GETTING STARTED GUIDE NI PXIe-6544/6545/6547/6548 100/200 MHz Digital Waveform Generator/Analyzer Note Before you begin, install and configure your chassis and controller. This document explains how to install, configure, and test the NI PXIe-6544/6545/6547/6548 (NI 6544/6545/6547/6548). The NI 6544/6545/6547/6548 is a digital waveform generator/ analyzer that features 32 bidirectional channels clocked at a maximum of 200 MHz. To access NI 6544/6545/6547/6548 documentation, go to Start»All Programs»National Instruments»NI-HSDIO»Documentation. Note The protection provided by the NI 6544/6545/6547/6548 may be impaired if it is used in a manner not described in this document. Hot Surface If the NI 6544/6545/6547/6548 has been in use, the device may exceed safe handling temperatures and may cause discomfort. Allow the NI 6544/6545/6547/6548 to cool before touching the device or removing the device from the chassis. Contents Electromagnetic Compatibility Guidelines............................................................................... 2 Verifying the System Requirements..........................................................................................2 Unpacking the Kit..................................................................................................................... 3 Kit Contents...................................................................................................................... 3 Preparing the Environment....................................................................................................... 4 PXI Express Modules........................................................................................................4 Installing the Software.............................................................................................................. 4 NI Script Editor................................................................................................................. 4 NI Digital Waveform Editor..............................................................................................5 Installing the NI 6544/6545/6547/6548.................................................................................... 5 Connecting Signals................................................................................................................... 6 NI 6544/6545/6547/6548 Front Panels............................................................................. 6 Cabling Considerations..................................................................................................... 9 Connecting Accessories.................................................................................................. 10 Connecting a Custom Accessory.................................................................................... 12 Wiring Considerations for Common Applications..........................................................12 Configuring the NI 6544/6545/6547/6548 in MAX............................................................... 13 Using the Test Panel to Generate Digital Data........................................................................14 Using the Test Panel to Acquire Digital Data......................................................................... 15 Programming the NI-HSDIO.................................................................................................. 16 NI-HSDIO Examples...................................................................................................... 16 Troubleshooting...................................................................................................................... 17 What Should I Do if the NI 6544/6545/6547/6548 Doesn't Appear in MAX?...............17 What Should I Do if the Module Fails the Self-Test?.....................................................18 Why Is the ACCESS LED Off When the Chassis is On?...............................................18 Where to Go Next................................................................................................................... 18 Worldwide Support and Services............................................................................................ 19 Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Caution To ensure the specified EMC performance when connecting a cable to the Digital Data and Control (DDC) connector, install two snap-on, ferrite beads (NI part number 711627-01) included in the shipping kit onto the cable. Place one ferrite bead at each end of the cable, as close to the connector as practical. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Do not use unshielded cables or accessories unless they are installed in a shielded enclosure with properly designed and shielded input/ output ports and connected to the product using a shielded cable. If unshielded cables or accessories are not properly installed and shielded, the EMC specifications for the product are no longer guaranteed. Note To ensure the specified EMC performance, the length of all I/O cables must be no longer than 3 m (10 ft). Verifying the System Requirements To use the NI-HSDIO instrument driver, your system must meet certain requirements. Refer to the product readme, which is available on the driver software media or online at ni.com/manuals, for more information about minimum system requirements, recommended system, and supported application development environments (ADEs). 2 | ni.com | NI PXIe-6544/6545/6547/6548 Getting Started Guide Unpacking the Kit 1. 2. Caution To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis. Touch the antistatic package to a metal part of the computer chassis. Remove the device from the package and inspect the device for loose components or any other sign of damage. Caution Never touch the exposed pins of connectors. Note Do not install a device if it appears damaged in any way. 3. Unpack any other items and documentation from the kit. Store the device in the antistatic package when the device is not in use. Kit Contents The kit contains the following items: • NI-HSDIO instrument driver software media, which installs the following: – NI-HSDIO driver – NI Script Editor – NI Digital Waveform Generator/Analyzer Help – NI PXIe-6544/6545/6547/6548 Getting Started Guide (this document) • NI Digital Waveform Editor software media • NI 6544/6545/6547/6548 device • snap-on ferrite beads (2x) (NI part number 711627-01) • Using Ferrites to Reduce High-Frequency Emissions Note to Users document NI PXIe-6544/6545/6547/6548 Getting Started Guide | © National Instruments | 3 Preparing the Environment Ensure that the environment in which you are using the NI 6544/6545/6547/6548 meets the following specifications: PXI Express Modules Operating Environment .................................................................... Ambient temperature range 0 °C to 55 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.) Relative .................................................................... humidity range 10% to 90%, noncondensing (Tested in accordance with IEC 60068-2-56.) Maximum altitude ............................................................................ 