International measurement campaign at Kanne, Belgium, October

departement
Mobiliteit en
Openbare Werken
International measurement campaign at
Kanne, Belgium, October 17th 2013
COMPARING ADP FLOW MEASUREMENTS BY
Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and
Direction générale opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
00_146
WL Adviezen
Vlaamse overheid
International measurement campaign at
Kanne, Belgium, October 17th 2013
Comparing ADP flow measurements by Flanders Hydraulics
(HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Cornet, E.; Vereecken, H.; Deschamps, M.; Verwaest, T.; Mostaert, F.
November 2014
WL2014A00_146_1
F-WL-PP10-1 Versie 04
GELDIG VANAF: 12/11/2012
This publication must be cited as follows:
Cornet, E.; Vereecken, H.; Deschamps, M.; Verwaest, T.; Mostaert, F. (2014). International measurement
campaign at Kanne, Belgium, October 17th 2013: Comparing ADP flow measurements by Flanders Hydraulics
(HIC), Rijkswaterstaat (RWS) and Direction générale opérationnelle de la Mobilité et des Voies hydrauliques
(SETHY). Version 4.0. WL Adviezen, 00_146. Flanders Hydraulics Research: Antwerp, Belgium.
Waterbouwkundig Laboratorium
Flanders Hydraulics Research
Berchemlei 115
B-2140 Antwerp
Tel. +32 (0)3 224 60 35
Fax +32 (0)3 224 60 36
E-mail: [email protected]
www.watlab.be
Nothing from this publication may be duplicated and/or published by means of print, photocopy, microfilm or
otherwise, without the written consent of the publisher.
F-WL-PP10-1 Versie 04
GELDIG VANAF: 12/11/2012
Document identification
Title:
International measurement campaign at Kanne, Belgium, October 17th 2013: Comparing
ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and
Direction générale opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Customer:
WL
Keywords (3-5):
ADCP, debieten, AGILA
Text (p.):
16
Confidentiality:
☐ Yes
Ref.:
WL2014A00_146_1
Appendices (p.):
19
☐ Customer
Exceptions:
☐ Internal
☐ Flemish government
Released as from:
☒ No
☐ Available online
Approval
Author
Reviser
Project Leader
HIC (Support Centre)
Manager
Head of Division
Cornet, E.
Claeys, S.
Vereecken, H.
Deschamps, M.
Mostaert, F.
Coordinator Study &
Advice
Verwaest, T.
Revisions
Nr.
Date
Definition
Author(s)
1.0
15/01/2014
Concept version
Cornet, E.
2.0
30/04/2014
Substantive revision
Vereecken, H.
3.0
18/11/2014
Revision customer
Deschamps, M.
4.0
27/11/2014
Final version
Vereecken, H.
Abstract
On October 17th 2013, an international measurement campaign on the Albert Canal at Kanne-Vroenhoven (B)
took place with hydrometrists from the Flemish HIC, Dutch RWS and Walloon SETHY. The aim was to compare
by means of simultaneous measurements the results produced by the calibration ADP-instruments of all three
institutes and to favor best-practices and knowledge exchange.
After a former measurement campaign (river Meuse/Maastricht 20/11/2012), focus was now on measuring
discharges at low velocities. Each group deployed a trimaran mounted RDI- instrument, while RWS additionnally
brought into action the “Observant”, a small manned and ADP-equipped measuring vessel.
This report compares all measured discharge data to the simultaneous 10 sec. discharge data produced by the
Kanne acoustic flowmeter (ADM).
F-WL-PP10-1 Versie 04
GELDIG VANAF: 12/11/2012
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Contents
1.
Introduction ............................................................................................................................................... 1
2.
Methodology ............................................................................................................................................. 2
3.
2.1.
Situation of measurements ............................................................................................................... 2
2.2.
Measurement methodology ............................................................................................................... 3
2.3.
Measurement results ......................................................................................................................... 4
Conclusion ................................................................................................................................................ 5
Annex : MEMO Comparison on measured profiles .......................................................................................A0
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
I
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
List of table s
Table 1 - chronological measurement results .................................................................................................. 6
Table 2 - selected calibrations ......................................................................................................................... 7
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
II
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
List of figures
Figure 1 - Location of the ADP-measurements on the Albert Canal at Kanne-Vroenhoven ........................... 2
Figure 2 - ADP-measurement area.................................................................................................................. 3
Figure 3 - AGILA corrected profiles by HIC ..................................................................................................... 8
Figure 4 - AGILA corrected profiles by SETHY ............................................................................................... 8
Figure 5 - AGILA corrected profiles by RWS (RiverRay) ................................................................................. 9
Figure 6 - AGILA corrected profiles by RWS (Observant) ............................................................................... 9
Figure 7 - HIC track with Q = 47 m³/s, cell-size = 20cm (RioGrande) ........................................................... 10
Figure 8 - SETHY track with Q = 28 m³/s, cell-size = 10cm (RioGrande) ..................................................... 11
Figure 9 - RWS-RiverRay track with Q = 49 m³/s, cell-size = automatic (RiverRay) ..................................... 12
Figure 10 - RWS (Observant) track with Q = 54 m³/s, cell-size = 25cm (RioGrande) ................................... 13
Figure 11 - AGILA corrected profiles by all parties ........................................................................................ 14
Figure 12 - AGILA corrected measured mean velocities-discharge by all parties ......................................... 14
Figure 13 - calibrated discharge vs. simultaneously ADM-discharge ............................................................ 15
Figure 14 - calibrated discharge vs. simultaneously ADM-discharge for all transects without navigation
influenced transects ....................................................................................................................................... 15
Figure 15 - correction of ADM-flow (Qcont) with rating Q = 0.85343 * Qcont ^ 1.0839 ................................ 16
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
III
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
1. Introduction
On October 17th 2013, an international measurement campaign on the Albert Canal at Kanne-Vroenhoven
(B) took place with hydrometrists from the Flemish HIC, Dutch RWS and Walloon SETHY (now called
DGO2). The aim was to compare by means of simultaneous measurements the results produced by the
calibration ADP-instruments of all three institutes and to favor best-practices and knowledge exchange.
