前のベント作動(S2C、BWR-5 Mark II)) ·· 4-139 図 4.3.1.10-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(S2C、BWR-5 Mark II)) ·················· 4-139 図 4.3.1.11-1 格納容器系圧力(圧力容器破損前のベント作動(AE、BWR-5 Mark II)) ··· 4-140 図 4.3.1.11-2 格納容器系温度(圧力容器破損前のベント作動(AE、BWR-5 Mark II)) ··· 4-140 図 4.3.1.11-3 格納容器系水位(圧力容器破損前のベント作動(AE、BWR-5 Mark II)) ··· 4-141 図 4.3.1.11-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(AE、BWR-5 Mark II)) ··················· 4-141 図 4.3.1.12-1 格納容器系圧力(圧力容器破損後のベント作動(AE、BWR-5 Mark II)) ··· 4-142 図 4.3.1.12-2 格納容器系温度(圧力容器破損後のベント作動(AE、BWR-5 Mark II)) ··· 4-142 xlvi 図 4.3.1.12-3 格納容器系水位(圧力容器破損後のベント作動(AE、BWR-5 Mark II)) ··· 4-143 図 4.3.1.12-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(AE、BWR-5 Mark II)) ··················· 4-143 図 4.3.2.1-1 格納容器系圧力(圧力容器破損前の機器復旧(TQUV、BWR-5 Mark II)) ···· 4-144 図 4.3.2.1-2 格納容器系温度(圧力容器破損前の機器復旧(TQUV、BWR-5 Mark II)) ···· 4-144 図 4.3.2.1-3 格納容器系水位(圧力容器破損前の機器復旧(TQUV、BWR-5 Mark II)) ···· 4-145 図 4.3.2.1-4 各放射性物質の環境放出量割合 (圧力容器破損前の機器復旧(TQUV、BWR-5 Mark II)) ··················· 4-145 図 4.3.2.2-1 格納容器系圧力(圧力容器破損後の機器復旧(TQUV、BWR-5 Mark II)) ···· 4-146 図 4.3.2.2-2 格納容器系温度(圧力容器破損後の機器復旧(TQUV、BWR-5 Mark II)) ···· 4-146 図 4.3.2.2-3 格納容器系水位(圧力容器破損後の機器復旧(TQUV、BWR-5 Mark II)) ···· 4-147 図 4.3.2.2-4 各放射性物質の環境放出量割合 (圧力容器破損後の機器復旧(TQUV、BWR-5 Mark II)) ··················· 4-147 図 4.3.3.1-1 格納容器系圧力(圧力容器破損前の電源復旧(TB、BWR-5 Mark II)) ······ 4-148 図 4.3.3.1-2 格納容器系温度(圧力容器破損前の電源復旧(TB、BWR-5 Mark II)) ······ 4-148 図 4.3.3.1-3 格納容器系水位(圧力容器破損前の電源復旧(TB、BWR-5 Mark II)) ······ 4-149 図 4.3.3.1-4 各放射性物質の環境放出量割合 (圧力容器破損前の電源復旧(TB、BWR-5 Mark II)) ····················· 4-149 図 4.3.3.2-1 格納容器系圧力(圧力容器破損後の電源復旧(TB、BWR-5 Mark II)) ······ 4-150 図 4.3.3.2-2 格納容器系温度(圧力容器破損後の電源復旧(TB、BWR-5 Mark II)) ······ 4-150 図 4.3.3.2-3 格納容器系水位(圧力容器破損後の電源復旧(TB、BWR-5 Mark II)) ······ 4-151 図 4.3.3.2-4 各放射性物質の環境放出量割合 (圧力容器破損後の電源復旧(TB、BWR-5 Mark II)) ····················· 4-151 図 4.3.3.3-1 格納容器系圧力(圧力容器破損前の電源復旧(TBU、BWR-5 Mark II)) ····· 4-152 図 4.3.3.3-2 格納容器系温度(圧力容器破損前の電源復旧(TBU、BWR-5 Mark II)) ····· 4-152 図 4.3.3.3-3 格納容器系水位(圧力容器破損前の電源復旧(TBU、BWR-5 Mark II)) ····· 4-153 図 4.3.3.3-4 各放射性物質の環境放出量割合 (圧力容器破損前の電源復旧(TBU、BWR-5 Mark II)) ···················· 4-153 図 4.3.3.4-1 格納容器系圧力(圧力容器破損後の電源復旧(TBU、BWR-5 Mark II)) ····· 4-154 図 4.3.3.4-2 格納容器系温度(圧力容器破損後の電源復旧(TBU、BWR-5 Mark II)) ····· 4-154 xlvii 図 4.3.3.4-3 格納容器系水位(圧力容器破損後の電源復旧(TBU、BWR-5 Mark II)) ····· 4-155 図 4.3.3.4-4 各放射性物質の環境放出量割合 (圧力容器破損後の電源復旧(TBU、BWR-5 Mark II)) ···················· 4-155 図 4.3.3.5-1 格納容器系圧力(圧力容器破損前の電源復旧(S2B、BWR-5 Mark II)) ····· 4-156 図 4.3.3.5-2 格納容器系温度(圧力容器破損前の電源復旧(S2B、BWR-5 Mark II)) ····· 4-156 図 4.3.3.5-3 格納容器系水位(圧力容器破損前の電源復旧(S2B、BWR-5 Mark II)) ····· 4-157 図 4.3.3.5-4 各放射性物質の環境放出量割合 (圧力容器破損前の電源復旧(S2B、BWR-5 Mark II)) ···················· 4-157 図 4.3.3.6-1 格納容器系圧力(圧力容器破損後の電源復旧(S2B、BWR-5 Mark II)) ····· 4-158 図 4.3.3.6-2 格納容器系温度(圧力容器破損後の電源復旧(S2B、BWR-5 Mark II)) ····· 4-158 図 4.3.3.6-3 格納容器系水位(圧力容器破損後の電源復旧(S2B、BWR-5 Mark II)) ····· 4-159 図 4.3.3.6-4 各放射性物質の環境放出量割合 (圧力容器破損後の電源復旧(S2B、BWR-5 Mark II)) ···················· 4-159 図 4.3.4.1-1 格納容器系圧力(CRD 注水(TQUV、BWR-5 Mark II)) ···················· 4-160 図 4.3.4.1-2 格納容器系温度(CRD 注水(TQUV、BWR-5 Mark II)) ···················· 4-160 図 4.3.4.1-3 格納容器系水位(CRD 注水(TQUV、BWR-5 Mark II)) ···················· 4-161 図 4.3.4.1-4 各放射性物質の環境放出量割合(CRD 注水(TQUV、BWR-5 Mark II)) ······ 4-161 図 4.3.4.2-1 格納容器系圧力(CUW 除熱あり/なし(TQUV、BWR-5 Mark II)) ··········· 4-162 図 4.3.4.2-2 格納容器温度(CUW 除熱あり/なし(TQUV、BWR-5 Mark II)) ············· 4-162 図 4.3.4.2-3 各放射性物質の環境放出量割合(CUW 除熱あり(TQUV、BWR-5 Mark II)) ·· 4-163 図 4.3.4.2-4 各放射性物質の環境放出量割合(CUW 除熱なし(TQUV、BWR-5 Mark II)) ·· 4-163 図 4.3.4.3-1 格納容器系圧力(圧力容器破損前 DW クーラあり/なし(TQUV、BWR-5 Mark II)) ················································································ 