2,000 m (800 mbar) (at 25 °C ambient temperature) Pollution Degree ............................................................................ 2 Indoor use only. Installing the Software You must be an Administrator to install NI software on your computer. 1. Install an ADE, such as LabVIEW or LabWindows™/CVI™. 2. Insert the driver software media into your computer. The installer should open automatically. If the installation window does not appear, navigate to the drive, double-click it, and double-click autorun.exe. 3. Follow the instructions in the installation prompts. Note Windows users may see access and security messages during installation. Accept the prompts to complete the installation. 4. When the installer completes, select Restart in the dialog box that prompts you to restart, shut down, or restart later. NI Script Editor The NI Script Editor helps you develop linking and looping waveform generation operations. The NI Script Editor is installed when you install NI-HSDIO. For more information, launch the NI Script Editor and select Help»NI Script Editor Help from the toolbar. 4 | ni.com | NI PXIe-6544/6545/6547/6548 Getting Started Guide NI Digital Waveform Editor The NI Digital Waveform Editor (NI DWE) allows you to create, edit, and import digital test vectors. Note To use the NI DWE, install it after you install NI-HSDIO. Installing the NI 6544/6545/6547/6548 Caution To prevent damage to the device caused by ESD or contamination, handle 1. the device using the edges or the metal bracket. Ensure the AC power source is connected to the chassis before installing the modules. The AC power cord grounds the chassis and protects it from electrical damage while you install the modules. 2. Power off the chassis. 3. Inspect the slot pins on the chassis backplane for any bends or damage prior to installation. Do not install a module if the backplane is damaged. 4. Remove the black plastic connectors from all the captive screws on the module front panel. 5. Identify a supported slot in the chassis. The following figure shows the symbols that indicate the slot types. Figure 1. Chassis Compatibility Symbols NI PXIe-1062Q 1 1. PXI Express System Controller Slot 2. PXI Peripheral Slot 3. PXI Express Hybrid Peripheral Slot 2 3 5 4 4. PXI Express System Timing Slot 5. PXI Express Peripheral Slot NI 6544/6545/6547/6548 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. 6. Touch any metal part of the chassis to discharge static electricity. 7. Ensure that the ejector handle is in the unlatched (downward) position. 8. Place the module edges into the module guides at the top and bottom of the chassis. Slide the device into the slot until it is fully inserted. NI PXIe-6544/6545/6547/6548 Getting Started Guide | © National Instruments | 5 Figure 2. Module Installation 1 NI PX Ie -10 75 2 3 1. Chassis 2. Hardware Module 3. Ejector Handle in Down (Unlatched) Position 9. Latch the module in place by pulling up on the ejector handle. 10. Secure the device front panel to the chassis using the front-panel mounting screws. Note Tightening the top and bottom mounting screws increases mechanical stability and also electrically connects the front panel to the chassis, which can improve the signal quality and electromagnetic performance. 11. Cover all empty slots using filler panels or slot blockers to maximize cooling air flow. 12. Power on the chassis. Connecting Signals NI 6544/6545/6547/6548 Front Panels The NI 6544/6545/6547/6548 front panel exposes the following connections: • Three SMA connectors named CLK IN, PFI 0, and CLK OUT • One 68-pin VHDCI connector named DIGITAL DATA & CONTROL, or DDC 6 | ni.com | NI PXIe-6544/6545/6547/6548 Getting Started Guide Figure 3. NI 6544/6545/6547/6548 Front Panel with VHDCI Connector Pinout 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 DIO 30 GND DIO 28 GND DIO 26 GND DIO 24 GND DIO 22 GND DIO 20 GND DIO 18 GND DIO 16 GND DIO 14 RESERVED DIO 12 GND DIO 10 GND DIO 8 GND DIO 6 RESERVED DIO 4 GND DIO 2 PFI 2 DIO 0 GND STROBE GND NI PXIe-654X ACCESS ACTIVE CLK IN PFI 0 CLK OUT DIGITAL DATA & CONTROL DIO 31 GND DIO 29 GND DIO 27 GND DIO 25 RESERVED DIO 23 GND DIO 21 GND DIO 19 GND DIO 17 GND DIO 15 GND DIO 13 GND DIO 11 GND DIO 9 GND DIO 7 PFI 1 DIO 5 GND DIO 3 PFI 3 DIO 1 GND DDC CLK OUT GND Table 1. NI 6544/6545/6547/6548 DDC Connector Pins Pins Signal Name Signal Type Signal Description 33 DDC_CLK OUT Control Output terminal for the exported Sample Clock. 67 Strobe Control Terminal for the external Sample clock source, which can be used for dynamic acquisition. NI PXIe-6544/6545/6547/6548 Getting Started Guide | © National Instruments | 7 Table 1. NI 6544/6545/6547/6548 DDC Connector Pins (Continued) Pins Signal Name Signal Type Signal Description 1, 3, 5, 7, 9, 11, 13, 15, 17, 19, 21, 23, 25, 27, 29, 31, 35, 37, 39, 41, 43, 45, 47, 49, 51, 53, 55, 57, 59, 61, 63, 65 DIO <0..31> Data Bidirectional digital I/O data channels 0 through 31. 26, 30, 64 Programmable Function Interface (PFI) <1..3> Control Input terminals to the device for external triggers, or output terminals from the device for events. 2, 4, 6, 10, 12, 14, 16, 18, 20, 22, 24, 28, 32, 34, 36, 38, 40, 42, 44, 46, 48, 50, 54, 56, 58, 62, 66 GND Ground Ground reference for signals. 