After a former measurement campaign (river Meuse/Maastricht 20/11/2012), focus was now on measuring
discharges at low velocities on a canal.
This report compares all measured discharge data to the simultaneous 10 sec. discharge data produced by
the Kanne acoustic flowmeter (ADM).
Each group operated a trimaran mounted RDI ADP-instrument, while RWS additionnally brought into action
the “Observant”, a small manned and ADP-equipped measuring vessel (600kHz).
Unlike HIC and SETHY who used a RDI-RioGrande-Workhorse (1200kHz), RWS used a new RDI RiverRay
instrument.
According to technical specifications, the RiverRay is reported to have improved features including :
•
•
•
•
Profiling range from 0,4 to 40m
Streamvelocity accuracy of 2mm/s
Automatic cell size with 10cm min.
Better surface layer measurements
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
1
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
2. Methodology
2.1. Situation of measurements
Fig. 1 shows the Kanne area with the ADP-measurements site.
Fig. 2 zooms in on the measurements area.
Figure 1 - Location of the ADP-measurements on the Albert Canal at Kanne-Vroenhoven
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
2
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Figure 2 - ADP-measurement area
2.2. Measurement methodology
The ADP-trimarans of all three parties were fixed at an outboard engine driven zodiac and slowly sailed at
constant speed from one shore to the other with measured data instantaneously being monitored on laptop.
The zodiac captain shouted the end of transect at reaching the other riverbank.
Simultaneously, 33 tracks were sailed by the Observant, the first track being a loop cruise to detect possible
moving bed occurrence, with Qtotal tending to zero. Remaining Observant-tracks were sailed along a
straight line perpendicular on the canal bank.
Clocks were exactly set equal in local time on all instruments. The instruments were operated without GPS,
since with thus proved absence of moving bottom, the riverbed scanning by the ADP-bottom track function
did not have to result in systematic discharge underestimation. This means that boat velocities relative to
the bottom could be detected and the measured water velocities can be corrected in that way.
To each transect a corresponding value of the ADM continuous flowmeter Qcont was linked. Since all
measuring devices were set to second’s precision, a Qcont value could per valid transect be computed
using the ADM 10 sec output and linked (automatically, according to example below).
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
3
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
2.3. Measurement results
Table 1 show all transects chronologically performed by all parties.
As shown in fig. 3-7 DES-graphs, all transects appeared, based on measured wet profiles, to be normally
sailed. The Observant-measured profiles (some 50-100m downstream) don’t seem to differ significantly
from the trimaran ones, with profile widths fluctuating around 100m.
All these profiles were obtained by recalculating WinRiver ASCII-output in AGILA with reference of crosssection set to 65° (fig. 2). This approach turned out to be the best, in contradiction to the cross-section
reference being usually set by AGILA perpendicular to the resulting mean velocity vector. This vector is
likely to be most unstable at low values and far from parrallel with the canal banks, resulting in distorted
profiles with unrealistic width values.
As a result a satisfactory relation (R = 0.97) between measured and continuous discharge values could be
obtained for the selected measurements (fig. 13). This allows, as shown in fig. 14, for a correction of the
continuous discharge data :
Q = 0.85343 * Qcont ^ 1.0839
Validity date for this equation is is set on 01/01/2013.
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
4
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
3. Conclusion
The prerequisite to all calibration measurement, namely an accurate measured wet profile over all tracks
per instrument, was met. The trimaran-profiles, regardless of chosen distances to the shores, are also very
much resembling to each other and so are the Observant upstream measured profiles.
Comparing simultaneously operating calibration instruments with each other did not reveal one or other
instrument to measure with significant systematic errors.
10 out of the 50 performed transects (fig. 9) had to be considered invalid and were discarded (fig. 10).
A reason fort his was :
-
the above mentioned bad AGILA-profile resulting at low mean velocity
-
disturbance of the transect measurement by passing vessels
or a combination of both.
This left Sethy (DGO2) with only one valid track at substantial discharge (30 m³/s).
As a result of this campaign a correction of the continuous discharge data was proposed. The proposed
correction is emphasized in a separate memo (in Dutch), attached to this report. Possible causes and
solutions are described.
We would like to thank all participants for this measurement campaign.