4-164 図 4.3.4.3-2 格 納 容 器 温度 ( 圧 力 容器 破 損 前 DW ク ー ラ あり /な し(TQUV、 BWR-5 Mark II)) ················································································ 4-164 図 4.3.4.3-3 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラあり(TQUV、BWR-5 Mark II)) ·············· 4-165 図 4.3.4.3-4 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラなし(TQUV、BWR-5 Mark II)) ·············· 4-165 図 4.3.4.4-1 格納容器系圧力(圧力容器破損後 DW クーラあり/なし(TQUV、BWR-5 Mark II)) xlviii ················································································ 4-166 図 4.3.4.4-2 格 納 容 器 温度 ( 圧 力 容器 破 損 後 DW ク ー ラ あり /な し(TQUV、 BWR-5 Mark II)) ················································································ 4-166 図 4.3.4.4-3 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラあり(TQUV、BWR-5 Mark II)) ·············· 4-167 図 4.3.4.4-4 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラなし(TQUV、BWR-5 Mark II)) ·············· 4-167 図 4.3.4.5-1 格納容器系圧力(CRD 注水(TQUX、BWR-5 Mark II)) ···················· 4-168 図 4.3.4.5-2 格納容器系温度(CRD 注水(TQUX、BWR-5 Mark II)) ···················· 4-168 図 4.3.4.5-3 格納容器系水位(CRD 注水(TQUX、BWR-5 Mark II)) ···················· 4-169 図 4.3.4.5-4 各放射性物質の環境放出量割合(CRD 注水(TQUX、BWR-5 Mark II)) ······ 4-169 図 4.3.4.6-1 格納容器系圧力(CUW 除熱あり/なし(TQUX、BWR-5 Mark II)) ··········· 4-170 図 4.3.4.6-2 格納容器温度(CUW 除熱あり/なし(TQUX、BWR-5 Mark II)) ············· 4-170 図 4.3.4.6-3 各放射性物質の環境放出量割合(CUW 除熱あり(TQUX、BWR-5 Mark II)) ·· 4-171 図 4.3.4.6-4 各放射性物質の環境放出量割合(CUW 除熱なし(TQUX、BWR-5 Mark II)) ·· 4-171 図 4.3.4.7-1 格納容器系圧力(圧力容器破損前 DW クーラあり/なし(TQUX、BWR-5 Mark II)) ················································································ 4-172 図 4.3.4.7-2 格 納 容 器 温度 ( 圧 力 容器 破 損 前 DW ク ー ラ あり /な し(TQUX、 BWR-5 Mark II)) ················································································ 4-172 図 4.3.4.7-3 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラあり(TQUX、BWR-5 Mark II)) ·············· 4-173 図 4.3.4.7-4 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラなし(TQUX、BWR-5 Mark II)) ·············· 4-173 図 4.3.4.8-1 格納容器系圧力(圧力容器破損後 DW クーラあり/なし(TQUX、BWR-5 Mark II)) ················································································ 4-174 図 4.3.4.8-2 格 納 容 器 温度 ( 圧 力 容器 破 損 後 DW ク ー ラ あり /な し(TQUX、 BWR-5 Mark II)) ················································································ 4-174 図 4.3.4.8-3 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラあり(TQUX、BWR-5 Mark II)) ·············· 4-175 図 4.3.4.8-4 各放射性物質の環境放出量割合 xlix (圧力容器破損後 DW クーラなし(TQUX、BWR-5 Mark II)) ·············· 4-175 図 4.3.4.9-1 格納容器系圧力(CRD 注水(AE、BWR-5 Mark II)) ······················ 4-176 図 4.3.4.9-2 格納容器系温度(CRD 注水(AE、BWR-5 Mark II)) ······················ 4-176 図 4.3.4.9-3 格納容器系水位(CRD 注水(AE、BWR-5 Mark II)) ······················ 4-177 図 4.3.4.9-4 各放射性物質の環境放出量割合(CRD 注水(AE、BWR-5 Mark II)) ········ 4-177 図 4.3.4.10-1 格納容器系圧力(圧力容器破損前 DW クーラあり/なし(AE、BWR-5 Mark II)) ················································································ 4-178 図 4.3.4.10-2 格 納 容 器 温 度 ( 圧 力 容 器 破 損 前 DW ク ー ラ あ り /な し (AE、 BWR-5 Mark II)) ················································································ 4-178 図 4.3.4.10-3 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラあり(AE、BWR-5 Mark II)) ················ 4-179 図 4.3.4.10-4 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラなし(AE、BWR-5 Mark II)) ················ 4-179 図 4.3.4.11-1 格納容器系圧力(圧力容器破損後 DW クーラあり/なし(AE、BWR-5 Mark II)) ················································································ 4-180 図 4.3.4.11-2 格 納 容 器 温 度 ( 圧 力 容 器 破 損 後 DW ク ー ラ あ り /な し (AE、 BWR-5 Mark II)) ················································································ 