8, 52, 60 RESERVED N/A Terminals reserved for future use. Do not connect to these pins. Table 2. NI 6544/6545/6547/6548 SMA Connectors Connector Signal Name Signal Type Description CLK IN Reference Clock Input Control Terminal for the external Reference clock used for the PLL or for the external Sample clock used for dynamic generation and/or acquisition. PFI 0 PFI 0 Control Single-ended input terminals to the device for static I/O, for external triggers, or for output terminals from the device for events. Refer to the device specifications for signal voltage levels. Control Terminal for the exported PLL Reference clock or the exported Sample clock. CLK OUT Reference Clock Output 8 | ni.com | NI PXIe-6544/6545/6547/6548 Getting Started Guide Table 3. ACTIVE LED Indicators Color Off Indications Device not armed and not triggered. Amber Device armed and awaiting Start Trigger. If performing a dynamic acquisition operation, the device may be acquiring pretrigger samples. Green Device received Start Trigger. Red Error condition. Table 4. ACCESS LED Indicators Color Off Indications Device not ready. Amber Device being accessed by software. Green Device ready to be programmed Red Running the niHSDIO Self Test VI or calling the niHSDIO_self_test function produced a failure. Cabling Considerations Cables for DDC connector Caution To ensure the specified EMC performance when connecting a cable to the Digital Data and Control (DDC) connector, install the two snap-on, ferrite beads (NI part number 711627-01)included in the shipping kit onto the cable. Place one ferrite bead at each end of the cable, as close to the connector as practical. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Do not use unshielded cables or accessories unless they are installed in a shielded enclosure with properly designed and shielded input/ output ports and connected to the product using a shielded cable. If unshielded cables or accessories are not properly installed and shielded, the EMC specifications for the product are no longer guaranteed. Use one of the following cables for connections to the Digital Data and Control (DDC) connector on the NI 6544/6545/6547/6548. • NI 6544/6545/6547/6548 shielded single-ended cable with individual microcoaxial 50 Ω lines for each signal • NI 6544/6545/6547/6548 unshielded single-ended digital cable NI PXIe-6544/6545/6547/6548 Getting Started Guide | © National Instruments | 9 • NI 6544/6545/6547/6548 shielded low-leakage cable. Use this cable if current leakage is a concern. NI 6544/6545/6547/6548 shielded flying lead cable Figure 4. Single-Ended Flying Lead Cable Parts Locator Diagram • 1 2 3 1. Lead Pairs 2. Removable Sleeving 3. 68-Pin VHDCI Connector Note Always terminate cables properly to avoid improper measurements caused by signal reflections, overshoot, and undershoot. Refer to the NI Digital Waveform Generator/Analyzer Help for more information about signal termination. Connecting Accessories • Connect the NI CB-2162 single-ended digital I/O accessory to access the DDC connector on the device, to terminate the DIO channels on the device, or to develop a platform for prototyping circuits and testing DUTs. Refer to the following figure to the connect the NI CB-2162 to the NI 6544/6545/6547/6548. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Do not use unshielded cables or accessories unless they are installed in a shielded enclosure with properly designed and shielded input/output ports and connected to the product using a 10 | ni.com | NI PXIe-6544/6545/6547/6548 Getting Started Guide shielded cable. If unshielded cables or accessories are not properly installed and shielded, the EMC specifications for the product are no longer guaranteed. Figure 5. Connecting the NI CB-2162 and an NI-HSDIO device 2 NI PXI-6551 50 MHz Digital I/O ACCESS ACTIVE CLK IN PFI 0 DIGITAL DATA & CONTROL CLK OUT 1 3 1. Chassis with NI-HSDIO device 2. NI SHC68-C68-D4 Cable 3. NI CB-2162 Accessory • Connect the NI SMB-2163 accessory to the NI 6544/6545/6547/6548 in order to interface to other devices for testing and debugging. Refer to the following figure to the connect the NI SMB-2163 to the NI 6544/6545/6547/6548. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Do not use unshielded cables or accessories unless they are installed in a shielded enclosure with properly designed and shielded input/output ports and connected to the product using a NI PXIe-6544/6545/6547/6548 Getting Started Guide | © National Instruments | 11 shielded cable. If unshielded cables or accessories are not properly installed and shielded, the EMC specifications for the product are no longer guaranteed. Figure 6. Connecting the NI SMB-2163 and an NI-HSDIO device NI PXI-6551 50 MHz Digital I/O ACCESS ACTIVE CLK IN PFI 0 DIGIDIGITAL DATA & CONTROL CLK OUT 1 2 3 1. Chassis with NI-HSDIO device 2. NI SMB-2163 Accessory 3. NI SHC68-C68-D4 Cable Connecting a Custom Accessory Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Do not use unshielded cables or accessories unless they are installed in a shielded enclosure with properly designed and shielded input/ output ports and connected to the product using a shielded cable. If unshielded cables or accessories are not properly installed and shielded, the EMC specifications for the product are no longer guaranteed. Many common NI digital waveform generator/analyzer applications require you to create a custom accessory to access the signals of your device under test (DUT). To connect a custom accessory to the VHDCI DDC connector on the NI 6544/6545/6547/6548, purchase a mating connector for the VHDCI cable from NI. For more information, refer to the Interfacing to the NI Digital Waveform Generator/ Analyzer using the VHDCI Connector application note, available by entering the info code rdinwa at ni.com/info. Wiring Considerations for Common Applications Dynamic Generation Wiring Considerations You may need additional parallel termination resistance at the destination for optimal signal quality during dynamic generation, depending on the loading of the device under test (DUT). Refer to the NI Digital Waveform Generator/Analyzer Help for information about signal 12 | ni.com | NI PXIe-6544/6545/6547/6548 Getting Started Guide termination. The following figure shows how the NI 6544/6545/6547/6548 generates data through a matched impedance system. Figure 7. Dynamic Generation Functional Diagram RS RT 3 2 1 4 3. 50 Ω cable 4. Device under test (DUT) 1. NI-HSDIO device 2. 50 Ω source impedance (Rs) Dynamic Acquisition Wiring Considerations During dynamic acquisition, the device under test (DUT) generating the signals must have a matched source impedance as close to 50 Ω as possible in order to minimize signal reflections and maintain optimal signal quality. The following figure shows how the NI 6544/6545/6547/6548 acquires data through a matched impedance system. Refer to the specifications document for your device for supported input impedances (RT). Figure 8. Dynamic Acquisition Functional Diagram RT RS 2 1 3 4 1. NI-HSDIO device 2. 