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
5
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Table 1 - chronological measurement results
(Qcal = calibration measured discharge – Qcont = ADM discharge)
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
6
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Table 2 - selected calibrations
(AGILA output with automatic (mean width = 92,48m) and with 65° (mean width = 99,89m)
imposed cross-section reference)
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
7
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Figure 3 - AGILA corrected profiles by HIC
Figure 4 - AGILA corrected profiles by SETHY
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
8
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Figure 5 - AGILA corrected profiles by RWS (RiverRay)
Figure 6 - AGILA corrected profiles by RWS (Observant)
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
9
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
0
0.1
0.2
0.3
5.5
5
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
10
Messstelle
Gewässer
Fluß-km
Datum der Messung
Uhrzeit
-0.1
Tiefe unter Wsp [m]
Vm(proj.) [m/s]
:
:
:
:
:
20
Kanne ADM
Albertkanaal
0.000
17/10/2013
09:02:56
30
W
Q
A
b
Vm
Vob
=
=
=
=
=
=
40
70
h,m
h,max
r,hy
P
C*Wurzel(I)
Vob,max
50
60
Abstand vom Nullpunkt [m]
-999 cm
46.46 m³/s
503.81 m²
103.32 m
0.09 m/s
0.15 m/s
=
=
=
=
=
=
80
4.88 m
5.58 m
4.60 m
1133.75 m^2½
0.04 m^½/s
0.38 m/s
100
Federal Institute of Hydrology, Germany
90
>
0.15
<= 0.15
<= 0.14
<= 0.13
<= 0.12
<= 0.11
<= 0.10
<= 0.09
<= 0.08
<= 0.07
<= 0.06
<= 0.05
<= 0.04
<= 0.03
<= 0.02
<= 0.01
<= 0.00
V [m/s]
Ausw ertung einer ADCP-Messung m it AGILA 7 Datei: W:\HIC\Datavalidatie\Q_ijk\ijkm etingen_terrein\BINNENKOMENDE ijkingen\Metingen Kanne RWS-HIC-SETHY 2013\HIC Riogrand
Vm (proj.) m it Darstellung der projizierten Fließgeschw indigkeiten im Querschnitt
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Figure 7 - HIC track with Q = 47 m³/s, cell-size = 20cm (RioGrande)
ervant)
10
Vm(proj.) [m/s]
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
Tiefe unter Wsp [m]
20
30
40
60
50
Abstand vom Nullpunkt [m]
70
h,m
h,max
r,hy
P
C*Wurzel(I)
Vob,max
=
=
=
=
=
=
80
4.73 m
5.76 m
4.30 m
1093.02 m^2½
0.03 m^½/s
0.59 m/s
90
100
<= 0.70
<= 0.60
<= 0.50
<= 0.40
<= 0.30
<= 0.20
<= 0.10
<= 0.00
V [m/s]
WL2014A00_146_1
5.5
5
4.5
4
3.5
3
2.5
2
Federal Institute of Hydrology, Germany
>
1.70
<= 1.70
<= 1.60
<= 1.50
<= 1.40
<= 1.30
<= 1.20
<= 1.10
<= 1.00
10
-999 cm
27.80 m³/s
490.17 m²
103.67 m
0.06 m/s
0.12 m/s
1.5
=
=
=
=
=
=
<= 0.90
W
Q
A
b
Vm
Vob
1
0
Kanne ADM
Albertkanaal
0.000
17/10/2013
09:13:50
<= 0.80
:
:
:
:
:
0.5
0
0.1
0.2
Messstelle
Gewässer
Fluß-km
Datum der Messung
Uhrzeit
Ausw ertung einer ADCP-Messung m it AGILA 7 Datei: W:\HIC\Datavalidatie\Q_ijk\ijkm etingen_terrein\BINNENKOMENDE ijkingen\Metingen Kanne RWS-HIC-SETHY 2013\Sethy Riog
Vm (proj.) m it Darstellung der projizierten Fließgeschw indigkeiten im Querschnitt
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Figure 8 - SETHY track with Q = 28 m³/s, cell-size = 10cm (RioGrande)
11
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
0
0.1
0.2
0.3
0.4
20
30
=
=
=
=
=
=
40
h,m
h,max
r,hy
P
C*Wurzel(I)
Vob,max
50
60
Abstand vom Nullpunkt [m]
-999 cm
48.79 m³/s
497.00 m²
100.90 m
0.10 m/s
0.18 m/s
70
=
=
=
=
=
=
80
4.93 m
5.71 m
4.11 m
1123.89 m^2½
0.04 m^½/s
0.74 m/s
90
100
<= 0.70
<= 0.60
<= 0.50
<= 0.40
<= 0.30
<= 0.20
<= 0.10
<= 0.00
V [m/s]
5.5
5
4.5
4
3.5
3
2.5
2
1.5
Figure 9 - RWS-RiverRay track with Q = 49 m³/s, cell-size = automatic (RiverRay)
12
Federal Institute of Hydrology, Germany
>
1.70
<= 1.70
<= 1.60
<= 1.50
<= 1.40
<= 1.30
<= 1.20
<= 1.10
<= 1.00
<= 0.90
W
Q
A
b
Vm
Vob
1
10
Kanne ADM
Albertkanaal
0.000
17/10/2013
11:01:33
<= 0.80
:
:
:
:
:
0.5
-0.2
0
Messstelle
Gewässer
Fluß-km
Datum der Messung
Uhrzeit
-0.1
Tiefe unter Wsp [m]
Vm(proj.) [m/s]
Ausw ertung einer ADCP-Messung m it AGILA 7 Datei: W:\HIC\Datavalidatie\Q_ijk\ijkm etingen_terrein\BINNENKOMENDE ijkingen\Metingen Kanne RWS-HIC-SETHY 2013\Rijksw ater
Vm (proj.) m it Darstellung der projizierten Fließgeschw indigkeiten im Querschnitt
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Vm(proj.) [m/s]
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
Tiefe unter Wsp [m]
20
30
40
50
Abstand vom Nullpunkt [m]
60
h,m
h,max
r,hy
P
C*Wurzel(I)
Vob,max
70
=
=
=
=
=
=
80
5.01 m
5.77 m
4.64 m
1128.74 m^2½
0.05 m^½/s
0.40 m/s
90
100
<= 0.70
<= 0.60
<= 0.50
<= 0.40
<= 0.30
<= 0.20
<= 0.10
<= 0.00
V [m/s]
WL2014A00_146_1
5.5
5
4.5
4
3.5
3
2.5
2
Figure 10 - RWS (Observant) track with Q = 54 m³/s, cell-size = 25cm (RioGrande)
13
Federal Institute of Hydrology, Germany
>
1.70
<= 1.70
<= 1.60
<= 1.50
<= 1.40
<= 1.30
<= 1.20
<= 1.10
<= 1.00
10
-999 cm
53.63 m³/s
497.80 m²
99.38 m
0.11 m/s
0.13 m/s
1.5
=
=
=
=
=
=
<= 0.90
W
Q
A
b
Vm
Vob
1
0
Kanne ADM
Albertkanaal