4-180 図 4.3.4.11-3 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラあり(AE、BWR-5 Mark II)) ·················· 4-181 図 4.3.4.11-4 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラなし(AE、BWR-5 Mark II)) ·················· 4-181 図 4.4.1-1 プラント内 FP 分布(高圧・低圧注水失敗(TQUV、BWR-5 Mark II)) ········· 4-189 図 4.4.1-2 プラント内 FP 分布 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、BWR-5 Mark II)) ············· 4-189 図 4.4.1-3 プラント内 FP 分布(高圧注水・減圧失敗(TQUX、BWR-5 Mark II)) ········· 4-190 図 4.4.1-4 プラント内 FP 分布(電源喪失(TB、BWR-5 Mark II)) ····················· 4-190 図 4.4.1-5 プラント内 FP 分布(小 LOCA 時の電源喪失(S2B、BWR-5 Mark II)) ········· 4-191 図 4.4.1-6 プラント内 FP 分布(電源喪失(TBU、BWR-5 Mark II)) ···················· 4-191 図 4.4.1-7 プラント内 FP 分布(崩壊熱除去失敗(TW、BWR-5 Mark II)) ··············· 4-192 図 4.4.1-8 プラント内 FP 分布(小 LOCA 時の崩壊熱除去失敗(S2W、BWR-5 Mark II)) ··· 4-192 l 図 4.4.1-9 図 4.4.1-10 プラント内 FP 分布(原子炉未臨界確保失敗(TC、BWR-5 Mark II)) ········· 4-193 プラント内 FP 分布 (小 LOCA 時の原子炉未臨界確保失敗(S2C、BWR-5 Mark II)) ············· 4-193 図 4.4.1-11 プラント内 FP 分布(LOCA 時注水失敗(AE、BWR-5 Mark II)) ············· 4-194 図 4.4.1-12 プラント内 FP 分布(インターフェイス LOCA(V、BWR-5 Mark II)) ········ 4-194 図 4.4.1-13 代表的な事故シーケンスの事故進展タイミング(BWR-5 Mark II、AM なし) ·· 4-195 図 4.4.1-14 代表的な事故シーケンスのソースターム(BWR-5 Mark II、AM なし) ········ 4-196 図 4.4.2-1 プラント内 FP 分布(圧力容器破損前のベント作動(TQUV、BWR-5 Mark II)) · 4-197 図 4.4.2-2 プラント内 FP 分布(圧力容器破損後のベント作動(TQUV、BWR-5 Mark II)) · 4-197 図 4.4.2-3 プラント内 FP 分布(圧力容器破損前のベント作動(TQUX、BWR-5 Mark II)) · 4-198 図 4.4.2-4 プラント内 FP 分布(圧力容器破損後のベント作動(TQUX、BWR-5 Mark II)) · 4-198 図 4.4.2-5 プラント内 FP 分布(圧力容器破損前のベント作動(TW、BWR-5 Mark II)) ··· 4-199 図 4.4.2-6 プラント内 FP 分布(圧力容器破損前のベント作動(TC、BWR-5 Mark II)) ··· 4-199 図 4.4.2-7 プラント内 FP 分布(圧力容器破損前のベント作動(S2C、BWR-5 Mark II)) ·· 4-200 図 4.4.2-8 プラント内 FP 分布(圧力容器破損前のベント作動(AE、BWR-5 Mark II)) ··· 4-200 図 4.4.2-9 プラント内 FP 分布(圧力容器破損後のベント作動(AE、BWR-5 Mark II)) ··· 4-201 図 4.4.2-10 プラント内 FP 分布 (圧力容器破損前のベント作動(S2QUV、BWR-5 Mark II)) ················ 4-201 図 4.4.2-11 プラント内 FP 分布 (圧力容器破損後のベント作動(S2QUV、BWR-5 Mark II)) ················ 4-202 図 4.4.2-12 プラント内 FP 分布(圧力容器破損前のベント作動(S2W、BWR-5 Mark II)) · 4-202 図 4.4.2-13 プラント内 FP 分布(圧力容器破損前の機器復旧(TQUV、BWR-5 Mark II)) ·· 4-203 図 4.4.2-14 プラント内 FP 分布(圧力容器破損後の機器復旧(TQUV、BWR-5 Mark II)) ·· 4-203 図 4.4.2-15 プラント内 FP 分布(圧力容器破損前の電源復旧(TB、BWR-5 Mark II)) ···· 4-204 図 4.4.2-16 プラント内 FP 分布(圧力容器破損後の電源復旧(TB、BWR-5 Mark II)) ···· 4-204 図 4.4.2-17 プラント内 FP 分布(圧力容器破損前の電源復旧(TBU、BWR-5 Mark II)) ··· 4-205 図 4.4.2-18 プラント内 FP 分布(圧力容器破損後の電源復旧(TBU、BWR-5 Mark II)) ··· 4-205 図 4.4.2-19 プラント内 FP 分布(圧力容器破損前の電源復旧(S2B、BWR-5 Mark II)) ··· 4-206 図 4.4.2-20 プラント内 FP 分布(圧力容器破損後の電源復旧(S2B、BWR-5 Mark II)) ··· 4-206 図 4.4.2-21 プラント内 FP 分布(CRD 注水(TQUV、BWR-5 Mark II)) ·················· 4-207 li 図 4.4.2-22 プラント内 FP 分布(CUW 除熱あり(TQUV、BWR-5 Mark II)) ·············· 4-207 図 4.4.2-23 プラント内 FP 分布(CUW 除熱なし(TQUV、BWR-5 Mark II)) ·············· 4-208 図 4.4.2-24 プラント内 FP 分布(圧力容器破損前 DW クーラ(TQUV、BWR-5 Mark II)) ··· 4-208 図 4.4.2-25 プラント内 FP 分布(圧力容器破損後 DW クーラ(TQUV、BWR-5 Mark II)) ··· 4-209 図 4.4.2-26 プラント内 FP 分布(CRD 注水(TQUX、BWR-5 Mark II)) ·················· 4-209 図 4.4.2-27 プラント内 FP 分布(CUW 除熱あり(TQUX、BWR-5 Mark II)) ·············· 4-210 図 4.4.2-28 プラント内 FP 分布(CUW 除熱なし(TQUX、BWR-5 Mark II)) ·············· 4-210 図 4.4.2-29 プラント内 FP 分布(圧力容器破損前 DW クーラ(TQUX、BWR-5 Mark II)) ··· 4-211 図 4.4.2-30 プラント内 FP 分布(圧力容器破損後 DW クーラ(TQUX、BWR-5 Mark II)) ··· 4-211 図 4.4.2-31 プラント内 FP 分布(CRD 注水(AE、BWR-5 Mark II)) ···················· 4-212 図 4.4.2-32 プラント内 FP 分布(圧力容器破損前 DW クーラ(AE、BWR-5 Mark II)) ····· 4-212 図 4.4.2-33 プラント内 FP 分布(圧力容器破損後 DW クーラ(AE、BWR-5 Mark II)) ····· 4-213 図 4.4.2-34 事故シーケンスの事故進展タイミング(BWR-5 Mark II、AM あり) ·········· 4-214 図 4.4.2-35 事故シーケンスのソースターム(BWR-5 Mark