CsI光電 面と GEMを用いたガスチェレンコフ検出器

Detector R&D:
J-PARC-E16
K. Ozawa (Univ. of Tokyo)
for the E16 collaboration
Condensates and Spectrum
We can link condensates and vector meson spectrum.
The relation is established robustly.
Vacuum
q
Vacuum
q
QCD sum rule
Experimental
Assume
results
Next Experiment
vector meson spectral function
Calculate amout of
mV
quark condensate
using QCD sum rule.
T.Hatsuda and S. Lee,
PRC 46 (1992) R34
Average of Imaginary
part of P(w2)
vector meson
spectral function
Model
Prediction
Calculation
Average
of
measured spectra
Mass

mV* Shift:
 B 


1


;  ) for
0.03
mmf = m
 0 (1 - /
0
0 

 =V 0.03
Spectrum
2008/12/06
Need large statics
Nagoya, K. Ozawa
p
2
New Spectrometer
E16 Spectrometer
KEK
5 times larger acceptance for pairs
Cope with 10 times larger beam intensity!!
2 times larger cross section
2008/12/06
Nagoya,
K. Ozawa statistics!!
Total, 100 times
higher
3
Major components
Prototype
is made and being tested
Magnet modification
GEM Tracker
Gas Cherenkov
for e-ID
Gas Cherenkov
for e-ID
EM Calorimeter
2008/12/06
Nagoya, K. Ozawa
4
GEM TRACKER
2008/12/06
Nagoya, K. Ozawa
5
Required Resolution
• Momentum and mass
resolution are evaluated
based on KEK knowledge.
KEK
300 mm
200 mm
100 mm
50 mm
– Position resolution:
• 300 mm for E325
• 50 mm, 100 mm, 200 mm, and
300 mm for J-PARC
Momentum Resolution
– Multiple scattering
[GeV/c]
• Radiation length of detectors
are increased for GEM foils
– Larger acceptance for J-PARC
J-PARC
To have the improved mass resolution,
Target Resolution is 100 mm
It can be achieved 0.7 mm pitch
and strip charge information.
2008/12/06
KEK
Nagoya, K. Ozawa
6
[mm]
mass res. v.s. position res.
GEM Tracker
Collaboration with KEK
• To cover large acceptance and
cope with high counting rate, 3
layers of GEM trackers are used.
• Similar to COMPASS detector
– Use 3 layers in magnetic field
Kapton
– Extend to large acceptance
• Challenge (d=50μm)
:
– Long term stability
– Mechanical support with low
radiation length
– Readout
Rate issue:
Cupper
2
5 kHz/mm is expected at J-PARC
(d=5μm)
with 700 mm pitch x 100mm height
COMPASS detector is working
Up to 25 kHz/mm2 (400 mm pitch)
GEM detector will work
2008/12/06
Nagoya, K. Ozawa
COMPASS detector
(NIM A535, 314)
7
GEM and Read out
• GEM foils made in Japan
(SciEnergy)
Collaboration with KEK
Relative Gain with 3 GEM foils
Japanese
• 2-D strip readout
configuration
Ar-CO2
CERN
NIM A425(1999)254
2008/12/06
Nagoya, K. Ozawa
8
R&D @ Tokyo
Purpose:
Develop a GEM tracker
Evaluate specifications
Position resolution
Efficiency
Rate dependence
Current Configuration:
3 GEM foils
p-10 gas
2-D strip
Both side
0.8 mm pitch
Copy of KEK’s
2008/12/06
Nagoya, K. Ozawa
9
Signals
TOP
We can see signals from both sides.
Signal from bottom surface is distorted.
Already known problem by KEK group.
Bottom
TOP1
Bottom1
Bottom2
TOP2
Strips on top surface
2008/12/06
Strips on bottom surface
Nagoya, K. Ozawa
10
Check with X-ray
Strip1
Strip2
Sum
Position
Fe-55 X-ray Source
Strip3
Position
Sum of 3 strips
distribution
is
looks reasonable
almost
reasonable.
distribution.
Beam test is done.
2008/12/06
Nagoya, K. Ozawa
Results of resolution
will be appeared soon.
11
GAS CHERENKOV
2008/12/06
Nagoya, K. Ozawa
12
Gas Cherenkov Detector
• Electron Identification using gas cherenkov
• Used for low momentum electron
– Mirror and PMT, traditionally
• Difficulty for Large acceptance