0.000
17/10/2013
09:03:31
<= 0.80
:
:
:
:
:
0.5
0
0.1
0.2
0.3
Messstelle
Gewässer
Fluß-km
Datum der Messung
Uhrzeit
Ausw ertung einer ADCP-Messung m it AGILA 7 Datei: W:\HIC\Datavalidatie\Q_ijk\ijkm etingen_terrein\BINNENKOMENDE ijkingen\Metingen Kanne RWS-HIC-SETHY 2013\Rijksw atersta
Vm (proj.) m it Darstellung der projizierten Fließgeschw indigkeiten im Querschnitt
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Figure 11 - AGILA corrected profiles by all parties
Figure 12 - AGILA corrected measured mean velocities-discharge by all parties
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
14
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Figure 13 - calibrated discharge vs. simultaneously ADM-discharge
Figure 14 - calibrated discharge vs. simultaneously ADM-discharge
for all transects without navigation influenced transects
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
15
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Figure 15 - correction of ADM-flow (Qcont) with rating Q = 0.85343 * Qcont ^ 1.0839
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
16
International measurement campaign at Kanne, Belgium, October 17th 2013:
Comparing ADP flow measurements by Flanders Hydraulics (HIC), Rijkswaterstaat (RWS) and Direction générale
opérationnelle de la Mobilité et des Voies hydrauliques (SETHY)
Annex : MEMO Comparison on measured profiles
Final version
F-WL-PP10-1 Version 04
RELEASED AS FROM: 12/11/2012
WL2014A00_146_1
A0
MEMO
Titel
Vergelijking opgemeten profielen ter hoogte van de akoustische debietmeter
op het Albertkanaal te Kanne
Datum
21/10/2014
Auteur(s)
Hans Vereecken
Ref.:
WL2014M00_146_1
Inleiding
In 2013 werd in het kader van internationale afstemming met de ons omringende regio’s een
gezamenlijke debietmeting uitgevoerd ter hoogte van de continue debietmeetpost op het Albertkanaal
te Kanne. Figuur 1 toont de ligging van de debietmeter. Het meettoestel is van het type akoustische
looptijdmeter en bestaat uit 2 schuin in het water liggende meetkruisen. Het technisch onderhoud van
het toestel wordt uitbesteed aan de firma Elster-Instromet. In 2010 werd door het WL-HIC opdracht
gegeven aan Elster-Instromet om het profiel opnieuw in te meten en te programmeren in de software
van het toestel, de zogenaamde FLOW-2000.
Lambert72 X: 240088
Lambert72 Y: 169124
Figuur 1 – ligging debietmeter te Kanne – foto toont afstand op rechteroever (rode lijn)
tussen 2 beamposities (85m)
Vergelijking opgemeten profielen ter hoogte van de akoustische debietmeter op het Albertkanaal te Kanne
Figuur 2 – gemiddeld profiel te Kanne afgeleid uit 11 profielmetingen,
opgemeten met multibeam door geoXYZ in 2010.
Het profiel dat in 2010 door GeoXYZ, als onderaannemer van Elster-Instromet, werd opgeleverd wordt
getoond in figuur 2. Dit profiel is een gemiddeld profiel afgeleid uit 11 dwarsprofielmetingen die in de
zone van de ADM-opstelling werd opgemeten met behulp van een Seabat 8125 multibeam, met een
meefrequentie van 455 kHz.
In het najaar van 2010 werden de programmatie van de real-time berekende debieten in de
FLOW-2000 dan ook aangepast met deze nieuwe opmetingen, om zo goed mogelijke rechtstreeks
gemeten debieten te kunnen aanleveren.
WL2014M00_146_1
2
Vergelijking opgemeten profielen ter hoogte van de akoustische debietmeter op het Albertkanaal te Kanne
Resultaten gezamenlijke metingen 2013
Op 17/10/2013 werden door het WL-HIC (Waterbouwkundig Laboratorium-Hydrologisch Informatie
Centrum) samen met Rijkswaterstaat Directie Limburg en met de Waalse collega’s van Sethy
gezamenlijk debietmetingen verricht ter hoogte van de ADM dit in het kader van afstemming van
debieten aan de lands- en regiogrenzen. Een overzicht van de meetinstrumenten en de belangrijkste
resultaten werd gegeven in een advies (WL2014100_146_1).
De belangrijkste conclusie van deze dag was dat alle ingezette meetapparatuur (type ADCP) zeer
vergelijkbare resultaten opleverden. Ten opzichte van de continue looptijdmeter (Qcont) echter bleken
de ADCP debieten (QADCP) nagenoeg steeds hogere debieten op te leveren, wat resulteerde in het
volgende verband:
QADCP = 0.85343 * Qcont ^ 1.0839
Dit betekent dat de debieten voortaan zouden moeten worden omgerekend met een factor om te
komen tot de werkelijke debieten. Tabel 1 toont enkele rekenvoorbeelden. Dit betekent vanaf debieten
van 20 m³/s een onderschatting met 10%, bij de zeer extreme, zij het kortstondige, debieten van
bijvoorbeeld 125 m³/s die optreden betekent dit een onderschatting van meer dan 25%.
Tabel 1 – rekenvoorbeelden van de omrekening van de continue ADM-debieten naar reëele debieten,
afgeleid uit de gezamenlijk uitgevoerde ADCP metingen van 17/10/2013.
De bevindingen van deze metingen werden begin 2014 teruggekoppeld met Instromet, de
onderhoudsfirma van de ADM-looptijdmeter te Kanne, aangezien dergelijk grote verschillen in het
verleden nog niet werden vastgesteld.