II、AM あり) ················ 4-215 図 5.1-1 ABWR RCCV 型格納容器施設概要 ··········································· 5-6 図 5.1-2 ABWR 型原子炉圧力容器内部構造図 ········································ 5-7 図 5.1-3 ABWR RCCV 型原子炉施設の非常用炉心冷却系系統概略図 ····················· 5-8 図 5.1-4 ABWR RCCV 型原子炉施設のボリューム分割と流路 ··························· 5-9 図 5.1-5 ABWR の炉心部のセル分割 ················································ 5-10 図 5.2.1-1 原子炉冷却系水位(高圧・低圧注水失敗(TQUV、ABWR RCCV)) ·············· 5-36 図 5.2.1-2 炉心最高温度(高圧・低圧注水失敗(TQUV、ABWR RCCV)) ·················· 5-36 図 5.2.1-3 原子炉冷却系圧力(高圧・低圧注水失敗(TQUV、ABWR RCCV)) ·············· 5-37 図 5.2.1-4 格納容器系圧力(高圧・低圧注水失敗(TQUV、ABWR RCCV)) ················ 5-37 図 5.2.1-5 格納容器系温度(高圧・低圧注水失敗(TQUV、ABWR RCCV)) ················ 5-38 図 5.2.1-6 格納容器系水位(高圧・低圧注水失敗(TQUV、ABWR RCCV)) ················ 5-38 図 5.2.1-7 サプレッション・プールの水温 (高圧・低圧注水失敗(TQUV、ABWR RCCV)) ······························ 5-39 図 5.2.1-8 各放射性物質の環境放出量割合 (高圧・低圧注水失敗(TQUV、ABWR RCCV)) ····························· 5-39 図 5.2.2-1 原子炉冷却系水位 lii (小 LOCA 時の高圧・低圧注水失敗(S2QUV、ABWR RCCV)) ················· 5-40 図 5.2.2-2 格納容器系圧力 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、ABWR RCCV)) ················· 5-40 図 5.2.2-3 格納容器系温度 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、ABWR RCCV)) ················· 5-41 図 5.2.2-4 各放射性物質の環境放出量割合 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、ABWR RCCV)) ················· 5-41 図 5.2.3-1 原子炉冷却系水位(高圧注水・減圧失敗(TQUX、ABWR RCCV)) ·············· 5-42 図 5.2.3-2 格納容器系圧力(高圧注水・減圧失敗(TQUX、ABWR RCCV)) ················ 5-42 図 5.2.3-3 格納容器系温度(高圧注水・減圧失敗(TQUX、ABWR RCCV)) ················ 5-43 図 5.2.3-4 各放射性物質の環境放出量割合 (高圧注水・減圧失敗(TQUX、ABWR RCCV)) ····························· 5-43 図 5.2.4-1 原子炉冷却系水位(電源喪失(TB、ABWR RCCV)) ·························· 5-44 図 5.2.4-2 炉心最高温度(電源喪失(TB、ABWR RCCV)) ······························ 5-44 図 5.2.4-3 原子炉冷却系圧力(電源喪失(TB、ABWR RCCV)) ·························· 5-45 図 5.2.4-4 格納容器系圧力(電源喪失(TB、ABWR RCCV)) ···························· 5-45 図 5.2.4-5 格納容器系温度(電源喪失(TB、ABWR RCCV)) ···························· 5-46 図 5.2.4-6 格納容器系水位(電源喪失(TB、ABWR RCCV)) ···························· 5-46 図 5.2.4-7 サプレッション・プールの水温(電源喪失(TB、ABWR RCCV)) ·············· 5-47 図 5.2.4-8 各放射性物質の環境放出量割合(電源喪失(TB、ABWR RCCV)) ·············· 5-47 図 5.2.5-1 原子炉冷却系水位(小 LOCA 時の電源喪失(S2B、ABWR RCCV)) ·············· 5-48 図 5.2.5-2 格納容器系圧力(小 LOCA 時の電源喪失(S2B、ABWR RCCV)) ················ 5-48 図 5.2.5-3 格納容器系温度(小 LOCA 時の電源喪失(S2B、ABWR RCCV)) ················ 5-49 図 5.2.5-4 各放射性物質の環境放出量割合 (小 LOCA 時の電源喪失(S2B、ABWR RCCV)) ····························· 5-49 図 5.2.6-1 原子炉冷却系水位(電源喪失(TBU、ABWR RCCV)) ························· 5-50 図 5.2.6-2 格納容器系圧力(電源喪失(TBU、ABWR RCCV)) ··························· 5-50 図 5.2.6-3 格納容器系温度(電源喪失(TBU、ABWR RCCV)) ··························· 5-51 図 5.2.6-4 各放射性物質の環境放出量割合(電源喪失(TBU、ABWR RCCV)) ············· 5-51 図 5.2.7-1 原子炉冷却系水位(崩壊熱除去失敗(TW、ABWR RCCV)) ···················· 5-52 liii 図 5.2.7-2 炉心最高温度(崩壊熱除去失敗(TW、ABWR RCCV)) ························ 5-52 図 5.2.7-3 原子炉冷却系圧力(崩壊熱除去失敗(TW、ABWR RCCV)) ···················· 5-53 図 5.2.7-4 格納容器系圧力(崩壊熱除去失敗(TW、ABWR RCCV)) ······················ 5-53 図 5.2.7-5 格納容器系温度(崩壊熱除去失敗(TW、ABWR RCCV)) ······················ 5-54 図 5.2.7-6 格納容器系水位(崩壊熱除去失敗(TW、ABWR RCCV)) ······················ 5-54 図 5.2.7-7 サプレッション・プールの水温(崩壊熱除去失敗(TW、ABWR RCCV)) ········ 5-55 図 5.2.7-8 各放射性物質の環境放出量割合(崩壊熱除去失敗(TW、ABWR RCCV)) ········ 5-55 図 5.2.8-1 原子炉冷却系水位(小 LOCA 時の崩壊熱除去失敗(S2W、ABWR RCCV)) ········ 5-56 図 5.2.8-2 格納容器系圧力(小 LOCA 時の崩壊熱除去失敗(S2W、ABWR RCCV)) ·········· 5-56 図 5.2.8-3 格納容器系温度(小 LOCA 時の崩壊熱除去失敗(S2W、ABWR RCCV)) ·········· 5-57 図 5.2.8-4 各放射性物質の環境放出量割合 (小 LOCA 時の崩壊熱除去失敗(S2W、ABWR RCCV)) ······················· 5-57 図 5.2.9-1 原子炉冷却系水位(原子炉未臨界確保失敗(TC、ABWR RCCV)) ·············· 