50 Ω cable 3. 50 Ω source impedance (Rs) 4. Device under test (DUT) Configuring the NI 6544/6545/6547/6548 in MAX Use Measurement & Automation Explorer (MAX) to configure your National Instruments hardware. MAX informs other programs about which devices reside in the system and how they are configured. MAX is automatically installed with NI-HSDIO. 1. Launch MAX. NI PXIe-6544/6545/6547/6548 Getting Started Guide | © National Instruments | 13 2. In the configuration tree, double-click Devices and Interfaces to see the list of installed devices. Note If you are using the NI 6544/6545/6547/6548 with the LabVIEW RealTime Module, expand Remote Systems. Find your target IP address or name, expand it, and then expand Devices and Interfaces. Expand your Chassis tree item. 3. MAX lists all devices installed in the chassis. Your default device names may vary. Note If you do not see your device listed, press <F5> to refresh the list of installed devices. If the device is still not listed, power off the system, ensure the device is correctly installed, and restart. Record the device identifier MAX assigns to the hardware. Use this identifier when programming the NI 6544/6545/6547/6548. Self-test the device by selecting the device in the configuration tree and clicking Self-Test in the MAX toolbar. 4. 5. The MAX self-test performs a basic verification of hardware resources. Using the Test Panel to Generate Digital Data To verify your device configuration, use the device test panel in MAX to generate simple digital data using the NI 6544/6545/6547/6548. 1. Remove any signal connections to the device. 2. Right-click the device under the appropriate Chassis, and select Test Panels. 3. Select the Dynamic tab on the side of the pane. 4. Click Select All to select all of your channels. The digital waveform now appears in the graph. 5. Enter the frequency in the Clock Frequency control, located on the left side of the test panel. 6. Enter values for the generation and acquisition voltages in the controls below the Clock Frequency control. You can enter High and Low values to create your own custom levels for the device. 7. Choose a fill pattern. The following figure shows the pattern control and the first few signals in the window. Note When generating a Marching Ones or Marching Zeroes waveform, make the waveform size a multiple of the number of selected channels. 8. 14 Click Play to generate the waveform shown in the graph on the selected channels. The default generation option is Continuous, but you can toggle this setting using the control below the graph. | ni.com | NI PXIe-6544/6545/6547/6548 Getting Started Guide Because the data channels on the NI 6544/6545/6547/6548 are bidirectional, while the data is being continuously generated on all of the channels, as in the previous step, you can acquire the data being generated. Note Refer to the specifications document for information about the setup and hold times and propagation delays associated with generation operations of the device. At some frequencies, generating data on the same channels when no cable is attached to the DIGITAL DATA & CONTROL (DDC) connector violates these timing parameters and results in incorrectly sampled data. For information, refer to the NI Digital Waveform Generator/Analyzer Help. Using the Test Panel to Acquire Digital Data To verify your device configuration, use the device test panel in MAX to acquire simple digital data using the NI 6544/6545/6547/6548. 1. Click the Acquisition tab. 2. Click Play. The device acquires the digital data that you generated in the previous steps, and the data is displayed on the graph. 3. Click Close when you are finished. NI PXIe-6544/6545/6547/6548 Getting Started Guide | © National Instruments | 15 Programming the NI-HSDIO You can generate or acquire data using the NI-HSDIO instrument driver to program the NI 6544/6545/6547/6548 in the supported ADE of your choice. Table 5. NI 6544/6545/6547/6548 Programming Options Application Programming Interface (API) NI-HSDIO Instrument Driver Location Description LabVIEW—Available on the LabVIEW Functions palette at Measurement I/O»NI-HSDIO. NI-HSDIO configures and operates the device hardware and performs basic waveform generation and acquisition using C or LabWindows/CVI—Available LabVIEW VIs or at Program Files»IVI LabWindows/CVI functions. Foundation»IVI»Drivers» niHSDIO. Microsoft Visual C/C++—Use examples located in the <NIDocDir>\NI-HSDIO \examples directory, where <NIDocDir> is one of the following directories: • Windows 8/7/Vista—Users \Public\Documents \National Instruments • Windows XP—Documents and Settings\All Users\Shared Documents\National Instruments You can modify an NI-HSDIO C example to create an application with Microsoft Visual C/C++. Copy an NI-HSDIO example to copy required project settings for include paths and library files. Alternatively, refer to the Creating an Application with Microsoft Visual C and C++ topic of the NI Digital Waveform Generator/ Analyzer Help to manually add all required include and library files to your project. NI-HSDIO Examples To locate programming examples, refer to the following table. 16 | ni.com | NI PXIe-6544/6545/6547/6548 Getting Started Guide Table 6. NI-HSDIO Example Locations Application Development Environment (ADE) Location LabVIEW or LabWindows/CVI Within LabVIEW or LabWindows/CVI, select Help»Find Examples, and navigate to Hardware Input and Output» Modular Instruments. ANSI C Available at <NIDocDir>\NI-HSDIO\examples\ directory, where <NIDocDir> is one of the following directories: • Windows 8/7/Vista—Users\Public\Public Documents\National Instruments • Windows XP—Documents and Settings\All Users\Shared Documents\National Instruments Troubleshooting If an issue persists after you complete a troubleshooting procedure, contact NI technical support or visit ni.com/support. What Should I Do if the NI 6544/6545/6547/6548 Doesn't Appear in MAX? 1. 2. 3. 