Hun detailanalyse van de metingen deed hen besluiten dat de door de ADCP gemeten
stroomsnelheden en deze van de ADM zeer goed overeenstemmen (Figuur 3). De grote verschillen in
de metingen worden vooral veroorzaakt door een groot verschil tussen de door de ADCP’s opgemeten
dwarsprofielen en het in de ADM FLOW-2000 geprogrammeerde dwarsprofiel (opgemeten in 2010
door geoXYZ). Figuur 4 toont de m² oppervlakte opgemeten door de ADCP’s en deze die tegelijk
worden aangegeven in de FLOW-2000. Hieruit blijkt wel degelijk dat de ADCP’s meer oppervlakte
meten dan in de FLOW-2000 is geprogrammeerd. Volgens de memo 1000094571 van de heer
Lambrechts (Elster-Instromet) in bijlage, kan het profiel te Kanne niet dieper zijn dan 5,25m, dit terwijl
de ADCP dieptes meet tot gemiddeld 5,70m.
WL2014M00_146_1
3
Vergelijking opgemeten profielen ter hoogte van de akoustische debietmeter op het Albertkanaal te Kanne
Figuur 3 – vergelijking opgemeten gemiddelde stroomsnelheden ADCP’s (blauw) en ADM (rood)
tijdens de meting van 17/10/2014.
Figuur 4 – m² dwarsprofiel te Kanne afgeleid uit de ADCP metingen (blauw) en
uit de FLOW-2000 installatie (rood) tijdens de meting van 17/10/2014.
WL2014M00_146_1
4
Vergelijking opgemeten profielen ter hoogte van de akoustische debietmeter op het Albertkanaal te Kanne
De verschillen tussen deze profielen zouden verschillende oorzaken kunnen hebben:
•
•
•
het profiel is veranderd door de jaren heen, in dit geval uitgeschuurd
de manier waarop profielen gemeten worden met ADCP en multibeam is verschillend, wat kan
resulteren in andere resultaten
er is een fout gebeurd bij de ADCP-metingen of de profielmeting in 2010
Hieronder worden kort de verschillende mogelijkheden verder onderzocht.
Stelling 1 - het profiel is door de jaren heen uitgeschuurd
Gezien de lage stroomsnelheden die optreden in het Albertkanaal (maximale gemiddelde
stroomsnelheden ongeveer 0,25 m/s) lijkt het onmogelijk dat het profiel is geërodeerd. Terugkoppeling
met de beheerder, in case nv de Scheepvaart, leert ons dat er ook geen profielaanpassingen zijn
gebeurd in de periode 2010-2014.
CONCLUSIE: stelling 1 klopt niet
Stelling 2 - de manier waarop profielen gemeten worden met ADCP en multibeam zijn
verschillend, wat kan resulteren in andere resultaten
ADCP’s meten in het algemeen met een hogere frequentie dan multibeam toestellen. Hieronder vindt u
in tabel 2 een overzicht van de verschillende gebruikte ADCP’s en hun meetfrequentie versus het in
2010 gebruikte multibeam-toestel. In theorie leiden in het algemeen hogere geluidsfrequenties tot
minder diepe metingen, wat hier betekent dat de meting van geoXYZ zeker niet minder diep zou
mogen zijn dan de ADCP metingen.
Tabel 2 – overzicht gebruikte meetinstrumenten tijdens de metingen van 17/10/2013 versus het type
gebruikt bij de profielopmeting in 2010.
CONCLUSIE: zonder verdere detailanalyse durven we stellen dat stelling 2 eveneens niet klopt
Stelling 3 - er is een fout gebeurd bij de ADCP-metingen of de profielmeting in 2010
Detailanalyse van de verschillende profielen die sinds de oprichting van de ADM-installatie te Kanne
(1998) werden opgemeten met multibeam en opgemeten tijdens de doorheen de jaren uitgevoerde
ADCP ijkingsmetingen ter plaatse leert ons dat alle uitgevoerde ADCP metingen nagenoeg eenzelfde
profiel vertonen. Enkel het met multibeam opgemeten profiel van 2010 ligt duidelijk hoger in figuur 5.
Om alle discussie te vermijden werd aan de meetdienst van Rijkswaterstaat Limburg gevraagd om in
de zone van de ADM-installatie met hun meetboot een multibeam opname uit te voeren in de zomer
WL2014M00_146_1
5
Vergelijking opgemeten profielen ter hoogte van de akoustische debietmeter op het Albertkanaal te Kanne
van 2014. Dit betreft een EM3002 Dualhed multibeam met een meetfrequentie van 300kHz. Te allen
tijde moet te meting die RWS Limburg uitvoert op een geijkte drempel beter zijn dan +- 5 cm. Dit werd
voor aanvang van de profielmeting in Kanne eveneens gecontroleerd en goed bevonden.
Alle opmeten profielen zijn weergegeven op onderstaande figuur 5.
Figuur 5 – profiel te Kanne afgeleid uit profielmetingen van 2010-2014.
Hieruit leiden we af dat de ADCP profielmetingen, zelfs deze van 2010, sterke gelijkenissen tonen met
de in 2014 door RWS Limburg uitgevoerde profielmeting met multibeam. Dit doet ons besluiten dat er
bij de opmeting van het profiel in 2010 door geoXYZ een fout is gebeurd.
CONCLUSIE: stelling 3 klopt hoogstwaarschijnlijk, namelijk bij de profielopmeting in 2010 met
multibeam is een fout gebeurd en het profiel dat in 2010 is opgemeten met multibeam moet tot
ongeveer 0,5 m dieper zijn. Daarnaast concluderen we dat de ADCP profielen van 2013 zeer sterk
gelijken op de multibeam meting van 2014, wat eveneens stelling 2 ontkracht.