5-58 図 5.2.9-2 炉心最高温度(原子炉未臨界確保失敗(TC、ABWR RCCV)) ·················· 5-58 図 5.2.9-3 原子炉冷却系圧力(原子炉未臨界確保失敗(TC、ABWR RCCV)) ·············· 5-59 図 5.2.9-4 格納容器系圧力(原子炉未臨界確保失敗(TC、ABWR RCCV)) ················ 5-59 図 5.2.9-5 格納容器系温度(原子炉未臨界確保失敗(TC、ABWR RCCV)) ················ 5-60 図 5.2.9-6 格納容器系水位(原子炉未臨界確保失敗(TC、ABWR RCCV)) ················ 5-60 図 5.2.9-7 サプレッション・プールの水温 (原子炉未臨界確保失敗(TC、ABWR RCCV)) ······························ 5-61 図 5.2.9-8 各放射性物質の環境放出量割合 (原子炉未臨界確保失敗(TC、ABWR RCCV)) ····························· 5-61 図 5.2.10-1 原子炉冷却系水位 (小 LOCA 時の原子炉未臨界確保失敗(S2C、ABWR RCCV)) ················· 5-62 図 5.2.10-2 格納容器系圧力 (小 LOCA 時の原子炉未臨界確保失敗(S2C、ABWR RCCV)) ················· 5-62 図 5.2.10-3 格納容器系温度 (小 LOCA 時の原子炉未臨界確保失敗(S2C、ABWR RCCV)) ················· 5-63 図 5.2.10-4 各放射性物質の環境放出量割合 (小 LOCA 時の原子炉未臨界確保失敗(S2C、ABWR RCCV)) ················· 5-63 liv 図 5.2.11-1 原子炉冷却系水位(LOCA 時注水失敗(AE、ABWR RCCV)) ·················· 5-64 図 5.2.11-2 炉心最高温度(LOCA 時注水失敗(AE、ABWR RCCV)) ······················ 5-64 図 5.2.11-3 原子炉冷却系圧力(LOCA 時注水失敗(AE、ABWR RCCV)) ·················· 5-65 図 5.2.11-4 格納容器系圧力(LOCA 時注水失敗(AE、ABWR RCCV)) ···················· 5-65 図 5.2.11-5 格納容器系温度(LOCA 時注水失敗(AE、ABWR RCCV)) ···················· 5-66 図 5.2.11-6 格納容器系水位(LOCA 時注水失敗(AE、ABWR RCCV)) ···················· 5-66 図 5.2.11-7 サプレッション・プールの水温(LOCA 時注水失敗(AE、ABWR RCCV)) ······ 5-67 図 5.2.11-8 各放射性物質の環境放出量割合(LOCA 時注水失敗(AE、ABWR RCCV)) ······ 5-67 図 5.2.12-1 原子炉冷却系水位(インターフェイス LOCA(V、ABWR RCCV)) ············· 5-68 図 5.2.12-2 炉心最高温度(インターフェイス LOCA(V、ABWR RCCV)) ················· 5-68 図 5.2.12-3 原子炉冷却系圧力(インターフェイス LOCA(V、ABWR RCCV)) ············· 5-69 図 5.2.12-4 格納容器系圧力(インターフェイス LOCA(V、ABWR RCCV)) ··············· 5-69 図 5.2.12-5 格納容器系温度(インターフェイス LOCA(V、ABWR RCCV)) ··············· 5-70 図 5.2.12-6 格納容器系水位(インターフェイス LOCA(V、ABWR RCCV)) ··············· 5-70 図 5.2.12-7 サプレッション・プールの水温 (インターフェイス LOCA(V、ABWR RCCV)) ······························· 5-71 図 5.2.12-8 各放射性物質の環境放出量割合 (インターフェイス LOCA(V、ABWR RCCV)) ······························ 5-71 図 5.3.1.1-1 格納容器系圧力(圧力容器破損前のベント作動(TQUV、ABWR RCCV)) ······ 5-121 図 5.3.1.1-2 格納容器系温度(圧力容器破損前のベント作動(TQUV、ABWR RCCV)) ······ 5-121 図 5.3.1.1-3 格納容器系水位(圧力容器破損前のベント作動(TQUV、ABWR RCCV)) ······ 5-122 図 5.3.1.1-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TQUV、ABWR RCCV)) ····················· 5-122 図 5.3.1.2-1 格納容器系圧力(圧力容器破損後のベント作動(TQUV、ABWR RCCV)) ······ 5-123 図 5.3.1.2-2 格納容器系温度(圧力容器破損後のベント作動(TQUV、ABWR RCCV)) ······ 5-123 図 5.3.1.2-3 格納容器系水位(圧力容器破損後のベント作動(TQUV、ABWR RCCV)) ······ 5-124 図 5.3.1.2-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(TQUV、ABWR RCCV)) ····················· 5-124 図 5.3.1.3-1 格納容器系圧力(圧力容器破損前のベント作動(S2QUV、ABWR RCCV)) ····· 5-125 図 5.3.1.3-2 格納容器系温度(圧力容器破損前のベント作動(S2QUV、ABWR RCCV)) ····· 5-125 lv 図 5.3.1.3-3 格納容器系水位(圧力容器破損前のベント作動(S2QUV、ABWR RCCV)) ····· 5-126 図 5.3.1.3-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(S2QUV、ABWR RCCV)) ···················· 5-126 図 5.3.1.4-1 格納容器系圧力(圧力容器破損後のベント作動(S2QUV、ABWR RCCV)) ····· 5-127 図 5.3.1.4-2 格納容器系温度(圧力容器破損後のベント作動(S2QUV、ABWR RCCV)) ····· 5-127 図 5.3.1.4-3 格納容器系水位(圧力容器破損後のベント作動(S2QUV、ABWR RCCV)) ····· 5-128 図 5.3.1.4-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(S2QUV、ABWR RCCV)) ···················· 5-128 図 5.3.1.5-1 格納容器系圧力(圧力容器破損前のベント作動(TQUX、ABWR RCCV)) ······ 5-129 図 5.3.1.5-2 格納容器系温度(圧力容器破損前のベント作動(TQUX、ABWR RCCV)) ······ 5-129 図 5.3.1.5-3 格納容器系水位(圧力容器破損前のベント作動(TQUX、ABWR RCCV)) ······ 5-130 図 5.3.1.5-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TQUX、ABWR RCCV)) ····················· 5-130 図 4.3.1.6-1 格納容器系圧力(圧力容器破損後のベント作動(TQUX、ABWR RCCV)) ······ 5-131 図 4.3.1.6-2 格納容器系温度(圧力容器破損後のベント作動(TQUX、ABWR RCCV)) ······ 5-131 図 4.3.1.6-3 格納容器系水位(圧力容器破損後のベント作動(TQUX、ABWR RCCV)) ······ 5-132 図 