4. In the MAX configuration tree, click Devices and Interfaces. Expand the Chassis tree to see the list of installed devices, and press <F5> to refresh the list. If the module is still not listed, power off the system, ensure that all hardware is correctly installed, and restart the system. Navigate to the Device Manager. Operating System Description 5. Windows 8 Right-click the Start screen, and select All apps»Control Panel» Hardware and Sound»Device Manager. Windows 7 Select Start»Control Panel»Device Manager. Windows Vista Select Start»Control Panel»System and Maintenance»Device Manager. Windows XP Select Start»Control Panel»System»Hardware»Device Manager. If you are using a PXI controller, verify that a National Instruments entry appears in the system device list. Reinstall NI-HSDIO and the device if error conditions appear in the list. If you are using an MXI controller, right-click PCI-to-PCI Bridge, and select Properties from the shortcut menu to verify that the bridge is enabled. NI PXIe-6544/6545/6547/6548 Getting Started Guide | © National Instruments | 17 What Should I Do if the Module Fails the Self-Test? 1. Restart the system. 2. Launch MAX, and perform the self-test again. 3. Power off the chassis. 4. Reinstall the failed module in a different slot. 5. Power on the chassis. 6. Perform the self-test again. Why Is the ACCESS LED Off When the Chassis is On? The LEDs may not illuminate until the device has been configured in MAX. Before proceeding, verify that the NI 6544/6545/6547/6548 appears in MAX. If the ACCESS LED fails to illuminate after you power on the PXI Express chassis, a problem may exist with the PXI Express power rails, a hardware module, or the LED. 1. Caution Apply external signals only while the NI 6544/6545/6547/6548 is powered on. Applying external signals while the device is powered off may cause damage. Disconnect any signals from the PXI Express module front panels. 2. Remove any front panel connections from the NI 6544/6545/6547/6548. 3. Power off the PXI Express chassis. 4. Remove the module from the PXI Express chassis and inspect it for damage. Do not reinstall a damaged device. 5. Install the module in a different PXI Express chassis slot from which you removed it. 6. Power on the PXI Express chassis. 7. Verify that the device appears in MAX. 8. Reset the device in MAX and perform a self-test. If the ACCESS LED still fails to illuminate and failures continue, contact NI technical support or visit ni.com/support. Where to Go Next The following figure describes additional documentation and resources as you develop an application with the NI 6544/6545/6547/6548. 18 | ni.com | NI PXIe-6544/6545/6547/6548 Getting Started Guide Located in the hardware kit Located online at ni.com/manuals Located using the NI Example Finder EXPLORE LEARN CREATE the application development environment (ADE) for your application. about hardware features or review device specifications. custom applications within an application programming interface (API). Getting Started with LabVIEW specifications for your device* Getting Started with LabWindows/CVI NI High-Speed Digital Waveform Generator/ Analyzer Help* NI-HSDIO Instrument Driver NI-HSDIO Examples* NI High-Speed Digital Waveform Generator/ Analyzer Help* DISCOVER more about your products through ni.com. Support ni.com/support High-Speed Digital I/O ni.com/highspeeddigitalio/ Services ni.com/services NI Community ni.com/community *This item is also installed with the driver software. Worldwide Support and Services The National Instruments website is your complete resource for technical support. At ni.com/ support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your National Instruments product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer’s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or NI PXIe-6544/6545/6547/6548 Getting Started Guide | © National Instruments | 19 dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2004—2015 National Instruments. All rights reserved. 375089A-01 Jun15 スタートアップガイド NI PXIe-6544/6545/6547/6548 100/200 MHz デジタル波形発生器/アナライザ メモ 作業を開始する前に、シャーシおよびコントローラを取り付けて構成 します。 このドキュメントでは、NI PXIe-6544/6545/6547/6548(NI 6544/6545/6547/6548)の取 り付け、構成、およびテスト方法について説明しています。 NI 6544/6545/6547/6548 は、最大 200 MHz にクロックされた 32 の双方向チャンネルを装備したデジタル波形 発生器/アナライザです。 NI 6544/6545/6547/6548 のドキュメントにアクセスするには、 スタート→すべてのプ ログラム→National Instruments→NI-HSDIO→ドキュメントを参照してください。 メモ ドキュメントに記載されている手順以外の方法で使用した場合、 NI 6544/6545/6547/6548 に装備されている保護機能が正常に動作しない場合 があります。 熱面 NI 6544/6545/6547/6548 が使用されていた場合、デバイスが安全な取扱 温度を超えて不快感を生じさせる場合があります。デバイスに触れたり、デ バイスをシャーシから取り外す前に、NI 6544/6545/6547/6548 を十分に冷却し てください。 目次 電磁両立性ガイドライン.................................................................................................................................. 2 システム要件を確認する.................................................................................................................................. 3 キットを梱包から取り出す............................................................................................................................. 3 キットの内容..................................................................................................................................................3 環境を整える............................................................................................................................................................4 PXI Express モジュール..............................................................................................................................4 ソフトウェアをインストールする.............................................................................................................. 4 NI Script Editor.................................................................................................................................................4 NI Digital Waveform Editor.......................................................................................................................5 NI 6544/6545/6547/6548 を取り付ける...................................................................................................... 5 信号を接続する.......................................................................................................................................................6 NI 6544/6545/6547/6548 フロントパネル....................................................................................... 6 ケーブル接続に関する注意事項......................................................................................................... 9 アクセサリを接続する........................................................................................................................... 10 カスタムアクセサリを接続する.......................................................................................................12 一般的なアプリケーションの配線に関する注意事項......................................................... 