WL2014M00_146_1
6
Vergelijking opgemeten profielen ter hoogte van de akoustische debietmeter op het Albertkanaal te Kanne
Besluit
Door een foutieve opmeting van het dwarsprofiel ter hoogte van de ADM te Kanne in 2010, en de
daaruit afgeleide herprogrammatie van de debietmeter in het najaar van 2010, moet voor de
debietreeks te Kanne een historische correctie worden doorgevoerd volgens de formule:
Qreëel = 0.85343 * Qcont ^ 1.0839,
met Qcont = de debieten gemeten door de ADM
en Qreëel = de reëele gevalideerde debieten
Aan de firma Elster-Instromet, verantwoordelijk voor het onderhoud en de programmatie van deze
toestellen, zal ook gevraagd worden om de laatste goed uitgevoerde multibeammeting, zijnde deze
van de zomer 2014 opgemeten door RWS Limburg, te gebruiken om vanaf 1/1/2015 de debietmeter te
Kanne te herprogrammeren zodat de ADM terug de best mogelijke debieten zal opleveren.
WL2014M00_146_1
7
Vergelijking opgemeten profielen ter hoogte van de akoustische debietmeter op het Albertkanaal te Kanne
Bijlage – memo 1000094571 van de heer Lambrechts van
Elster-Instromet
WL2014M00_146_1
8
MEMO
Datum :
5 mei ’14
Opdracht nummer :
1000094571
Aan :
Waterbouwkundig Laboratorium, dhr. H. Vereecken
Van :
W. Lambrechts
Onderwerp :
metingen
Vergelijk metingen ADM Kanne–Noord met ADCP
Na aanleiding van uw vraag waarom de ADM Kanne–Noord steeds een lagere
afvoer berekend dan de diverse ACDP systemen waarmee op 17 oktober 2013
vergelijkende metingen zijn gedaan.
Door u zijn beschikbaar gesteld :
• De berichten welke door de FLOW-2000 in de periode van de
vergelijkmetingen zijn uitgegeven.
• De lijst met de resultaten van de vergelijkmetingen van 17 oktober 2013
en eerder.
Wij hebben al deze gegevens in een spreadsheet samengevat, zie bijlage.
Wij hebben ons beperkt tot de vergelijkmetingen van 17 oktober 2013.
Het eerste wat opvalt aan de tabel met de verzamelde gegevens van de ADCP
metingen is dat de oppervlakten in deze tabel steeds behoorlijk variëren, terwijl
de waterstand in de zelfde tabel nauwelijks enkele centimeters varieert.
Daarom hebben we aan de hand van gemiddelde waterstand uit de berichten van
de FLOW-2000 ( in de korte periode dat iedere meting heeft geduurd ) en de
parameters in de FLOW-2000 de oppervlakte berekend die door de FLOW-2000 is
gebruikt voor het berekenen van de afvoer. Dan blijkt dat de oppervlakte welke
door de FLOW-2000 wordt gebruikt steeds behoorlijk lager is dan welke door de
ADCP meters wordt gebruikt.
De parameters voor de FLOW-2000 in Kanne-Noord zijn gebaseerd op
opmetingen van het profiel uit 2010. Uit deze metingen blijkt dat de maximale
diepte niet meer dan 5,25 m kan bedragen.
Dit terwijl de ADCP metingen steeds een hoger waarde geven voor de maximale
waterdiepte ( Gemiddeld 5,70 meter ).
Verder is het opmerkelijk dat de waterstanden zoals weergegeven in de tabel van
de ADCP metingen niet altijd in de buurt komen van de waterstanden zoals deze
voor de gegeven periode in de berichten van de FLOW-2000 voorkomen.
W. Lambrechts, ADM Kanne-Noord, ADCP Metingen 17 oktober 2013
Page 1 of 10
MEMO
Voor het maken van de onderstaande grafieken hebben we enkele kollommen aan
de tabel van de ADCP metingen toegevoegd.
H TAW FLOW =
Opp. FLOW =
FLOW-2000.
gemiddelde waterstand gedurende de meting met de ADCP.
uit de waterstand berekende oppervlakte gebruikt door de
Ϭ Opp. =
relatieve afwijking oppervlak van ADCP ten opzichte van
oppervlakte gebruikt door FLOW-2000.
Vmean * Opp = Oppervlakte van ADCP vermenigvuldigt met Vmean ADCP, is
meestal gelijk aan het getal Qcal van de ADCP.
SQ FLOW =
gemiddelde afvoer gedurende de meting met de ADCP.
ϬQ =
relatieve afwijking afvoer door ADCP ten opzichte van afvoer
berekend door FLOW-2000.
Vmean FLOW=
Afvoer FLOW-2000 gedeeld door oppervlakte gebruikt door de
FLOW-2000. Komt overeen met de Vmean van de ADCP
metingen.
Uncertainty relative = Percentuele afwijking van de Vmean op basis van de
nauwkeurigheid zoals deze door de fabrikant wordt opgegeven.
Voor de gebruikte type ADCP meters is dat ± 0,25% of ± 0,002
m/s. Afhankelijk wat groter is.
Uncertainty absolute = De onzekerheid in de Vmean waarmee volgens de opgave
van de fabrikant voor de ADCP meters moet worden gerekend.
Gezien de lage snelheden waarbij de metingen zijn uitgevoerd is
dat altijd ± 0,002 m/s
Conclusie:
De gevonden verschillen in de afvoer tussen de metingen van de ADM
Kanne-Noord en de ADCP metingen worden grotendeels veroorzaakt door
het grote verschil in de gebruikte oppervlakte voor het berekenen van de
afvoer.
Als gevolg van de lage stroomsnelheid bij de ADM Kanne-Noord moeten de
ADCP systemen opereren aan de grens van hun mogelijkheden.
De meetnauwkeurigheid van de te meten snelheid van het water door de
FLOW-2000 is voor alle snelheden gelijk en afhankelijk van de
nauwkeurigheid van de tijdmeting van de FLOW-2000 en de lengte van de
meetlijnen. Bij de ADM Kanne-Noord is deze altijd beter dan 0,25 mm/s.
W. Lambrechts, ADM Kanne-Noord, ADCP Metingen 17 oktober 2013
Page 2 of 10
MEMO
Algemeen.