4.3.1.6-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(TQUX、ABWR RCCV)) ····················· 5-132 図 5.3.1.7-1 格納容器系圧力(圧力容器破損前のベント作動(TW、ABWR RCCV)) ········ 5-133 図 5.3.1.7-2 格納容器系温度(圧力容器破損前のベント作動(TW、ABWR RCCV)) ········ 5-133 図 5.3.1.7-3 格納容器系水位(圧力容器破損前のベント作動(TW、ABWR RCCV)) ········ 5-134 図 5.3.1.7-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TW、ABWR RCCV)) ······················· 5-134 図 5.3.1.8-1 格納容器系圧力(圧力容器破損前のベント作動(S2W、ABWR RCCV)) ······· 5-135 図 5.3.1.8-2 格納容器系温度(圧力容器破損前のベント作動(S2W、ABWR RCCV)) ······· 5-135 図 5.3.1.8-3 格納容器系水位(圧力容器破損前のベント作動(S2W、ABWR RCCV)) ······· 5-136 図 5.3.1.8-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(S2W、ABWR RCCV)) ······················ 5-136 図 5.3.1.9-1 格納容器系圧力(圧力容器破損前のベント作動(TC、ABWR RCCV)) ········ 5-137 図 5.3.1.9-2 格納容器系温度(圧力容器破損前のベント作動(TC、ABWR RCCV)) ········ 5-137 lvi 図 5.3.1.9-3 格納容器系水位(圧力容器破損前のベント作動(TC、ABWR RCCV)) ········ 5-138 図 5.3.1.9-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(TC、ABWR RCCV)) ······················· 5-138 図 5.3.1.10-1 格納容器系圧力(圧力容器破損前のベント作動(S2C、ABWR RCCV)) ······ 5-139 図 5.3.1.10-2 格納容器系温度(圧力容器破損前のベント作動(S2C、ABWR RCCV)) ······ 5-139 図 5.3.1.10-3 格納容器系水位(圧力容器破損前のベント作動(S2C、ABWR RCCV)) ······ 5-140 図 5.3.1.10-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(S2C、ABWR RCCV)) ······················ 5-140 図 5.3.1.11-1 格納容器系圧力(圧力容器破損前のベント作動(AE、ABWR RCCV)) ······· 5-141 図 5.3.1.11-2 格納容器系温度(圧力容器破損前のベント作動(AE、ABWR RCCV)) ······· 5-141 図 5.3.1.11-3 格納容器系水位(圧力容器破損前のベント作動(AE、ABWR RCCV)) ······· 5-142 図 5.3.1.11-4 各放射性物質の環境放出量割合 (圧力容器破損前のベント作動(AE、ABWR RCCV)) ······················· 5-142 図 5.3.1.12-1 格納容器系圧力(圧力容器破損後のベント作動(AE、ABWR RCCV)) ······· 5-143 図 5.3.1.12-2 格納容器系温度(圧力容器破損後のベント作動(AE、ABWR RCCV)) ······· 5-143 図 5.3.1.12-3 格納容器系水位(圧力容器破損後のベント作動(AE、ABWR RCCV)) ······· 5-144 図 5.3.1.12-4 各放射性物質の環境放出量割合 (圧力容器破損後のベント作動(AE、ABWR RCCV)) ······················· 5-144 図 5.3.2.1-1 格納容器系圧力(圧力容器破損前の機器復旧(TQUV、ABWR RCCV)) ········ 5-145 図 5.3.2.1-2 格納容器系温度(圧力容器破損前の機器復旧(TQUV、ABWR RCCV)) ········ 5-145 図 5.3.2.1-3 格納容器系水位(圧力容器破損前の機器復旧(TQUV、ABWR RCCV)) ········ 5-146 図 5.3.2.1-4 各放射性物質の環境放出量割合 (圧力容器破損前の機器復旧(TQUV、ABWR RCCV)) ······················· 5-146 図 5.3.2.2-1 格納容器系圧力(圧力容器破損後の機器復旧(TQUV、ABWR RCCV)) ········ 5-147 図 5.3.2.2-2 格納容器系温度(圧力容器破損後の機器復旧(TQUV、ABWR RCCV)) ········ 5-147 図 5.3.2.2-3 格納容器系水位(圧力容器破損後の機器復旧(TQUV、ABWR RCCV)) ········ 5-148 図 5.3.2.2-4 各放射性物質の環境放出量割合 (圧力容器破損後の機器復旧(TQUV、ABWR RCCV)) ······················· 5-148 図 5.3.3.1-1 格納容器系圧力(圧力容器破損前の電源復旧(TB、ABWR RCCV)) ·········· 5-149 図 5.3.3.1-2 格納容器系温度(圧力容器破損前の電源復旧(TB、ABWR RCCV)) ·········· 5-149 lvii 図 5.3.3.1-3 格納容器系水位(圧力容器破損前の電源復旧(TB、ABWR RCCV)) ·········· 5-150 図 5.3.3.1-4 各放射性物質の環境放出量割合 (圧力容器破損前の電源復旧(TB、ABWR RCCV)) ························· 5-150 図 5.3.3.2-1 格納容器系圧力(圧力容器破損後の電源復旧(TB、ABWR RCCV)) ·········· 5-151 図 5.3.3.2-2 格納容器系温度(圧力容器破損後の電源復旧(TB、ABWR RCCV)) ·········· 5-151 図 5.3.3.2-3 格納容器系水位(圧力容器破損後の電源復旧(TB、ABWR RCCV)) ·········· 5-152 図 5.3.3.2-4 各放射性物質の環境放出量割合 (圧力容器破損後の電源復旧(TB、ABWR RCCV)) ························· 5-152 図 5.3.3.3-1 格納容器系圧力(圧力容器破損前の電源復旧(TBU、ABWR RCCV)) ········· 5-153 図 5.3.3.3-2 格納容器系温度(圧力容器破損前の電源復旧(TBU、ABWR RCCV)) ········· 5-153 図 5.3.3.3-3 格納容器系水位(圧力容器破損前の電源復旧(TBU、ABWR RCCV)) ········· 5-154 図 5.3.3.3-4 各放射性物質の環境放出量割合 (圧力容器破損前の電源復旧(TBU、ABWR RCCV)) ························ 5-154 図 5.3.3.4-1 格納容器系圧力(圧力容器破損後の電源復旧(TBU、ABWR RCCV)) ········· 5-155 図 5.3.3.4-2 格納容器系温度(圧力容器破損後の電源復旧(TBU、ABWR RCCV)) ········· 5-155 図 5.3.3.4-3 格納容器系水位(圧力容器破損後の電源復旧(TBU、ABWR RCCV)) ········· 5-156 図 5.3.3.4-4 各放射性物質の環境放出量割合 (圧力容器破損後の電源復旧(TBU、ABWR RCCV)) ························ 5-156 図 5.3.3.5-1 格納容器系圧力(圧力容器破損前の電源復旧(S2B、ABWR RCCV)) ········· 5-157 図 5.3.3.5-2 格納容器系温度(圧力容器破損前の電源復旧(S2B、ABWR RCCV)) ········· 