12 NI 6544/6545/6547/6548 を MAX で構成する....................................................................................... 13 テストパネルを使用してデジタルデータを生成する................................................................... 14 テストパネルを使用してデジタルデータを集録する................................................................... 15 NI-HSDIO をプログラミングする................................................................................................................ 16 NI-HSDIO サンプル.....................................................................................................................................16 トラブルシューティング................................................................................................................................ 17 MAX で NI 6544/6545/6547/6548 が表示されない場合.........................................................17 モジュールがセルフテストで不合格になる............................................................................. 18 シャーシの電源を投入しても ACCESS LED が点灯しない................................................18 その他のガイドとヘルプ................................................................................................................................ 19 世界各地でのサポートおよびサービス..................................................................................................19 電磁両立性ガイドライン この製品は、製品仕様書に記載された電磁両立性(EMC)の規制基準および制限に基 づいて所定の試験が実施され、これらに適合するものと認定されています。 これらの 基準および制限は、製品を意図された動作電磁環境で操作する場合に、有害な電磁妨 害から保護するために設けられました。 この製品は、工場での使用を意図して設計されています。 ただし、この製品が周辺デ バイスまたは試験対象に接続されている場合、または住宅地域もしくは商業地域で使 用されている場合、設置方法によっては有害な電磁妨害が発生する場合があります。 製品によるラジオおよびテレビ受信への電磁妨害、そして許容できない性能低下を最 小限に抑えるには、製品ドキュメントの手順に厳密に従って取り付け、使用してくだ さい。 また、ナショナルインスツルメンツによって明示的に許可されていない製品への変更 および修正は、地域の取締規則下で製品を操作するユーザの権利を無効にする可能性 があります。 注意 デジタルデータおよび制御(DDC)コネクタにケーブルが接続すると きに、指定された EMC のパフォーマンスを確保するには、出荷キットに同梱 されている 2 つのフェライトビーズ(NI 製品番号 711627-01)を取り付けま す。ケーブルの両端のコネクタにできるだけ近い位置にそれぞれフェライト ビーズを 1 つ配置します。 注意 指定された EMC のパフォーマンスを確保するには、シールドケーブル およびアクセサリを必ず使用してください。非シールドケーブルまたはアク セサリを使用する場合は、適切に設計されたシールド付き入力/出力ポートが 装備され、シールドケーブルで製品に接続されたシールドケースに取り付け てください。非シールドケーブルまたはアクセサリが適切に取り付けおよび シールドされていない場合、この製品の EMC 仕様は保証されません。 2 | ni.com | NI PXIe-6544/6545/6547/6548 スタートアップガイド メモ 指定された EMC のパフォーマンスを確保するには、すべての I/O ケー ブルの長さを 3 m(10 ft)未満にする必要があります。 システム要件を確認する NI-HSDIO 計測器ドライバを使用するには、特定の要件を満たすシステムが必要です。 最低システム要件、推奨要件、サポートされている開発環境(ADE)については、 ドライバソフトウェアメディアに含まれる、または ni.com/manuals から入手で きる製品の Readme を参照してください。 キットを梱包から取り出す 1. 2. 注意 デバイスに破損をもたらす静電気放電(ESD)を防ぐために、接地スト ラップを使用したり、コンピュータシャーシなどの接地された物体に触れて、 身体の静電気を逃がしてください。 静電気防止用パッケージをコンピュータシャーシの金属部分に接触させます。 デバイスを箱から取り出し、部品がゆるんでいないかどうか、またはその他の破 損箇所がないかどうかを調べます。 注意 露出しているコネクタピンには絶対に触れないでください。 メモ デバイスが少しでも破損しているように見える場合は、取り付け ないでください。 3. その他の品目および付属文書をキットから取り出します。 デバイスを使用しないときは、静電気防止用パッケージに入れて保管してください。 キットの内容 キットには、以下のものが含まれています。 • NI-HSDIO 計測器ドライバソフトウェアメディア。次のものをインストールしま す。 – NI-HSDIO ドライバ – NI Script Editor • • • • – NI デジタル波形発生器/アナライザヘルプ – NI PXIe-6544/6545/6547/6548 スタートアップガイド(このドキュメント) NI Digital Waveform Editor ソフトウェアメディア NI 6544/6545/6547/6548 デバイス スナップ式のフェライトビーズ(2x)(NI 製品番号 711627-01) フェライトを使用した高周波エミッションへの対策ドキュメント NI PXIe-6544/6545/6547/6548 スタートアップガイド | © National Instruments | 3 環境を整える NI 6544/6545/6547/6548 を使用する環境が次の仕様を満たしていることを確認します。 PXI Express モジュール 動作環境 ...................................................................................... 0~55℃(IEC 60068-2-1 および IEC 60068-2-2 周囲温度範囲 に準拠して試験済み。 MIL-PRF-28800FClass 3 最低温度制限値およ び MIL-PRF-28800FClass 2 最高温度制限値の 範囲内。) ...................................................................................... 相対湿度範囲 10~90%、結露なきこと(IEC 60068-2-56 に 従って試験済み。) ................................................................................................ 最大使用高度 2,000 m(800 mbar)(周囲温度 25℃時) ................................................................................................ 2 汚染度 室内使用のみ。 ソフトウェアをインストールする NI のソフトウェアをコンピュータにインストールするには、管理者権限を持っている 必要があります。 1. LabVIEW または LabWindows™/CVI™ などの ADE をインストールします。 ドライバソフトウェアメディアをコンピュータに挿入します。インストーラが自 動的に起動します。 2. インストールウィンドウが開かない場合は、ドライブを開き、ドライブをダブル クリックして、autorun.exe をダブルクリックします。 インストール画面の指示に従います。 3. メモ Windows ではアクセス/セキュリティメッセージが表示される場 合があります。画面の指示に従って、インストールを完了します。 インストールが完了したら、再起動、シャットダウン、または後で再起動するか どうかを尋ねるダイアログボックスで再起動を選択します。 4. NI Script Editor NI Script Editor は、波形生成操作のリンクおよびループの作成を支援します。 NI Script Editor は、NI-HSDIO のインストール時にインストールされます。詳細につい ては、NI Script Editor を起動して、ツールバーから Help→NI Script Editor Help を選択 してください。 4 | ni.com | NI PXIe-6544/6545/6547/6548 スタートアップガイド NI Digital Waveform Editor NI Digital Waveform Editor(NI DWE)を使用すると、デジタルテストベクトルを作成、 編集、インポートできます。 メモ NI DWE を使用する場合は、NI-HSDIO をインストールした後でインス トールします。 NI 6544/6545/6547/6548 を取り付ける 1. 2. 3. 4. 5. 注意 ESD や汚れによる破損を避けるために、デバイスを取り扱う際には、 デバイスの端や金属ブラケット部分以外には触れないでください。 モジュールを取り付ける前に、AC 電源がシャーシに接続されていることを確認 します。 モジュールを取り付けている間に、AC 電源コードがシャーシを接地して、シャー シを電気的破損から保護します。 シャーシの電源を切断します。 取り付け前に、シャーシバックプレーン上のスロットを検査して曲がったピンや 破損しているピンがないかどうか調べます。バックプレーンに損傷がある場合、 モジュールを挿入しないでください。 モジュールのフロントパネルにあるすべての取り付けネジから黒色のゴム製ネジ カバーを取り外します。 シャーシでサポートされているスロットを特定します。次の図は、スロットタイ プを表す記号を示しています。 図 1. シャーシ互換性記号 NI PXIe-1062Q 1 1. PXI Express システムコントローラスロット 2. PXI 周辺スロット 2 3 4 5 4. PXI Express システムタイミングスロット 5. PXI Express 周辺スロット 3. PXI Express ハイブリッド周辺スロット 6. 7. 8. NI 6544/6545/6547/6548 モジュールは、PXI Express 周辺スロット、PXI Express ハイ ブリッド周辺スロット、PXI Express システムタイミングスロットに取り付けるこ とができます。 静電気を放電するため、シャーシの金属部分に触れます。 着脱ハンドルがラッチされていない状態(下向き)になっていることを確認しま す。 モジュールの縁をシャーシの上下にあるモジュールガイドに配置します。デバイ スがスロットに完全に挿入されるまで押し込みます。 NI PXIe-6544/6545/6547/6548 スタートアップガイド | © National Instruments | 5 図 2. モジュールの取り付け 1 NI PX Ie -10 75 2 3 1. シャーシ 2. ハードウェアモジュール 3. 脱着ハンドル(下向き、ラッチされていない状態) 脱着ハンドルを引き上げてモジュールを固定します。 10. デバイスのフロントパネルを、シャーシのフロントパネルのマウントレールにネ ジで固定します。 9. メモ 上下の取り付けネジを締めることで機械的機構が安定し、またフ ロントパネルとシャーシも電気的に接続します。これにより信号整合性 と電磁性能が向上します。 11. フィラーパネルまたはスロットブロッカーですべての空のスロットを塞いで、冷 却のための通気を最大限に確保します。 12. シャーシの電源を投入します。 信号を接続する NI 6544/6545/6547/6548 フロントパネル NI 6544/6545/6547/6548 フロントパネルには、次の接続が装備されています。 • SMA コネクタ(CLK IN、PFI 0、CLK OUT)3 つ • 6 DIGITAL DATA & CONTROL または DDC という名前の 68 ピン VHDCI コネクタ、1 つ | ni.com | NI PXIe-6544/6545/6547/6548 スタートアップガイド 図 3. NI 6544/6545/6547/6548 フロントパネルの VHDCI コネクタピン配列 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 DIO 30 GND DIO 28 GND DIO 26 GND DIO 24 GND DIO 22 GND DIO 20 GND DIO 18 GND DIO 16 GND DIO 14 RESERVED DIO 12 GND DIO 10 GND DIO 8 GND DIO 6 RESERVED DIO 4 GND DIO 2 PFI 2 DIO 0 GND STROBE GND NI PXIe-654X ACCESS ACTIVE CLK IN PFI 0 CLK OUT DIGITAL DATA & CONTROL DIO 31 GND DIO 29 GND DIO 27 GND DIO 25 RESERVED DIO 23 GND DIO 21 GND DIO 19 GND DIO 17 GND DIO 15 GND DIO 13 GND DIO 11 GND DIO 9 GND DIO 7 PFI 1 DIO 5 GND DIO 3 PFI 3 DIO 1 GND DDC CLK OUT GND 表 1. NI 6544/6545/6547/6548 DDC コネクタピン ピン 信号名 信号タイプ 信号の説明 33 DDC_CLK OUT 制御 サンプルクロックがエクスポート される出力端子。 