Requirement of large acceptance
at J-PARC E16 experiment
Photo Cathode +
GEM for amplification
No Mirror
Used @ KEK-PS E325
• CSI photo-cathod
– UV sensitive (6 eV, 200nm)
– High quantum efficiency
2008/12/06
Nagoya, K. Ozawa
13
Measurements of Q.E.
Existing data by
Weizmann Inst.
• We got a consistent result with existing data.
• Based on this measurements, the number of photoelectron with 84 cm long radiator is estimated as 65.
2008/12/06
Nagoya, K. Ozawa
14
Old beam test @ Hiroshima
• Operation
1*1cm
Readout Pad
5x5 used
– Pure CF4
(cosθc=0.035)
– CsI GEM
• 150V
– Other GEM
• 490V (~104)
Light
Shield
– Water ~ 1ppm
• Inverse field
• Light shade ON
– dE/dx (1mm)
• Light shade OFF
– dE/dx (1mm) +
Light
2008/12/06
Electrons from ionization
Nagoya, K. Ozawa
15
Results
Arbitrary Unit
Inverse field, light shield on, dE/dx (1mm) Only
Inverse field, light shield off, dE/dx (1mm) + Light
Clear signal for
energy loss
7 fc
10 fc
Small difference, statistically
It can be Cherenkov origin.
New R&D is underway at RIKEN.
Results will be appeared soon.
2008/12/06
0
Ozawa
20Nagoya, K.40
60
80
16
[Charge]
Summary
• For J-PARC E16, a GEM based spectrometer is
proposed to cope with high interaction rate and
have large acceptance.
• R&D has started for J-PARC at Tokyo and RIKEN.
GEM tracker with 2-D strip read out is being
developed. First brief result of R&D is appeared.
• Cherenkov counter using CSI photocathode and
GEM readout is the essential part to extend the
acceptance. R&D is on-going.
2008/12/06
Nagoya, K. Ozawa
17
Back up
Issue: counting Rate
• Interaction rate is 106 Hz at KEK (x10 @J-PARC)
• However, beam halo can not be ignored
• For example, actual condition at KEK is following.
– 350 kHz at the most forward cell of Drift Chamber
• At radius of 200 mm and the horizontal angle of 6°
• 3.5mm width and 220 mm height
– Mostly from beam halo
• Extrapolate to J-PARC
–
–
–
–
10 times higher beam intensity
shorter beam-extraction duration
3.5 MHz is expected.
10 times finer segments are required
• 0.7 mm pitch x 100mm height
That’s the main issue for spectrometer design.
We have to develop the detector which cope with 10 times larger rate.
2008/12/06
Nagoya, K. Ozawa
19
Detectors in high counting
• MWPC limitation
– Wire spacing: 1~2 mm
– Gain dropping @ high rate
• Micro strip gas chamber
– Discharge problem
• Micromegas
MWPC
– Another candidate
• GEM
– Flat gain up to 105 Hz/mm2
– I like flexibility of configuration
– Good characteristics of signal
• Signal is generated by electron
• Not by ion
• No ion tail and pole cancellation
electronics
2008/12/06
I took these
104 105
GEM
Nagoya,
K. Ozawa
ideas and figures
from
F. Sauli’s presentation at XIV 20
GIORNATE DI STUDIO SUI RIVELATORI Villa Gualino 10-13 Febbraio 2004
What can be achieved?
Pb
f
f
Modified f
f
f
f
ff f
f
f from
Proton
[GeV/c2]
High
resolution
Invariant
mass in
medium
Nagoya, K. Ozawa
calculate quark condensate
2008/12/06
21
Pictures from PHENIX
signal electron
partner
positron
needed for
rejection
In PHENIX IR
Globe box
Evaporate machine
2008/12/06
Nagoya, K. Ozawa
22
CSI photo cathode
• Transmissive type is used
– Suitable with GEM
– Relatively high quantum
efficiency
– Low photon feedback
Transmissive
By Weitzman
Vapor deposition on GEM
By Hamamatsu
5
10
CSI Q. E.
2008/12/06
15
[eV]
Nagoya, K. Ozawa
CsI
Au
Ni
Cu
Kapton
Cu
23
In reality
2008/12/06
Nagoya, K. Ozawa
24