5-157 図 5.3.3.5-3 格納容器系水位(圧力容器破損前の電源復旧(S2B、ABWR RCCV)) ········· 5-158 図 5.3.3.5-4 各放射性物質の環境放出量割合 (圧力容器破損前の電源復旧(S2B、ABWR RCCV)) ························ 5-158 図 5.3.3.6-1 格納容器系圧力(圧力容器破損後の電源復旧(S2B、ABWR RCCV)) ········· 5-159 図 5.3.3.6-2 格納容器系温度(圧力容器破損後の電源復旧(S2B、ABWR RCCV)) ········· 5-159 図 5.3.3.6-3 格納容器系水位(圧力容器破損後の電源復旧(S2B、ABWR RCCV)) ········· 5-160 図 5.3.3.6-4 各放射性物質の環境放出量割合 (圧力容器破損後の電源復旧(S2B、ABWR RCCV)) ························ 5-160 図 5.3.4.1-1 格納容器系圧力(CRD 注水(TQUV、ABWR RCCV)) ························ 5-161 図 5.3.4.1-2 格納容器系温度(CRD 注水(TQUV、ABWR RCCV)) ························ 5-161 lviii 図 5.3.4.1-3 格納容器系水位(CRD 注水(TQUV、ABWR RCCV)) ························ 5-162 図 5.3.4.1-4 各放射性物質の環境放出量割合(CRD 注水(TQUV、ABWR RCCV)) ·········· 5-162 図 5.3.4.2-1 格納容器系圧力(CUW 除熱あり/なし(TQUV、ABWR RCCV)) ··············· 5-163 図 5.3.4.2-2 格納容器系温度(CUW 除熱あり/なし(TQUV、ABWR RCCV)) ··············· 5-163 図 5.3.4.2-3 各放射性物質の環境放出量割合(CUW 除熱あり(TQUV、ABWR RCCV)) ······ 5-164 図 5.3.4.2-4 各放射性物質の環境放出量割合(CUW 除熱なし(TQUV、ABWR RCCV)) ······ 5-164 図 5.3.4.3-1 格納容器系圧力(圧力容器破損前 DW クーラあり/なし(TQUV、ABWR RCCV)) 5-165 図 5.3.4.3-2 格納容器系温度(圧力容器破損前 DW クーラあり/なし(TQUV、ABWR RCCV)) 5-165 図 5.3.4.3-3 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラあり(TQUV、ABWR RCCV)) ·················· 5-166 図 5.3.4.3-4 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラなし(TQUV、ABWR RCCV)) ·················· 5-166 図 5.3.4.4-1 格納容器系圧力(圧力容器破損後 DW クーラあり/なし(TQUV、ABWR RCCV)) 5-167 図 5.3.4.4-2 格納容器系温度(圧力容器破損後 DW クーラあり/なし(TQUV、ABWR RCCV)) 5-167 図 5.3.4.4-3 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラあり(TQUV、ABWR RCCV)) ·················· 5-168 図 5.3.4.4-4 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラなし(TQUV、ABWR RCCV)) ·················· 5-168 図 5.3.4.5-1 格納容器系圧力(CRD 注水(TQUX、ABWR RCCV)) ························ 5-169 図 5.3.4.5-2 格納容器系温度(CRD 注水(TQUX、ABWR RCCV)) ························ 5-169 図 5.3.4.5-3 格納容器系水位(CRD 注水(TQUX、ABWR RCCV)) ························ 5-170 図 5.3.4.5-4 各放射性物質の環境放出量割合(CRD 注水(TQUX、ABWR RCCV)) ·········· 5-170 図 5.3.4.6-1 格納容器系圧力(CUW 除熱あり/なし(TQUX、ABWR RCCV)) ··············· 5-171 図 5.3.4.6-2 格納容器系温度(CUW 除熱あり/なし(TQUX、ABWR RCCV)) ··············· 5-171 図 5.3.4.6-3 各放射性物質の環境放出量割合(CUW 除熱あり(TQUX、ABWR RCCV)) ······ 5-172 図 5.3.4.6-4 各放射性物質の環境放出量割合(CUW 除熱なし(TQUX、ABWR RCCV)) ······ 5-172 図 5.3.4.7-1 格納容器系圧力(圧力容器破損前 DW クーラあり/なし(TQUX、ABWR RCCV)) 5-173 図 5.3.4.7-2 格納容器系温度(圧力容器破損前 DW クーラあり/なし(TQUX、ABWR RCCV)) 5-173 図 5.3.4.7-3 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラあり(TQUX、ABWR RCCV)) ·················· 5-174 lix 図 5.3.4.7-4 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラなし(TQUX、ABWR RCCV)) ·················· 5-174 図 5.3.4.8-1 格納容器系圧力(圧力容器破損後 DW クーラあり/なし(TQUX、ABWR RCCV)) 5-175 図 5.3.4.8-2 格納容器系温度(圧力容器破損後 DW クーラあり/なし(TQUX、ABWR RCCV)) 5-175 図 5.3.4.8-3 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラあり(TQUX、ABWR RCCV)) ·················· 5-176 図 5.3.4.8-4 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラなし(TQUX、ABWR RCCV)) ·················· 5-176 図 5.3.4.9-1 格納容器系圧力(CRD 注水(AE、ABWR RCCV)) ·························· 5-177 図 5.3.4.9-2 格納容器系温度(CRD 注水(AE、ABWR RCCV)) ·························· 5-177 図 5.3.4.9-3 格納容器系水位(CRD 注水(AE、ABWR RCCV)) ·························· 5-178 図 5.3.4.9-4 各放射性物質の環境放出量割合(CRD 注水(AE、ABWR RCCV)) ············ 5-178 図 5.3.4.10-1 格納容器系圧力(圧力容器破損前 DW クーラあり/なし(AE、ABWR RCCV)) · 5-179 図 5.3.4.10-2 格納容器系温度(圧力容器破損前 DW クーラあり/なし(AE、ABWR RCCV)) · 5-179 図 5.3.4.10-3 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラあり(AE、ABWR RCCV)) ···················· 5-180 図 5.3.4.10-4 各放射性物質の環境放出量割合 (圧力容器破損前 DW クーラなし(AE、ABWR RCCV)) ···················· 5-180 図 5.3.4.11-1 格納容器系圧力(圧力容器破損後 DW クーラあり/なし(AE、ABWR RCCV)) · 5-181 図 5.3.4.11-2 格納容器系温度(圧力容器破損後 