67 STROBE 制御 ダイナミック集録で使用可能な外 部サンプルクロックソースの端 子。 1, 3, 5, 7, 9, 11, 13, 15, 17, 19, 21, 23, 25, 27, 29, 31, 35, 37, 39, 41, 43, 45, 47, 49, 51, 53, 55, 57, 59, 61, 63, 65 DIO<0..31> データ 双方向デジタル I/O データチャン ネル、0~31。 NI PXIe-6544/6545/6547/6548 スタートアップガイド | © National Instruments | 7 表 1. NI 6544/6545/6547/6548 DDC コネクタピン (続き) ピン 信号名 信号タイプ 信号の説明 26, 30, 64 PFI(プログラム可 制御 能関数インタ フェース)<1..3> 外部トリガ用のデバイスへの入力 端子、またはイベント用のデバイ スからの出力端子。 2, 4, 6, 10, 12, 14, 16, 18, 20, 22, 24, 28, 32, 34, 36, 38, 40, 42, 44, 46, 48, 50, 54, 56, 58, 62, 66 GND グランド 信号用接地基準。 8, 52, 60 予約済み N/A これらの端子は、今後の使用のた めに予約されています。これらの ピンに接続しないでください。 表 2. NI 6544/6545/6547/6548 SMA コネクタ コネクタ 信号名 信号タイ プ 説明 CLK IN 基準クロッ ク入力 制御 PLL に使用される外部基準クロック、またはダイナ ミック生成または集録に使用される外部サンプル クロックの端子。 PFI 0 PFI 0 制御 スタティック I/O、外部トリガ、またはイベント用 のデバイスからの出力端子用のデバイスへの単一 入力端子。信号電圧レベルについては、デバイス の仕様を確認してください。 制御 エクスポートした PLL 基準クロック、またはエク スポートしたサンプルクロックの端子。 CLK OUT 基準クロッ ク出力 表 3. ACTIVE LED インジケータ 色 OFF 説明 デバイスがアームまたはトリガされていない状態。 オレンジ デバイスがアームされ、開始トリガを待機している状態。ダイナミック集 録操作を実行すると、デバイスがプレトリガサンプルを集録する場合があ ります。 8 | ni.com | NI PXIe-6544/6545/6547/6548 スタートアップガイド 表 3. ACTIVE LED インジケータ (続き) 色 説明 緑 デバイスが開始トリガを受信した状態。 赤 エラー状態。 表 4. ACCESS LED インジケータ 色 OFF 説明 デバイスの準備ができていない状態。 オレンジ ソフトウェアがデバイスにアクセスしている状態。 緑 赤 デバイスがプログラミング可能な状態。 「niHSDIO セルフテスト」VI の実行時、または「niHSDIO_self_test」 関数の呼び出しでエラーが発生した状態。 ケーブル接続に関する注意事項 DDC コネクタ用ケーブル 注意 デジタルデータおよび制御(DDC)コネクタにケーブルが接続すると きに、指定された EMC のパフォーマンスを確保するには、出荷キットに同梱 されている 2 つのフェライトビーズ(NI 製品番号 711627-01)を取り付けま す。ケーブルの両端のコネクタにできるだけ近い位置にそれぞれフェライト ビーズを 1 つ配置します。 注意 指定された EMC のパフォーマンスを確保するには、シールドケーブル およびアクセサリを必ず使用してください。非シールドケーブルまたはアク セサリを使用する場合は、適切に設計されたシールド付き入力/出力ポートが 装備され、シールドケーブルで製品に接続されたシールドケースに取り付け てください。非シールドケーブルまたはアクセサリが適切に取り付けおよび シールドされていない場合、この製品の EMC 仕様は保証されません。 NI 6544/6545/6547/6548 のデジタルデータおよび制御(DDC)コネクタに接続するに は、次のケーブルの 1 つを使用します。 • NI 6544/6545/6547/6548 シングルエンドシールドケーブル、各信号用に別々のマイ • クロ同軸 50 Ω ライン NI 6544/6545/6547/6548 シングルエンド非シールドデジタルケーブル NI PXIe-6544/6545/6547/6548 スタートアップガイド | © National Instruments | 9 • NI 6544/6545/6547/6548 低漏電シールドケーブル。電流漏れが問題になる場合は、 このケーブルを使用します。 NI 6544/6545/6547/6548 フライングリードシールドケーブル 図 4. シングルエンドのフライングリードケーブルのパーツ配置図 • 1 2 3 1. リード線ペア 2. 取り外し可能なスリーブ 3. 68 ピン VHDCI コネクタ メモ 信号の反射、オーバーシュート、アンダーシュートによる不適切な測 定を防ぐために、ケーブルは常に正しく終端する必要があります。信号終端 の詳細については、『NI デジタル波形発生器/アナライザヘルプ』を参照して ください。 アクセサリを接続する • デバイスの DDC コネクタにアクセスする、デバイスの DIO チャンネルを終端す る、または回路の試作および DUT のテスト用のプラットフォームを開発するに は、NI CB-2162 シングルエンドデジタル I/O アクセサリを接続します。NI CB-2162 を NI 6544/6545/6547/6548 に接続する方法は、次の図を参照してください。 注意 指定された EMC のパフォーマンスを確保するには、シールドケー ブルおよびアクセサリを必ず使用してください。非シールドケーブルま たはアクセサリを使用する場合は、適切に設計されたシールド付き入力/ 出力ポートが装備され、シールドケーブルで製品に接続されたシールド ケースに取り付けてください。非シールドケーブルまたはアクセサリが 10 | ni.com | NI PXIe-6544/6545/6547/6548 スタートアップガイド 適切に取り付けおよびシールドされていない場合、この製品の EMC 仕様 は保証されません。 図 5. NI CB-2162 と NI-HSDIO デバイスを接続する 2 NI PXI-6551 50 MHz Digital I/O ACCESS ACTIVE CLK IN PFI 0 DIGITAL DATA & CONTROL CLK OUT 1 3 1. NI-HSDIO デバイスを装着したシャーシ 2. NI SHC68-C68-D4 ケーブル 3. NI CB-2162 アクセサリ • テストおよびデバッグのために別のデバイスとインタフェースするには、 NI 6544/6545/6547/6548 に NI SMB-2163 アクセサリを接続します。NI SMB-2163 を NI 6544/6545/6547/6548 に接続する方法は、次の図を参照してください。 注意 指定された EMC のパフォーマンスを確保するには、シールドケー ブルおよびアクセサリを必ず使用してください。非シールドケーブルま たはアクセサリを使用する場合は、適切に設計されたシールド付き入力/ 出力ポートが装備され、シールドケーブルで製品に接続されたシールド ケースに取り付けてください。非シールドケーブルまたはアクセサリが NI PXIe-6544/6545/6547/6548 スタートアップガイド | © National Instruments | 11 適切に取り付けおよびシールドされていない場合、この製品の EMC 仕様 は保証されません。 図 6. NI SMB-2163 と NI-HSDIO デバイスを接続する NI PXI-6551 50 MHz Digital I/O ACCESS ACTIVE CLK IN PFI 0 DIGIDIGITAL DATA & CONTROL CLK OUT 1 2 3 1. NI-HSDIO デバイスを装着したシャーシ 2. NI SMB-2163 アクセサリ 3. NI SHC68-C68-D4 ケーブル カスタムアクセサリを接続する 注意 指定された EMC のパフォーマンスを確保するには、シールドケーブル およびアクセサリを必ず使用してください。非シールドケーブルまたはアク セサリを使用する場合は、適切に設計されたシールド付き入力/出力ポートが 装備され、シールドケーブルで製品に接続されたシールドケースに取り付け てください。非シールドケーブルまたはアクセサリが適切に取り付けおよび シールドされていない場合、この製品の EMC 仕様は保証されません。 多くの一般的な NI デジタル波形発生器/アナライザのアプリケーションでは、検査対 象デバイス(DUT)の信号にアクセスするためにカスタムアクセサリを作成する必要 があります。 NI 6544/6545/6547/6548 の VHDCI DDC コネクタにカスタムアクセサリを接続す るには、NI から VHDCI ケーブル用メイトコネクタを購入します。 詳細については、ni.com/jp/info で「rdinwa」と入力すると表示される『VHDCI コネクタを使用した NI デジタル波形発生器/アナライザとのインタフェース』ア プリケーションノートを参照してください。 一般的なアプリケーションの配線に関する注意事項 ダイナミック生成配線に関する注意事項 12 | ni.com | NI PXIe-6544/6545/6547/6548 スタートアップガイド 検査対象デバイス(DUT)の負荷によっては、ダイナミック生成中に最適な信号品質 を得るために、出力先に並列終端抵抗を追加する必要がある場合もあります。 信号終 端については、 『NI デジタル波形発生器/アナライザヘルプ』を参照してください。 次 の図は、NI 6544/6545/6547/6548 が、インピーダンスの一致したシステムを経由して データを生成する方法を示しています。 図 7. ダイナミック生成の機能図 RS RT 3 2 1 4 3. 50 Ω ケーブル 4. 検査対象デバイス(DUT) 1. NI-HSDIO デバイス 2. 50 Ω ソースインピーダンス(Rs) ダイナミック集録配線に関する注意事項 ダイナミック集録時に信号反射を最小限に抑えて最適な信号品質を維持するために、 信号を生成する検査対象デバイス(DUT)を 50 Ω にできるだけ近いソースインピーダ ンスで整合させる必要があります。次の図は、NI 6544/6545/6547/6548 が一致したイン ピーダンスを介してデータを集録する方法を示しています。サポートされている入力 インピーダンス(RT)については、デバイスの仕様書を参照してください。 図 8. ダイナミック集録の機能図 RT RS 2 1 3 4 1. NI-HSDIO デバイス 2. 50 Ω ケーブル 3. 50 Ω ソースインピーダンス(Rs) 4. 検査対象デバイス(DUT) NI 6544/6545/6547/6548 を MAX で構成する Measurement & Automation Explorer(MAX)を使用すると、お使いの NI ハードウェア を構成できます。MAX はデバイスがシステムにどのように接続し、構成されているか NI PXIe-6544/6545/6547/6548 スタートアップガイド | © National Instruments | 13 についての情報を他のプログラムに通知します。MAX は NI-HSDIO のインストール時 に自動的にインストールされます。 1. MAX を起動します。 取り付けられているデバイスのリストを表示するには、ツリー構図でデバイスと インタフェースをダブルクリックします。 2. メモ LabVIEW Real-Time モジュールと一緒に NI 6544/6545/6547/6548 を 使用している場合は、リモートシステムを展開します。ターゲットの IP アドレスまたは名前を検索し、デバイスとインタフェースを展開します。 お使いのシャーシのツリー項目を展開します。 3. MAX はシャーシの下にすべての使用可能なデバイスのリストを表示します。デ フォルトのデバイス名は使用状況により異なります。 メモ お使いのデバイスがリストに表示されない場合、<F5>を押して取 り付けられているデバイスのリストを更新します。上記の手順を行って もデバイスが表示されない場合は、システムの電源を切り、デバイスが 適切に取り付けられているか確認した後、再度電源を投入します。 4. MAX によってハードウェアに割り当てられたデバイス識別子をメモします。 NI 6544/6545/6547/6548 をプログラミングする際に、この識別子を使用します。 5. 構成ツリーでデバイスを選択し、MAX ツールバーのセルフテストをクリックして セルフテストを実行します。 MAX のセルフテストでは、ハードウェアリソースの基本的確認を行います。 テストパネルを使用してデジタルデータを生成 する デバイスの構成を確認するには、NI 6544/6545/6547/6548 を使用して MAX のデバイス テストパネルで簡単なデジタルデータを生成します。 1. デバイスへの信号接続を解除します。 2. 適切なシャーシの下のデバイスを右クリックして、図に示されるテストパネルを 選択します。 3. ぺーンの端にあるダイナミックタブを選択します。 4. すべて選択をクリックして、チャンネルをすべて選択します。デジタル波形がグ ラフに表示されます。 5. テストパネルの左側にあるクロック周波数制御器に周波数を入力します。 6. クロック周波数制御器の下にある制御器に、生成電圧と集録電圧の値を入力しま す。HIGH と LOW の値を入力することで、デバイスのカスタムレベルを作成でき ます。 7. フィルパターンを選択します。次の図は、ウィンドウ内のパターン制御器および 信号の先頭の一部を示しています。 14 | ni.com | NI PXIe-6544/6545/6547/6548 スタートアップガイド メモ 「1 の進行」または「0 の進行」波形を生成する場合は、波形サイ ズを選択したチャンネル数の倍数に設定します。 