Certified Passive House Component Fixed glazing Pazen Fenster+

Passive House Institute
Dr. Wolfgang Feist
64283 Darmstadt
GERMANY
Certified Passive House Component
for cold climates; valid until 31.12.2015
Category:
Manufacturer:
Product name:
Fixed glazing
Pazen Fenster+Technik GmbH
54516 Wittlich, GERMANY
ENERsign plus
0,08239
This certificate was awarded based
on the following criteria:
Passive House
Efficiency Class
Given a Ug value of 0.52 W/(m²K) and a window size of
1.23 m by 1.48 m,
UW
=
0.60
phA
advanced
component
W/(m²K) ≤ 0.60 W/(m²K)
Taking into account the installation based thermal bridges and
provided that the installation is, with regard to the thermal bridges,
equal or better than shown in the data sheet, the window meets
the following criterion.
U W,installed
phB
basic
component
≤ 0.65 W/(m²K)
phC
certifiable
component
Thermal data
Spacer
Bottom
Side/top
Uf-value
Width
[W/(m²K)]
[mm]
0.58
0.58
94
94
Ψg
fRsi=0.25
[W/(mK)]
[-]
SWISSP. Ultimate PU*
0.023
0.023
0.78
*Spacers of lower thermal quality, especially those made of aluminium, lead to significantly higher thermal losses and lower
temperature factors.
For further information, please see the data sheet
www.passivehouse.com
0772fx02
not suitable for
Passive
Houses
Data Sheet
Pazen Fenster+Technik GmbH, ENERsign plus
Manufacturer
Pazen Fenster+Technik GmbH
Dr. Oetker Straße 28, 54516 Wittlich, GERMANY
Tel.: + 49 (0)6571 95398 0
Email: [email protected], www.enersign.com
o
20 C
o
18 C
o
16 C
o
14 C
o
12 C
o
10 C
o
8 C
o
6 C
o
4 C
o
2 C
o
0 C
o
-2 C
o
-4 C
o
-6 C
o
-8 C
o
-10 C
Bottom section
Isothermal
Description
Aluminium cladded timber frame (0,11 W/(mK)), insulated by XPS-Foam (0,028 W/(mK)). The glazing is carried by
ENERcell (0,06 W/(mK)).
Pane thickness: 50 mm (4/18/6/18/4), rebate depth: 17 mm, spacer: SWISSPACER Ultimate with polyurethane as
secondary seal
Thermal data for the window frame
Spacer
Bottom
Side/Top
Flying Mullion
Uf-value
Width
Ψg
fRsi=0.25
[W/(m²K)]
[mm]
[W/(mK)]
[-]
0.58
0.58
0.63
94
94
112
SWISSP. Ultimate PU*
0.023
0.78
0.023
0.022
0.77
Flying mullion
* Spacers of lower thermal quality lead to higher thermal losses and lower glass edge temperatures.
www.passivehouse.com
Passive House Institute Page 1/2
Data Sheet
Pazen Fenster+Technik GmbH, ENERsign plus
Installation
Installation based thermal bridge Ψinstal.
[W/(mK)]
[W/(m²K)]
Insulated
formwork
blocks
[W/(mK)]
Timber
construction
wall
Position
Bottom
Side/Top
UW,instal.
EIFS
in Passive House suitable walls
0.009
-0.003
0.59
0.019
0.012
0.64
0.008
0.001
0.60
Explanatory notes
The window U-values were calculated based on a 1.23 m by 1.48 m window Ug = 0.52 W/(m²K).
If better other is used, the window U-values chances as follows:
U Glazing
Ug [W/(m²K)]
0.60
0.43
0.35
U Window
UW [W/(m²K)]
0.65
0.53
0.47
Depending on the thermal losses through opaque elements, transparent components are categorised according to
efficency classes. These thermal losses include the losses through the frame, the frame width, the thermal bridge
at the glass edge as well as the length of the glass edge. Certificates for arctic regions are too valid vor cold,
certificates for cold regions are too valid for cool, temperate zones.
Please ask the manufacturer for a detailed report containing all calculations and results.
For further information, please visit www.passivehouse.com or www.passipedia.org.
www.passivehouse.com
Passive House Institute Page 2/2