Bij het vergelijken van de metingen door een FLOW-2000 of SURFLOW systeem
met een varende ADCP moet bij de beoordeling van de resultaten altijd worden
meegewogen dat :
•
•
•
Het volume waarin het FLOW-2000 of SURFLOW systeem de
watersnelheid meet meestal veel groter is dan het volume waarin de
ADCP de snelheidsmetingen uitvoert. Vooral bij lage snelheden kunnen
hierdoor verschillen ontstaan.
Bijvoorbeeld bij de ADM Kanne-Noord is de meetsectie voor de FLOW2000 ca. 100 meter lang.
Een FLOW-2000 of SURFLOW systeem gebruikt een absolute looptijd
methode voor het berekenen van de snelheid. Deze tijden worden
beïnvloed door de beweging van het water.
Dit in tegenstelling van de snelheidsmeting door een ADCP systeem, die
afhankelijk is van met het water mee bewegende zwevende deeltjes.
Deze zwevende deeltjes hebben zelden een gelijke snelheid als het
water.
Bij lage sterk variabele stroomsnelheden duurt het enige tijd voordat het
water waarin het FLOW-2000 of SURFLOW systeem de snelheid van het
water heeft gemeten aankomt bij de positie waar de metingen met het
ADCP systeem metingen verricht. Ook hierdoor kunnen verschillen
ontstaan tussen de metingen van de FLOW-2000 of SURFLOW systemen
en de metingen met een ADCP systeem.
W. Lambrechts, ADM Kanne-Noord, ADCP Metingen 17 oktober 2013
Page 3 of 10
MEMO
W. Lambrechts, ADM Kanne-Noord, ADCP Metingen 17 oktober 2013
Page 4 of 10
MEMO
W. Lambrechts, ADM Kanne-Noord, ADCP Metingen 17 oktober 2013
Page 5 of 10
MEMO
De onzekerheid van de meting 21, 38 – 51 en 52, 53 is erg groot!
W. Lambrechts, ADM Kanne-Noord, ADCP Metingen 17 oktober 2013
Page 6 of 10
MEMO
In bovenstaande grafiek zijn alle metingen waarbij de onzekerheid van de Vmean
ADCCP groter is dan 5% weg gelaten. Dan is er een veel betere
overeenstemming met de Vmean berekend uit de gegevens van de FLOW-2000.
Uitgezonderd de laatste meting van de sessie, meting 59.
W. Lambrechts, ADM Kanne-Noord, ADCP Metingen 17 oktober 2013
Page 7 of 10
MEMO
Opmerkelijk dat de waterstand verandering uit de ADCP metingen soms
tegengesteld is aan de waterstand verandering van de ADM Kanne-Noord. Vooral
meting 21 – 31, 44 – 49 en 50 – 55.
W. Lambrechts, ADM Kanne-Noord, ADCP Metingen 17 oktober 2013
Page 8 of 10
MEMO
Nr.
Datum
Start
Einde
H TAW
m
21
17/10/2013
7:49:31
7:51:42
60,15
H TAW Opp. m2 Opp.
m
m2
FLOW
FLOW
ϭ Opp.
%
Qcal
Vmean
m3/s
* Opp.
SQ
m3/s
ϭQ
Qcont Vmean
%
m3/s
FLOW
60,16
522,7 447,3
-17%
-13%
FLOW
2,6
12,21
-77%
12,2
12,2
10,20
20%
10,9
2,8
m/s
6,5
Vmean
m/s
Uncertainty
Relative
Absolute
m/s
FLOW
0,005
Uncertainty
0,027
40,00%
0,002
0,024
0,023
8,33%
0,002
22
17/10/2013
7:53:24
7:55:43
60,11
60,19
508,6 449,6
23
17/10/2013
7:53:51
7:56:50
60,12
60,18
496,5 449,3
-11%
13,5
13,4
12,53
8%
12,4
0,027
0,028
7,41%
0,002
24
17/10/2013
7:57:32
7:59:37
60,09
60,18
503,9 449,0
-12%
32,6
32,8
27,50
18%
28,0
0,065
0,061
3,08%
0,002
25
17/10/2013
7:57:37
7:59:44
60,09
60,18
528,5 449,0
-18%
34,5
34,4
27,50
25%
28,2
0,065
0,061
3,08%
0,002
26
17/10/2013
8:00:03
8:02:30
60,08
60,17
492,1 447,8
-10%
40,2
40,4
37,31
8%
36,9
0,082
0,083
2,44%
0,002
515,6 447,6
-15%
42,9
42,8
38,14
13%
38,4
0,083
0,085
2,41%
0,002
27
17/10/2013
8:00:31
8:02:44
60,08
60,17
28
17/10/2013
8:02:56
8:04:57
60,11
60,16
503,8 447,0
-13%
47,7
47,9
40,62
17%
39,8
0,095
0,091
2,11%
0,002
29
17/10/2013
8:03:31
8:04:49
60,11
60,16
505,0 447,0
-13%
55,2
55,0
43,80
26%
42,6
0,109
0,098
1,83%
0,002
30
17/10/2013
8:05:23
8:07:36
60,12
60,14
508,2 445,3
-14%
44,9
44,7
29,77
51%
40,9
0,088
0,067
2,27%
0,002
31
17/10/2013
8:05:25
8:07:56