8. 再生をクリックして、選択したチャンネルのグラフに表示される波形を生成しま す。デフォルトの生成オプションは「連続」ですが、この設定はグラフの下の制 御器を使用して切り替えることができます。 NI 6544/6545/6547/6548 のデータチャンネルは双方向なので、前のステップのよう にすべてのチャンネルでデータが連続生成される間に生成されるデータを集録で きます。 メモ デバイスの生成操作に関連するセットアップ/ホールド時間およ び伝搬遅延については、仕様書を参照してください。特定の周波数では、 DIGITAL DATA & CONTROL (DDC)コネクタにケーブルが接続されてい ない場合に、同じチャンネルでデータを生成すると、これらのタイミン グパラメータに違反し、サンプルデータが不正確になります。詳細につ いては、『NI デジタル波形発生器/アナライザヘルプ』を参照してくださ い。 テストパネルを使用してデジタルデータを集録 する デバイスの構成を確認するには、NI 6544/6545/6547/6548 を使用して MAX のデバイス テストパネルで簡単なデジタルデータを集録します。 1. 集録タブをクリックします。 2. 再生をクリックします。 デバイスは上記の手順で生成したデジタルデータを集録し、データはグラフに表 示されます。 3. 終了したら、閉じるをクリックします。 NI PXIe-6544/6545/6547/6548 スタートアップガイド | © National Instruments | 15 NI-HSDIO をプログラミングする データを生成または集録するために NI-HSDIO 計測器ドライバを使用して NI 6544/6545/6547/6548 をプログラミングする際、サポートされている ADE から選択 できます。 表 5. NI 6544/6545/6547/6548 プログラミングオプション アプリケー ションプログ ラミングイン タフェース (API) 場所 説明 NI-HSDIO 計 測器ドライ バ LabVIEW―LabVIEW 関数パレッ トの 測定 I/O→NI-HSDIO からア クセス。 NI-HSDIO は、デバイスハードウェア を構成および操作するとともに、 LabVIEW VI または LabWindows/CVI 関数を使用して基本的な波形生成と 集録を実行します。 C または LabWindows/CVI― す べてのプログラム→IVI Foundation→IVI→Drivers→ niHSDIO からアクセス。 NI-HSDIO C サンプルを変更して Microsoft Visual C/C++を使用したア ¥examples ディレクトリにある プリケーションを作成することがで サンプルを使用。 <NIDocDir> きます。NI-HSDIO サンプルをコ ピーして、パスおよびライブラリ は次のいずれかのディレクト ファイルを含むための必要なプロ リ。 • Windows 8/7/Vista―Users ジェクト設定を複製します。すべて の必要なインクルードファイル お ¥Public¥Documents ¥National Instruments よびライブラリファイルをプロジェ クトに手作業で追加する方法につい • Windows XP―Documents ては、『NI デジタル波形発生器/アナ and Settings¥All ライザヘルプ の「Microsoft Visual C Users¥Shared および C++でアプリケーションを作 Documents¥National 成する」トピックを参照してくださ Instruments い。 Microsoft Visual C/C++― <NIDocDir>¥NI-HSDIO NI-HSDIO サンプル プログラミングサンプルの場所は、次の表を参照してください。 16 | ni.com | NI PXIe-6544/6545/6547/6548 スタートアップガイド 表 6. NI-HSDIO サンプルの場所 アプリケーション開発環境 (ADE) 場所 LabVIEW または LabWindows/CVI LabVIEW または LabWindows/CVI で、ヘルプ→サンプルを 検索を選択し、 ハードウェア入力と出力→モジュール式 計測器に移動します。 ANSI C <NIDocDir>¥NI-HSDIO¥examples¥ディレクトリ。 <NIDocDir>は、次のディレクトリのいずれかです。 • Windows 8/7/Vista―Users¥Public¥Public Documents¥National Instruments • Windows XP― Documents and Settings¥All Users¥Shared Documents¥National Instruments トラブルシューティング トラブルシューティングの手順を実行した後も問題が解決しない場合は、NI の技術サ ポートまでお問い合わせいただくか、ウェブサイト ni.com/support を参照してくださ い。 MAX で NI 6544/6545/6547/6548 が表示されない場合 1. MAX のツリー構図で、デバイスとインタフェースをクリックします。 2. 取り付けられているデバイスのリストを表示するには、シャーシツリーを展開し、 <F5>を押してリストを更新します。 3. リストを更新してもいずれのモジュールも表示されない場合は、システムの電源 を切り、すべてのハードウェアが正しく取り付けられていることを確認し、シス テムを再起動します。 4. デバイスマネージャに移動します。 オペレーティング システム 説明 Windows 8 スタート画面を右クリックし、すべてのアプリ→コント ロールパネル→ハードウェアとサウンド→デバイスマネー ジャを選択します。 Windows 7 スタート →コントロールパネル →デバイスマネージャ を 選択します。 Windows Vista スタート →コントロールパネル →システムとメンテナン ス →デバイスマネージャ を選択します。 NI PXIe-6544/6545/6547/6548 スタートアップガイド | © National Instruments | 17 オペレーティング システム 説明 Windows XP スタート →コントロールパネル →システム →ハードウェ ア →デバイスマネージャ を選択します。 PXI コントローラをお使いの場合、National Instruments の項目がシステムデバイ スのリストに表示されていることを確認します。エラー状態がリストに表示され ているときは、NI-HSDIO の再インストールとデバイスの再取り付けを行います。 MXI コントローラをお使いの場合、PCI-to-PCI Bridge を右クリックし、ショート カットメニューからプロパティを選択して、ブリッジが有効になっていることを 確認します。 5. モジュールがセルフテストで不合格になる 1. コンピュータを再起動します。 2. MAX を起動し、再度セルフテストを実行します。 3. シャーシの電源を切断します。 4. 不合格になったモジュールを異なるスロットに再取り付けします。 5. シャーシの電源を投入します。 6. 再度セルフテストを実行します。 シャーシの電源を投入しても ACCESS LED が点灯しな い LED は、MAX でのデバイスの構成が完了しないと点灯しないことがあります。継続す る前に、MAX で NI 6544/6545/6547/6548 が表示されるか確認してください。 PXI Express シャーシの電源を投入しても ACCESS LED が点灯しない場合は、PXI Express の電源レール、ハードウェアモジュール、LED のいずれかに問題がある可能性があり ます。 1. 注意 外部信号は、NI 6544/6545/6547/6548 の電源が投入されているとき にのみ接続します。デバイスに電源が投入されていない状態で外部信号 を接続すると、破損の原因になります。 PXI Express モジュールのフロントパネルへの信号接続をすべて取り外します。 2. NI 6544/6545/6547/6548 からすべてのフロントパネルの接続を外します。 3. PXI Express シャーシの電源を切断します。 4. PXI Express シャーシからモジュールを取り外して、破損がないか確認します。損 傷したデバイスは絶対に使用しないでください。 5. モジュールを取り外した PXI Express シャーシの異なるスロットにモジュールと 取り付けます。 6. PXI Express シャーシの電源を投入します。 7. デバイスが MAX で表示されることを確認します。 18 | ni.com | NI PXIe-6544/6545/6547/6548 スタートアップガイド 8. MAX でデバイスをリセットし、セルフテストを実行します。 それでも ACCESS LED が点灯せず、不合格状態が継続する場合は、NI 技術サポートま でお問い合わせいただくか、ウェブサイト ni.com/support を参照してください。 その他のガイドとヘルプ 次の図は、NI 6544/6545/6547/6548 を使用してアプリケーションを開発する際に役立つ その他のドキュメントとリソースを示しています。 ハードウェアキットから オンラインで ni.com/manuals から NI サンプルファインダから 探す 学ぶ 作る 用途に適したアプリケーション 開発環境(ADE) デバイス仕様を基にした ハードウェア機能 アプリケーションプログラミング インタフェース(API)を使用した カスタムアプリケーション LabVIEWスタートアップ ガイド デバイスの仕様* Getting Started with LabWindows/CVI NI デジタル波形発生器/ アナライザヘルプ* NI-HSDIO計測器ドライバ NI-HSDIOサンプル* NI デジタル波形発生器/ アナライザヘルプ* 調べる ni.comから最新の情報を入手 サポート 高速デジタルI/O サービス ni.com/support ni.com/highspeeddigitalio/ ni.com/services NI コミュニティ ni.com/community *これらは、ドライバソフトウェアによってもインストールされます。 世界各地でのサポートおよびサービス 技術サポートリソースの一覧は、ナショナルインスツルメンツのウェブサイトでご覧 いただけます。ni.com/support では、トラブルシューティングやアプリケーション開 発のセルフヘルプリソースから、ナショナルインスツルメンツのアプリケーションエ ンジニアの E メール/電話の連絡先まで、あらゆるリソースを参照できます。 ni.com/services からは、NI インストールサービス、修理、保証期間延長、その他の サービスをご利用いただけます。 NI PXIe-6544/6545/6547/6548 スタートアップガイド | © National Instruments | 19 ナショナルインスツルメンツ製品は、ni.com/register で登録できます。製品を登録す ると、技術サポートをより簡単に受けることができ、NI から重要な最新情報を確実に 受けることができます。 適合宣言(Doc)とは、その会社の自己適合宣言を用いた、さまざまな欧州閣僚理事 会指令への適合の宣言のことです。この制度により、電磁両立性(EMC)に対するユー ザ保護や製品の安全性に関する情報が提供されます。ご使用の製品の適合宣言は、 ni.com/certification(英語)から入手できます。ご使用の製品でキャリブレーションが サポートされている場合、ni.com/calibration からその製品の Calibration Certificate (英語)を入手してご利用になることもできます。 ナショナルインスツルメンツ米国本社の所在地は、11500 North Mopac Expressway, Austin, Texas, 78759-3504 です。ナショナルインスツルメンツのオフィスは世界各地に あります。日本国内でのサポートについては、ni.com/support でサポートリクエスト を作成するか、0120-527196(フリーダイヤル)または 03-5472-2970(大代表)までお 電話ください。各支社のウェブサイトには、弊社ウェブサイトの Worldwide Offices セ クション(ni.com/niglobal(英語))からアクセスできます。各支社のサイトでは、お 問い合わせの連絡先、サポート電話番号、電子メールアドレス、現行のイベント等に 関する最新情報を提供しています。 National Instruments の商標については、ni.com/trademarks に掲載されている「NI Trademarks and Logo Guidelines」をご覧 ください。本文書中に記載されたその他の製品名及び企業名は、それぞれの企業の商標又は商号です。National Instruments の製 品を保護する特許については、ソフトウェアで参照できる特許情報(ヘルプ→特許)、メディアに含まれている patents.txt ファイル、又は ni.com/patents からアクセスできる National Instruments Patent Notice(英語)のうち、該当するリソースか ら参照してください。エンドユーザ使用許諾契約(EULA)及び他社製品の法的注意事項はご使用の NI 製品の Readme ファイル にあります。ナショナルインスツルメンツの輸出関連法規遵守に対する方針について、また必要な HTS コード、ECCN(Export Control Classification Number)、その他の輸出入に関する情報の取得方法については、「輸出関連法規の遵守に関する情報」 (ni.com/legal/jp/export-compliance)を参照してください。NI は、本書に記載の情報の正確性について、一切の明示又は 黙示の保証を行わず、技術的な誤りについて一切の責任を負いません。米国政府のお客様へ: 本書に含まれているデータは、民間 企業の費用により作成されており、民間機関用の連邦調達規則 52.227-14 と軍事機関用の国防省連邦調達規則補足 252.227-7014 及び 252.227-7015 に基づく限定権利及び制約付データ権利の条項の適用を受けます。 © 2004—2015 National Instruments. All rights reserved. 375089A-01 2015 年 06 月
© Copyright 2025 ExpyDoc