INDUSTRI A RESISTENZE ELETTRICHE RFH series ELECTRICAL RATINGS UL File Number: NMTR2.E335378 - NMTR8.E335378 DATASHEET ELECTRICAL RATINGS - Cat. No. RFH: Continuousduty Cat. No. Non continuous-duty Power Resistance Max. Voltage Tau Continuousduty Current Peak. non-cont Current Duty cycle P R Max. V τ I maxc I peak EDch [W] [Ohm] [V] [sec] [A] [A] RFH 75 45 from 1 to 300 600 300 RFH 100 60 from 1.5 to 360 600 300 EDch = Pmaxc/Ppeak = (Imaxc/Ipeak)2 RFH 165 80 from 2 to 720 600 300 = sqrt (P/R) = V/R RFH 220 100 from 2.2 to 870 600 400 If Ton > τ/10 If Ton < τ/10 Max Power = P Max Ppeak x EDch = P (Max Ppeak = V2/R) RFH 300 125 from 3 to 1100 600 500 RFH 400 150 from 3.7 to 1600 600 600 τ = thermal characteristic time of resistor; EDch = chopper duty cycle, Tonch/Ttotch. Continuous-duty Current is defined as the value of current in the resistor that produces the declared value of Power. Max. Current - Non continuous-duty is the maximum current for each resistor, calculated as the Voltage applied to the resistor (shall be not more than 600 V) divided per the value of the Resistance. I.R.E. INDUSTRIA RESISTENZE ELETTRICHE s.r.l - www.ireresistor.com - e-mail: [email protected] Via Valtellina, 2 - 20027 Rescaldina (MI) - Tel. (+39) 0331.577.833 - Fax (+39) 0331.577.832 - P. IVA IT11267750153 1
© Copyright 2024 ExpyDoc