DW クーラあり/なし(AE、ABWR RCCV)) · 5-181 図 5.3.4.11-3 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラあり(AE、ABWR RCCV)) ······················ 5-182 図 5.3.4.11-4 各放射性物質の環境放出量割合 (圧力容器破損後 DW クーラなし(AE、ABWR RCCV)) ······················ 5-182 図 5.4.1-1 プラント内 FP 分布(高圧・低圧注水失敗(TQUV、ABWR RCCV)) ············· 5-190 図 5.4.1-2 プラント内 FP 分布 (小 LOCA 時の高圧・低圧注水失敗(S2QUV、ABWR RCCV)) ················· 5-190 図 5.4.1-3 プラント内 FP 分布(高圧注水・減圧失敗(TQUX、ABWR RCCV)) ············· 5-191 図 5.4.1-4 プラント内 FP 分布(電源喪失(TB、ABWR RCCV)) ························· 5-191 図 5.4.1-5 プラント内 FP 分布(小 LOCA 時の電源喪失(S2B、ABWR RCCV)) ············· 5-192 lx 図 5.4.1-6 プラント内 FP 分布(電源喪失(TBU、ABWR RCCV)) ························ 5-192 図 5.4.1-7 プラント内 FP 分布(崩壊熱除去失敗(TW、ABWR RCCV)) ··················· 5-193 図 5.4.1-8 プラント内 FP 分布(小 LOCA 時の崩壊熱除去失敗(S2W、ABWR RCCV)) ······· 5-193 図 5.4.1-9 プラント内 FP 分布(原子炉未臨界確保失敗(TC、ABWR RCCV)) ············· 5-194 図 5.4.1-10 プラント内 FP 分布 (小 LOCA 時の原子炉未臨界確保失敗(S2C、ABWR RCCV)) ················· 5-194 図 5.4.1-11 プラント内 FP 分布(LOCA 時注水失敗(AE、ABWR RCCV)) ················· 5-195 図 5.4.1-12 プラント内 FP 分布(インターフェイス LOCA(V、ABWR RCCV)) ············ 5-195 図 5.4.1-13 代表的な事故シーケンスの事故進展タイミング(ABWR RCCV、AM なし) ······ 5-196 図 5.4.1-14 代表的な事故シーケンスのソースターム(ABWR RCCV、AM なし) ············ 5-197 図 5.4.2-1 プラント内 FP 分布(圧力容器破損前のベント作動(TQUV、ABWR RCCV)) ····· 5-198 図 5.4.2-2 プラント内 FP 分布(圧力容器破損後のベント作動(TQUV、ABWR RCCV)) ····· 5-198 図 5.4.2-3 プラント内 FP 分布(圧力容器破損前のベント作動(TQUX、ABWR RCCV)) ····· 5-199 図 5.4.2-4 プラント内 FP 分布(圧力容器破損後のベント作動(TQUX、ABWR RCCV)) ····· 5-199 図 5.4.2-5 プラント内 FP 分布(圧力容器破損前のベント作動(TW、ABWR RCCV)) ······· 5-200 図 5.4.2-6 プラント内 FP 分布(圧力容器破損前のベント作動(TC、ABWR RCCV)) ······· 5-200 図 5.4.2-7 プラント内 FP 分布(圧力容器破損前のベント作動(S2C、ABWR RCCV)) ······ 5-201 図 5.4.2-8 プラント内 FP 分布(圧力容器破損前のベント作動(AE、ABWR RCCV)) ······· 5-201 図 5.4.2-9 プラント内 FP 分布(圧力容器破損後のベント作動(AE、ABWR RCCV)) ······· 5-202 図 5.4.2-10 プラント内 FP 分布 (圧力容器破損前のベント作動(S2QUV、ABWR RCCV)) ···················· 5-202 図 5.4.2-11 プラント内 FP 分布 (圧力容器破損後のベント作動(S2QUV、ABWR RCCV)) ···················· 5-203 図 5.4.2-12 プラント内 FP 分布(圧力容器破損前のベント作動(S2W、ABWR RCCV)) ····· 5-203 図 5.4.2-13 プラント内 FP 分布(圧力容器破損前の機器復旧(TQUV、ABWR RCCV)) ······ 5-204 図 5.4.2-14 プラント内 FP 分布(圧力容器破損後の機器復旧(TQUV、ABWR RCCV)) ······ 5-204 図 5.4.2-15 プラント内 FP 分布(圧力容器破損前の電源復旧(TB、ABWR RCCV)) ········ 5-205 図 5.4.2-16 プラント内 FP 分布(圧力容器破損後の電源復旧(TB、ABWR RCCV)) ········ 5-205 図 5.4.2-17 プラント内 FP 分布(圧力容器破損前の電源復旧(TBU、ABWR RCCV)) ······· 5-206 図 5.4.2-18 プラント内 FP 分布(圧力容器破損後の電源復旧(TBU、ABWR RCCV)) ······· 5-206 lxi 図 5.4.2-19 プラント内 FP 分布(圧力容器破損前の電源復旧(S2B、ABWR RCCV)) ······· 5-207 図 5.4.2-20 プラント内 FP 分布(圧力容器破損後の電源復旧(S2B、ABWR RCCV)) ······· 5-207 図 5.4.2-21 プラント内 FP 分布(CRD 注水(TQUV、ABWR RCCV)) ······················ 5-208 図 5.4.2-22 プラント内 FP 分布(CUW 除熱あり(TQUV、ABWR RCCV)) ·················· 5-208 図 5.4.2-23 プラント内 FP 分布(CUW 除熱なし(TQUV、ABWR RCCV)) ·················· 5-209 図 5.4.2-24 プラント内 FP 分布(圧力容器破損前 DW クーラ(TQUV、ABWR RCCV)) ······· 5-209 図 5.4.2-25 プラント内 FP 分布(圧力容器破損後 DW クーラ(TQUV、ABWR RCCV)) ······· 5-210 図 5.4.2-26 プラント内 FP 分布(CRD 注水(TQUX、ABWR RCCV)) ······················ 5-210 図 5.4.2-27 プラント内 FP 分布(CUW 除熱あり(TQUX、ABWR RCCV)) ·················· 5-211 図 5.4.2-28 プラント内 FP 分布(CUW 除熱なし(TQUX、ABWR RCCV)) ·················· 5-211 図 5.4.2-29 プラント内 FP 分布(圧力容器破損前 DW クーラ(TQUX、ABWR RCCV)) ······· 5-212 図 5.4.2-30 プラント内 FP 分布(圧力容器破損後 DW クーラ(TQUX、ABWR RCCV)) ······· 5-212 図 5.4.2-31 プラント内 FP 分布(CRD 注水(AE、ABWR RCCV)) ························ 5-213 図 5.4.2-32 プラント内 FP 分布(圧力容器破損前 DW クーラ(AE、ABWR RCCV)) ········· 5-213 図 5.4.2-33 プラント内 FP 分布(圧力容器破損後 DW クーラ(AE、ABWR RCCV)) ········· 5-214 図 5.4.2-34 代表的な事故シーケンスの事故進展タイミング(ABWR RCCV、AM あり) ······ 5-215 図 5.4.2-35 代表的な事故シーケンスのソースターム(ABWR RCCV、AM あり) ············ 5-216 lxii
© Copyright 2025 ExpyDoc