60,13
60,14
486,3 445,1
-9%
44,0
43,8
37,94
16%
38,6
0,090
0,085
2,22%
0,002
32
17/10/2013
8:07:59
8:09:51
60,13
60,13
486,4 443,7
-10%
31,5
31,6
27,55
14%
27,6
0,065
0,062
3,08%
0,002
33
17/10/2013
8:08:15
8:10:11
60,13
60,13
488,2 443,6
-10%
32,8
32,7
27,67
19%
27,7
0,067
0,062
2,99%
0,002
-18%
25,7
25,5
17,75
45%
20,3
0,049
0,040
4,08%
0,002
34
17/10/2013
8:10:14
8:12:28
60,13
60,11
520,8 442,4
35
17/10/2013
8:12:52
8:14:49
60,13
60,10
484,3 441,2
-10%
21,4
21,3
22,31
-4%
22,7
0,044
0,051
4,55%
0,002
36
17/10/2013
8:13:50
8:16:49
60,11
60,10
495,4 441,4
-12%
29,1
29,2
21,84
33%
22,1
0,059
0,049
3,39%
0,002
37
17/10/2013
8:15:15
8:17:14
60,11
60,11
491,1 441,8
-11%
24,1
24,1
22,00
9%
22,4
0,049
0,050
4,08%
0,002
38
17/10/2013
8:17:00
8:19:37
60,11
60,10
437,2 441,5
1%
0,9
0,9
1,12
-17%
1,6
0,002
0,003
100,00%
0,002
39
17/10/2013
8:17:44
8:19:38
60,12
60,10
487,7 441,2
-11%
7,5
7,3
-2,25
-433%
-1,5
0,015
-0,005
13,33%
0,002
40
17/10/2013
8:20:06
8:22:34
60,12
60,11
491,3 441,9
-11%
-3,8
-3,9
-7,27
-48%
-7,2
-0,008
-0,016
-25,00%
0,002
41
17/10/2013
8:20:26
8:22:57
60,12
60,11
461,9 442,2
-4%
-5,8
-5,5
-6,81
-16%
-7,0
-0,012
-0,015
-16,67%
0,002
42
17/10/2013
8:23:07
8:25:21
60,13
60,12
451,8 442,8
-2%
1,8
1,8
1,21
48%
1,0
0,004
0,003
50,00%
0,002
43
17/10/2013
8:23:31
8:25:12
60,13
60,12
469,2 442,6
-6%
-3,6
-3,8
3,09
-217%
2,7
-0,008
0,007
-25,00%
0,002
W. Lambrechts, ADM Kanne-Noord, ADCP Metingen 17 oktober 2013
Page 9 of 10
MEMO
Nr.
Datum
Start
Einde
H TAW
m
H TAW Opp. m2 Opp.
m
FLOW
ϭ Opp.
m2
%
Qcal
Vmean
SQ
ϭQ
Qcont Vmean
m3/s
* Opp.
m3/s
%
m3/s
FLOW
FLOW
m/s
FLOW
Vmean Uncertainty
m/s
Relative
FLOW
Uncertainty
Absolute
m/s
44
17/10/2013
8:28:25
8:31:13
60,12
60,15
477,5 446,5
-7%
3,1
2,9
-2,41
-227%
-2,7
0,006
-0,005
33,33%
0,002
45
17/10/2013
8:28:34
8:30:42
60,12
60,15
507,4 446,1
-14%
-4,9
-5,1
-4,21
15%
-4,3
-0,010
-0,009
-20,00%
0,002
46
17/10/2013
8:31:25
8:33:41
60,12
60,17
478,3 448,0
-7%
-7,8
-7,7
-5,00
55%
-3,9
-0,016
-0,011
-12,50%
0,002
47
17/10/2013
8:31:17
8:33:48
60,12
60,17
520,0 448,0
-16%
5,5
5,7
-4,63
-219%
-3,6
0,011
-0,010
18,18%
0,002
48
17/10/2013
8:34:14
8:35:59
60,13
60,16
485,7 447,3
-9%
5,7
5,8
1,17
392%
1,7
0,012
0,003
16,67%
0,002
49
17/10/2013
8:38:10
8:40:53
60,14
60,16
533,0 446,6
-19%
4,4
4,3
1,74
151%
-0,7
0,008
0,004
25,00%
0,002
50
17/10/2013
9:33:07
9:35:06
60,07
60,14
472,1 445,5
-6%
3,7
3,8
7,69
-52%
1,6
0,008
0,017
25,00%
0,002
51
17/10/2013
9:36:14
9:38:25
60,06
60,15
535,3 445,8
-20%
9,0
9,1
7,73
16%
10,7
0,017
0,017
11,76%
0,002
52
17/10/2013
9:35:36
9:38:06
60,06
60,15
530,0 445,5
-19%
20,7
20,7
12,19
70%
14,3
0,039
0,027
5,13%
0,002
53
17/10/2013
9:39:01
9:41:01
60,07
60,18
505,2 448,9
-13%
0,6
0,5
-2,85
-122%
-0,7
0,001
-0,006
200,00%
0,002
54
17/10/2013
9:39:16
9:40:56
60,09
60,18
451,4 449,2
0%
3,1
3,2
-3,27
-194%
-2,2
0,007
-0,007
28,57%
0,002
55
17/10/2013
9:57:17
9:59:30
60,14
60,14
505,7 444,6
-14%
37,6
37,4
39,36
-5%
34,6
0,074
0,089
2,70%
0,002
56
17/10/2013
9:59:43
10:01:41
60,14
60,10
490,7 441,1
-11%
47,6
47,6
36,00
32%
35,7
0,097
0,082
2,06%
0,002
57
17/10/2013
10:01:33
10:04:00
60,13
60,07
497,0 438,0
-13%
49,7
49,7
43,07
15%
42,6
0,100
0,098
2,00%
0,002
58
17/10/2013
10:02:13
10:03:55
60,12
60,07
476,5 437,8
-9%
46,0
46,2
43,83
5%
42,9
0,097
0,100
2,06%
0,002
W. Lambrechts, ADM Kanne-Noord, ADCP Metingen 17 oktober 2013
Page 10 of 10
Waterbouwkundig Laboratorium
Flanders Hydraulics Research
Berchemlei 115
B-2140 Antwerp
Tel. +32 (0)3 224 60 35
Fax +32 (0)3 224 60 36
E-mail: [email protected]
www.watlab.be